• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 1
  • Tagged with
  • 35
  • 35
  • 17
  • 17
  • 15
  • 12
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Localização de faltas em alimentadores de distribuição de energia elétrica usando medições esparsas de tensões

Pereira, Rodrigo Aparecido Fernandes [UNESP] 02 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-02Bitstream added on 2014-06-13T19:40:20Z : No. of bitstreams: 1 pereira_raf_dr_ilha.pdf: 1085197 bytes, checksum: 8d25137a551ef06a95af7c5112ebbaf6 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Neste trabalho, é proposto um algoritmo para localização de faltas em alimentadores radiais aéreos de distribuição de energia elétrica. A técnica proposta aplica-se a alimentadores trifásicos com cargas desequilibradas, que podem possuir ramais laterais trifásicos, bifásicos e monofásicos. As equações da rede que compõem esta técnica foram desenvolvidas com base nos métodos de fluxo de potência do tipo varredura (backward/forward sweep), o que a torna uma ferramenta eficiente e de baixo esforço computacional. No desenvolvimento da mesma, considera-se que haja disponibilidade de medições de tensões no nó inicial do alimentador e também medições esparsas de tensão em alguns pontos ao longo do alimentador de distribuição. Esta técnica apresenta algumas vantagens quando comparada com as técnicas convencionais para localização de faltas que utilizam o deslocamento do local da falta na rede. Nela eliminam-se, dos possíveis locais de falta, os pontos que estão em ramais laterais geograficamente distantes do verdadeiro local da falta e que poderiam ser indicados pelos métodos convencionais de localização da faltas. Adicionalmente à técnica para localização de faltas, é proposto um modelo matemático de programação binária para fazer a alocação otimizada de medidores esparsos de tensões ao longo do alimentador com o propósito de melhorar a precisão do algoritmo desenvolvido, a partir da técnica proposta para a localização de faltas. Neste modelo matemático, busca-se manter a melhor relação custo-benefício para as empresas de energia, em termos de investimentos, custos operacionais e melhorias dos seus índices de confiabilidade, com a localização eficiente de faltas em suas redes de distribuição. Para a solução deste modelo matemático, propõe-se... / An algorithm for fault location on overhead and radial electric power distribution feeders is proposed in this work. The proposed technique is able to be applied to three-phase feeders containing unbalanced loads. Also, the proposed technique has the ability to deal with feeders which has three-, two- or single-phase laterals. Equations that describe the network are derived based on the backward/forward sweep load flow methods. This characteristic makes the proposed fault location technique an efficient and fast computational tool. In order to develop this technique, it was considered that voltage measurements are available at the sending node of the feeder, as well sparse voltage measurements at some places on the feeder. Thus, this technique presents some advantages in comparison to the traditional technique for fault location which finds the faulty point by means of sliding the analyzed point on the network. By using traditional techniques, points located geographically far from the actual faulty point can be indicated as a faulty point. The proposed technique eliminates these points from the results. Additionally to the proposed technique, a binary programming model is presented for carrying out the optimized placement of voltage measurement devices along the feeder. The goal of this binary programming model is to enhance the accuracy of the proposed algorithm for fault location. This mathematical model is aimed at keeping the best costbenefit rate for the electric utilities, in terms of operational costs and improvements of reliability indices by means of an efficient fault location. A dedicated genetic algorithm is proposed for solving the optimization model. Results and simulation analyses are presented in order to validate the efficiency... (Complete abstract click electronic access below)
12

Automação e garantia da confiabilidade metrológica em ensaio de cuto-circuito em baixa tensão

Costa, Ronny January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Metrologia Científica e Industrial. / Made available in DSpace on 2013-07-16T02:22:59Z (GMT). No. of bitstreams: 0 / O sistema de fornecimento de energia elétrica inclui as etapas de geração, transmissão, distribuição e consumo. Em cada uma dessas etapas são previstos equipamentos de proteção para garantir a integridade do sistema em caso de falha. Uma falha típica é o curto-circuito. Em baixa tensão, os equipamentos que executam a função de proteção, objetivando minimizar os efeitos da falha de curto-circuito, são os disjuntores e os fusíveis. Portanto, é de grande importância o desempenho desses equipamentos em uma situação de curto-circuito. A garantia da confiabilidade operacional de tais sistemas é baseada em ensaios. Nos ensaios de curto-circuito, a exemplo do que acontece com a maioria dos ensaios elétricos, observa-se, historicamente, pequena preocupação com as questões metrológicas. Mesmo quando existe a preocupação com a confiabilidade metrológica, é raro que os procedimentos aplicados para avaliação de incertezas e análise de confiabilidade sejam feitos de acordo com estado-da-arte em metrologia. A proposta do trabalho é fazer uma análise detalhada do ensaio de curto-circuito em baixas tensões. São analisados, do ponto de vista metrológico, os equipamentos usuais de medição e controle. É feita uma proposta de estruturação de um sistema automatizado de ensaio. É feito o desenvolvimento parcial do sistema e uma avaliação das incertezas de medição das grandezas mais críticas, para avaliação do comportamento metrológico dos sistemas de medição e de controle do ensaio.
13

Representação de curto-circuito probabilístico na avaliação da confiabilidade de sistemas de distribuição

Calado, Dianne Elissa Desan January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:29:34Z (GMT). No. of bitstreams: 1 338905.pdf: 3495532 bytes, checksum: 0a96893c7bca0e06c95a5200a221a216 (MD5) Previous issue date: 2015 / Cargas mais sensíveis a variações de tensão de curta duração demandam melhorias no serviço de entrega da eletricidade. A atual avaliação da adequação de sistemas de distribuição de energia considera apenas índices de confiabilidade baseados em interrupções, que não refletem a percepção completa do consumidor sobre qualidade do fornecimento de energia. Assim, este trabalho inclui a modelagem do curto-circuito na avaliação da confiabilidade, com a utilização de um processo de Markov contínuo para representação da natureza estocástica das faltas transitórias e o método Monte Carlo Sequencial para simulação computacional da confiabilidade do sistema de distribuição. No calculo das correntes de curto-circuito o sistema e representado por todas as fases, retratando o sistema de distribuição naturalmente desbalanceado, incluindo faltas assimétricas. A abordagem desenvolvida e aplicada ao um sistema teste do IEEE de 34 nos e posteriormente a um sistema real. Os resultados das simulações mostraram que e possível estimar indicadores além da simples avaliação de uma interrupção, ampliando o escopo da avaliação da confiabilidade. A metodologia proposta pretende ser incluída no planejamento de sistemas de distribuição.<br> / Abstract : More loads sensitive to short duration voltage variations require improvements in the electricity delivery service. The current evaluation of distribution systems adequacy only considers reliability indices based on interruptions, that do not reflect the entire customer perception about quality on electric energy supply. So, the present dissertation include short-circuit models on the reliability assessment, using a continuous Markov process to represent the stochastic nature of transient faults and a Sequential Monte Carlo method to assess reliability by computer simulation. In order to calculate short-circuit currents, all phases are considered, showing the naturally unbalanced distribution system, including asymmetrical faults. The developed approach is applied to an IEEE test system with 34 nodes and then to a real system. The simulation results show that it is possible to estimate indices beyond a simple evaluation of an interruption, expanding the scope of reliability assessment. The proposed methodology intends to be included in the planning of distribution systems.
14

Representação de curto-circuito probabilístico na avaliação da confiabilidade de sistemas de distribuição

Calado, Dianne Elissa Desan January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T12:51:10Z (GMT). No. of bitstreams: 1 338905.pdf: 3495532 bytes, checksum: 0a96893c7bca0e06c95a5200a221a216 (MD5) Previous issue date: 2015 / Cargas mais sensíveis a variações de tensão de curta duração demandam melhorias no serviço de entrega da eletricidade. A atual avaliação da adequação de sistemas de distribuição de energia considera apenas índices de confiabilidade baseados em interrupções, que não refletem a percepção completa do consumidor sobre qualidade do fornecimento de energia. Assim, este trabalho inclui a modelagem do curto-circuito na avaliação da confiabilidade, com a utilização de um processo de Markov contínuo para representação da natureza estocástica das faltas transitórias e o método Monte Carlo Sequencial para simulação computacional da confiabilidade do sistema de distribuição. No calculo das correntes de curto-circuito o sistema e representado por todas as fases, retratando o sistema de distribuição naturalmente desbalanceado, incluindo faltas assimétricas. A abordagem desenvolvida e aplicada ao um sistema teste do IEEE de 34 nos e posteriormente a um sistema real. Os resultados das simulações mostraram que e possível estimar indicadores além da simples avaliação de uma interrupção, ampliando o escopo da avaliação da confiabilidade. A metodologia proposta pretende ser incluída no planejamento de sistemas de distribuição.<br> / Abstract : More loads sensitive to short duration voltage variations require improvements in the electricity delivery service. The current evaluation of distribution systems adequacy only considers reliability indices based on interruptions, that do not reflect the entire customer perception about quality on electric energy supply. So, the present dissertation include short-circuit models on the reliability assessment, using a continuous Markov process to represent the stochastic nature of transient faults and a Sequential Monte Carlo method to assess reliability by computer simulation. In order to calculate short-circuit currents, all phases are considered, showing the naturally unbalanced distribution system, including asymmetrical faults. The developed approach is applied to an IEEE test system with 34 nodes and then to a real system. The simulation results show that it is possible to estimate indices beyond a simple evaluation of an interruption, expanding the scope of reliability assessment. The proposed methodology intends to be included in the planning of distribution systems.
15

Otimização da parametrização de relés em sistemas radiais de distribuição de energia elétrica com utilização do algoritmo genético

Silva, Marcos Antonio de Araújo 02 May 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-07-03T15:26:00Z No. of bitstreams: 1 MarcosAntonioDeAraujoSilva_DISSERT.pdf: 1854752 bytes, checksum: 967e430cde995be91861c9969e8e0d2c (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-07-11T12:47:42Z (GMT) No. of bitstreams: 1 MarcosAntonioDeAraujoSilva_DISSERT.pdf: 1854752 bytes, checksum: 967e430cde995be91861c9969e8e0d2c (MD5) / Made available in DSpace on 2018-07-11T12:47:42Z (GMT). No. of bitstreams: 1 MarcosAntonioDeAraujoSilva_DISSERT.pdf: 1854752 bytes, checksum: 967e430cde995be91861c9969e8e0d2c (MD5) Previous issue date: 2018-05-02 / As concessionárias de energia elétrica buscam permanentemente ampliar e modernizar os sistemas elétricos de potência frente às novas demandas dos consumidores e exigências estabelecidas pela Agência Nacional de Energia Elétrica. A proteção de sistemas elétricos tem papel fundamental na manutenção deste sistema e no controle de seus indicadores. Sistemas de distribuição possuem diversas particularidades físicas e técnicas, como o tempo de operação dos dispositivos, fluxos de carga e níveis de curto-circuito. Diante da grande diversidade destes sistemas, a construção de um algoritmo computacional que auxilie nos procedimentos matemáticos de parâmetros do sistema, ou ainda, que gere uma prévia configuração automática dos dispositivos, é necessária perante à ampla demanda ofertada aos engenheiros de proteção. O algoritmo foi modelado inicialmente com o objetivo de determinar as correntes de curto-circuito em cada dispositivo de proteção primária, assim como calcular as correntes mínimas de atuação das unidades de sobrecorrente temporizada e os ajustes de temporização dos relés. Porém, devido ao grande universo de possibilidades de ajustes oferecidos pelo código, fez-se necessária a utilização das técnicas da biologia evolutiva, com o intuito de escolher neste universo de possibilidades o indivíduo que torne a parametrização deste sistema otimizada. Se na primeira geração, o indivíduo escolhido não condisser com a função ótima, esta população será evoluída a partir dos procedimentos de seleção natural, cruzamento e mutação dos indivíduos, presentes nas técnicas de evolução utilizada nos Algoritmos Genéticos. Espera-se que a codificação genética, quando aplicada nos dispositivos microprocessados com característica de intervalo de tempo adequado segundo as normas, o algoritmo se mostre eficiente e estável. Já para os circuitos alimentadores nos quais a temporização dos equipamentos esteja inadequada para um estudo fidedigno de coordenação e seletividade, serão sugeridas mudanças de alguns parâmetros de temporização inicial. Caso o tempo de operação absoluto do alimentador seja minimizado, o procedimento realizado pelo algoritmo será considerado válido e a configuração apresentada ao final será a melhor entre todas da população. / Energy concessionaires are constantly seeking to expand and modernize power systems in face of new consumer demands and requirements established by the National Electric Energy Agency. The protection of electrical systems plays a fundamental role in the maintenance of this system and in the control of its indicators. Distribution systems have several physical and technical characteristics, such as the operating time of the devices, load flows and short-circuit levels. In view of the great diversity of these systems, the construction of a computational algorithm that assists in the mathematical procedures of system parameters, or even that, generate a previous automatic configuration of the devices is necessary in view of the wide demand offered to the protection engineers. The algorithm was initially modeled in order to determine the short-circuit currents in each primary protection device, as well as to calculate the minimum currents of operation of the time-overcurrent units and the timing adjustments of the relays. However, due to the great universe of possibilities of adjustments offered by the code, it became necessary to use the techniques of evolutionary biology in order to choose in this universe of possibilities the individual that makes the parameterization of this system optimized. If in the first generation the chosen individual does not match the optimal function, this population will be evolved from the procedures of natural selection, crossing and mutation of the individuals, present in the evolutionary techniques used in the Genetic Algorithms. It is expected that the genetic coding when applied to microprocessor devices with appropriate time interval characteristics according to standards, the algorithm is efficient and stable. However, for feeder circuits where equipment timing is inadequate for a reliable study of coordination and selectivity, changes in some initial timing parameters will be suggested. If the absolute operation time of the feeder is minimized the procedure performed by the algorithm will be considered valid and the configuration presented at the end will be the best among all of the population.
16

Simulação para a avaliação do desempenho do sistema de proteção de distância de uma linha de transmissão de 500 KV / Simulation for performance evaluation system of distance protection of a transmission line 500 KV

Oliveira, Wagner de, 1960- 21 August 2018 (has links)
Orientador: Fujio Sato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T20:17:53Z (GMT). No. of bitstreams: 1 Oliveira_Wagnerde_M.pdf: 29762769 bytes, checksum: a8dc59d5c389eb687d639b8519c57213 (MD5) Previous issue date: 2012 / Resumo: Neste trabalho, intitulado "Simulação para a Avaliação do Desempenho do Sistema de Proteção de Distância de uma Linha de Transmissão de 500 kV", são descritos os princípios básicos das proteções dos sistemas de potência, a evolução dos equipamentos e dos procedimentos de ensaios, simulações em tempo real, análise de desempenho de um sistema de proteção de linha de transmissão e simulações no modelo computacional. Nos Capítulo 1 e 2 são destacados alguns aspectos importantes do sistema de potência, seguido de noções de proteção de linhas de transmissão, realçando os relés de distância e o esquema de teleproteção. No Capítulo 3 são descritos a evolução dos equipamentos e procedimentos para os ensaios, concomitante aos avanços tecnológicos dos relés de proteção, desde os relés eletromecânicos até os relés numéricos. No Capítulo 4 são descrito as simulações em tempo real e as análises dos resultados. Estas simulações foram executadas na LT 500 kV Tucuruí-Vila do Conde que integra o Sistema Norte-Nordeste da ELETRONORTE e EATE, utilizando o RTDS. As saídas em forma de sinais analógicos (tensões e correntes) e digitais (eventos) possibilitaram as análises de desempenhos dos relés, do sistema de teleproteção e disjuntores. E no Capítulo 5 temos a parte final da dissertação, demonstrando o desenvolvimento de um modelo computacional para simular as trajetórias das impedâncias de faltas de forma a confrontá-las com as características quadrilaterais de impedância do relé de distância REL 531 no plano R-X utilizado durante a simulação no RTDS, o que permitiu a análise dos ajustes das zonas de proteção / Abstract: This work, entitled "Simulation for Performance Evaluation System of Distance Protection of a Transmission Line 500 kV," describes the basic principles of protection of power systems, the evolution of equipment's and testing procedures, real-time simulations performance analysis of a system of protection of transmission line and the computer model simulations. In Chapter 1 and 2 are highlights some important aspects of the power system, followed by notions of protection of transmission lines, enhancing distance relays and pilot relaying scheme. In Chapter 3 describes the evolution of equipment and procedures for testing, concomitant technological advances of protective relays from electromechanical relays by numerical relays Described in Chapter 4 are the real-time simulations and analyzes of the results. These simulations were performed at 500 kV Tucuruí-Vila do Conde system which integrates the North and Northeast ELETRONORTE and EATE using the RTDS. The outputs in the form of analog signals (voltages and currents) and digital signals (events) enabled the analysis of performances of relays, pilot relaying scheme (teleprotection system) and circuit breakers. In the Chapter 5, we have the final part of the dissertation, demonstrating the development of a computational model to simulate the trajectories of impedances faults in order to compare them with the quadrilateral characteristics parameters of the distance protection zones REL 531 line protection plane used during R-X RTDS simulation, which allowed the analysis of the protection zone adjustments / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
17

Contribuição ao estudo do motor de indução monofasico com capacitador chaveado

Almeida, José Francisco Marcondes de 31 March 2000 (has links)
Orientador: Edson Bim / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T02:19:27Z (GMT). No. of bitstreams: 1 Almeida_JoseFranciscoMarcondesde_M.pdf: 3295187 bytes, checksum: 42264ed158c326964081fa1d1520c625 (MD5) Previous issue date: 2000 / Resumo: Este trabalho tem como finalidade descrever a obtenção de capacitâncias variáveis a partir do chaveamento de um capacitor para aplicação em motores de indução monofásicos. Tradiciona1mente, neste tipo de motor, utiliza-se uma chave centrífuga com um capacitor para a partida e outro para o regime. Um método alternativo propõe a substituição da chave centrífuga e do capacitor de partida por uma chave a estado sólido ligada em paralelo com o capacitor de regime. Os dois métodos são analisados, implementados e comparados. Resultados de simulação demonstram a obtenção de capacitâncias maiores através de curtoscircuitos programados no capacitor de regime. Os resultados experimentais foram obtidos através de um sistema de desenvolvimento baseado no microcontrolador 87Cl96KD da Intel / Abstract: The main purpose of this work is to obtain the variable capacitances from a switched capacitor for application in single-phase induction motors. Traditionally, this motor, uses a centrifugal switch with a starting capacitor and a running capacitor. An alternative method replaces the centrifugal switch and the starting capacitor by a solid-state switch in parallel with the running capacitor. The two methods are analyzed, implemented and compared. Simulations results show the increase of the capacitance through programmed short-circuits of the running capacitor. The experimental results are obtained through a development system based on the 87C196KD microcontroller of the Intel / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
18

Um estudo comparativo da analise de curto-circuito probabilistico em ambientes paralelo e distribuido

Sato, Fujio, 1944- 20 July 2018 (has links)
Orientadores: Alcir Jose Monticelli, Ariovaldo Verandio Garcia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T14:56:15Z (GMT). No. of bitstreams: 1 Sato_Fujio_D.pdf: 8110910 bytes, checksum: ae60d1e9b50e670431be8430488de6e4 (MD5) Previous issue date: 1995 / Resumo: Este trabalho apresenta a paralelização de um programa de análise de curto-circuito probabilístico utilizando o método de Monte Cado para sistemas de potência. O programa, originariamente desenvolvido e implementado em computadores seqüenciais, foi codificado para dois ambientes distintos de alto desempenho (paralelo e distribuído), tendo como um dos objetivos a verificação de alguns itens importantes concernentes ao processamento paralelo, tais como: portabilidade, desempenho, escalabilidade e comunicação. As implementações paralela e distribuída desta aplicação foram feitas com dois modelos de programação concorrente: o SP M D (Single Process Multiple Data) e o Mestre/Escravo. Os resultados foram obtidos através de testes em quatro sistemas elétricos da região Sul-Sudeste do Sistema Interligado brasileiro / Abstract: This work presents the parallelization of a power system probabilistic short-circuit analysis program using Monte Gar/o method. A sequential version of the code, originally developed for one-processor machine, was extended to two different high performance computer system architectures (parallel and distributed). The main objective of the research was to study issues such as portability, performance, scalability and communication. Two programming models have been implemented on both architectures: SP MD, (Single Process Multiple Data) and MasterjSlave. The architectures and the models have been evalueted by simulation on four real-life networks of the brazilian South-Southeast interconnected system / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
19

Detecção e classificação de curto-circuitos em sistemas de distribuição usando rede neural artificial ARTMAP nebulosa /

Martins, João Roberto Deroco. January 2010 (has links)
Orientador: Jozué Vieira Filho / Banca: Anna Diva Plasencia Lotufo / Banca: Marco Aparecido Queiroz Duarte / Resumo: Este trabalho apresenta uma metodologia para detecção e classificação de faltas do tipo curto-circuito. Esta operação de diagnóstico tem como principal operador um banco de redes neurais artificiais (RNAs) do tipo ARTMAP Nebulosa. Tal ferramenta segue a principal filosofia das RNAs: o reconhecimento de padrões, através de um trei- namento supervisionado inicial, responsável por atualizar os parâmetros das redes con- comitantemente com os resultados desejados. Finalizada a fase de adaptação, as redes serão capazes de, após receber novos padrões, classificá-los, de forma a propiciar, ao operador, informações importantes quanto ao estado de transmissão de barras presentes em um determinado complexo elétrico. Aqui, tomou-se como modelo a simulação de um grande alimentador real, composto por mais de 800 barras. Aliados às RNAs, tam- bém foram aplicadas, no que se refere à análise de dados amostrados de corrente elétri- ca, duas importantes e flexíveis ferramentas matemáticas: a Transformada de Fourier e a Transformada Wavelet. .Observa-se, ao final do trabalho, que os resultados apresenta- dos são bastante encorajadores, o que possibilitaria a utilização do programa em um ambiente real / Abstract: This work presents a detection and classification of short-circuit faults metho- dology. The main operator of this diagnostic operation is a Fuzzy ARTMAP Artificial Neural Networks (ANN) bank. This tool follows the ANN's main core: pattern recogni- tion, through an initial supervised training stage, responsible for updating the parame- ters of the networks con-comitant with the desired results. Completed the adaptation phase, the network will be able to, after receiving new standards, classifying them in order to provide to the operator important information about the state of transmission of bars present in a given complex electric. Here, there is, like a model, a simulation of a real big feeder, comprising more than 800 bars. Besides the ANNs, two important and flexible mathematical tools were also applied with regard to the analysis of sampled data of electric current: Fourier Transform and Wavelet Transform. At the end of the work the results presented are very encouraging, which would allow the use of the pro- gram in a no simulations real environment / Mestre
20

Um método para detecção e classificação de curtos-circuitos em redes de distribuição de energia elétrica baseado na transformada de Fourier e em redes neurais artificiais

Matos, Élito dos Reis [UNESP] 28 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-28Bitstream added on 2014-06-13T18:08:26Z : No. of bitstreams: 1 matos_er_me_ilha.pdf: 2466056 bytes, checksum: fd089ec7147abd26c94fadfe5e17bb85 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho apresenta-se uma Metodologia para Detecção e Classificação de Curtos-Circuitos em alimentadores de Sistemas de Distribuição de Energia Elétrica fundamentada na análise de registros oscilográficos através da DFT (Discrete Fourier Transform) e de RNAs (Redes Neurais Artificiais). Sua aplicação pressupõe a disponibilidade de registros de oscilografia digital das correntes nas três fases do alimentador, monitoradas apenas na saída da subestação. A caracterização de cada tipo de curto-circuito é obtida mediante a análise do comportamento dinâmico das correntes de fase durante o período transitório das faltas e a detecção e classificação dos curtos-circuitos são efetuadas por meio de um banco de RNAs acíclicas, do tipo perceptrons, de múltiplas camadas. Um modelo de um alimentador real de Sistema de Distribuição de grande porte, composto por 836 barras, foi utilizado na obtenção dos dados referentes aos curtos-circuitos, com simulações via software ATP-EMTP (Alternative Transients Program - Electromagnetic Transients Program). O método foi implementado e testado utilizando-se o software MATLAB®. Como resultado tem-se uma metodologia de formulação simples que apresenta bom desempenho, é de fácil implementação, apresenta baixa carga computacional e gera resultados altamente satisfatórios / This work proposes a methodology for Detection and Classification of Short-Circuits in Distribution Electric Power feeders, based on the analysis of oscillograph records through the application of DFT (Discrete Fourier Transform) and ANNs (Artificial Neural Networks). Its application requires the availability of digital oscillograph records of the currents in the three phases of the feeder, only monitored at the output of the substation. The characterization of each type of short-circuit is obtained by means of analysis of the dynamic behavior of the phase currents during the transitory period. The detection and classification of short-circuits is performed by a bank of acyclic ANNs, of type multilayers perceptrons. A real feeder model of a large distribution power system, composed of 836 buses, was used to obtain data relating to short-circuits, simulated via ATP-EMTP (Alternative Transients Program - Electromagnetic Transients Program) software. The method was implemented and tested using MATLAB®. As a conclusion, the proposed method is simple to be implemented, presents low computational load and generates good results

Page generated in 0.0515 seconds