• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 22
  • 22
  • 14
  • 12
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo do aterramento dos pés de torres de linha de transmissão frente às descargas atmosféricas /

Berardo, Benício Luiz. January 2012 (has links)
Orientador: André Christóvão Pio Martins / Coorientador: André Nunes de Souza / Banca: Oscar Armando Maldonado Astorga / Banca: Pedro da Costa Junior / Resumo: Este trabalho mostra o estudo de uma linha de transmissão onde ocorreram desligamentos causados por descargas atmosféricas. Esse estudo foi feito a partir de informações de desligamentos de linhas de transmissão da concessionária e dados extraídos de um sistema de análise e monitoramento de descargas atmosféricas. Para esse trecho da linha de transmissão foram identificadas incidências de descargas atmosféricas que causaram desligamentos, bem como descargas que não causaram desligamentos. Baseados nestas informações foram efetuadas medições em campo de resistência de aterramento dos contrapesos e da resistividade do solo, onde foi possível constatar através dos resultados que algumas torres apresentaram valores que ultrapassaram os valores normatizados. O levantamento dessas informações é o principal foco deste estudo, que visa fornecer subsídios para a identificação de torres problemáticas. Uma proposta clássica utilizada para melhorar o desempenho desta linha de transmissão frente à incidência de descargas atmosféricas foi testada mas seu resultado não foi muito satisfatário / Abstract: This paper shows the study of a transmission line where outages occurred because of lightnings. The study was made from information that came from the power utility transmission line disconnection and data obtained from lightnings analyses and monitoring system. For this part of the transmission line it was identified incidence of lightning that caused outages, as well as incidences that did not cause outages. Based on this information, it was performed field measurements of ground resistance counterpoise and resistivity where is was possible to find, trough the results that some of the towers present numbers trepassed the normal values. Coming up with this information is this information is the main goal of this study that aims to offer to identify the towers that contains problems. A classical proposal used to improve the performance of this transmission line facing the incidence of lightnings was tested but the result wasn't very satisfactory / Mestre
22

O calculo do campo eletrico em 2D gerado por linhas de transmissão e o efeito em seres vivos

Pinho, Antonio Carlos January 1994 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico / Made available in DSpace on 2012-10-16T07:19:15Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T19:07:13Z : No. of bitstreams: 1 98176.pdf: 3656990 bytes, checksum: 5a1e65cda15472783e3abfadc1d8a1a8 (MD5) / O campo elétrico em um ponto no espaço é de intensidade e direção variável conforme altere o valor do potencial escalar da linha de transmissão, com alimentação senoidal. O valor eficaz do campo elétrico é de intensidade única ao longo do tempo e fornece o valor máximo. Para se calcular o valor possuem representação de número complexo, com uma parte real e outra imaginária. Apresenta-se o cálculo do campo elétrico eficaz em 2D gerado por linhas de transmissão através do comum método de simulação de cargas e do, não tão comum, método de elementos finitos utilizando o potencial escalar elétrico complexo e da densidade de corrente elétrica em casos 2D e axissimétricos utilizando o método de elementos físicos. Apresentação dos efeitos sobre seres vivos dos campos elétricos e magnéticos. Valores de campo elétrico calculados através dos dois métodos são comparados com valores medidos, comcluindo-se pela eficácia do método de elementos finitos utilizando o potencial escalar elétrico complexo. O cálculo da densidade de corrente elétrica é continuidade do cálculo do campo elétrico, facilmente obtido no método de elementos finitos. Com o cálculo da corrente em 2D, nota-se que pessoas mais sensíveis poderiam perceber diretamente a existência do campo elétrico pela intensidade de corrente induzida. Da revisão bibliográfica dos efeitos dos campos elétricos e magnéticos sobre seres humanos, evidencia-se a incerteza em relação às conseqüências dos mesmos, apesar de que em crianças ocorre leucemia.

Page generated in 0.0991 seconds