• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 30
  • 8
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 138
  • 138
  • 82
  • 33
  • 27
  • 26
  • 26
  • 25
  • 20
  • 19
  • 12
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado /

Firoozmand, Leily Macedo. January 2005 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Amélia Máximo de Araújo / Banca: Maria Antonia Pereira / Banca: João Carlos da Rocha / Resumo: O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / Abstract: The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness. / Mestre
132

Análise cinético-funcional comparativa no procedimento de exodontia via fórceps convencional (utilizando empunhadura reversa) e ergofórceps

Garcia, Luciane Tomasi Dalmolin 26 September 2013 (has links)
A ergonomia aplicada à atividade odontológica visa racionalizar os procedimentos, evitando fadigas e desgastes desnecessários aos profissionais, ao mesmo tempo em que oferece segurança e conforto ao paciente. A exodontia, dentre os diversos procedimentos cirúrgicos, é considerada aquele que ocasiona maior desgaste e fadiga ao cirurgião-dentista. Visando minimizar essas dificuldades, Pece e Naressi (1995) desenvolveram uma sistemática exodôntica diferenciada/ergonômica e respectivo instrumento, um fórceps (Ergofórceps). Este trabalho tem por objetivo comparar cinético-funcionalmente a atividade de exodontia quando realizada com fórceps convencional e com fórceps ergonômico. Para esta pesquisa, vinte voluntários do curso de odontologia da Universidade Federal do Paraná foram analisados durante a realização da atividade de exodontia via alveolar. Imagens fotográficas e filmagens serviram de base na aplicação das ferramentas ergonômicas RULA e Moore Garg (Strain Índex), além da aplicação de um questionário aos participantes. Estas ferramentas foram selecionadas por terem sido consideradas as mais adequadas para avaliar, de forma específica, os esforços realizados nos membros superiores. A empunhadura utilizada com o fórceps convencional foi a reversa, que apresenta vantagens biomecânicas sobre a tradicional. Os resultados obtidos com o método RULA com os voluntários que utilizaram o fórceps foram: 70% escore 5 (risco moderado) e 30% escore 6 (risco moderado). Já os voluntários que utilizaram o Ergofórceps foram: 70% escore 4 (baixo risco) e 30% escore 3 (baixo risco). Com o método Moore Garg as pontuações para os voluntários que utilizaram o fórceps foram: 30% escore foi 3 (duvidoso) e 70% escore 4,5 (duvidoso). Já os voluntários que utilizaram o Ergofórceps as pontuações foram: 90% o escore foi 1 (baixo risco) e em 10% foi 2 (baixo risco). Os resultados sugerem que o risco do desenvolvimento de lesões ocupacionais em dentistas é menor quando o profissional utiliza o Ergofórceps. / Ergonomics applied to the dental activity aims to rationalize the procedures, avoiding unnecessary fatigue to the professional, while still offering safety and comfort to the patient. The extraction, among the several surgical procedures, is considered to cause increased wear and fatigue. To minimize these difficulties, Pece and Naressi (1995) developed a systematic and differentiated extraction technique and the corresponding instrument, a forceps named Ergoforceps. This study aims to compare kinetically and functionally the activity of extraction with the conventional forceps and the ergonomic forceps. For this research, twenty volunteers from the dentistry course of UFPR were analyzed during the activity of alveolar extraction. Photographic images and footage formed the basis for the application of RULA and MOORE GARG (Strain Index) tools. A questionnaire was also applied to the volunteers. These ergonomic analysis tools were selected since they were considered the most suitable to assess the effort made by the upper limbs. The grip used with the conventional forceps was the reverse, which has biomechanical advantages over the traditional. The results obtained with the RULA method for the extraction forceps were: 70% score 5 (moderate risk) and 30% score 6 (moderate risk). In contrast, when the Ergoforceps was used: 70% score 4 (low risk) and 30% score 3 (low risk). With the Moore Garg tool, the score of the volunteers when using the extraction forceps were: 30% score 3 (doubtful) and 70% score 4.5 (doubtful). In contrast, when the Ergofórceps was used the score was: 90% score 1 (low risk) and 10% score 2 (low risk). The results suggest that systematic extraction undergone with the Ergoforceps has ergonomic advantages and reduces the risk of developing occupational injuries among dentists.
133

Análise cinético-funcional comparativa no procedimento de exodontia via fórceps convencional (utilizando empunhadura reversa) e ergofórceps

Garcia, Luciane Tomasi Dalmolin 26 September 2013 (has links)
A ergonomia aplicada à atividade odontológica visa racionalizar os procedimentos, evitando fadigas e desgastes desnecessários aos profissionais, ao mesmo tempo em que oferece segurança e conforto ao paciente. A exodontia, dentre os diversos procedimentos cirúrgicos, é considerada aquele que ocasiona maior desgaste e fadiga ao cirurgião-dentista. Visando minimizar essas dificuldades, Pece e Naressi (1995) desenvolveram uma sistemática exodôntica diferenciada/ergonômica e respectivo instrumento, um fórceps (Ergofórceps). Este trabalho tem por objetivo comparar cinético-funcionalmente a atividade de exodontia quando realizada com fórceps convencional e com fórceps ergonômico. Para esta pesquisa, vinte voluntários do curso de odontologia da Universidade Federal do Paraná foram analisados durante a realização da atividade de exodontia via alveolar. Imagens fotográficas e filmagens serviram de base na aplicação das ferramentas ergonômicas RULA e Moore Garg (Strain Índex), além da aplicação de um questionário aos participantes. Estas ferramentas foram selecionadas por terem sido consideradas as mais adequadas para avaliar, de forma específica, os esforços realizados nos membros superiores. A empunhadura utilizada com o fórceps convencional foi a reversa, que apresenta vantagens biomecânicas sobre a tradicional. Os resultados obtidos com o método RULA com os voluntários que utilizaram o fórceps foram: 70% escore 5 (risco moderado) e 30% escore 6 (risco moderado). Já os voluntários que utilizaram o Ergofórceps foram: 70% escore 4 (baixo risco) e 30% escore 3 (baixo risco). Com o método Moore Garg as pontuações para os voluntários que utilizaram o fórceps foram: 30% escore foi 3 (duvidoso) e 70% escore 4,5 (duvidoso). Já os voluntários que utilizaram o Ergofórceps as pontuações foram: 90% o escore foi 1 (baixo risco) e em 10% foi 2 (baixo risco). Os resultados sugerem que o risco do desenvolvimento de lesões ocupacionais em dentistas é menor quando o profissional utiliza o Ergofórceps. / Ergonomics applied to the dental activity aims to rationalize the procedures, avoiding unnecessary fatigue to the professional, while still offering safety and comfort to the patient. The extraction, among the several surgical procedures, is considered to cause increased wear and fatigue. To minimize these difficulties, Pece and Naressi (1995) developed a systematic and differentiated extraction technique and the corresponding instrument, a forceps named Ergoforceps. This study aims to compare kinetically and functionally the activity of extraction with the conventional forceps and the ergonomic forceps. For this research, twenty volunteers from the dentistry course of UFPR were analyzed during the activity of alveolar extraction. Photographic images and footage formed the basis for the application of RULA and MOORE GARG (Strain Index) tools. A questionnaire was also applied to the volunteers. These ergonomic analysis tools were selected since they were considered the most suitable to assess the effort made by the upper limbs. The grip used with the conventional forceps was the reverse, which has biomechanical advantages over the traditional. The results obtained with the RULA method for the extraction forceps were: 70% score 5 (moderate risk) and 30% score 6 (moderate risk). In contrast, when the Ergoforceps was used: 70% score 4 (low risk) and 30% score 3 (low risk). With the Moore Garg tool, the score of the volunteers when using the extraction forceps were: 30% score 3 (doubtful) and 70% score 4.5 (doubtful). In contrast, when the Ergofórceps was used the score was: 90% score 1 (low risk) and 10% score 2 (low risk). The results suggest that systematic extraction undergone with the Ergoforceps has ergonomic advantages and reduces the risk of developing occupational injuries among dentists.
134

Endodontski retretman-analiza skening elektronskom mikroskopijom / Endodontic retreatment –scanning electron microscopy analysis

Vukoje Karolina 09 December 2015 (has links)
<p>U slučajevima neuspe&scaron;ne endodontske terapije, neophodno je ponovno lečenje kanala korena. Ortogradni endodontski retretman podrazumeva uklanjanje postojećeg materijala za punjenje iz kanala uz dodatno či&scaron;ćenje, dezinfekciju i ponovnu finalnu opturaciju kanala. Važan korak u toku retretmana je &scaron;to potpunije uklanjanje postojećeg kanalnog punjenja kako bi se pristupilo svim delovima kanalnog sistema. Cilj doktorske teze bio je da se ispita kvalitet čis&scaron;ćenja zidova kanala korena nakon endodontskog retretmana pomoću skening elektronske mikroskopije (SEM). Posmatran je uticaj vrste materijala za opturaciju, uticaj upotrebe rastvarača i uticaj ručnih i ma&scaron;inskih instrumenata na količinu zaostalog materijala na zidovima kanala. Takođe, ispitan je uticaj ovih faktora na apikalnu transportaciju materijala i na vreme potrebno za retretman, a utvrđena je i učestalost o&scaron;tećenja kori&scaron;ćenih instrumenata. Materijal i metode: Ukupan uzorak činilo je 125 ekstrahovanih, humanih jednokorenih zuba. Nakon preparacije kanala korena, 120 zuba je podeljeno u dve grupe i napunjeno pomoću dva različita materijala za opturaciju (gutaperkom i resilonom). U zavisnosti od tehnike uklanjanja ovih materijala, grupe su dalje podeljene u odnosu na kori&scaron;ćene instrumente (Hedstrom, ProTaper i Twisted File) i u odnosu na upotrebu rastvarača (sa i bez hloroforma). Preostalih 5 zuba, bez kanalnog punjenja, kori&scaron;ćeni su kao kontrolna grupa. Nakon zavr&scaron;enog retretmana, korenovi su uzdužnim cepanjem razdvojeni, a odabrane polovine posmatrane na SEM-u. Mikrofotografije svake trećine kanala načinjene su pri uveličanju od 500x. Količina preostalog materijala za punjenje ocenjivana je pomoću skale. Otvoreni dentinski kanalići prebrojavani su na mikrofotografijama načinjenim pri uveličanju od 1000x, u odnosu na uvek konstantnu povr&scaron;inu. Rezultati: Analiza rezultata ukazala je na postojanje statistički značajne razlike u kvalitetu či&scaron;ćenja zidova kanala u zavisnosti od uklanjanog materijala za opturaciju. Kvalitet či&scaron;ćenja zidova kanala bio je veći nakon uklanjanja gutaperke nego nakon uklanjanja resilona. Rotirajućim, ma&scaron;inskim instrumentima je efikasnije uklanjana gutaperka, a ručnim Hedstrom turpijama je bolje uklanjan resilon. Posmatrajući ceo uzorak, ProTaper instrumenti ostavljali su velike količine materijala na zidovima kanala nakon endodontskog retretmana. Međutim, uklanjanje materijala pomoću ovih instrumenata bilo je najbrže. Primena rastvarača značajno je doprinela bržem uklanjanju materijala, dok uticaj na kvalitet či&scaron;ćenja zidova kanala nije bio značajan. Posmatrajući kanal korena po trećinama, najveća količina materijala nalazila se u apikalnoj trećini, bez obzira na vrstu uklanjanog materijala i kori&scaron;ćenih instrumenata, i bez obzira na upotrebu rastvarača tokom retretmana. Učestalost o&scaron;tećenja instrumenata bila je značajno veća prilikom upotrebe Twisted File instrumenata. Apikalna transportacija materijala je bila veća tokom uklanjanja resilon materijala i kada su kori&scaron;ćene ručne Hedstrom turpije. Zaključak: Kvalitet či&scaron;ćenja zidova kanala nakon uklanjanja gutaperke je veći nego nakon uklanjanja resilona. Dizajn i vrsta instrumenata utiče na kvalitet či&scaron;ćenja zidova kanala korena. Upotreba rastvarača tokom retretmana ne utiče značajno na smanjenje količine materijala zaostalog na zidovima kanala. Ma&scaron;inski pokretani instrumenti i upotreba rastvarača značajno skraćuju vreme potrebno za endodontski retretman.</p> / <p>In cases when endodontic treatment fails, it is necessary to retreat the root canal. Orthograde endodontic retreatment requires the removal of the existing root filling material with additional cleaning, disinfection and refilling of the canal. An important step during retreatment is complete removal of existing filling materials, to regain access to all parts of the canal system. The aim of the doctoral thesis was to investigate the cleanliness of root canal walls after removal of two different obturation material. The retreatment efficacy was observed depending on the usage of solvent and different hand or rotary instruments. The amount of residual material on the canal walls was assessed using scanning electron microscopy (SEM). Also, apical transportation of the obturation material, working time and frequency of instrument damage during retreatment was recorded. Materials and Methods: The total sample consisted of 125 extracted, single-rooted human teeth. After root canal preparation, 120 teeth were divided in two groups and filled using two different obturation materials (gutta-percha and resilon). Depending on the technique of removing these materials, the groups were further divided, in relation to the used instruments (Hedstrom, ProTaper and Twisted File), as well as in relation to the use of solvent (with or without chloroform). The remaining 5 tooth without canal filling were used as a control group. After root canal desopturation, the longitudinaly splitted root halves were observed on SEM. Microphotography of each third were made at magnification of 500x. The amount of remaining filling material was evaluated by using a scale. Open dentinal tubules were counted on microphotographies made at a magnificiation of 1000x, on a surface that was always constant. Results: Analysis of the results indicated a significant difference in the cleanliness of the canal walls depending on the used obturation material. Cleanliness of the canal walls was higher after gutta-percha removal than after the removal of resilon.&nbsp; Rotary instruments were more effective in removing gutta-percha and Hedstrom hand files better removed resilon. ProTaper instruments left more residual material on canal walls, however endodontic retreatment with these instruments was the fastest. The application of solvent significantly contributed to faster material removal, while the impact on the increase of canal cleanliness was not significant. The largest amount of material remained in the apical third, regardless of the type of material removed and instruments used, and also regardless whether solvent was used for retreatment. The frequency of instrument deformation and fracture was significantly higher when Twisted File instruments were used. Apical transportation of material had a significantly higher occurrence during resilon removal and when manual Hedstrom files were used. Conclusion: Cleanliness of the canal walls was higher after the removal of gutta-percha than after the removal of resilon. The use of solvent is not significant on the increase of canal wall cleanliness, but significantly shortens the time needed for retreatment. There is a difference in the cleanliness of root canal walls depending on the used instruments. Engine-driven rotary instruments and the use of a solvent significantly shortens the time needed for endodontic retreatment.</p>
135

EFEITO DO DESGASTE COM INSTRUMENTOS DIAMANTADOS E DA DEGRADAÇÃO A BAIXAS TEMPERATURAS NO COMPORTAMENTO MECÂNICO DE UMA CERÂMICA Y-TZP / EFFECT OF GRINDING WITH DIAMOND INSTRUMENTS AND LOWTEMPERATURE DEGRADATION ON THE MECHANICAL BEHAVIOR OF A Y-TZP CERAMIC.

Pereira, Gabriel Kalil Rocha 05 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objectives: (1) Compare the effects of grinding on a Y-TZP ceramic executed by diamond discs and diamond burs (with similar grit sizes) in the micromorphology of surface, phase transformation (t®m), flexural strength and structural reliability (Weibull analysis), (2) evaluate the effect of LTD (low-temperature degradation) in the outcomes mentioned above. Methods: Three hundred and sixty discs (15mm x 1,2 mm) of Y-TZP were made according to ISO 6872 2008 for flexural strength determination on ceramic materials and sintered according to the manufacturer`s instructions, than they were divided into groups according to two factors in study: surface treatment - 5 levels (without treatment, extra-fine diamond bur, 600-grit diamond disc, coarse diamond bur and 120-grit diamond disc) and LTD on 2 levels (with and without). For grinding with diamond discs a polishing machine was employed, while for grinding with diamond burs a device was employed to assure the perpendicularity between diamond tip and abrading surface, that way the abrasion movements and the applied pressure were standardized. The LTD was induced in an autoclave at 134ºC under 2 bar for 20 hours. Results: Our findings support that LTD although promoted increase in mphase content and micromorphological alterations did not promoted decrease in zirconia s mechanical properties, grinding at a first moment did not affected too, but when ground Y-TZP was submitted to the LTD effects, the defects introduced by grinding could be detrimental to the material`s resistance. From a methodological point of view, diamond discs should not be employed to simulate clinical abrasion performed with diamond burs on Y-TZP ceramics. Conclusion: Thus grinding of zirconia should be avoided and when it was really necessary tools with low grit sizes should be employed. / Objetivos: (1) Comparar os efeitos do desgaste da cerâmica Y-TZP gerados por lixas e pontas diamantadas (com granulações semelhantes) na micromorfologia da superfície, na transformação de fase (t®m), na resistência à flexão biaxial e confiabilidade estrutural (análise de Weibull), (2) Avaliar o efeito da LTD nos desfechos citados acima. Métodos: Trezentos e sessenta discos (15 mm x 1,2 mm) de Y-TZP foram confeccionados segundo as instruções da ISO 6872 2008 para ensaios de flexão em material cerâmico e sinterizados de acordo com as recomendações do fabricante, posteriormente foram divididos em grupos, de acordo com dois fatores em estudo: tratamento de superfície da cerâmica - 5 níveis (sem tratamento, disco de granulação 120, ponta diamantada de granulação super grossa, disco de granulação 600, ponta diamantada extra fina) e LTD - 2 níveis (sem e com). Para abrasão com lixas de diferentes granulações foi utilizada uma politriz, enquanto que para a abrasão com as pontas diamantadas foi utilizado um dispositivo que garantiu a perpendicularidade da ponta diamantada à superfície da amostra, padronizando os movimentos de abrasão e a pressão aplicada. A LTD foi realizada em autoclave sob 134° C à 2 bar por 20 horas. Resultados: Nossos achados suportam que a LTD embora promovesse aumento de fase monoclínica e alterações micromorfológicas não causou perda de propriedades mecânicas da zircônia, o desgaste em primeiro momento também não promoveu, mas quando esta superfície foi submetida aos efeitos da LTD, os defeitos introduzidos pelo desgaste podem ser prejudiciais a resistência do material. Sob um ponto de vista metodológico o uso de discos diamantados não deve ser empregado para simular o desgaste executado clinicamente com pontas diamantadas. Conclusão: Dessa forma o desgaste da superfície da zircônia deve ser evitado e quando necessário deve ser realizado com instrumentos de menor granulação.
136

Máquinas lavadoras ultrassônicas de instrumentos odontológicos, médicos e cirúrgicos: avaliação do desempenho do processo de limpeza

Albrecht, Lucimara 28 February 2013 (has links)
A limpeza de instrumentos odontológicos, médicos e cirúrgicos (IOMC) em máquina lavadora ultrassônica (MLUS) utiliza energia mecânica (vibrações sonoras - cavitação), química (soluções detergentes) e térmica (temperatura) associadas ao tempo de exposição. A eficácia deste processo é certificada por meio de testes de controle recomendados por normas internacionais. Neste estudo buscou-se avaliar o desempenho da MLUS quanto aos parâmetros mínimos aceitáveis nas condições práticas de uso através de testes descritos em normas e discutir os fatores de interferência durante o processo que podem comprometer a eficiência da limpeza dos IOMC. Uma pesquisa inicial analisou as condições operacionais da MLUS por meio de questionário auto-aplicado nos estabelecimentos assistenciais à saúde (EAS) de Curitiba mostrando amplo uso da MLUS, com procedimentos técnicos de preparo do processo de limpeza, relação de tempo/temperatura e perfil dos ciclos com a carga de acordo com recomendações da literatura. Entretanto, não houve consenso sobre testes e normas técnicas a serem aplicadas. Assim, foram realizados testes de tiras e folhas de alumínio, indicadores químicos Sono Check® e TOSI® Lum Check para instrumentais canulados baseados em normas internacionais. Os resultados mostraram que todas as folhas de alumínio testadas apresentaram padrão uniforme de perfurações (100%), indicando a eficiência da cavitação. Nas tiras de folhas de alumínio houve perfurações semelhantes na maioria delas (89%) e uma apresentou poucas alterações (11%) apontando falhas no teste e/ou no funcionamento do equipamento. Em 3 testes de indicadores químicos Sono Check® foi obtido resultado positivo (37,5%), em outros três houve demora na alteração da cor mas acabaram positivos (37,5%) e dois indicadores de 2 testes não alteraram a cor (25%). Os resultados positivos (75%) comprovaram a eficácia da atividade ultrassônica e os negativos indicaram pontos cegos no processo de cavitação, o que pode ser atribuído a fatores interferentes na limpeza como: uso da mesma solução de limpeza em vários ciclos, tipo e disposição da carga, nível de preenchimento da solução no tanque, temperatura e divergência das ondas ultrassônicas entre instrumentais e paredes do equipamento. Os resultados dos testes TOSI® Lum Check foram negativos pois apresentaram resíduos de fibrina na superfície das placas de aço que pode estar relacionado a um reduzido tempo de exposição, temperatura não adequada, qualidade da água, diluição incorreta da solução de limpeza, teste mal posicionado, sobrecarga e/ou carga incorreta de IOMC e ineficiência da solução limpante. Concluiu-se que os testes de controle comprovam a eficácia da atividade ultrassônica na limpeza e detectam falhas no desempenho da MLUS atribuídas a fatores interferentes citados e para tanto é recomendado a elaboração de uma norma técnica no Brasil com a implementação da monitoração da atividade ultrassônica para a garantia da qualidade do processo de limpeza ultrassônica. / The cleaning of dental, medical and surgical instruments (DMSI) with ultrasonic cleaning equipment (UCE) makes use of mechanical (sound vibrations – cavitation), chemical (detergent solutions) and thermal (temperature) energies associated with exposure time. To check the performance of the cleaning process it is necessary the use of tests recommended by international standards. In this study we have evaluated the performance of UCE concerning its minimal acceptable parameters by means of tests described on standards as well as discussing the interfering factors which could compromise the cleaning process of DMSI. Initially, a survey analyzed the operating conditions of UEC through a questionnaire answered by professionals of several health care establishments (HCE) of Curitiba city. The results showed wide use of UCE in the investigated HCE, technical procedures for preparation of the cleaning process, time/temperature relationship and load cycle profiles according to literature recommendations. However there was no agreement on the type test selection or adoption of technical standards. Considering those results, practical tests were carried out for aluminium foils and strips, Sono Check® chemical indicators and TOSI® Lum Check for cannulated instruments, based on international standards. Aluminium foils (100%) and strips (89%) have showed uniformity in the produced holes, indicating efficiency of the cavitation. Some strips presented few modifications (11%), indicating failures in the test and/or functioning of the equipment. Chemical indicators Sono Check®| presented positive results (75%) proving the effectiveness of ultrasonic activity, however some (25%) presented negative results indicating blind spots due to difficulties in the cavitation process, which can be attributed to interfering factors such as: use the same cleaning solution in several cycles, type and disposition of the load, level of the solution in the tank, temperature and divergence of ultrasonic waves between instrument and walls of the equipment. TOSI® Lum Check for cannulated instruments showed negative results which can be attributed to reduced exposure time, not adequate temperature, water quality, incorrect dilution of the cleaning solution, test bad positioned, overload and/or incorrect load of the instruments, and inefficiency of the cleaning solution. It was concluded that the control tests can prove the effectiveness of the ultrasound in the cleaning activity and detect performance failures for UCE assigned to the cited interfering factors. Therefore, it is recommended the development of a technical standard in Brazil which should include types of tests, procedures and operational control of the cycle parameters in order to ensure the quality control of the ultrasonic cleaning process.
137

Máquinas lavadoras ultrassônicas de instrumentos odontológicos, médicos e cirúrgicos: avaliação do desempenho do processo de limpeza

Albrecht, Lucimara 28 February 2013 (has links)
A limpeza de instrumentos odontológicos, médicos e cirúrgicos (IOMC) em máquina lavadora ultrassônica (MLUS) utiliza energia mecânica (vibrações sonoras - cavitação), química (soluções detergentes) e térmica (temperatura) associadas ao tempo de exposição. A eficácia deste processo é certificada por meio de testes de controle recomendados por normas internacionais. Neste estudo buscou-se avaliar o desempenho da MLUS quanto aos parâmetros mínimos aceitáveis nas condições práticas de uso através de testes descritos em normas e discutir os fatores de interferência durante o processo que podem comprometer a eficiência da limpeza dos IOMC. Uma pesquisa inicial analisou as condições operacionais da MLUS por meio de questionário auto-aplicado nos estabelecimentos assistenciais à saúde (EAS) de Curitiba mostrando amplo uso da MLUS, com procedimentos técnicos de preparo do processo de limpeza, relação de tempo/temperatura e perfil dos ciclos com a carga de acordo com recomendações da literatura. Entretanto, não houve consenso sobre testes e normas técnicas a serem aplicadas. Assim, foram realizados testes de tiras e folhas de alumínio, indicadores químicos Sono Check® e TOSI® Lum Check para instrumentais canulados baseados em normas internacionais. Os resultados mostraram que todas as folhas de alumínio testadas apresentaram padrão uniforme de perfurações (100%), indicando a eficiência da cavitação. Nas tiras de folhas de alumínio houve perfurações semelhantes na maioria delas (89%) e uma apresentou poucas alterações (11%) apontando falhas no teste e/ou no funcionamento do equipamento. Em 3 testes de indicadores químicos Sono Check® foi obtido resultado positivo (37,5%), em outros três houve demora na alteração da cor mas acabaram positivos (37,5%) e dois indicadores de 2 testes não alteraram a cor (25%). Os resultados positivos (75%) comprovaram a eficácia da atividade ultrassônica e os negativos indicaram pontos cegos no processo de cavitação, o que pode ser atribuído a fatores interferentes na limpeza como: uso da mesma solução de limpeza em vários ciclos, tipo e disposição da carga, nível de preenchimento da solução no tanque, temperatura e divergência das ondas ultrassônicas entre instrumentais e paredes do equipamento. Os resultados dos testes TOSI® Lum Check foram negativos pois apresentaram resíduos de fibrina na superfície das placas de aço que pode estar relacionado a um reduzido tempo de exposição, temperatura não adequada, qualidade da água, diluição incorreta da solução de limpeza, teste mal posicionado, sobrecarga e/ou carga incorreta de IOMC e ineficiência da solução limpante. Concluiu-se que os testes de controle comprovam a eficácia da atividade ultrassônica na limpeza e detectam falhas no desempenho da MLUS atribuídas a fatores interferentes citados e para tanto é recomendado a elaboração de uma norma técnica no Brasil com a implementação da monitoração da atividade ultrassônica para a garantia da qualidade do processo de limpeza ultrassônica. / The cleaning of dental, medical and surgical instruments (DMSI) with ultrasonic cleaning equipment (UCE) makes use of mechanical (sound vibrations – cavitation), chemical (detergent solutions) and thermal (temperature) energies associated with exposure time. To check the performance of the cleaning process it is necessary the use of tests recommended by international standards. In this study we have evaluated the performance of UCE concerning its minimal acceptable parameters by means of tests described on standards as well as discussing the interfering factors which could compromise the cleaning process of DMSI. Initially, a survey analyzed the operating conditions of UEC through a questionnaire answered by professionals of several health care establishments (HCE) of Curitiba city. The results showed wide use of UCE in the investigated HCE, technical procedures for preparation of the cleaning process, time/temperature relationship and load cycle profiles according to literature recommendations. However there was no agreement on the type test selection or adoption of technical standards. Considering those results, practical tests were carried out for aluminium foils and strips, Sono Check® chemical indicators and TOSI® Lum Check for cannulated instruments, based on international standards. Aluminium foils (100%) and strips (89%) have showed uniformity in the produced holes, indicating efficiency of the cavitation. Some strips presented few modifications (11%), indicating failures in the test and/or functioning of the equipment. Chemical indicators Sono Check®| presented positive results (75%) proving the effectiveness of ultrasonic activity, however some (25%) presented negative results indicating blind spots due to difficulties in the cavitation process, which can be attributed to interfering factors such as: use the same cleaning solution in several cycles, type and disposition of the load, level of the solution in the tank, temperature and divergence of ultrasonic waves between instrument and walls of the equipment. TOSI® Lum Check for cannulated instruments showed negative results which can be attributed to reduced exposure time, not adequate temperature, water quality, incorrect dilution of the cleaning solution, test bad positioned, overload and/or incorrect load of the instruments, and inefficiency of the cleaning solution. It was concluded that the control tests can prove the effectiveness of the ultrasound in the cleaning activity and detect performance failures for UCE assigned to the cited interfering factors. Therefore, it is recommended the development of a technical standard in Brazil which should include types of tests, procedures and operational control of the cycle parameters in order to ensure the quality control of the ultrasonic cleaning process.
138

An in-vitro SEM study comparing the debridement efficacy of the EndoVac® system versus the Canal CleanMax® following hand-rotary istrumentation

Ricketts, Benjamin P. (Benjamin Paul), 1980- January 2010 (has links)
Indiana University School of Dentistry located on the campus of Indiana University-Purdue University Indianapolis (IUPUI) / This in-vitro, prospective, randomized study microscopically compared the debridement efficacy of negative pressure irrigation with the EndoVac (Discus Dental, Culver City, CA) versus the Canal CleanMax (Maximum Dental, Inc., Secaucus, NJ). Sixty extracted human canines were instrumented using a combination of hand-instrumentation with Lexicon K-type files and rotary instrumentation with ProTaper files. All canals were irrigated with 6.0-percent sodium hypochlorite and 17- percent ethylenediaminetetraacetic acid (EDTA). However, the irrigation/aspiration techniques differed among three groups of 20 randomly selected teeth. Group one (control) was irrigated with only a 12-ml Monoject syringe via 30-gauge side-vented, closed-end needle. Group two was irrigated with the EndoVac system. Group three was irrigated similar to group one, but with the adjunct of the Canal CleanMax system. All teeth were sectioned longitudinally, and the more intact sections were divided into coronal, middle, and apical thirds. Each portion of the canal was photographed with a scanning electron microscope (SEM). The photographs were scored by two independent examiners according to relative amount of debris and/or smear layer present, as well as relative number of patent dentinal tubules. These scores were statistically analyzed using a Krustal-Wallis test and Wilcoxon Rank Sum tests to determine differences between groups. The coronal aspect of root canal walls irrigated with the EndoVac system exhibited significantly less debris and/or smear layer present when compared to the coronal aspect of root canals irrigated with only a standard 12-ml Monoject syringe equipped with 30-gauge ProRinse side-vented, closed-end needle (control). There were no other significant differences in scores between any groups at any location. For all locations combined, the EndoVac system produced significantly cleaner root canal walls as compared to the control. No significant differences were seen between the Canal CleanMax and Control or Canal CleanMax and EndoVac. This study suggested negative pressure irrigation delivery with the EndoVac system during and after hand-rotary instrumentation is more effective in removal of debris and smear layer from the coronal third and combined thirds of root canal walls compared to irrigation with a standard 12-ml Monoject syringe equipped with 30-gauge ProRinse side-vented, closed-end needle.

Page generated in 0.1001 seconds