• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contaminação Microbiana em Placas de Armazenamento de Fósforo Intrabucais

Souza, Tricia Murielly Pereira de 31 January 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-08T19:17:15Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO TRICIA MURIELLY PEREIRA ANDRADE DE SOUZA.pdf: 2322643 bytes, checksum: 4725a9d74b61857b6e6c6446d355c50c (MD5) / Made available in DSpace on 2015-04-08T19:17:15Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO TRICIA MURIELLY PEREIRA ANDRADE DE SOUZA.pdf: 2322643 bytes, checksum: 4725a9d74b61857b6e6c6446d355c50c (MD5) Previous issue date: 2014 / O objetivo neste estudo foi analisar contaminação microbiana em placas de armazenamento de fósforo intrabucais utilizadas em duas clínicas privadas de Radiologia Odontológica. A amostra foi composta por 50 placas de fósforo: 44 do grupo teste, sendo 14 da clínica A (sistema Digora Optime®), e 30 da clínica B (sistema ScanX®); e 6 do grupo controle, sendo 3 placas nunca utilizadas de cada sistema. Os protocolos de controle de infecção adotados pelas clínicas no uso das placas de fósforo não incluíam o uso de luvas nas etapas de processamento e embalagem das placas, mas apresentavam o uso de uma barreira plástica adicional para a realização de técnicas intrabucais. Para a coleta do material microbiano, Swabs umedecidos foram esfregados na superfície das placas, e transferidos para tubos contendo 2ml de solução salina (solução-mãe). Esses tubos foram agitados e seu conteúdo diluído seriadamente. As diluições foram inoculadas em placas de Petri contendo Ágar Mueller Hinton (MHA), as quais foram incubadas a 37ºC/48 h para contagem de Unidades Formadoras de Colônias (UFC). Adicionou-se 1,5 ml da solução-mãe a 1,5 ml de caldo BHI (Brain Heart Infusion), e incubou-se a 37°C/48 h. Então, as soluções foram semeadas em MHA, Ágar Mitis Salivarius (MSA), Ágar Sabouraud Dextrose (SDA), e Ágar Sal Manitol (SMA). Incubou-se a 37°C/48 h, e observou-se o crescimento microbiano. Na clínica A, 50% das placas de fósforo apresentaram contaminação, e na clínica B 73,3%. Houve crescimento em SMA para 100% das placas contaminadas da clínica A, e 86,3% da clínica B, indicando presença de Staphylococcus sp. Em MSA, houve crescimento para uma das placas de fósforo da clínica A, sugestivo de Streptococcus sp. Não houve crescimento em SDA, demonstrando ausência de fungos. Verificou-se crescimento de UFC para 28,5% das placas contaminadas da clínica A (26.4 UFC/placa), e 27,2% da clínica B (de 26.4 a 80.0 UFC/placa). Não foi observada contaminação nas placas dos sistemas Scan X e Digora Optime, usadas como controle. Conclui-se que há risco de contaminação cruzada por placas de armazenamento de fósforo, pois a maioria das placas analisadas apresentou-se contaminada, principalmente por bactérias do gênero Staphylococcus. Quantitativamente, essa contaminação ocorreu em baixos níveis, sendo oriunda da manipulação das placas, já que o uso de uma segunda barreira plástica diminui o risco de contaminação das placas por microrganismos da cavidade bucal.
2

Avaliação do design higiênico de equipamentos que contribuem para a contaminação de carcaças na 1ª etapa de abate de suínos / Evaluation of hygienic design of equipments which contribute to pork cascasses contamination in a slaughterhouse

Mariot, Roberta Fogliatto January 2010 (has links)
O objetivo deste trabalho foi avaliar a contaminação microbiológica e o isolamento de Salmonella spp. em diferentes estágios da 1° etapa de um abatedouro frigorífico, além de aspectos importantes do design higiênico de equipamentos que demonstraram contribuir para a contaminação das carcaças. Para a avaliação microbiológica das carcaças suínas foram estimadas as contagens de microrganismos heterotróficos totais (CT) e a incidência de Salmonella spp. em quatro locais da superfície (papada, lombo, barriga e pernil) de 239 carcaças processadas em uma indústria exportadora Abatedoura frigorífica de suínos (3200 animais por dia). Equipamentos que demonstraram incrementar as CT e o isolamento de Salmonella spp. nas carcaças suínas avaliadas foram submetidos a uma lista de verificação dos requisitos do design higiênico (113 itens). A superfície em contato com as carcaças das polidoras foram os chicotes, confeccionados por elastômeros, avaliados quanto à formação e remoção de biofilme em dois diferentes tipos de elastômeros e analisados quanto a sua topografia, através de Microscopia Eletrônica de Varredura (MEV). Reduções significativas (p<0,05) foram observadas nas CT de 99,85% após a escaldagem e 99,8% e 94,36%, em ambas as chamuscagens, respectivamente. Incrementos significativos (p<0,05) foram encontrados nas depilagem e em ambos os polimentos de carcaças. Na incidência de Salmonella spp. os resultados encontrados foram semelhantes; Salmonella spp. não foi detectada após a escalda e após os chamuscadores. Entretanto houve um aumento na incidência após a depiladeira e em ambas as polidoras. Estes resultados demonstraram que a depiladeira e a polidora aumentaram as contaminações microbiológicas das carcaças suínas, portanto foram diagnosticadas através de uma lista de verificação do design higiênico e demonstraram que mais de 50% dos requisitos não foram atendidos por estas máquinas, corroborando com a avaliação microbiológica. A formação e remoção de biofilme na superfície dos diferentes elastômeros, utilizados na construção dos chicotes e avaliados neste estudo, demonstraram que a maior aderência ocorreu no tempo de 180 min em ambos os materiais avaliados e que o elastômero termoplástico poliéster (ETP) demonstrou aderir menos em relação ao confeccionado de borracha natural vulcanizada. Em relação à remoção de biofilme, ambos os tempos de contato com o ácido peracético a 1% testados (1 e 10 min) demonstraram ser eficientes na remoção ou eliminação de Salmonella spp. dos corpos de prova. Na avaliação da topografia da superfície dos diferentes elastômeros, através da MEV, a borracha natural vulcanizada demonstrou possuir uma rugosidade mais elevada quando comparada ao ETP, corroborando com os resultados encontrados na aderência. / The aim of this study was to evaluate the microbial contamination, the incidence of Salmonella spp. at various stages of the pork slaughterlines and aspects of hygienic design from equipments which contributed with the pork carcass contamination. To evaluate the microbial contamination and the incidence of Salmonella spp. at various stages of the pork slaughterlines, the total counts (TC) and the incidence of Salmonella spp. were estimated in four surface locations (Ham, belly, loin and neck) on 239 pork carcasses processed through a big exporter pig-slaughtering plant (3200 animals per day). In order to evaluate important aspects of design hygienic from equipments that contributed with pork carcass contamination, the hygienic design requirements list verification (113 items) were used to do a diagnosis, to verify the biofilm formation and removal in different elastomers used in polishing food area and to compare both surface in scanning electron microscope. A significant (p <0.05) increase was found in dehairing and in both polishing stages. Similar results to Salmonella incidence were observed; the incidence increased to 16.67% from 0% on dehairing and then to 20% after the first polishing and increased 10.5% from 0% after the second polishing. When dehairing and polishing machines were diagnosed with hygienic design requirements list verification both demonstrated not attended more than 50 % of the hygienic design requirements, both machines shown poor welding, dead spaces where dirt can be retained and resulting in food contamination, for example. The biofilm formation and removal demonstrated significant difference between the time of contact with the bacterial solution (1, 30, 60 and 180 min) and the time of 180 min demonstrated greater adherence when compared to other contact time. Elastomer Termoplastic Polyester (ETP) demonstrated less adherence when compared with natural volcanic rubber. In the biofilm removals were used 180 min in contact with the bacterial suspension and 1 and 10 min in contact with the peracetic acid 1% were not observed microbial growth in both elastomers. When were compared both surface in scanning electron microscope, natural volcanic rubber demonstrated more roughness when compared with ETP.
3

Avaliação do design higiênico de equipamentos que contribuem para a contaminação de carcaças na 1ª etapa de abate de suínos / Evaluation of hygienic design of equipments which contribute to pork cascasses contamination in a slaughterhouse

Mariot, Roberta Fogliatto January 2010 (has links)
O objetivo deste trabalho foi avaliar a contaminação microbiológica e o isolamento de Salmonella spp. em diferentes estágios da 1° etapa de um abatedouro frigorífico, além de aspectos importantes do design higiênico de equipamentos que demonstraram contribuir para a contaminação das carcaças. Para a avaliação microbiológica das carcaças suínas foram estimadas as contagens de microrganismos heterotróficos totais (CT) e a incidência de Salmonella spp. em quatro locais da superfície (papada, lombo, barriga e pernil) de 239 carcaças processadas em uma indústria exportadora Abatedoura frigorífica de suínos (3200 animais por dia). Equipamentos que demonstraram incrementar as CT e o isolamento de Salmonella spp. nas carcaças suínas avaliadas foram submetidos a uma lista de verificação dos requisitos do design higiênico (113 itens). A superfície em contato com as carcaças das polidoras foram os chicotes, confeccionados por elastômeros, avaliados quanto à formação e remoção de biofilme em dois diferentes tipos de elastômeros e analisados quanto a sua topografia, através de Microscopia Eletrônica de Varredura (MEV). Reduções significativas (p<0,05) foram observadas nas CT de 99,85% após a escaldagem e 99,8% e 94,36%, em ambas as chamuscagens, respectivamente. Incrementos significativos (p<0,05) foram encontrados nas depilagem e em ambos os polimentos de carcaças. Na incidência de Salmonella spp. os resultados encontrados foram semelhantes; Salmonella spp. não foi detectada após a escalda e após os chamuscadores. Entretanto houve um aumento na incidência após a depiladeira e em ambas as polidoras. Estes resultados demonstraram que a depiladeira e a polidora aumentaram as contaminações microbiológicas das carcaças suínas, portanto foram diagnosticadas através de uma lista de verificação do design higiênico e demonstraram que mais de 50% dos requisitos não foram atendidos por estas máquinas, corroborando com a avaliação microbiológica. A formação e remoção de biofilme na superfície dos diferentes elastômeros, utilizados na construção dos chicotes e avaliados neste estudo, demonstraram que a maior aderência ocorreu no tempo de 180 min em ambos os materiais avaliados e que o elastômero termoplástico poliéster (ETP) demonstrou aderir menos em relação ao confeccionado de borracha natural vulcanizada. Em relação à remoção de biofilme, ambos os tempos de contato com o ácido peracético a 1% testados (1 e 10 min) demonstraram ser eficientes na remoção ou eliminação de Salmonella spp. dos corpos de prova. Na avaliação da topografia da superfície dos diferentes elastômeros, através da MEV, a borracha natural vulcanizada demonstrou possuir uma rugosidade mais elevada quando comparada ao ETP, corroborando com os resultados encontrados na aderência. / The aim of this study was to evaluate the microbial contamination, the incidence of Salmonella spp. at various stages of the pork slaughterlines and aspects of hygienic design from equipments which contributed with the pork carcass contamination. To evaluate the microbial contamination and the incidence of Salmonella spp. at various stages of the pork slaughterlines, the total counts (TC) and the incidence of Salmonella spp. were estimated in four surface locations (Ham, belly, loin and neck) on 239 pork carcasses processed through a big exporter pig-slaughtering plant (3200 animals per day). In order to evaluate important aspects of design hygienic from equipments that contributed with pork carcass contamination, the hygienic design requirements list verification (113 items) were used to do a diagnosis, to verify the biofilm formation and removal in different elastomers used in polishing food area and to compare both surface in scanning electron microscope. A significant (p <0.05) increase was found in dehairing and in both polishing stages. Similar results to Salmonella incidence were observed; the incidence increased to 16.67% from 0% on dehairing and then to 20% after the first polishing and increased 10.5% from 0% after the second polishing. When dehairing and polishing machines were diagnosed with hygienic design requirements list verification both demonstrated not attended more than 50 % of the hygienic design requirements, both machines shown poor welding, dead spaces where dirt can be retained and resulting in food contamination, for example. The biofilm formation and removal demonstrated significant difference between the time of contact with the bacterial solution (1, 30, 60 and 180 min) and the time of 180 min demonstrated greater adherence when compared to other contact time. Elastomer Termoplastic Polyester (ETP) demonstrated less adherence when compared with natural volcanic rubber. In the biofilm removals were used 180 min in contact with the bacterial suspension and 1 and 10 min in contact with the peracetic acid 1% were not observed microbial growth in both elastomers. When were compared both surface in scanning electron microscope, natural volcanic rubber demonstrated more roughness when compared with ETP.
4

Avaliação do design higiênico de equipamentos que contribuem para a contaminação de carcaças na 1ª etapa de abate de suínos / Evaluation of hygienic design of equipments which contribute to pork cascasses contamination in a slaughterhouse

Mariot, Roberta Fogliatto January 2010 (has links)
O objetivo deste trabalho foi avaliar a contaminação microbiológica e o isolamento de Salmonella spp. em diferentes estágios da 1° etapa de um abatedouro frigorífico, além de aspectos importantes do design higiênico de equipamentos que demonstraram contribuir para a contaminação das carcaças. Para a avaliação microbiológica das carcaças suínas foram estimadas as contagens de microrganismos heterotróficos totais (CT) e a incidência de Salmonella spp. em quatro locais da superfície (papada, lombo, barriga e pernil) de 239 carcaças processadas em uma indústria exportadora Abatedoura frigorífica de suínos (3200 animais por dia). Equipamentos que demonstraram incrementar as CT e o isolamento de Salmonella spp. nas carcaças suínas avaliadas foram submetidos a uma lista de verificação dos requisitos do design higiênico (113 itens). A superfície em contato com as carcaças das polidoras foram os chicotes, confeccionados por elastômeros, avaliados quanto à formação e remoção de biofilme em dois diferentes tipos de elastômeros e analisados quanto a sua topografia, através de Microscopia Eletrônica de Varredura (MEV). Reduções significativas (p<0,05) foram observadas nas CT de 99,85% após a escaldagem e 99,8% e 94,36%, em ambas as chamuscagens, respectivamente. Incrementos significativos (p<0,05) foram encontrados nas depilagem e em ambos os polimentos de carcaças. Na incidência de Salmonella spp. os resultados encontrados foram semelhantes; Salmonella spp. não foi detectada após a escalda e após os chamuscadores. Entretanto houve um aumento na incidência após a depiladeira e em ambas as polidoras. Estes resultados demonstraram que a depiladeira e a polidora aumentaram as contaminações microbiológicas das carcaças suínas, portanto foram diagnosticadas através de uma lista de verificação do design higiênico e demonstraram que mais de 50% dos requisitos não foram atendidos por estas máquinas, corroborando com a avaliação microbiológica. A formação e remoção de biofilme na superfície dos diferentes elastômeros, utilizados na construção dos chicotes e avaliados neste estudo, demonstraram que a maior aderência ocorreu no tempo de 180 min em ambos os materiais avaliados e que o elastômero termoplástico poliéster (ETP) demonstrou aderir menos em relação ao confeccionado de borracha natural vulcanizada. Em relação à remoção de biofilme, ambos os tempos de contato com o ácido peracético a 1% testados (1 e 10 min) demonstraram ser eficientes na remoção ou eliminação de Salmonella spp. dos corpos de prova. Na avaliação da topografia da superfície dos diferentes elastômeros, através da MEV, a borracha natural vulcanizada demonstrou possuir uma rugosidade mais elevada quando comparada ao ETP, corroborando com os resultados encontrados na aderência. / The aim of this study was to evaluate the microbial contamination, the incidence of Salmonella spp. at various stages of the pork slaughterlines and aspects of hygienic design from equipments which contributed with the pork carcass contamination. To evaluate the microbial contamination and the incidence of Salmonella spp. at various stages of the pork slaughterlines, the total counts (TC) and the incidence of Salmonella spp. were estimated in four surface locations (Ham, belly, loin and neck) on 239 pork carcasses processed through a big exporter pig-slaughtering plant (3200 animals per day). In order to evaluate important aspects of design hygienic from equipments that contributed with pork carcass contamination, the hygienic design requirements list verification (113 items) were used to do a diagnosis, to verify the biofilm formation and removal in different elastomers used in polishing food area and to compare both surface in scanning electron microscope. A significant (p <0.05) increase was found in dehairing and in both polishing stages. Similar results to Salmonella incidence were observed; the incidence increased to 16.67% from 0% on dehairing and then to 20% after the first polishing and increased 10.5% from 0% after the second polishing. When dehairing and polishing machines were diagnosed with hygienic design requirements list verification both demonstrated not attended more than 50 % of the hygienic design requirements, both machines shown poor welding, dead spaces where dirt can be retained and resulting in food contamination, for example. The biofilm formation and removal demonstrated significant difference between the time of contact with the bacterial solution (1, 30, 60 and 180 min) and the time of 180 min demonstrated greater adherence when compared to other contact time. Elastomer Termoplastic Polyester (ETP) demonstrated less adherence when compared with natural volcanic rubber. In the biofilm removals were used 180 min in contact with the bacterial suspension and 1 and 10 min in contact with the peracetic acid 1% were not observed microbial growth in both elastomers. When were compared both surface in scanning electron microscope, natural volcanic rubber demonstrated more roughness when compared with ETP.
5

Reanimador manual: quando trocar no mesmo paciente

Gomes, Giselle Pinheiro Lima Aires 31 March 2016 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2016-11-09T14:03:31Z No. of bitstreams: 2 Tese - Giselle Pinheiro Lima Aires Gomes - 2016.pdf: 3158182 bytes, checksum: ba9d36d200045df31c0cbd0972cc94a2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-11-10T17:49:41Z (GMT) No. of bitstreams: 2 Tese - Giselle Pinheiro Lima Aires Gomes - 2016.pdf: 3158182 bytes, checksum: ba9d36d200045df31c0cbd0972cc94a2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-11-10T17:49:41Z (GMT). No. of bitstreams: 2 Tese - Giselle Pinheiro Lima Aires Gomes - 2016.pdf: 3158182 bytes, checksum: ba9d36d200045df31c0cbd0972cc94a2 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-03-31 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / INTRODUCTION: The manual resuscitator is a widely used respiratory assist device that has been reported to be a reservoir and a source of contamination from various microorganisms. At present, there is no criteria to replacement of manual resuscitator when it is in successive use in the same patient. AIM: To evaluate the safest amount of time the manual resuscitator can be successively used in the same patient. METHODS: An open, prospective cohort study was conducted from October to November, 2014 using 30 patient connector valves from manual resuscitator devices obtained from Intensive Care Units of a general hospital located in a region north of Brazil. The samples were collected through swab friction on the manual resuscitator that was used by the same patient, at zero (ready use), 24 and 48 hours. Bacterial identification and antibiotic susceptibility were performed automatically (Vitek 2 Compact®). RESULTS: Of the 30 resuscitators evaluated, 20 (66.6%) were found to be contaminated. There was a significant difference between the microbial load on the manual resuscitators in use at zero and 24 hours (p = 0.03). Associated risk factors for the contamination of manual resuscitators identified were frequency and time of use. The presence of visible soil was not detected on 19 manual resuscitators in use, however, 95.0% were contaminated. The number of microorganisms isolated at zero, 24 and 48 hours were five, 11 and 24, respectively. Thirteen devices were contaminated with two or more bacterial species. Of the Gram-positive cocci, 38.9% (n = 18) were methicillin-resistant Staphylococcus aureus and 11.1% were methicillin-resistant coagulase-negative Staphylococcus, all were constitutive MLSB resistant. Of the Gram-negative rods (n = 36), Acinetobacter baumannii (36.1%), Pseudomonas aeruginosa (19.4%), Serratia marcescens (22.2%) and Proteus spp. (8.3%) dominated. Over 50% of these were resistant to carbapenems, second, third and fourth cephalosporins generations, and ampicillin/sulbactam. CONCLUSION: Manual resuscitators in successive use in the same patient were contaminated even in the absence of visible dirt. Multi- and extensively-resistant bacteria of clinical importance were also detected. Frequency and time of use were identified as risk factors in the contamination of manual resuscitators. The longer the time of use, the greater the number of contaminated resuscitators and bacterial species isolated. These results point to failures in reprocessing, and therefore highlights the importance of having thorough discussions among regulators about the recommendations for the reprocessing of semi-critical medical devices, especially, those for ventilatory assistance. Furthermore, the results highlight the need to replace manual resuscitators every 24 hours after use as a strategy for infection control and to minimize the risk of re-colonization or -infection of the respiratory tract. / INTRODUÇÃO: O reanimador manual é um dispositivo de assistência respiratória amplamente utilizado que tem sido reportado como reservatório e fonte de contaminação por diversos micro-organismos, e ainda não apresenta critérios definidos para a troca quando em uso sucessivo no mesmo paciente. OBJETIVO: Avaliar o tempo de uso seguro do reanimador manual em uso sucessivo no mesmo paciente. MÉTODO: Trata-se de uma coorte aberta prospectiva, realizada de outubro a novembro de 2014 em 30 válvulas do reanimador manual (conector do paciente) em Unidades de Tratamento Intensivo de um hospital geral da região Norte do Brasil. As amostras foram coletadas por meio de fricção de swab em reanimador manual em uso no mesmo paciente nos tempos zero (pronto uso), 24 e 48 horas. A identificação bacteriana e o antibiograma foram automatizados (Vitek 2 Compact®). RESULTADOS: Dos 30 reanimadores avaliados, 20 (66,6%) estavam contaminados. A carga microbiana entre os tempos zero e 24h de uso dos reanimadores manuais apresentou diferença estatística significativa (p=0,03). A frequência e o tempo de uso foram identificados como fatores de risco associados para a contaminação de reanimadores manuais em uso. Dos 19 reanimadores manuais avaliados como visivelmente limpos, 95,0% apresentaram contaminados. Foram isolados cinco, 11 e 24 tipos de micro-organismos nos tempos zero, 24 e 48 horas respectivamente. Treze dispositivos estavam contaminados por duas ou mais espécies bacterianas. Dentre os cocos gram-positivos (n=18), 38,9% eram Staphylococcus aureus resistentes à meticilina e 11,1% Staphylococcus coagulase negativos resistentes à meticilina, todos com resistência constitutiva ao grupo MLSB. Dentre os bastonetes gram-negativos (n=36), predominaram Acinetobacter baumannii (36,1%), Pseudomonas aeruginosa (19,4%), Serratia marcescens (22,2%) e Proteus spp. (8,3%). Mais de 50% destes apresentaram resistência aos carbapenens, cefalosporinas de segunda, terceira e quarta gerações, e ampicilina/sulbactam. CONCLUSÃO: Os reanimadores manuais em uso sucessivo no mesmo paciente estavam contaminados, mesmo na ausência de sujidade visível, sendo o tempo e a frequência de uso do dispositivo fatores de risco identificados. Bactérias multirresistentes e extensivamente resistentes de importância clínica foram detectadas. Quanto maior o tempo de uso, maior o número de reanimadores contaminados e de espécies bacterianas isoladas. Os resultados apontam para falhas no processamento, e indicam necessidade de discussão entre os órgãos regulamentadores sobre a recomendação para o processamento de produtos para a saúde semicríticos, em especial, os de assistência ventilatória e demonstram ainda a necessidade de troca do reanimador manual a cada 24 horas de uso, como estratégia primária para minimizar o risco de (re)colonização que poderá resultar em infecção do trato respiratório.

Page generated in 0.1072 seconds