• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 17
  • 17
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modificação da superficie de fibras de carbono por processo de descarga corona e estudo das caracteristicas de adesão

Ferreira, Sergio Rebello 14 December 2000 (has links)
Orientador: Edison Bittencourt / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-27T09:56:52Z (GMT). No. of bitstreams: 1 Ferreira_SergioRebello_D.pdf: 4420948 bytes, checksum: c582d9be3f113bf5ea7d8123b678c73d (MD5) Previous issue date: 2000 / Resumo: O desempenho de compósitos poliméricos reforçados com fibras de carbono depende das propriedades dos constituintes e, também, da interface entre estes. As características de boa adesão interfacial aumentam a capacidade de transferência de carregamento mecânico do reforço para a matriz polimérica e assegura uma boa integridade do compósito como um todo.Processos de tratamento de superfície por descarga carona têm sido muito utilizado industrialmente na modificação da superfície de materiais poliméricos. Entretanto, poucos estudos tem sido realizados quanto à utilização deste processo no tratamento superficial de fibras de carbono.Este trabalho descreve o processo de descarga corona desenvolvido no Centro Técnico Aeroespacial e Universidade Estadual de Campinas, para a utilização em planta industrial contínua de produção de fibras de carbono.A caracterização química das fibras de carbono obtidas pelo processo corona é feita utilizando-se as técnicas de espectroscopia: na região do infravermelho e Auger. O aspecto físico da superfície dos filamentos é verificado por análise de microscopia eletrônica de varredura.As características termo dinâmicas das superfícies das fibras tais como: ângulo de molhabilidade; energia livre de superfície e seus componentes, dispersivo e polar; e trabalho termo dinâmico de adesão são verificadas e relacionadas com as condições de processo utilizadas.A avaliação do desempenho mecânico das fibras de carbono obtidas é feita utilizando-se técnicas de extração das fibras e análise dinâmico mecânica e flexão de compósitos de resina poliéster reforçados unidirecionalmente com as fibras de carbono obtidas.Finalmente, verifica-se o bom desempenho de adesão e estabelece a relação entre as características termodinâmicas e mecânicas das amostras obtidas / Abstract: The performance of carbon fiber reinforced polymeric composites depends not only on properties of fibers and matrices, but also on the interface between them. The good interfacial adhesion characteristics improve the load transfer from the fibers into matrix and assure good structural integrity of the whole composite.The corona surface treatment process has been widely used industrially to modify polymeric material surfaces. However, there has been very little work reported on this issue when referring to carbon fiber surface.This work describes the corona discharge process developed at Centro Técnico Aeroespacial and Universidade Estadual de Campinas, to be used in industrial process of carbon fiber production.The chemical characterization of the carbon fibers treated by corona process, is obtained using infrared spectroscopy (IR) and Auger spectroscopy techniques (AES). The physical aspect of the filaments are determined by scanning electron microscopy (SEM).The fibers surface chemical characteristics such as: contact angle; surface free energy and its components, dispersive and polar; and work of adhesion are determined and related to the used conditions of the corona process.The mechanical evaluation of the carbon fibers is performed by using pull-out technique and dynamic mechanical analysis (DMA) and four-point bending from the carbon fiber/polyester composites samples.Finally, is verified the adhesive performance and obtained the correlation between mechanical and thermodynamics characteristics ofthe carbon fibers samples / Doutorado / Ciencia e Tecnologia de Materiais / Doutor em Engenharia Química
2

Uma contribuição ao estudo do efeito corona em linhas de transmissão utilizando o metodo de elementos finitos

Miranda, Glassio Costa de 12 August 2018 (has links)
Orientadores: Jose Pissolato Filho, Rodney Rezende Saldanha / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-12T00:49:04Z (GMT). No. of bitstreams: 1 Miranda_GlassioCostade_D.pdf: 7063094 bytes, checksum: 58d5ad6afc1c121009f20780c91d4bef (MD5) Previous issue date: 1994 / Resumo: Neste trabalho, o método de elementos finitos no domínio do tempo - Pointmatched time domain finite element - é utilizado na simulação do efeito corona em linhas de transmissão. As equações diferenciais da linha de transmissão no domínio do tempo são resolvidas através do método de elementos finitos e do esquema "leap-frog". O modelo de Suliciu é utilizado para representar a característica q x v do condutor sob efeito corona. O programa desenvolvido comunica-se com o EMTP (Eletromagnetic Transients Program). A partir da discretização da linha, obtida pelo uso do método de elementos finitos, o efeito corona é introduzido considerando-se a variação da capacitãncia da linha. Através da comparação entre os resultados obtidos com esta metodologia e, os resultados práticos de medição foi possível constatar uma grande coerência entre eles. A metodologia desenvolvida neste trabalho apresenta um pequeno código computacional e rapidez de processamento / Abstract: To determine the effect of corona losses on transmission line transients, the pointmatched Time Domain Finite Element method (TDFE) was used. The time domain transmission line differential equations are solved via the finite element analysis and the leap-frog scheme. The Suliciu's model was used to represent the q x v characteristic of the conductor under corona. The implemented subroutine interfaces with the Electromagnetic Transients Program (EMTP). Using the line discretization inherent in TDFE method, the corona effect is computed by the capacitance variation. Good results were obtained, compared with experimental studies. The advantages of the TDFE method are the small code and processing time / Doutorado / Doutor em Engenharia Elétrica
3

Estudos de propriedades de não tecidos de polipropileno tratados por descarga corona e plasma de rádio frequência / Studies of the properties of polypropylene non-woven treated by corona discharge and radio frequency plasma

Lopes, Selma Aparecida, 1974- 20 August 2018 (has links)
Orientador: João Sinézio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-20T20:46:43Z (GMT). No. of bitstreams: 1 Lopes_SelmaAparecida_M.pdf: 4679717 bytes, checksum: b44b60b38798f2147b5fd6fe7eacc78f (MD5) Previous issue date: 2012 / Resumo: O material polimérico denominado não tecido de polipropileno (NTPP), após receber adequado tratamento químico, tem sido largamente utilizado na indústria têxtil para confecção de produtos de higiene pessoal, fraldas e absorventes descartáveis. Neste sentido o presente trabalho analisa os efeitos das técnicas de descarga corona (atmosfera ambiente) e plasma por radiofrequência (atmosferas de oxigênio (O2), nitrogênio (N2) e argônio (Ar) causados nas propriedades de superfície de amostras de NTPP em função do tempo de tratamento e nas respectivas atmosferas citadas. Recortam-se amostras de NTPP com geometria retangular (10x30mm) e espessura média de 40?m. Após tratamentos por corona e plasma submetem-se as amostras ás técnicas de medidas de ângulo de contato (método da gota séssil), de espectrometria em infravermelho (FTIR/ATR), de microscopia eletrônica exploratória (SEM) e de calorimetria diferencial exploratória (DSC); as quais têm por objetivo caracterizar a superfície do material em relação à molhabilidade, a formação de grupos polares, alterações morfológicas e comportamento de volume, respectivamente. Realizaram-se as medidas em quintuplicatas e dentre os resultados pode-se destacar que (i) o ângulo de contato tende a diminuir com o aumento do tratamento tanto corona quanto plasma, indicando que está ocorrendo aumento da molhabilidade do material, assim como comprovado por cálculos de energia livre de superfície (por exemplo: sem tratamento 18 mN/m e após tratamento 87 mN/m); (ii) as espectrometrias em infravermelho indicam a formação de grupos polares (hidroxílicos e carboxílicos); (iii) os termogramas em DSC indicam que não há alterações entre amostras com e sem tratamento, preservando assim propriedades de volume do material (estabilidade térmica de 0 á 135ºC e Tm=162ºC). Cabe ressaltar que realizaram-se medidas sobre a durabilidade do tratamento corona e os resultados mostram satisfatória durabilidade até 4 dias / Abstract: The polymeric material known as non-woven polypropylene (NTPP) upon receiving suitable chemical treatment has been widely used in the textile industry for the manufacture of personal hygiene products, diapers and disposable absorbent. In this sense the present paper analyzes the effects of corona discharge techniques (ambient atmosphere) and plasma radiofrequency (atmospheres of oxygen (O2), nitrogen (N2) and argon (Ar) caused the surface properties of samples as a function NTPP treatment time and the respective atmospheres cited. Samples were cut out NTPP rectangular geometry (10x30mm) and an average thickness of 40?m. After corona treatment and plasma samples were subjected techniques measures the contact angle (sessile drop method), infrared spectrometry (FTIR/ATR), scanning electron microscopy (SEM) and differential scanning calorimetry (DSC) which are intended to characterize the material surface with respect to wettability, the formation of polar groups, and morphological behavior volume, respectively. There were measures in quintuplicatas and among the results can be noted that (i) the contact angle tends to decrease with the increase in both corona treatment and plasma, indicating that it is an increase of the wettability of the material, as evidenced by calculations of surface free energy (for example, untreated 18 mN/m after treatment 87 mN/m; (ii) infrared spectroscopy indicated the formation of polar groups (hydroxyl and carboxyl); (iii) the DSC thermograms show no charges between treated and untreated samples, thus maintaining properties of the material volume (thermal stability of 0 to 135ºC and Tm=162ºC). It should be noted that measurements were performed on the stability of the corona treatment and the results show satisfactory stability up to 4 days / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
4

Estudo dos efeitos do tratamento corona em superficies de filmes EPDM/PP atraves de medidas de angulo de contato

Alves, Adilson Jose 18 December 2003 (has links)
Orientador : João Sinezio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-04T00:05:59Z (GMT). No. of bitstreams: 1 Alves_AdilsonJose_M.pdf: 2294880 bytes, checksum: f433d4d19527934d2e630b334c3c0dae (MD5) Previous issue date: 2003 / Mestrado / Mestre em Engenharia Química
5

Inclusão das representações de gary e de skilling-umoto em modelos de linhas de transmissão trifásicas: Aplicação em simulações de transitórios eletromagnéticos em sistemas de energia elétrica /

Silva, Rodrigo Cleber da. January 2015 (has links)
Orientador: Sérgio Kurokawa / Banca: Luis Carlos Origa de Oliveira / Banca: Mariangela Carvalho Bovolato / Banca: José Pissolato Filho / Banca: Eduardo Coelho Marques da Costa / Resumo: Neste projeto é desenvolvido um modelo de linha de transmissão trifásica em que possa ser incluído o efeito corona. O modelo será desenvolvido diretamente no domínio do tempo e o mesmo baseia-se na hipótese de que um pequeno segmento de linha trifásica pode ser representado por um circuito constituído por elementos discretos (resistências, indutâncias, capacitâncias e condutâncias). A inserção do efeito corona no modelo da linha será feito com base nos modelos de Gary e de Skilling-Umoto que, até o presente momento, é utilizado para inserir o efeito corona em modelos de linhas de transmissão monofásicas. O modelo a ser desenvolvido poderá ser utilizado para representar linhas trifásicas genéricas, independentemente da geometria da mesma, em simulações de transitórios eletromagnéticos que podem ocorrer em sistemas de energia elétrica. A grande contribuição que resultará do desenvolvimento deste projeto será a disponibilização de um modelo de linha mais completo que os modelos disponíveis atualmente, pois o modelo proposto poderá ser aplicado em qualquer linha trifásica, independentemente da geometria da mesma, e levará em conta o efeito corona (que é responsável por distorções nas formas de ondas de correntes e tensões que se propagam ao longo da linha durante a ocorrência de distúrbios). Um modelo de linha mais precisa que prevê tais distorções, poderá ser útil na análise do sistema de proteção, permitindo um ajuste mais preciso e aumentando a confiabilidade do sistema de energia elétrica / Abstract: In this project will be developed a model for three-phase transmission line that may be included in the corona effect. The model will be developed directly in the time domain and the same is based on the hypothesis that a short segment of three phase line can be represented by a circuit constituted by discrete elements (resistance, inductance, capacitance, and conductance). The insertion of the corona effect in the line model will be based on Gary and Skilling-Umoto models that, until the present time, is used to insert the corona effect in models of transmission lines monophasic. The model to be developed can be utilized to represent generic three-phase lines, regardless of the line geometry, in electromagnetic transient simulations that can occur in electrical power systems. The great contribution that will result from the development of this project will be the making available of a model line more complete than the currently available models, since the proposed model can be applied to any three-phase line, regardless of the geometry of the line, and will take into consideration the corona effect (which is responsible for distortions in the waveforms of voltages and currents that propagate along the line during the occurrence of disturbance). A more accurate model line that provides for such distortions may be useful in the analysis of the protection system, allowing for a more precise fit and increasing the reliability of the electric power system / Doutor
6

Inclusão das representações de gary e de skilling-umoto em modelos de linhas de transmissão trifásicas: Aplicação em simulações de transitórios eletromagnéticos em sistemas de energia elétrica

Silva, Rodrigo Cleber da [UNESP] 25 August 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:29:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-25. Added 1 bitstream(s) on 2016-02-05T18:33:44Z : No. of bitstreams: 1 000857565.pdf: 1726285 bytes, checksum: acf252e5a46ceced5c2b1b64ccd59cc7 (MD5) / Neste projeto é desenvolvido um modelo de linha de transmissão trifásica em que possa ser incluído o efeito corona. O modelo será desenvolvido diretamente no domínio do tempo e o mesmo baseia-se na hipótese de que um pequeno segmento de linha trifásica pode ser representado por um circuito constituído por elementos discretos (resistências, indutâncias, capacitâncias e condutâncias). A inserção do efeito corona no modelo da linha será feito com base nos modelos de Gary e de Skilling-Umoto que, até o presente momento, é utilizado para inserir o efeito corona em modelos de linhas de transmissão monofásicas. O modelo a ser desenvolvido poderá ser utilizado para representar linhas trifásicas genéricas, independentemente da geometria da mesma, em simulações de transitórios eletromagnéticos que podem ocorrer em sistemas de energia elétrica. A grande contribuição que resultará do desenvolvimento deste projeto será a disponibilização de um modelo de linha mais completo que os modelos disponíveis atualmente, pois o modelo proposto poderá ser aplicado em qualquer linha trifásica, independentemente da geometria da mesma, e levará em conta o efeito corona (que é responsável por distorções nas formas de ondas de correntes e tensões que se propagam ao longo da linha durante a ocorrência de distúrbios). Um modelo de linha mais precisa que prevê tais distorções, poderá ser útil na análise do sistema de proteção, permitindo um ajuste mais preciso e aumentando a confiabilidade do sistema de energia elétrica / In this project will be developed a model for three-phase transmission line that may be included in the corona effect. The model will be developed directly in the time domain and the same is based on the hypothesis that a short segment of three phase line can be represented by a circuit constituted by discrete elements (resistance, inductance, capacitance, and conductance). The insertion of the corona effect in the line model will be based on Gary and Skilling-Umoto models that, until the present time, is used to insert the corona effect in models of transmission lines monophasic. The model to be developed can be utilized to represent generic three-phase lines, regardless of the line geometry, in electromagnetic transient simulations that can occur in electrical power systems. The great contribution that will result from the development of this project will be the making available of a model line more complete than the currently available models, since the proposed model can be applied to any three-phase line, regardless of the geometry of the line, and will take into consideration the corona effect (which is responsible for distortions in the waveforms of voltages and currents that propagate along the line during the occurrence of disturbance). A more accurate model line that provides for such distortions may be useful in the analysis of the protection system, allowing for a more precise fit and increasing the reliability of the electric power system
7

Avaliação do efeito do tratamento corona no desempenho de aditivos Anti-UV utilizados em filmes termoplásticos

Duarte, Glaucea Warmeling 22 May 2014 (has links)
Dissertação apresentada ao Programa de Pós-Graduação em Ciência e Engenharia de Materiais da Universidade do Extremo Sul Catarinense - UNESC, para a obtenção do título de Mestre em Ciência e Engenharia de Materiais. / Several advances have occurred in the polymer industry in the last decade, among them, innovations in the use of additives, which enable the use of polymers in several areas. However, much remains to be studied regarding the behavior of these additives when exposed to transformation processes in which the polymers are normally subjected. Thus, this study aims to evaluate the structural modifications in stabilizing additives present in polymeric films, when subjected to corona treatment. Four different UV stabilizing additives were evaluated: benzophenone, benzotriazole, triazine and sebacate. The additives films were produced using an experimental design of mixtures by spin coating technique and they were subjected to ultraviolet radiation exposures and corona treatment. Analyzing the results obtained it was realized that the only additive that resisted to the treatment conditions imposed was benzotriazole, maintaining the absorption of ultraviolet radiation after treatment and continuing to protect the polymer from degradation. The other additives suffered degradation processes and the absorption of ultraviolet radiation presented earlier, ceased to exist. / Diversos avanços ocorreram na indústria polimérica na última década, podendo-se citar, dentre eles, inovações no uso de aditivos que possibilitaram a utilização de polímeros nas mais diversas áreas. Porém, muito ainda deve ser estudado quanto ao comportamento desses aditivos quando expostos aos processos de transformação aos quais os polímeros são submetidos. Sendo assim, o presente trabalho tem o objetivo de avaliar as mudanças ocorridas nos aditivos estabilizantes, presentes em filmes poliméricos, quando sujeitos a exposição ao tratamento corona. Quatro diferentes aditivos estabilizantes de UV foram avaliados: benzofenona, benzotriazol, sebacato e triazina. Os filmes aditivados foram produzidos segundo um planejamento experimental de misturas pela técnica de spin coating e os mesmos foram submetidos a exposições a radiação ultravioleta e ao tratamento corona. Através da análise dos resultados percebeu-se que o único aditivo que resistiu às condições de tratamento impostas foi o benzotriazol, não deixando de absorver radiação ultravioleta após os tratamentos, continuando a proteger o polímero e evitando sua degradação. Os demais aditivos sofreram processos de degradação e a absorção de radiação ultravioleta apresentada anteriormente às exposições deixou de existir.
8

Efeitos da descarga corona em superfície de polipropileno em temperatura ambiente e acima / Effects of corona discharge on polypropylene surface at room temperature and above

Sena, Hildo Costa de 17 August 2018 (has links)
Orientador: João Sinézio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-17T16:49:59Z (GMT). No. of bitstreams: 1 Sena_HildoCostade_M.pdf: 22003439 bytes, checksum: 1eca2b2806567e926cea6f94abd18776 (MD5) Previous issue date: 2011 / Resumo: Este trabalho avalia o efeito do tratamento por descarga corona em temperatura ambiente e acima para promover aumento da energia de superfície em filmes de polipropileno (PP). Submeteram-se amostras de polipropileno ao tratamento corona em sistema com geometria ponta-plano e utilizou-se de tensão de polarização dos eletrodos em 5kV . Avaliaram-se os efeitos do tratamento corona através de medidas de ângulo de contato pelo método da gota séssil, em função dos parâmetros: tempo de tratamento corona (2s a 90s), temperatura das amostras de polipropileno (25_C e 55_C) e distância entre os eletrodos (3mm e 5mm). Os resultados indicam influência significativa do tempo de tratamento corona e da distância intereletrodos. Ademais, o tratamento corona aumenta a energia de superfície dos filmes observada através da diminuição do valor do ângulo de contato entre amostra e gota d'água (inicialmente 88_ sem tratamento e 50_ após corona com 3mm de distância entre os eletrodos). Dentre os parâmetros e condições estudadas a temperatura não apresenta influência nos valores de ângulo de contato a fim de mudar a energia de superfície dos filmes. Em adição as medidas de ângulo de contato, medem-se propriedades físico-químicas da superfície do PP através da obtenção dos espectros dos filmes por espectrometria de infravermelho com transformações de Fourier (FT-IR) e de micrografias obtidas por microscopia eletrônica exploratória (MEV). A energia de superfície (antes e após tratamento corona) foi determinada utilizando-se os seguintes métodos: tensão superficial crítica (c), equação de estado (EE) e as aproximações de Owens/ Wendt (OW), Wu (Wu) e van Oss/ Chaudhury/ Good (VCG). A partir destes métodos encontra-se que: foram observadas diferenças entre os espectros de FT-IR obtidos nas diferentes condições de tratamento estudadas quando associadas a modificação por corona sob temperatura acima da ambiente (55_C _ 2_C). Alterações na topografia dos filmes de PP foram observadas após tratamento por descarga corona através da formação de grânulos, depressões, eriçamento e protuberâncias na superfície destes. Melhorias na energia livre superficial dos filmes de PP foram observadas após tratamento corona e variou aproximadamente de 36,9mN=m para 47,9mN=m em filmes sem tratamento superficial e após 10s de tratamento por descarga corona quando determinada através da aproximação de VCG, respectivamente / Abstract: The present study evaluates the effect of corona discharge treatment at room temperature and above in order to promote an increase of surface energy of polypropylene films. Polypropylene samples were subjected to corona treatment in tip-plane geometry system using bias voltage of 5kV between the electrodes. The effects of corona treatment were assessed by contact angle measurements using the sessile drop method, taking in account the following parameters: corona treatment time (2s to 90s), temperature of polypropylene samples (25_C and 55_C) and distance between the electrodes (3mm and 5mm). The results indicate significant influence of treatment time and the distance between the electrodes. Moreover, the corona treatment increases the surface energy of the films which was observed by decreasing the value of the contact angle between thesample and drop of water (initially 88_ without treatment and 50_ after corona with 3mm gap between the electrodes). Among the parameters and conditions studied, the temperature does not influence the values of contact angle in order to change the surface energy of the films. In addition the measures of contact angle, were carried out measures of physicochemical properties of the PP surface by obtaining the spectra of the films by infrared spectrometry with Fourier transformed (FT-IR) and micrographs obtained by scanning electron microscopy (SEM). The surface energy (before and after corona treatment) was determined using the following methods: critical surface tension (c), equation of state (EE) and approaches from Owens/ Wendt (OW), Wu (Wu) and van Oss/ Chaudhury/ Good (VCG). From these methods is turning out that: there were differences between the spectra obtained at different FT-IR treatment conditions studied when associate the corona modification at above room temperature (55_C _ 2_C). Changes in the topography of the films PP were observed after treatment by corona discharge due to formation of granules, depressions, bristling and bumps on their surface. Improvements in surface free energy of the PP films were observed after corona treatment, around from about 36,9mN=m in films without surface treatment up to 47,9mN=m after 10s of corona discharge when determined by VCG approach / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
9

Modificação de superficie da borracha natural por descarga corona / Surface modification of natural rubber by corona discharge

Buzeto, Fabricio Andre 18 December 2007 (has links)
Orientador: João Sinezio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-11T18:17:28Z (GMT). No. of bitstreams: 1 Buzeto_FabricioAndre_M.pdf: 5022514 bytes, checksum: da17a266de578a2060bb68a4ba3a873d (MD5) Previous issue date: 2007 / Resumo: Estudos das modificações superficiais de polímeros, causadas por descarga corona, são desenvolvidos com o objetivo de mudar as propriedades hidrofóbicas apresentadas por esses materiais, melhorando suas propriedades superficiais sem alterar suas propriedades mecânicas. No presente estudo, realizou-se, alterações na superfície da borracha natural, por tratamento corona de configuração ponta/plano com potência de 5 kV, visando, num segundo momento, a facilitação da incorporação de cargas com caráter hidrofílico à borracha natural. Um planejamento fatorial 22 foi utilizado para a análise dos resultados obtidos por medidas de ângulo de contato, tendo como objetivo a determinação do tempo e altura ótimos para a diminuição do ângulo de contato medido na superfície do polímero em relação à água destilada. Utilizaram-se técnicas complementares como FTIR/ATR, para a determinação das alterações físico-químicas ocorridas na superfície da borracha, bem como, análises térmicas da borracha natural visando à sustentação da não ocorrência de modificações na estrutura polimérica da borracha natural, tais como, reticulações. Através da técnica de microscopia ótica, foi possível verificar que para alturas menores que 2 mm, a superfície da borracha sofre degradação causada pela intensidade das descargas / Abstract: Studies of the superficial modifications of polymers, caused by corona discharges, are developed with the objective to change the hydrophobic properties presented by these materials, improving their superficial properties without changing their mechanical properties. In the present study, superficial modifications were carried out in the natural rubber, for corona treatment from needles-plane electrode system configuration with power of 5 kV, aiming, on a second moment, the facilitation of the incorporation of fillers with hydrophilic characteristic into the natural rubber. A factorial planning 22 was used on the analysis of the results obtained by contact angle measures, taking as an objective the determination of the best time and height for the reduction of the contact angle measured in the polymer surface regarding the distilled water. Complementary techniques were used, like the FTIR/ATR, to determine the chemical-physic alterations taken place in the rubber surface, as well, thermal studies of the natural rubber aiming for sustenance of not-incident modifications in the internal polymeric structure of the natural rubber, such as, reticulations. Through the optical microscopy technique, it was possible to confirm that, for heights less than 2 mm, the rubber surface suffers degradation caused by the intensity of the applied electric charges. / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
10

Analise da superficie de polimeros pos-tratamento corona

Sellin, Noeli 21 November 2002 (has links)
Orientador: João Sinezio de Carvalho Campos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-02T14:17:27Z (GMT). No. of bitstreams: 1 Sellin_Noeli_D.pdf: 7024979 bytes, checksum: 1a92e73ed7d246d0fa41c67995311407 (MD5) Previous issue date: 2002 / Resumo: Os polímeros, em especial as poliolefinas, apresentam baixa energia livre de superfície, caracterizada pela adesão relativamente fraca a outros materiais. Para resolver este problema, suas superfícies são tratadas por diversas técnicas, destacando-se a descarga corona, amplamente utilizada na indústria. Muitos problemas pós-tratamento surgem por falta de entendimento das propriedades de superfície e sua relação com a adesão. Neste trabalho, estudam-se as modificações causadas na superfície de filmes de polipropileno (PP) isotático tratados por descarga corona. Para isto, os filmes são tratados sob condições ambientes controladas e após o tratamento, parte das amostras é armazenada a diferentes temperaturas, sendo que as armazenadas em temperatura ambiente são retratadas; outra parte é lavada com solventes e também armazenada (temperatura ambiente). As superfícies destes filmes são caracterizadas através de espectroscopia FTIR/ATR, microscopia de força atômica (AFM), ângulo de contato (8), DSC e teste de descolagem Peel. O tratamento por descarga corona induz a formação de grupos polares contendo oxigênio na superfície dos filmes e mudanças na topografia, tais como, o aparecimento de novas estruturas, aumento da rugosidade e dimensão fractal, resultando no aumento da energia livre superficial, molhabilidade e melhoria na adesão. Tratamento estendido promove a formação de material oxidado de baixa massa molar, o qual é facilmente removido pela lavagem com solvente. O envelhecimento ambiente dos filmes tratados e dos tratados/lavados diminui ligeiramente a força de adesão dos filmes em conseqüência da reorientação (lenta) dos grupos formados na superfície e diminuição da energia livre superficial e da molhabilidade. Envelhecimento acima de 60°C acelera os efeitos observados no envelhecimento ambiente. O retratamento dos filmes tratados recupera as propriedades superficiais perdidas após o envelhecimento / Abstract: Many polymer films (polyolefins) present low energy surfaces, characterised by their relatively weak adhesion to other materiais. Numerous methods have been developed to modify polymer surfaces. Among these methods, corona discharge treatment, is widely used in industry. In this work, the surface modification of corona treated polypropylene films (PP) is studied. The films are treated by corona discharge in controlled ambient conditions and after treatment, some samples are aged under different temperatures; other samples are washed by immersion in solvent (acetone and water) and also aged. Their surfaces are characterised by FTIRlATR spectroscopy, atomic force microscopy (AFM), contact angle (8), differential scanning calorimeter (DSC) and peel tests. Discharge treatment introduces oxygen polar groups into the films surface and dramatic change in the topography (new structures, increase in the roughness and fractal dimension), resulting in increased wettability and much enhanced adhesion. Extended oxidation results in the formation of low molecular weight oxidised material (LMWOM), which is easily removed by washing with solvent. For corona treated PP films ageing at ambient temperature, only a slight decrease in adhesion is observed. This decrease is attributed to the reorientation of oxidised functionalities within the surface region and to slight decrease in the surface free energy and wettability. At elevated storage temperatures, migration of oxidised species out of the surface region occurs leading to significant decreases in the wettability and a loss of surface oxidation. The treated films surface properties lost after ageing are restored by re-treatment / Doutorado / Ciencia e Tecnologia de Materiais / Doutor em Engenharia Química

Page generated in 0.1002 seconds