• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição ao controle tecnológico de concretos estruturais de cimento Portland em ambientes marítimos. / Contribution to field quality control of Portland cement structural concretes in maritime environments.

Cavalcanti Filho, Antonio Nereu 18 June 2010 (has links)
A durabilidade dos edifícios em concreto armado só pode ser alcançada se for atendido um conjunto de requisitos e critérios nas etapas de projeto, execução e manutenção, nas quais os materiais envolvidos precisam ser adequadamente especificados, produzidos e empregados, de acordo com as respectivas rotinas dessas etapas. Assim, o requisito genérico de proteção das armaduras de aço carbono, para a durabilidade de estruturas, é contemplado por vários critérios, desde a etapa de projeto. Esta dissertação trata dos critérios pertinentes à qualidade do concreto e visou contribuir para a evolução de procedimentos para o controle tecnológico de concretos estruturais de cimento Portland, em atmosferas marítimas e urbanas, em clima tropical, com vistas à proteção de armaduras de aço carbono. O programa experimental estudou três lotes diferentes de concretos estruturais, semelhantes quanto a especificações básicas de abatimento: 10 ± 2 cm, de fck 30 MPa e para ambiente classe III da NBR 6118 (2003). O objetivo foi caracterizar e analisar a influência de propriedades físicas do estado fresco sobre o estado endurecido de concretos, dentro da faixa de consistência citada, com ênfase nas propriedades relacionadas ao teor de ar das misturas e suas respectivas resistências à carbonatação e ao ingresso de íons cloreto. A amostragem, os ensaios no estado fresco e a moldagem dos corpos-de-prova foram realizados durante três concretagens conduzidas em duas obras de edifícios de múltiplos andares, na cidade de João Pessoa/PB. As composições e a produção dos lotes ficaram a cargo da central dosadora e fornecedora do concreto em cada obra. O lote inicial serviu para o treinamento da equipe, em campo e laboratório, com amostragem de seis caminhões. Os outros dois lotes, identificados como 1 e 2, foram caracterizados em condições bastante semelhantes, sempre pela mesma equipe, e representados pela amostragem de cinco e seis caminhões, respectivamente. As propriedades medidas no estado fresco foram: abatimento do tronco de cone pela ABNT NBR NM 67 (1998); teor de ar por método pressométrico da ABNT NBR 47 (2002); massa específica pela ABNT NBR 9833 (2008); relação água/materiais secos por analogia à ABNT NBR 9605 (1992); e compactabilidade dos concretos adensado e não adensado, por adaptação da BS EN 12350-4 (2008). Para o estudo das propriedades no estado endurecido, os corpos-de-prova eram cilíndricos, com 10 cm de diâmetro e 20 cm de altura, e foram maturados por dois métodos adaptados do Tipo A da ASTM C 684 (1999). Certas propriedades foram ainda caracterizadas para condições normais de cura da ABNT NBR 5738 (2003). As propriedades estudadas no estado endurecido foram: resistência à compressão pela ABNT NBR 5739 (2007); resistência à tração por compressão diametral pela ABNT NBR 7222 (1994); absorção de água por capilaridade pela ABNT NBR 9779 (1995); absorção de água total e índice de vazios pela ABNT NBR 9778 (2005); resistência à carbonatação em câmara com CO2 (5%; UR 65 + 10 %; 23 + 3 °C); e resistência à penetração de cloretos e CO2, por três ciclos de um dia de molhagem e 27 dias de secagem, entre sete e 91 dias. De modo complementar, foram moldados corpos-de-prova específicos de aço e concreto, para medidas de potencial de circuito aberto, com vistas à continuidade de pesquisas sobre envelhecimento acelerado. A maioria das propriedades foram medidas por duas repetições, constando os resultados individuais em apêndices. A análise inicial dos resultados dos três lotes foi descritiva e resumiu em tabelas o valor médio, desvio padrão, valor máximo, valor mínimo, a amplitude e o coeficiente de variação de cada lote. As propriedades de cada lote também foram comparadas por análise de variância e, ao final, foram correlacionadas de modo conjunto, independentemente do lote de origem. Nesse caso, foram destacadas as melhores correlações entre propriedades, independentemente dos materiais constituintes de cada concreto. Entre as propriedades do estado fresco, destacaram-se as seguintes: a) o abatimento do tronco de cone apresentou correlação forte e inversa (r² = -0,802, para lotes 1 e 2) com resistência à compressão após um dia de cura acelerada em temperatura moderada, em método similar ao Tipo A da ASTM C 684 (1999); b) o teor de ar pelo método pressométrico apresentou correlações de razoáveis a fortes com a resistência à compressão a 28 dias (r² = -0,698, para lotes 1 e 2), com a resistência à tração por compressão diametral por cura acelerada a sete dias (r² = -0,818, para lotes 1 e 2), com a profundidade de carbonatação em câmara de CO2 (r² = 0,699, para lotes 1 e 2) e com a profundidade de penetração de cloretos por três ciclos de imersão e secagem (r² = 0,625, para lotes 1 e 2); c) as medidas de compactabilidade do concreto adensado, ainda que realizadas em condições de campo, apresentaram várias correlações moderadas com outras propriedades do estado fresco e endurecido. No estado endurecido, destacaram-se as seguintes correlações: a) r² da ordem de -0,75 para a resistência à compressão a um dia dos concretos dos lotes 1 e 2, com cura acelerada de 0/24 horas em temperatura moderada, e a profundidade de carbonatação em câmara de CO2 (5%) e a de penetração de cloretos por três ciclos de imersão e secagem, ambas analisadas a 91 dias, tendo os corpos-de-prova recebido cura inicial acelerada de 24/48 h, em temperatura moderada, seguida de imersão normal por até sete dias; b) r² de -0,682 entre a resistência à tração por compressão diametral, com cura acelerada de 24/48h em temperatura moderada seguida de cura normal por até sete dias, e a profundidade de ingresso de íons cloreto, para os três lotes submetidos aos ciclos citados; c) valores de r² entre 0,521 e - 0,561 para as correlações entre a absorção de água por capilaridade, em corpos-de-prova submetidos à cura inicial acelerada em temperatura moderada por 24/48 h e em temperatura normal por até sete dias, e a resistência à carbonatação para os lotes submetidos aos ciclos citados. Assim, esta pesquisa conclui e propõe que, além do teor de ar no estado fresco, as resistências à compressão e à tração por compressão diametral entre um e sete dias, por cura acelerada do Tipo A da ASTM C 684 (1999) ou por duração adaptada da mesma, sejam propriedades que passem a ser avaliadas em concretos, com vistas a melhorar e controlar a sua resistência a agentes agressivos. Nesta pesquisa, a microestrutura nas primeiras idades do concreto mostrou ser mais determinante da rede de conexão de poros e do transporte de agentes agressivos do que a microestrutura em idades mais avançadas de hidratação; e trabalhos futuros devem confirmar esta interpretação. Espera-se que estes resultados possam estimular novas práticas de qualificação de concretos em estudos de dosagem ou no ato do recebimento de concretos pré-misturados, especialmente em ambientes mais agressivos às armaduras, com vistas à futura evolução de procedimentos da ABNT NBR 12655 (2006). / Durability of reinforced concrete buildings can only be achieved if a set of requirements and criteria is met in the design, execution and maintenance phases, in which the materials must be properly specified, manufactured and employed, according to the respective procedures of these phases. Therefore, the general requirement of protection of carbon steel reinforcements, for structural durability, is contemplated by several criteria as early as the design phase. This thesis addresses the relevant criteria concerning concrete quality and its objective was to contribute to the evolution of technological control procedures for Portland cement structural concretes, in urban and maritime atmospheres in tropical climate, aiming at the protection of carbon steel reinforcements. The experimental program studied three different batches of structural concrete that were similar in terms of slump test basic specifications: 10 ± 2 cm, fck = 30 MPa and class III of ABNT NBR 6118 (2003) environmental classification. The goal was to characterize and analyze the influence of physical properties of fresh concrete on hardened concrete, within the previously mentioned consistency range, with emphasis on those properties related to air content of the mixtures and their respective carbonation and chloride ion penetration resistances. Sampling, fresh concrete tests and specimen molding were conducted during three cast-in-place concretes in two construction sites of multi-storey buildings in the city of João Pessoa, state of Paraíba, in Brazil. The batch plant supplying the concrete for each construction site was responsible for batch composition and production. The initial batch was used to train the team, in the field and laboratory, with a sample of six trucks. The other two batches, identified as 1 and 2, were characterized under very similar conditions, always by the same team, and the samples consisted of five and six trucks, respectively. The properties measured in fresh concrete were: slump test according to Brazilian norm ABNT NBR NM 67 (1998); air content by the pressure method of ABNT NBR 47 (2002); bulk density according to ABNT NBR 9833 (2008); water/dry material ratio by analogy with ABNT NBR 9605 (1992); and compactability of compacted and non-compacted concretes, by adaptation of BS EN 12350-4 (2008). In order to study the properties of hardened concrete, the specimens were cylindrical, measuring 10 cm in diameter and 20 cm in height, and were matured by using two methods adapted from Type A of ASTM C 684 (1999). Some properties were also characterized for normal curing conditions according to ABNT NBR 5738 (2003). The properties studied in hardened concrete were: compressive strength according to ABNT NBR 5739 (2007); splitting tensile strength as per ABNT NBR 7222 (1994); capillary water absorption according to ABNT NBR 9779 (1995); water absorption by immersion and void ratio following ABNT NBR 9778 (2005); carbonation resistance in CO2 chamber (5%; 65 + 10 % RH; 23 + 3 °C); and chloride and CO2 penetration resistance, using three one-day wet and 27-day dry cycles, between seven and 91 days. As a complement, specific steel and concrete specimens were molded to measure open circuit potential, aiming at the continuity of researches on accelerated ageing. Most properties were measured twice and the individual results are presented in appendices. Preliminary analysis of results from the three batches was descriptive and summarized in tables the mean value, standard deviation, maximum value, minimum value, amplitude and coefficient of variation for each batch. The properties of each batch were also compared using analysis of variance and, at the end, were correlated as a whole, regardless of the batch of origin. In this case, the best correlations among properties were highlighted, regardless of the materials used in each concrete. Among the properties of fresh concrete, the following are noteworthy: a) the slump test presented strong and inverse correlation (r² = -0.802, for batches 1 and 2) with compressive strength after one day of accelerated curing at moderate temperature, using a method similar to Type A of ASTM C 684 (1999); b) air content in the pressure method presented reasonable to strong correlations with compressive strength at 28 days (r² = -0.698, for batches 1 and 2), with splitting tensile strength with accelerated curing at seven days (r² = - 0.818, for batches 1 and 2), with carbonation depth in CO2 chamber (r² = 0.699, for batches 1 and 2) and with chloride penetration depth after three immersion-drying cycles (r² = 0.625, for batches 1 and 2); c) compactability measurements of compacted concrete, despite being taken in field conditions, presented several moderate correlations with other properties of fresh and hardened concrete. In hardened concrete, the following correlations should be highlighted: a) r² was -0.75 for compressive strength at one day of the concretes from batches 1 and 2, with 0/24- hour accelerated curing at moderate temperature, and carbonation depth in CO2 chamber (5%) and chloride penetration depth after three immersion-drying cycles, both analyzed at 91 days, after the specimens underwent 24/48-hour initial accelerated curing at moderate temperature, followed by normal immersion for up to seven days; b) r² was -0.682 between splitting tensile strength, with 24/48-hour accelerated curing at moderate temperature followed by normal curing for up to seven days, and chloride ion penetration depth, for the three batches submitted to the aforementioned cycles; c) r² values between 0.521 and - 0.561 for the correlations between capillary water absorption, in specimens submitted to initial accelerated curing at moderate temperature for 24/48h and at normal temperature for up to seven days, and carbonation resistance for the batches submitted to the aforementioned cycles. Therefore, this research concludes and proposes that, besides air content in fresh concrete, compressive strength and splitting tensile strength between one and seven days, using accelerated curing of Type A of ASTM C 684 (1999) or for a duration adapted from that norm, are properties that should be evaluated in concrete, with the purpose of improving and controlling resistance to aggressive agents. In this research, the microstructure of the early ages of concrete proved to be more determinant of the pore structure connection and of the transport of aggressive agents than the microstructure at later ages of hydration; and future studies should confirm this interpretation. It is expected that these results will encourage new practices for the qualification of concrete in mixture proportion studies or when ready mixed concrete is received at construction sites, especially in environments that are more aggressive to reinforcements, with a view to developing future procedures of ABNT NBR 12655 (2006).
2

Contribuição ao controle tecnológico de concretos estruturais de cimento Portland em ambientes marítimos. / Contribution to field quality control of Portland cement structural concretes in maritime environments.

Antonio Nereu Cavalcanti Filho 18 June 2010 (has links)
A durabilidade dos edifícios em concreto armado só pode ser alcançada se for atendido um conjunto de requisitos e critérios nas etapas de projeto, execução e manutenção, nas quais os materiais envolvidos precisam ser adequadamente especificados, produzidos e empregados, de acordo com as respectivas rotinas dessas etapas. Assim, o requisito genérico de proteção das armaduras de aço carbono, para a durabilidade de estruturas, é contemplado por vários critérios, desde a etapa de projeto. Esta dissertação trata dos critérios pertinentes à qualidade do concreto e visou contribuir para a evolução de procedimentos para o controle tecnológico de concretos estruturais de cimento Portland, em atmosferas marítimas e urbanas, em clima tropical, com vistas à proteção de armaduras de aço carbono. O programa experimental estudou três lotes diferentes de concretos estruturais, semelhantes quanto a especificações básicas de abatimento: 10 ± 2 cm, de fck 30 MPa e para ambiente classe III da NBR 6118 (2003). O objetivo foi caracterizar e analisar a influência de propriedades físicas do estado fresco sobre o estado endurecido de concretos, dentro da faixa de consistência citada, com ênfase nas propriedades relacionadas ao teor de ar das misturas e suas respectivas resistências à carbonatação e ao ingresso de íons cloreto. A amostragem, os ensaios no estado fresco e a moldagem dos corpos-de-prova foram realizados durante três concretagens conduzidas em duas obras de edifícios de múltiplos andares, na cidade de João Pessoa/PB. As composições e a produção dos lotes ficaram a cargo da central dosadora e fornecedora do concreto em cada obra. O lote inicial serviu para o treinamento da equipe, em campo e laboratório, com amostragem de seis caminhões. Os outros dois lotes, identificados como 1 e 2, foram caracterizados em condições bastante semelhantes, sempre pela mesma equipe, e representados pela amostragem de cinco e seis caminhões, respectivamente. As propriedades medidas no estado fresco foram: abatimento do tronco de cone pela ABNT NBR NM 67 (1998); teor de ar por método pressométrico da ABNT NBR 47 (2002); massa específica pela ABNT NBR 9833 (2008); relação água/materiais secos por analogia à ABNT NBR 9605 (1992); e compactabilidade dos concretos adensado e não adensado, por adaptação da BS EN 12350-4 (2008). Para o estudo das propriedades no estado endurecido, os corpos-de-prova eram cilíndricos, com 10 cm de diâmetro e 20 cm de altura, e foram maturados por dois métodos adaptados do Tipo A da ASTM C 684 (1999). Certas propriedades foram ainda caracterizadas para condições normais de cura da ABNT NBR 5738 (2003). As propriedades estudadas no estado endurecido foram: resistência à compressão pela ABNT NBR 5739 (2007); resistência à tração por compressão diametral pela ABNT NBR 7222 (1994); absorção de água por capilaridade pela ABNT NBR 9779 (1995); absorção de água total e índice de vazios pela ABNT NBR 9778 (2005); resistência à carbonatação em câmara com CO2 (5%; UR 65 + 10 %; 23 + 3 °C); e resistência à penetração de cloretos e CO2, por três ciclos de um dia de molhagem e 27 dias de secagem, entre sete e 91 dias. De modo complementar, foram moldados corpos-de-prova específicos de aço e concreto, para medidas de potencial de circuito aberto, com vistas à continuidade de pesquisas sobre envelhecimento acelerado. A maioria das propriedades foram medidas por duas repetições, constando os resultados individuais em apêndices. A análise inicial dos resultados dos três lotes foi descritiva e resumiu em tabelas o valor médio, desvio padrão, valor máximo, valor mínimo, a amplitude e o coeficiente de variação de cada lote. As propriedades de cada lote também foram comparadas por análise de variância e, ao final, foram correlacionadas de modo conjunto, independentemente do lote de origem. Nesse caso, foram destacadas as melhores correlações entre propriedades, independentemente dos materiais constituintes de cada concreto. Entre as propriedades do estado fresco, destacaram-se as seguintes: a) o abatimento do tronco de cone apresentou correlação forte e inversa (r² = -0,802, para lotes 1 e 2) com resistência à compressão após um dia de cura acelerada em temperatura moderada, em método similar ao Tipo A da ASTM C 684 (1999); b) o teor de ar pelo método pressométrico apresentou correlações de razoáveis a fortes com a resistência à compressão a 28 dias (r² = -0,698, para lotes 1 e 2), com a resistência à tração por compressão diametral por cura acelerada a sete dias (r² = -0,818, para lotes 1 e 2), com a profundidade de carbonatação em câmara de CO2 (r² = 0,699, para lotes 1 e 2) e com a profundidade de penetração de cloretos por três ciclos de imersão e secagem (r² = 0,625, para lotes 1 e 2); c) as medidas de compactabilidade do concreto adensado, ainda que realizadas em condições de campo, apresentaram várias correlações moderadas com outras propriedades do estado fresco e endurecido. No estado endurecido, destacaram-se as seguintes correlações: a) r² da ordem de -0,75 para a resistência à compressão a um dia dos concretos dos lotes 1 e 2, com cura acelerada de 0/24 horas em temperatura moderada, e a profundidade de carbonatação em câmara de CO2 (5%) e a de penetração de cloretos por três ciclos de imersão e secagem, ambas analisadas a 91 dias, tendo os corpos-de-prova recebido cura inicial acelerada de 24/48 h, em temperatura moderada, seguida de imersão normal por até sete dias; b) r² de -0,682 entre a resistência à tração por compressão diametral, com cura acelerada de 24/48h em temperatura moderada seguida de cura normal por até sete dias, e a profundidade de ingresso de íons cloreto, para os três lotes submetidos aos ciclos citados; c) valores de r² entre 0,521 e - 0,561 para as correlações entre a absorção de água por capilaridade, em corpos-de-prova submetidos à cura inicial acelerada em temperatura moderada por 24/48 h e em temperatura normal por até sete dias, e a resistência à carbonatação para os lotes submetidos aos ciclos citados. Assim, esta pesquisa conclui e propõe que, além do teor de ar no estado fresco, as resistências à compressão e à tração por compressão diametral entre um e sete dias, por cura acelerada do Tipo A da ASTM C 684 (1999) ou por duração adaptada da mesma, sejam propriedades que passem a ser avaliadas em concretos, com vistas a melhorar e controlar a sua resistência a agentes agressivos. Nesta pesquisa, a microestrutura nas primeiras idades do concreto mostrou ser mais determinante da rede de conexão de poros e do transporte de agentes agressivos do que a microestrutura em idades mais avançadas de hidratação; e trabalhos futuros devem confirmar esta interpretação. Espera-se que estes resultados possam estimular novas práticas de qualificação de concretos em estudos de dosagem ou no ato do recebimento de concretos pré-misturados, especialmente em ambientes mais agressivos às armaduras, com vistas à futura evolução de procedimentos da ABNT NBR 12655 (2006). / Durability of reinforced concrete buildings can only be achieved if a set of requirements and criteria is met in the design, execution and maintenance phases, in which the materials must be properly specified, manufactured and employed, according to the respective procedures of these phases. Therefore, the general requirement of protection of carbon steel reinforcements, for structural durability, is contemplated by several criteria as early as the design phase. This thesis addresses the relevant criteria concerning concrete quality and its objective was to contribute to the evolution of technological control procedures for Portland cement structural concretes, in urban and maritime atmospheres in tropical climate, aiming at the protection of carbon steel reinforcements. The experimental program studied three different batches of structural concrete that were similar in terms of slump test basic specifications: 10 ± 2 cm, fck = 30 MPa and class III of ABNT NBR 6118 (2003) environmental classification. The goal was to characterize and analyze the influence of physical properties of fresh concrete on hardened concrete, within the previously mentioned consistency range, with emphasis on those properties related to air content of the mixtures and their respective carbonation and chloride ion penetration resistances. Sampling, fresh concrete tests and specimen molding were conducted during three cast-in-place concretes in two construction sites of multi-storey buildings in the city of João Pessoa, state of Paraíba, in Brazil. The batch plant supplying the concrete for each construction site was responsible for batch composition and production. The initial batch was used to train the team, in the field and laboratory, with a sample of six trucks. The other two batches, identified as 1 and 2, were characterized under very similar conditions, always by the same team, and the samples consisted of five and six trucks, respectively. The properties measured in fresh concrete were: slump test according to Brazilian norm ABNT NBR NM 67 (1998); air content by the pressure method of ABNT NBR 47 (2002); bulk density according to ABNT NBR 9833 (2008); water/dry material ratio by analogy with ABNT NBR 9605 (1992); and compactability of compacted and non-compacted concretes, by adaptation of BS EN 12350-4 (2008). In order to study the properties of hardened concrete, the specimens were cylindrical, measuring 10 cm in diameter and 20 cm in height, and were matured by using two methods adapted from Type A of ASTM C 684 (1999). Some properties were also characterized for normal curing conditions according to ABNT NBR 5738 (2003). The properties studied in hardened concrete were: compressive strength according to ABNT NBR 5739 (2007); splitting tensile strength as per ABNT NBR 7222 (1994); capillary water absorption according to ABNT NBR 9779 (1995); water absorption by immersion and void ratio following ABNT NBR 9778 (2005); carbonation resistance in CO2 chamber (5%; 65 + 10 % RH; 23 + 3 °C); and chloride and CO2 penetration resistance, using three one-day wet and 27-day dry cycles, between seven and 91 days. As a complement, specific steel and concrete specimens were molded to measure open circuit potential, aiming at the continuity of researches on accelerated ageing. Most properties were measured twice and the individual results are presented in appendices. Preliminary analysis of results from the three batches was descriptive and summarized in tables the mean value, standard deviation, maximum value, minimum value, amplitude and coefficient of variation for each batch. The properties of each batch were also compared using analysis of variance and, at the end, were correlated as a whole, regardless of the batch of origin. In this case, the best correlations among properties were highlighted, regardless of the materials used in each concrete. Among the properties of fresh concrete, the following are noteworthy: a) the slump test presented strong and inverse correlation (r² = -0.802, for batches 1 and 2) with compressive strength after one day of accelerated curing at moderate temperature, using a method similar to Type A of ASTM C 684 (1999); b) air content in the pressure method presented reasonable to strong correlations with compressive strength at 28 days (r² = -0.698, for batches 1 and 2), with splitting tensile strength with accelerated curing at seven days (r² = - 0.818, for batches 1 and 2), with carbonation depth in CO2 chamber (r² = 0.699, for batches 1 and 2) and with chloride penetration depth after three immersion-drying cycles (r² = 0.625, for batches 1 and 2); c) compactability measurements of compacted concrete, despite being taken in field conditions, presented several moderate correlations with other properties of fresh and hardened concrete. In hardened concrete, the following correlations should be highlighted: a) r² was -0.75 for compressive strength at one day of the concretes from batches 1 and 2, with 0/24- hour accelerated curing at moderate temperature, and carbonation depth in CO2 chamber (5%) and chloride penetration depth after three immersion-drying cycles, both analyzed at 91 days, after the specimens underwent 24/48-hour initial accelerated curing at moderate temperature, followed by normal immersion for up to seven days; b) r² was -0.682 between splitting tensile strength, with 24/48-hour accelerated curing at moderate temperature followed by normal curing for up to seven days, and chloride ion penetration depth, for the three batches submitted to the aforementioned cycles; c) r² values between 0.521 and - 0.561 for the correlations between capillary water absorption, in specimens submitted to initial accelerated curing at moderate temperature for 24/48h and at normal temperature for up to seven days, and carbonation resistance for the batches submitted to the aforementioned cycles. Therefore, this research concludes and proposes that, besides air content in fresh concrete, compressive strength and splitting tensile strength between one and seven days, using accelerated curing of Type A of ASTM C 684 (1999) or for a duration adapted from that norm, are properties that should be evaluated in concrete, with the purpose of improving and controlling resistance to aggressive agents. In this research, the microstructure of the early ages of concrete proved to be more determinant of the pore structure connection and of the transport of aggressive agents than the microstructure at later ages of hydration; and future studies should confirm this interpretation. It is expected that these results will encourage new practices for the qualification of concrete in mixture proportion studies or when ready mixed concrete is received at construction sites, especially in environments that are more aggressive to reinforcements, with a view to developing future procedures of ABNT NBR 12655 (2006).
3

Estudo sobre a variabilidade do módulo de deformação do concreto associada a fatores intrínsecos à produção do material. / Study of the variability of the concrete modulus of elasticity associated to intrinsic factors related to the material production.

Renata D\'Agostino De Marchi 25 October 2011 (has links)
Em função da especificação do módulo de elasticidade ou módulo de deformação do concreto ser cada vez mais frequente, se faz necessário o conhecimento da variabilidade desta propriedade, relacionada ao processo de produção, de modo a tornar mais confiável sua avaliação e que possibilite melhores condições no controle de produção para o atendimento aos requisitos associados a esta propriedade. Várias pesquisas têm comprovado que a variabilidade das propriedades mecânicas dos materiais de construção obedece a processos aleatórios. Portanto, os métodos de segurança no projeto estrutural devem estar fundamentados no conceito da teoria das probabilidades e não em métodos deterministas. Isso já acontece para a determinação da resistência à compressão, conforme estabelecido pela ABNT NBR 12655 (2006). A presente dissertação tem como objetivo principal estudar o controle experimental do módulo estático de deformação do concreto, mostrando a influência da variação dos materiais constituintes do concreto, dentro da realidade de uma Central de Concreto. Também objetiva apresentar uma discussão da aplicabilidade do conceito semiprobabilístico das normas nacionais de projeto, dosagem e controle tecnológico à propriedade módulo de deformação do concreto. A metodologia da pesquisa envolveu a escolha de uma central dosadora de concreto localizada na cidade de São Paulo, com a avaliação em dois concretos de resistências características (f ck ) de 25 e 30 MPa, que são comumente solicitados no mercado em que se insere. Para cada f ck foram realizados ensaios para determinação do módulo de deformação secante, E cs, três vezes por semana por um período de nove meses. Em função da precisão observada em pesquisa recente, foi utilizada a instrumentação clip gage para avaliação da propriedade módulo de deformação. Foram realizados ensaios sob o plano de carregamento secante, previsto na ABNT NBR 8522 (2008). Concluiu-se que, pelo fato do módulo de deformação do concreto ser influenciado pela resistência à compressão, que obedece a uma distribuição probabilística, não se pode atribuir à propriedade uma característica determinística, incorrendo no risco de não atendimento da propriedade. Recomendou-se o estabelecimento de tolerâncias para a especificação do módulo de deformação, uma vez que é uma variável com distribuição de probabilidade de rejeição. Sugeriu-se a discussão de mudança de enfoque no controle do módulo de deformação do concreto, com o controle por valor característico, tal qual ocorre para a resistência à compressão, atribuindo-se um estimador que atribua valores inferiores ao módulo de deformação, considerando-se uma rejeição aceitável. Também pode-se atribuir uma faixa de variação aceitável do valor em torno da média, uma vez que a responsabilidade estrutural do parâmetro módulo de deformação é menor do que o da resistência à compressão. / The modulus of elasticity requirements for concrete structures is becoming even more frequent. So, the knowledge of the variables involved in the experimental results became more important in order to make more reliable its assessment and enabling better conditions for specifications requirements attendance in relation to this property. Several studies have shown that the variability of mechanical properties of construction materials is subjected to random processes. Therefore, the security methods in the structural design must be based in the probability theory concept rather than deterministic methods. The randomness of the, compressive strength of concrete is already take in account in the quality control process according to the Brazilian Standard ABNT NBR 12655 (2006). The present work aims to study the experimental control of static modulus of elasticity of concrete, showing the influence of the constituent materials used in a Concrete Ready Mix Plant. It also intends to present a discussion on the applicability of the semi-probabilistic concept of national design standards in the mix design and production control of concrete in order to attend the elastic modulus requirements. The research methodology had two main steps: the first one, developed at a Concrete Ready Mix Plant located in São Paulo City, was based on the assessment of two characteristic compressive strength (f ck ) of 25 MPa and 30 MPa, which are commonly demanded in this market. For each strength class, tests were done to evaluate the variability of static modulus of elasticity of concrete, E cs, three times per week, during a period of nine months. On the second step, an analysis of elastic modules of concretes provided at six different sites, where the characteristic strength was 30 MPa, which was made using the same materials used in the first step. It has been used the clip gage instrumentation for measuring deformation to the assessment of static modulus of elasticity of concrete. It was used due to the precision that has been observed in recent research. The evaluation has been done according to the Brazilian Standard ABNT NBR 8522 (2008). It was possible to conclude that the modulus of elasticity of concrete is influenced by the compressive strength, so it follows a probabilistic distribution and cannot be associated to a deterministic model of quality control, due to the risk of non-compliance of the requirement. It was recommended the establishment of tolerances for the measured modulus of elasticity results, taking in account its random characteristic. The possibility of changing the focus on modulus of elasticity quality control was proposed, turning the deterministic criterion as occurs for the compressive strength, giving an estimator that assigns lower values to the modulus of elasticity, considering an acceptable rejection. It can be also based in a method that allows the acceptance of a concrete that lies within a predetermined tolerance around the average value, because the structural responsibility of modulus of elasticity is lower than the compressive strength.
4

Estudo sobre a variabilidade do módulo de deformação do concreto associada a fatores intrínsecos à produção do material. / Study of the variability of the concrete modulus of elasticity associated to intrinsic factors related to the material production.

De Marchi, Renata D\'Agostino 25 October 2011 (has links)
Em função da especificação do módulo de elasticidade ou módulo de deformação do concreto ser cada vez mais frequente, se faz necessário o conhecimento da variabilidade desta propriedade, relacionada ao processo de produção, de modo a tornar mais confiável sua avaliação e que possibilite melhores condições no controle de produção para o atendimento aos requisitos associados a esta propriedade. Várias pesquisas têm comprovado que a variabilidade das propriedades mecânicas dos materiais de construção obedece a processos aleatórios. Portanto, os métodos de segurança no projeto estrutural devem estar fundamentados no conceito da teoria das probabilidades e não em métodos deterministas. Isso já acontece para a determinação da resistência à compressão, conforme estabelecido pela ABNT NBR 12655 (2006). A presente dissertação tem como objetivo principal estudar o controle experimental do módulo estático de deformação do concreto, mostrando a influência da variação dos materiais constituintes do concreto, dentro da realidade de uma Central de Concreto. Também objetiva apresentar uma discussão da aplicabilidade do conceito semiprobabilístico das normas nacionais de projeto, dosagem e controle tecnológico à propriedade módulo de deformação do concreto. A metodologia da pesquisa envolveu a escolha de uma central dosadora de concreto localizada na cidade de São Paulo, com a avaliação em dois concretos de resistências características (f ck ) de 25 e 30 MPa, que são comumente solicitados no mercado em que se insere. Para cada f ck foram realizados ensaios para determinação do módulo de deformação secante, E cs, três vezes por semana por um período de nove meses. Em função da precisão observada em pesquisa recente, foi utilizada a instrumentação clip gage para avaliação da propriedade módulo de deformação. Foram realizados ensaios sob o plano de carregamento secante, previsto na ABNT NBR 8522 (2008). Concluiu-se que, pelo fato do módulo de deformação do concreto ser influenciado pela resistência à compressão, que obedece a uma distribuição probabilística, não se pode atribuir à propriedade uma característica determinística, incorrendo no risco de não atendimento da propriedade. Recomendou-se o estabelecimento de tolerâncias para a especificação do módulo de deformação, uma vez que é uma variável com distribuição de probabilidade de rejeição. Sugeriu-se a discussão de mudança de enfoque no controle do módulo de deformação do concreto, com o controle por valor característico, tal qual ocorre para a resistência à compressão, atribuindo-se um estimador que atribua valores inferiores ao módulo de deformação, considerando-se uma rejeição aceitável. Também pode-se atribuir uma faixa de variação aceitável do valor em torno da média, uma vez que a responsabilidade estrutural do parâmetro módulo de deformação é menor do que o da resistência à compressão. / The modulus of elasticity requirements for concrete structures is becoming even more frequent. So, the knowledge of the variables involved in the experimental results became more important in order to make more reliable its assessment and enabling better conditions for specifications requirements attendance in relation to this property. Several studies have shown that the variability of mechanical properties of construction materials is subjected to random processes. Therefore, the security methods in the structural design must be based in the probability theory concept rather than deterministic methods. The randomness of the, compressive strength of concrete is already take in account in the quality control process according to the Brazilian Standard ABNT NBR 12655 (2006). The present work aims to study the experimental control of static modulus of elasticity of concrete, showing the influence of the constituent materials used in a Concrete Ready Mix Plant. It also intends to present a discussion on the applicability of the semi-probabilistic concept of national design standards in the mix design and production control of concrete in order to attend the elastic modulus requirements. The research methodology had two main steps: the first one, developed at a Concrete Ready Mix Plant located in São Paulo City, was based on the assessment of two characteristic compressive strength (f ck ) of 25 MPa and 30 MPa, which are commonly demanded in this market. For each strength class, tests were done to evaluate the variability of static modulus of elasticity of concrete, E cs, three times per week, during a period of nine months. On the second step, an analysis of elastic modules of concretes provided at six different sites, where the characteristic strength was 30 MPa, which was made using the same materials used in the first step. It has been used the clip gage instrumentation for measuring deformation to the assessment of static modulus of elasticity of concrete. It was used due to the precision that has been observed in recent research. The evaluation has been done according to the Brazilian Standard ABNT NBR 8522 (2008). It was possible to conclude that the modulus of elasticity of concrete is influenced by the compressive strength, so it follows a probabilistic distribution and cannot be associated to a deterministic model of quality control, due to the risk of non-compliance of the requirement. It was recommended the establishment of tolerances for the measured modulus of elasticity results, taking in account its random characteristic. The possibility of changing the focus on modulus of elasticity quality control was proposed, turning the deterministic criterion as occurs for the compressive strength, giving an estimator that assigns lower values to the modulus of elasticity, considering an acceptable rejection. It can be also based in a method that allows the acceptance of a concrete that lies within a predetermined tolerance around the average value, because the structural responsibility of modulus of elasticity is lower than the compressive strength.
5

Estudo de métodos e medidas auxiliares para o controle da resistência à carbonatação de concretos estruturais de cimento Portland. / Study of auxiliary methods and measurements to control carbonation resistance of Portland cement structural concrete.

Cafange, Daniele Maria Pilla Junqueira 05 November 2010 (has links)
A durabilidade das estruturas de concreto armado deve ser alcançada, entre outros fatores, pela adequação do concreto frente ao meio ambiente para proteger as armaduras pelas características da camada de cobrimento. Assim, concretos precisam ser corretamente especificados no projeto estrutural e ter a sua qualidade controlada durante a produção e aplicação. Pela ABNT NBR 6118 (2007), os concretos passaram a ser especificados por classes de fck associadas a outras variáveis de dosagem e produção, como relação água/cimento máxima e consumo mínimo de cimento por metro cúbico. Mas, continuam invariavelmente controlados apenas por ensaios de abatimento no estado fresco e de resistência à compressão (fcj), para desforma ou verificação do fck (28 dias, nas obras comuns). Logo, a propriedade em uso para controlar indiretamente a resistência à carbonatação do concreto deveria ser o fcj, já que os concretos se diferenciam, de fato, é pelos materiais constituintes, método de dosagem e pela variabilidade de produção. Mas, na prática o controle da resistência à carbonatação dos concretos vem ocorrendo apenas pela especificação e aceitação do fck e uma das razões para isto pode ser a falta de métodos mais avançados para a predição de propriedades físicas mais complexas, como é a resistência à carbonatação. Assim, este trabalho visou contribuir para a evolução do controle tecnológico dessa propriedade em concretos estruturais, e o programa experimental teve por objetivos principais: testar o teor de ar no concreto fresco por quatro diferentes métodos, como variável auxiliar de controle; b) comparar três métodos acelerados de carbonatação; c) comparar área relativa e espessura de carbonatação, em seção diametral de corpos-de-prova cilíndricos de 10 cm x 20 cm, através de dois programas de análise de imagem e medida linear tradicional. Como concreto de estudo foi escolhido um da classe 30, pré-misturado e bombeável, de abatimento de 10 ± 2 cm, de relação água/cimento 0,60 e consumo de cimento igual a 300 kg/m³. Em uma dada central dosadora, foram então amostrados, aleatoriamente, as misturas de seis caminhões betoneira de 8 m³, produzidas em uma só data, de um dado lote de produção do citado concreto e para fornecimento a uma obra muito próxima. Cada mistura foi caracterizada no estado fresco, por oito diferentes propriedades e seguiu-se à moldagem de cilindros de 10 cm x 20 cm. A maior parte dos corpos-de-prova foi submetida à cura acelerada por imersão em tanque de água em temperatura amena (35 ± 5 °C), entre 1 e 3 dias, por adaptação do método A da ASTM C684, seguida de um resfriamento natural e cura a temperatura ambiente, no mesmo tanque, entre 3 e 7 dias. As propriedades no estado endurecido foram medidas a 8, 35, 63, 91 e 203 dias. As propriedades no estado fresco que melhor se relacionaram às medidas de carbonatação das seis misturas foram o teor de ar por método pressométrico e a medida de compactabilidade do concreto adensado, método adaptado da BS EN 12350-4 (2009). O teor de ar das misturas no estado fresco resultou com valor médio de 1,7% e mostrou correlações fortes e inversas com a resistência à compressão, resistência à tração por compressão diametral e com as medidas de profundidade de carbonatação. É recomendável prosseguir estudos sobre esse concreto, para elucidar as causas e os limites da correlação inversa, pois tanto podem ter resultado de efeitos do ar na interface pasta/agregados, quanto de sedimentação do concreto no estado plástico. A 203 dias, a espessura média de carbonatação pelos três métodos de envelhecimento acelerado resultou entre 4 e 5 mm, com coeficiente de variação entre 13% e 21% para oito dos nove grupos de doze corpos-de-prova (dois por mistura), no caso diferenciados pelo método de envelhecimento ou de medida da carbonatação. Por análise de variância para três fatores nessa idade, foram observadas equivalência entre as medidas de carbonatação, por dois dos métodos acelerados um de secagem contínua a 40°C em estufa ventilada e outro de um dia de exposição a CO2 (5% e U.R. 75%) alternado por 27 dias de secagem a 40°C em estufa ventilada, mas ambos não mostraram semelhança com o terceiro método, que foi de um dia de imersão em água alternada por 27 dias de secagem a 40°C em estufa ventilada. As medidas de carbonatação em corpos-de-prova submetidos a este terceiro método, envolvendo apenas imersão em água e secagem, resultaram com ótimo contraste com o indicador de fenolftaleína e foram as que mostraram maiores probabilidades de igualdade de médias, independente do método de medida. Espera-se que o prosseguimento de pesquisas com esses métodos possa trazer avanços no controle da resistência carbonatação de concretos, por valores médios ou característicos, e um melhor domínio tecnológico das variáveis de verificação da vida útil de projeto de armaduras e das estruturas em geral. / Durability of reinforced concrete structures should be obtained, among other factors, by adapting the concrete to the environment to protect the steel reinforcements depending on the characteristics of the cover layer. Therefore, concrete must be properly specified in the design structural and have its quality controlled during production and placing. After ABNT NBR 6118 (2007), concretes began to be specified according to fck classes in association with other mixture proportion and production variables, such as maximum water/cement ratio and minimum cement content per cubic meter. However, concretes are invariably controlled only through slump tests of fresh concrete and compressive strength tests (fcj) for stripping or assessment of fck (28 days, in common construction sites). As a result, the property in use to indirectly control concrete carbonation resistance should be fcj, since what actually differentiates the concretes are the constituent materials, the mix design and production variability. However, in practice, control of concrete carbonation resistance usually occurs through specification and acceptance of fck and one of the reasons for that may lie in the lack of more advanced methods to predict more complex physical properties, as in the case of carbonation resistance. Therefore, this study aimed to contribute to the evolution of technological control of this property in structural concrete and the experimental program had as its main goals: a) to test air content of fresh concrete by four different methods as auxiliary control variable; b) to compare three methods of accelerated carbonation; c) to compare relative area and carbonation thickness, in the diametral section of cylindrical specimens measuring 10 cm x 20 cm, through two image analysis softwares and traditional linear measurement. The concrete chosen for the purposes of this study was a class 30, ready mixed and pumped concrete, slump test of 10 ± 2 cm, water/cement ratio of 0.60 and cement content of 300 kg/m³. In a given batch plant, random samples were taken from the mixtures of six 8-m³ truck mixers that had been produced on the same date, from a given production batch of that concrete and for the supply of a nearby construction site. Each mixture was characterized in the fresh state, according to eight different properties, and then 10 cm x 20 cm cylinders were molded. Most specimens were submitted to accelerated curing by immersion in water tank at mild temperature (35 ± 5 °C), between 1 and 3 days, in an adaptation of method A of ASTM C684, followed by natural cooling and curing at room temperature, in the same tank, between 3 and 7 days. The properties in the hardened state were measured at 8, 35, 63, 91 and 203 days. The properties in the fresh state that best related to the carbonation measurements of the six samples were air content by the pressure method and compactability of compacted concrete, in a method adapted from BS EN 12350-4 (2009). Air content of the mixtures in the fresh state resulted in mean value of 1.7% and showed strong and inverse correlations with compressive strength, splitting tensile strength and with the measurements of carbonation depth. Further studies about this concrete are recommended to clarify the causes and limits of the inverse correlation, since they may result from effects of the air on the transition zone between paste and aggregates, or from concrete settlement in the fresh state. At 203 days, mean carbonation thickness in the three accelerated ageing methods resulted in between 4 and 5 mm, with coefficient of variation between 13% and 21% for eight out of nine groups of twelve specimens (two per mixture), which were differentiated according to the ageing method or the carbonation measurement. After an analysis of variance for three factors at this age, equivalences were observed in the carbonation measurements in two of the accelerated methods one of continuous drying at 40°C in ventilated oven and the other of one-day exposure to CO2 (5% and R.H. 75%) alternated with 27 days of drying at 40°C in ventilated oven, but neither showed similarity with the third method, which consisted in one-day water immersion alternated with 27 days of drying at 40°C in ventilated oven. Carbonation measurements in specimens submitted to the third method, involving only water immersion and drying, resulted in optimum contrast with the phenolphthalein indicator and showed higher probabilities of equality of means, regardless of the measurement method. It is expected that further research about these methods can bring advances in the control of concrete carbonation resistance, by mean or characteristic values, and better technological knowledge of the variables in verifying the design service life of steel reinforcement and structures in general.
6

Desempenho motor de indivíduos com paralisia cerebral em jogo virtual / Motor performance of individuals with cerebral palsy in a virtual game

Paula, Juliana Nobre de 14 September 2017 (has links)
A paralisia cerebral (PC) é uma desordem permanente do movimento, tônus muscular ou postura causada por dano ao cérebro imaturo ou em desenvolvimento. A pesquisa demonstrou que a tecnologia Realidade Virtual (RV) pode ser usada em reabilitação para apoiar a aquisição de habilidades motoras e a realização de tarefas funcionais. O objetivo deste estudo foi explorar melhorias no desempenho de indivíduos com PC com prática no uso de um jogo virtual em um telefone celular e comparar seu desempenho com o grupo controle. Materiais e Métodos: Vinte e cinco indivíduos com PC foram pareados por idade e sexo com vinte e cinco indivíduos com desenvolvimento tipico. Os participantes foram convidados a executar uma tarefa de labirinto virtual, o mais rápido possível, em um telefone celular. Todos os participantes realizaram 20 repetições na fase de aquisição com a mão dominante, após a fase de aquisição; houve 5 minutos de descanso, em que o indivíduo não teve contato com a tarefa. Então, os participantes foram convidados a realizar 5 repetições na fase de retenção de curto prazo, usando o mesmo labirinto de aquisição. Para a fase de transferência, houve 5 repetições, porém com um caminho do labirinto oposto à aquisição.Como resultado, o grupo PC melhorou seu desempenho na fase de aquisição, manteve o desempenho, que foi comprovadona fase de retenção; além disso, foram capazes de transferir o desempenho adquirido em um caminho de labirinto oposto. O grupo PC levou mais tempo para executar a tarefa de labirinto, comparado ao grupo controle em todas as fases do estudo. Conclusão: Indivíduos com Paralisia Cerebral realizaram um jogo de realidade virtual (tarefa de labirinto) utilizando um telefone celular e, apesar das diferenças do grupo de controle, esse tipo de dispositivo oferece novas possibilidades de uso em programas de reabilitação / Cerebral palsy (CP) is a permanent disorder of movement, muscle tone or posture that is caused by damage to the immature and developing brain. Research has shown that Virtual Reality (VR) technology can be used in rehabilitation to support the acquisition of motor skills and the achievement of functional tasks. The aim of this study was to explore for improvements in the performance of individuals with CP with practice in the use of a virtual game on a mobile phone and to compare their performance with that of the control group. Materials and Methods: Twenty-five individuals with CP were matched for age and sex with twenty-five, typically developing individuals. Participants were asked to complete a VR maze task as fast as possible on a mobile phone. All participants performed 20 repetitions in the acquisition phase with the dominant hand, after the acquisition phase; there was 5 minutes rest, in which the individual had no contact with the task. Then, participants were asked to complete 5 trials in the short-term retention phase using the same maze of acquisition. For the transfer phase, there were 5 trials with a path of the labyrinth opposed to the acquisition. As a result the CP group improved their performance in the acquisition phase and maintained the performance, which was shown by the retention test; in addition, they were able to transfer the performance acquired in an opposite maze path. The CP group had longer task-execution compared to the control group for all phases of the study. Conclusion: Individuals with cerebral palsy were able to learn a virtual reality game (maze task) using a mobile phone, and despite their differences from the control group, this kind of device offers new possibilities for use in rehabilitation programs
7

Estudo de métodos e medidas auxiliares para o controle da resistência à carbonatação de concretos estruturais de cimento Portland. / Study of auxiliary methods and measurements to control carbonation resistance of Portland cement structural concrete.

Daniele Maria Pilla Junqueira Cafange 05 November 2010 (has links)
A durabilidade das estruturas de concreto armado deve ser alcançada, entre outros fatores, pela adequação do concreto frente ao meio ambiente para proteger as armaduras pelas características da camada de cobrimento. Assim, concretos precisam ser corretamente especificados no projeto estrutural e ter a sua qualidade controlada durante a produção e aplicação. Pela ABNT NBR 6118 (2007), os concretos passaram a ser especificados por classes de fck associadas a outras variáveis de dosagem e produção, como relação água/cimento máxima e consumo mínimo de cimento por metro cúbico. Mas, continuam invariavelmente controlados apenas por ensaios de abatimento no estado fresco e de resistência à compressão (fcj), para desforma ou verificação do fck (28 dias, nas obras comuns). Logo, a propriedade em uso para controlar indiretamente a resistência à carbonatação do concreto deveria ser o fcj, já que os concretos se diferenciam, de fato, é pelos materiais constituintes, método de dosagem e pela variabilidade de produção. Mas, na prática o controle da resistência à carbonatação dos concretos vem ocorrendo apenas pela especificação e aceitação do fck e uma das razões para isto pode ser a falta de métodos mais avançados para a predição de propriedades físicas mais complexas, como é a resistência à carbonatação. Assim, este trabalho visou contribuir para a evolução do controle tecnológico dessa propriedade em concretos estruturais, e o programa experimental teve por objetivos principais: testar o teor de ar no concreto fresco por quatro diferentes métodos, como variável auxiliar de controle; b) comparar três métodos acelerados de carbonatação; c) comparar área relativa e espessura de carbonatação, em seção diametral de corpos-de-prova cilíndricos de 10 cm x 20 cm, através de dois programas de análise de imagem e medida linear tradicional. Como concreto de estudo foi escolhido um da classe 30, pré-misturado e bombeável, de abatimento de 10 ± 2 cm, de relação água/cimento 0,60 e consumo de cimento igual a 300 kg/m³. Em uma dada central dosadora, foram então amostrados, aleatoriamente, as misturas de seis caminhões betoneira de 8 m³, produzidas em uma só data, de um dado lote de produção do citado concreto e para fornecimento a uma obra muito próxima. Cada mistura foi caracterizada no estado fresco, por oito diferentes propriedades e seguiu-se à moldagem de cilindros de 10 cm x 20 cm. A maior parte dos corpos-de-prova foi submetida à cura acelerada por imersão em tanque de água em temperatura amena (35 ± 5 °C), entre 1 e 3 dias, por adaptação do método A da ASTM C684, seguida de um resfriamento natural e cura a temperatura ambiente, no mesmo tanque, entre 3 e 7 dias. As propriedades no estado endurecido foram medidas a 8, 35, 63, 91 e 203 dias. As propriedades no estado fresco que melhor se relacionaram às medidas de carbonatação das seis misturas foram o teor de ar por método pressométrico e a medida de compactabilidade do concreto adensado, método adaptado da BS EN 12350-4 (2009). O teor de ar das misturas no estado fresco resultou com valor médio de 1,7% e mostrou correlações fortes e inversas com a resistência à compressão, resistência à tração por compressão diametral e com as medidas de profundidade de carbonatação. É recomendável prosseguir estudos sobre esse concreto, para elucidar as causas e os limites da correlação inversa, pois tanto podem ter resultado de efeitos do ar na interface pasta/agregados, quanto de sedimentação do concreto no estado plástico. A 203 dias, a espessura média de carbonatação pelos três métodos de envelhecimento acelerado resultou entre 4 e 5 mm, com coeficiente de variação entre 13% e 21% para oito dos nove grupos de doze corpos-de-prova (dois por mistura), no caso diferenciados pelo método de envelhecimento ou de medida da carbonatação. Por análise de variância para três fatores nessa idade, foram observadas equivalência entre as medidas de carbonatação, por dois dos métodos acelerados um de secagem contínua a 40°C em estufa ventilada e outro de um dia de exposição a CO2 (5% e U.R. 75%) alternado por 27 dias de secagem a 40°C em estufa ventilada, mas ambos não mostraram semelhança com o terceiro método, que foi de um dia de imersão em água alternada por 27 dias de secagem a 40°C em estufa ventilada. As medidas de carbonatação em corpos-de-prova submetidos a este terceiro método, envolvendo apenas imersão em água e secagem, resultaram com ótimo contraste com o indicador de fenolftaleína e foram as que mostraram maiores probabilidades de igualdade de médias, independente do método de medida. Espera-se que o prosseguimento de pesquisas com esses métodos possa trazer avanços no controle da resistência carbonatação de concretos, por valores médios ou característicos, e um melhor domínio tecnológico das variáveis de verificação da vida útil de projeto de armaduras e das estruturas em geral. / Durability of reinforced concrete structures should be obtained, among other factors, by adapting the concrete to the environment to protect the steel reinforcements depending on the characteristics of the cover layer. Therefore, concrete must be properly specified in the design structural and have its quality controlled during production and placing. After ABNT NBR 6118 (2007), concretes began to be specified according to fck classes in association with other mixture proportion and production variables, such as maximum water/cement ratio and minimum cement content per cubic meter. However, concretes are invariably controlled only through slump tests of fresh concrete and compressive strength tests (fcj) for stripping or assessment of fck (28 days, in common construction sites). As a result, the property in use to indirectly control concrete carbonation resistance should be fcj, since what actually differentiates the concretes are the constituent materials, the mix design and production variability. However, in practice, control of concrete carbonation resistance usually occurs through specification and acceptance of fck and one of the reasons for that may lie in the lack of more advanced methods to predict more complex physical properties, as in the case of carbonation resistance. Therefore, this study aimed to contribute to the evolution of technological control of this property in structural concrete and the experimental program had as its main goals: a) to test air content of fresh concrete by four different methods as auxiliary control variable; b) to compare three methods of accelerated carbonation; c) to compare relative area and carbonation thickness, in the diametral section of cylindrical specimens measuring 10 cm x 20 cm, through two image analysis softwares and traditional linear measurement. The concrete chosen for the purposes of this study was a class 30, ready mixed and pumped concrete, slump test of 10 ± 2 cm, water/cement ratio of 0.60 and cement content of 300 kg/m³. In a given batch plant, random samples were taken from the mixtures of six 8-m³ truck mixers that had been produced on the same date, from a given production batch of that concrete and for the supply of a nearby construction site. Each mixture was characterized in the fresh state, according to eight different properties, and then 10 cm x 20 cm cylinders were molded. Most specimens were submitted to accelerated curing by immersion in water tank at mild temperature (35 ± 5 °C), between 1 and 3 days, in an adaptation of method A of ASTM C684, followed by natural cooling and curing at room temperature, in the same tank, between 3 and 7 days. The properties in the hardened state were measured at 8, 35, 63, 91 and 203 days. The properties in the fresh state that best related to the carbonation measurements of the six samples were air content by the pressure method and compactability of compacted concrete, in a method adapted from BS EN 12350-4 (2009). Air content of the mixtures in the fresh state resulted in mean value of 1.7% and showed strong and inverse correlations with compressive strength, splitting tensile strength and with the measurements of carbonation depth. Further studies about this concrete are recommended to clarify the causes and limits of the inverse correlation, since they may result from effects of the air on the transition zone between paste and aggregates, or from concrete settlement in the fresh state. At 203 days, mean carbonation thickness in the three accelerated ageing methods resulted in between 4 and 5 mm, with coefficient of variation between 13% and 21% for eight out of nine groups of twelve specimens (two per mixture), which were differentiated according to the ageing method or the carbonation measurement. After an analysis of variance for three factors at this age, equivalences were observed in the carbonation measurements in two of the accelerated methods one of continuous drying at 40°C in ventilated oven and the other of one-day exposure to CO2 (5% and R.H. 75%) alternated with 27 days of drying at 40°C in ventilated oven, but neither showed similarity with the third method, which consisted in one-day water immersion alternated with 27 days of drying at 40°C in ventilated oven. Carbonation measurements in specimens submitted to the third method, involving only water immersion and drying, resulted in optimum contrast with the phenolphthalein indicator and showed higher probabilities of equality of means, regardless of the measurement method. It is expected that further research about these methods can bring advances in the control of concrete carbonation resistance, by mean or characteristic values, and better technological knowledge of the variables in verifying the design service life of steel reinforcement and structures in general.
8

Desempenho motor de indivíduos com paralisia cerebral em jogo virtual / Motor performance of individuals with cerebral palsy in a virtual game

Juliana Nobre de Paula 14 September 2017 (has links)
A paralisia cerebral (PC) é uma desordem permanente do movimento, tônus muscular ou postura causada por dano ao cérebro imaturo ou em desenvolvimento. A pesquisa demonstrou que a tecnologia Realidade Virtual (RV) pode ser usada em reabilitação para apoiar a aquisição de habilidades motoras e a realização de tarefas funcionais. O objetivo deste estudo foi explorar melhorias no desempenho de indivíduos com PC com prática no uso de um jogo virtual em um telefone celular e comparar seu desempenho com o grupo controle. Materiais e Métodos: Vinte e cinco indivíduos com PC foram pareados por idade e sexo com vinte e cinco indivíduos com desenvolvimento tipico. Os participantes foram convidados a executar uma tarefa de labirinto virtual, o mais rápido possível, em um telefone celular. Todos os participantes realizaram 20 repetições na fase de aquisição com a mão dominante, após a fase de aquisição; houve 5 minutos de descanso, em que o indivíduo não teve contato com a tarefa. Então, os participantes foram convidados a realizar 5 repetições na fase de retenção de curto prazo, usando o mesmo labirinto de aquisição. Para a fase de transferência, houve 5 repetições, porém com um caminho do labirinto oposto à aquisição.Como resultado, o grupo PC melhorou seu desempenho na fase de aquisição, manteve o desempenho, que foi comprovadona fase de retenção; além disso, foram capazes de transferir o desempenho adquirido em um caminho de labirinto oposto. O grupo PC levou mais tempo para executar a tarefa de labirinto, comparado ao grupo controle em todas as fases do estudo. Conclusão: Indivíduos com Paralisia Cerebral realizaram um jogo de realidade virtual (tarefa de labirinto) utilizando um telefone celular e, apesar das diferenças do grupo de controle, esse tipo de dispositivo oferece novas possibilidades de uso em programas de reabilitação / Cerebral palsy (CP) is a permanent disorder of movement, muscle tone or posture that is caused by damage to the immature and developing brain. Research has shown that Virtual Reality (VR) technology can be used in rehabilitation to support the acquisition of motor skills and the achievement of functional tasks. The aim of this study was to explore for improvements in the performance of individuals with CP with practice in the use of a virtual game on a mobile phone and to compare their performance with that of the control group. Materials and Methods: Twenty-five individuals with CP were matched for age and sex with twenty-five, typically developing individuals. Participants were asked to complete a VR maze task as fast as possible on a mobile phone. All participants performed 20 repetitions in the acquisition phase with the dominant hand, after the acquisition phase; there was 5 minutes rest, in which the individual had no contact with the task. Then, participants were asked to complete 5 trials in the short-term retention phase using the same maze of acquisition. For the transfer phase, there were 5 trials with a path of the labyrinth opposed to the acquisition. As a result the CP group improved their performance in the acquisition phase and maintained the performance, which was shown by the retention test; in addition, they were able to transfer the performance acquired in an opposite maze path. The CP group had longer task-execution compared to the control group for all phases of the study. Conclusion: Individuals with cerebral palsy were able to learn a virtual reality game (maze task) using a mobile phone, and despite their differences from the control group, this kind of device offers new possibilities for use in rehabilitation programs

Page generated in 0.4428 seconds