• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Programa de cribaje de la retinopatía diabética en el Vallès Oriental mediante cámara no midriática. Estudio de 5228 pacientes diabéticos tipo 2

Hernecki, Jaroslaw 03 February 2010 (has links)
La presente tesis doctoral recoge los resultados del programa de cribaje de la retinopatía diabética mediante la cámara no midriática en la comarca de Vallès Oriental (Barcelona). Es un estudio de 5228 pacientes diabéticos tipo 2 no cribados previamente.Se analizan las características demográficas del grupo estudiado, los datos de la diabetes (el tipo de tratamiento, tiempo de evolución de la diabetes y el control metabólico) y la prevalencia de la retinopatía diabética. Se calcula la sensibilidad, la especificidad, el valor predictivo positivo y negativo del método en comparación con la exploración biomicroscópica en la lámpara de hendidura. Posteriormente, se estudia el grupo de pacientes con imágenes no valorables, se determinan las causas del fallo técnico en cada caso y se calcula la prevalencia de la retinopatía diabética en este grupo. Se analiza si existen diferencias significativas entre este grupo y los pacientes con imágenes de buena calidad. Mediante un análisis uni- y multivariante se valoran posibles factores de riesgo para presentar la retinopatía diabética. Posteriormente, se calcula la concordancia del diagnóstico de la cámara no midriática con el clínico y el angiográfico para la retinopatía derivable (moderada o superior). Se realiza una auditoría externa de los resultados del programa como medida de control de calidad del mismo. Se calcula la concordancia de los diagnósticos de dos optometristas entrenados para el cribaje de la retinopatía diabética con el del especialista de retina y, finalmente, se estudia el impacto del programa en el funcionamiento de las consultas externas.Se estudian 5228 pacientes diabéticos tipo 2. La prevalencia de la retinopatía diabética en la población analizada se sitúa en 11,9%. Se detectan diferencias significativas en la prevalencia de la retinopatía diabética en diferentes grupos de tratamiento, control metabólico y tiempo de duración de la diabetes. La sensibilidad de la cámara no midriática es del 93,8% y la especificidad del 98,9%. La causa más frecuente de la calidad insuficiente de la imagen es la miosis refractaria a la oscuridad, seguida de catarata. La prevalencia de la retinopatía diabética en los pacientes con miosis es significativamente más alta que en los pacientes con imágenes de buena calidad, con más pacientes con estadios graves de la retinopatía. Los factores de riesgo para presentar la retinopatía diabética son el tipo de tratamiento, el tiempo de evolución de la diabetes, el control metabólico y la calidad insuficiente de la imagen por la miosis. El diagnóstico de la cámara no midriática presenta una alta concordancia con el biomicroscópico; sin embargo, cuando se compara con la angiografía, la concordancia es más baja. Se encuentra muy poca variabilidad inter-observador del método. Demostramos la posibilidad de implicar a los optometristas en la tarea del cribaje- existe una elevada concordancia entre sus diagnósticos y los de un especialista de retina. La utilización de la cámara no midriática comporta un aumento de trabajo de los técnicos y disminución del tiempo dedicado por los oftalmólogos. / This thesis contains the results of a diabetic retinopathy screening programme using a nonmydriatic digital camera in Vallès Oriental county (Barcelona, Spain). It is a study of 5228 type 2 previously unscreened diabetic patients.The demographic characteristics of the studied population, diabetes data (type of treatment, diabetes duration and metabolic control) and prevalence of diabetic retinopathy are analysed. Sensitivity, specificity, positive and negative predictive values of the method are calculated as compared with slit-lamp examination. The patients with poor quality images are studied, the cause of poor image quality is determined in each case and diabetic retinopathy prevalence in this group is calculated. Differences between poor quality image group and the patients with gradable images are established. Univariate and multivariate analysis is carried out to study association between diabetic retinopathy and putative risk factors. Concordance between nonmydriatic camera and clinical and angiographic diagnoses is studied for referable retinopathy levels (moderate or superior). External audit of the programme results is carried out as a quality control measure. Concordance between two optometrists' and a retina specialist's diagnoses is calculated. Finally, the screening programme impact on the Outpatients' Department is established.5228 type 2 diabetic patients are studied. Diabetic retinopathy prevalence in the analysed population is 11,9%. There are significant differences in diabetic retinopathy prevalence between different groups of treatment, diabetes duration, and metabolic control. Nonmydriatic camera sensitivity is 93,8% and specificity 98,9%, as compared with dilated fundoscopy at a slit-lamp. The most frequent cause of poor quality image is myosis followed by cataract. Diabetic retinopathy prevalence in patients with myosis is significantly higher than in patients with gradable images, with more patients suffering from grave and proliferative retinopathy. In uni- and multivariate analyses, factors associated with diabetic retinopathy include type of treatment, disease duration, glycosylated haemoglobin level, and poor image quality due to myosis. There is a high concordance between nonmydriatic camera and dilated fundoscopy diagnoses. However, when compared with angiography, the concordance is lower. A very low inter-observer variability of the method is found. We demonstrate the possibility of implicating optometrists in diabetic retinopathy screening- there is an elevated concordance between optometrists' and a retinal specialist's diagnoses. The use of a nonmydriatic digital camera in diabetic retinopathy screening results in an increase of optometrists' workload and less time dedicated by ophthalmologists.
2

Validación de la versión española de la SOMS-2 (Screening for Somatoform Symptoms-2) para la evaluación de síntomas somáticos en Atención Primaria

Bauzá Siddons, Natalia 31 October 2012 (has links)
Objetivo: Analizar propiedades psicométricas de la versión española del Screening for Somatoform Symptoms (SOMS-2) en muestra de pacientes de Atención Primaria de España. Método: Se administró la traducción Española de la versión original de la SOMS-2 junto con la Entrevista Psiquiátrica Estructurada Polivalente (EPEP) a una muestra 165 pacientes de Atención Primaria. 74 pacientes realizaron un tratamiento cognitivo-conductual de 10 sesiones semanales de hora y media de duración. Se evaluó la fiabilidad test-retest a 6 y 12 meses de finalizar el tratamiento. Resultados: La SOMS-2 de 53 ítems y con punto de corte de 4 presenta sensibilidad del 97%, especificidad de 68%, Valor Predictivo Positivo (VPP) de 85% y Valor Predictivo Negativo (VPN) de 92% y α de Cronbach de 0,82. Conclusiones: La versión española de la SOMS-2 muestra buena consistencia interna, sensibilidad y especificidad. Resulta un instrumento de cribaje útil para evaluar el trastorno de somatización en Atención Primaria.

Page generated in 0.0324 seconds