• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 30
  • 8
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 138
  • 138
  • 82
  • 33
  • 27
  • 26
  • 26
  • 25
  • 20
  • 19
  • 12
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Preparation of curved root canals with different nickel-titanium rotary systems three-dimensional comparison using micro-computed tomography /

Chiu, Mei-ling, Bonnie. January 2003 (has links)
Thesis (M.D.S.)--University of Hong Kong, 2003. / Includes bibliographical references (leaves 90-109). Also available in print.
82

Changes of mechanical properties of hypodermic needles as influenced by disinfection, sterilization and use a thesis submitted in partial fulfillment ... /

Cruz-Jasso, Horacio. January 1958 (has links)
Thesis (M.S.)--University of Michigan, 1958.
83

Comparison of muscle activity associated with varying structural differences in dental hygiene mirrors

Beck, Melanie Lea Simmer, Bray, Kimberly Krust. January 2004 (has links)
Thesis (M.S.)--School of Dentistry. University of Missouri--Kansas City, 2004. / "A thesis in dental hygiene education." Typescript. Advisor: Kimberly Krust Bray. Vita. Title from "catalog record" of the print edition Description based on contents viewed Feb. 22, 2006. Includes bibliographical references (leaves 68-70). Online version of the print edition.
84

Low-cycle fatigue of nickel-titanium rotary root-canal instruments /

Cheung, Shun-pan, Gary. January 2006 (has links)
Thesis (Ph. D.)--University of Hong Kong, 2007.
85

Efeito do método de esterilização e do tempo de uso sobre a eficiência de corte de fresas carbide

Pita, Ana Paula Gonçalves [UNESP] 18 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-18Bitstream added on 2014-06-13T19:58:16Z : No. of bitstreams: 1 pita_apg_me_arafo.pdf: 1343359 bytes, checksum: 231da834e04239550cc1df3e47d0e61b (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Considerando a importância do controle de infecção cruzada nos consultórios odontológicos, a vasta utilização de fresas de aço inoxidável/carbeto de tungstênio (carbide) e o receio dos cirurgiões dentistas em esterilizar esses instrumentos devido ao risco de danificá-los, o objetivo deste trabalho foi avaliar, comparativamente, o efeito de alguns métodos de esterilização, preconizados pela literatura e pelo Ministério da Saúde, sobre a eficiência de corte de fresas carbide. Os métodos de esterilização empregados foram: estufa, autoclave e forno de microondas; as marcas comerciais das fresas foram: Komet e S.S. White; e o tempo de aplicação desses instrumentos, em esmalte dental bovino, variou de 12 a 60 minutos. Para coleta dos dados, foram realizados testes gravimétricos e acompanhamento visual das fresas, após estas terem sido submetidas às diferentes condições experimentais. A análise dos resultados permitiu observar que ocorreu perda de eficiência de corte ao longo do tempo de utilização. Observou-se também que a partir de 60 minutos de aplicação em esmalte dental bovino, a eficiência de corte reduziu a 50% dos níveis iniciais. O efeito da esterilização foi diferente entre as marcas comerciais, sendo que cada uma se comportou de maneira diversa, em relação à quantidade de ciclos aplicados. Porém, a durabilidade total dos instrumentos não diferiu entre as marcas comerciais ou entre os métodos de esterilização aplicados. Considerando-se a importância e a responsabilidade do cirurgião dentista, quanto ao controle de infecção cruzada no ambiente do consultório odontológico, e comparando-se aos resultados relativos à durabilidade, evidenciados neste trabalho, pode-se afirmar que a utilização de métodos de esterilização, pode e deve ser adotada com segurança para esterilização de fresas carbide. / Dental burs inevitably become contaminated and the rotary cutting instruments as well as other instruments used in the treatment of patients must be sterilized after use by means of techniques that assure the asepsis, without damaging the instruments and its effectiveness, thus making possible its reuse. Concerning the importance of the control of infection crossed in the deontological clinicians further than the vast use of tungsten carbide burs and the distrust of the dentists in sterilized these instruments this study evaluated the effect of time usage (60 minutes) and sterilization (dry heat, vapor under pressure and energy for microwaves) over the cutting efficiency of carbide burs of two commercial brands. Gravimetrical tests were used for evaluation of the cutting efficiency and the visual acoompaniment of the burs was made along the test. It could be observed that the sterilization influenced in the cutting efficiency of the instruments, as well as the use time. From 60 minutes of application of the burs in the bovine dental enamel the cut efficiency were reduced at levels 50% minors when compared to the initial levels. These influences were different between instruments of the two commercial brands. Based on these results, it may be concluded that the effects of sterilization on cutting efficiency of carbide burs depends upon the composition of instruments and repeated cycles.
86

Avaliação da eficiência de corte de fresas Carbide em função dos métodos de esterilização físicos e químico. Análise gravimétrica /

Fais, Laiza Maria Grassi. January 2007 (has links)
Resumo: Este estudo avaliou o efeito de métodos de esterilização físicos e químico sobre a eficiência de corte de fresas carbide. Sessenta fresas da marca S.S. White foram utilizadas para o desgaste de vidro (30 mm X 30 mm X 10 mm) e divididas em cinco grupos experimentais em função do tratamento realizado: E1 - esterilização em autoclave, E2 - esterilização em estufa, E3 - esterilização em forno de microondas, E4 - esterilização em substância química e E0 - ausência de esterilização (controle). Com o auxílio de um aparelho padronizador de desgaste, as fresas foram utilizadas para o desgaste do vidro em um total de 30 minutos divididos em doze períodos de 2,5 minutos. Após cada 2,5 minutos de uso, as fresas foram limpas com escova de nylon sob água corrente e secas com jatos de ar e, em seguida, submetidas as seus respectivos tratamentos. A eficiência de corte das fresas foi determinada pela perda de massa do vidro, que teve sua massa aferida antes e após cada período de desgaste. A soma ( ? ) da quantidade de desgaste realizado por cada fresa após os 12 ciclos de uso foi calculada e utilizada para se determinar a eficiência de corte após 30 minutos de uso. Os valores da ? foram submetidos à análise estatística pelos testes de Kruskal-Wallis e de Dunn. Diferenças estatisticamente significantes entre os grupos experimentais foram verificadas (p<0,05). De acordo com os resultados, entre os métodos de esterilização avaliados, o uso o calor seco foi responsável pelo melhor desempenho das fresas, ao contrário da utilização de glutaraldeído, que foi considerado o pior método de esterilização. / Abstract: The aim of this study was to evaluate the influence of physical and chemical sterilization methods on the cutting effectiveness of carbide burs. Sixty S.S. White burs were used to cut glass plates (30 mm X 30 mm X 10 mm) and subjected to the following procedures: S1 - sterilization by autoclave; S2 - sterilization by dry heat; S3 - sterilization by microwave irradiation; S4 - sterilization by chemical substance and S0 - no sterilization (control group). The burs were used to cut glass plates in a cutting machine for twelve 2.5-minute periods. After each period, the burs were cleaned with a nylon brush under running water, dried with air spray (40 seconds), and then subjected to their procedures respectively. The cutting effectiveness was calculated by the weight loss of the glass which was weighed before and after each 2.5-minute period. The sum ( ? ) of the cutting amount performed by each bur after twelve cycles of use were calculated and used to determine the cutting effectiveness after 30 minutes of use. The ? values were statistically analyzed by Kruskal-Wallisþs and Dunnþs tests. Statistical differences among the experimental groups were observed (p <.05). According to the results, among the sterilization methods, the use of dry heat was responsible for the best carbide burs performance and, the use of glutaraldehyde was responsible for the worst burs performance. / Orientador: Gelson Luis Adabo / Coorientador: Lígia Antunes Pereira Pinelli / Banca: Regina Helena Barbosa Tavares da Silva / Banca: Daniela Atili Brandini / Mestre
87

Avaliação do efeito da afiação com diferentes técnicas sobre o ângulo de corte de curetas de Gracey

Andrade Acevedo, Roberto Antonio [UNESP] 18 August 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-08-18Bitstream added on 2014-06-13T19:04:27Z : No. of bitstreams: 1 andradeacevedo_ra_dr_arafo.pdf: 2469845 bytes, checksum: 6aef2f449ff6364a09cca9dd4566f240 (MD5) / O presente trabalho teve por objetivo avaliar em fotomicrografias obtidas em microscópio eletrônico de varredura (MEV) o ângulo de corte de curetas de Gracey 5-6 em três níveis: afiação de fábrica, após ficarem sem corte e após serem reafiadas utilizando nove diferentes técnicas padronizadas de afiação: 1- face lateral da cureta contra a pedra Arkansas plana; 2- face coronal e posteriormente a lateral contra a pedra Arkansas plana; 3- pedra de Arkansas plana contra a face lateral da cureta; 4- cone de óxido de alumínio a baixa rotação contra a face coronal e em seguida a face lateral da cureta; 5- face lateral da cureta com pedra Arkansas 299; 6- face lateral da cureta com o aparelho padronizador Hu-Friedy; 7- face coronal da cureta com ponta de videa; 8- face coronal da cureta com ponta de videa e em seguida a face lateral com pedra de Arkansas plana; 9- afiação da face coronal com ponta de videa e em seguida pó abrasivo e roda de feltro rotatória na face lateral da cureta. Foram tomadas fotomicrografias (350X) do ângulo de corte e posteriormente avaliadas por um examinador calibrado através do índice do ângulo de corte. A analise estatística de Kruskal Wallis e comparações múltiplas mostraram que as técnicas 1 e 2 foram as melhores técnicas de afiação seguidas das técnicas 6, 5 e 8. As piores técnicas foram a 7, 9, 4, 0 e 3. A reafiação da face coronal das curetas produziu a formação de projeções metálicas não funcionais no ângulo de corte e finalmente não houve diferenças entre a afiação do extremo par e ímpar dos instrumentos em nenhuma das técnicas de afiação utilizadas. / A micrographs obtained by a scanning electron microscope (SEM) were used to evaluated the gracey 5-6 cutting edges as the come from manufacture, after they had been dull and after they were resharpened by several standard techniques: 1- lateral surface over a flat Arkansas sharp stone; 2- coronal surface and the a lateral surface over a flat Arkansas sharp stone; 3- lateral surface by passing a flat Arkansas sharp stone; 4- rotatory aluminum oxide stone over a coronal surface and then over a lateral face; 5- lateral surface by passing an Arkansas 299 stone; 6- lateral surface on Hu-Friedy sharp divice; 7- coronal surface by a Whittler Neivert Device; 8- coronal face by a Whittler Neivert Device and the a lateral surface over a flat Arkansas sharp stone; 9- coronal surface with a Whittler Neivert Device and a rotating, impregnated, felt wheel on the lateral surface. The cutting edges was blindly evaluated on micrographs (X350) by one calibrated examiner (cutting angle index). A statistical analysis showed that techniques 1 and 2 were the best ones followed by a 6, 5 and 8 techniques. The worst techniques were a 7, 9, 4, 0 and 3. Resharpened on the coronal face of curettes generated a non functional wire edges on the cutting edge angle and there were not differences between the paired and unpaired extreme of the instruments resharpened.
88

Esterilização de fresas carbide em fornos de micro-ondas domésticos. Efeito da capacidade. da potência, do meio da imersão, da quantidade e posição da amostra sobre o tempo de esposição

Pita, Ana Paula Gonçalves [UNESP] 14 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-14Bitstream added on 2014-06-13T20:06:08Z : No. of bitstreams: 1 pita_apg_dr_arafo.pdf: 290018 bytes, checksum: ad154ba418a5be2bcb069526ffc6570a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O uso do forno de micro-ondas para a esterilização tem sido proposto em diferentes áreas. O tempo da exposição necessário para esterilizar água deionizada contaminada em diferentes posições dentro do forno foi avaliado e um método da esterilização de fresas carbide foi avaliado, considerando sua imersão ou não em 2 ml e 10 ml de água ou o óleo, a capacidade do forno (27 e 38 l), o nível de potência (400 e 600 W) e diferentes quantidades de instrumentos irradiados ao mesmo tempo (1, 5 e 10 fresas). Este trabalho foi feito em três etapas consecutivamente. Primeiramente, 10 ml da água deionizada foi contaminada por um dos três micro-organismos (Bacilus subtilis, Escherichia coli, Cândida albicans). A amostra contaminada foi situada em uma das 15 posições determinadas pela combinação das posições horizontais (anterior, posterior, direita, esquerda e central) e das posições verticais (sobre o prato giratório, 3 cm ou 5 cm acima do prato giratório) e foi submetida à irradiação por microondas (580 W) por 0,5, 1, 2, 5, 6, 7 ou 8 minutos. Nas etapas subseqüentes, as fresas estéreis foram contaminadas individualmente pelos mesmos micro-organismos. Após a contamindação, foram individualmente submetidas à irradiação (580 W) por 1, 2, 3, 4, 8, 9, 16, 17 ou 20 min em um frasco vazio ou contendo 2 ou 10 ml de água ou de óleo mineral. Na última etapa, os instrumentos contaminados foram irradiados individualmente ou nos grupos (5 ou 10 fresas), a aproximadamente 400 ou 600 W, em um dos dois fornos (27 ou 38 l) durante: 0,5; 1; 2; 3; 4; 5; 6; 8; 9.5; 10; 11; 13 ou 14,5 minutos. Após a irradiação foram adicionados 10 ml de meio fluido no frasco contendo os espécimes irradiados, que foram incubados a 37°C durante 48 h (B. 11 subtilis e E. coli) ou a 28ºC durante 72 h (C. albicans) para avaliação do efeito da esterilização pela turvação do caldo... / The use of microwave oven for sterilization has been proposed in different fields. The exposition time required to sterilize contaminated deionized water in different positions was evaluated and a microwave sterilization method of dental carbide burs was tested considering their immersion or not in 2 ml or 10 ml of water or oil, the oven capacities (27 l and 38 l), the level power (400 and 600 W) and different amount of instruments irradiated at the same time (1, 5 and 10 burs). This work was done in three stages consecutively. First, 10 ml of deionized water were inoculated with three microorganisms (Bacilus subtilis, Escherichia coli, Candida albicans). The contaminated sample was located at one of the 15 positions determined by the combination of horizontal positions (anterior, posterior, right, left, centre) and vertical positions (on the glass plate, 3 cm over the glass plate level, 5 cm over the glass plate level) and microwaved (580 W) for 0.3, 1, 2, 5, 6, 7 or 8 minutes. In the subsequent stages, sterile burs were individually inoculated with the same microorganisms. The contaminated burs were microwaved at 580 W for 1, 2, 3, 4, 8, 9, 16, 17 or 20 min in the dry state or immersed in 2 or 10 ml of water or mineral oil. In last stage, the contaminated instruments were microwaved individually or in groups (5 or 10 burs), at approximately 400 or 600 W, into the two ovens for: 0,5; 1; 2; 3; 4; 5; 6; 8; 9,5;10; 11; 13 or 14,5 minutes. After irradiation sterile broth was added into the flask containing irradiated specimens and incubated at 37°C for 48h (B. subtilis and E. coli) or at 28ºC for 72h (C. albicans), the sterilization effect was verified by the turbidity test. This study suggests that the position of the sample must be considered in domestic microwaves ovens sterilization methods and the central position should be avoided. The presence of a liquid material in contact... (Complete abstract click electronic access below)
89

Análise radiográfica da modelagem de canais radiculares ovalados realizada com sistemas rotatórios de níquel-titânio /

Croti, Hugo Ricardo. January 2008 (has links)
Orientador: Marcelo Gonçalves / Banca: Mário Tanomaru Filho / Banca: Carlos Alberto Herrero de Morais / Resumo: O objetivo deste estudo foi analisar radiograficamente a modelagem de canais radiculares ovalados realizada com três sistemas rotatórios de níqueltitânio. Foram utilizados 60 incisivos inferiores inseridos em blocos acrílicos, que acoplados a um sistema de plataforma radiográfica, permitiu a obtenção de imagens antes e após o preparo biomecânico, em sentido mésio-distal e vestíbulo-lingual. Um meio de contraste radiológico foi utilizado para preenchimento dos canais radiculares, proporcionando visualização mais adequada destes nas imagens radiográficas. Para o preparo biomecânico, os dentes foram divididos em três grupos (n=20), numericamente equivalentes, de acordo com o sistema rotatório utilizado. O grupo I foi instrumentado com o sistema Protaper Universal, tendo os instrumentos modeladores acionados em brushing motion e como último instrumento empregado para o preparo apical o F3. O grupo II foi instrumentado com o sistema Race, tendo os instrumentos Pré-Race acionados em brushing motion e como último instrumento empregado no preparo apical o #30/0,06. O grupo III foi instrumentado com o sistema K3, tendo todos os instrumentos acionados em pecking motion e como último instrumento utilizado no preparo apical o #30/0,06. As radiografias periapicais, contendo as imagens antes e após o preparo biomecânico, em ambos os sentidos, foram processados automaticamente e digitalizados em um scanner de plataforma. As imagens resultantes foram arquivadas no programa Adobe Photoshop 7.0 e importadas para o software Image tool 3.0. Avaliou-se o aumento percentual de área dos canais radiculares nos terços cervical, médio e apical, resultante em cada grupo experimental, nos sentidos mésio-distal e vestíbulo-lingual. / Abstract: The aim of this study was radiographically analyze the shaping of oval root canals obtained by utilization of three nickel-titanium rotary systems. It was conducted on 60 mandibular incisors embedded in acrylic blocks and connected to a radiographic platform system for achievement of images, before and after biomechanical preparation, in mesiodistal and buccolingual directions. A radiographic contrast medium was used for root canal filling, which allowed more adequate visualization on the radiographic films. For biomechanical preparation, the teeth were divided into three numerically equivalent groups according to the rotary system employed. Group I was instrumented with the system Protaper Universal, by utilization of shaping instruments in brushing motion and apical preparation finalized with an instrument F3. Group II was instrumented with the system Race, by utilization of Pre-Race instruments in brushing motion and apical preparation finalized with an instrument #30/0,06. Group III was instrumented with the system K3, by utilization of all instruments in pecking motion and apical preparation finalized with an instrument #30/0,06. The periapical radiographies containing the images before and after biomechanical preparation in both views were automatically developed and digitized on a platform scanner. The resulting images were stored in the software Adobe Photoshop 7.0 and imported to the software Image Tool 3.0. The percent increase in the root canal area was analyzed at the cervical, middle and apical thirds, for each study group, in both mesiodistal and buccolingual directions. Occasional changes in the original proportion between the buccolingual and mesiolingual areas, caused by biomechanical preparation, were also analyzed for each third. Data were analyzed by analysis of variance one-way and Tukey test at a significance level of 5% (p<0.05). / Mestre
90

Effects of High Speed Dental Drill Noise on Heart Rate in Normal Hearing Adult Males

Bunn, Thomas T. 01 January 1975 (has links) (PDF)
No description available.

Page generated in 0.4524 seconds