• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 30
  • 8
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 138
  • 138
  • 82
  • 33
  • 27
  • 26
  • 26
  • 25
  • 20
  • 19
  • 12
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da eficiência de corte de fresas Carbide em função dos métodos de esterilização físicos e químico. Análise gravimétrica

Fais, Laiza Maria Grassi [UNESP] 28 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-28Bitstream added on 2014-06-13T19:16:50Z : No. of bitstreams: 1 fais_lmg_me_arafo.pdf: 941714 bytes, checksum: 824ebe7862b6ae859b4471c0b54f2cb3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito de métodos de esterilização físicos e químico sobre a eficiência de corte de fresas carbide. Sessenta fresas da marca S.S. White foram utilizadas para o desgaste de vidro (30 mm X 30 mm X 10 mm) e divididas em cinco grupos experimentais em função do tratamento realizado: E1 - esterilização em autoclave, E2 - esterilização em estufa, E3 - esterilização em forno de microondas, E4 - esterilização em substância química e E0 - ausência de esterilização (controle). Com o auxílio de um aparelho padronizador de desgaste, as fresas foram utilizadas para o desgaste do vidro em um total de 30 minutos divididos em doze períodos de 2,5 minutos. Após cada 2,5 minutos de uso, as fresas foram limpas com escova de nylon sob água corrente e secas com jatos de ar e, em seguida, submetidas as seus respectivos tratamentos. A eficiência de corte das fresas foi determinada pela perda de massa do vidro, que teve sua massa aferida antes e após cada período de desgaste. A soma ( ? ) da quantidade de desgaste realizado por cada fresa após os 12 ciclos de uso foi calculada e utilizada para se determinar a eficiência de corte após 30 minutos de uso. Os valores da ? foram submetidos à análise estatística pelos testes de Kruskal-Wallis e de Dunn. Diferenças estatisticamente significantes entre os grupos experimentais foram verificadas (p<0,05). De acordo com os resultados, entre os métodos de esterilização avaliados, o uso o calor seco foi responsável pelo melhor desempenho das fresas, ao contrário da utilização de glutaraldeído, que foi considerado o pior método de esterilização. / The aim of this study was to evaluate the influence of physical and chemical sterilization methods on the cutting effectiveness of carbide burs. Sixty S.S. White burs were used to cut glass plates (30 mm X 30 mm X 10 mm) and subjected to the following procedures: S1 - sterilization by autoclave; S2 - sterilization by dry heat; S3 - sterilization by microwave irradiation; S4 - sterilization by chemical substance and S0 - no sterilization (control group). The burs were used to cut glass plates in a cutting machine for twelve 2.5-minute periods. After each period, the burs were cleaned with a nylon brush under running water, dried with air spray (40 seconds), and then subjected to their procedures respectively. The cutting effectiveness was calculated by the weight loss of the glass which was weighed before and after each 2.5-minute period. The sum ( ? ) of the cutting amount performed by each bur after twelve cycles of use were calculated and used to determine the cutting effectiveness after 30 minutes of use. The ? values were statistically analyzed by Kruskal-Wallisþs and Dunnþs tests. Statistical differences among the experimental groups were observed (p <.05). According to the results, among the sterilization methods, the use of dry heat was responsible for the best carbide burs performance and, the use of glutaraldehyde was responsible for the worst burs performance.
112

Análise morfológica e de resistência à flexão da interface ponta ativa/haste metálica em fresas carbide após o uso de esterilização

Marcelo, Caroline Canhizares [UNESP] 30 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-30Bitstream added on 2014-06-13T20:58:44Z : No. of bitstreams: 1 marcelo_cc_me_arafo.pdf: 1311971 bytes, checksum: fdcda6bc30a1c9aa0d3eea636033a85a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Na prática odontológica os rigores de controle de infecção exigem do cirurgião-dentista procedimentos de esterilização e desinfecção sobre seus instrumentos para prevenir a infecção cruzada, porém, esses procedimentos podem levar à oxidação e, portanto, determinar o aparecimento de corrosão nos instrumentos rotatórios cortantes. Considerando as questões que têm sido levantadas sobre o efeito dos vários métodos de esterilização sobre a eficiência de corte e resistência dos instrumentos dentais, este trabalho teve como objetivo avaliar possíveis alterações morfológicas e também alterações na resistência de união ocorridas entre a ponta ativa/ haste metálica em fresas carbide causadas pelo uso e procedimentos de esterilização. Para tanto foram utilizadas 130 fresas carbide que foram divididas em grupos de acordo com o tratamento aplicado: controle, autoclave, estufa, microondas e glutaraldeído. Depois de completado o teste experimental proposto, todos os grupos foram submetidos ao teste de resistência à flexão. Foi realizada também análise morfológica (qualitativa) das fresas por fotomicrografias capturadas por meio de uma lupa estereoscópica LEICA com o software. Os dados foram devidamente anotados e submetidos à análise estatística com testes de Kruskal-Wallis e Dunn. Os resultados, tanto da avaliação morfológica quanto da resistência à flexão, mostraram que somente o grupo do glutaraldeído se comportou de maneira diferente do grupo controle, havendo diferença estatística significante entre esses dois grupos. E, os demais grupos foram estatisticamente semelhante ao grupo controle. Pode-se concluir que nenhum método físico de esterilização estudado (autoclave, estufa e microondas) influenciou negativamente as características morfológicas e a resistência de união da interface ponta ativa/haste metálica... / Such as in all professions related to health, in dentistry there are necessary procedures which limit or obstruct disease propagation through clinical practice. Among such procedures is the sterilization of rotary instruments to prevent the risk of cross-infection. Each day in clinical practice, physical and chemical methods of sterilization can corrode appearance. The presence of corrosion on rotary cutting instruments makes them unusable. Concerning questions that have been raised on effect of some sterilization methods on the cutting efficiency and dental instruments resistance, this paper aimed to evaluate the influence of cutting time, sterilization methods and the amount of sterilization cycles in morphologic alterations and fracture resistance between the cutting head/ steel shank of carbide burs. An in vitro study was carried out in which one hundred-thirty tungsten-carbide burs were divided into five groups in accordance with sterilization method: control; autoclave; dry heat; microwave and glutaraldehyde. Glass plates were cut for 2.5 minutes by each bur attached to a high-speed handpiece with an intermittent load of 0.68N. After cutting time, burs were cleaned, dried, and submitted to a sterilization method corresponding to each group. Each cutting time or sterilization cycles, the visual accompaniment of the burs and photographed under a stereomicroscope. All groups were submitted to the flexure strength test at the end of a stipulated time in the mechanical rehearsals machine, MTS. Results obtained were submitted to the Kruskal-Wallis test and Dunn, which showed that only the group of glutaraldeído had difference significant statistics of the control group and the another groups (autoclave, dry heat and microwave) had been statistical similar to the control group, in both the morphologic evaluation and the fracture resistance. It may be... (Complete abstract, click electronic access below)
113

Esterilização de pontas diamantadas através da energia por microondas

Farias, Renata Jansen de Mello [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:58:47Z : No. of bitstreams: 1 farias_rjm_me_arafo.pdf: 2603163 bytes, checksum: eae9bc73d5b2ac8f609dd5777386f26d (MD5) / Tendo em vista a importância e necessidade de esterilização dos instrumentos cortantes rotatórios usados em odontologia, associada à indispensável agilidade nos atendimentos e, considerando ainda, a escassez de publicações atuais voltadas para este tema, julgou-se válida a preocupação em estudar a efetividade do método de esterilização através da energia por microondas em pontas diamantadas. Para tal, oitenta e uma pontas diamantadas foram contaminadas em uma suspensão bacteriana formada por bactérias pertencentes ao meio bucal (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divididas em três diferentes grupos e submetidas à irradiação por microondas em forno de microondas doméstico na potência máxima (800 W). Os grupos foram diferenciados entre si conforme o método de acondicionamento dos corpos-de-prova (2) e o procedimento para esterilização (3). No Procedimento de esterilização P1, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados em placas de Petri contendo 40 mL de água e submetidos à irradiação por microondas nos períodos de 0, 1, 2 e 3 minutos. No Procedimento de esterilização P2, os corpos-de-prova foram envolvidos em folha de poliéster, acondicionados em envelopes para esterilização e expostos à energia por microondas nos períodos de 0, 2, 4, 5 e 6 minutos, sem sofrerem previamente o procedimento de limpeza. E no Procedimento de esterilização P3, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados e submetidos à irradiação conforme o método anterior. A esterilização foi obtida tanto no Procedimento P1, no período de um minuto, quanto no Procedimento P3, no período de 6 minutos. Portanto, pudemos concluir... / Concerning the importance and the need for sterilization of the rotary cutting instruments used in dentistry, associated to the indispensable agility in the appointments and, considering also the scarceness of updated publications in regard to this theme, the preoccupation in studying the effectiveness of the sterilization method by the energy of microwaves in diamond burs was judged valid. To perform such study, eighty-one diamond burs were contaminated in a bacterial suspension formed by bacteria which belong to the oral environment (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divided in three different groups and submitted to irradiation by microwaves in a domestic microwave oven on maximum power (800 W). The groups were discriminated according to the method of packing of the specimens (2) and the procedure for sterilization (3). In the procedure for sterilization 1, the specimens were cleaned with steel sponge in water, packed in Petri dishes containing 40 mL of water and submitted to irradiation by microwaves in the periods of 0, 1, 2 and 3 minutes. In the procedure for sterilization 2, the test specimens were wrapped in a polyester sheet, packed in envelopes for sterilization and exposed to energy by microwaves in the periods of 0, 2, 4, 5 and 6 minutes, without going through the cleaning procedure previously. Finally, in the procedure for sterilization 3, the test specimens were cleaned with steel sponge in water, packed and submitted to irradiation according to the anterior method. The sterilization was obtained both in procedure 1, in the period of 1 minute, and in procedure 3, in the period of 6 minutes. Therefore, we could conclude that ...(Complete abstract, click electronic access below)
114

Esterilização de fresas carbide em fornos de micro-ondas domésticos. Efeito da capacidade. da potência, do meio da imersão, da quantidade e posição da amostra sobre o tempo de esposição /

Pita, Ana Paula Gonçalves. January 2009 (has links)
Resumo: O uso do forno de micro-ondas para a esterilização tem sido proposto em diferentes áreas. O tempo da exposição necessário para esterilizar água deionizada contaminada em diferentes posições dentro do forno foi avaliado e um método da esterilização de fresas carbide foi avaliado, considerando sua imersão ou não em 2 ml e 10 ml de água ou o óleo, a capacidade do forno (27 e 38 l), o nível de potência (400 e 600 W) e diferentes quantidades de instrumentos irradiados ao mesmo tempo (1, 5 e 10 fresas). Este trabalho foi feito em três etapas consecutivamente. Primeiramente, 10 ml da água deionizada foi contaminada por um dos três micro-organismos (Bacilus subtilis, Escherichia coli, Cândida albicans). A amostra contaminada foi situada em uma das 15 posições determinadas pela combinação das posições horizontais (anterior, posterior, direita, esquerda e central) e das posições verticais (sobre o prato giratório, 3 cm ou 5 cm acima do prato giratório) e foi submetida à irradiação por microondas (580 W) por 0,5, 1, 2, 5, 6, 7 ou 8 minutos. Nas etapas subseqüentes, as fresas estéreis foram contaminadas individualmente pelos mesmos micro-organismos. Após a contamindação, foram individualmente submetidas à irradiação (580 W) por 1, 2, 3, 4, 8, 9, 16, 17 ou 20 min em um frasco vazio ou contendo 2 ou 10 ml de água ou de óleo mineral. Na última etapa, os instrumentos contaminados foram irradiados individualmente ou nos grupos (5 ou 10 fresas), a aproximadamente 400 ou 600 W, em um dos dois fornos (27 ou 38 l) durante: 0,5; 1; 2; 3; 4; 5; 6; 8; 9.5; 10; 11; 13 ou 14,5 minutos. Após a irradiação foram adicionados 10 ml de meio fluido no frasco contendo os espécimes irradiados, que foram incubados a 37°C durante 48 h (B. 11 subtilis e E. coli) ou a 28ºC durante 72 h (C. albicans) para avaliação do efeito da esterilização pela turvação do caldo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of microwave oven for sterilization has been proposed in different fields. The exposition time required to sterilize contaminated deionized water in different positions was evaluated and a microwave sterilization method of dental carbide burs was tested considering their immersion or not in 2 ml or 10 ml of water or oil, the oven capacities (27 l and 38 l), the level power (400 and 600 W) and different amount of instruments irradiated at the same time (1, 5 and 10 burs). This work was done in three stages consecutively. First, 10 ml of deionized water were inoculated with three microorganisms (Bacilus subtilis, Escherichia coli, Candida albicans). The contaminated sample was located at one of the 15 positions determined by the combination of horizontal positions (anterior, posterior, right, left, centre) and vertical positions (on the glass plate, 3 cm over the glass plate level, 5 cm over the glass plate level) and microwaved (580 W) for 0.3, 1, 2, 5, 6, 7 or 8 minutes. In the subsequent stages, sterile burs were individually inoculated with the same microorganisms. The contaminated burs were microwaved at 580 W for 1, 2, 3, 4, 8, 9, 16, 17 or 20 min in the dry state or immersed in 2 or 10 ml of water or mineral oil. In last stage, the contaminated instruments were microwaved individually or in groups (5 or 10 burs), at approximately 400 or 600 W, into the two ovens for: 0,5; 1; 2; 3; 4; 5; 6; 8; 9,5;10; 11; 13 or 14,5 minutes. After irradiation sterile broth was added into the flask containing irradiated specimens and incubated at 37°C for 48h (B. subtilis and E. coli) or at 28ºC for 72h (C. albicans), the sterilization effect was verified by the turbidity test. This study suggests that the position of the sample must be considered in domestic microwaves ovens sterilization methods and the central position should be avoided. The presence of a liquid material in contact... (Complete abstract click electronic access below) / Orientador: Gelson Luis Adabo / Coorientador: Regina Helena B. T. da Silva / Banca: Ligia Antunes Pereira Pinelli / Banca: Luis Geraldo Vaz / Banca: Taís Maria Bauab / Banca: Flávia Magnani Bevilacqua / Doutor
115

Desvio, capacidade de centralização e fadiga cíclica promovidos por instrumentos TF Adaptive e Navigator EVO, em diferentes cinemáticas

Duarte, Pedro Henrique Marks January 2017 (has links)
Introdução: A evolução dos instrumentos de NiTi pode ser dividida em gerações de acordo com algumas modificações tais como: tratamento térmico da liga, secção transversal e movimento utilizado para o preparo do canal, que pode ser movimento rotatório contínuo ou movimento oscilatório assimétrico. Essas mudanças tem como objetivo prover maior flexibilidade aos instrumentos, permitindo uma melhor modelagem do canal, com menor desvio e menor risco de perfurações. Outro aspecto relevante é a maior resistência à fadiga cíclica, das ligas com tratamento térmico, colaborando para uma maior resistência à fratura do instrumento. Objetivos: Este estudo comparou a fadiga cíclica, o transporte do canal , a capacidade de centralização e o volume do canal pós preparo, produzidos pelos sistemas TF Adaptive e Navigator EVO, quando utilizados em rotação contínua ou no movimento Adaptive. Métodos: Quarenta raízes mésio-vestibulares de molares superiores foram analisadas através de micro-CT antes e depois do preparo do canal radicular com os dois sistemas e dois movimentos (Adaptive e Rotação Contínua). As amostras foram divididas em quatro grupos: TFA – instrumentos TF Adaptive utilizados no movimento Adaptive; TFC –instrumentos TF Adaptive utilizados em rotação contínua; NA – instrumentos Navigator EVO utilizados no movimento Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Os canais radiculares foram preparados até instrumentos 35.04. O transporte apical, a capacidade de centralização e o volume de preparo foram analisados utilizando-se micro-CT em três níveis: 3, 6 e 9mm do ápice.O teste de fadiga cíclica foi realizado utilizando um equipamento apropriado, onde, dez instrumentos de cada marca foram utilizados em um contraângulo redutor 6:1 e um motor elétrico com controle de torque, com programas prédefinidos ‘‘custom mode'' e ‘‘TF Adaptive'' para ativar os instrumentos 25.06 e 35.04.Os resultados foram analisados com os testes Kruskal-Wallis eDunn para se verificar o transporte do canal, a capacidade de centralização e o volume do canal. O teste Student-T foi usado para avaliar a fadiga cíclica (P = 0,05). Conclusões: Ambos sistemas podem ser usados no movimento Adaptive ou em rotação contínua. Porém, a resistência à fratura dos instrumentos foi maior quando utilizados em rotação contínua. Pouco transporte de canal ocorreu, quando os canais mésio-vestibulares de molares superiores foram preparados até instrumentos 35.04. / Introduction: The evolution of NiTi instruments can be divided in generations, according to changes like in the NiTi alloy, heat treatment, cross-section format, and in the movement used for root preparation that goes form continuous rotation to asymmetric oscillation. These changes aim to provide greater flexibility to the instruments, allowing a better shaping, with less transportation and risk of perforation. Other aspect is the increased fracture resistance of the alloys with heat treatment, which is a big concern about NiTi instruments. Aim: This study compared the cyclic fatigue and the canal transportation promotedby TF Adaptive and Navigator EVO systems when used with two different motions. Methods: Forty mesiobuccal roots of maxillary molars were scanned using micro-CT imaging before and after root canal preparation with the two instrument systems two motions (adaptive and continuous rotation). Samples were divided into four groups: TFA – TF Adaptive instruments under adaptive motion; TFC - TF Adaptive instruments under continuous motion; NA - Navigator instruments under adaptive motion; and NC – Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation, centering ability and volume were analyzed using micro- CT at three levels: 3, 6 and 9 mm from the apex. The cyclic fatigue tests were performed using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs ‘‘custom mode'' and ‘‘TF Adaptive'' to activate25.06 and 35.04 instruments. Data were analyzed with Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability and canal volume. Student-T test was used to evaluate cyclic fatigue (P = .05). Conclusions: Both systems can be used under adaptive or continuous rotation. However; the lifespan of the instruments was higher when used under continuous rotation. Little canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04instruments.
116

Análise radiográfica da modelagem de canais radiculares ovalados realizada com sistemas rotatórios de níquel-titânio

Croti, Hugo Ricardo [UNESP] 17 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-17Bitstream added on 2014-06-13T20:52:12Z : No. of bitstreams: 1 croti_hr_me_arafo.pdf: 544040 bytes, checksum: d55f28cedd7d02980be27c23a1acf63b (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi analisar radiograficamente a modelagem de canais radiculares ovalados realizada com três sistemas rotatórios de níqueltitânio. Foram utilizados 60 incisivos inferiores inseridos em blocos acrílicos, que acoplados a um sistema de plataforma radiográfica, permitiu a obtenção de imagens antes e após o preparo biomecânico, em sentido mésio-distal e vestíbulo-lingual. Um meio de contraste radiológico foi utilizado para preenchimento dos canais radiculares, proporcionando visualização mais adequada destes nas imagens radiográficas. Para o preparo biomecânico, os dentes foram divididos em três grupos (n=20), numericamente equivalentes, de acordo com o sistema rotatório utilizado. O grupo I foi instrumentado com o sistema Protaper Universal, tendo os instrumentos modeladores acionados em brushing motion e como último instrumento empregado para o preparo apical o F3. O grupo II foi instrumentado com o sistema Race, tendo os instrumentos Pré-Race acionados em brushing motion e como último instrumento empregado no preparo apical o #30/0,06. O grupo III foi instrumentado com o sistema K3, tendo todos os instrumentos acionados em pecking motion e como último instrumento utilizado no preparo apical o #30/0,06. As radiografias periapicais, contendo as imagens antes e após o preparo biomecânico, em ambos os sentidos, foram processados automaticamente e digitalizados em um scanner de plataforma. As imagens resultantes foram arquivadas no programa Adobe Photoshop 7.0 e importadas para o software Image tool 3.0. Avaliou-se o aumento percentual de área dos canais radiculares nos terços cervical, médio e apical, resultante em cada grupo experimental, nos sentidos mésio-distal e vestíbulo-lingual. / The aim of this study was radiographically analyze the shaping of oval root canals obtained by utilization of three nickel-titanium rotary systems. It was conducted on 60 mandibular incisors embedded in acrylic blocks and connected to a radiographic platform system for achievement of images, before and after biomechanical preparation, in mesiodistal and buccolingual directions. A radiographic contrast medium was used for root canal filling, which allowed more adequate visualization on the radiographic films. For biomechanical preparation, the teeth were divided into three numerically equivalent groups according to the rotary system employed. Group I was instrumented with the system Protaper Universal, by utilization of shaping instruments in brushing motion and apical preparation finalized with an instrument F3. Group II was instrumented with the system Race, by utilization of Pre-Race instruments in brushing motion and apical preparation finalized with an instrument #30/0,06. Group III was instrumented with the system K3, by utilization of all instruments in pecking motion and apical preparation finalized with an instrument #30/0,06. The periapical radiographies containing the images before and after biomechanical preparation in both views were automatically developed and digitized on a platform scanner. The resulting images were stored in the software Adobe Photoshop 7.0 and imported to the software Image Tool 3.0. The percent increase in the root canal area was analyzed at the cervical, middle and apical thirds, for each study group, in both mesiodistal and buccolingual directions. Occasional changes in the original proportion between the buccolingual and mesiolingual areas, caused by biomechanical preparation, were also analyzed for each third. Data were analyzed by analysis of variance one-way and Tukey test at a significance level of 5% (p<0.05).
117

Análise morfológica e de resistência à flexão da interface ponta ativa/haste metálica em fresas carbide após o uso de esterilização /

Marcelo, Caroline Canhizares. January 2007 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Lígia Antunes Pereira Pinelli / Banca: Paulo Martins Ferreira / Resumo: Na prática odontológica os rigores de controle de infecção exigem do cirurgião-dentista procedimentos de esterilização e desinfecção sobre seus instrumentos para prevenir a infecção cruzada, porém, esses procedimentos podem levar à oxidação e, portanto, determinar o aparecimento de corrosão nos instrumentos rotatórios cortantes. Considerando as questões que têm sido levantadas sobre o efeito dos vários métodos de esterilização sobre a eficiência de corte e resistência dos instrumentos dentais, este trabalho teve como objetivo avaliar possíveis alterações morfológicas e também alterações na resistência de união ocorridas entre a ponta ativa/ haste metálica em fresas carbide causadas pelo uso e procedimentos de esterilização. Para tanto foram utilizadas 130 fresas carbide que foram divididas em grupos de acordo com o tratamento aplicado: controle, autoclave, estufa, microondas e glutaraldeído. Depois de completado o teste experimental proposto, todos os grupos foram submetidos ao teste de resistência à flexão. Foi realizada também análise morfológica (qualitativa) das fresas por fotomicrografias capturadas por meio de uma lupa estereoscópica LEICA com o software. Os dados foram devidamente anotados e submetidos à análise estatística com testes de Kruskal-Wallis e Dunn. Os resultados, tanto da avaliação morfológica quanto da resistência à flexão, mostraram que somente o grupo do glutaraldeído se comportou de maneira diferente do grupo controle, havendo diferença estatística significante entre esses dois grupos. E, os demais grupos foram estatisticamente semelhante ao grupo controle. Pode-se concluir que nenhum método físico de esterilização estudado (autoclave, estufa e microondas) influenciou negativamente as características morfológicas e a resistência de união da interface ponta ativa/haste metálica... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Such as in all professions related to health, in dentistry there are necessary procedures which limit or obstruct disease propagation through clinical practice. Among such procedures is the sterilization of rotary instruments to prevent the risk of cross-infection. Each day in clinical practice, physical and chemical methods of sterilization can corrode appearance. The presence of corrosion on rotary cutting instruments makes them unusable. Concerning questions that have been raised on effect of some sterilization methods on the cutting efficiency and dental instruments resistance, this paper aimed to evaluate the influence of cutting time, sterilization methods and the amount of sterilization cycles in morphologic alterations and fracture resistance between the cutting head/ steel shank of carbide burs. An in vitro study was carried out in which one hundred-thirty tungsten-carbide burs were divided into five groups in accordance with sterilization method: control; autoclave; dry heat; microwave and glutaraldehyde. Glass plates were cut for 2.5 minutes by each bur attached to a high-speed handpiece with an intermittent load of 0.68N. After cutting time, burs were cleaned, dried, and submitted to a sterilization method corresponding to each group. Each cutting time or sterilization cycles, the visual accompaniment of the burs and photographed under a stereomicroscope. All groups were submitted to the flexure strength test at the end of a stipulated time in the mechanical rehearsals machine, MTS. Results obtained were submitted to the Kruskal-Wallis test and Dunn, which showed that only the group of glutaraldeído had difference significant statistics of the control group and the another groups (autoclave, dry heat and microwave) had been statistical similar to the control group, in both the morphologic evaluation and the fracture resistance. It may be... (Complete abstract, click electronic access below) / Mestre
118

Esterilização de pontas diamantadas através da energia por microondas /

Farias, Renata Jansen de Mello. January 2003 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Alma Blásida Concepción Elizaur Benitez / Banca: Antonio Carlos Pizzolitto / Resumo: Tendo em vista a importância e necessidade de esterilização dos instrumentos cortantes rotatórios usados em odontologia, associada à indispensável agilidade nos atendimentos e, considerando ainda, a escassez de publicações atuais voltadas para este tema, julgou-se válida a preocupação em estudar a efetividade do método de esterilização através da energia por microondas em pontas diamantadas. Para tal, oitenta e uma pontas diamantadas foram contaminadas em uma suspensão bacteriana formada por bactérias pertencentes ao meio bucal (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divididas em três diferentes grupos e submetidas à irradiação por microondas em forno de microondas doméstico na potência máxima (800 W). Os grupos foram diferenciados entre si conforme o método de acondicionamento dos corpos-de-prova (2) e o procedimento para esterilização (3). No Procedimento de esterilização P1, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados em placas de Petri contendo 40 mL de água e submetidos à irradiação por microondas nos períodos de 0, 1, 2 e 3 minutos. No Procedimento de esterilização P2, os corpos-de-prova foram envolvidos em folha de poliéster, acondicionados em envelopes para esterilização e expostos à energia por microondas nos períodos de 0, 2, 4, 5 e 6 minutos, sem sofrerem previamente o procedimento de limpeza. E no Procedimento de esterilização P3, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados e submetidos à irradiação conforme o método anterior. A esterilização foi obtida tanto no Procedimento P1, no período de um minuto, quanto no Procedimento P3, no período de 6 minutos. Portanto, pudemos concluir...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Concerning the importance and the need for sterilization of the rotary cutting instruments used in dentistry, associated to the indispensable agility in the appointments and, considering also the scarceness of updated publications in regard to this theme, the preoccupation in studying the effectiveness of the sterilization method by the energy of microwaves in diamond burs was judged valid. To perform such study, eighty-one diamond burs were contaminated in a bacterial suspension formed by bacteria which belong to the oral environment (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divided in three different groups and submitted to irradiation by microwaves in a domestic microwave oven on maximum power (800 W). The groups were discriminated according to the method of packing of the specimens (2) and the procedure for sterilization (3). In the procedure for sterilization 1, the specimens were cleaned with steel sponge in water, packed in Petri dishes containing 40 mL of water and submitted to irradiation by microwaves in the periods of 0, 1, 2 and 3 minutes. In the procedure for sterilization 2, the test specimens were wrapped in a polyester sheet, packed in envelopes for sterilization and exposed to energy by microwaves in the periods of 0, 2, 4, 5 and 6 minutes, without going through the cleaning procedure previously. Finally, in the procedure for sterilization 3, the test specimens were cleaned with steel sponge in water, packed and submitted to irradiation according to the anterior method. The sterilization was obtained both in procedure 1, in the period of 1 minute, and in procedure 3, in the period of 6 minutes. Therefore, we could conclude that ...(Complete abstract, click electronic access below) / Mestre
119

Avaliação do efeito da afiação com diferentes técnicas sobre o ângulo de corte de curetas de Gracey /

Andrade Acevedo, Roberto Antonio. January 2003 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Silvana Regina Perez Orrico / Banca: Joni Augusto Cirelli / Banca: Enilson Antonio Sallum / Banca: Gibson Luiz Pilatti / Resumo: O presente trabalho teve por objetivo avaliar em fotomicrografias obtidas em microscópio eletrônico de varredura (MEV) o ângulo de corte de curetas de Gracey 5-6 em três níveis: afiação de fábrica, após ficarem sem corte e após serem reafiadas utilizando nove diferentes técnicas padronizadas de afiação: 1- face lateral da cureta contra a pedra Arkansas plana; 2- face coronal e posteriormente a lateral contra a pedra Arkansas plana; 3- pedra de Arkansas plana contra a face lateral da cureta; 4- cone de óxido de alumínio a baixa rotação contra a face coronal e em seguida a face lateral da cureta; 5- face lateral da cureta com pedra Arkansas 299; 6- face lateral da cureta com o aparelho padronizador Hu-Friedy; 7- face coronal da cureta com ponta de videa; 8- face coronal da cureta com ponta de videa e em seguida a face lateral com pedra de Arkansas plana; 9- afiação da face coronal com ponta de videa e em seguida pó abrasivo e roda de feltro rotatória na face lateral da cureta. Foram tomadas fotomicrografias (350X) do ângulo de corte e posteriormente avaliadas por um examinador calibrado através do índice do ângulo de corte. A analise estatística de Kruskal Wallis e comparações múltiplas mostraram que as técnicas 1 e 2 foram as melhores técnicas de afiação seguidas das técnicas 6, 5 e 8. As piores técnicas foram a 7, 9, 4, 0 e 3. A reafiação da face coronal das curetas produziu a formação de projeções metálicas não funcionais no ângulo de corte e finalmente não houve diferenças entre a afiação do extremo par e ímpar dos instrumentos em nenhuma das técnicas de afiação utilizadas. / Abstract: A micrographs obtained by a scanning electron microscope (SEM) were used to evaluated the gracey 5-6 cutting edges as the come from manufacture, after they had been dull and after they were resharpened by several standard techniques: 1- lateral surface over a flat Arkansas sharp stone; 2- coronal surface and the a lateral surface over a flat Arkansas sharp stone; 3- lateral surface by passing a flat Arkansas sharp stone; 4- rotatory aluminum oxide stone over a coronal surface and then over a lateral face; 5- lateral surface by passing an Arkansas 299 stone; 6- lateral surface on Hu-Friedy sharp divice; 7- coronal surface by a Whittler Neivert Device; 8- coronal face by a Whittler Neivert Device and the a lateral surface over a flat Arkansas sharp stone; 9- coronal surface with a Whittler Neivert Device and a rotating, impregnated, felt wheel on the lateral surface. The cutting edges was blindly evaluated on micrographs (X350) by one calibrated examiner (cutting angle index). A statistical analysis showed that techniques 1 and 2 were the best ones followed by a 6, 5 and 8 techniques. The worst techniques were a 7, 9, 4, 0 and 3. Resharpened on the coronal face of curettes generated a non functional wire edges on the cutting edge angle and there were not differences between the paired and unpaired extreme of the instruments resharpened. / Doutor
120

Desvio, capacidade de centralização e fadiga cíclica promovidos por instrumentos TF Adaptive e Navigator EVO, em diferentes cinemáticas

Duarte, Pedro Henrique Marks January 2017 (has links)
Introdução: A evolução dos instrumentos de NiTi pode ser dividida em gerações de acordo com algumas modificações tais como: tratamento térmico da liga, secção transversal e movimento utilizado para o preparo do canal, que pode ser movimento rotatório contínuo ou movimento oscilatório assimétrico. Essas mudanças tem como objetivo prover maior flexibilidade aos instrumentos, permitindo uma melhor modelagem do canal, com menor desvio e menor risco de perfurações. Outro aspecto relevante é a maior resistência à fadiga cíclica, das ligas com tratamento térmico, colaborando para uma maior resistência à fratura do instrumento. Objetivos: Este estudo comparou a fadiga cíclica, o transporte do canal , a capacidade de centralização e o volume do canal pós preparo, produzidos pelos sistemas TF Adaptive e Navigator EVO, quando utilizados em rotação contínua ou no movimento Adaptive. Métodos: Quarenta raízes mésio-vestibulares de molares superiores foram analisadas através de micro-CT antes e depois do preparo do canal radicular com os dois sistemas e dois movimentos (Adaptive e Rotação Contínua). As amostras foram divididas em quatro grupos: TFA – instrumentos TF Adaptive utilizados no movimento Adaptive; TFC –instrumentos TF Adaptive utilizados em rotação contínua; NA – instrumentos Navigator EVO utilizados no movimento Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Os canais radiculares foram preparados até instrumentos 35.04. O transporte apical, a capacidade de centralização e o volume de preparo foram analisados utilizando-se micro-CT em três níveis: 3, 6 e 9mm do ápice.O teste de fadiga cíclica foi realizado utilizando um equipamento apropriado, onde, dez instrumentos de cada marca foram utilizados em um contraângulo redutor 6:1 e um motor elétrico com controle de torque, com programas prédefinidos ‘‘custom mode'' e ‘‘TF Adaptive'' para ativar os instrumentos 25.06 e 35.04.Os resultados foram analisados com os testes Kruskal-Wallis eDunn para se verificar o transporte do canal, a capacidade de centralização e o volume do canal. O teste Student-T foi usado para avaliar a fadiga cíclica (P = 0,05). Conclusões: Ambos sistemas podem ser usados no movimento Adaptive ou em rotação contínua. Porém, a resistência à fratura dos instrumentos foi maior quando utilizados em rotação contínua. Pouco transporte de canal ocorreu, quando os canais mésio-vestibulares de molares superiores foram preparados até instrumentos 35.04. / Introduction: The evolution of NiTi instruments can be divided in generations, according to changes like in the NiTi alloy, heat treatment, cross-section format, and in the movement used for root preparation that goes form continuous rotation to asymmetric oscillation. These changes aim to provide greater flexibility to the instruments, allowing a better shaping, with less transportation and risk of perforation. Other aspect is the increased fracture resistance of the alloys with heat treatment, which is a big concern about NiTi instruments. Aim: This study compared the cyclic fatigue and the canal transportation promotedby TF Adaptive and Navigator EVO systems when used with two different motions. Methods: Forty mesiobuccal roots of maxillary molars were scanned using micro-CT imaging before and after root canal preparation with the two instrument systems two motions (adaptive and continuous rotation). Samples were divided into four groups: TFA – TF Adaptive instruments under adaptive motion; TFC - TF Adaptive instruments under continuous motion; NA - Navigator instruments under adaptive motion; and NC – Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation, centering ability and volume were analyzed using micro- CT at three levels: 3, 6 and 9 mm from the apex. The cyclic fatigue tests were performed using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs ‘‘custom mode'' and ‘‘TF Adaptive'' to activate25.06 and 35.04 instruments. Data were analyzed with Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability and canal volume. Student-T test was used to evaluate cyclic fatigue (P = .05). Conclusions: Both systems can be used under adaptive or continuous rotation. However; the lifespan of the instruments was higher when used under continuous rotation. Little canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04instruments.

Page generated in 0.1107 seconds