Spelling suggestions: "subject:"Dental implants."" "subject:"Dental iomplants.""
391 |
The tensile bond strength of odontosil silicone to a heat polymerizing acrylic resin by four primers /Pengmanivong, Douangsavanh, Widchaya Kanchanavasita, January 2008 (has links) (PDF)
Thesis (M.Sc. (Maxillofacial Prosthetics))--Mahidol University, 2008. / LICL has E-Thesis 0043 ; please contact computer services. LIRV has E-Thesis 0043 ; please contact circulation services.
|
392 |
Effects of an air-powder abrasive system on smooth titanium surface a pilot study : a theses submitted in partial fulfillment ... prosthodontics ... /Han, Jung-Suk. January 1989 (has links)
Thesis (M.S.)--University of Michigan, 1989.
|
393 |
Microhardness, strains and microdamage in bone surrounding endosseous implants subjected to bending fatigue loadsHuja, Sarandeep Singh, January 1999 (has links)
Thesis (Ph. D.)--Indiana University School of Dentistry, 1999. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
394 |
Histological, radiographic, and clinical evaluation of blade implants with post-cuffing materials using monkey mandibles thesis submitted in partial fulfillment ... denture prosthodontics ... /Hubinger, Carl D. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
|
395 |
Mechanisms regulating osteoblast response to surface microtopography and vitamin DBell, Bryan Frederick. January 2009 (has links)
Thesis (Ph.D)--Materials Science and Engineering, Georgia Institute of Technology, 2010. / Committee Chair: Barbara Boyan; Committee Member: Andres Garcia; Committee Member: Anthony Norman; Committee Member: Nael McCarty; Committee Member: Zvi Schwartz. Part of the SMARTech Electronic Thesis and Dissertation Collection.
|
396 |
Microhardness, strains and microdamage in bone surrounding endosseous implants subjected to bending fatigue loadsHuja, Sarandeep Singh, January 1999 (has links)
Thesis (Ph. D.)--Indiana University School of Dentistry, 1999. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
397 |
Micro-computed tomographic analysis of bone healing subsequent to graft placementChopra, Preeti M. January 2006 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2006. / Title from first page of PDF file (viewed Oct. 30, 2007). Page 55 blank. Includes bibliographical references (p. 52-54).
|
398 |
Efeito da altura da união implante/componente protético sobre os tecidos periimplantares : estudo clínico e radiográfico em cães /Paula, Wagner Nunes de. January 2008 (has links)
Resumo: O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / Abstract: The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Walter Martins Junior / Banca: Luis Antonio Borelli Barros / Mestre
|
399 |
Avaliação de uma máquina de testes de flexão rotacional e seus efeitos em dois sistemas de implante de hexágono externo / Evaluation of a rotating bending machine and its effects on two external hex implant systemLuiz Alves de Oliveira Neto 30 May 2011 (has links)
O sucesso do tratamento com implantes depende do conhecimento teórico-prático do profissional, das condições biológicas do paciente, e também das propriedades mecânicas dos componentes protéticos e cirúrgicos. A complicação mecânica mais comum é a mobilidade da prótese relacionada ao afrouxamento ou fratura dos parafusos protéticos. Dois testes de fadiga podem avaliar as propriedades mecânicas destes materiais: ensaios monotônicos unidirecionais e testes de flexão rotacional. As vantagens dos dispositivos de flexão rotacional são: baixo custo, ensaios mais rápidos, permite gerar dados relevantes e fornece uma previsão mais realista da longevidade clínica. Desta forma, o objetivo deste trabalho foi avaliar o funcionamento do dispositivo de flexão rotacional desenvolvido por Ferreira (2010) e os seus efeitos em dois sistemas de implante de hexágono externo (Munhão Personalizável-Neodent e Pilar Cônico-Neodent). A amostra foi composta por 2 grupos: A- 5 implantes com munhão; B- 5 implantes com Pilar Cônico. Os pilares protéticos foram adaptados para o dispositivo e instalados com torque recomendado pelo fabricante. A carga cíclica de 29,4 N foi aplicada em ângulo de 45 º sobre o eixo longitudinal dos espécimes a uma frequência de 18Hz. O número de ciclos para falhar foi registrado e estabelecido um limite máximo de 5x106. Após a ciclagem, o torque de remoção foi mensurado eletronicamente e os componentes da interface implante-intermediário foram analisados através de um microscópio eletrônico de varredura (MEV). Na configuração escolhida para os testes, nenhuma das amostras sofreu falhas críticas (fratura ou soltura) durante 5x106 ciclos. Os grupos apresentaram redução no torque de pelo menos 10 NCm nos parafusos de fixação. As imagens do MEV demonstraram nível reduzido de deformação e desgastes das amostras. Componentes do dispositivo precisam ser revistos para assegurar melhor fixação do implante, controle adequado de temperatura, estabelecimento da frequência e carga ideais, visando também possibilitar aumento do momento de força aplicado aos espécimes. O dispositivo de Ferreira (2010) demonstrou ser um aparelho portátil, resistente e versátil, mas necessita de adaptações para se tornar apto a realizar quaisquer ensaios de flexão rotativa. / Implant treatment success depends on theoretical and practical knowledge, biological conditions of the patient, and also mechanical properties of surgical and prosthetic components. The most common mechanical complications are prosthesis mobility related to abutment and/or prosthetic screw fracture or loosening. Two fatigue tests can study mechanical properties of these materials: Unidirectional bend-release fatigue testing and rotational fatigue testing. The advantages of rotational bending devices include lower cost, faster tests, can generate relevant data and provide more realistic prediction of clinical performance. Thus, the aim of this study was evaluate the performance of a rotating bending device developed by Ferreira (2010) and its effects on two external hex implant systems (conical abutment-Neodent and personalized abutment-Neodent). The sample comprised two groups: A-5 with Munhão system B-5 with Conical abutment. The abutments were adapted to the device and installed with recommended torque by manufacturer. A cyclic load of 29,4 N was applied 45º angled on the long axis of the specimens at a rate of 18 Hz. The number of cycles to failure was recorded. A cutoff of 5x106 cycles was applied as an upper limit. After cycling, torque force was electronically measured and components of implant-abutment interface were analyzed using a scanning electron microscope (SEM). In chosen test configurations, none of specimens suffered critical failures (fracture/loosening) for 5x106 cycles. Both groups had torque reduction at least 10 Ncm in abutment screws. SEM images showed a low level deformation and wear of samples. Testing machine components must be reviewed to ensure better implant fixation, adequate temperature control, establish ideal frequency and load, also aiming to increase bending force moment applied to specimens. Ferreira (2010) devices proved to be a portable, rugged and versatile, but require adaptations to become able to perform any rotational bending tests.
|
400 |
Efeitos da radioterapia na obtenção da osseointegração em ratos / Effects of radiotherapy in obtaining osseointegration in ratsKamezawa, Leonardo Silva Gomes 11 December 2017 (has links)
Submitted by Leonardo Silva Gomes null (drleonardosgomes@gmail.com) on 2018-01-22T00:28:55Z
No. of bitstreams: 1
Dissertação corrigida.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-23T19:48:52Z (GMT) No. of bitstreams: 1
kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Made available in DSpace on 2018-01-23T19:48:52Z (GMT). No. of bitstreams: 1
kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5)
Previous issue date: 2017-12-11 / A radioterapia é o uso da aplicação de radiação ionizante em áreas específicas, visando tratamento de tumores. Porém, a área irradiada e os tecidos normais circundantes estão sujeitos a danos agudos e crônicos. As injúrias no tecido ósseo variam desde osteopenia até osteorradionecrose e, devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo deste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea e na osseointegração de implantes em fêmures de ratos. Foram utilizados neste estudo 66 ratos que receberam implantes cilíndricos de titânio comercialmente puro (TiCp) nos fêmures direito e esquerdo. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação precoce (Ip): cirurgia de colocação dos implantes seguido de irradiação após 24h; c) Grupo irradiado (I): irradiação e após 4 semanas, cirurgia de colocação dos implantes. Os animais dos grupos Ip e I foram submetidos a irradiação em 02 sessões de 15 Gy, totalizando a dose de 30 Gy. Os animais foram eutanasiados nos períodos de 2 e 7 semanas após o tratamento. Durante o experimento, os animais foram cuidadosamente monitorados quanto as alterações clínicas. Em cada período, 06 animais foram submetidos à análise histomorfométrica, visando avaliar a neoformação óssea e a interface osso-implante. Os outros 05 animais, dos períodos de 2 e 7 semanas após o tratamento, foram submetidos ao teste de torque reverso para avaliar a força de fixação osso-implante, obtida na osseointegração. Todos os dados foram estatisticamente analisados por meio da análise de variância de 2 fatores para torque reverso, porcentagem de área de formação óssea (BAFO) e porcentagem de superfície de contato osso implante (BIC) com nível de significância a 5%. O teste de Tukey foi realizado para determinação dos grupos homogêneos. A irradiação ionizante influenciou negativamente de maneira estatisticamente significante, retardando o processo de osseointegração, porém, não sendo capaz de inibí-lo. / The radiotherapy is ionizing radiation proceeding in specific areas, aiming at the treatment of tumors. However, the irradiated area and the surrounding normal tissue can develop acute and chronic damage. In bone tissue, injuries ranging from osteopenia to osteroadionecrosis and due to these changes patients irradiated with implants have shown higher failure rate. The objective of this study was to evaluate the effects of radiation, simulating a total dose of a conventional radiotherapy treatment for cancer, bone regeneration and osseointegration of implants in femurs of rats. It was used in this study 66 mice that receive cylindrical implants of commercially pure titanium (cpTi) on the right and left femurs. The animals were divided into 3 groups: a) control group (C): implant placement surgery (control group - healthy tissue without irradiation); b) Group early irradiation (Ip): placement of implants surgery followed by radiation after 24h; c) Group irradiated (I): irradiation and after 4 weeks of surgery implant placement. The animals of the Ip and I groups were subjected to irradiation in a double step at a dose of 15 Gy each, totalizing dose of 30 Gy. The animals were euthanized at periods of 2 and 7 weeks after treatment. During the experiment, the animals were carefully monitored for clinical changes. In each period 06 animals were submitted to histomorphometric analysis, to evaluate the bone formation and boneimplant interface. The other 05 animals, in periods of 2 and 7 weeks after treatment, were submitted to the reverse switch test to evaluate the strength of bone-implant fixation, obtained in osseointegration. All data were statistically analyzed by means of the 2-factor variance analysis for reverse torque, percentage of bone area fraction occupancy (BAFO) and percentage of bone implant contact (BIC) with significance level at 5%. The Tukey test was performed to determine the homogeneous groups. The ionizing radiation influenced negatively in a statistically significant way, delaying the process of osseointegration, but not being able to inhibit it.
|
Page generated in 0.0536 seconds