• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 32
  • 30
  • 29
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Investigação das propriedades físicas de metais moleculares, da terra preta de índio e o parâmetro de Grüneisen fonônico /

Mello, Isys Fernandes January 2019 (has links)
Orientador: Valdeci Pereira Mariano de Souza / Resumo: Neste trabalho de Mestrado foram explorados aspectos fundamentais da Fı́sica do Estado Sólido através de três frentes de pesquisa. A primeira e principal frente de pesquisa é referente ao estudo da chamada fase ferroelétrica de Mott-Hubbard nos condutores moleculares orgânicos quase-unidimensionais da famı́lia (TMTTF)2X, onde TMTTF é a molécula tetrametiltetratiafulvaleno e X é um contra-ânion monovalente. Tal investigação foi realizada através de experimentos de constante dielétrica e o denominado Positive Up Negative Down (PUND) a qual permite obter informações acerca da polarização elétrica intrı́nseca de um sistema ferroelétrico. Os resultados mostram a anisotropia para a constante dielétrica e a presença de polarização intrı́nseca abaixo de Tco . Uma segunda frente é relacionada às oscilações de cargas em sólidos onde foi investigado o quão suscetı́vel tais oscilações são à variações de volume. Esta análise foi realizada através do cálculo do parâmetro de Grüneisen fonônico para a frequência de plasma. Os cálculos realizados mostram que as oscilações de carga são fortemente influenciadas por variações de volume e, consequentemente de pressão. A última frente de estudo é relacionada ao solo da Amazônia conhecido como Terra Preta de Índio para o qual foram realizadas medidas de ressonância paramagnética eletrônica. Esta permitiu obter informações acerca de propriedades conectadas ao spin eletrônico do sistema. As medidas mostram um possı́vel ordenamento ferromagnético na T... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this Master thesis, fundamental aspects of Solid State Physics were explored through three research topics. The first and main research topic is the investigation of the so-called Mott-Hubbard ferroelectric phase in quasi-one-dimensional organic molecular conductors of the (TMTTF)2X family, where TMTTF is the tetramethyltetrathiafulvalene molecule and X is a monovalent counter-anion. This investigation was carried out through dielectric constant and the so-called Positive Up Negative Down (PUND) experiments, which enable to obtain physical information about the intrinsic electric polarization of a ferroelectric system. Our results reveled the anisotropy of the the dielectric constant and the presence of intrinsic electric polarization below Tco . The second topic is related to the charge oscillations in solids, the so-called plasma frequency, where it was investigated how susceptible such frequency is to volume variations. This analysis was performed by calculating the phononic Grüneisen parameter for the plasma frequency. The calculations reveled that the charge oscillations are strongly influenced by changes in volume and, consequently, of pressure. The last research topic is related to the Amazonian soil known as Terra Preta de Índio, for which electron spin resonance measurements were performed. This allowed to obtain information about properties connected to the electronic spin of the system. The measurements reveled a possible ferromagnetic ordering in TPI, which may... (Complete abstract click electronic access below) / Mestre
22

Desempenho do reflectômetro no domínio do tempo na detecção de variações de umidade do solo. / Performance of a time domain reflectometer in the detection of soil moisture variations.

Joaquim Júnior, Gilberto Oliveira 21 July 2003 (has links)
O objetivo do trabalho foi avaliar o desempenho do reflectômetro no domínio do tempo (TDR) comparativamente ao tensiômetro com manômetro de mercúrio (considerado como instrumento padrão), dando-se ênfase na sensibilidade de detecção de variações na umidade do solo sob condições de molhamento e secagem. Foi instalado um experimento em um solo classificado como Nitossolo Vermelho distrófico latossólico de textura muito argilosa, localizado próximo ao Posto Meteorológico do Departamento de Ciências Exatas, ESALQ/USP, Piracicaba (SP), Brasil, 22 o 42’ 30’’ de latitude sul e 47 o 38’ 00’’ de longitude oeste. Com dados de um ensaio de determinação da condutividade hidráulica do solo pelo Método do Perfil Instantâneo, de um período de secagem e de inundações intermitentes do solo, analisou-se a concordância entre a constante dielétrica obtido pelo TDR e o potencial matricial da água no solo obtido pelo tensiômetro, além dos valores de umidade volumétrica obtidos pelas mesmas técnicas. Concluiu-se que o desempenho do TDR foi superior ao do tensiômetro sob condições de secagem do solo e na detecção de variações de umidade. / The performance of a time domain-reflectometer (TDR) was compared with a mercury tensiometer (considered to be the norm), emphasizing the detection of variations in soil water content under wetting and drying conditions (as in instantaneous profile method to determine soil hydraulic conductivity). An experiment was performed in a Nitossolo Vermelho distrófico latossólico argiloso (Brazilian classification system), close to the meteorological observatory of the ESALQ/USP, Piracicaba (SP), Brazil, latitude 22 o 42’30’’ S, longitude 47 o 38’00’’ W. Data of matric potential, dieletric constant and water content during a dry period and water application were analyzed. The TDR cable tester was better than the tensiometer to detect the soil moisture variation.
23

Interpretação dos resultados de ensaios TDR para a determinação do teor de umidade dos solos / Interpretation of TDR test results for determining the moisture content of soil

Valdivia Calderón, Victor Jack 20 April 2010 (has links)
Este trabalho de pesquisa apresenta uma nova abordagem para calibrar uma sonda helicoidal TDR, usada para medir o teor de umidade do solo. Foi empregada uma aproximação tomando em consideração a interpretação física dos valores de constantes dielétricas. As equações de calibração foram determinadas mediante um modelo dielétrico misto, quais relacionam a constante dielétrica da mistura multifase com a constante dielétrica e frações de volumes dessas componentes. Ensaios realizados em laboratório permitirem o desenvolvimento de duas equações de calibração para a avaliação de teor de umidade volumétrico e gravimétrico dos solos. A calibração foi executada com medições de constante dielétrica em diferentes líquidos e solos, usando uma sonda convencional TDR e a sonda helicoidal TDR. As leituras realizadas com as duas sondas foram depois comparadas. O modelo dielétrico das duas fases permitiu descrever a contribuição dos materiais dielétricos do corpo da sonda helicoidal e os materiais investigados. Mostrou-se que o conhecimento das características físicas e geométricas da sonda TDR usada nos ensaios é de crucial para garantir a qualidade das constantes dielétricas lidas, e conseqüentemente a determinação do teor de umidade in situ. / The objective of this work was to calibrate a coiled TDR probe used to measure the water content of soil. It was used an approach that takes into account a physical interpretation of the values of the dielectric constants. The calibration equations were determined by means of a mixed dielectric model, which relates the dielectric constant of a multi-phase mixture with the dielectric constants and volume fractions of its components. Tests carried out in the laboratory allowed development of two calibration equations for the assessment of the volumetric and gravimetric soil water content. Calibration was performed with measurements of dielectric constants in different liquids and soils, using a conventional TDR probe and a coiled TDR. The readings performed with the two probes were then compared. The dielectric model of two phases permitted describing the contribution of the dielectric material of the body of the probe coil and the materials investigated. It has been shown that knowledge of the physical and geometrical characteristics of the TDR probe used in the tests is crucial for the quality of the dielectric constant readings, and consequently the determination of water content in situ.
24

Metodologia fototérmica aplicada na caracterização de materiais pastosos / Photothermal methodology applied in the characterization of pasty materials

Albuquerque, Marcos Lázaro de Souza 26 September 2018 (has links)
Orientadores: Edson Correa da Silva e Antonio Manoel Mansanares / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin. / Made available in DSpace on 2018-09-26T17:40:21Z (GMT). No. of bitstreams: 1 Albuquerque_MarcosLazarodeSouza_D.pdf: 2664850 bytes, checksum: 47305c651cc9350b772372c3f4181f3e (MD5) Previous issue date: 2008 / Resumo: Neste trabalho desenvolveu-se um experimento de detecção fototémica com dois sensores piroelétricos em uma célula capacitiva que permite a realização de medidas térmicas e elétricas em materiais pastosos em função da temperatura.A célula idealizada para medidas elétricas e térmicas é um capacitor plano de placas paralelas capaz de obter das amostras investigadas os parâmetros de efusividade térmica, difusividade térmica,condutividade térmica e constante dielétrica relativa,simultaneamente,além de detectar transições,em especial fusão.A célula capacitiva fotopiroelétrica é composta por dois sensores piroelétricos entre os quais a amostra é posicionada.Um elemento Peltier associado a um termistor é utilizado para o controle de temperatura.Incide sobre a célula um feixe de radiação eletromagnética oriunda de uma fonte Laser Ar + (514,5 nm ).A radiação modulada atinge diretamente um dos sensores que é opaco e que está em contato térmico com a amostra.O calor gerado no primeiro sensor se propaga, então,pelo sistema amostra-segundo sensor gerando sinais nos dois sensores que são amplificados em amplitude e fase por dois amplificadores seletivos.Ao mesmo tempo,os sinais elétricos da célula capacitiva são registrados por uma ponte RCL operando em 2 kHz.A aquisição de dados dos sinais térmicos é procedida em programa escrito em ambiente LabView para varredura de freqüência de 0 a 100 Hz.Preliminarmente,medidas foram realizadas com margarina e mostraram o potencial da metodologia na verificação do comportamento térmico e elétrico de materiais pastosos.Foi investigado um conjunto de oito amostras constituídas por pares de componentes em proporções e métodos de sínteses diferentes de três tipos de óleos vegetais:algodão,palma e soja.Para a obtenção da constante dielétrica relativa da amostra,o valor da capacitância da mesma foi normalizado pelo valor de capacitância da célula vazia (dielétrico o ar).Modelos para a interpretação dos dados experimentais das medidas térmicas e elétricas foram desenvolvidos.Os gráficos dos sinais de amplitude e fase térmicas detectados pelos sensores foram plotados em função da freqüência de modulação e ajustados pelas equações teóricas dos sensores para a obtenção dos parâmetros térmicos.Foram obtidos valores dos parâmetros efusividade térmica, difusividade térmica,condutividade térmica e constante dielétrica relativa das oito amostras investigadas, além da identificação da região do ponto de fusão das mesmas.Os resultados mostraram que a célula desenvolvida neste trabalho para a aplicação em materiais pastosos pode identificar a região do ponto de fusão,obter os parâmetros térmicos e a constante dielétrica relativa das amostras investigadas / Abstract: This work consists in the development of an experimental apparatus of photopyroelectric detection using two pyroelectric sensors in a capacitive cell which allows the accomplishment of electrical and thermal measurements of pasty materials as a function of the temperature.The idealized cell for electrical and thermal measurements is based in a parallel plane-plate capacitor whose metallic plates are the internal surfaces of the pyroelectric sensors.The system is capable to obtain thermal parameters like effusivity, diffusivity and conductivity,and electric parameters like the dielectric constant for the investigated samples.The identification of the melt point region from either the thermal measurements of the photopyroelectric signal amplitude and phase or the electrical measurements is possible as well.The capacitive photopyroelectric cell is composed by two pyroelectric sensors.An insulator support is used to accommodate the samples which are placed between the sensors.An aluminum piece hold all parts of the cell;one Peltier element is associated with a termistor to control the temperature.An eletromagnetic radiation beam from a Ar + laser incides on the cell and is modulated by an acoustic-optic modulator.The modulated radiation reaches one of the sensors which is opaque and in contact with the sample.Two L ck-in amplifiers amplify the signals originated in each sensor due to the propagation of heat while the electrical signals are registered by an automatic RCL bridge operating at 2 kHz.For data acquisition a Labview language computer software was used allowing to frequency scanning from 0 to 100 Hz. Preliminary experiments were carried out with margarine and showed the methodology pontential in the verification of the thermal and electrical behavior of pasty materials.It was investigated a set of eight samples formed by different compositions of three vegetable oils:cotton,palm and soy in different proportions and within two synthesis methods (basic mixture of intersterification).The sample capacitance was normalized by the empty cell to obtain the relative dielectric constant of the sample.The models for the thermal and electrical data interpretation were developed.For the thermal case simulations were proceeded for a basic oil in order to verify the model.The graphs for thermal amplitude and phase from both sensors were plotted as a function of modulation frequency from which the thermal properties were obtained by fitting the model equations.The values of thermal effusivity,thermal diffusivity, thermal conductivity and relative dielectric constant were obtained for the samples and the transition melting region as well.The results have shown that the cell here developed is very suitable for the determination of thermal and electrical properties of pasty samples and the determination of transition as well. / Doutorado / Física Geral / Doutor em Ciências
25

Avaliação de uma sonda TDR helicoidal para a estimativa do teor de umidade de solos em campo e laboratório / Evaluation of a helicoidal TDR probe to estimate the soil water content in laboratory and in situ

Assis, Cleber Decarli de 09 May 2008 (has links)
Este trabalho de pesquisa apresenta a avaliação de uma sonda TDR helicoidal para estimar o teor de umidade dos solos, em diferentes profundidades, através da técnica da reflectometria no domínio do tempo (TDR). Essa sonda, desenvolvida especificamente para esse fim, foi devidamente calibrada em laboratório para diferentes tipos de solo. O processo de calibração consistiu na determinação da constante dielétrica aparente (Ka) e condutividade elétrica volumétrica (ECb) de um mesmo solo com diferentes teores de umidade. Posteriormente foram buscadas correlações entre Ka e o teor de umidade gravimétrico (w), obtido em estufa. São propostas correlações entre w e Ka, entre w e \'KA POT. 1/2\' e entre teor de umidade volumétrico (\'teta\') e Ka. Também foram consideradas as correlações propostas por Yu e Drnevich (2004), visando estimar também a massa específica seca dos solos. Foram realizados ensaios de campo para a validação das equações de calibração. Os valores dos teores de umidade estimados através da técnica da reflectometria no domínio do tempo, tanto em laboratório como em campo, foram comparados com os valores de teor de umidade obtidos com o método da estufa. Com base nos resultados foram determinados os erros referentes às calibrações. Nos ensaios de campo, os teores de umidade obtidos através da correlação entre w e \'KA POT. 1/2\' apresentaram melhores resultados, quando comparados com aqueles estimados com as outras correlações. Pelos resultados obtidos conclui-se que a técnica TDR é uma alternativa viável para a estimativa em campo do teor de umidade em grandes profundidades. / In this work is presented the evaluation of a recently developed helicoidal probe used for estimating the soil water content through the time domain technology (TDR). This probe has been calibrated in laboratory for different types of soils. The calibration process consisted in assessing the values of the apparent dielectric constant (Ka) and the bulk electric conductivity (ECb) of a specific soil at different levels of water content (w). Subsequently, correlations between the apparent dielectric constant and the water content have been established. The same has done with the bulk electric conductivity. Correlations between Ka and w, \'KA POT. 1/2\' and w, \'teta\' (volumetric water content) and Ka have been proposed. Also, the correlations proposed by Yu and Drnevich (2004) have been considered. To validate the proposed correlations, tests using the helicoidal probe were performed in the field. Estimated values of field water content, using the TDR technology have been compared to the correspondent oven water content values. Based on these comparisons, errors regarding the calibrations have been calculated. In the field tests, the correlations between \'KA POT. 1/2\' and w have presented more accurate results than those obtained with the other correlations. Experimental results have shown that the TDR technology for estimating water content at different depths in the field is feasible and expedite.
26

O uso do georadar na determinação de parâmetros da estrutura de pavimentos flexíveis / The use of ground penetrating radar in the determination of the structure of flexible pavements

Faria, Sandro Henrique de 29 June 2010 (has links)
Made available in DSpace on 2015-03-26T13:27:54Z (GMT). No. of bitstreams: 1 texto completo.pdf: 4751258 bytes, checksum: 0e480b21213f063f9d31d1243a36f77a (MD5) Previous issue date: 2010-06-29 / This paper aims to analyze the Ground Penetrating RADAR as tool in the determination of the thickness of the layers of the flexible road pavement of automatic way and the density of the asphalt layer supported by integrated testing of GPR and geotechnical data. The first experiment was conducted at the Presidente Dutra highway (BR116), Pirai - RJ, while the data for the second experiment were obtained from the BR040 highway, Sete Lagoas - MG. In order to achieve the objectives of this study, two methodologies were developed: the first one, directed to the identification of the thicknesses of the layers of flexible pavements of automated way; the second one, focused on determining the density of the layer of asphalt surfaces. The first methodology showed promising results, once it presented good classification results for the classes 1 (off-set) and 3 (macadam), however, was confusion between the "blocks" classified for the classes 2 (asphalt) and 4 (subgrade). A possible alternative, for improvement, would be: to use other texture extractor of the wavelet transform family; to use another type of interpolation, using a that better represents the trends of the coefficients to be generated the surface; to increase the number of training and testing samples, or even to use another type of classifier, such as Artificial Neural Networks. However, this is a field that is worth being investigated more deeply, since the results proved to be significant. The second methodology, regarding the correlation of the density of the asphalt layer through the dielectric value, measured by means an ground coupled antenna, of 1,6GHz, using the technique of the reflection, it presented satisfactory values in spite of the few sampling points, showing to be a good alternative to determine indirectly the density of the asphalt layer and for future works in the area. / Este trabalho tem o propósito de analisar o desempenho do RADAR de penetração no solo como ferramenta na determinação das espessuras das camadas do pavimento rodoviário flexível de maneira automática e a densidade da camada de revestimento apoiado em testes integrados de GPR e dados geotécnicos. O primeiro experimento foi realizado na rodovia Presidente Dutra (BR116), município de Piraí - RJ, em quanto os dados para o segundo experimento foram obtidos na rodovia BR040, município de Sete Lagoas - MG. Para atingir os objetivos do trabalho foram elaboradas duas metodologias: a primeira delas, direcionada à identificação das espessuras das camadas de pavimentos flexíveis de modo automatizado; a segunda, voltada para a determinação da densidade da camada de revestimento asfáltico. A primeira metodologia apresentou, de uma maneira geral, resultados promissores, uma vez que foram bons os resultados de classificação para as classes 1 (off-set) e 3 (macadame), no entanto, houve confusão entre os “blocos” classificados para as classes 2 (revestimento) e 4 (subleito). Uma possível alternativa para a melhoria dos resultados seria mudar o extrator de textura utilizado (transformada wavelet), valeria apena testar outros extratores da família wavelet; outra opção seria utilizar outro tipo de interpolador, usando um que pegue mais as tendências dos coeficientes ao se gerar a superfície; também seria interessante aumentar o número de amostras de treinamento e teste, ou até mesmo, utilizar outro tipo de classificador, como por exemplo, Redes Neurais Artificiais. Todavia, esse é um campo que vale ser pesquisado mais profundamente, uma vez que os resultados alcançados se mostraram esperançosos. A segunda metodologia, referente à correlação da densidade da camada de revestimento através do valor dielétrico, medido por meio de uma antena de contato no solo, de 1,6 GHz, utilizando a técnica da reflexão, apresentou valores satisfatórios apesar dos poucos pontos amostrados, mostrando ser uma boa escolha para se determinar a densidade da camada de revestimento de maneira indireta e para trabalhos futuros na área.
27

Interpretação dos resultados de ensaios TDR para a determinação do teor de umidade dos solos / Interpretation of TDR test results for determining the moisture content of soil

Victor Jack Valdivia Calderón 20 April 2010 (has links)
Este trabalho de pesquisa apresenta uma nova abordagem para calibrar uma sonda helicoidal TDR, usada para medir o teor de umidade do solo. Foi empregada uma aproximação tomando em consideração a interpretação física dos valores de constantes dielétricas. As equações de calibração foram determinadas mediante um modelo dielétrico misto, quais relacionam a constante dielétrica da mistura multifase com a constante dielétrica e frações de volumes dessas componentes. Ensaios realizados em laboratório permitirem o desenvolvimento de duas equações de calibração para a avaliação de teor de umidade volumétrico e gravimétrico dos solos. A calibração foi executada com medições de constante dielétrica em diferentes líquidos e solos, usando uma sonda convencional TDR e a sonda helicoidal TDR. As leituras realizadas com as duas sondas foram depois comparadas. O modelo dielétrico das duas fases permitiu descrever a contribuição dos materiais dielétricos do corpo da sonda helicoidal e os materiais investigados. Mostrou-se que o conhecimento das características físicas e geométricas da sonda TDR usada nos ensaios é de crucial para garantir a qualidade das constantes dielétricas lidas, e conseqüentemente a determinação do teor de umidade in situ. / The objective of this work was to calibrate a coiled TDR probe used to measure the water content of soil. It was used an approach that takes into account a physical interpretation of the values of the dielectric constants. The calibration equations were determined by means of a mixed dielectric model, which relates the dielectric constant of a multi-phase mixture with the dielectric constants and volume fractions of its components. Tests carried out in the laboratory allowed development of two calibration equations for the assessment of the volumetric and gravimetric soil water content. Calibration was performed with measurements of dielectric constants in different liquids and soils, using a conventional TDR probe and a coiled TDR. The readings performed with the two probes were then compared. The dielectric model of two phases permitted describing the contribution of the dielectric material of the body of the probe coil and the materials investigated. It has been shown that knowledge of the physical and geometrical characteristics of the TDR probe used in the tests is crucial for the quality of the dielectric constant readings, and consequently the determination of water content in situ.
28

Desempenho do reflectômetro no domínio do tempo na detecção de variações de umidade do solo. / Performance of a time domain reflectometer in the detection of soil moisture variations.

Gilberto Oliveira Joaquim Júnior 21 July 2003 (has links)
O objetivo do trabalho foi avaliar o desempenho do reflectômetro no domínio do tempo (TDR) comparativamente ao tensiômetro com manômetro de mercúrio (considerado como instrumento padrão), dando-se ênfase na sensibilidade de detecção de variações na umidade do solo sob condições de molhamento e secagem. Foi instalado um experimento em um solo classificado como Nitossolo Vermelho distrófico latossólico de textura muito argilosa, localizado próximo ao Posto Meteorológico do Departamento de Ciências Exatas, ESALQ/USP, Piracicaba (SP), Brasil, 22 o 42’ 30’’ de latitude sul e 47 o 38’ 00’’ de longitude oeste. Com dados de um ensaio de determinação da condutividade hidráulica do solo pelo Método do Perfil Instantâneo, de um período de secagem e de inundações intermitentes do solo, analisou-se a concordância entre a constante dielétrica obtido pelo TDR e o potencial matricial da água no solo obtido pelo tensiômetro, além dos valores de umidade volumétrica obtidos pelas mesmas técnicas. Concluiu-se que o desempenho do TDR foi superior ao do tensiômetro sob condições de secagem do solo e na detecção de variações de umidade. / The performance of a time domain-reflectometer (TDR) was compared with a mercury tensiometer (considered to be the norm), emphasizing the detection of variations in soil water content under wetting and drying conditions (as in instantaneous profile method to determine soil hydraulic conductivity). An experiment was performed in a Nitossolo Vermelho distrófico latossólico argiloso (Brazilian classification system), close to the meteorological observatory of the ESALQ/USP, Piracicaba (SP), Brazil, latitude 22 o 42’30’’ S, longitude 47 o 38’00’’ W. Data of matric potential, dieletric constant and water content during a dry period and water application were analyzed. The TDR cable tester was better than the tensiometer to detect the soil moisture variation.
29

SENSOR CAPACITIVO PARA MONITORAMENTO DO TEOR DE ÁLCOOL ETÍLICO ANIDRO COMBUSTÍVEL (AEAC) EM AMOSTRAS DE GASOLINA COMERCIAL / CAPACITIVE SENSOR FOR MONITORING OF THE LEVEL OF ANHYDROUS ETHYL ALCOHOL FUEL (AEAF) IN SAMPLES OF COMMERCIAL GASOLINE

Souza, Darlan Carvalho de 12 July 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:45Z (GMT). No. of bitstreams: 1 Dissertacao Darlan.pdf: 2834733 bytes, checksum: f7d35c098bddf8713fbdbe733565fdef (MD5) Previous issue date: 2013-07-12 / During several years, adulterated gasoline has been commercialized across all Brazil. Often such product has higher alcohol content, water traces or organic solvents insertion (e.g. paint thinner and/or turpentine). The use of nonconforming gasoline, in the short and long terms, has several problems for consumers, for the vehicle and the environment. Thus, this work aims to propose a low cost technique for analyzing gasoline blends, in relation to its oxygenated addition. Both capacitance and dielectric constant (relative permittivity) were determined by means of a high precision LCR-meter, using a metal concentric sensor. Therefore, gasoline blends were prepared by adding 16, 18, 20, 22, 24, 26, 28 and 30% of AEAF to the initial petroleum-based fuel and their dielectric constants were measured at frequencies of 0.3, 0.4, 0.5 and 0.6 kHz. The same samples were analyzed by the reference method, the Test Tube Test. According to statistical modeling, the frequency of 0.6 kHz showed the most significant results for all samples. The results show that at 95% confidence level, there is no significant difference between the two methods, indicating a good correlation between the proposed method and then standard one. However, when the density was used as evaluating parameter, instead of dielectric constant, for the same samples, a substantial discrepancy of the obtained values were observe, suggest a low sensibility of such methodology. / Vários são os casos de não conformidade da gasolina comercial, principalmente pelo excesso de etanol, ou ainda pela adição de água ou solventes leves como thinner e aguarrás. O uso de gasolina não conforme, a curto e longo prazo, traz diversos problemas para o consumidor, para o veículo e ao meio ambiente. No presente trabalho estudou-se a qualidade da gasolina tipo C, comercializada nos postos revendedores de combustível, no que diz respeito à concentração de álcool etílico anidro combustível (AEAC). Análises estas, realizadas através de medidas de constante dielétrica (permissividade relativa) utilizando sensor capacitivo. Misturas de gasolina A e AEAC foram preparadas nas concentrações de 16, 18, 20, 22, 24, 26, 28 e 30% de AEAC, sendo suas constantes dielétricas medidas nas frequências de 0,3; 0,4; 0,5 e 0,6 kHz. Utilizando tratamento estatístico verificou-se que a frequência de 0,6 kHz apresentou resultados mais significativos para leitura de AEAC das misturas preparadas. Nessa mesma frequência, amostras comerciais de gasolina e amostras de gasolinas não conformes contaminadas com gasolina A e AEAC foram submetidas à análise. As mesmas amostras foram submetidas à análise pelo método de referência, o Teste da Proveta. Os resultados obtidos mostram que, no nível de confiança de 95%, não há diferença significativa entre os dois métodos. Medidas de massas específicas também foram realizadas com as misturas gasolina A e AEAC (16 a 30%) para modelamento de curva de calibração com finalidade de determinar o teor de AEAC e posterior comparação com os resultados oriundos da constante dielétrica e do teste da proveta, entretanto, o método não se mostrou eficiente para análise das amostras de gasolina comercial e amostras de gasolinas não conformes analisadas.
30

Avaliação de uma sonda TDR helicoidal para a estimativa do teor de umidade de solos em campo e laboratório / Evaluation of a helicoidal TDR probe to estimate the soil water content in laboratory and in situ

Cleber Decarli de Assis 09 May 2008 (has links)
Este trabalho de pesquisa apresenta a avaliação de uma sonda TDR helicoidal para estimar o teor de umidade dos solos, em diferentes profundidades, através da técnica da reflectometria no domínio do tempo (TDR). Essa sonda, desenvolvida especificamente para esse fim, foi devidamente calibrada em laboratório para diferentes tipos de solo. O processo de calibração consistiu na determinação da constante dielétrica aparente (Ka) e condutividade elétrica volumétrica (ECb) de um mesmo solo com diferentes teores de umidade. Posteriormente foram buscadas correlações entre Ka e o teor de umidade gravimétrico (w), obtido em estufa. São propostas correlações entre w e Ka, entre w e \'KA POT. 1/2\' e entre teor de umidade volumétrico (\'teta\') e Ka. Também foram consideradas as correlações propostas por Yu e Drnevich (2004), visando estimar também a massa específica seca dos solos. Foram realizados ensaios de campo para a validação das equações de calibração. Os valores dos teores de umidade estimados através da técnica da reflectometria no domínio do tempo, tanto em laboratório como em campo, foram comparados com os valores de teor de umidade obtidos com o método da estufa. Com base nos resultados foram determinados os erros referentes às calibrações. Nos ensaios de campo, os teores de umidade obtidos através da correlação entre w e \'KA POT. 1/2\' apresentaram melhores resultados, quando comparados com aqueles estimados com as outras correlações. Pelos resultados obtidos conclui-se que a técnica TDR é uma alternativa viável para a estimativa em campo do teor de umidade em grandes profundidades. / In this work is presented the evaluation of a recently developed helicoidal probe used for estimating the soil water content through the time domain technology (TDR). This probe has been calibrated in laboratory for different types of soils. The calibration process consisted in assessing the values of the apparent dielectric constant (Ka) and the bulk electric conductivity (ECb) of a specific soil at different levels of water content (w). Subsequently, correlations between the apparent dielectric constant and the water content have been established. The same has done with the bulk electric conductivity. Correlations between Ka and w, \'KA POT. 1/2\' and w, \'teta\' (volumetric water content) and Ka have been proposed. Also, the correlations proposed by Yu and Drnevich (2004) have been considered. To validate the proposed correlations, tests using the helicoidal probe were performed in the field. Estimated values of field water content, using the TDR technology have been compared to the correspondent oven water content values. Based on these comparisons, errors regarding the calibrations have been calculated. In the field tests, the correlations between \'KA POT. 1/2\' and w have presented more accurate results than those obtained with the other correlations. Experimental results have shown that the TDR technology for estimating water content at different depths in the field is feasible and expedite.

Page generated in 0.0787 seconds