• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 8
  • 7
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 58
  • 12
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo do calor específico de compostos Heusler paramagnéticos, da série do níquel Ni 2 Tal, onde T=Ti, Zr, Hf, V, Nb e Ta

Rocha, Fabio Saraiva da January 1997 (has links)
Neste trabalho apresentamos os resultados experimentais da medida do calor específico dos compostos Heusler da série Ni2TA1, onde T =Ti, Zr,Hf,V,Nb, Ta. Estas medidas foram feitas utilizando-se um calorímetro adiabático que atua na faixa de 1,84 K a 10,3 K e visaram o estudo da estrutura elêtrônica dos compostos em termos da densidade de estados eletrônicos à nível de Fermi, bem como da dinâmica da rede cristalina, com o uso dos modelos de Debye e de Einstein para o calor específico. Apresentamos, também, uma descrição do calorímetro, seu funcionamento e as alterações ocorridas em função deste trabalho.
32

Estudo do calor específico de compostos Heusler paramagnéticos, da série do níquel Ni 2 Tal, onde T=Ti, Zr, Hf, V, Nb e Ta

Rocha, Fabio Saraiva da January 1997 (has links)
Neste trabalho apresentamos os resultados experimentais da medida do calor específico dos compostos Heusler da série Ni2TA1, onde T =Ti, Zr,Hf,V,Nb, Ta. Estas medidas foram feitas utilizando-se um calorímetro adiabático que atua na faixa de 1,84 K a 10,3 K e visaram o estudo da estrutura elêtrônica dos compostos em termos da densidade de estados eletrônicos à nível de Fermi, bem como da dinâmica da rede cristalina, com o uso dos modelos de Debye e de Einstein para o calor específico. Apresentamos, também, uma descrição do calorímetro, seu funcionamento e as alterações ocorridas em função deste trabalho.
33

Huygens subgridding for the frequency-dependent/finite-difference time-domain method

Abalenkovs, Maksims January 2011 (has links)
Computer simulation of electromagnetic behaviour of a device is a common practice in modern engineering. Maxwell's equations are solved on a computer with help of numerical methods. Contemporary devices constantly grow in size and complexity. Therefore, new numerical methods should be highly efficient. Many industrial and research applications of numerical methods need to account for the frequency dependent materials. The Finite-Difference Time-Domain (FDTD) method is one of the most widely adopted algorithms for the numerical solution of Maxwell's equations. A major drawback of the FDTD method is the interdependence of the spatial and temporal discretisation steps, known as the Courant-Friedrichs-Lewy (CFL) stability criterion. Due to the CFL condition the simulation of a large object with delicate geometry will require a high spatio-temporal resolution everywhere in the FDTD grid. Application of subgridding increases the efficiency of the FDTD method. Subgridding decomposes the simulation domain into several subdomains with different spatio-temporal resolutions. The research project described in this dissertation uses the Huygens Subgridding (HSG) method. The frequency dependence is included with the Auxiliary Differential Equation (ADE) approach based on the one-pole Debye relaxation model. The main contributions of this work are (i) extension of the one-dimensional (1D) frequency-dependent HSG method to three dimensions (3D), (ii) implementation of the frequency-dependent HSG method, termed the dispersive HSG, in Fortran 90, (iii) implementation of the radio environment setting from the PGM-files, (iv) simulation of the electromagnetic wave propagating from the defibrillator through the human torso and (v) analysis of the computational requirements of the dispersive HSG program.
34

SOFT POLYELECTROLYTE HYDROGEL AS VERSATILE MATERIAL IN DIFFERENT APPLICATION

WANG, YUJEN 13 September 2016 (has links)
No description available.
35

Modélisation des couches minces électriques dans les bio-microsystèmes

De Vroey, Laurent 13 February 2008 (has links)
L'utilisation de systèmes électromécaniques microstructurés pour analyser et manipuler des solutions biologiques ou des cellules vivantes (bio-MEMS) a pris un essor considérable ces dernières années. Dans ce genre de dispositifs, l'utilisation de champs électriques est fréquente, que ce soit pour percer les membranes des cellules et effectuer une transfection de gènes par exemple (électroporation), pour les déplacer ((di )électrophorèse) ou agir sur le milieu dans lequel elles baignent (électro-hydrodynamique). La modélisation des phénomènes induits par ces champs électriques dans les solutions aqueuses est un problème multi-physique et multi-échelle. Au déplacement des électrons s'ajoute en effet la migration des ions présents dans la solution. Ceux-ci se concentrent en particulier aux abords des électrodes formant des couches minces dont les paramètres évoluent de façon encore mal connue en fonction notamment des conditions d'alimentation. La thèse se concentre sur les applications électro-hydrodynamiques dans lesquelles une solution saline est mise en mouvement par des forces électriques agissant sur ses ions, concentrés dans des couches de charges minces, au voisinage des électrodes. Sont d'abord présentés les résultats expérimentaux et des modèles simples du problème électromécanique dans le cas de structures 2D à électrodes coplanaires. Devant l’importance des écarts entre les résultats théoriques et expérimentaux, des modèles plus complets sont alors proposés et évalués. Malgré les améliorations fournies par ces modèles, des écarts importants subsistent entre théorie et expérimentation, et une étude totalement découplée des aspects électriques et mécaniques est alors réalisée sur une structure 1D. Cette étude permet de mieux cerner les dépendances de certains paramètres physiques vis-à-vis des conditions d’alimentation avec une comparaison systématique des résultats expérimentaux et des résultats de modèles circuits linéaires et non linéaires, au travers d’une approche fréquentielle par diagrammes de Bode et d’une approche temporelle par figures de Lissajous. Il a ainsi pu être mis en évidence l’importance pratique potentielle de certains phénomènes rarement pris en compte dans des modèles globaux : saturation des couches minces, permittivité non constante, effets de bords,… Des applications pratiques ont pu être dégagées et testées expérimentalement, dans le domaine des micro-mélangeurs. Outre ces développements, une brève étude est décrite, portant sur la modélisation des cellules et de leurs membranes extrêmement fines en regard des autres dimensions caractéristiques du système, dans la perspective par exemple d'applications en électroporation. Une autre étude est faite portant sur l’utilisation potentielle de méthodes numériques dites « sans maillage » pour ce type d’applications, l’accent étant mis sur la résolution du problème de Poisson dans des systèmes 2D. / Analysis and manipulation of biological solutions or cells in micro-electromechanical systems has considerably improved during last years. In such systems, it is common to use electric fields, in order e.g. to increase cells membrane porosity, which is known as electroporation, and thus allow for gene transfection. Electric fields can also generate the motion of cells in a solution by (di-)electrophoresis effects or induce the movement of the solution itself, through electro-hydrodynamic effects. Finding theoretical models for those phenomena requires a multi-physic and multi-scale approach. The ions present in the saline solution react mechanically to the electrical excitation of the system. They migrate to the regions close to the electrodes, in very thin layers whose parameters vary in non-obvious ways, depending namely on the power supply conditions. The text focuses on electro-hydrodynamic applications in which a flow is generated by electric forces acting on the ions present in the solution, mostly in thin charge layers near the electrodes. Experimental results and simple existing models are first presented for 2D coplanar electrodes systems. Regarding the important differences between models and experimentation, more complete models are then proposed and tested. In spite of the improvements of those new models, some important differences remain, so that a fully decoupled approach of electrical and mechanical aspects is needed, which is pursued on a 1D structure. This new study allows for a better understanding of the dependences of some physical parameters with regard to supply conditions, with a systematic comparison of experimental results and non-linear circuit models results. A frequency approach with Bode diagrams is used, as well as a time approach with Lissajous figures. It has been shown that some phenomena are of practical and fundamental importance, which are not always taken into account in more general and global models : saturation phenomena, non constant physical parameters, border effects,… Practical applications have been deduced and tested experimentally, in the case of micro-mixing. A brief study is also mentioned, concerning the modeling of cells with extremely thin membranes compared to the other characteristic dimensions of the system, in the perspective e.g. of electroporation applications. Another short study is performed about the potential use of « meshless » numerical methods for the solving of this kind of applications, focusing more specifically on the solving of a Poisson problem in 2D.
36

Solubility Modelling in Condensed Matter. Dielectric Continuum Theory and Nonlinear Response

Sandberg, Lars January 2002 (has links)
No description available.
37

Solubility Modelling in Condensed Matter. Dielectric Continuum Theory and Nonlinear Response

Sandberg, Lars January 2002 (has links)
No description available.
38

The Non-uniform Argon Dc Glow Discharge System Parameters Measured With Fast Three Couples Of Double Probe

Akbar, Demiral Salih 01 March 2006 (has links) (PDF)
The non-uniform dc glow discharge plasma system is studied by using isolated computer controlled three couples of double probe system (TCDP) in argon gas, simultaneously. TCDP system has been developed to use for magnetized, unmagnetized, and for low oscillating plasma systems by using low pass filter with optically isolated circuitry to minimize the measurement errors with higher resolution and accuracy. Difference in the shapes and diameters of the discharge tube from region to region leads to change in the positive column glow discharge properties. This is because the positive column inhomogeneities, rising from the increase in the electron densities at the small tube radius region than the large one. Therefore, the axial electric field and the electron temperature have been diverted from their normal behavior in the positive column. However, at the large radius regions, the axial electric field seams to stay approximately constant at higher discharge currents. On the other hand, In this work the radial dependence of the electron temperature, density, floating potential, and the normalized probe radius (&amp / #958 / =rp&amp / #955 / D) has been investigated. Since, the probe radius is smaller than Debye length, the orbital motion limited (OML) theory has been used. As a result, the electron temperature (at the center) decreased and density increased with decreasing tube radius, and they have maximum values at the first probe (near the cathode). The electron density ne was observed to decrease and electron temperature Te to increase with increasing the discharge current. The floating potential has less negative value with decreasing tube radius except at the higher currents. Finally, it has been found that the &amp / #958 / is proportional with electron density, but it remains constant depending on the value of Te and ne.
39

Contrôle et suivi des propriétés visco-élastiques d'un composite en cours de fabrication / Control and monitoring of viscoelastic properties of a composite during manufacturing

Ghodhbani, Nacef 19 May 2016 (has links)
Les transducteurs ultrasonores font l'objet de nombreux développements en contrôle non-destructif (CND) industriel. Utilisé ponctuellement et périodiquement, le CND ultrasonore permet d'établir des diagnostics sur la santé des matériaux. La caractérisation ultrasonore en temps réel constitue un outil de surveillance de l'évolution des propriétés physiques lors de la fabrication des matériaux composites. Dans ce contexte, des études sont menées au LOMC pour optimiser le procédé de fabrication des matériaux composites par RTM (Resin Transfer Molding) afin d’améliorer la qualité du produit. Ce travail de thèse consiste à développer des méthodes ultrasonores pour le suivi des propriétés viscoélastiques d’un composite pendant la phase de production. Les propriétés viscoélastiques sont étudiées à l’aide de modèles théoriques, de simulations numériques et de résultats expérimentaux. Des études de calibration ont été menées afin d’étudier les facteurs d’influence sur le suivi de propriétés ultrasonores lors de la mise en oeuvre d’un procédé RTM. Le suivi des paramètres viscoélastiques de résines époxy est effectué dans un premier temps à basse température au cours d'une polymérisation isotherme et d’une post-cuisson. Ensuite, une approche basée sur la méthode de caractérisation en émission/transmission a été développée afin d’étudier le comportement à haute température. La modélisation de la réponse électroacoustique par série de Debye (DSM) a été effectuée en se basant sur des approches analytiques. L’utilisation des transducteurs multiéléments permet la localisation et le dimensionnement de défauts lors du déplacement de fibres de carbone dans une résine liquide, entre des moules. / The developments based on ultrasonic transducers are nowadays numerous in the industrial non-destructive testing (NDT). Used punctually and periodically, the ultrasonic NDT is used for health diagnostics of materials. Ultrasonic characterization in real time allows a physical properties monitoring during the manufacturing of composite materials. In this context, studies are conducted in LOMC in view to optimize the manufacturing process of composite materials using RTM (Resin Transfer Molding) in order to improve the product quality. This work consists to develop ultrasonic methods for the monitoring of viscoelastic properties during the production phase of composites. The viscoelastic properties are studied using theoretical models, numerical simulations and experimental measurements. Calibration studies were carried out to study the influencing factors on the monitoring of ultrasonic properties during the RTM process. The monitoring of viscoelastic parameters of epoxy resins is performed in a first time at low temperature during an isothermal polymerization and a post-curing. Then, an approach based on the transmission mode characterization was developed to study high-temperature behavior. Based on analytical approaches, the electroacoustic response was simulated by Debye series method (DSM). The use of phased array transducers was investigated for the location and sizing of defects during the movement of the carbon fiber in a liquid resin between the molds.
40

Etude mathématiques et simulations numériques de modèles de gaines bi-cinétiques / Mathematical study and numerical simulations of bi-kinetic sheath models

Badsi, Mehdi 10 October 2016 (has links)
Les résultats présentés dans cette thèse portent sur la construction et la simulation numérique de modèles théoriques de plasmas en présence d'une paroi absorbante. Ces modèles se basent sur des systèmes de Vlasov-Poisson ou Vlasov-Ampère à deux espèces en présence de conditions limites. Les solutions stationnaires recherchées vérifient l'équilibre des flux de charges dans la direction perpendiculaire à la paroi. Cette propriété s'appelle l'ambipolarité. A travers l'étude d'une équation de Poisson non linéaire, on montre le caractère bien posé d'un système de Vlasov-Poisson stationnaire 1d-1v pour lequel on détermine des distributions de particules entrantes et un potential au mur qui induisent l'ambipolarité et une densité de charge positive. On donne également une estimation de la taille de la couche limite au mur. Ces résultats sont illustrés numériquement. On prouve ensuite la stabilité linéaire des solutions stationnaires électroniques pour un modèle de Vlasov-Ampère instationnaire. Enfin, on étudie un modèle de Vlasov-Poisson stationnaire 1d-3v en présence d'un champ magnétique constant et parallèle à la paroi. On détermine les distributions de particules entrantes et un potentiel au mur qui induisent l'ambipolarité. On étudie une équation de Poisson non linéaire associée au modèle à l'aide d'une fonctionnelle non linéaire d'énergie qui admet des minimiseurs. On établit des bornes de paramètres à l'intérieur desquelles notre modèle s'applique et on propose une interprétation des résultats. / This thesis focuses on the construction and the numerical simulation theoretical models of plasmas in interaction with an absorbing wall. These models are based on two species Vlasov-Poisson or Vlasov-Ampère systems in the presence of boundary conditions. The expected stationary solutions must verify the balance of the flux of charges in the orthogonal direction to the wall. This feature is called the ambipolarity.Through the study of a non linear Poisson equation, we prove the well-posedness of 1d-1v stationary Vlasov-Poisson system, for which we determine incoming particles distributions and a wall potential that induces the ambipolarity as well as a non negative charge density hold. We also give a quantitative estimates of the thickness of the boundary layer that develops at the wall. These results are illustrated numerically. We prove the linear stability of the electronic stationary solution for a non-stationary Vlasov-Ampère system. Finally, we study a 1d-3v stationary Vlasov-Poisson system in the presence of a constant and parallel to the wall magnetic field . We determine incoming particles distributions and a wall potential so that the ambipolarity holds. We study a non linear Poisson equation through a non linear functional energy that admits minimizers. We established some bounds on the numerical parameters inside which, our model is relevant and we propose an interpretation of the results.

Page generated in 0.0335 seconds