• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 1
  • Tagged with
  • 35
  • 35
  • 17
  • 17
  • 15
  • 12
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modelo estocástico de programação matemática de alocação de medidores de tensão em alimentadores radiais de distribuição de energia elétrica para localização de faltas e monitoramento do perfil de tensão

Bíscaro, André do Amaral Penteado [UNESP] 18 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-18Bitstream added on 2014-06-13T18:49:30Z : No. of bitstreams: 1 biscaro_aap_me_ilha.pdf: 1057545 bytes, checksum: feb928c10ad58cb9fc7bef33003e6afc (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Neste trabalho é proposta uma técnica de otimização para alocar medidores dispersos de tensão em alimentadores radiais aéreos de distribuição baseada na metaheurística Greedy Randomized Adaptive Search Procedure (GRASP), com o objetivo de melhorar o desempenho de algoritmos de localização de faltas que utilizam informações esparsas de tensão e, simultaneamente, fazer o controle em tempo real do nível de tensão do alimentador operando sob diferentes cenários. No modelo de programação proposto para alocar os medidores considera-se a natureza estocástica das variáveis envolvidas no problema relacionado com o estudo de contingências em sistemas de energia elétrica, ou seja: carregamento dos transformadores da rede no instante de ocorrência da falta, impedância de falta, probabilidade de falhas e erros de medição dos medidores dispersos de tensão, probabilidade de ocorrer qualquer um dos tipos de faltas possíveis, entre outros. O modelo da função objetivo contempla a localização de faltas com boa precisão para qualquer algoritmo que utiliza medições esparsas de tensão e os menores valores de magnitudes de tensão no alimentador, operando em condições normais ou sob contingências. Apresentam-se resultados de testes com a metodologia proposta para dois alimentadores reais de distribuição de energia elétrica. O primeiro alimentador é de médio porte, tensão nominal de 13,8 kV e possui 134 barras. O segundo alimentador é de grande porte, tensão nominal de 11,4 kV e possui 3287 barras. / This work proposes an optimization technique to allocate voltage measurement devices on radial overhead electric power distribution feeders based on Greedy Randomized Adaptive Search Procedure (GRASP) metaheuristic, aiming at improving the performance of algorithms for fault location using sparse voltage information, while making the real time control of the feeder’s operating voltage under different scenarios. The proposed programming model to allocate the devices considers the nature of the stochastic variables involved in the problem with the study of contingencies in electric power systems: loading of the network transformers at time of occurrence of failure, fault impedance, probability of failures and errors of measurement of dispersed voltage devices, likelihood that any of the possible types of faults occur, among others. The model's objective function includes the faults location procedure with good precision for any algorithm that uses sparse measurements of voltage and the lowest values of the magnitudes of voltage feeder, operating under normal conditions or contingencies. Test results with the proposed methodology applied to simulated data of two real life feeders are presented. The first feeder is medium size, rated voltage of 13.8 kV and has 134 bars. The second feeder is large, rated voltage of 11.4 kV and has 3287 bars.
22

Metodologia generalizada para análise em regime permanente de sistema de distribuição de energia elétrica / Generalized methodology for steady state analysis of distribution power system

Barbosa, Tiago de Moraes, 1988- 25 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T07:49:42Z (GMT). No. of bitstreams: 1 Barbosa_TiagodeMoraes_M.pdf: 5056910 bytes, checksum: e6df43d1508493560aa5e60a3182b1e1 (MD5) Previous issue date: 2014 / Resumo: Visando manter a qualidade da energia elétrica entregue aos consumidores e atender os critérios de operação impostos pelos órgãos reguladores dos sistemas elétricos, necessita-se realizar análi-ses técnicas em sistemas de distribuição de energia. Os principais estudos realizados são os de cálculo de fluxo de potência, cálculo de curto-circuito e também análises da distorção harmônica. Um problema encontrado atualmente é que apesar de muitos métodos serem desenvolvidos com o objetivo de auxiliar na realização destes estudos, geralmente cada método é dedicado a um tipo de análise, ou seja, não há uma integração entre as diversas ferramentas de análise de rede, o que acaba dificultando o trabalho do engenheiro da concessionária. Com o objetivo de integrar as principais análises do setor de distribuição em uma única ferramenta, neste trabalho foi imple-mentada uma metodologia generalizada com capacidade para encontrar a solução para problemas de sistemas multifásicos, unificando os cálculos de fluxo de potência na frequência fundamental, fluxo de potência em frequências harmônicas e curto-circuito. Neste contexto, entre as vantagens do programa desenvolvido destacam-se: (a) unificação das principais ferramentas de estudos em sistemas de distribuição ¿ fluxo de potência, curto-circuito e fluxo de potência harmônico; (b) modelagem multifásica ¿ essa modelagem permite representar explicitamente o neutro e diferen-tes características de aterramento (por exemplo, sistemas multiaterrados); (c) robustez ¿ o método de solução utilizado é o Newton-Raphson; (d) flexibilidade ¿ cada componente da rede é mo-delado por ramo, permitindo maior flexibilidade na representação de diferentes conexões dos equipamentos; (e) o algoritmo foi implementado utilizando-se linguagem de programação Python. Este trabalho apresenta detalhes da formulação utilizada e a validação do algoritmo pela comparação dos resultados obtidos com os resultados de programas de análise de sistemas de potência bastante conhecidos / Abstract: Technical analyses applied to distribution systems are needed in order to guarantee the quality in electric energy delivered to the customers and to meet the regulatory requirements. The main studies performed with these purposes are power flow, short-circuit and harmonic power flow analyses. A current problem is that, although many methods have been developed to assist these studies, generally each method is dedicated to one type of study. In other words, there is no inte-gration between the several tools of network analysis, making the work of utility engineer a dif-ficult task. In order to integrate the main distribution system analyses into a single tool, in this work, it was implemented a generalized method with the capability of finding the solution for multiphase system problems, allowing the power flow calculation in fundamental and harmonic frequencies as well as short-circuit analyses. In this context, the main advantages of the devel-oped program are: (a) unification of the main tools applied to distribution systems studies ¿ fun-damental and harmonic frequencies power flow and short-circuit studies; (b) multiphase model-ing ¿ the models allows to represent multiple phases, neutral and different grounding topologies (for instance, multigrounded); (c) robustness ¿ the solution method is Newton-Raphson; (d) flex-ibility ¿ each network component is modeled as a branch, resulting in a higher flexibility in rep-resentation of different equipment connections; (e) the algorithm was implemented using Python programming language. This work presents details of the method formulation and the algorithm validation by the comparison of the obtained results with the results from well-known power system analyses software / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
23

Alocação otimizada de medidores em sistemas de distribuição visando à redução da múltipla localização de faltas / Optimized monitors allocation in distribution systems aiming to reduction of the multiple fault location

Martins, Paulo Estevão Teixeira 19 February 2019 (has links)
Essa pesquisa propõe abordar o problema da alocação de medidores em sistemas de distribuição, de forma a reduzir os custos, garantindo o monitoramento dos distúrbios que afetam a qualidade da energia elétrica, mas também de obter alocações de medidores que facilitem a localização do curto-circuito. O problema de otimização é formulado por meio da programação linear inteira e resolvido por meio de algoritmos adequados para implementar cada modelagem matemática. São considerados sistemas testes com diferentes características, com destaque para a presença de linhas monofásicas e/ou bifásicas, linhas heterogêneas e geradores distribuídos acoplados na rede de distribuição principal. O problema de otimização clássico (reduzir custos garantindo o monitoramento) é retomado e é proposta uma modelagem mais geral, aplicável também a sistemas de distribuição com a presença de ramais monofásicos e/ou bifásicos. A parte da modelagem voltada para o problema da localização de faltas visa à redução das situações de múltipla estimação do local da falta, caracterizadas pela existência de múltiplos pontos no sistema com a mesma distância elétrica até a subestação. Esses dois modelos foram resolvidos separadamente, como dois problemas de otimização mono-objetivo, e em conjunto, sendo portanto, um problema multi-objetivo. As instâncias testadas incluem conjuntos de faltas de todos os tipos, simuladas ao longo das linhas do sistema, considerando a variação da impedância de falta. Os resultados apresentaram soluções de monitoramento para os dois sistemas testes considerados contendo entre 2 e 7 medidores. As soluções alcançadas são atrativas para a concessionária, pois requerem baixo custo de investimento e manutenção dos equipamentos e da infraestrutura de comunicação. A metodologia proposta apresentou alocações dispostas estrategicamente que garantem o monitoramento da qualidade da energia elétrica e minimizam o problema da múltipla estimação da falta, possibilitando o seu uso como suporte a um sistema localizador de faltas. / This research proposes to address the monitors allocation problem in distribution systems, aiming to reduce costs, ensuring the monitoring of disturbances affecting the power quality, but also to obtain monitoring systems that facilitate the process of fault location. The optimization problem is formulated through integer linear programming and solved by suitable algorithms for each mathematical modeling. Test systems with different characteristics, emphasis on the presence of single-phase and/or biphasic lines, heterogeneous lines and distributed generators were considered. The classic optimization problem (reduce costs by ensuring disturbance monitoring) is covered and a more general modeling is proposed, also applicable to distribution systems with the presence of single-phase and/or biphasic branches. The process of fault location is supported through the reduction of the multiple estimation of fault location, characterized by the existence of multiple points in the system with the same electrical distance to the substation. These two models were solved separately, as two mono-objective optimization problems, and together, in a multi-objective perspective. The tested instances include sets of faults of all types, simulated along the lines of the system, considering the fault impedance variation. The results presented monitoring solutions for the two test systems considered containing between 2 and 7 meters. The solutions achieved are attractive to the utility, as they require low investment and maintenance costs for equipment and communication infrastructure. The proposed methodology presented allocations strategically placed that guarantee the power quality monitoring and minimize the multiple estimation problem, allowing its use as support to a faults locator system.
24

Análise de faltas e cálculo de curto-circuito em sistemas de distribuição de energia elétrica com fontes renováveis de geração de energia /

Reiz, Cleberton January 2019 (has links)
Orientador: Jônatas Boás Leite / Resumo: A análise de curto-circuito é um método extremamente importante para os sistemas de energia elétrica (SEE), pois fornece os parâmetros necessários para o dimensionamento adequado dos equipamentos elétricos e ajuste dos dispositivos de proteção que garantem a segurança do SEE e contribuem para a redução dos riscos associados às pessoas próximas ao SEE. Assumindo o atual cenário de intensa inserção de fontes de energia renováveis no SEE, este trabalho propõe métodos e modelos matemáticos para representar os geradores distribuídos de fontes renováveis e não renováveis na análise de curto-circuito em sistemas de distribuição. As características da corrente de curto-circuito de quatro tecnologias de geradores distribuídos são apresentadas: síncrono, indução, fotovoltaico e gerador de indução duplamente alimentado (DFIG, do inglês, Doubly Fed Induction Generator). Neste trabalho considera-se um sistema elétrico trifásico desbalanceado real onde são realizadas simulações de faltas mono-, bi- e trifásicas permitindo, assim, avaliação e compreensão dos efeitos dessas tecnologias nas correntes de curto-circuito em redes de distribuição. Na análise de curto-circuito proposta, o método de varredura para cálculo do fluxo de potência em sistemas radiais, e/ou fracamente malhados, é utilizado na obtenção das condições de operação do sistema de distribuição. A determinação da matriz de impedância nodal com redução de Kron para cada gerador presente no SEE e o princípio da superposição são ut... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
25

Medidas de informação e sistemas inteligentes aplicados no diagnóstico de curto-circuito do estator de motores de indução trifásicos / Information measures and intelligent systems applied to the stator short-circuit diagnosis in three-phase induction motors

Bazan, Gustavo Henrique 08 July 2016 (has links)
Conselho Nacional do Desenvolvimento Científico e Tecnológico (CNPq) / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / Este trabalho propõe o estudo e desenvolvimento de uma metodologia alternativa de identificação de falhas nos enrolamentos do estator de motores de indução trifásicos conectados diretamente à rede elétrica. A fim de reduzir a dimensão e complexidade destes tipos de sistemas, são utilizadas duas ferramentas de processamento de sinais, extração e seleção de características. Na etapa de extração, calcula-se a informação mútua atrasada dos sinais de correntes das fases A e B da máquina e na seleção, os algoritmos árvore de decisão C4.5 e rede neural artificial MLP são utilizados para a predição das classes, a fim de se obter um sistema de diagnóstico de falhas de estator eficaz. Os resultados experimentais offline e online consideram problemas de qualidade de energia, uma ampla faixa de conjugado de carga e curto-circuito entre as espiras do enrolamento de estator da ordem de 1% à 20%, os quais são apresentados para validar a abordagem desenvolvida neste trabalho. Os resultados obtidos indiciam que esta abordagem pode ser empregada para classificar falhas de curto-circuito entre as espiras do stator. / This work proposes the study and development of an alternative approach to diagnose stator short-circuit faults in induction motors driven directly from a supply line. In order to reduce the size and complexity in these types of systems, signal processing techniques of extraction and feature selection are used. In the extraction step, the mutual information of the delayed phases of current signals, ia and ib, are computed and in the selection procedure, the algorithms C4.5 decision tree and multilayer perceptron neural network are employed in order to obtain an effective diagnostic of stator short-circuit faults. To assess the classification accuracy across the various levels of stator short-circuit fault severity (from 1% to 20%), offline and online experimental tests also considered a wide range of load conditions and voltage unbalance in the power supply. The obtained results indicate that this approach can be employed to classify stator short-circuit faults.
26

Um método para detecção e classificação de curtos-circuitos em redes de distribuição de energia elétrica baseado na transformada de Fourier e em redes neurais artificiais /

Matos, Élito dos Reis. January 2009 (has links)
Orientador: Jozué Vieira Filho / Banca: Carlos Roberto Minussi / Banca: Walmir de Freitas Filho / Resumo: Neste trabalho apresenta-se uma Metodologia para Detecção e Classificação de Curtos-Circuitos em alimentadores de Sistemas de Distribuição de Energia Elétrica fundamentada na análise de registros oscilográficos através da DFT (Discrete Fourier Transform) e de RNAs (Redes Neurais Artificiais). Sua aplicação pressupõe a disponibilidade de registros de oscilografia digital das correntes nas três fases do alimentador, monitoradas apenas na saída da subestação. A caracterização de cada tipo de curto-circuito é obtida mediante a análise do comportamento dinâmico das correntes de fase durante o período transitório das faltas e a detecção e classificação dos curtos-circuitos são efetuadas por meio de um banco de RNAs acíclicas, do tipo perceptrons, de múltiplas camadas. Um modelo de um alimentador real de Sistema de Distribuição de grande porte, composto por 836 barras, foi utilizado na obtenção dos dados referentes aos curtos-circuitos, com simulações via software ATP-EMTP (Alternative Transients Program - Electromagnetic Transients Program). O método foi implementado e testado utilizando-se o software MATLAB®. Como resultado tem-se uma metodologia de formulação simples que apresenta bom desempenho, é de fácil implementação, apresenta baixa carga computacional e gera resultados altamente satisfatórios / Abstract: This work proposes a methodology for Detection and Classification of Short-Circuits in Distribution Electric Power feeders, based on the analysis of oscillograph records through the application of DFT (Discrete Fourier Transform) and ANNs (Artificial Neural Networks). Its application requires the availability of digital oscillograph records of the currents in the three phases of the feeder, only monitored at the output of the substation. The characterization of each type of short-circuit is obtained by means of analysis of the dynamic behavior of the phase currents during the transitory period. The detection and classification of short-circuits is performed by a bank of acyclic ANNs, of type multilayers perceptrons. A real feeder model of a large distribution power system, composed of 836 buses, was used to obtain data relating to short-circuits, simulated via ATP-EMTP (Alternative Transients Program - Electromagnetic Transients Program) software. The method was implemented and tested using MATLAB®. As a conclusion, the proposed method is simple to be implemented, presents low computational load and generates good results / Mestre
27

Modelo estocástico de programação matemática de alocação de medidores de tensão em alimentadores radiais de distribuição de energia elétrica para localização de faltas e monitoramento do perfil de tensão /

Bíscaro, André do Amaral Penteado. January 2009 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Jozué Vieira Filho / Banca: Arturo Suman Bretas / Resumo: Neste trabalho é proposta uma técnica de otimização para alocar medidores dispersos de tensão em alimentadores radiais aéreos de distribuição baseada na metaheurística Greedy Randomized Adaptive Search Procedure (GRASP), com o objetivo de melhorar o desempenho de algoritmos de localização de faltas que utilizam informações esparsas de tensão e, simultaneamente, fazer o controle em tempo real do nível de tensão do alimentador operando sob diferentes cenários. No modelo de programação proposto para alocar os medidores considera-se a natureza estocástica das variáveis envolvidas no problema relacionado com o estudo de contingências em sistemas de energia elétrica, ou seja: carregamento dos transformadores da rede no instante de ocorrência da falta, impedância de falta, probabilidade de falhas e erros de medição dos medidores dispersos de tensão, probabilidade de ocorrer qualquer um dos tipos de faltas possíveis, entre outros. O modelo da função objetivo contempla a localização de faltas com boa precisão para qualquer algoritmo que utiliza medições esparsas de tensão e os menores valores de magnitudes de tensão no alimentador, operando em condições normais ou sob contingências. Apresentam-se resultados de testes com a metodologia proposta para dois alimentadores reais de distribuição de energia elétrica. O primeiro alimentador é de médio porte, tensão nominal de 13,8 kV e possui 134 barras. O segundo alimentador é de grande porte, tensão nominal de 11,4 kV e possui 3287 barras. / Abstract: This work proposes an optimization technique to allocate voltage measurement devices on radial overhead electric power distribution feeders based on Greedy Randomized Adaptive Search Procedure (GRASP) metaheuristic, aiming at improving the performance of algorithms for fault location using sparse voltage information, while making the real time control of the feeder's operating voltage under different scenarios. The proposed programming model to allocate the devices considers the nature of the stochastic variables involved in the problem with the study of contingencies in electric power systems: loading of the network transformers at time of occurrence of failure, fault impedance, probability of failures and errors of measurement of dispersed voltage devices, likelihood that any of the possible types of faults occur, among others. The model's objective function includes the faults location procedure with good precision for any algorithm that uses sparse measurements of voltage and the lowest values of the magnitudes of voltage feeder, operating under normal conditions or contingencies. Test results with the proposed methodology applied to simulated data of two real life feeders are presented. The first feeder is medium size, rated voltage of 13.8 kV and has 134 bars. The second feeder is large, rated voltage of 11.4 kV and has 3287 bars. / Mestre
28

Detecção e classificação de curto-circuitos em sistemas de distribuição usando rede neural artificial ARTMAP nebulosa

Martins, João Roberto Deroco [UNESP] 19 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-19Bitstream added on 2014-06-13T20:09:42Z : No. of bitstreams: 1 martins_jrd_me_ilha.pdf: 2522090 bytes, checksum: f59e117ff382b22406c99cdc0096ef37 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma metodologia para detecção e classificação de faltas do tipo curto-circuito. Esta operação de diagnóstico tem como principal operador um banco de redes neurais artificiais (RNAs) do tipo ARTMAP Nebulosa. Tal ferramenta segue a principal filosofia das RNAs: o reconhecimento de padrões, através de um trei- namento supervisionado inicial, responsável por atualizar os parâmetros das redes con- comitantemente com os resultados desejados. Finalizada a fase de adaptação, as redes serão capazes de, após receber novos padrões, classificá-los, de forma a propiciar, ao operador, informações importantes quanto ao estado de transmissão de barras presentes em um determinado complexo elétrico. Aqui, tomou-se como modelo a simulação de um grande alimentador real, composto por mais de 800 barras. Aliados às RNAs, tam- bém foram aplicadas, no que se refere à análise de dados amostrados de corrente elétri- ca, duas importantes e flexíveis ferramentas matemáticas: a Transformada de Fourier e a Transformada Wavelet. .Observa-se, ao final do trabalho, que os resultados apresenta- dos são bastante encorajadores, o que possibilitaria a utilização do programa em um ambiente real / This work presents a detection and classification of short-circuit faults metho- dology. The main operator of this diagnostic operation is a Fuzzy ARTMAP Artificial Neural Networks (ANN) bank. This tool follows the ANN’s main core: pattern recogni- tion, through an initial supervised training stage, responsible for updating the parame- ters of the networks con-comitant with the desired results. Completed the adaptation phase, the network will be able to, after receiving new standards, classifying them in order to provide to the operator important information about the state of transmission of bars present in a given complex electric. Here, there is, like a model, a simulation of a real big feeder, comprising more than 800 bars. Besides the ANNs, two important and flexible mathematical tools were also applied with regard to the analysis of sampled data of electric current: Fourier Transform and Wavelet Transform. At the end of the work the results presented are very encouraging, which would allow the use of the pro- gram in a no simulations real environment
29

Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = Distributed generators performance during short-circuits considering fault ride-through requirements / Distributed generators performance during short-circuits considering fault ride-through requirements

Silva, Rafael Schincariol da, 1983- 08 March 2012 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T00:53:15Z (GMT). No. of bitstreams: 1 Silva_RafaelSchincariolda_M.pdf: 3440136 bytes, checksum: 042a03fcb6272566cfc1c79d07478e1c (MD5) Previous issue date: 2012 / Resumo: O aumento da penetração de geradores em redes de distribuição de energia elétrica além de diversificar a matriz elétrica proporciona benefícios técnicos e econômicos. Contudo, também levanta preocupações relativas à confiabilidade no suprimento de energia elétrica. Para plantas eólicas conectadas na média e alta tensão são estabelecidos requisitos de "Fault Ride-Through" que determinam que os geradores devem permanecer conectados à rede durante perturbações com afundamentos de tensão e, em alguns casos, fornecer reativos para o reestabelecimento da tensão terminal. Porém, implementar tais requisitos para geradores na baixa tensão não é trivial. Na ocorrência de grandes perturbações os geradores distribuídos devem obrigatoriamente ser desconectados em casos de ilhamento, caso contrário a segurança de pessoas e equipamentos é colocada em risco e a qualidade de energia fornecida não é garantida. Ainda, durante curtos-circuitos os geradores contribuem para ao aumento das correntes de falta e os esquemas de proteção podem sofrer impactos na seletividade e coordenação. Por isso, para atender o requisito de "Fault Ride- Through" seria necessário além de manter os geradores conectados rever os esquemas de proteção de sobrecorrente, sendo necessários estudos dos impactos desta iniciativa e a análise do comportamento dos principais tipos de geradores distribuídos na ocorrência de curtos-circuitos. Nesta dissertação de mestrado, uma rede de distribuição com geradores distribuídos foi analisada através do estudo de sucessivas simulações de transitórios eletromagnéticos. O comportamento de três tipos de geradores distribuídos na ocorrência de curtos-circuitos foi investigado por meio de estudos de estabilidade, da análise das características de afundamentos de tensão e do suporte de reativos. Os geradores síncronos se mostraram com maior capacidade de suportarem faltas temporárias na rede. Os impactos do aumento das correntes de falta nas proteções contra sobrecorrente e da não desconexão do gerador do sistema ilhado também foram analisados. Os resultados mostraram que a presença de geradores distribuídos pode causar problemas na seletividade e na coordenação da proteção, alem de deteriorar o comportamento transitório de geradores ilhados / Abstract: The increase of distributed generation penetration in distribution systems not only helps to diversify the electrical matrix but also brings both technical and economic benefits. Yet, it also raises worries related to energy supply reliability. For wind power plants into the medium and high voltage networks there are the grid codes for "Fault Ride-Through" which stands that wind generators ought to ride a fault with voltage sag and, in some cases, provide reactive power for the terminal voltage restoration. However, implementing such requisites for low voltage connected generators is not a trivial task, as under great perturbations the distributed generators are required to be disconnected from the grid if an islanding situation occurs. Otherwise, people and equipment security would be at risk and the quality of the supplied power cannot be guaranteed. Besides, during short-circuits generators contribute to the increased fault currents along the grid and because of that the protection schemes should experience loss of selectivity and coordination. So, meeting the fault ride-through requirement demand a review of the anti-islanding schemes in order to permit generator islanding, as well as review the protection schemes to guarantee selectivity and coordination. Therefore, studies about the impacts of this initiative are necessary as well as the main generators behavior analysis under short-circuits. In this dissertation, a distribution network was analyzed through successive electromagnetic transient simulations. The behavior of three types of distributed generators under shortcircuits was investigated by stability studies, voltage sag characteristics and reactive power support. Synchronous generators showed to present the best capability to ride through temporary faults on the grid. The impacts on overcurrent protection of increased shortcircuit currents due to the distributed generators and impacts of not disconnecting the generators during islanding situations were also analyzed. The outcomes showed that keeping distributed generators connected might lead to problems on the protection selectivity and coordination and deteriorate the transient behavior of generators / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
30

Comportamento dinâmico e hidrodinâmico de um reator anaeróbico híbrido (UAHB) submetido à variação de carga hidráulica horária no tratamento de esgoto sanitário / Dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) subject to varying hydraulic load rate on the treatment of domestic sewage

Godinho, Jayson Pereira 13 February 2017 (has links)
CAPES / O processo de digestão anaeróbia é muito importante no tratamento dos esgotos sanitários, por ser eficiente, simples e de baixo custo de implantação, operação e manutenção. Embora o Brasil tenha à disposição processos anaeróbios consolidados, o saneamento básico ainda é deficiente no país, e a otimização de reatores anaeróbios tem o intuito de melhorar a viabilidade, efetividade e ampliação dos sistemas de tratamento dos esgotos sanitários. O objetivo deste projeto foi avaliar o desempenho através do comportamento dinâmico e hidrodinâmico de reator anaeróbio híbrido (UAHB), com variação do tempo de detenção hidráulica (TDH) de 4 a 12 h e da DQO (amostras brutas) de 250 a 1250 mgO2L-1. O reator, com volume útil de 22,1 L, foi operado com meio suporte de anéis corrugados de Policloreto de Polivinila (PVC) e mantido a temperatura ambiente, sendo o afluente de alimentação, sintético simulando o esgoto sanitário. Foram analisados os parâmetros físico-químicos: temperatura do líquido e do ar, pH, alcalinidade total (AT), alcalinidade a bicarbonato (AB), ácidos voláteis (AV), demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO520), Turbidez, Sólidos Totais (ST), Sólidos Suspensos Totais (SST), nitrogênio total kjeldahl (N-NTK), nitrogênio amoniacal (Namon), nitrito(N-NO2-), nitrato (N-NO3-) e fósforo total (P). Foi avaliado o comportamento hidrodinâmico e verificada a existência de anomalias hidráulicas, pela técnica de estímulo-resposta tipo pulso com injeção do traçador eosina Y. Ao final dos experimentos, foi realizada a análise estatística para encontrar a condição operacional ótima, bem como os modelos estatísticos para validação dos experimentos. Em todas as condições operacionais foi possível observar que o reator UAHB entrou em equilíbrio dinâmico aparente (EEDA) com produção de alcalinidade para neutralizar os ácidos voláteis produzidos no processo de acidogênese e acetogênese da digestão anaeróbia. O aumento da carga orgânica volumétrica acarretou no aumento das eficiências de remoção em DQO (amostras brutas e filtradas), DBO520 e Turbidez, mas reduziu as remoções de Sólidos Totais e Sólidos Suspensos Totais. A diminuição do TDH reduziu as eficiências de remoção dos parâmetros DQO (amostras brutas e filtradas), DBO520, Sólidos Totais, Sólidos Suspensos Totais e Turbidez. Em relação à hidrodinâmica, em todas as condições operacionais foi observado o efeito de cauda longa, o regime de escoamento no interior do reator UAHB foi classificado como de tanques de mistura completa em série (NCSTR). Foi verificada a presença de zonas mortas no reator, a eficiência hidráulica foi em média 65% para as três condições e não foi possível observar a presença de curtos-circuitos para os três TDH testados. Pela análise estatística do delineamento composto central rotativo (DCCR), a condição ótima de operação para o reator foi para o TDH 12 h e DQO (amostras brutas) 553 mgO2.L-1. / The anaerobic digestion process is very important in the treatment of sewage, as it is an efficient, simple process and low cost of implementation, operation and maintenance. Although Brazil has provided consolidated anaerobic processes, sanitation is still poor in the country, and the optimization of anaerobic reactors aims to improve the viability, effectiveness and expansion of treatment systems for sewage. The aim of this research project is to evaluate the reactor's performance through dynamic and hydrodynamic behavior of hybrid anaerobic reactor (UAHB) with a range of hydraulic retention time (HRT) of 4 to 12 hours and COD (gross samples) 250 - 1250 mgO2L -1. The reactor, with a volume of 22.1 L was operated with support means corrugated rings of Polyvinyl chloride (PVC) and kept at room temperature, the influent feed, simulating the synthetic wastewater. the physicochemical parameters were analyzed: temperature of the liquid and air, pH, total alkalinity (TA), bicarbonate alkalinity (BA), volatile acids (VA), chemical oxygen demand (COD), biochemical oxygen demand (BOD ), Turbidity, Total Solids (TS), total suspended solids (TSS), nitrogen Total Kjeldahl (NTK-N), ammonia nitrogen (amon-N), nitrite (NO2-N), nitrate (NO3-N) and Total phosphorus (P). It evaluated the hydrodynamic behavior and the determination of hydraulic anomalies, the stimulus-response pulse technique with injection of the tracer eosin Y. At the end of the experiments, statistical analysis was performed to find the optimal operating condition as well as the statistical models for validation experiments. In all operating conditions it was observed that the UAHB Reactor became apparent dynamic equilibrium (ADE) with alkalinity production to neutralize the volatile acids produced in acetogenesis process of anaerobic digestion. The increased of organic loading rate resulted in increased efficiencies in the removal of COD (gross and filtered samples), BOD and Turbidity, but reduced removals of Total Solids and Total Suspended Solids. The decrease in HRT reduced the removal efficiencies of COD parameters (grosss and filtered samples), BOD, Total Solids, Total Suspended Solids and Turbidity. Regarding the hydrodynamic in all operating conditions was observed long tail effect, the flow regime inside the reactor UAHB was rated as complete mixing tanks in series (N-CSTR). The presence of dead zones in the reactor was checked, the hydraulic efficiency was averaged 65% for the three conditions and it was not possible to observe the presence of short circuits for the three HRT tested. For the statistical analysis of the central rotary compound design (CRCD), the optimum operating condition for the reactor was to HRT 12 h and COD (gross samples) 553 mgCOD.L-1.

Page generated in 0.0385 seconds