• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 20
  • 9
  • 8
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistencia a antimicrobianos de microrganismos colhidos em artigos e equipamentos odontologicos

Motta, Rogério Heládio Lopes 05 February 2002 (has links)
Orientador: Thales Rocha de Mattos Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T10:31:26Z (GMT). No. of bitstreams: 1 Motta_RogerioHeladioLopes_M.pdf: 3737116 bytes, checksum: 4b2776a6fb8058f1adbf5dcebf1c2408 (MD5) Previous issue date: 2002 / Resumo: O correto uso de materiais esterilizados e barreiras de proteção são essenciais para o tratamento odontológico seguro, tanto para o paciente como para o cirurgião-dentista, diminuindo os riscos de contaminação cruzada. o objetivo deste trabalho foi quantificar a prevalênciade bactérias no ambiente da Clínica Odontológica da Faculdade de Odontologia de Piracicaba - UNICAMP. Foram realizadas colheitas de bactérias em diferentes locaisda Clínica utilizando-se swabs esterilizados, sendo colhidas amostras dos botões das cadeiras odontológicas, canhões de raio-X, luvas de procedimentos, maçanetas da porta de entrada da clínica, alças dos refletores, seringas tríplices e teclas "enter" dos computadores. As amostras foram colocadas em Placas de Petri contendo BHI e encubadas a 37° C, por 24 horas, assim como a 37°C, com 10% CO2, por 24 horas Os períodos de colheitas foram: antes, durante e após o término dos atendimentos da clínica. Foram contadas as unidades formadoras de colônias (ufc), sendo que a identificação presuntiva foi realizada utilizando-se o método de coloração de GRAM. A identificação das espécies foi feita através de testes bioquímicos. As bactérias colhidas foram submetidas ao teste de suscetibilidade antimicrobiana em agar, utilizando-se doze discos de antibióticos: ampicilina/10µg (amp), amoxicilina/10µg (amox), azitromicina/15µg (azi), claritromicina/15µg (cla), eritromicina/15µg (eri), cefadroxil/10µg (cef), clindamicina/2µg (clin), penicilina G/10u (pen), amoxicilina/20µg + ácido clavulânico/10µg (amox+cla), cloranfenico/30µg (cio), oxacilina 1µg (oxa) e vancomicina 30µg (van) . As porcentagens de resistência aos antimicrobianostestados foram: amp (62%), amox (68%), azi (35%), clari (58%), eri (42%), cef (56%), clin (51%), pen (71%), amox+ cla (47%), cio (31%), oxa (11%) e van (0%). Os resultados mostraram que as bactérias mais prevalentes foram os Streptococcus do grupo viridans, seguidas por Staphy/ococcus epidermidis. O botão de acionamento de cadeira foi o local com maior contaminação.O maior número de bactérias foi encontrado durante as atividades clínicas, independente da situação clínica analisada. Com os resultados do trabalho, podemos concluir que: 1) A atividade clínica aumenta a contaminação dos artigos e equipamentos odontológicos; 2) As bactérias encontradas mostraram alta porcentagem de resistência aos antibióticos testados; 3) Streptococcus do grupo viridans e Staphy/ococcus epidermidis foram os microrganismos mais encontrados / Abstract: Nowadays patients' infectious diseases mean serious risks to dentistry professionals. Thus, correct use of sterilized materiais, and self-protection equipment is essential. Bioaerosolsare an important considerationfor infection control and occupational health, since infectious agents could be transmitted via aerosols to patients or staff in the confines of the dental unit. The aim of this study was to identify microorganisms on dental equipment in the undergraduate clinic of Piracicaba Dentistry School. Also, antibiotic susceptibility tests were carried out against ali collected microorganisms. Microorganisms were collected from push buttons of dental chairs, air-water syringes, X ray device, gloves, computer keys, doorknobs, reflector handle, and lobby chairs by using sterilized swabs. They were inoculated on BHI agar, and incubated at 37°Cj24h. Ali microorganisms were collected in three different periods, before, during, and after clinical procedures. After counting, microorganisms were classified using Gram staining. Antibiotic susceptibility tests were assayed using commercial paper discs on Mueller-Hinton agar with 5% sheep-blood. Microorganisms were Gram+ cocci (67%), Gram+ bacilli(26%), Gram- cocci (5%), and others (2%). Rate of resistant strains was ampicillin/l0µg (62%), amoxicillin/l0µg (68%), azithromycin/15µg (35%), clarithromycin/15µg (58%), erythromycin/15µg (42%), cefadroxil/l0µg (56%), clindamycin/2µg (51%), penicillin/l0µ (71%), amoxicillin/20µg+clavulanic acid/10µg (47%), chloramphenicol/ 30µg (31%), oxacillin (11%)and vancomycin (0%). Push buttons of dental chairs were the most contaminated (p<0,05),and S.viridans were the most prevalent microorganisms. The highest number of microorganisms (p<0,05) was found during clinical procedures. We concluded that: increases environmental contamination;2) environmental microorganisms show high resistance rate against common antibiotics;3) S. viridans and S. epidermidis are the most common environmental microorganism / Mestrado / Farmacologia, Anestesiologia e Terapeutica / Mestre em Odontologia
2

Avaliação da padronização de agulhas anestesicas odontologicas comercializadas no Brasil

Girotto, Marcos Antonio 18 August 1998 (has links)
Orientador: Maria Cristina Volpato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T06:58:33Z (GMT). No. of bitstreams: 1 Girotto_MarcosAntonio_M.pdf: 2174892 bytes, checksum: f96234f0323f7f96124c67ae1f3d9dad (MD5) Previous issue date: 1998 / Resumo: Dada a inexistência de uma normatização para a produção de agulhas anestésicas odontológicas descartáveis no Brasil, o objetivo deste trabalho foi avaliar o grau de padronização dessas agulhas comercializadas no país no segundo semestre de 1997, a saber: longas - BD, Ibras e Nipro; Curtas ¬BD, Ibras, Injecta, Misawa, Monoject, Nipro, Terumo e Unoject. Para cada teste foram utilizadas 10 agulhas de cada marca e tamanho, escolhidas ao acaso a partir da embalagem original. Foram avaliados neste estudo as medidas das agulhas quanto ao comprimento da cânula (C1), da parte que perfura o tubete (C2) e da porção que permanece no interior do adaptador plástico (C3) e diâmetros externo (DE) e interno (DI), a resistência à corrosão da cânula e as informações da embalagem (caixa e protetor), bem como o grau de deflexão após imersão em hidrocolóide irreversível (alginato). Os resultados foram submetidos à análise e,statística, sendo aplicados os testes de Tukey-kramer-HSD ou Kruskal¬Wallis, conforme os dados. Os resultados obtidos foram comparados com as normas internacional (ISO), americana (ANSI/ADA) e francesa (NF). Para as medidas C1, C2, C3 e DI houve variação tanto para as agulhas curtas quanto para as agulhas longas, não havendo uma marca que estivesse de acordo com uma das normas para todas as medidas. O DE foi bastante uniforme, com todas as marcas em conformidade com a ANSI/ADA e NF. O coeficiente de deflexão mostrou não haver diferença estatisticamente significante entre todas as marcas, revelando ainda não haver diferenças entre os calibres 30 G e 27 G. Todas as agulhas atingiram as especificações do teste de corrosão. Algumas embalagens mostraram conteúdo de informação incompleto, com uma marca sendo vendida sem prazo de validade. Alguns protetores não permitiam identificar a violação do lacre quando isto ocorria. Conclui-se que: a) nenhuma marca estava de acordo com qualquer da normas para todas as medidas; b) o aço utilizado é compatível com o fim a que se destina; c) as informações da embalagem e o lacre protetor são insuficientes para algumas marcas; d) a deflexão não tem correlação direta com o calibre da agulha; e) há necessidade de se estabelecer normas brasileiras para regulamentar a produção e venda de agulhas odontológicas no país / Abstract: The purpose of this paper was to evaluate the standardization of sterile, single use dental injection needles marketed in Brazil in the second semester of 1997, as this country does not have an official specification for the production of this material. Ten needles of each trade mark (Iong: BD, Ibras and Nipro - short: BD, Ibras, Nipro, Injecta, Misawa, Monoject, Terumo and Unoject) were randomily selected and used for each testo It was evaluated the dimensions of effective needle length (C1), butt end length (C2), socket depth (C3), outside diameter (OD) and inside diameter (ID), the corrosion resistance of the cannula, the information printed in the delivery package and the unit delivery package, as well as the defletion of the cannula in hydrocolloid. The results were analised by Tuckey-Kramer or Kruskal-Wallis testo Data were compared to the international standard (ISO), American specification no. 54 (ANSIj ADA) and French standard (FS). There were great variation for C1, C2, C3 and ID, and no trade mark fitted in any of the standards for ali the dimensions. The outside diameter showed very little variation with ali the trade marks according to ANSIj ADA and FS. Ali the needles withstood the corrosion testo Some trade marks had incomplete information in the delivery package and one had no final safe date for use. Some of the unit delivery package, once opened, did not show clear evidence of having been opened. There were no statistically significant difference in the defletion coefficient among the trade marks and the 27 and 30 gauge needles. It was concluded that: a) no trade mark met any of the standards for ali the dimensions; b) as seen 'in the corrosion test, ali of the needles were made of stainless steel compatible with the proposed use; c) the information in the delivery package and unit delivery package are insuficient; d) there was no correlation between the outside diameter and the defletion of the cannula, and e) there is an urgent necessity of a Brazilian specification for single use dental injection needles / Mestrado / Farmacologia / Mestre em Ciências
3

Efeito de brocas para implantes sobre o tecido osseo : estudo histologico em cães

Couto Filho, Carlos Eduardo Gomes do, 1962- 23 July 2018 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T11:31:04Z (GMT). No. of bitstreams: 1 CoutoFilho_CarlosEduardoGomesdo_M.pdf: 4440845 bytes, checksum: 9f293372bb6de2d09bc9aee2f8bb3e69 (MD5) Previous issue date: 1998 / Resumo: o sucesso do tratamento, através da colocação de implantes, exige leitos receptores adequados, para que ocorra uma osseointegração ideal. O equipamento utilizado para a confecção destas cavidades deve ser o mais preciso possível, devendo promover cortes com paredes bastante regulares e sem áreas de necrose. Com o objetivo de avaliar histologicamente, o efeito das brocas para implantes sobre o tecido ósseo utilizou-se sete cães, confeccionando-se, na mandibula de cada um deles, orifícios para colocação de implantes, seguindo a seqüência de brocas sugerida pelos fabricantes dos sistemas Nobel Biocare, ImpJamed e 3i. Após a confecção das cavidades, removeu-se o fragmento ósseo, e executou-se cortes semi-seriados de 6 f.lIll, no sentido don longo eixo dos cortes, e coloração com hematoxilina e eosina. A avaliação microscópica mostrou cortes regulares com poucas áreas de necrose e esquírolas ósseas, evidenciando que a técnica utilizada foi adequada, atestando a qualidade das brocas / Abstract: The success of the treatment through the placement of osseointegrated implants will require appropriate cavities so it happen an ideal osseointegration. The equipment that was needed to make these cavities must be the most accurate promoting holes with uniform wall and without necrosls area. With intention to avaluate the histollogical effects of burs over the osseous tissue it was used eight dogs, made in the lower jaw holes to place the implants following the sequence of burs suggested by manufacturers After the holes were made the osseous fragments were removed and made semiseriate .incisions of 6 JlIIl following the long axis of the holes and stained with heinatoxiline and eosine A microscopic avaluation showed sharp incision, few necrosis area and bone fragments meaning that applied technique was adequated and proving the quality of the burs / Mestrado / Mestre em Odontologia
4

Instrumentos cortantes rotatorios : estudo das variações termicas ocorridas na camara pulpar, durante o corte dos tecidos duros dos dentes

Consani, Simonides, 1939- 20 July 2018 (has links)
Orientador: Luiz Antonio Ruhnke / Tese (doutorado) - Universidade de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T14:26:27Z (GMT). No. of bitstreams: 1 Consani_Simonides_D.pdf: 2980475 bytes, checksum: 8f2d9ca8524be1e2433432939bf937a8 (MD5) Previous issue date: 1968 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Dentística Operatoória / Doutor em Ciências
5

Efeito do tempo de fotoativação na resistência de união ao cisalhamento de bráquetes metálicos e cerâmicos à superfície cerâmica

Carvalho, Marcela Batista Pereira de 28 August 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade em Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-11-19T15:44:37Z No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-12-04T10:33:26Z (GMT) No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Made available in DSpace on 2013-12-04T10:33:26Z (GMT). No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / O objetivo do presente estudo foi avaliar a resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica, analisando dois tempos de fotoativação com aparelho LED (light emitting diode). O ensaio de resistência de união foi realizado em bráquetes de aço inoxidável (Morelli), cerâmicos monocristalinos (Inspire ICE) e cerâmicos policristalinos (InVu). Os discos cerâmicos (IPS Empress Esthetic) incluídos em cilindros de resina acrílica foram condicionados com ácido fluorídrico gel a 10% por 60 segundos. Após a aplicação de silano, por 30 segundos, os bráquetes foram colados seguindo o protocolo recomendado para o compósito Transbond XT. Os corpos-de-prova, para cada tipo de bráquete, foram distribuídos aleatoriamente em 2 grupos (n=15) conforme o tempo de fotoativação, de 20 e 10 segundos, usando o aparelho LED Bluephase. Todos os corpos-de-prova foram armazenados a 37°C e 100% de umidade por 24 horas, posteriormente, termociclados (1000 ciclos, de 5°C à 55°C) e retornaram ao ambiente úmido de armazenamento. O teste de cisalhamento foi realizado após 24 horas na máquina universal de ensaio a uma velocidade de 1 mm/min. Em seguida, o Índice Remanescente de Adesivo (IRA) foi avaliado. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (5%). Todos os bráquetes fotoativados por 20 segundos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes fotoativados por 10 segundos. Os bráquetes cerâmicos monocristalinos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes cerâmicos policristalinos e de aço inoxidável, sendo estes, estatisticamente semelhantes (p>0,05) quando fotoativados por 20 segundos. Para o tempo de fotoativação de 10 segundos, os bráquetes cerâmicos policristalinos apresentaram valores superiores (p<0,05) aos de aço inoxidável. Enquanto nos grupos de 20 segundos de tempo de fotoativação, o escore 1 (IRA) foi observado com predominância para os bráquetes de aço inoxidável e cerâmicos monocristalinos, e o escore 3 para o bráquete cerâmico policristalino, nos grupos de 10 segundos, o bráquete cerâmico monocristalino apresentou predominância do escore 1, e escore 3 para os bráquetes de aço inoxidável e cerâmicos policristalinos. Pôde-se concluir que o tempo de fotoativação teve influência significativa na resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica e que os bráquetes cerâmicos monocristalinos apresentaram os maiores valores de resistência de união. ______________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the bond strength of metallic and ceramic brackets bonded to ceramic, by testing two photoactivation times using a LED (light emitting diode) curing unit. Bond strength testing was performed on stainless steel brackets (Morelli), monocrystalline ceramic brackets (Inspire ICE), and polycrystalline ceramic brackets (InVu). Disc-shaped-ceramic specimens (IPS Empress Esthetic) embedded in acrylic resin blocks were etched with 10% hydrofluoric acid gel for 60 seconds. After application of silane for 30 seconds, brackets were bonded following the protocol recommended for Transbond XT. Specimens for each bracket type were assigned to two groups (n=15), according to the photoactivation times: 20 seconds or 10 seconds, using a Bluephase LED unit. All specimens were stored at 37°C and 100% relative humidity for 24 hours, then thermocycled (1,000 cycles, 5°C to 55°C), and they returned to the humid storage conditions. Shear bond testing was carried out after 24 hours with a universal testing machine at a crosshead speed of 1-mm/min. Adhesive Remnant Index (ARI) scores were evaluated. Data were subjected to two-way ANOVA and Tukey's test. All bracket types photoactivated for 20 seconds showed significantly (p<0.05) higher bond strength compared to specimens photoactivated for 10 seconds. Monocrystalline brackets showed significantly (p<0.05) higher bond strength compared to polycrystalline and stainless steel brackets, which are statistically similar (p>0,05) when photoactivated for 20 seconds. For 10 seconds photoactivation time, the polycrystalline ceramic brackets showed higher values (p<0.05) than stainless steel brackets. For the 20 second photoactivation time group, an ARI score 1 was observed with predominance for SS and monocrystalline brackets, and score 3 for polycrystalline brackets; for the 10 second photoactivation time group, an ARI score 1 was observed with predominance for the monocrystalline brackets, and score 3 for stainless steel and polycrystalline brackets. In conclusion, photoactivation time had significant influence on the bond strength of metallic and ceramic brackets bonded to a ceramic surface, and monocrystalline brackets showed the highest bond strength values.
6

Concepção morfológica de fórceps, para intervenção no paciente em posição supina e o operador sentado /

Naressi, Wilson Galvão. January 1997 (has links)
Banca: Antenor Araújo / Banca: Nemre Adas Saliba / Banca: Jaime Renato Furquim de Castro / Banca: Renato Luis Ference / Banca: Roberto Antonio Nicodemo / Resumo: A Ergonomia, ciência da racionalização do trabalho, busca o total entrosamento do homem e seus instrumentos de trabalho. Em Odontologia, a Ergonomia se faz presente no ato do profissional trabalhar corretamente sentado, em situação de conforto funcional, intervindo em paciente na posição supina, contando com equipamento e instrumental adequadamente concebidos. Atualmente, o equipamento odontológico está devidamente racionalizado; no entanto, determinados instrumentos necessitam ser redesenhados, para melhor se ajustarem àqueles requisitos. O projeto de um instrumento manual deve permitir manejo cômodo, firme e seguro. Devem-se considerar detalhes anatômicos, posição correta do operador quando da intervenção e características específicos de utilização. O instrumento ora em análise - fórceps para molares inferiores - foi concebido dentro desses requisitos, em conjunto com novo sistemática de exodontia via alveolar, consubstanciada em estudos eletromiográficos e biomecânicos. A morfologia do instrumento, que possibilita cinético simples e natural do operador, foi obtida por mudança no paradigma dos instrumentos de ação cruzado convencionais (cuja apreensão ocorre sobre as hastes), desvinculando-se o "cabo" do "braço da hoste". Isto induziu a concepção anatômica de empunhaduras perpendiculares às extremidades das hastes, resultando em instrumento eficiente e eficaz, conforme indicado em sua fase de experimentação / Abstract: Ergonomics, the science of working rationalization, seeks the best relationship between man and his working tools. In Dentistry, ergonomics is present as for the professional working correctly seated, in functional comfort, intervening of supine position patient, by means of suitable equipment and instrument. Nowadays, dental equipment is justly rationalized; however, some instruments should take shape, in order to adapt those requirements. The hand tool design should permit a comfortable, non-slip and safe handling. Thus, anatomical details, the correct position of the operator for its use and specific characteristics of application should be taken into account. The instrument under analysis - forceps - was conceived according to these requirements along with a new alveolar tooth extraction technique, based on electromyographic and biomechanical studies. The morphology of the instrument, which makes possible a simple and natural kinetics of the operator, was obtained by changing the paradigm of the conventional cross-action instruments (whose grip is always on the arms of the tool), divesting the "handle" from the "tool arm". This induced on anatomical conceiving of perpendicular handles to the extremity of the tool arm, resulting an efficient and effective instrument, according to indicated on its experimental phase
7

Degradação de brackets ortodônticos no meio bucal e sua relação com a fricção = Biodegradation of orthodontic metallic brackets and associated implications for friction / Saulo Regis de Oliveira Junior ; orientador, Hiroshi Maruo ; Paulo Soares / Biodegradation of orthodontic metallic brackets and associated implications for friction

Oliveira Junior, Saulo Regis de January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / A exposição in vivo pode promover alterações significativas nos biomateriais metálicos, e consequente prejuízo do seu desempenho funcional. objetivou-se avaliar e comparar a morfologia, dimensões e resistência friccional de brackets ortodônticos metálico / In vivo exposure may promote significant alterations in metallic biomaterials, with consequent impairment of their clinical performance. This study aimed to assess and compare the surface morphology, dimensions and frictional behavior of as-received and r
8

Avaliação do efeito da afiação com diferentes técnicas sobre o ângulo de corte de curetas de Gracey

Andrade Acevedo, Roberto Antonio [UNESP] 18 August 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-08-18Bitstream added on 2014-06-13T19:04:27Z : No. of bitstreams: 1 andradeacevedo_ra_dr_arafo.pdf: 2469845 bytes, checksum: 6aef2f449ff6364a09cca9dd4566f240 (MD5) / O presente trabalho teve por objetivo avaliar em fotomicrografias obtidas em microscópio eletrônico de varredura (MEV) o ângulo de corte de curetas de Gracey 5-6 em três níveis: afiação de fábrica, após ficarem sem corte e após serem reafiadas utilizando nove diferentes técnicas padronizadas de afiação: 1- face lateral da cureta contra a pedra Arkansas plana; 2- face coronal e posteriormente a lateral contra a pedra Arkansas plana; 3- pedra de Arkansas plana contra a face lateral da cureta; 4- cone de óxido de alumínio a baixa rotação contra a face coronal e em seguida a face lateral da cureta; 5- face lateral da cureta com pedra Arkansas 299; 6- face lateral da cureta com o aparelho padronizador Hu-Friedy; 7- face coronal da cureta com ponta de videa; 8- face coronal da cureta com ponta de videa e em seguida a face lateral com pedra de Arkansas plana; 9- afiação da face coronal com ponta de videa e em seguida pó abrasivo e roda de feltro rotatória na face lateral da cureta. Foram tomadas fotomicrografias (350X) do ângulo de corte e posteriormente avaliadas por um examinador calibrado através do índice do ângulo de corte. A analise estatística de Kruskal Wallis e comparações múltiplas mostraram que as técnicas 1 e 2 foram as melhores técnicas de afiação seguidas das técnicas 6, 5 e 8. As piores técnicas foram a 7, 9, 4, 0 e 3. A reafiação da face coronal das curetas produziu a formação de projeções metálicas não funcionais no ângulo de corte e finalmente não houve diferenças entre a afiação do extremo par e ímpar dos instrumentos em nenhuma das técnicas de afiação utilizadas. / A micrographs obtained by a scanning electron microscope (SEM) were used to evaluated the gracey 5-6 cutting edges as the come from manufacture, after they had been dull and after they were resharpened by several standard techniques: 1- lateral surface over a flat Arkansas sharp stone; 2- coronal surface and the a lateral surface over a flat Arkansas sharp stone; 3- lateral surface by passing a flat Arkansas sharp stone; 4- rotatory aluminum oxide stone over a coronal surface and then over a lateral face; 5- lateral surface by passing an Arkansas 299 stone; 6- lateral surface on Hu-Friedy sharp divice; 7- coronal surface by a Whittler Neivert Device; 8- coronal face by a Whittler Neivert Device and the a lateral surface over a flat Arkansas sharp stone; 9- coronal surface with a Whittler Neivert Device and a rotating, impregnated, felt wheel on the lateral surface. The cutting edges was blindly evaluated on micrographs (X350) by one calibrated examiner (cutting angle index). A statistical analysis showed that techniques 1 and 2 were the best ones followed by a 6, 5 and 8 techniques. The worst techniques were a 7, 9, 4, 0 and 3. Resharpened on the coronal face of curettes generated a non functional wire edges on the cutting edge angle and there were not differences between the paired and unpaired extreme of the instruments resharpened.
9

Influência de diferentes técnicas de instrumentação no travamento e adaptação de cones de guta-percha .O4 analisados por tomografia computadorizada /

Vasconcelos, Rafaela Andrade de. January 2012 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Ana Paula Martins Gomes / Banca: Norberti Bernardineli / Resumo: O objetivo deste estudo foi avaliar a influência de diferentes técnicas de instrumentação no travamento e adaptação do cone de guta-percha .04 em canais radiculares. A avaliação foi realizada observando o local onde o cone entrava em contato com o maior número de paredes internas do canal radicular através da tomografia computadorizada de feixe cônico (TCFC). Foram utilizados 105 dentes humanos unirradiculados, divididos em 7 grupos de instrumentação (n=15): híbrida oscilatório + Manual (OM); Manual (M); Protaper Universal (P); híbrida oscilatório + Protaper (OP); Mtwo (MT); híbrida oscilatório + Mtwo (OMT); Reciproc (R). Finalizadas as instrumentações, o travamento do cone .04 foi realizado 1mm aquém do ápice sendo conferido com uma radiografia digital. As imagens tomográficas foram adquiridas através do TCFC ICat e realizadas nos cortes frontal, sagital e transversal através do software Xoran. Os dados foram submetidos à análise estatística de comparação das proporções via teste "Z" da curva normal, teste Exato de Fisher e quando necessário teste Qui-quadrado. Os resultados apresentaram 100% de travamento do cone no terço apical em todas as instrumentações. A adaptação do cone nas quatro paredes do canal apresentou uma variação de 26,67% (OMT e P) a 73,33% (MT) havendo diferença estatística entre esses grupos (pvalor = 0,027 < 0,05). Em todos os tipos de instrumentação as paredes que apresentaram menor contato foram as vestibulares e as linguais. Os valores médios de área sem contato do cone variaram de 0,06mm2 (MT) a 0,41mm2 (OMT). Concluiu-se que as técnicas de instrumentação podem influenciar no travamento do cone quanto ao número de paredes contactadas ao canal, e também, ao valor de área em que o cone não se adapta ao canal, e não influenciam no nível de travamento do cone / Abstract: The aim of this study was to assess the influence of different instrumentation techniques on the adaptation of .04 gutta-percha points into root canals. The assessment was performed at areas of greater contact of gutta-percha to root canal walls, by means of cone-beam computed tomography. One hundred and five uniradicular human teeth were used. Teeth were divided into 7 groups according to instrumentation (n=15) technique: hybrid oscillatory+Manual (OM); Manual (M); Protaper Universal (P); hybrid oscillatory+Protaper (OP); Mtwo (MT); hybrid oscilatory+Mtwo (OMT); Reciproc (R). Gutta-percha point was adapted 1mm from apex and confirmed by digital radiography. Tomographic images were obtained through CFCT Icat (imaging Science International, USA) and analyzed at the frontal, sagittal and transversal planes by means of Xoran software (Xoran Technologies, USA). Data were submitted to statistical Z test for normal distribution, Exact Fisher test, and Chi-square when necessary. Results: One hundred percent of points were adapted at the apical third of the roots for every instrumentation procedures. The adaptation of points at the four canal walls varied from 26.67% (OMT and P) to 73.33% (MT), with statistical differences among the groups (p = 0,027). The buccal and lingual walls presented the lowest contact of point for all instrumentation procedures. The mean average wall areas without contact varied from 0.06mm2 to 0.41mm2(OMT). It was concluded that different instrumentation techniques might influence the adaptation of gutta-percha points in relation to the number of walls contacted, as well as in relation to the wall area not adapted to the guttapercha point, and no influence in adaptation level / Mestre
10

Influência de diferentes técnicas de instrumentação no travamento e adaptação de cones de guta-percha .O4 analisados por tomografia computadorizada

Vasconcelos, Rafaela Andrade de [UNESP] 06 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-06Bitstream added on 2014-06-13T20:40:08Z : No. of bitstreams: 1 vasconcelos_ra_me_sjc.pdf: 479818 bytes, checksum: 9f3f754b2f47e390a6321179a6a8e7da (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência de diferentes técnicas de instrumentação no travamento e adaptação do cone de guta-percha .04 em canais radiculares. A avaliação foi realizada observando o local onde o cone entrava em contato com o maior número de paredes internas do canal radicular através da tomografia computadorizada de feixe cônico (TCFC). Foram utilizados 105 dentes humanos unirradiculados, divididos em 7 grupos de instrumentação (n=15): híbrida oscilatório + Manual (OM); Manual (M); Protaper Universal (P); híbrida oscilatório + Protaper (OP); Mtwo (MT); híbrida oscilatório + Mtwo (OMT); Reciproc (R). Finalizadas as instrumentações, o travamento do cone .04 foi realizado 1mm aquém do ápice sendo conferido com uma radiografia digital. As imagens tomográficas foram adquiridas através do TCFC ICat e realizadas nos cortes frontal, sagital e transversal através do software Xoran. Os dados foram submetidos à análise estatística de comparação das proporções via teste “Z” da curva normal, teste Exato de Fisher e quando necessário teste Qui-quadrado. Os resultados apresentaram 100% de travamento do cone no terço apical em todas as instrumentações. A adaptação do cone nas quatro paredes do canal apresentou uma variação de 26,67% (OMT e P) a 73,33% (MT) havendo diferença estatística entre esses grupos (pvalor = 0,027 < 0,05). Em todos os tipos de instrumentação as paredes que apresentaram menor contato foram as vestibulares e as linguais. Os valores médios de área sem contato do cone variaram de 0,06mm2 (MT) a 0,41mm2 (OMT). Concluiu-se que as técnicas de instrumentação podem influenciar no travamento do cone quanto ao número de paredes contactadas ao canal, e também, ao valor de área em que o cone não se adapta ao canal, e não influenciam no nível de travamento do cone / The aim of this study was to assess the influence of different instrumentation techniques on the adaptation of .04 gutta-percha points into root canals. The assessment was performed at areas of greater contact of gutta-percha to root canal walls, by means of cone-beam computed tomography. One hundred and five uniradicular human teeth were used. Teeth were divided into 7 groups according to instrumentation (n=15) technique: hybrid oscillatory+Manual (OM); Manual (M); Protaper Universal (P); hybrid oscillatory+Protaper (OP); Mtwo (MT); hybrid oscilatory+Mtwo (OMT); Reciproc (R). Gutta-percha point was adapted 1mm from apex and confirmed by digital radiography. Tomographic images were obtained through CFCT Icat (imaging Science International, USA) and analyzed at the frontal, sagittal and transversal planes by means of Xoran software (Xoran Technologies, USA). Data were submitted to statistical Z test for normal distribution, Exact Fisher test, and Chi-square when necessary. Results: One hundred percent of points were adapted at the apical third of the roots for every instrumentation procedures. The adaptation of points at the four canal walls varied from 26.67% (OMT and P) to 73.33% (MT), with statistical differences among the groups (p = 0,027). The buccal and lingual walls presented the lowest contact of point for all instrumentation procedures. The mean average wall areas without contact varied from 0.06mm2 to 0.41mm2(OMT). It was concluded that different instrumentation techniques might influence the adaptation of gutta-percha points in relation to the number of walls contacted, as well as in relation to the wall area not adapted to the guttapercha point, and no influence in adaptation level

Page generated in 0.1425 seconds