• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 902
  • 582
  • 184
  • 96
  • 46
  • 42
  • 18
  • 18
  • 12
  • 11
  • 8
  • 8
  • 7
  • 7
  • 6
  • Tagged with
  • 2327
  • 775
  • 323
  • 322
  • 311
  • 235
  • 177
  • 148
  • 144
  • 140
  • 140
  • 135
  • 133
  • 123
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
671

Profiling of potential pathogens from Plankenburg river water used for the irrigation of fresh produce

Kikine, Tshepo Neo Ferdinard 12 1900 (has links)
Thesis (MSc Food Sc)--Stellenbosch University, 2011. / ENGLISH ABSTRACT: The increased consumption of fresh produce has been shown to be related to increases in foodborne disease outbreaks and these have in many cases been ascribed directly to carry-over of pathogens from contaminated irrigation water. In South Africa, rivers are the main source of irrigation water but many have been found to be unsuitable for irrigation of fresh produce because of the unacceptably high levels of faecal contamination. The main aim of this study was to do a baseline evaluation of the microbiological quality of the Plankenburg and Eerste Rivers and to determine which bacterial contaminants are present. Two sampling sites were selected for the Plankenburg (Plank-1 and -3) and one for the Eerste River (Eerste-1). The microbiological analysis included aerobic colony count (ACC), aerobic and anaerobic sporeformers, Staphylococcus, Salmonella, Listeria, enterococci, coliforms, faecal coliforms and E. coli using standard methods. The faecal contamination levels for both rivers exceeded the DWAF and WHO guidelines of <1 000 E. coli per 100 mL water for irrigation of fresh produce intended to be consumed raw. The Plankenburg River sites always had higher coliform contamination levels (1 200 - 13 000 000 MPN per 100 mL water) than the Eerste River site (230 - 79 000 MPN per 100 mL water). There was also a high incidence of index organisms including Salmonella, Staphylococcus, Listeria and endosporeformers. The isolation of intestinal enterococci suggested the presence of potential pathogens that can cause disease outbreaks. The baseline data also showed large variations in microbial loads over the 15 month study with the faecal coliform counts ranging for Plank-1 from 1 200 to 7 000 000 MPN.100mL-1, Plank-3 from 10 to 460 000 MPN.100mL-1 and Eerste-1 from 28 to 79 000 MPN.100mL-1. The water temperatures at all three sites ranged from 12.1° to 21.7°C with COD values in most cases below 100 mg.L-1. As the baseline study showed large variations in microbial loads over the 15 month study period an assessment using the Colilert-18 system of the weekly, daily and hourly variations, for 6 weeks over a period of 4 months was conducted at site Plank-2. This site was specifically used as it is an irrigation source point for nearby fresh produce farmers and is about 2 km further downstream from an informal settlement. The weekly variation trend for total coliforms (TC) showed a decrease over the entire sampling period with the highest count of 3 200 000 MPN.100 mL-1 during the warmer period. The E.coli (Ec) counts showed a similar trend with the highest count of 440 000 MPN.100 mL-1 also in March. The daily variation trends were the same for both the TC and Ec and counts found to increase from Monday to Thursday followed by a decrease to Sunday. The highest counts were on Thursday with average TC and Ec counts of 1 900 000 and 160 000 MPN.100 mL-1, respectively. The hourly variation trends were similar for both TC and Ec with counts increasing from 06h00 to 12h00 followed by a decrease to 18h00. The increases in TC and Ec counts found during the weekly, daily and hourly variation trend studies clearly suggests that the 15 month sampling that was done once a month on Mondays at 08h00 could be considered an underestimation of the contamination levels of the Plankenburg and Eerste Rivers. The overall weekly variation trend for the water temperature showed a decrease over the sampling period while the daily and hourly variation trends showed an increase from 06h00 to 18h00. The overall weekly trend for pH differed from that of the temperature with an increase over the sampling period. The analysis of covariance showed no correlation (p < 0.05) between the physico-chemical (temperature and pH) and the microbial variables (TC and Ec). Therefore it was concluded that temperature and pH had no direct impact on either the total coliform or E. coli counts. Both the Plankenburg and Eerste Rivers were found to be unsuitable for the irrigation of fresh produce intended to be consumed raw due to the high levels of faecal contamination that exceeded DWAF and WHO guidelines. Irrigation with such water could pose a health risk because of presence of potential pathogens that could be carried-over to fresh produce. / AFRIKAANSE OPSOMMING: Die toenemende gebruik van vars produkte hou direk verband met die toename in voedseloordraagbare siektes. Alte dikwels kan dit toegeskryf word aan die teenwoordigheid van patogene in besproeiingswater. In Suid Afrika is riviere die hoofbron van besproeiingswater maar dit is al gevind dat meeste ongeskik is vir gebruik as besproeïngsbron as gevolg van die onaanvaarbare hoe vlakke van fekale besmetting. Die hoofdoel van hierdie studie was om ‘n basislyn evaluasie van die mikrobiologiese kwaliteit van die Plankenburg en Eerste Riviere te doen en ook vas te stel watter bakteriese kontaminante teenwoordig is. Twee bemonsteringpunte is geselekteer vir die Plankenburg (Plank- 1 en -3) en een vir die Eerste Rivier (Eerste-1). Mikrobiologiese analises met standaard metodes het die volgende ingesluit: aërobe kolonie telings (AKT), aërobe en anaërobe spoorevormers, Staphylococcus, Salmonella, Listeria, enterococci, koliforms, fekale koliforms en E. coli met gebruik van standaard metode. Die fekale besmettingsvlakke vir beide riviere het die DWAF en WHO leistreep van <1 000 E. coli per 100 mL water vir besproeiing van vars produkte wat rou geëet kan word oorskry. Die Plankenburg Rivier bemonsteringspunte het in alle gevalle ‘n hoër kolivorm besmettingsvlak (1 200 - 13 000 000 MPN per 100 mL water) as die Eerste Rivier punt (230 - 79 000 MPN per 100 mL water) gehad. Daar was ook ‘n hoër voorkoms van indeksorganismes insluitend Salmonella, Staphylococcus, Listeria en endosporevormers. Die voorkoms van ingewand enterococci was ‘n addisionele aanduiding van die voorkoms van patogene wat ernstige gesondheidsrisikos vir die verbruiker kan inhou. Die basislyn data het groot variasies in die mikrobe vlakke oor die 15 maand van studie getoon. Die faecal koliforms vir Plank- 1 het gewissel van 1 200 tot 7 000 000 MPN.100mL-1, vir Plank-3 van 10 tot 460 000 MPN.100mL-1 en vir Eerste-1 van 28 tot 79 000 MPN.100mL-1. Die water temperature het gewissel van 12.1° tot 21.7°C met die CSB waardes in meeste gevalle minder as 100 mg.L-1. Aangesien daar sulke groot variasies in mikrobe ladings oor die 15 maande tydperk voorgekom het, is die Colilert-18 sisteem gebruik om die weeklikse, daaglikse en uurlikse variasies vas te stel vir 6 weke oor ‘n periode van 4 maande by die Plank-2 bemonsteringspunt. Daar is spesifiek op die bemonsteringspunt gefokus omdat dit as ‘n besproeiingsbron gebruik word deur groente produsente. Dit is ook gelee ongeveer 2 km stroomaf van ‘n informele nedersetting. Die weeklikse variasies in totaal koliforms (TC) het ‘n afname oor die hele bemonsteringsperiode getoon, met die hoogstes telling van 3 200 000 MPN.100 mL-1 gedurende die warmer tydperk. Die E.coli (Ec) tellings het ‘n soortgelyke neiging getoon, met die hoogste telling van 440 000 MPN.100 mL-1 ook in Maart. Die daaglikse neigings was dieselfde vir beide die TC en Ec en die tellings het vermeerder van Maandag tot Donderdag, met ‘n afname tot Sondag. Die hoogste telling was op Donderdag met gemiddelde TC and Ec tellings van 1 900 000 and 160 000 MPN.100 mL-1, respektiewelik. Die uurlikse variasie profiel was soortgelyk vir beide TC and Ec met tellings wat vermeerder het van 06h00 tot 12h00 gevolg deur ‘n afname tot 18h00. Die toename in TC en Ec getalle soos vasgestel gedurende die weeklikse, daaglikse en uurlikse variasie het duidelik getoon dat die bemonsterings wat een maal per maand op Maandae om 08h00 gedurende die 15 maande tydperk uitgevoer is, tot ‘n erg onderskatting van die besmettings vlakke in die Plankenburg en Eerste Riviere gelei het. Die algehele weeklikse variasies vir die water temperatuur het ‘n verlaging oor die bemonsteringstydperk getoon terwyl die daaglikse en uurlikse variasie neigings ‘n verhoging van 06h00 tot 18h00 getoon het. Die weeklikse neigings vir pH het van die van die temperatuur verskil. Die analises van kovariante het geen korrelasie (p < 0.05) tussen die fisiese-chemiese (temperature en pH) parameters en die mikrobe veranderlikes (TC en Ec) getoon nie. Dus is daar afgelei dat temperatuur en pH geen direkte impak op die totale kolivorm of E. coli tellings gehad nie. Die data van die studie het duidelik getoon dat water van beide die Plankenburg en Eerste Riviere nie geskik is vir gebruik vir besproeiing van vars produkte wat rou geëet gaan word nie. In beide gevalle het die fekale besmettingsvlakke die DWAF en WHO leistreep oorskry. Besproeiing met sulke water hou ‘n gesondheidsgevaar in as gevolg van die teenwoordigheid van potensiële patogene wat oorgedra kan word na vars produkte.
672

Detection of NheA from Bacillus spp. in food and soil isolates using real-time and rep-PCR / Detection of non-hemolytic enterotoxin A from Bacillus spp. in food and soil isolates using real-time and rep-polymerase chain reaction

Beer, Matthew R. 06 August 2011 (has links)
Bacillus cereus is traditionally thought to be the only member of its genus accepted as a pathogen in foods like grains, fruits, vegetables and milk due to the presence of the nonhemolytic (Nhe) operon. However, many other Bacillus spp. may also harbor the Nhe operon and be pathogenic. Real-time PCR targeted the nheA gene in 37 samples obtained from food, soil, and reference cultures by analyzing the standard deviations of melt peaks. Rep-PCR was used to compare the banding patterns of each sample against B. cereus ATCC14579 and three B. thuringiensis strains to “fingerprint” each isolate. Of the original 43 isolated tested, 37 were Gram-positive rods. The remaining six samples were Gram-positive cocci. Twenty-five of the 37 Gram-positive Bacillus spp. were nheA positive, while twelve were negative. Many of the nheA positive strains were species not previously known to contain Nhe, and were capable of causing gastroenteritis in consumers. / Department of Biology
673

Analysis of '1'3'7Cs contamination in soil using in-situ gamma spectrometry

MacDonald, Julian January 1999 (has links)
No description available.
674

A simulation-optimization model to study the control of seawater intrusion in coastal aquifers

Abd-Elhamid, Hany Farhat January 2010 (has links)
Groundwater contamination is a very serious problem as it leads to the depletion of water resources. Seawater intrusion is a special category of groundwater contamination that threatens the health and possibly lives of many people living in coastal areas. The focus of this work is to develop a numerical model to study seawater intrusion and its effects on groundwater quality and develop a control method to effectively control seawater intrusion. Two major approaches are used in this study: the first approach is the development of a finite element model to simulate seawater intrusion; the second is the development of a simulation-optimization model to study the control of seawater intrusion in coastal aquifers using different management scenarios. The simulation-optimization model is based on the integration of a genetic algorithm optimization technique with the transient density-dependent finite element model developed in this research. The finite element model considers the coupled flow of air and water and solute transport in saturated and unsaturated soils. The governing differential equations include two mass balance equations of water and air phases and the energy balance equation for heat transfer, together with a balance equation for miscible solute transport. The nonlinear governing differential equations are solved using the finite element method in the space domain and a finite difference scheme in the time domain. A two dimensional finite element model is developed to solve the governing equations and provide values of solute concentration, pore water pressure, pore air pressure and temperature at different points within the region at different times. The mathematical formulation and numerical implementation of the model are presented. The numerical model is validated by application to standard examples from literature followed by application to a number of case studies involving seawater intrusion problems. The results show good agreement with previous results reported in the literature. The model is then used to predict seawater intrusion for a number of real world case studies. The developed model is capable of predicting, with a good accuracy, the intrusion of seawater in coastal aquifers. In the second approach, a simulation-optimization model is developed to study the control of seawater intrusion using three management scenarios: abstraction of brackish water, recharge of fresh water and combination of abstraction and recharge. The objectives of these management scenarios include minimizing the total costs for construction and operation, minimizing salt concentrations in the aquifer and determining the optimal depths, locations and abstraction/recharge rates for the wells. Also, a new methodology is presented to control seawater intrusion in coastal aquifers. In the proposed methodology ADR (abstraction, desalination and recharge), seawater intrusion is controlled by abstracting brackish water, desalinating it using a small scale reverse osmosis plant and recharging to the aquifer. The simulation-optimization model is applied to a number of case studies. The efficiencies of three different scenarios are examined and compared. Results show that all the three scenarios could be effective in controlling seawater intrusion. However, ADR methodology can result in the lowest cost and salt concentration in aquifers and maximum movement of the transition zone towards the sea. The results also show that for the case studies considered in this work, the amount of abstracted and treated water is about three times the amount required for recharge; therefore the remaining treated water can be used directly for different proposes. The application of ADR methodology is shown to be more efficient and more practical, since it is a cost-effective method to control seawater intrusion in coastal aquifers. This technology can be used for sustainable development of water resources in coastal areas where it provides a new source of treated water. The developed method is regard as an effective tool to control seawater intrusion in coastal aquifers and can be applied in areas where there is a risk of seawater intrusion. Finally, the developed FE model is applied to study the effects of likely climate change and sea level rise on seawater intrusion in coastal aquifers. The results show that the developed model is capable of predicting the movement of the transition zone considering the effects of sea level rise and over-abstraction. The results also indicate that the change of water level in the sea side has a significant effect on the position of the transition zone especially if the effect of sea level rise is combined with the effect of increasing abstraction from the aquifer.
675

Transformations rédox et spéciation du Hg dans la neige et les eaux de surface de l'extrême arctique et de régions tempérées

Poulain, Alexandre January 2007 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
676

Razvoj modela uticaja čvrstih čestica na rad kontaktnih parova klip cilindar hidrauličkih komponenti / Development of a solid particle influence model on performance of pistoncylinder contacting pairs for hydraulic components

Karanović Velibor 14 May 2015 (has links)
<p style="text-align: justify;">U doktorskoj disertaciji je razmatran uticaj čvrstih čestica<br />mirkonskih razmera na kritične radne performanse kontaktnog para<br />klip-cilindar kao tipa kontakta koji je najzastupljeniji u hidrauličkim<br />komponentama. Prema konceptualnom modelu je izvedena<br />eksperimentalna instalacija na kojoj, za različite koncentracije<br />čvrstih čestica i određeni broj radnih ciklusa je ispitivan<br />intenzitet habanja, pad pritiska i veličina zapreminskih gubitaka<br />proticanja kroz zazor. Nad skupom prikupljenih eksperimentalnih<br />podataka je izvršena analiza i modelovanje funkcija koje opisuju<br />ponašanje posmatranih veličina.</p> / <p>This doctoral dissertation analyzes the influence of microscale solid particles<br />on the the critical operational performances of the most common type of<br />tribo-couples in power hydraulic components. According to the conceptual<br />model, experimental installation was made. For different solid particles<br />concentration levels and predefined number of working cycles, experimental<br />installation was used to examine intensity of wear, pressure drop and<br />volumetric efficiency &ndash; fluid loss trough the clearance. On the basis of<br />experimental data set was carried out analysis and modeling of functions that<br />describe the behavior of the observed parameters.</p>
677

Prozessdatenanalyse zur Inline-Verminderung von Störeinflüssen beim Ultraschallsiegeln / Process data analysis at ultrasonic sealing for inline prevention of failure

Thürling, Karsten 06 December 2016 (has links) (PDF)
Beim Siegeln von Verpackungen können nicht-qualitätsgerechte Siegelnähte dadurch entstehen, dass sich Teile des Packguts zwischen den zu fügenden Packmittelbahnen befinden. Im Gegensatz zum konventionellen Wärmekontaktsiegeln besteht beim Ultraschallsiegeln die Möglichkeit, für jeden einzelnen Siegelvorgang Prozessdaten zu erfassen. Aus dem Bereich des Ultraschallschweißens ist bekannt, dass sich anhand dieser Daten der Prozess überwachen und dessen Güte bewerten lässt. Die vorliegende Arbeit untersucht den Informationsgehalt dieser Prozessdaten hinsichtlich störungsbehafteter Siegelnähte und leistet damit einen Beitrag zur Verbesserung der Verpackungsqualität und damit im besten Fall auch zu weniger Lebensmittelverlusten. Es wird dazu zunächst eine Systematisierung von möglichen Störprinzipen beim Siegeln hinsichtlich ihrer physikalischen Wirkprinzipe vorgenommen. Darauf aufbauend konnte ein Versuchsstand und eine Methodik zur Untersuchung der Thematik entwickelt werden. Abschließend wurden ausgewählte Störprinzipe untersucht, wobei sich ein sehr starker Packstoff- und Einfluss der Prozessführung herausstellte. Es konnte ein prinzipieller Zusammenhang zwischen Auswirkung einer Störung auf die Nahtqualität und die Prozessdaten gezeigt werden, welcher sich jedoch auf Basis der erarbeiteten Ergebnisse nicht verallgemeinern lässt.
678

Validación de una escala para evaluar contaminación de alimentos en el hogar, estudio en la zona rural de Perú

Lozada Urbano, Michelle, Rivera, Roger, Miranda, Doris, Gallegos Vergara, Clara, Reyes Villegas, María Ysabel, Xirinachs Salazar, Yanira 02 December 2014 (has links)
Objetivos: validar una escala para evaluar la contaminación de alimentos en el hogar y, medir la validez y confiabilidad. Métodos: se encuestaron madres o cuidadoras con niños menores a 5 años, en San Juan de Lurigancho en Lima Perú. La escala fue previamente sometida a una calificación de jueces expertos. Se realizó el análisis de factores con componentes principales, la consistencia interna fue medida con Kuder–Richardson Formula 20 (KR-20) y la validez de la prueba con el coeficiente Kaiser-Meyer-Olkin (KMO) y el test de esfericidad de Barlet. Resultados: la muestra tuvo 194 cuidadoras. Se definieron tres componentes (prácticas de limpieza, prácticas de almacenaje y contaminación del niño) con un total de 10 ítems. El ítem Prácticas de limpieza tuvo un KR-20=0.722 prácticas de almacenaje y contaminación de alimentos 0.518 y 0.5 respectivamente. La validez de la prueba tuvo un KMO = 0.549 y un test de Barlet 591.678 , gl =136, (p<0.05). Conclusiones: esta escala puede contribuir a la planificación de intervenciones en el aspecto de contaminación en el hogar y por lo tanto reducir episodios de infecciones en los niños. / Objectives: To validate a scale to assess contamination of food at home and measure the validity and reliability. Methods: mothers or caregivers with children under 5 years were surveyed in San Juan de Lurigancho in Lima Peru. The scale was previously subject to a rating of expert judges. Factor analysis with principal components was performed; the internal consistency was measured with Kuder-Richardson Formula 20 (KR-20) and the validity of the test with the coefficient Kaiser-Meyer-Olkin (KMO) and the sphericity test Barlet. Results: The sample was 194 caregivers. Three components (Practices cleaning, storage practices and pollution of the child) with a total of 10 items were identified. The item Cleaning Practices had a KR-20 = 0.722 storage practices and food contamination 0.518 and 0.5 respectively. The validity of the test was KMO = 0.549 and 591,678. Barlet test, df = 136, (p <0.05). Conclusions: This scale can contribute to the planning of interventions in the aspect of pollution in the home and thus reduce episodes of infections in children.
679

Investigation of Ultratrace Metallic and Organic Contaminants in Semiconductor Processing Environments

Xu, Fei, 1971- 05 1900 (has links)
Detection of ultratrace levels of metallic ion impurities in hydrofluoric acid solutions and alkaline hydrogen peroxide solution was demonstrated using a silicon-based sensing electrode. The sensor's operation principle is based on direct measurements of the silicon open-circuit potential shift generated by the interaction between metallic ions and the silicon-based sensing surface. The new sensor can have practical applications in the on-line monitoring of microelectronic chemical processing. The detection of Ag+ content in KODAK waste water was carried out successfully by this novel sensor. Trace levels of organic impurities in the hydrofluoric acid solutions and in the cleanroom air were characterized by multiple internal reflection infrared spectroscopy (MIRIS) using an organics probe prepared directly from a regular silicon wafer.
680

Comparison of Remediation Methods in Different Hydrogeologic Settings Using Bioplume II

White, Sherry A. (Sherry Anne) 05 1900 (has links)
A contaminant fate and transport computer model, Bioplume II, which allows simulation of bioremediation in ground water systems, was used to compare the effects of 11 remediation scenarios on a benzene plume. The plume was created in three different hydrogeologic settings from the simulation of an underground gasoline storage tank leak.

Page generated in 0.0854 seconds