• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Imagerie SPR optimisée en résolution pour l'étude et la détection de bactéries / Resolution optimized SPR imaging for the study and detection of bacteria

Boulade, Marine 18 April 2019 (has links)
L’étude, la détection et l’identification de pathogènes est une problématique majeure pour la sécurité alimentaire et la médecine. Cependant, les pathogènes bactériens présents à de faibles concentrations nécessitent souvent une période de plus de 36h pour être identifiés par les méthodes standards. Ce délai est extrêmement contraignant pour des domaines où la rapidité du diagnostic est un facteur clé. Il y a donc une forte demande pour le développement d’outils pour mieux comprendre le comportement bactérien et ainsi développer des techniques de détection plus rapides et plus performantes.Les systèmes d’imagerie SPR sont largement utilisés pour l’analyse d’interactions moléculaires, car ils permettent une mesure en parallèle, en temps réel et sans marquage, tout en étant faciles d’utilisation et compatibles avec des milieux complexes. Cette technique a montré son efficacité pour l'étude et la détection de bactéries en utilisant les interactions moléculaires avec les anticorps, mais les délais de détection restent pénalisants.Dans ce contexte, un nouveau système d’imagerie permettant l’étude et la détection spécifique de pathogènes bactériens performant est développé en mettant à profit les avancées récentes en imagerie SPR optimisée en résolution. Notre système permet d'améliorer les temps de détection de pathogènes en milieux modèles grâce à sa capacité à détecter des bactéries individuelles. Il peut également être utilisé pour l'étude de l'interaction entre bactéries et surfaces spécifiques. Des premiers tests montrent que notre instrument est capable de caractériser le comportement bactérien de plusieurs souches bactériennes en interaction avec des surfaces fonctionnalisées par des espèces chimiques différentes / The study, detection and identification of pathogens is a major issue for food safety and medicine. However, bacterial pathogens present at low concentrations often require a period of more than 36 hours to be identified by standard methods. This delay is extremely constraining for areas where rapid diagnosis is a key factor. There is therefore a strong demand for the development of tools to better understand bacterial behavior and thus develop faster and more efficient detection techniques.SPR imaging systems are widely used for the analysis of molecular interactions, as they allow parallel, real-time and unlabeled measurement, while being easy to use and compatible with complex media. This technique has proven effective in the study and detection of bacteria using molecular interactions with antibodies, but detection times remain penalizing.In this context, a new imaging system allowing the study and specific detection of high-performance bacterial pathogens is being developed, taking advantage of recent advances in SPR imaging optimized in resolution. Our system improves pathogen detection times in model environments through its ability to detect individual bacteria. It can also be used to study the interaction between bacteria and specific surfaces. Initial tests show that our instrument is capable of characterizing the bacterial behaviour of several bacterial strains in interaction with surfaces functionalized by different chemical species.
2

Electromagnetic microsystem for the detection of magnetic nanoparticles in a microfluidic structure for immunoassays / Système électromagnétique de détection de nanoparticules magnétiques dans une structure microfluidique pour l'immunodétection

Rabehi, Amine 30 January 2018 (has links)
La détection et quantification d’agent biologique occupe une place prépondérante dans la prévention et la détection des dangers possibles pour la santé publique (épidémie ou pandémie), l’environnement ainsi que d’autres risques contextuelles (bioterrorisme, armes biologique ou chimiques…etc.). Par conséquent, le développement d’un système portable et à moindre coût permettant de détecter ces dangers constitue l’axe de recherche pluridisciplinaire de la collaboration entre différents laboratoires de l’UPMC (Paris 6) et « RWTH university » à Aachen en Allemagne. Dans ce projet, nous avons étudié les aspects pluridisciplinaires d’un microsystème (LoC) électromagnétique de détection immunologique basé sur l’utilisation de nanoparticules magnétiques (MNP). En raison de leur extractabilité et de leur triabilité, les MNP sont adaptées à l'examen d'échantillons biologiques, servant de marqueurs pour des réactions biochimiques. La plupart des techniques classiques de détection existantes sont basées sur des méthodes colorimétrique, fluorescence ou électrochimique qui souffrent en majorité de problème de temps d’analyse et de sensibilité. A cet égard, Les méthodes d’immuno-détection magnétiques constituent une alternative prometteuse. Cette détection est effectuée à l’aide des MNP qui sont spécifiquement bio-fonctionnalisés en surface afin d’être liée à la cible (virus, anticorps…etc). La nouvelle méthode magnétique de mélange de fréquence permet la détection et la quantification de ces MNP avec une grande dynamique. Dans cette thèse, l’effort est dirigé vers la miniaturisation de ce système. Pour ce faire, nous avons développé un ensemble d’outils analytiques et de simulations multiphysiques afin d’optimiser les dimensions des parties électromagnétique (bobines planaires) et microfluidiques. Par la suite, des prototypes de cette structure de détection à partir de bobines en circuits imprimés et de réservoirs microfluidiques en PDMS sont dimensionnés et réalisés. Les performances de ces prototypes ont été évaluées en termes de limite de détection de MNP, linéarité et plage dynamique. En outre, ces prototypes ont permis de valider les outils de dimensionnement réalisés. Une limite de détection de nanoparticules magnétiques de 15ng/mL a été mesurée avec un volume d'échantillon de 14 μL correspondant à une goutte de sang. Finalement, la validation du système quant à l’immuno-détection est abordée avec un état de l’art et le développement d’une procédure de fonctionnalisation biochimique de surface ainsi que des premiers tests pour sa validation. / The detection and quantification of a biological agent or entity has become paramount to anticipate a possible health threat (epidemic or pandemic), environmental threat or to combat other contextual threats (bioterrorism, chemical and biological weapons, drugs). Consequently, developing a portable cost effective device that could detect and quantify such threats is the research focus of the joint multidisciplinary project between UPMC (Paris 6) laboratories and RWTH university in Aachen, Germany. In the framework of this project, we have studied the multidisciplinary aspects of an electromagnetic microsystem for immunologic detection based on magnetic nanoparticles (MNP) in a microfluidic lab-on-chip (LoC). Because of their extractability and sortability, magnetic nanoparticles are adapted for examination of biological samples, serving as markers for biochemical reactions. So far, the final detection step is mostly achieved by well-known immunochemical or fluorescence-based techniques which are time consuming and have limited sensitivity. Therefore, magnetic immunoassays detecting the analyte by means of magnetic markers constitute a promising alternative. MNP covered with biocompatible surface coating can be specifically bound to analytes, cells, viruses or bacteria. They can also be used for separation and concentration enhancement. The novel frequency mixing magnetic detection method allows quantifying magnetic nanoparticles with a very large dynamic measurement range. In this thesis, emphasis is put on the miniaturized implementation of this detection scheme. Following the development of analytical and multiphysics simulations tools for optimization of both excitation frequencies and detection planar coils, first multilayered printed circuit board prototypes integrating all three different coils along with an adapted microfluidic chip has been designed and realized. These prototypes have been tested and characterized with respect to their performance for limit of detection (LOD) of MNP, linear response and validation of theoretical concepts. Using the frequency mixing magnetic detection technique, a LOD of 15ng/mL for 20 nm core sized MNP has been achieved with a sample volume of 14 μL corresponding to a drop of blood. Preliminary works for biosensing have also been achieved with a state of the art of surface functionalization and a developed proposed biochemical immobilization procedure and preliminary tests of its validation.
3

Détection à large spectre de pathogènes bactériens à l'aide de peptides antimicrobiens / Wide-spectrum biosensors based on antimicrobial peptides for the detection of pathogenic bacteria

Pardoux, Éric 25 October 2019 (has links)
L’analyse microbiologique pour confirmer l’absence de bactéries dans des échantillons biologiques normalement sains, comme le sang, est une routine dans de nombreux laboratoires. En effet, la présence de bactéries dans le sang, appelée bactériémie, peut avoir des conséquences très graves, voire mortelles pour le patient. Le protocole standard pour la détection des bactériémies repose jusqu’ici sur l’enrichissement des échantillons sanguins prélevés sur les patients lors de l’hémoculture, afin d’obtenir une population suffisante pour analyse. La lenteur de ce procédé retarde ainsi de parfois plusieurs jours le diagnostic et donc l’adaptation du traitement antibiotique administré au patient. Ces dernières décennies, des techniques comme l’identification par spectrométrie de masse ou les analyses moléculaires, ont permis de diminuer le délai requis pour identifier les pathogènes en cause. Dans ce contexte, l’emploi de biocapteurs est également une alternative. Ce travail propose d’inclure des sondes à large spectre dans un capteur optique par imagerie SPR (résonance de plasmons de surface). Ce système est déjà développé pour la reconnaissance spécifique de pathogènes au cours de leur croissance dans le sang. Les nouveaux ligands proposés et évalués sont les peptides antimicrobiens (PAM). Ces courts peptides cationiques et amphiphiles, présentent l’avantage d’un large spectre d’interaction couplé à une haute stabilité (chimique, thermique et séchage) comparativement aux anticorps employés jusqu’ici. Leur immobilisation sur des prismes SPRI permet d’évaluer simultanément l’affinité de plusieurs PAM à la même souche bactérienne. Les biocapteurs ainsi préparés ont permis de détecter des souches pathogènes d’Escherichia coli et Staphylococcus aureus en milieu de culture simple, comme en plasma et en sang dilué au milieu d’hémoculture. Le système obtenu permet la détection des pathogènes présents à une concentration initiale de l’ordre de 1 UFC.ml-1, en moins de 24 heures et quel que soit le milieu. Enfin, la mise en place d’analyses statistiques multidimensionnelles a abouti à une classification cohérente des espèces ciblées en milieu simple, comme en sang. Ces résultats montrent le potentiel de ce système pour parvenir à développer un biocapteur à large spectre capable à la fois de détecter mais aussi d’identifier par affinité croisée des pathogènes bactériens. / Microbiological analysis to confirm the absence of bacteria in normally sterile biological samples, such as blood, is routine in many laboratories. The presence of bacteria in blood, called bacteremia, can have very serious, and even fatal consequences for the patient. So far, the standard protocol for their detection has been based on the enrichment of blood samples collected from patients, thanks to blood culture, in order to obtain a sufficient population for analysis. These procedures are time consuming which sometimes lead to delays in diagnosis and subsequent adaptation of antibiotic treatments by several days. In recent decades, techniques such as mass spectrometry identification or molecular analyses have reduced the time required to identify the pathogens involved. In this context, the use of biosensors is another promising alternative. This work proposes to include wide spectrum probes in an optical sensor using SPR imaging (surface plasmon resonance). This system is already developed for the specific recognition of pathogens during their growth in the blood. The new ligands we propose to evaluate are antimicrobial peptides (AMP). These short, cationic and amphiphilic peptides have the advantage of having a broad spectrum of interaction with bacteria, coupled with high stability (chemical, thermal and drying), especially compared to the antibodies used so far in this technique. Their immobilization on SPRI prisms allows the simultaneous evaluation of the affinity of several AMP to the same bacterial strain. The biosensors based on AMP were able to detect pathogenic strains of Escherichia coli and Staphylococcus aureus in simple culture medium, such as plasma and diluted blood in blood culture medium. The system obtained allows the detection of pathogens present at an initial concentration of about 1 CFU.ml-1, in less than 24 hours and in all assayed media. Finally, the implementation of multidimensional statistical analyses has resulted in a consistent classification of targeted species, in simple culture medium, such as blood. These results show the potential of this system to develop a wide-spectrum biosensor capable of both detecting and cross-referencing bacterial pathogens.

Page generated in 0.0891 seconds