• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 12
  • 12
  • 12
  • 12
  • 11
  • 1
  • 1
  • Tagged with
  • 28
  • 28
  • 19
  • 12
  • 12
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise histopatológica do comportamento pulpar, pós cimentação de coroas totais metálicas com cimentos de ionômero vítreo e fosfato de zinco /

Nogueira Junior, Lafayette. January 1997 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Cícero Eleutério da Silva Filho / Banca: Yasmin Rodarte Carvalho / Resumo: Com o objetivo de avaliar histopatologicamente o comportamento pulpar pós-cimentação de coroas totais metálicas (CTM) com um cimento de fosfato de zinco (Lee Smith, Vigodent) e dois cimentos de ionômero vítreo (Ketac-Cem, ESPE; Vidrion C, SSWhite), foram realizados 27 preparos coronários em pré-molares íntegros indicados para exodontia com a finalidade de tratamento ortodôntico. As exodontias foram realizadas após três, dez e trinta dias da cimentação. Para o exame histopatólogico a polpa foi removida do dente e corada pelo hematoxilina e eosina. Os resultados mostraram que aos três dias, que seis das nove polpas apresentavam alguma reação inflamatória, o comportamento entre os cimentos foi diferente quanto ao grau de resposta inflamatória, a reação inflamatória persistiu após trinta dias com o Lee Smith (CFZ) e Ketac-Cem (CIV), o grupo do Vidrion C (CIV) foi o qual apresentou melhor biocompatibilidade. A metodologia usada permitiu uma avaliação das condições pulpares em um período mais curto que o processo convencional de descalcificação, entretanto não possibilitou a observação da interação polpa/dentina / Abstract: The purpose of this study was to conduct an histological evaluation of pulp rections of teeth after cementation of complete metal crowns with one of the following luting agents: zinc phosphate cement (ZPC) (Lee Smith, Vigodent) and two glass ionomer cements (Ketac Cem, ESPE, Vidrion C, SSWhite). Twenty seven sound bicuspids scheduled for extraction by orthodontic treatment were prepared for complete crowns, casts were made and luted with one of the above cements. Three, ten and thirty days after cementation the teeth were removed, split in two halves and the pulps detached from one of the halves, stained with H.E. and pulpal reactions assessed by optical microscopy. Results showed dissimilar inflammatory responses that were associated to the different cementing agents. For specimens of the ZPC and Ketac-Cem groups the inflammatory reaction subsided for 30 days. For the Vidrion C group only 2 out of 9 specimens showed pulpal inflammatory reactions. Therefore, regarding biocompatibility, best results were seen with the specimens ofthe Vidríon C group. The method allowed a quick assessment of pulp conditions when compared to the traditional decalcifiyng process. However, observations of dentin-pulp relationships could not be noticed / Mestre
12

Fratura precoce da porcelana em restaurações com infra-estrutura de zircônia : influência de gradientes térmicos no desenvolvimento e magnitude de tensões residuais e transitórias /

Benetti, Paula. January 2012 (has links)
Orientador: Alvaro Della Bona / Coorientador: Tarcísio José Arruda Junior / Coorientador: John Robert Kelly / Banca: Alexandre Luiz Souto Borges / Banca : Rubens Nisie Tango / Banca : Liliana Gressler May / Banca : Mario Alexandre Coelho Sinhoreti / Resumo: Esse estudo avaliou o desenvolvimento de tensões dentro da porcelana de restaurações metalo-cerâmicas (MC) e de zircônia-porcelana (ZC) como resultado de diferentes taxas de resfriamento a partir de temperaturas acima da transição vítrea (Tg). Restaurações unitárias (coroas) foram fabricadas com 1 ou 2 mm de espessura de porcelana. Termopares foram posicionados nas superfícies de cimentação (T1) e oclusal (T4) e inseridos na interface (T2) e dentro da porcelana (T3). Para o resfriamento rápido, o forno foi aberto imediatamente após o tempo de sinterização e desligado. O resfriamento lento foi obtido pela abertura do forno quando a 50°C abaixo da Tg. Modelos axi-simétricos foram construídos para simulação de tensões térmicas tempo-dependentes usando análise de elementos finitos (AEF). Equações de temperatura em função do tempo obtidas por termopares foram inseridas no modelo como condições das margens. A mudança do coeficiente de expansão térmica, densidade, módulo de cisalhamento, capacidade térmica e da Tg de acordo com a taxa de resfriamento foi considerada para simulação do comportamento da porcelana em temperaturas acima da Tg (visco-elástico). O comportamento dos materiais de infra-estrutura e da porcelana abaixo da Tg foi considerado elástico. A taxa de resfriamento na faixa de temperatura próxima a Tg foi 20°C/min e 900°C/min para resfriamento lento e rápido. Durante o resfriamento lento, os diferentes termopares mostraram temperaturas similares em ambas as coroas. Gradientes de temperatura foram observados no resfriamento rápido da coroa ZC (T1-T4 = 100°C) e, em menor magnitude, para a MC (T1-T4 = 30°C). Os resultados de AEF mostraram diferenças de tensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the development of transient and residual stresses within the porcelain of veneered restorations (zirconia- and metal-based) as a result of different cooling rates from temperatures above the glass transition temperature (Tg). All-ceramic (porcelain on zirconia-based ceramic) and porcelain-fused-to-metal (PFM) molar crowns were fabricated with 1 mm or 2 mm porcelain thickness. Thermocouples were attached to intaglio (T1) and occlusal (T4) surfaces and embedded within the ceramics interface (T2) and inside the porcelain (T3) to acquire temperature readings by time. For fast cooling, the furnace was opened immediately after the holding time and switched off afterward. Slow cooling was determined by opening the furnace when it reached 50 °C bellow the Tg. Axially-symmetric crown-like models were constructed to perform a simulation of time-dependent thermal stresses using finite element analyses (FEA). Time-dependent temperature equations from thermocouples were set as boundary conditions for surfaces of the model. Coefficient of thermal expansion, density, shear modulus, heat capacity and Tg dependency on cooling rate were considered for the porcelain simulation (visco-elastic above Tg). Porcelain below the Tg and the framework materials were considered to behave elastically. The cooling rates at Tg range were 20 °C/min and 900 °C/min for slow and fast cooling. During slow cooling, different thermocouples showed similar temperatures for both zirconia and metal crowns. Remarkable temperature gradients were observed for the fast cooled all-ceramic crown (T1-T4 = 100 °C) and, of lower magnitude, for PFM (T1-T4 = 30 °C). FEA results showed differences... (Complete abstract click electronic access below) / Doutor
13

Distribuição de tensões e probabilidade de falha de coroas totais em zircônia tradicional, graduada e bioinspirada /

Ramos, Gabriela Freitas. January 2018 (has links)
Orientador: Renata Marques de Melo Marinho / Banca: Lafayette Nogueira Junior / Banca : Tarcisio José de Arruda Paes Junior / Banca: Laís Regiane da Silva Concilio / Banca: Marina da Rosa Kaizer / Resumo: O objetivo foi avaliar a probabilidade de falha de coroas de zircônia-porcelana com e sem infiltração de sílica (gradação) da zircônia, em disposição tradicional, graduada e bioinspirada, através da análise de Weibull e de elementos finitos pelo critério de Tensão Máxima Principal. Foram utilizados cem preparos anatômicos de primeiro molar superior (26) confeccionados em resina epóxi- Nema G10, que foram divididos em quatro grupos: Tradicional: infraestrutura em zircônia (Zircônia Convencional-Incoris ZI, Sirona, Brasil) e cobertura de porcelana (Cerâmica Feldspática-Cerec Blocs); Graduada: infraestrutura em zircônia infiltrada por sílica e cobertura de porcelana; Bioinspirada: infraestrutura em porcelana e cobertura com zircônia (Zircônia translúcida-Incoris TZI, Sirona, Brasil); e Bioinspirada Graduada: infraestrutura em porcelana e cobertura com zircônia infiltrada por sílica. A porção mais externa de todas as coroas foi revestida com uma camada glaze. A carga para fadiga deslizante foi de 100 N. Então os espécimes foram ciclados mecanicamente em um simulador de ciclos mastigatórios no qual uma ponta aplicadora fez 2.106 ciclos a uma frequência de 4 Hz. A cada 500.000 ciclos as coroas foram avaliadas quanto à presença de falhas (trincas, lascamentos ou descolamento entre porcelana e zircônia, fraturas catastróficas), em estereomicroscópio. Os tipos de falhas predominantes para as coroas Tradicional e Graduada foram delaminação e trincas, respectivamente. Os parâmetros de W... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective was to evaluate the failure probability of zirconia-porcelain crowns with and without silica infiltration (graded material) of the zirconia, using traditional, graded and bio-inspired design, through Weibull and finite element analysis by maximum principal stress. One hundred anatomical preparations of first upper molar were made of epoxy resin Nema G10 and divided into four groups: Traditionalzirconia (Conventional zirconia -Incoris ZI, Sirona, Brazil) and porcelain cover (Feldsphatic ceramic-Cerec Blocks); Graded- infrastructure in zirconia silica infiltrated and porcelain cover; Bioinspired- porcelain infrastructure and zirconia cover (Trasnlucent zirconia-Incoris TZI, Sirona, Brazil); and Graded Bioinspired- porcelain infrastructure and zirconia infiltrated by silica cover. The outermost portion of all crowns was coated with a glaze layer. The load for sliding fatigue was 100 N. Then the specimens were mechanically cycled in a masticatory cycle simulator for 2 x 106 cycles at 4 Hz of frequency. Every 500k cycles the crowns were evaluated in stereomicroscope for failures presence (cracks, chipping or detachment between porcelain and zirconia, or catastrophic fractures). The predominant failure types for the Traditional and Graded crowns were delamination and cracking, respectively. The Weibull parameters (beta and eta) with 95% bilateral confidence interval were respectively: Traditional - 1.29 and 0.23 E + 07 cycles; Graded - 1.95 and 0.23 E + 07 cycles; Bioinspired - 1,00 and 1,67 E + 07 cycles and Graded Bioinspired - 1,00 1,67 E + 07 cycles. The Traditional and Graded crowns presented greater susceptibility to failure due to fatigue and the Bioinspired and Graded Bioinspired crowns showed no susceptibility to fatigue. Also, through the finite elements analysis, it was verified that the Bioinspired and Graded Bioinspired crowns presented the ..((Resumo completo, clicar acesso eletrônico) / Doutor
14

Análise da interface adesiva entre cimentos resinosos e diferentes terços da dentina intrarradicular /

Suzuki, Thaís Yumi Umeda. January 2011 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Ana Flávia Sanches Borges / Banca: Wirley Gonçalves Assunção / Resumo: O propósito deste estudo foi avaliar as técnicas de cimentação adesiva de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através da resistência de união e avaliação de propriedades mecânicas da interface adesiva. Quarenta dentes humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em cinco grupos experimentais (n=8), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo 1: adesivo fotoativado Single Bond 2 + cimento resinoso RelyX ARC; Grupo 2: adesivo dual Excite DSC + RelyX ARC; Grupo 3: adesivo autocondicionante Adper SE Plus + RelyX ARC; Grupo 4: cimento resinoso autoadesivo RelyX Unicem; Grupo 5: cimento resinoso autoadesivo Set. As propriedades mecânicas de dureza e módulo de elasticidade foram mensuradas nas estruturas da interface adesiva em ultramicrodurômetro digital DUH-211. A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal nos diferentes terços da dentina intrarradicular (cervical, médio e apical). Os dados de resistência de união e propriedades mecânicas foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA e teste de Fisher ( = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza Martens e módulo de elasticidade dos materiais adesivos e do substrato dentinário são influenciados pela interação dos materiais resinosos utilizados, bem como pela profundidade intrarradicular. O mesmo fenômeno foi observado no teste de resistência de união. Para os materiais resinosos, houve uma tendência de o terço apical apresentar os menores valores das propriedades analisadas, o que poderia conduzir à realização de preparos intrarradiculares mais conservativos / Abstract: The purpose of this study was to evaluate techniques for adhesive cementation of glass fiber posts in different thirds of intra-root dentin, through the bond strength and evaluation of mechanical properties of the adhesive interface components. Forty extracted single-rooted human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups (n=8), according to the technique adopted for adhesive cementation of glass fiber posts: Group 1: Single Bond 2 light-cured adhesive + RelyX ARC resin cement; Group 2: Excite DSC dual adhesive + RelyX ARC; Group 3: Adper SE Plus self-etch adhesive + RelyX ARC; Group 4: RelyX Unicem self-adhesive resin cement; Group 5: Set selfadhesive resin cement. The mechanical properties of Martens hardness and elastic modulus were measured in the structures of the adhesive interface in a DUH-211 digital ultramicro hardness tester (Shimadzu). Push-out bond strength was measured in a universal testing machine (Emic DL 3000) in different areas of intra-root dentin (cervical, middle and apical). The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA and Fisher's test ( =0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of the adhesive materials and dentin substrate can be influenced by the interaction of the materials, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bonding strength test. There was a tendency of the apical region show the least values of mechanical properties, which could stimulate the use of more conservative intraradicular preparation / Mestre
15

Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas "in vivo" /

Pavanelli, Carlos Augusto. January 1997 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eulália Maria Martins Silva / Banca: Marcos Yasunóri Maekawa / Resumo: A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que... / Abstract: This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement / Mestre
16

Estudo "in vitro" do comportamento de facetas confeccionadas com artglass e targis quando submetidas à inserção e remoção de grampos circunferenciais em cromo-cobalto /

Marchini, Leonardo. January 2000 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Cícero Eleutério da Silva Filho / Banca: Maria Amélia Maximo de Araujo / Resumo: Tendo por objetivo investigar in vitro o comportamento das facetas estéticas confeccionadas com as resinas laboratoriais Artglass e Targis, colocadas em coroas veneer, quando submetidas à inserção e remoção de grampos circunferenciais de cromo-cobalto, foram confeccionadas 24 coroas veneer, sendo doze com faceta estética de Artglass (Heraeus Kulzer) e doze de Targis (Ivoclar Vivadent) e os respectivos grampos de cromo-cobalto. As coroas foram então submetidas a cinco mil ciclos de inserção e remoção dos grampos, em dispositivo destinado para tal. Mediante a aferição da força necessária para a remoção dos grampos das coroas durante os ensaios, da variação da massa dos grampos e coroas e da verificação macroscópica das facetas, foi possível concluir que as facetas estéticas não apresentam variação significativa na força necessária para a remoção dos grampos; apresentam pequena abrasão, observável por inspeção visual e apresentam pequena e variável perda de massa, menor para aquelas confeccionada em Artglass (0,002g em média) e maior para aquelas confeccionadas em Targis (0,006g em média) / Abstract: Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g) / Mestre
17

Avaliação "in vitro " da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos /

Bottino, Marco Antonio. January 1998 (has links)
Resumo: Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study assessed the quality of cervical adaptation in full metal crowns, with a variation in: a) the type of cervical preparation- beveled shoulder, 135-degree preparation, 90-degree shoulder, chamfer and knife edge; b) internal surfaces of the crowns with or without relief; c) the types of luting agents and their commercial brands- Harvard zinc phosphate, Ketac-Cem glass ionomer, Durelon zinc polycarboxylate and Panavia Ex resinous. Initially, machined stainless steel models were made according to each experimental margin design. Stainless steel metal caps were prepared with or without a 30-micrometer spacing of their internal surfaces, kept away 0.5 mm of the cervical end limit; they were precisely fitted, making a set with exact adaptation and seating. The caps were cemented on the specimens by means of different luting agents , handled according to the manufacturer's instructions. Methods were developed to reuse the specimens. Precise measures were obtained by preventing caps from moving during measurements. The conclusions were: a) the best mean of cervical adaptation, similar to each other , was obtained in standard models with preparations : knife edge, 1350 shoulder and chamfer; b) the worst mean of cervical adaptation, similar between them , was obtained in standard models with: straight shoulder and beveled shoulder; c) there was a significant improvement in adaptation when the metal caps were cemented with relief in their internal surface; d) cements presented decreasing cervical adaption, in the following order: Ketac-Cem, Harvard, Durelon and Panavia Ex; and, e) the methodology used allowed work with positive values of cervical adaptation.
18

Avaliação da confiabilidade e modo de falha de coroas cerâmicas em função do módulo de elasticidade dos endentadores / Effect of indenter material on reliability of all-ceramic crowns

Fabio Cesar Lorenzoni 03 May 2013 (has links)
A incompatibilidade entre o módulo de elasticidade (E) do endentador e dos materiais cerâmicos durante os testes de fadiga tem gerado controvérsias. Foram testadas as hipóteses que coroas totalmente cerâmicas apresentarão confiabilidade à fadiga acelerada progressiva do tipo step-stress (hipótese 1) e modos de falha (hipótese 2) similares, quando dois endentadores, um à base de carboneto de tungstênio (WC, E = 600 GPa) e outro de cerâmica esteatite [SB, E = 90 GPa] forem utilizados para transferir a carga. Para avaliar o efeito dos endentadores, um preparo para coroa total em um molar inferior foi realizado. A partir deste modelo mestre, 42 coroas à base de Y-TZP e 42 réplicas em resina composta foram produzidas. As réplicas em resina foram envelhecidas por 30 dias. Todas as coroas foram cimentadas sobre estas réplicas com cimento autoadesivo (Rely X Unicem - 3M/ESPE, St. Paul, EUA) e divididas em dois grupos de acordo com o endentador (WC ou SB). As coroas foram submetidas tanto ao teste de resistência à fratura (n = 3 por grupo), empregado para determinar os perfis de carga (leve, moderado e agressivo) quanto à fadiga (n = 18 por grupo), utilizando um endentador novo para cada coroa. Impressões de todas as coroas e endentadores submetidos ao perfil leve foram obtidas, em pontos específicos do perfil (0, 40k, e, 80k 120k, 160k), vazadas com resina epóxi e avaliadas sob MEV, com a finalidade de inspecionar a morfologia e medir a área endentada. O Use level Probability mostrou sobreposição entre os intervalos de confiança, indicando que não houve diferença significante entre os grupos, independente do critério de falha. O módulo de Weibull Beta (&#x3B2;) calculado para IA (análise inicial) foi de 1,99 e 1,67 para SB e WC, respectivamente, apontando que a fadiga acelerou o fracasso em ambos os grupos. Este não foi o caso para os valores de &#x3B2; para a análise de FA (análise final) (SB = 1,1 e WC = 0,72), revelando que a carga pode ter influenciado sozinha o mecanismo de falha. Ambos os endentadores produziram padrões semelhantes de desgaste/danos nas coroas. A análise fractográfica revelou modos de falhas concorrentes, mas as trincas tipo cone parciais foram as mais dominantes em ambos os grupos. As medições das áreas endentadas mostraram diferença estatística entre os grupos (SB vs. WC) (p <0,05). No geral, o endentador WC exibiu área maior do que a produzida pelo SB. O endentador mais compatível (SB) com a superfície cerâmica produziu confiabilidade e modos de falhas semelhantes ao ser comparada com o WC; assim, as hipóteses 1 e 2 foram aceitas. / Concerns about elastic modulus (E) mismatch between indenter and ceramic materials during fatigue testing have generated controversy. We hypothesized that all-ceramic crowns will exhibit similar step-stress sliding contact fatigue reliability (hypothesis 1) and failure characteristics (hypothesis 2) when using high stiffness tungsten carbide (WC, E = 600 GPa) vs enamel like steatite (SB, E = 90 GPa) indenters. To evaluate the effect of indenters, a preparation for a full crown was made on a first lower molar. From this master die 42 Y-TZPveneered all-ceramic crowns and 42 tooth-resin réplicas were made. Crowns were cemented onto the aged (30 days) tooth-resin réplicas with self-adhesive resin-based cement (Rely X UniCem - 3M/ESPE, St. Paul, USA). After, crowns were divided into two groups according to indenter (WC or SB). Specimens were subject to single-load to fracture (n = 3 per indenter type) to determine the step-stress profiles (mild, moderate, and aggressive) and to mouthmotion step-stress fatigue-tested (n = 18 per indenter type). Two failure modes were determined (inital analysis [IA] and final analysis [FA]). For each crown, a new indenter was used and labelled accordingly for surface damage evaluation. Impressions from all crowns subjected to mild profile were taken following a pre-arranged number of cycles (0, 40k, 80k, 120k e, 160k), poured with epoxy resin and SEM evaluated to inspect the morphology and to measure the indented area. The use level probability plots of the fatigue data showed overlap between the 2-sided 90% confidence bounds. The calculated Weibull Beta (&#x3B2;) for IA was 1.99 and 1.67 for SB and WC, respectively, pointing out that fatigue accelerated the failure in both groups. This was not the case for the &#x3B2; values for the FA analysis (SB = 1.1 and WC = 0.72), revealing tha the load alone dicted the failure mechanism. Both indenters produced similar pattern of wear on crown surfaces. Fractographic landmarks showed competing failure modes, but partial cone cracks were the most dominant for both groups. The indented area measurements showed statistical difference between groups (SB vs WC) (p < .05). Overall, the WC indenter displayed the largest area than SB, except when 120k was taken into account. The more compliant SB indenter led to similar reliability and failure modes to WC (hypotheses 1 and 2 accepted).
19

Confiabilidade de coroas de dissilicato de lítio com diferentes espessuras sob fadiga / Reliability of lithium disilicate crowns with different thickness under fatigue

Leandro de Moura Martins 13 October 2011 (has links)
Para avaliar a confiabilidade à fadiga de coroas de dissilicato de lítio E.max CAD, com 1mm (monolítica) e 2mm de espessura, foi realizado um preparo para coroa total de um primeiro molar inferior com redução de 1 e 2mm. Réplicas em resina composta do preparo baseado em desenho auxiliado pelo computador (CAD) foram posicionadas em um articulador odontológico para fabricação dos corpos de prova. As coroas monolíticas de 1mm de dissilicato de lítio CAD/CAM (DLM) e coroas de 2.0mm, com 1,5mm de espessura vestibular de dissilicato de lítio CAD/CAM e recoberta com 0.5mm de porcelana (DLV), foram comparadas com coroas de zircônia (Y-TZP) e metalocerâmica (MC). As réplicas de resina composta foram envelhecidas em água por 30 dias e todas coroas cimentadas com cimento resinoso. Após cimentadas, todos os corpos de prova foram envelhecidos em água por 7 dias e testados com carga única ou com fadiga acelerada progressiva. As cargas foram posicionadas na cúspide mésiovestibular (n=21 para cada sistema cerâmico). A probabilidade Weibull e os gráficos de probabilidade (Alta Pro, Reliasoft) foram calculados (Best data fit QCP) e plotados. A evolução da trinca foi acompanhada e os espécimes analisados após o teste. A menor confiabilidade foi observada para o grupo Y-TZP e não houve diferença estatística entre o grupo MC, DLM e DLV. O grupo DLV demonstrou a maior resistência característica (Eta). O modo de fratura do grupo Y-TZP foi a fratura da porcelana de cobertura sem exposição da infraestrutura. O grupo MC apresentou fraturas da porcelana com exposição do metal. Enquanto os grupos DLM e DLV tiveram fraturas catastróficas. Os grupos DLM e DLV apresentaram uma resposta à fadiga semelhante à do grupo MC e melhor que o grupo Y-TZP. / To evaluate the fatigue reliability of monolithic 1mm and thinly veneered 2mm E.max CAD crowns. A preparation reduction of 1 and 2mm for a full crown was made on a first lower molar. The CAD-based preparation was replicated and positioned in a dental articulator for specimen fabrication. Monolithic 1mm lithium disilicate CAD/CAM crowns (DLM) and a 2mm lithium disilicate CAD/CAM with 1.5 mm thick at buccal aspect veneered with 0.5 mm thick of porcelain were compared to zirconia based (Y-TZP) and metaloceramic (MC) crowns. All composite dies were 30-day aged and all crowns were resin cemented to composite dies. After luting, all specimens were aged for 7 days in water and either single loaded to failure or step-stress fatigue tested. Loads were positioned on mesial-buccal cusp (n=21 for each ceramic system). Probability Weibull and Use level probability curves (Alta Pro, Reliasoft) were calculated (Best data fit QCP) and plotted. Crack evolution was followed and specimens were analyzed postmortem. Lower reliability was observed for Y-TZP group and no statistical difference was observed between MC and DLM e DLV groups. DLV group showed the highest characteristic strength (Eta). Fracture mode for Y-TZP group was veneer chipping without core exposition. MC fractures were mostly chipping with metal coping exposure. While the failure for DLM and DLV groups were bulk fracture. Groups DLM and DLV resulted in fatigue response of lithium disilicate comparable to MC and higher than Y-TZP.
20

FATORES RELACIONADOS À PROPORÇÃO DENTAL ANTERIOR DE BOLTON EM INDIVÍDUOS COM OCLUSÃO NORMAL NATURAL / FATORES RELACIONADOS À PROPORÇÃO DENTAL ANTERIOR DE BOLTON EM INDIVÍDUOS COM OCLUSÃO NORMAL NATURAL / Factors related to Bolton s anterior ratio in Brazilians with natural normal occlusion / Factors related to Bolton s anterior ratio in Brazilians with natural normal occlusion

Jóias, Renata Pilli 25 March 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Paginas 1-43.pdf: 4925935 bytes, checksum: 290160b606f5978346daa511574f6a06 (MD5) Previous issue date: 2010-03-25 / The Bolton anterior ratio should be considered in the orthodontic planning in order to excellent occlusion achievement. The aim of this study was to verify wether some factors could be related to Bolton s anterior ratio: upper incisors buccolingual thickness, upper incisors mesiodistal tipping, overjet and overbite, and if there is sexual dimorfism. Thirty-five pairs of dental casts with natural normal occlusion had been evaluated, proceeding from 27 females and 8 male Caucasoid individuals, aged between 13 years old and 17 years and 4 months (mean age: 15 years and 8 months). A digital caliper and a piece of ruler were used for attainment of the measures. The anterior ratio was 77,48% (SD±2,22), showing to be statistically similar to Bolton s, 77,20%, SD±1,65. Based on Pearson s test, just the overbite showed to be related to the anterior ratio. It was not found sexual dimorfism.(AU) / A proporção anterior do tamanho dental de Bolton deve ser considerada no planejamento do caso quando se almeja uma oclusão ótima na finalização do tratamento ortodôntico. Este estudo teve por objetivo verificar se há relação entre as seguintes variáveis e a proporção anterior de Bolton: espessura vestíbulo-lingual dos incisivos superiores, relação entre a angulação dental dos incisivos superiores e o espaço mesiodistal por eles ocupado, sobressaliência e sobremordida, e se há dimorfismo sexual. Foram avaliados 35 pares de modelos em gesso com oclusão normal natural, provenientes de 27 indivíduos do sexo feminino e 8 do masculino, leucodermas, com idade entre 13 anos e 17 anos e 4 meses (idade média: 15 anos e 8 meses). Utilizou-se um paquímetro digital e um fragmento de régua para a obtenção das medidas. A proporção anterior encontrada foi de 77,48% (DP±2,22), estatisticamente semelhante ao valor proposto por Bolton, 77,20% (DP±1,65). De acordo com o teste de Pearson, somente a sobremordida mostrou relação estatisticamente significante com a proporção dental anterior. Não foi observado dimorfismo sexual.(AU)

Page generated in 0.0568 seconds