• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ligas do sistema Cu-Al-Zn-Nb, Cu-Al e Cu-Zn : estudos da corrosão quimica e de algumas propriedades fisicas

Correr Sobrinho, Lourenço, 1960- 13 July 2018 (has links)
Orientador: João Manuel Domingos de Almeida Rollo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-13T23:36:24Z (GMT). No. of bitstreams: 1 CorrerSobrinho_Lourenco_M.pdf: 4734512 bytes, checksum: 569f73a3e6dcab008c7d35d1b1176426 (MD5) Previous issue date: 1991 / Resumo: No presente estudo foi elaborada uma liga EXPERIMENTAL à base de Cu-Al-Zn-Nb, onde os elementos de maior ponto de fusão que compõem a liga EXPERIMENTAL, foram adicionados na forma de pó. Alguns ensaios foram realizados, como: análise química. Dureza Vickers, análise metalográfica, corrosão através da análise eletroquímica potenciocinética, contração de fundição, fluidez e tração. A análise química foi realizada por via úmida, enquanto o ensaio de Dureza Vickers numa máquina Vickers Limited, e a metalografia num aparelho NEOPHOT 21 (CARL ZEISS). Já os testes de corrosão foram realizados num aparelho tipo CORROSCRIPT - TUCUSSEL e a contração de fundição em um anel metálico similar ao utilizado por 'EARNSHAW POT.10'. Para o ensaio de fluidez, foram utilizadas telas de nylon similares, a usada por 'PRESSWOOD POT.36'. O ensaio de tração foi efetuado numa máquina de ensaio UNIVERSAL LOSENHAUSENWERK de acordo com a especificação n. 5 da 'A.D.A. POT.1'. Este estudo foi desenvolvido, comparando-se os resultados da liga EXPERIMENTAL com os obtidos de duas ligas comerciais à base de cobre DURACAST MS e GOLDENT LA. Para obtenção dos corpos de prova foi utilizada a técnica de fundição odontológica pelo método da cera perdida. As fundições foram executadas através de um maçarico gás-oxigênio numa centrifuga convencional. Os resultados da análise metalográfica revelaram que não houve a formação de solução sólida nas três ligas estudadas. A liga EXPERIMENTAL e DURACAST MS apresentaram uma resistência à corrosão superior à liga GOLDENT LA. Quanto à Dureza Vickers, a liga EXPERIMENTAL apresentou um valor maior em relação às outras duas ligas. O valor da contração de fundição da liga DURACAST MS foi superior e a liga EXPERIMENTAL apresentou valores de fluidez superiores em relação às duas ligas comerciais. Já para o ensaio de tração, a liga EXPERIMENTAL foi superior e a liga GOLDENT LA apresentou maior valor de alongamento em relação às outras duas ligas / Abstract: In the present study it was been developed an experimental alloy fo the Cu-Zn-Al-Nb base. Where the elements the most point of fusion, that compose the experimental alloy where odds in a power form. Some experiments were made, such as: metallographic analysis, corrosion by test eletrochemical potenciocinetic analysis, castability test, tensile test, casting of shrinkage, chemical analysis and Hardness Vickres. The chemical analysis has been made through moist medium, while the Hardness Vickers experiment has been made in a machine Vickers Limited and the metallographic analysis in a device called NEOPHOT 21 (CARL ZEISS). And the corrosion test has been realized in a device called Corroscript Tucussel and the casting of Shrinkage in a metal ring similar to the one used by 'EARNSHAW IND POT.10¿. For the castability test it was used nets of nylon similar to the one used by 'PRESSWOOD POT.36' and the tensile experiment was realized in a machine of the Universal test LOSENHAUSENNERK according to the expecification n. 5 of 'A. D. A. POT.1'. All this study was developed comparing the results of the experimental alloy with ones obtained with two comercial alloys to the base of copper DURACAST MS and GOLDENT LA. In order to obtain test samples, the routine dental casting tecnique, was used with lost wax method. The castings were executed through a gas/oxigen blowpipe in conventional centrifuge. The results from the metalographic analysis has revealed that there hasn't been formation of a solid solution in the three studied alloys. Lhe EXPERIMENTAL and de DURACAST MS alloys have presented a resistance to corrosion superior to the GOLDENT LA alloy. Concerning the Hardness Vickers, the EXPERIMENTAL alloy has presented a bigger value in relation to the other two alloys. The value of casting Shrinkage of the DURACAST MS alloy was superior and the EXPERIMENTAL alloy has presented superior values of castability in relation to the comercial alloys. And for the tensile test the EXPERIMENTAL alloy was superior and the GOLDENT LA alloy has presented a bigger alongation value in relation to the other two alloys / Mestrado / Materiais Dentarios / Mestre em Odontologia
2

Proteção contra a corrosão com revestimentos de zinco e aluminio depositados por aspersão termica

Freire, Celia Marina de Alvarenga, 1960- 18 September 1986 (has links)
Orientador : Ettore Bresciani Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T15:09:26Z (GMT). No. of bitstreams: 1 Freire_CeliaMarinadeAlvarenga_M.pdf: 4365520 bytes, checksum: 256da52cc9a8c05cfc9dae72d892648c (MD5) Previous issue date: 1986 / Resumo: Estudo do comportamento relativo à corrosão de revestimentos de zinco e alumínio aplicados por aspersão térmica, tendo como variáveis a natureza do substrato (liga alumínio-silício ou vidro) e a espessura do depósito num meio de cloreto (solução de cloreto de sódio 3%). Estudo do comportamento do par galvânico formado pelo substrato e revestimento com o intuito de definir o grau de proteção galvânica exercido pelo depósito / Abstract: The corrosion behaviour of thermal sprayed aluminium and zinc coatings on aluminium-silicon alloys and on glass has been studied. The parameters studied were the substrate nature and coating thickness in a chloride media (3% NaCl solution). The behaviour of galvanic couples substrate-coating has been studied to determine de level of galvanic protection / Mestrado / Mestre em Engenharia Mecânica
3

Resistência à corrosão eletroquímica da liga TI-6AL4V prototipada para aplicações biomédicas

Rocha, Thais Lenquist da [UNESP] 07 November 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-11-07Bitstream added on 2014-06-13T19:55:30Z : No. of bitstreams: 1 rocha_tl_me_ilha.pdf: 2209567 bytes, checksum: 0779f425359ed3738d8731ce2f0ae1f2 (MD5) / A metodologia de Sinterização Direta de Metais por Laser (DMLS) é uma das novas tecnologias de manufaturas aditivas, utilizada para fabricação de componentes de geometrias complexas. Dada à possibilidade de obtenção de peças com geometrias complexas, este método possui um grande potencial para a manufatura de implantes personalizados de reconstituição óssea. Dentre os materiais utilizados no processo, o titânio e suas ligas se destacam por possuírem uma combinação de elevada resistência mecânica, alta resistência à corrosão eletroquímica e resposta biológica favorável. Este trabalho visou apresentar um estudo da corrosão eletroquímica em implante de liga Ti-6Al-4V obtido por DMLS. Os ensaios de corrosão eletroquímica foram realizados em temperatura ambiente e na presença do oxigênio atmosférico. Os eletrólitos utilizados foram Soro Fisiológico, Ringer Lactato e Solução de Hanks que simulam os meios fisiológicos, bem como os três meios acrescidos de Peróxido de Hidrogênio até atingirem pH~5,02 e pH~4,33 que simulam respectivamente reações de inflamação e infecção. As curvas de polarização potenciodinâmicas das amostras foram obtidas com uma velocidade de varredura de 1 mV/s e o intervalo de potencial varrido de -1 V a + 1,2 V. A área ensaiada das amostras (eletrodo de trabalho) foi de 0,5 cm2. As correntes de corrosão foram calculadas no intercruzamento das curvas anódica e catódica linearizadas, na região do potencial de corrosão. Os parâmetros eletroquímicos de corrosão obtidos foram: o potencial de corrosão, a densidade de corrente e a resistência à polarização. A análise qualitativa dos ensaios de corrosão foram obtidas mediante Microscopia Eletrônica de Varredura (MEV) e Microscopia Óptica, onde foi possível evidenciar aumento dos poros identificados na superfície após os ensaios / The methodology Direct Metal Laser Sintering (DMLS) is a new additive manufacturing technology, used for the manufacture of components of complex geometries. Given the possibility of obtaining parts with complex geometries, this method has a great potential for the manufacture of customized implants for bone reconstruction. Among the materials used in the process, titanium and its alloys are distinguished by possessing a combination of high mechanical strength, high corrosion resistance and electrochemical favorable biological response. This work aims to present a study of electrochemical corrosion in implant alloy Ti-6Al-4V obtained by DMLS. The electrochemical corrosion tests were performed at room temperature and in the presence of atmospheric oxygen. The electrolytes used were saline solution, Ringer Lactato and Hank´s solution simulating the fluids physiological, and added hydrogen peroxide until reaching pH~5,02 and pH~4,33 respectively which simulate the reactions of inflammation and infection . The potentiodynamic polarization curves of the samples were with a scan speed employed 1 mV/s and the sweep potential range of -1 V to + 1.2 V. The area of the samples tested (working electrode) was 0.5 cm2. The corrosion currents were calculated intercrossing the anode and cathode of the linearized curve in the region of potential corrosion. The electrochemical parameters obtained were: the corrosion potential of corrosion current density and polarization resistance. Qualitative analysis of the corrosion tests were performed by scanning electron microscopy (SEM) and optical microscopy, where it was possible to demonstrate increased presence of pores before corrosion tests
4

Avaliação da influência do número da acidez naftênica e da temperatura no comportamento corrosivo em aço aisi 316 utilizando técnica de ruído eletroquímico

Hass, Fernanda January 2013 (has links)
Orientador: Prof. Dr. Haroldo de Araújo Ponte / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia e Ciência dos Materiais - PIPE. Defesa: Curitiba, 16/10/2013 / Inclui referências / Resumo: O controle da corrosão naftênica é um dos maiores desafios das refinarias que processam petróleos pesados. Seu monitoramento visa à avaliação da efetividade do programa de controle da corrosão e o estabelecimento de limites operacionais, além de fornecer alarmes de mudança do comportamento corrosivo, proporcionando informações para ajuste do programa. Muitos trabalhos têm sido desenvolvidos em busca de informações sobre os parâmetros operacionais críticos e de metodologias de monitoramento, porém poucos propiciam um controle "online" preditivo e pró-ativo do processo corrosivo. Frente à necessidade de tornar os métodos de controle "online" mais adequados a realidade industrial, este trabalho propõe a consolidação do uso do Ruído Eletroquímico (RE) como ferramenta de reavaliação de parâmetros de controle e de monitoramento da corrosão por ácidos naftênicos. Em laboratório, avaliou-se o comportamento do aço AISI 316 em solução de óleo mineral e ácidos naftênicos. As variáveis estudadas foram o número de acidez total (0,5 mg KOH/g, 1,5 mg KOH/g e 2,5 mg KOH/g) e a temperatura da solução (ambiente, 65 oC, 120 ºC e 200 ºC). Nestas condições, a técnica de RE demonstrou ser eficiente para o monitoramento da corrosão naftênica. Palavras-chave: Corrosão Naftênica, Ruído Eletroquímico / Abstract: The naphthenic corrosion control is a challenge in refineries that process heavy oils. Its monitoring aims the evaluation of the corrosion control program effectiveness and the establishment of operational limits. Moreover, it must provide the corrosion rate of process comportments in order to allow a corrosion mitigation planning. Many researches have been developed in search of both information about the critic operational parameters and methodologies of corrosion monitoring, but few works propitiate a predictive and proactive online control of the corrosive process. With the necessity to improve the online control methodologies to the industrial conditions, this research proposes to consolidate the Electrochemical Noise (EN) as a tool to evaluate the control parameters and naphthenic corrosion monitoring. In laboratory, AISI steel 316 comportment was evaluated in a mineral oil solution with naphthenic. It was studied the influence of total acid number (0,5 mg KOH/g, 1,5 mg KOH/g e 2,5 mg KOH/g) and the solution temperature (room, 65 oC, 120 ºC and 200 ºC) at the corrosion rate. For these conditions, the EN technique seems to be an efficient monitoring technique for naphthenic corrosion rate detection. Keywords: Naphthenic Corrosion, Electrochemical Noise.
5

Resistência à corrosão eletroquímica da liga TI-6AL4V prototipada para aplicações biomédicas /

Rocha, Thais Lenquist da. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Coorientador: Carlos Alberto Picone / Banca: Vicente Afonso Ventrella / Banca: Maria Aparecida Larosa / Resumo: A metodologia de Sinterização Direta de Metais por Laser (DMLS) é uma das novas tecnologias de manufaturas aditivas, utilizada para fabricação de componentes de geometrias complexas. Dada à possibilidade de obtenção de peças com geometrias complexas, este método possui um grande potencial para a manufatura de implantes personalizados de reconstituição óssea. Dentre os materiais utilizados no processo, o titânio e suas ligas se destacam por possuírem uma combinação de elevada resistência mecânica, alta resistência à corrosão eletroquímica e resposta biológica favorável. Este trabalho visou apresentar um estudo da corrosão eletroquímica em implante de liga Ti-6Al-4V obtido por DMLS. Os ensaios de corrosão eletroquímica foram realizados em temperatura ambiente e na presença do oxigênio atmosférico. Os eletrólitos utilizados foram Soro Fisiológico, Ringer Lactato e Solução de Hanks que simulam os meios fisiológicos, bem como os três meios acrescidos de Peróxido de Hidrogênio até atingirem pH~5,02 e pH~4,33 que simulam respectivamente reações de inflamação e infecção. As curvas de polarização potenciodinâmicas das amostras foram obtidas com uma velocidade de varredura de 1 mV/s e o intervalo de potencial varrido de -1 V a + 1,2 V. A área ensaiada das amostras (eletrodo de trabalho) foi de 0,5 cm2. As correntes de corrosão foram calculadas no intercruzamento das curvas anódica e catódica linearizadas, na região do potencial de corrosão. Os parâmetros eletroquímicos de corrosão obtidos foram: o potencial de corrosão, a densidade de corrente e a resistência à polarização. A análise qualitativa dos ensaios de corrosão foram obtidas mediante Microscopia Eletrônica de Varredura (MEV) e Microscopia Óptica, onde foi possível evidenciar aumento dos poros identificados na superfície após os ensaios / Abstract: The methodology Direct Metal Laser Sintering (DMLS) is a new additive manufacturing technology, used for the manufacture of components of complex geometries. Given the possibility of obtaining parts with complex geometries, this method has a great potential for the manufacture of customized implants for bone reconstruction. Among the materials used in the process, titanium and its alloys are distinguished by possessing a combination of high mechanical strength, high corrosion resistance and electrochemical favorable biological response. This work aims to present a study of electrochemical corrosion in implant alloy Ti-6Al-4V obtained by DMLS. The electrochemical corrosion tests were performed at room temperature and in the presence of atmospheric oxygen. The electrolytes used were saline solution, Ringer Lactato and Hank's solution simulating the fluids physiological, and added hydrogen peroxide until reaching pH~5,02 and pH~4,33 respectively which simulate the reactions of inflammation and infection . The potentiodynamic polarization curves of the samples were with a scan speed employed 1 mV/s and the sweep potential range of -1 V to + 1.2 V. The area of the samples tested (working electrode) was 0.5 cm2. The corrosion currents were calculated intercrossing the anode and cathode of the linearized curve in the region of potential corrosion. The electrochemical parameters obtained were: the corrosion potential of corrosion current density and polarization resistance. Qualitative analysis of the corrosion tests were performed by scanning electron microscopy (SEM) and optical microscopy, where it was possible to demonstrate increased presence of pores before corrosion tests / Mestre
6

Avaliação do desempenho de latas de folha-de-flandres por meio da espectroscopia de impedancia eletroquimica e do acompanhamento da estocagem de palmito pupunha (Bactris gasipaes) enlatado

Faria, Eliete Vaz de 28 February 2000 (has links)
Orientadores: Celia Marina de Alvarenga Freire, Emilia Emico Miya Mori / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-26T15:26:35Z (GMT). No. of bitstreams: 1 Faria_ElieteVazde_D.pdf: 18961179 bytes, checksum: d0a3af80fe390686b1f2a79c961716b2 (MD5) Previous issue date: 2000 / Resumo: O desempenho de latas de folha-de-flandres com diferentes especificações no acondicionamento de palmito pupunha (Bactris gasipaes) foi avaliado por meio da aplicação da técnica de espectroscopia de impedância eletroquímica (EIS) e do acompanhamento da estocagem a 35°C e à temperatura ambiente do produto enlatado. Parâmetros físicos, metais dissolvidos no produto, aspecto visual interno das embalagens e a qualidade sensorial do produto foram monitorados durante a estocagem, buscando-se correlacionar o teor de ferro que se incorpora ao produto como conseqüência dos processos corrosivos que se estabelecem, com a percepção do sabor metálico no produto. Os resultados obtidos permitiram concluir que a EIS é capaz de prever diferenças no desempenho de diferentes especificações de materiais de embalagem no que diz respeito ao teor de metais que se dissolvem e niveis de corrosão que se estabelecem, identificando diferenças nos mecanismos de corrosão que se desenvolvem durante a estocagem. A concentração de ferro no palmito pupunha que causa reconhecimento do sabor metálico foi definida na faixa de 37 mglkg a 73 mglkg. Foram obtidas boas correlações entre a qualidade sensorial do produto e o teor de ferro para a estocagem a 35°C, mas não à temperatura ambiente. Nesta condição, o aspecto visual da embalagem torna-se o fator limitante da vida útil do produto / Abstract: The performance of different tinplate cans for pupunha hearts of palm (Bactris gasipaes) was evaluated by means of electrochemica1 impedance spectroscopy (EIS) and storage tests of the canned product at 3SoC and at room temperature. The storage was monitored concerning physica1 parameters, dissolved metais into the product, internal can corrosion examinations and sensory evaluation of the product, aiming to correlate the iron concentration into the product with the perception of metallic taste. From the obtained results one can conclude that the EIS could inform in advance the different performance of the cans with different material specifications relating to the corrosion level and corrosion mechanisms. The iron concentration in the product that causes a recognition of a metallic taste was defined in the range of 37 mg!kg to 73 mg!kg. Good correlation was found between sensory quality and iron concentration for the storage at 3 SOC, but not at room temperature, for which the visual appearance resulted ITom corrosion process become the critica1 factor / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
7

Analise da resistencia a corrosão do aço carbono revestido com Al55-Zn apos deformação mecanica e tratamento termico / Analysis of the corrosion resistance of the 55AI-Zn coating on carbon steel after mechanical deformation and heat treatment

Beserra, Antonio Adelmo Freire 01 December 2001 (has links)
Orientador: Celia Marina de A. Freire / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-29T00:11:40Z (GMT). No. of bitstreams: 1 Beserra_AntonioAdelmoFreire_D.pdf: 6476925 bytes, checksum: 51577bdfab4d41fd0bb2c35bf250bfc2 (MD5) Previous issue date: 2001 / Resumo: O revestimento de Al55-Zn apresenta uma resistência à corrosão atmosférica em média doze vezes superior à do revestimento galvanizado. Entretanto, após deformação mecânica, o revestimento de Al55-Zn apresenta microtrincas que comprometem a sua resistência à corrosão. Neste trabalho estudou-se a variação na resistência à corrosão do revestimento de Al55-Zn após deformação sob tração ou dobramento e a influência de tratamentos térmicos a '200 GRAUS' e a '360 GRAUS' durante 16h na resistência à corrosão do revestimento antes e depois das deformações. Para isso, um grupo de amostras do material foi deformado sob tensão de tração até 10% ou 15% de seu comprimento inicial e outro grupo foi dobrado até '90 GRAUS' ou '180 GRAUS'. A variação na resistência à corrosão do revestimento foi analisada através das técnicas de extrapolação de Tafel e de espectroscopia de impedância eletroquímica. Como resultado, observou-se que tanto a deformação axial quanto o dobramento do material reduzem a sua resistência à corrosão. Após o tratamento térmico a '360 GRAUS' as amostras deformadas até 10% ou 15% recuperaram a sua resistência à corrosão, entretanto, as amostras dobradas até '90 GRAUS' ou '180 GRAUS' apresentaram apenas uma recuperação parcial na sua resistência à corrosão após os tratamentos térmicos / Abstract: The atmospheric corrosion resistance of 55%Al-Zn alloy coating on average is twelve times that of an equal thickness of galvanized coating. However, it has been shown that microcracks were observed at all levels of strain under simple uniaxial tension. Our research has been focused on determining the degree of corrosion experienced by these coatings after deformation under simple tension or bending and how much the heat treatment at '200 DEGREES' or '360 DEGREES' for 16h can influence the corrosion resistance of the coating. The coated sheet samples were strained to 10% or 15% engineering strain while another group of samples was bent to bend angles of '90 DEGREES' or '180 DEGREES'. The corrosion resistance of the samples was evaluated trhough Tafel extrapolation and electrochemical impedance spectroscopy methods. As a result, it was observed that both the straining and the bending of the coating reduces its corrosion resistance. After the heat treatment at '360 DEGREES' the samples strained to 10% or 15% recover their corrosion resistance, but the specimens bended to '90 DEGREES' or '180 DEGREES' recuperate only partially the corrosion resistance after the heat treatments / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
8

Análise comparativa da resistência à corrosão eletroquímica da liga de Ti-6Al-4V e do aço inoxidável AISI316L obtidas por manufatura aditiva visando aplicações biomédicas /

Jaime, Gustavo Carneiro January 2017 (has links)
Orientador: Ruis Camargo Tokimatsu / Resumo: A procura por materiais, com compatibilidade e funcionalidade biológicas, que possam melhorar a qualidade da vida humana é constante, além da busca de processos de fabricação que atendam às necessidades de manufatura de artefatos de geometria complexa. Os artefatos de aço inoxidável são utilizados por possuírem uma boa biocompatibilidade, baixo custo de produção, mas podem liberar íons como o cobalto, que é carcinogênico. O uso de Ligas de titânio é uma boa alternativa, já que possuem uma maior resistência à corrosão e boa resposta biológica, porém, seu custo é muito elevado. Considerando esses aspectos, o presente trabalho foi realizado buscando estudar, comparativamente, as características de microdureza, microdesgaste e resistência à corrosão de artefatos manufaturados para aplicações biomédicas, aproveitando as características mecânicas da liga de aço inoxidável AISI316L, usado como substrato, com as características eletroquímicas apresentadas pela liga de titânio Ti-6Al-4V, usado como material de tratamento de superfície. A sinterização direta dos metais por laser (DMLS) foi o processo de manufatura escolhido por apresentar as características de fabricação desejadas. Os ensaios realizados foram o de microdureza Vickers, ensaio de desgaste microadesivo por esfera rotativa fixa (esfera-fixa) e para o comparativo da resistência à corrosão eletroquímica foram produzidas curvas de polarização potenciodinâmicas que forneceram os seguintes parâmetros: o potencial de corrosão, a... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.3078 seconds