• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Elaboration de films catalytiques co-alumine par dépôt électrophorétique pour l'hydrolyse du NaBH4 : développement du procédé dans une perspective de valorisation d'argiles naturelles du Liban comme supports de catalyseurs / Elaboration of catalytic films coblat-alumina by electrophoretic deposition for hydrolysis of NABH4 : developpement of this procedure for the valorization of natural clays from Lebanon as catalysys supports

Chamoun, Rita 29 September 2010 (has links)
L’hydrolyse spontanée du NaBH4 en milieu aqueux est une réaction lente nécessitant l’emploi d’un catalyseur pour l’accélérer. Nous présentons ici l’élaboration de catalyseurs Co supporté sur αAl2O3 mis forme de films, plus appropriés pour des applications nécessitant un démarrage/arrêt à la demande de la génération d’H2. Les films sont déposés sur un substrat Cu par dépôt électrophorétique (DEP). Par ailleurs, des catalyseurs Co supporté sur différentes argiles naturelles (Kaolinite, Illite-A et Illite-B) en provenance du Liban ont été élaborés. Le Co a été déposé sur αAl2O3 par six voies différentes : 1. Imprégnation de Co sur film αAl2O3 ; 2. Précipitation de Co sur film αAl2O3; 3. Electrodéposition du Co sur film αAl2O3; 4. Codéposition du Co et de αAl2O3; 5. Codéposition de nanoparticules de Co et de αAl2O3 et 6. DEP de Co-αAl2O3. La voie 6 est la meilleure pour l’élaboration des films 1, 5, 10 et 15 mass.% Co-αAl2O3. Ces films (homogènes) et les catalyseurs Co-αAl2O3 ont été comparés pour leur réactivité et l’étude cinétique a donné des énergies apparentes d’activation identiques: 51.3 et 52.7 kJ mol-1, respectivement.Ensuite, des catalyseurs de 1, 5, 10 et 15 mass.% Co-argile ont été élaborés selon le même procédé que celui de Co-αAl2O3. Ces catalyseurs ont montré une réactivité pour l’hydrolyse du NaBH4, donnant notamment des énergies apparentes d’activation de 58.8, 51.5 et 58.1 kJ mol-1 pour 15 mass.% Co-Kaolinite, (Illite-A) et (Illite-B) respectivement. De plus, des films homogènes de 1, 5, 10 et 15 mass.% Co-Kaolinite ont été déposés avec succès sur Inox par DEP. Cette étude a montré le potentiel de ces argiles naturelles comme supports de catalyseur / NaBH4 hydrolysis reaction is slow in aqueous medium. Therefore, it can be accelerated by addition of a catalyst. In this work, catalytic films of Co supported over αAl2O3 have been synthesized since they are more convenient for applications requiring generation of H2 on demand. Co-αAl2O3 films were deposited on Cu plates by electrophoretic deposition method (EPD). Furthermore, catalysts of Co supported over different types of natural clay (Kaolinite, Illite-A and Illite-B) provided from Lebanon were also synthesized.Co was deposited over αAl2O3 following six routes: 1. αAl2O3 film impregnation; 2. Co precipitation over αAl2O3 film; 3. Co electrodeposition over αAl2O3 film; 4. Coelectrodeposition of Co from CoCl2 and αAl2O3; 5. Coelectrodeposition of Co nanoparticles and αAl2O3 and 6. EPD of Co-αAl2O3. Route 6 was found to be the best one for the fabrication of homogeneous films of 1, 5, 10 and 15 wt.% Co-αAl2O3. A comparative study on the reactivity of Co-αAl2O3 films and powder catalysts was done and the kinetic study gave similar values of the apparent activation energies: 51.3 and 52.7 kJ mol-1, respectively. Moreover, Co was supported over clay with the same method used for Co-αAl2O3. 1, 5, 10 and 15 wt.% Co-clay catalysts were tested for the hydrolysis reaction and the apparent activation energies obtained were as follows: 58.8, 51.5 and 58.1 kJ mol-1 for 15 wt.% Co-Kaolinite, (Illite-A) and (Illite-B) respectively. Homogeneous films of 1, 5, 10 and 15 wt.% Co-Kaolinite were successfully deposited over Inox substrate by EPD. It was concluded from this work that natural clays can be used as potential supports for Co catalysts in the hydrolysis of NaBH4
2

Microsystème pour la nanomédecine : application aux maladies nosocomiales et à la détection des agents pathogènes / Microsystem for Nanomedicine : Application to nosocomial diseases and detection of pathogens

Kahlouche, Karima 19 December 2018 (has links)
Ce travail a pour objet l’étude et le développement d’un capteur électrochimique pour la détection sélective quantitative des analytes biologiques à l’échelle nano. Il se divise en deux parties après une présentation de l’état de l’art sur les maladies nosocomiales et les capteurs électrochimiques. Tout d’abord, nous avons développé un protocole spécifique qui repose sur la fonctionnalisation localisée de la microélectrode de travail par dépôt électrophorétique d'oxyde de graphène réduit/polyéthylènimine (rGO/PEI) pour amplifier le signal de détection. Le microsystème réalisé en salle blanche, a été exploité avec succès pour la détection sélective de la dopamine avec une limite de détection de 50 nM.Ensuite, nous avons utilisé la même plateforme constituée d’électrodes de plus grande taille (mm) pour la réalisation d’un capteur immunologique. Il a démontré son efficacité, de manière spécifique et sélective, pour discriminer la souche sauvage E. Coli UTI89 de UTI89 Δfim (sans opéron), avec une limite de détection de 10 cfu mL−1. En outre, le concept d’utilisation d’une électrode modifiée par rGO/PEI par la modification covalente avec des anticorps pathogènes est général. Il peut être facilement adapté à toute autre espèce pathogène, rendant l’approche générique. Le capteur a donc abouti à des résultats intéressants en milieu aqueux, sérique et urinaire, ce qui est essentiel pour son utilisation potentielle pour le diagnostic clinique des maladies pathogènes. / The purpose of this work concerns the study and development of an electrochemical sensor for both quantitative and selective detection of biological analytes at the nanoscale. It is divided into two parts after a presentation of the state of the art on nosocomial diseases and electrochemical sensors. First, we have developed a specific protocol based on the localized functionalization of the working microelectrode by electrophoretic deposition. The strategy is based on the localizedfunctionalization of the working microelectrode by electrophoretic deposition of reduced graphène oxide / polyethyleneimine (rGO / PEI) to amplify the detection signal. The microsystem built in a clean room has been successfully tested for the selective detection of dopamine with a detection limit of 50 nM. In addition, the microsystem showed good performance in detecting dopamine levels.Then, we have also used the same electrode platform at a larger scale (mm) for the specific and selective detection of the immunological sensor which has demonstrated its effectiveness in distinguishing the UTI89 E. Coli wild-type strain of UTI89 Δfim (without operon), with a detection limit of 10. cfu mL-1. In addition, the concept of rGO / PEI modified electrode by covalent modification with pathogenic antibodies is general and can be easily transposed to any other pathogenic species, making the approach very versatile and generic.The sensor works in aqueous, serum and urinary media, which is essential for its potential use in clinical diagnosis of pathogenic diseases.
3

Bio-encapsulation d'oxydases et de déshydrogénases par électrogénération sol-gel sur réseau de nano-objets / Bioencapsulation of oxidases and dehydrogenases using electrochemically-assisted sol-gel deposition on the nanoobjects network

Mazurenko, Ievgen 03 June 2013 (has links)
Dans cette thèse, des travaux de recherche ont été menés pour immobiliser différentes enzymes (oxydases et déshydrogénases) au sein d'une matrice de silice dans le but de construire un biocapteur ampérométrique. Des matériaux nanostructurés ont ensuite été introduit dans ce système afin d'améliorer les caractéristiques analytiques de ces biocapteurs. La méthode de dépôt sol-gel par assistance électrochimique a été choisie pour l'immobilisation des enzymes à la surface des électrodes et des nanomatériaux car elle donne la possibilité de contrôler finement l'épaisseur du film déposé afin de couvrir individuellement ces objets. La faisabilité de cette approche a été montrée par la modification de nanofibres de platine présentant une grande surface active pour l'oxydation de H2O2 produit en présence de biocomposite silice-glucose oxidase. Le dépôt sol-gel électrochimiquement assisté permet également la modification d'électrodes imprimées en or par un biocomposite silice-choline oxidase, ce qui donne la possibilité de construire rapidement un biocapteur à choline présentant de très bonnes caractéristiques analytiques. Les nanotubes de carbone ont également été choisis comme matrice pour l'immobilisation de déshydrogénases car ils permettent d'obtenir une grande aire spécifique et des propriétés catalytiques intéressantes pour l'oxydation du co-facteur enzymatique NADH. La méthode de dépôt électrophorétique a été utilisée pour créer des couches de nanotubes poreuses ayant une épaisseur contrôlée à la surface d'un support de carbone vitreux. Les électrodes ainsi préparées présentent de bonne performances électrochimiques, permettant notamment de déplacer le potentiel d'oxydation de NADH et d'augmenter la sensibilité de détection. Un biocomposite silice-sorbitol déshydrogénase a ensuite été déposé à la surface de la couche de nanotubes de carbone en utilisant la méthode de dépôt sol-gel assisté par électrochimie pour construire un biocapteur à sorbitol. La méthode de dépôt électrophorétique a enfin été appliquée pour la première fois à l'élaboration d'assemblages de nanotubes de carbone macroporeux. De tells assemblages ont été utilisés comme support pour co-immobiliser la sorbitol déshydrogénase et le co-facteur enzymatique au sein des macropores, ce qui a permis d'augmenter la sensibilité de la détection du sorbitol par comparaison avec un assemblage de nanotubes de carbone non macroporeux / In this thesis, the research work was focused on the immobilization of different enzymes (oxidases and dehydrogenases) into biocomposite silica matrix with the aim of amperometric biosensors construction. Then, the structured nanomaterials were introduced in the system in order to improve the characteristics of biosensors. The method of electrochemically-assisted deposition was chosen for the immobilization of enzymes on the surface of nanomaterials as it provides possibility of fine tuning of film thickness allowing covering each individual nanoobject. The feasibility of this was shown while modifying the platinum nanofibers, which demonstrate high electroactive surface and H2O2 oxidation rate, with silica-glucose oxidase biocomposite. The electrochemically-assisted deposition also allows the express modification of gold screen-printed electrodes with silica-choline oxidase biocomposite making possible the quick fabrication of cheap choline biosensors with high analytical characteristics. The carbon nanotubes was chosen as matrix for the immobilization of dehydrogenases as they have high surface area and electrocatalytic properties towards the oxidation of enzymatic co-factor NADH. The method of electrophoretic deposition was used for the creation of porous CNT-layer with controllable thickness on the surface of glassy carbon electrode. Created thereby matrix demonstrated good electrochemical performance significantly shifting the potential and increasing sensitivity of NADH oxidation. Then the biocomposite silica-sorbitol dehydrogenase film was deposited on the CNT-layer by means of electrochemically-assisted deposition for the construction of high-performance sorbitol biosensor. The method of electrophoretic deposition was also applied for the first time for the construction of thick macroporous CNT-assemblies with uniform pore size using template approach. Such macroporous CNT-electrode was used for the co-immobilization of sorbitol dehydrogenase and enzymatic co-factor inside the pores demonstrating higher sensitivity of sorbitol detection in comparison with nonporous CNT-electrode

Page generated in 0.0837 seconds