• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 1
  • Tagged with
  • 35
  • 35
  • 17
  • 17
  • 15
  • 12
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido / Dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) subject to varying hydraulic load rate on the treatment of domestic sewage

Godinho, Jayson Pereira 13 February 2017 (has links)
CAPES / O processo de digestão anaeróbia é muito importante no tratamento dos esgotos sanitários, por ser eficiente, simples e de baixo custo de implantação, operação e manutenção. Embora o Brasil tenha à disposição processos anaeróbios consolidados, o saneamento básico ainda é deficiente no país, e a otimização de reatores anaeróbios tem o intuito de melhorar a viabilidade, efetividade e ampliação dos sistemas de tratamento dos esgotos sanitários. O objetivo deste projeto foi avaliar o desempenho através do comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido (UAHB), com variação do tempo de detenção hidráulica (TDH) de 4 a 12 h e da DQO (amostras brutas) de 250 a 1250 mgO2L-1. O reator, com volume útil de 22,1 L, foi operado com meio suporte de anéis corrugados de Policloreto de Polivinila (PVC) e mantido a temperatura ambiente, sendo o afluente de alimentação, sintético simulando o esgoto sanitário. Foram analisados os parâmetros físico-químicos: temperatura do líquido e do ar, pH, alcalinidade total (AT), alcalinidade a bicarbonato (AB), ácidos voláteis (AV), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO520), Turbidez, Sólidos Totais (ST), Sólidos Suspensos Totais (SST), nitrogênio total kjeldahl (N-NTK), nitrogênio amoniacal (Namon), nitrito(N-NO2-), nitrato (N-NO3-) e fósforo total (P). Foi avaliado o comportamento hidrodinâmico e verificada a existência de anomalias hidráulicas, pela técnica de estímulo-resposta tipo pulso com injeção do traçador eosina Y. Ao final dos experimentos, foi realizada a análise estatística para encontrar a condição operacional ótima, bem como os modelos estatísticos para validação dos experimentos. Em todas as condições operacionais foi possível observar que o reator UAHB entrou em equilíbrio dinâmico aparente (EEDA) com produção de alcalinidade para neutralizar os ácidos voláteis produzidos no processo de acidogênese e acetogênese da digestão anaeróbia. O aumento da carga orgânica volumétrica acarretou no aumento das eficiências de remoção em DQO (amostras brutas e filtradas), DBO520 e Turbidez, mas reduziu as remoções de Sólidos Totais e Sólidos Suspensos Totais. A diminuição do TDH reduziu as eficiências de remoção dos parâmetros DQO (amostras brutas e filtradas), DBO520, Sólidos Totais, Sólidos Suspensos Totais e Turbidez. Em relação à hidrodinâmica, em todas as condições operacionais foi observado o efeito de cauda longa, o regime de escoamento no interior do reator UAHB foi classificado como de tanques de mistura completa em série (NCSTR). Foi verificada a presença de zonas mortas no reator, a eficiência hidráulica foi em média 65% para as três condições e não foi possível observar a presença de curtos-circuitos para os três TDH testados. Pela análise estatística do delineamento composto central rotativo (DCCR), a condição ótima de operação para o reator foi para o TDH 12 h e DQO (amostras brutas) 553 mgO2.L-1. / The anaerobic digestion process is very important in the treatment of sewage, as it is an efficient, simple process and low cost of implementation, operation and maintenance. Although Brazil has provided consolidated anaerobic processes, sanitation is still poor in the country, and the optimization of anaerobic reactors aims to improve the viability, effectiveness and expansion of treatment systems for sewage. The aim of this research project is to evaluate the reactor's performance through dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) with a range of hydraulic retention time (HRT) of 4 to 12 hours and COD (gross samples) 250 - 1250 mgO2L -1. The reactor, with a volume of 22.1 L was operated with support means corrugated rings of Polyvinyl chloride (PVC) and kept at room temperature, the influent feed, simulating the synthetic wastewater. the physicochemical parameters were analyzed: temperature of the liquid and air, pH, total alkalinity (TA), bicarbonate alkalinity (BA), volatile acids (VA), chemical oxygen demand (COD), biochemical oxygen demand (BOD ), Turbidity, Total Solids (TS), total suspended solids (TSS), nitrogen Total Kjeldahl (NTK-N), ammonia nitrogen (amon-N), nitrite (NO2-N), nitrate (NO3-N) and Total phosphorus (P). It evaluated the hydrodynamic behavior and the determination of hydraulic anomalies, the stimulus-response pulse technique with injection of the tracer eosin Y. At the end of the experiments, statistical analysis was performed to find the optimal operating condition as well as the statistical models for validation experiments. In all operating conditions it was observed that the UAHB Reactor became apparent dynamic equilibrium (ADE) with alkalinity production to neutralize the volatile acids produced in acetogenesis process of anaerobic digestion. The increased of organic loading rate resulted in increased efficiencies in the removal of COD (gross and filtered samples), BOD and Turbidity, but reduced removals of Total Solids and Total Suspended Solids. The decrease in HRT reduced the removal efficiencies of COD parameters (grosss and filtered samples), BOD, Total Solids, Total Suspended Solids and Turbidity. Regarding the hydrodynamic in all operating conditions was observed long tail effect, the flow regime inside the reactor UAHB was rated as complete mixing tanks in series (N-CSTR). The presence of dead zones in the reactor was checked, the hydraulic efficiency was averaged 65% for the three conditions and it was not possible to observe the presence of short circuits for the three HRT tested. For the statistical analysis of the central rotary compound design (CRCD), the optimum operating condition for the reactor was to HRT 12 h and COD (gross samples) 553 mgCOD.L-1.
32

Comportamento dinâmico e hidrodinâmico de um reator anaeróbico híbrido (UAHB) submetido à variação de carga hidráulica horária no tratamento de esgoto sanitário / Dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) subject to varying hydraulic load rate on the treatment of domestic sewage

Godinho, Jayson Pereira 13 February 2017 (has links)
CAPES / O processo de digestão anaeróbia é muito importante no tratamento dos esgotos sanitários, por ser eficiente, simples e de baixo custo de implantação, operação e manutenção. Embora o Brasil tenha à disposição processos anaeróbios consolidados, o saneamento básico ainda é deficiente no país, e a otimização de reatores anaeróbios tem o intuito de melhorar a viabilidade, efetividade e ampliação dos sistemas de tratamento dos esgotos sanitários. O objetivo deste projeto foi avaliar o desempenho através do comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido (UAHB), com variação do tempo de detenção hidráulica (TDH) de 4 a 12 h e da DQO (amostras brutas) de 250 a 1250 mgO2L-1. O reator, com volume útil de 22,1 L, foi operado com meio suporte de anéis corrugados de Policloreto de Polivinila (PVC) e mantido a temperatura ambiente, sendo o afluente de alimentação, sintético simulando o esgoto sanitário. Foram analisados os parâmetros físico-químicos: temperatura do líquido e do ar, pH, alcalinidade total (AT), alcalinidade a bicarbonato (AB), ácidos voláteis (AV), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO520), Turbidez, Sólidos Totais (ST), Sólidos Suspensos Totais (SST), nitrogênio total kjeldahl (N-NTK), nitrogênio amoniacal (Namon), nitrito(N-NO2-), nitrato (N-NO3-) e fósforo total (P). Foi avaliado o comportamento hidrodinâmico e verificada a existência de anomalias hidráulicas, pela técnica de estímulo-resposta tipo pulso com injeção do traçador eosina Y. Ao final dos experimentos, foi realizada a análise estatística para encontrar a condição operacional ótima, bem como os modelos estatísticos para validação dos experimentos. Em todas as condições operacionais foi possível observar que o reator UAHB entrou em equilíbrio dinâmico aparente (EEDA) com produção de alcalinidade para neutralizar os ácidos voláteis produzidos no processo de acidogênese e acetogênese da digestão anaeróbia. O aumento da carga orgânica volumétrica acarretou no aumento das eficiências de remoção em DQO (amostras brutas e filtradas), DBO520 e Turbidez, mas reduziu as remoções de Sólidos Totais e Sólidos Suspensos Totais. A diminuição do TDH reduziu as eficiências de remoção dos parâmetros DQO (amostras brutas e filtradas), DBO520, Sólidos Totais, Sólidos Suspensos Totais e Turbidez. Em relação à hidrodinâmica, em todas as condições operacionais foi observado o efeito de cauda longa, o regime de escoamento no interior do reator UAHB foi classificado como de tanques de mistura completa em série (NCSTR). Foi verificada a presença de zonas mortas no reator, a eficiência hidráulica foi em média 65% para as três condições e não foi possível observar a presença de curtos-circuitos para os três TDH testados. Pela análise estatística do delineamento composto central rotativo (DCCR), a condição ótima de operação para o reator foi para o TDH 12 h e DQO (amostras brutas) 553 mgO2.L-1. / The anaerobic digestion process is very important in the treatment of sewage, as it is an efficient, simple process and low cost of implementation, operation and maintenance. Although Brazil has provided consolidated anaerobic processes, sanitation is still poor in the country, and the optimization of anaerobic reactors aims to improve the viability, effectiveness and expansion of treatment systems for sewage. The aim of this research project is to evaluate the reactor's performance through dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) with a range of hydraulic retention time (HRT) of 4 to 12 hours and COD (gross samples) 250 - 1250 mgO2L -1. The reactor, with a volume of 22.1 L was operated with support means corrugated rings of Polyvinyl chloride (PVC) and kept at room temperature, the influent feed, simulating the synthetic wastewater. the physicochemical parameters were analyzed: temperature of the liquid and air, pH, total alkalinity (TA), bicarbonate alkalinity (BA), volatile acids (VA), chemical oxygen demand (COD), biochemical oxygen demand (BOD ), Turbidity, Total Solids (TS), total suspended solids (TSS), nitrogen Total Kjeldahl (NTK-N), ammonia nitrogen (amon-N), nitrite (NO2-N), nitrate (NO3-N) and Total phosphorus (P). It evaluated the hydrodynamic behavior and the determination of hydraulic anomalies, the stimulus-response pulse technique with injection of the tracer eosin Y. At the end of the experiments, statistical analysis was performed to find the optimal operating condition as well as the statistical models for validation experiments. In all operating conditions it was observed that the UAHB Reactor became apparent dynamic equilibrium (ADE) with alkalinity production to neutralize the volatile acids produced in acetogenesis process of anaerobic digestion. The increased of organic loading rate resulted in increased efficiencies in the removal of COD (gross and filtered samples), BOD and Turbidity, but reduced removals of Total Solids and Total Suspended Solids. The decrease in HRT reduced the removal efficiencies of COD parameters (grosss and filtered samples), BOD, Total Solids, Total Suspended Solids and Turbidity. Regarding the hydrodynamic in all operating conditions was observed long tail effect, the flow regime inside the reactor UAHB was rated as complete mixing tanks in series (N-CSTR). The presence of dead zones in the reactor was checked, the hydraulic efficiency was averaged 65% for the three conditions and it was not possible to observe the presence of short circuits for the three HRT tested. For the statistical analysis of the central rotary compound design (CRCD), the optimum operating condition for the reactor was to HRT 12 h and COD (gross samples) 553 mgCOD.L-1.
33

Comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido / Dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) subject to varying hydraulic load rate on the treatment of domestic sewage

Godinho, Jayson Pereira 13 February 2017 (has links)
CAPES / O processo de digestão anaeróbia é muito importante no tratamento dos esgotos sanitários, por ser eficiente, simples e de baixo custo de implantação, operação e manutenção. Embora o Brasil tenha à disposição processos anaeróbios consolidados, o saneamento básico ainda é deficiente no país, e a otimização de reatores anaeróbios tem o intuito de melhorar a viabilidade, efetividade e ampliação dos sistemas de tratamento dos esgotos sanitários. O objetivo deste projeto foi avaliar o desempenho através do comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido (UAHB), com variação do tempo de detenção hidráulica (TDH) de 4 a 12 h e da DQO (amostras brutas) de 250 a 1250 mgO2L-1. O reator, com volume útil de 22,1 L, foi operado com meio suporte de anéis corrugados de Policloreto de Polivinila (PVC) e mantido a temperatura ambiente, sendo o afluente de alimentação, sintético simulando o esgoto sanitário. Foram analisados os parâmetros físico-químicos: temperatura do líquido e do ar, pH, alcalinidade total (AT), alcalinidade a bicarbonato (AB), ácidos voláteis (AV), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO520), Turbidez, Sólidos Totais (ST), Sólidos Suspensos Totais (SST), nitrogênio total kjeldahl (N-NTK), nitrogênio amoniacal (Namon), nitrito(N-NO2-), nitrato (N-NO3-) e fósforo total (P). Foi avaliado o comportamento hidrodinâmico e verificada a existência de anomalias hidráulicas, pela técnica de estímulo-resposta tipo pulso com injeção do traçador eosina Y. Ao final dos experimentos, foi realizada a análise estatística para encontrar a condição operacional ótima, bem como os modelos estatísticos para validação dos experimentos. Em todas as condições operacionais foi possível observar que o reator UAHB entrou em equilíbrio dinâmico aparente (EEDA) com produção de alcalinidade para neutralizar os ácidos voláteis produzidos no processo de acidogênese e acetogênese da digestão anaeróbia. O aumento da carga orgânica volumétrica acarretou no aumento das eficiências de remoção em DQO (amostras brutas e filtradas), DBO520 e Turbidez, mas reduziu as remoções de Sólidos Totais e Sólidos Suspensos Totais. A diminuição do TDH reduziu as eficiências de remoção dos parâmetros DQO (amostras brutas e filtradas), DBO520, Sólidos Totais, Sólidos Suspensos Totais e Turbidez. Em relação à hidrodinâmica, em todas as condições operacionais foi observado o efeito de cauda longa, o regime de escoamento no interior do reator UAHB foi classificado como de tanques de mistura completa em série (NCSTR). Foi verificada a presença de zonas mortas no reator, a eficiência hidráulica foi em média 65% para as três condições e não foi possível observar a presença de curtos-circuitos para os três TDH testados. Pela análise estatística do delineamento composto central rotativo (DCCR), a condição ótima de operação para o reator foi para o TDH 12 h e DQO (amostras brutas) 553 mgO2.L-1. / The anaerobic digestion process is very important in the treatment of sewage, as it is an efficient, simple process and low cost of implementation, operation and maintenance. Although Brazil has provided consolidated anaerobic processes, sanitation is still poor in the country, and the optimization of anaerobic reactors aims to improve the viability, effectiveness and expansion of treatment systems for sewage. The aim of this research project is to evaluate the reactor's performance through dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) with a range of hydraulic retention time (HRT) of 4 to 12 hours and COD (gross samples) 250 - 1250 mgO2L -1. The reactor, with a volume of 22.1 L was operated with support means corrugated rings of Polyvinyl chloride (PVC) and kept at room temperature, the influent feed, simulating the synthetic wastewater. the physicochemical parameters were analyzed: temperature of the liquid and air, pH, total alkalinity (TA), bicarbonate alkalinity (BA), volatile acids (VA), chemical oxygen demand (COD), biochemical oxygen demand (BOD ), Turbidity, Total Solids (TS), total suspended solids (TSS), nitrogen Total Kjeldahl (NTK-N), ammonia nitrogen (amon-N), nitrite (NO2-N), nitrate (NO3-N) and Total phosphorus (P). It evaluated the hydrodynamic behavior and the determination of hydraulic anomalies, the stimulus-response pulse technique with injection of the tracer eosin Y. At the end of the experiments, statistical analysis was performed to find the optimal operating condition as well as the statistical models for validation experiments. In all operating conditions it was observed that the UAHB Reactor became apparent dynamic equilibrium (ADE) with alkalinity production to neutralize the volatile acids produced in acetogenesis process of anaerobic digestion. The increased of organic loading rate resulted in increased efficiencies in the removal of COD (gross and filtered samples), BOD and Turbidity, but reduced removals of Total Solids and Total Suspended Solids. The decrease in HRT reduced the removal efficiencies of COD parameters (grosss and filtered samples), BOD, Total Solids, Total Suspended Solids and Turbidity. Regarding the hydrodynamic in all operating conditions was observed long tail effect, the flow regime inside the reactor UAHB was rated as complete mixing tanks in series (N-CSTR). The presence of dead zones in the reactor was checked, the hydraulic efficiency was averaged 65% for the three conditions and it was not possible to observe the presence of short circuits for the three HRT tested. For the statistical analysis of the central rotary compound design (CRCD), the optimum operating condition for the reactor was to HRT 12 h and COD (gross samples) 553 mgCOD.L-1.
34

Proposi??o de um modelo para an?lise de fluxo de carga, curto-circuito e simula??o de rel?s de produ??o

Oliveira, Arrhenius Vin?cius da Costa 17 December 2004 (has links)
Made available in DSpace on 2014-12-17T14:55:18Z (GMT). No. of bitstreams: 1 ArrheniusVCO_da_capa_ate_pag_12.pdf: 7828798 bytes, checksum: b0f0c76e1aebc32a2155c024e0abc8a9 (MD5) Previous issue date: 2004-12-17 / The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used / O presente trabalho objetiva ao desenvolvimento de um modelo para simular redes de energia el?trica em regimes transit?rio e permanente, utilizando o software ATP (Alternative Transient Program), para servir como elo entre dois temas distintos, presentes na metodologia cl?ssica de planejamento de redes: a an?lise de curtos-circuitos e o estudo de fluxo de carga. Al?m disso, dispondo de uma ferramenta de simula??o de rel?s, pretende-se usar o novo modelo, tanto para averiguar a influ?ncia de fen?menos transit?rios na opera??o dos rel?s de prote??o, quanto para calibrar esses rel?s. Para testar o modelo, utilizaram-se alguns dos rel?s atualmente instalados na COSERN
35

Seleção e alocação de dispositivos limitadores de corrente de curto-circuito utilizando o algoritmo evolucionário multiobjetivo NSGA-II

Brito, Felix Estevam de Jesus 16 February 2016 (has links)
The working condition of the electrical transmission systems is a factor that takes a lot of concern among energy suppliers and users. To maintain appropriate conditions for operation of the system is important in all aspects. For this purpose, several devices are used, monitoring and protection electrical devices, for example. These include the fault current limiter, with this device you can limit the fault current in the bus or lines of the electrical system. In this work, it is proposed to accomplish the selection and allocation of fault current limiters devices in electrical systems to minimize the short-circuit current, considering the device cost and the cost due to technical losses. For this, it has been used the multi-objective genetic algorithm NSGA-II for his known efficiency in optimization problems in electrical systems. The proposed algorithm was applied in benchmark systems, a 30-bus and a 57-bus, and the systems were simulated with and without the presence of the devices for comparison and validation of results. / A condição de funcionamento dos sistemas elétricos de transmissão é um fator que demanda muita preocupação por parte dos fornecedores e usuários de energia. Manter condições adequadas para a operação do sistema é importante em todos os aspectos. Para este fim, vários equipamentos são utilizados, dispositivos elétricos de monitoramento e proteção, por exemplo. Entre eles, estão os dispositivos limitadores de corrente de curto-circuito. Com este dispositivo é possível limitar a corrente de falta nas barras ou linhas do sistema elétrico. Neste trabalho, propõe-se realizar a seleção e alocação de dispositivos limitadores de corrente de curto-circuito em sistemas elétricos de modo a minimizar a corrente de curto-circuito, considerando o custo do dispositivo e o custo devido à perdas técnicas. Para isso, foi utilizado o algoritmo genético multiobjetivo NSGA-II por sua já conhecida eficiência em problemas de otimização em sistemas elétricos. O algoritmo proposto foi aplicado em sistemas teste de 30 e 57 barras e os sistemas foram simulados com e sem a presença dos dispositivos para efeito de comparação e validação dos resultados.

Page generated in 0.0459 seconds