• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 752
  • 33
  • 12
  • 7
  • 7
  • 7
  • 7
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 808
  • 405
  • 221
  • 198
  • 194
  • 187
  • 139
  • 109
  • 108
  • 107
  • 107
  • 104
  • 97
  • 89
  • 83
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Quantificação do transporte longitudinal a patir de dados de concentração de sedimentos em suspensão, Tramandaí-RS

Ma, Tomas Tak Min January 2013 (has links)
A proposta deste trabalho consiste na aplicação de dados de concentração de sedimentos em suspensão, na zona de arrebentação das ondas, para quantificar o transporte longitudinal que ocorre no Litoral Norte do Estado do Rio Grande do Sul – Brasil. Os dados de suspensão foram coletados a partir de uma estrutura construída perpendicularmente à linha de praia (Plataforma de Pesca de Tramandaí). As amostragens foram feitas, de modo a cobrir a zona de arrebentação, para diferentes distâncias do fundo. Verificou-se ao longo do trabalho, que o valor médio da concentração de sedimentos em suspensão (C) em quilogramas massa por metro linear de praia, apresentou como propriedade principal, uma forte proporcionalidade com a área da seção (S), ao longo do perfil, (C(kg;m) = 3,10-4 S2 + 0,1173 S). Utilizando esta particularidade, foi proposto um modelo utilizando as equações do perfil de equilíbrio de Dean (1977) para gerar o perfil de fundo. O limite deste foi obtido pela profundidade do ponto de arrebentação, determinada através da metodologia proposta por Herbich (2000). A área foi obtida por integração da equação de Dean, entre a linha de praia e o limite da zona de arrebentação. Através da propriedade citada acima, obteve-se a concentração total de sedimento entre a linha de praia e a arrebentação. O fluxo de sedimento foi obtido pelo produto da concentração total pela velocidade de corrente obtida pela aplicação da equação de Longuet-Higgins (1970). Os dados de ondas utilizados foram obtidos a partir de previsões fornecidas pela NOAA (National Oceanic Atmospheric Administration), para o ano de 2009. Observou-se ainda, que a direção do transporte resultante foi de SW para NW, em acordo com observações geológicas. O valor encontrado foi 314.799,10 m3/ano. / The purpose of this work is the application of data of suspended sediment concentration in the breaking zone waves, to quantify the longitudinal transport that occurs on the northern coast of Rio Grande do Sul - Brazil. The data of suspended sediment were collected from a structure built perpendicular to the beach line (Fishing Platform Tramandaí). The samples were taken so as to cover the breaking zone for different distances from the bottom. It was found during the study, the mean value of the suspended sediment concentration (C) in kg weight per linear meter of sand, presented as a main property, a strong proportionality to the sectional area (S) along the profile (C (kg/m) = 3.10-4 S2 + 0,1173S). Utilizing this characteristic, we propose a model using Dean’s (1977) equations of equilibrium profile, to generate the bottom profile. The limit of this was obtained by the depth of the point of breaking, determined using the methodology proposed by Herbich (2000). The area was obtained by integrating the equation Dean between the beach line and the limit of the breaking zone. Through the property mentioned above, there was obtained a total concentration of sediment between the beach line and breaking zone. The flux of sediment was obtained by the product of total concentration and the velocity of flux obtained by applying the equation Longuets-Higgins (1970). The wave data used were obtained from forecasts provided by NOAA (National Oceanic Atmospheric Administration) for the year 2009. It was also observed that the direction of transport resulting from SW to NW, in agreement with geological observations. The value found was 314799,10 m3/year.
142

Aprendizagem de conceitos físicos relacionados com circuitos elétricos em regime de corrente alternada com uso da placa Arduino

Dröse Neto, Breno January 2013 (has links)
O objetivo deste trabalho foi investigar as dificuldades encontradas pelos alunos na aprendizagem de circuitos elétricos em regime de corrente alternada (CA). Especificamente investigamos: i) dificuldades de aprendizagem em relação aos conceitos de reatância e impedância presentes em circuitos RLC de CA; ii) a contribuição da visualização da diferença de fase entre a tensão no capacitor/indutor e a tensão da fonte de CA na compreensão dos processos físicos envolvidos nesses elementos do circuitos e iii) a contribuição da análise da tensão nos elementos presentes em circuitos elétricos (resistivos, RC, RL e RLC) em tempo real através da placa Arduino para o entendimento do comportamento desses em regime de corrente contínua e alternada. Para tanto foi desenvolvido, amparado na Teoria da Aprendizagem Significativa de Ausubel, um material didático constituído por: i) um aparato experimental que, por meio de uma placa Arduino conectada a um computador, fornece gráficos em tempo real do comportamento da tensão em função do tempo nos diferentes tipos de circuitos trabalhados; ii) questionários online, para a determinação do conhecimento prévio dos alunos, cujas respostas serviram para o professor orientar a sua exposição em aula, à semelhança do que ocorre na estratégia de “Ensino sob Medida” (EsM) e iii) e guias de atividades para que os alunos, trabalhando em aula em pequenos grupos com a metodologia “Predizer, Interagir e Explicar” (P.I.E.), explorassem os circuitos elétricos que construíam com a placa Arduino. O equipamento experimental foi utilizado pelo professor em pequenas demonstrações e, especialmente, pelos alunos em todas as atividades realizadas em pequenos grupos, na etapa Interagir do P.I.E. Foram realizados dois estudos: o primeiro, do tipo piloto e duração de 9h, com alunos do curso de licenciatura em Física da UNIPAMPA teve o objetivo de testar e melhor material didático desenvolvido; já o segundo, um estudo de caso exploratório com alunos da Física (Bacharelado e Licenciatura) da UFRGS matriculados na disciplina de Eletrônica básica, com duração de 6 horas, teve o objetivo de responder às questões propostas na pesquisa. Em ambos os estudos todos os alunos já haviam cursado a disciplina de Física III, Eletromagnetismo, tendo os conhecimentos básicos necessários para a aprendizagem dos conceitos de impedância e reatância. Os resultados da nossa análise qualitativa mostram que os estudantes eram capazes de argumentar sobre a diferença de fase entre a tensão nos elementos constituintes do circuito RLC de CA, inclusive dois meses após o término das atividades. De modo geral, para os aprendizes o capacitor/indutor não é um agente capaz de restringir a corrente elétrica em um circuito de CA, assim como ignoram a contribuição do resistor para a impedância. Os resultados apontam que a visualização da diferença de fase entre a tensão no capacitor/indutor seja um agente facilitador da aprendizagem dos processos físicos envolvidos nesses elementos, bem como auxiliam no entendimento e argumentação sobre a fase existente entre os componentes do circuito RLC de CA. A principal contribuição da análise através da placa Arduino foi seu rápido feedback e fácil manuseio, que aliado à metodologia adotada auxiliaram no entendimento das questões propostas aos alunos. Entretanto, salientamos que os resultados são preliminares e que mais esforços deverão ser envidados para subsidiar as conclusões da presente pesquisa. / The purpose of this study is to investigate the difficulties related to the learning of basic concepts of alternating current circuits. In particular, we investigated: i) learning difficulties associated with the concepts of reactance and impedance in RLC circuits (AC); ii) the contribution of real-time graphical visualization of phase’s difference between the voltage on the capacitor/inductor and on the AC source to understand the physical processes involved in the electric elements the circuits and iii) the contribution of a real-time voltage analysis using an Arduino board to compare the behavior of electrical elements in a circuit whether with direct or alternating current source. To answer our research questions a didactical material was developed based on Ausubel's Meaningful Learning Theory and it consists of: i) an experimental setup (Arduino board connected to a computer); ii) online questionnaires to detect the student’s misconceptions and iii) student’s activity guides using the "Predict, Interact and Explain" methodology to explore electrical circuits mounted on a protoboard. The experimental equipment was used by the teacher in short demonstrations, and by the students while developing experimental activities in small groups. A pilot study was conducted with undergraduate Physics students to test and improve the developed instructional material. This study was conducted at the Federal University of Pampa (UNIPAMPA-Brazil) and lasted 9 hours. Then an exploratory case study to answer the research questions was conducted with undergraduate physics majors at the Federal University of Rio Grande do Sul (UFRGS-Brazil) enrolled in a basic electronics course. This study lasted 6 hours. In both studies, all students had the basic knowledge needed for learning the concepts of impedance and reactance. The qualitative results show that students were able to argue on the phase difference between the voltages on the elements of the AC RLC circuit, even two months after the end of the activities. In general, the apprentices considered that the capacitor/inductor does not restrict the electric current in an AC circuit, as well as ignore the resistor's contribution to the impedance. The results suggest that the real-time graphical visualization of the voltage on the capacitor/inductor helps the students to understand the physical processes involved in these elements and, specifically, to understand the phase’s difference between the components of the AC RLC circuit. The main contribution of the Arduino board is related to its quick feedback and easy handling. This, combined with the didactical methodology we used, helped to foster students’ understanding. However, our results are preliminary and more efforts should be made to support the conclusions of this research.
143

A estimulação transcraniana por corrente contínua como coadjuvante à dieta hipocalórica para a perda de peso e controle metabólico no excesso de peso

Araújo, Carina de January 2017 (has links)
A estimulação transcraniana por corrente contínua (ETCC) é uma técnica de neuromodulação não-invasiva que permite um método seguro, indolor, de baixo custo e minimamente restritivo para a indução de neuroplasticidade, ou seja, modular a função cortical e influenciar os processos cognitivos. Consiste na aplicação de uma corrente elétrica fraca e constante por meio de dois eletrodos estrategicamente posicionados no couro cabeludo, a fim de proporcionar uma modulação dependente de polaridade (despolarização ou hiperpolarização). Essa técnica vem sendo amplamente investigada no contexto do comportamento alimentar, por seu papel na regulação do apetite e do consumo alimentar. Estudos apontam que a fissura por alimentos, ou o desejo incontrolável em consumir determinados alimentos (food craving), está intimamente associada ao ganho de peso, principalmente quando considerada a teoria de que alguns alimentos altamente palatáveis funcionem como substâncias de adição, como as drogas. Também sugerem que a modificação na atividade de circuitos cerebrais na região do córtex pré-frontal dorsolateral (CPFDL) poderia gerar benefícios terapêuticos no tratamento da obesidade, tendo em vista que esta região cerebral foi previamente associada à redução do food craving. Neste sentido, a ETCC sobre o CPFDL emerge como uma possível técnica coadjuvante ao tratamento do sobrepeso e da obesidade. Até o momento não existem estudos que tenham avaliado os efeitos da ETCC associados a um programa de emagrecimento em pessoas com excesso de peso. Portanto, essa dissertação teve por objetivos: 1) revisar os parâmetros técnicos da ETCC, seus mecanismos de ação e sua segurança; 2) integrar esse método no contexto da obesidade e do excesso de peso; e 3) analisar o efeito da ETCC associada a uma dieta hipocalórica sobre a perda de peso em indivíduos com sobrepeso ou obesidade. Em um ensaio clínico randomizado duplo-cego e controlado por placebo, 10 indivíduos completaram quatro semanas (20 sessões, cinco dias consecutivos por semana) de ETCC com dose fixa de 2 mA por 20 min, sobre o CPFDL direito, associada a uma dieta hipocalórica para perda de peso. Os participantes foram randomizados na razão de 1:1 e estratificados por sexo em ETCC ativo ou ETCC placebo. Ao final do estudo, o grupo ETCC ativo alcançou menor índice de massa corporal (IMC) do que o grupo ETCC placebo (p=0,002), sugerindo que a ETCC ativa repetitiva sobre o CPFDL direito pode ser uma promissora técnica não-invasiva para incrementar a redução de peso em indivíduos com sobrepeso ou obesidade e em tratamento com dieta hipocalórica. / Transcranial direct current stimulation (tDCS) is a noninvasive neuromodulation technique that allows a safe, painless, low cost and minimally restrictive method to induce neuroplasticity modulating cortical function and influence in cognitive processes. It consists of the application of a weak and constant electric current through two electrodes, strategically positioned in the scalp, in order to provide a polarity-dependent modulation (depolarization or hyperpolarization). This technique has been widely investigated in the context of eating behavioral, due to its role in regulating appetite and food consumption. Studies have shown that food craving is closely associated with weight gain, especially when considered the theory that some highly palatable foods function as addition substances, such as drugs. They also suggest that the modification in brain circuits activity at the dorsolateral prefrontal cortex (DLPFC) could lead to therapeutic benefits in obesity treatment, considering that this brain region was previously associated whit reduced food craving. In this way, the tDCS on DLPFC emerges as a possible adjunct to the treatment of overweight and obesity. Despite the above, there are no studies to date evaluating the effects of tDCS associated with a weight loss program in overweight people. Therefore, this work had as objectives: 1) review the technical parameters of the tDCS, its mechanisms of action and safety; 2) integrate this method in the context of overweight and obesity; and 3) analyze the effect of tDCS associated with a hypocaloric diet on weight loss in overweight or obese individuals. In this double blind, placebo-controlled, randomized clinical trial, 10 individuals completed a four-week (20 sessions; five consecutive days/week) of fixed-dose tDCS (2mA, 20 min) delivered over the right DLPFC (rDLPFC) associated whit a weight loss treatment. Participants were randomly assigned (1:1) and stratified by sex to active tDCS or sham tDCS. At the end of the study, reduction in body mass index (BMI) was greater in the active than in the sham group (p=0.002), that repetitive active tDCS over rDLPFC may be a promising non-invasive technique that could be used to increase BMI reduction in overweight or obese individuals on a low-calorie diet.
144

Modelagem e simulação da proteção de alimentadores de distribuição utilizando softwares tipo EMTP

Conceição, Everaldo Nonato da 10 August 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-01-03T11:18:02Z No. of bitstreams: 1 2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2013-03-01T13:42:05Z (GMT) No. of bitstreams: 1 2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Made available in DSpace on 2013-03-01T13:42:05Z (GMT). No. of bitstreams: 1 2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Neste trabalho é desenvolvido e implementado modelos de dispositivos usados na proteção de sobrecorrente de redes de distribuição como: religadores, seccionalizadores, fusíveis, relés digitais e transformadores de corrente. Nesse sentido realiza-se uma revisão teórica abordando a proteção de sobrecorrente da rede de distribuição, com foco nos ajustes, coordenação, e teoria de relé digital. Apresenta-se um memorial de cálculo de dimensionamento dos elementos de proteção de acordo com os parâmetros elétricos e físicos da rede de distribuição. A implementação computacional foi elaborada utilizando como ferramenta de trabalho o ATP (Alternative Transients Program) em conjunto com a MODELS para simular, modelar, visualizar o comportamento da proteção por sobrecorrente da rede de distribuição. Realizam-se inúmeros testes de curtos-circuitos (monofásicos, bifásicos, trifásicos) em vários pontos da rede de distribuição para validar os modelos desenvolvidos e verificar o desempenho da proteção por sobrecorrente. São avaliados os curtos-circuitos, os ajustes e a coordenação que podem afetar na atuação da proteção do sistema. Os resultados mostraram que se pode fazer, de modo satisfatório, consistente, a proteção de uma rede de distribuição com o uso da modelagem e simulação utilizando software ATP/MODELS. O estudo desenvolvido neste trabalho pode contribuir na solução de problemas de ajustes, coordenação e análise do comportamento da rede de distribuição na presença de falta provocada por uma sobrecorrente. ______________________________________________________________________________ ABSTRACT / This work develops and implements models for overcurrent protection devices such as recloser, sectionalizers, digital relays, fuses and current transformers. A literature review on overcurrent protection of electric distribution networks is carried out, focusing on settings, coordination and digital relay theory. Based on electric and physical parameters of such networks, we present a memorial sizing calculation of protection devices. As for tools, we used the ATP (Alternative Transients Program) and its MODELS interface in order to model, simulate and visualize the behavior of the overcurrent protection mechanism applied to distribution networks. Aiming to validate the developed models and evaluate the performance of the overcurrent protection system, we analyze a wide variety of faults in a distribution network. Specifically, we evaluated short circuit conditions, proper settings and coordination that can affect the operation of system protection. The obtained results show that it is possible to consistently evaluate the performance of distribution network protection by using the ATP/MODELS application. In summary, the contributions in this work will be useful in adjusting, coordinating and evaluating the behavior of the electric distribution network under fault due to overcurrent.
145

Estudo dos fatores de risco para infecção de corrente sanguínea no peroperatório de cirurgia cardíaca pediátrica

Teixeira, Maria Aparecida dos Santos 18 October 2010 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Medicina, 2010. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-09-08T20:30:30Z No. of bitstreams: 1 2010_MariaAparecidadosSantosTeixeira.pdf: 490574 bytes, checksum: 07f8110f7af2e267b99ec62854309bcc (MD5) / Approved for entry into archive by LUCIANA SETUBAL MARQUES DA SILVA(lucianasetubal@bce.unb.br) on 2011-09-20T15:27:26Z (GMT) No. of bitstreams: 1 2010_MariaAparecidadosSantosTeixeira.pdf: 490574 bytes, checksum: 07f8110f7af2e267b99ec62854309bcc (MD5) / Made available in DSpace on 2011-09-20T15:27:26Z (GMT). No. of bitstreams: 1 2010_MariaAparecidadosSantosTeixeira.pdf: 490574 bytes, checksum: 07f8110f7af2e267b99ec62854309bcc (MD5) / Introdução e Objetivos – Pacientes pediátricos em peroperatório de cirurgia cardíaca estão especialmente expostos à complicações infecciosas, sobretudo infecção de corrente sanguínea (ICS). Apesar do crescente aumento do número de unidades de terapia intensiva (UTIs) cardiopediátricas, contudo, ainda são poucos os estudos que buscam identificar os fatores de risco para o surgimento de ICS. O presente estudo teve como objetivos determinar quais os principais fatores de risco para o desenvolvimento de ICS, analisando características clínicas como idade e doença de base; e aspectos relacionados à cirurgia cardíaca, como tempo de circulação extracorpórea (CEC) e uso de cateter venoso central; e se houve associação entre óbito e ICS. Metodologia – Trata-se de coorte retrospectiva longitudinal, realizada na UTI de Cardiopediatria de um serviço terciário, entre fevereiro de 2005 e junho de 2008. Os critérios de inclusão foram: idade entre 0 e 16 anos, cirurgia cardíaca realizada naquela admissão, tempo mínimo de permanência de 48 horas na unidade e presença de pelo menos um acesso venoso central no pós-operatório imediato. Apenas o primeiro episódio de ICS foi considerado. Foram aplicadas análises univariadas e multivariadas, para identificar associação entre variáveis clínicas e cirúrgicas com os desfechos: ICS e óbito. Significância estatística foi definida por P < 0,05. Para análise dos dados foi utilizado pacote estatístico SPSS versão 17.0. Resultados - Foram estudados 386 pacientes, com mediana de idade de 16 meses, sendo 195 do gênero masculino (51%) e 191 do gênero feminino (49%). Houve 46 pacientes (12%) neonatais, e a faixa de um a oito anos foi a mais prevalente, com 171 casos (44%). O grupo mais encontrado de cardiopatias foi shunt esquerda-direita, com 170 casos (44%), e as categorias mais observadas do escore de RACHS-1, foram II e III. Utilizou-se CEC em 270 pacientes (70%), com tempo médio de duração de 114 ± 53 minutos. Em 62 (16%) pacientes houve fechamento tardio do esterno. Apresentavam dois ou mais cateteres venosos centrais no pós-operatório imediato 47 (12,2%) pacientes. A taxa de incidência de ICS resultou 7,7% (30 episódios em 386 pacientes, havendo confirmação microbiológica em 14 casos e com predominância de gram negativos (86%). A variável “cada 10 minutos de tempo de CEC” (P = 0,02) apresentou associação independente com ICS, com ponto de corte maior ou igual a 124 minutos identificado na curva ROC. A incidência de ICS foi maior no grupo de maior complexidade e com esterno aberto (P < 0,001). A letalidade na amostra avaliada foi de 11% (43 óbitos em 386 pacientes) e “tempo de CEC” esteve significativamente associada ao óbito: (P = 0,01). A incidência de óbito foi maior no grupo com ICS (P = 0,005), apesar de não se observar associação significativa entre ICS e óbito na análise multivariada. Conclusão – Cateter venoso central não mostrou valor preditor independente para o desenvolvimento de ICS. “Tempo de CEC”, embora pudesse refletir gravidade dos pacientes, esteve fortemente associada à ocorrência de ICS no presente estudo, sobretudo a partir dos 124 minutos de duração. A ICS não foi preditora independente para óbito na população analisada. _______________________________________________________________________________ ABSTRACT / Background and Objectives - Pediatric patients undergoing cardiac surgery are particularly prompted to infectious complications, mainly bloodstream infection (BSI). Despite of crescent amount of pediatric cardiac intensive care units (PICU), there are few studies about risk factors to BSI development. The aim of this study was to identify major risk factors for BSI, evaluating clinical characteristics as age and underlying sickness; and cardiac surgical aspects as cardiopulmonary bypass duration and central venous catheter use; and if there was association between death and BSI. Methods – We conducted a retrospective longitudinal cohort study, in a tertiary care institution’s PICU, between February, 2005 and June, 2008. Inclusion criteria were the following: age between 0 and 16 years, cardiac surgery performed in that admission, ICU stay for at least 48 hours and at least one central venous catheter on immediate postoperative time. Only the first BSI episode was considered. Univariate and multivariate conditional logistic regression analyses were used to identify association between clinical and surgical variables with outcomes: BSI and death. P value < 0,05 was statistically significant. SPSS version 17.0 was used for statistical analysis. Results – Three hundred and eighty six patients, with median age of 16 months, being 195 male (51%). There were 46 neonatal patients (12%), and age between one and eight years was the most prevalent, being 171 patients (44%). The most common cardiac congenital malformations were left-to-right shunt, with 140 patients (44%), and most prevalent risk categories RACHS-1, were II and III. Cardiopulmonary bypass was used in 270 (70%) patients, with mean duration of time of 114 ± 53 minutes. In 62 (16%) patients open chest was performed. Forty seven (12,2%) patients had two or more central venous catheter. BSI’s ratio was 7,7% (30 BSI /386 patients), with microbiologic confirmation in 14 patients which 86% of causal agent were gram-negative bacteria. The variable “duration of cardiopulmonary bypass” (P = 0,02) was independent associated with BSI, with a cut off equal or above 124 minutes, which was identified on ROC curve. BSI was more frequent in the highest severity group and in patients with open chest (P < 0,001). Mortality was 11% (43 deaths/386 patients) and “duration time of cardiopulmonary bypass” was significant associated with death (P = 0,001). Death incidence was higher in BSI patients (P = 0,005), but in the multivariate analysis it did not maintain statistical significance. Conclusions – Central venous catheter did not show independent association with BSI development. Although “cardiopulmonary bypass duration” could reflect the patient’s severity, it was strongly associated with BSI occurrence in this study, mainly after 124 minutes of duration. The BSI was not identified as independent risk factor for death in this population.
146

Modelagem e simulação da proteção diferencial de transformadores de potência no ATP

Tavares, Karla Antunes 06 December 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Engenharia Elétrica, Faculdade de Tecnologia, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-03-14T11:37:03Z No. of bitstreams: 1 2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-19T13:28:18Z (GMT) No. of bitstreams: 1 2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Made available in DSpace on 2014-03-19T13:28:18Z (GMT). No. of bitstreams: 1 2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Este trabalho tem por objetivo apresentar a modelagem e simulação de um relé numérico microprocessado para proteção de transformadores de potência. Foram implementadas as funções de proteção diferencial percentual de fase (87T), de sequência negativa (87Q) e de falta à terra restrita (REF). Para tanto, utiliza-se o software ATP, através de sua interface ATPDraw, sendo o relé implementado no ambiente MODELS. A validação do modelo foi feita para um sistema elétrico de potência simplificado, cujos parâmetros foram obtidos a partir de dados dos componentes de um sistema real. Os resultados mostram as vantagens da utilização desse tipo de modelagem, uma vez que ela permite a realização da chamada simulação em malha fechada, por meio da qual é possível avaliar o comportamento do sistema de potência frente à operação da sua proteção, bem como o da proteção frente as mais diversas situações de operação às quais um sistema de potência pode ser submetido. Além disso, também são observadas as vantagens de se utilizar de forma combinada as três funções de proteção implementadas. _______________________________________________________________________________________ ABSTRACT / This work aims to present the modeling and simulation of a numerical relay for protection of power transformers. It was implemented the phase percentage differential function (87T), negative sequence (87Q) and restricted earth fault (REF). In order to do so, the software ATP was used, through its interface ATPDraw, and the relay was implemented using the MODELS language. The model validation was carried out for a simplified electric power system, whose parameters were obtained from data of the components of a real system. The results reveal the advantages of using this type of modeling, since it provides a closed loop simulation, thereby one can evaluate the behavior of the power system against the protection operation, as well as the protection performance for the different power systems operational conditions. Moreover, one can see the advantages of using the three protection functions implemented together.
147

Propriedades elétricas da descarga corona obtida com geometrias do tipo ponta e plano / Electrical properties of corona discharge in point-to-plane geometry

Aldo Eloizo Job 27 June 1989 (has links)
Usando geometrias do tipo ponta e plano estudou-se as características elétricas da descarga corona positiva e negativa. Mediram-se as distribuições da densidade de corrente elétrica e do campo elétrico sobre o plano coletor dos íons. São discutidos os resultados obtidos para o sistema ponta planos e para o sistema em que o campo elétrico externo é aplicado através de uma placa adicional colocada perto da ponta. Neste último caso os resultados são interpretados com um modelo teórico que supõe que os íons se movem direção perpendicular entre as placas, sob a ação de um campo constante e lateralmente sob o campo de repulsão da carga espacial. / Electric characteristics of a positive and negative corona discharge were studied for geometries of the type point and plane. The electric current density and the electric field distributions on the collector plane were measured. We discuss the results obtained with the point and plane geometry and with the geometry were a external electric field is applied by means of an additional metallic plate fixed near the point. For the latter geometry the results were interpreted by using a theoretical model in which it is assumed that the ions drift in the direction perpendicular to the plates under a constant electric field and laterally under the field of the ionic space charge.
148

Uma câmara de ionização sólida / A solid ionization chamber

Marcilio de Freitas 13 June 1984 (has links)
Assumindo elétrons e buracos se movimentando em suas bandas próprias e centros de recombinação independente para ambos, Hughes e Sokel calcularam as características e distribuição de cargas para o oxido de chumbo (PbO) quando este se encontra sob radiação. O cálculo também inclui a corrente de difusão e segundo os autores, esta possui um importante papel em muitos aspectos. Neste trabalho a característica para o PbO foi recalculado sem considerar a contribuição da corrente de difusão e essencialmente foi obtido o mesmo resultado. Foram desenvolvidos aproximações para baixo e alto campo. Em seguida, foram assumidos iguais parâmetros para ambos portadores (isto é, iguais mobilidades, tempos de captura, coeficientes de recombinação e densidades de centros de captura) e obtido as características para 18 combinações de três conjuntos de parâmetros convenientemente definidos. Aproximações de campo baixo e campo alto foram também derivadas para este caso / Assuming electron and hole bands and independent recombination centers or both carriers, Hughes and Sokel calculated the characteristics and charge distributions for lead oxide PbO under irradiation. The calculation also included the diffusion current and it was asserted that such a current was important in some aspects. In this work the characteristic for PbO was recalculated without the diffusion component and essentially the same result was obtained. Side this; approximations were derived for low and high fields. Next, assuming equal parameters for both carriers (that is, equal mobilities, trapping times, recombination rates and density of trap), characteristics were obtained for 18 combinations of three conveniently defined set of parameters. Low and high field approximation were also derived for this case
149

Mecanismos biofísicos que afetam a resistência de entrada e a constante de tempo da membrana de neurônios: estudos experimentais e de simulação computacional / Biophysical mechanisms that affect the membrane input resistance and time constant of neurons: experimental and computational studies

Cesar Augusto Celis Ceballos 24 October 2017 (has links)
As correntes subliminares determinam propriedades da membrana neuronal, tais como a resistência de entrada (Rin) e a constante de tempo (tm). Nesta tese, estudamos mecanismos pelos quais duas correntes subliminares (corrente ativada por hiperpolarização, Ih, e corrente de sódio persistente, INaP) determinam Rin e tm em dois tipos de neurônio: neurônio fusiforme do núcleo coclear dorsal e célula piramidal da região CA1 do hipocampo. A tese está dividida em três partes: a primeira estuda como a Ih atua concomitantemente com a corrente de potássio retificadora de entrada (IKIR) para manter Rin estacionária entre neurônios fusiformes com heterogeneidade de disparo (silenciosos, sem disparos espontâneos, e ativos, com disparos espontâneos regulares). Na segunda parte, usa-se uma combinação de modelagem computacional com a técnica experimental de dynamic-clamp em neurônios piramidais de fatias hipocampais para mostrar que a criação de uma região de inclinação negativa na curva I/V (condutância de inclinação negativa) pela ativação rápida da INaP é responsável pelo aumento de Rin e tm e pela amplificação e prolongamento dos potenciais pós-sinápticos das células. Finalmente, a terceira parte estabelece o mecanismo pelo qual a INaP e Ih controlam a tm da célula. Para isso, propomos um novo conceito denominado \"condutância de inclinação dinâmica\" que leva em consideração a cinética das correntes e explica os efeitos observados das cinéticas de Ih e INaP sobre tm. Com base nos resultados, prevemos que uma Ih com cinética rápida atenua e encurta os potenciais pós-sinápticos excitatórios muito mais que uma Ih com cinética lenta. / Subthreshold currents determine the neuronal membrane properties, such as the input resistance (Rin) and the membrane time constant (tm). In this thesis, we studied the mechanisms by which two subthreshold currents (the hyperpolarization-activated current, Ih, and the persistent sodium current, INaP) determine Rin and tm in two types of neurons: the fusiform neuron of the dorsal cochlear nucleus and the pyramidal cell of the CA1 region of the hippocampus. The thesis is divided in three parts: the first part studies how Ih acts concomitantly with the inwardly rectifying potassium current (IKIR) to equalize Rin among fusiform neurons with firing heterogeneity (quiet, without spontaneous firing and active, with regular spontaneous firing). In the second part, we used a combination of computational modeling with the experimental technique dynamic-clamp in pyramidal cells of hippocampal slices to show that the creation of a negative slope region in the I/V curve (negative slope conductance) by the fast activation of the INaP is responsible for the increase of Rin and tm, and for the amplification and prolongation of postsynaptic potentials in these cells. Finally, the third part establishes the mechanism whereby INaP and Ih control tm in the cell. For this, we propose a new concept called \"dynamic slope conductance\", which takes into consideration the current kinetics and explains the observed effects of Ih and INaP kinetics on tm. Based on the results, we predict that an Ih current with fast kinetics attenuates and shortens excitatory postsynaptic potentials strongly than an Ih current with slower kinetics.
150

Medição de corrente - Classe 15 kV em sistemas industriais com uso de dispositivo eletro-óptico / not available

Hamilton Carlos Ramos Pinto 25 May 2001 (has links)
Foi desenvolvido um sistema eletro-óptico, para medir correntes elétricas em sistemas elétricos de distribuição, possuindo baixo custo, eficiência, versatilidade e segurança. Neste sistema, uma bobina magnética, colocada próximo à linha e conectada em série com um diodo ou uma lâmpada elétrica, gera um sinal ótico que é transmitido por fibra ótica a um fotodetector. Ali o sinal de luz é convertido para um sinal elétrico para ser processado em um microcomputador. Um programa computacional dedicado, também desenvolvido, determina as correntes e também fornece relatórios dos sinais obtidos por longos períodos de tempo. / To measure electric currents on power distribution system 15 kV with low costs, efficiency, versatility and security, a magnetic-optic system was developed. In this system, a magnetic coil close to line and connected in series with a diode ar an electric lamp supplies an optic signal that is transmitted by fiber optic to a photo-detector. There the light signal is converted to electric signal to be processed in a microcomputer. A dedicated software for data acquisition that also here was developed determines the currents and also aims at supplying reports on the currents over a long period of time.

Page generated in 0.0679 seconds