• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 5
  • 1
  • Tagged with
  • 66
  • 14
  • 13
  • 13
  • 12
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Produção estratégica de insumos nucleares para a saúde no Brasil: o caso do FDG-18 F / Health nuclear strategic production in Brazil: FDG-18F case

Élide Mendes Guimarães 03 September 2010 (has links)
No Brasil, a difusão de conceitos da física nuclear na área médica ganhou destaque ao longo da última década com o uso do FDG-18F, substância análoga à glicose marcada radioativamente para atuar em procedimentos de diagnóstico e tratamento em oncologia, neurologia e cardiologia. Das três especialidades é no uso oncológico que estão suas aplicações de maior relevância como a detecção precoce de metástase e outras formas de monitoramento tumoral que resultam em maiores chances de sobrevida ao paciente. Estas possibilidades passaram a fazer parte da realidade nacional com a incorporação da tecnologia híbrida de PET-CT, equipamento gerador de imagens anatômicas e metabólicas para mapeamento preciso de lesões por meio da concentração de FDG-18F. O uso médico deste composto ganhou tamanha repercussão que a necessidade de expandir a oferta de FDG-18F para além dos bolsões geográficos contemplados pela produção pública culminou na aprovação de emenda constitucional que abriu o mercado de radiofármacos no país. O presente estudo aborda a formação da cadeia produtiva de radiofármacos irradiados em cíclotron a partir da quebra do monopólio de produção e comercialização de radioisótopos de meia-vida curta, em 2006, para demonstrar que, ao consolidar a cadeia produtiva de FDG-18F, instituições e atores sociais nela envolvidos constituíram um subsistema nacional de inovação em saúde / In Brazil, nuclear physics concepts become prominent in healthcare throughout the last decade with FDG-18F use, a glucose similar substance radioactively marked to be used in diagnosis and treatment procedures in oncology, neurology and cardiology, but it´s in oncology treatments that we can find the biggest relevance application with the early cancer metastasis detection and many other cancerous tumor monitoring forms that may be revert in patient life time gain. PET-CT hybrid technology incorporation made these possibilities become part of national reality. The equipment is able to produce integrated anatomical and metabolic images that shows tiny tissue damages tracking FDG-18F concentration. This medical composition become renowned enough to claim loud for geographic offer expansion until it raised a new law allowing private initiative taking part in radiopharmaceuticals production market. This research intent to describe the cyclotron radiopharmaceuticals irradiated supply chain building up process since productive and commercial public monopoly broke up in 2006, so then it will be able to prove that a new innovative healthcare subsystem has resulted by the social actors and institutions efforts to establish FDG-18F supply chain
52

Estudo da producao de sup(57)Co e sup(109)Cd em ciclotron

LANDINI, LILIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:00Z (GMT). No. of bitstreams: 1 06867.pdf: 6383508 bytes, checksum: d78bad9ca259bf6a60dc4d98d94fc7a3 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
53

Monitoracao do feixe externo do ciclotron cyclone 30 do IPEN-CNEN/SP

MATSUDA, HYLTON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:46:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:16Z (GMT). No. of bitstreams: 1 07535.pdf: 5658873 bytes, checksum: bfc9a035eb51ae184a489a4570c8c827 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
54

Análise dos níveis de radiação nas dependências dos aceleradores ciclotron do IPEN / Analysis of the radiation levels at the dependences of the accelerator cyclotron of IPEN

SILVA, PAULA P.N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:47Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
55

Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systems

BRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
56

Projeto e implantacao de automacao em sistemas de irradiacao de alvos solidos, liquidos e gasosos em ciclotrons visando a producao de radioisotopos

ARAUJO, SUMAIR G. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:31Z (GMT). No. of bitstreams: 1 07306.pdf: 9914890 bytes, checksum: 6fe7e1a8d060f6bbbccd63db16915245 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
57

Estudo da producao de sup(57)Co e sup(109)Cd em ciclotron

LANDINI, LILIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:00Z (GMT). No. of bitstreams: 1 06867.pdf: 6383508 bytes, checksum: d78bad9ca259bf6a60dc4d98d94fc7a3 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
58

Monitoracao do feixe externo do ciclotron cyclone 30 do IPEN-CNEN/SP

MATSUDA, HYLTON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:46:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:16Z (GMT). No. of bitstreams: 1 07535.pdf: 5658873 bytes, checksum: bfc9a035eb51ae184a489a4570c8c827 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
59

Análise dos níveis de radiação nas dependências dos aceleradores ciclotron do IPEN / Analysis of the radiation levels at the dependences of the accelerator cyclotron of IPEN

SILVA, PAULA P.N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:47Z (GMT). No. of bitstreams: 0 / O objetivo principal deste estudo foi analisar, na Gerência de Aceleradores Cíclotron do IPEN, o controle das doses de radiação ionizante e sua distribuição, comparando seus valores com as exigências regulamentares. A análise do controle das taxas de dose por meio do monitoramento de área foi realizada a partir de dados obtidos durante as produções de Flúor-18 no período de janeiro de 2010 a dezembro de 2011, totalizando 1011 medidas em cada ponto monitorado. A análise das doses provenientes de exposições ocupacionais foi realizada por meio de consulta aos históricos de dose individual. Durante os anos de 2007 a 2011 foram analisados os registros individuais das doses efetivas, totalizando 91 registros e de 2009 a 2011 foram analisados os registros de dose equivalente (nas mãos), totalizando 49 registros. Os indivíduos ocupacionalmente expostos envolvidos no estudo foram classificados, de acordo com a tarefa, em três grupos: alvos, radioproteção e operação e manutenção. Os resultados obtidos dos níveis de exposição ocupacional da radiação foram analisados e comparados com os limites estabelecidos pela autoridade regulatória nacional e com as recomendações internacionais. Com base nos resultados registrados do monitoramento de área e das doses recebidas, os procedimentos de radioproteção aplicados na instalação durante o período estudado foram averiguados e sugestões de melhorias foram dadas sob o ponto de vista da proteção radiológica. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
60

Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systems

BRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta os métodos de padronização de 111In e 99mTc, em sistemas de coincidências 4πβ-γ. O 111In foi produzido em cíclotron pela reação 111Cd(p, n)111In; decai com uma meia vida de 2,8 dias pelo processo de captura eletrônica populando os níveis excitados do 111Cd, emitindo raios gama de 171 keV e 245 keV. O 99mTc decai com uma meia vida de 6,007 h por transição isomérica do decaimento radioativo do 99Mo . A padronização do 111In foi feita no sistema 4πβ-γ constituído de um detector proporcional em geometria 4π acoplado a dois cristais cintiladores de NaI(Tl) com eletrônica convencional. A radiação gama selecionada para medida em coincidência foi de (171 + 245) keV. A escolha da janela gama foi baseada na análise da previsão da curva de extrapolação obtida na simulação de Monte Carlo. A padronização do 99mTc foi feita num sistema 4πβ-γ usando um contador proporcional de janela fina acoplado a um cristal de cintilação NaI (Tl). A eficiência beta foi variada por discriminação eletrônica, usando sistema de coincidências por software (SCS). A padronização do 99mTc foi feita pela seleção de dois intervalos gama, um no pico de absorção total de 140 keV e outro no pico de absorção total dos raios X de 20 keV. O resultado da atividade experimental de duas soluções de 111In concorda com o resultado obtido pela simulação de Monte Carlo. As atividades experimentais do 99mTc para os dois intervalos gama selecionados estão de acordo dentro da incerteza experimental, indicando que a metodologia adotada é adequada. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1268 seconds