• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 6
  • 1
  • Tagged with
  • 32
  • 32
  • 22
  • 18
  • 14
  • 12
  • 11
  • 9
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effects of finishing and polishing of amalgams at specific time intervals a thesis submitted in partial fulfillment ... in pedodontics ... /

Busquets Lloréns, David Jaime. Osorno Escareño, Ma. del Carmen Gpe. Turner, Deborah Rede. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
2

Effects of finishing and polishing of amalgams at specific time intervals a thesis submitted in partial fulfillment ... in pedodontics ... /

Busquets Lloréns, David Jaime. Osorno Escareño, Ma. del Carmen Gpe. Turner, Deborah Rede. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
3

The effects of early and delayed finishing and polishing of amalgam restorations on gingival health thesis submitted in partial fulfillment ... restorative dentistry ... /

Zajia, Raul A. January 1984 (has links)
Thesis (M.S.)--University of Michigan, 1984.
4

A survey of the current practices of finishing and polishing of dental amalgam restorations a thesis submitted in partial fulfillment ... pedodontics ... /

Rogers, Angela M. January 1983 (has links)
Thesis (M.S.)--University of Michigan, 1983.
5

A survey of the current practices of finishing and polishing of dental amalgam restorations a thesis submitted in partial fulfillment ... pedodontics ... /

Rogers, Angela M. January 1983 (has links)
Thesis (M.S.)--University of Michigan, 1983.
6

The effects of early and delayed finishing and polishing of amalgam restorations on gingival health thesis submitted in partial fulfillment ... restorative dentistry ... /

Zajia, Raul A. January 1984 (has links)
Thesis (M.S.)--University of Michigan, 1984.
7

Análise rugosimétrica de duas cerâmicas odontológicas submetidas a diferentes tratamentos de superfície

Ticianeli, Márcio Giampá [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1 ticianeli_mg_me_arafo.pdf: 1350387 bytes, checksum: ea0f36454c6c9f5c29da9a1476668be1 (MD5) / Este estudo avaliou a eficiência de diferentes técnicas de acabamento e polimento sobre duas cerâmicas odontológicas (Duceram Plus e Duceram LFC), em relação à rugosidade média superficial (Ra). Foram preparados quarenta discos com 8 mm de diâmetro e 4 mm de espessura para cada uma das cerâmicas utilizadas, seguindo-se as recomendações do fabricante. Previamente ao glazeamento, todos os corpos-de-prova foram regularizados com o auxílio de lixas d'água de diferentes granulações (240,360 e 600, nesta ordem), recebendo, em seguida, uma camada de glaze. Os 40 corpos-de-prova de cada cerâmica foram divididos em 8 grupos com 5 representantes em cada um, recebendo diferentes tratamentos de superfície: T1- glaze; T2- desgaste com ponta diamantada fina e ultrafina; T3- T2 + sistema de acabamento e polimento dental Sof-Lex (3 M); T4- T3 + pasta diamantada; T5- T2 + kit de polimento Super-Snap (Shofu); T6- T5 + pasta diamantada; T7- T2 mais borrachas abrasivas Viking (KG Sorensen); T8- T7 + pasta diamantada. Foram realizadas cinco mensurações de rugosidade média (Ra, em æm) em cada corpo-de-prova, utilizando-se um rugosímetro ajustado com cut-off de 0,25 mm, extensão de tracejamento de 1,25 mm e velocidade de medição de 0,10 mm/s. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, com nível de significância de 5%. Os melhores tratamentos para ambas as cerâmicas avaliadas foram T3, T4, T5 e T6, apresentando semelhança estatística entre si; O glazeamento (T1) foi similar estatisticamente aos tratamentos T3, T4, T5 e T6 para a cerâmica Duceram LFC, em relação ao fator Ra; O tratamento T1 apresentou-se com diferença estatisticamente significante e mais rugoso que o tratamento T3, T4 e T6 para a cerâmica Duceram Plus, em relação ao fator Ra; As duas cerâmicas odontológicas avaliadas apresentaram... / This study assessed the efficacy of different current porcelain finishing and polishing procedures on two different dental ceramic (Duceram Plus and Duceram LFC) quantitatively with a profilometer. Forty disks (8 mm in diameter and 4 mm thick) were prepared for each dental ceramic according to the manufacturer's directions. Prior to glazing, all specimens' surfaces were abraded using a 240, 360 and 600-grit wet sandpaper. Then, all samples were glazed. The forty samples of each dental ceramic were divided into 8 groups of five specimens each, according to the surface treatment: T1- glaze; T2- abraded with fine and ultra fine diamond burs (KG Sorensen); T3- T2 following Sof-Lex (3M) polishing system; T4- T3 following diamond paste; T5- T2 following Super-Snap polishing kit (Shofu); T6- T5 following diamond paste; T7- Viking rubber wheels (KG Sorensen); T8- T7 following diamond paste. Five roughness measurements (Ra, æm) were performed on each disc using a profilometer with cut-off value of 0.25 mm and a tracing length of 1.25 mm and a speed of 0.1 mm per second. These values were tested using a two-way analysis of variance and Tukey test at 5% significance level. The result showed (to Ra factor) that T3, T4, T5 and T6 were the best surface treatment for both dental ceramic materials and were statistically equals; the glazed treatment (T1) was similar statistically to the polishing treatment T3, T4, T5 and T6 for Duceram LFC ceramic; the glazed treatment (T1) was different statistically and rougher than the polishing treatment T3, T4 e T6 for Duceram Plus ceramic; the two different dental ceramic had similar behavior when received the same surface treatment; and the diamond-abraded group (T2) had the rougher surface in both dental ceramic studied.
8

Influência do acabamento e polimento na estabilidade de cor e na rugosidade superficial de uma resina composta submetida a diferentes soluções fluoretadas

Oliveira, Ana Luísa Botta Martins de [UNESP] 30 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-30Bitstream added on 2014-06-13T20:36:16Z : No. of bitstreams: 1 oliveira_albm_me_arafo.pdf: 438115 bytes, checksum: dead0bfc4e29a4fcc0bc6644a0ce506c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito do acabamento e polimento na estabilidade de cor e na rugosidade superficial da resina composta Filtek Supreme XT em função de diferentes soluções fluoretadas. Para isso foram confeccionados corpos-de-prova (n= 140) por meio de uma matriz de aço inoxidável hemiseccionada com quatro orifícios circulares de 10 mm de diâmetro e 2 mm de espessura. A resina composta foi inserida na matriz num único incremento e fotoativada pelo aparelho de luz halógena Curing Light XL 3000 (3M/ESPE) por 40 segundos. Metade da amostra foi submetida a procedimentos de acabamento e polimento com discos de lixa Super-Snap® em ordem decrescente de granulação. Os grupos experimentais foram divididos de acordo com a presença ou ausência de acabamento e polimento e diferentes meios de imersão (saliva artificial, solução de fluoreto de sódio a 0,05%- manipulado, Fluordent Reach, Oral B, Fluorgard). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor no espectrofotômetro de colorimetria (Color guide 45/0, PCB 6807 BYK-Gardner GmbH Gerestsried, Alemanha) pelo sistema CIELab e à avaliação da rugosidade superficial (Ra) pelo rugosímetro portátil (Mitutoyo surftest SJ-401, Mitutoyo Corporation, Japão). A partir deste período, foram imersos nas diferentes soluções por 1 minuto ao dia durante 60 dias. Nos intervalos entre as imersões foram mantidos em saliva artificial a 37 _ 1 0C. As leituras da alteração de cor foram realizadas após 24 e 48 horas, 7, 14, 21, 30 e 60 dias do início da imersão e a da rugosidade superficial após 60 dias. Atendidos os pressupostos de normalidade e homocedasticidade, realizou-se Análise de Variância a dois fatores e teste de Tukey para comparações múltiplas, ambos com nível de significância de 5%. Para comparação das médias de rugosidade... / The aim of this study was to evaluate the effect of finishing and polishing procedures on the color stability and roughness of the Filtek Supreme XT resin composite surface submitted to different fluoride solutions. Samples were made (n= 140) in a hemi sectioned stainless steel mold with four 10-mm diameter and 2mm thick circular orifices. The composite resin was inserted in a single increment and light-cured with a halogen light curing unit (Curing Light XL 3000, 3M/ESPE) for 40 seconds. Half of each sample was submitted to finishing and polishing procedures with Super-Snap® grit disks in a decreasing order of granulation. Experimental groups were divided according to the presence or absence of finishing and polishing procedure and also to the different immersion media they were submitted to (artificial saliva, a manipulated 0, 05% sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were kept in artificial saliva for 24 hours and submitted to color analysis in a colorimetric spectrophotometer (Color guide 45/0, PCB 6807 BYK-Gardner GmbH Gerestsried, Germany) by the CIELab system and to superficial roughness (Ra) evaluation by a portable rugosimeter (Mitutoyo surftest SJ-401, Mitutoyo Corporation, Japan). From this period, specimens were immersed in the different solutions for 1 minute per day, during 60 days. In periods between immersions, they were kept in artificial saliva at 37 _ 1 0C. Color alteration evaluations were performed after 24 and 48 hours, 7, 14, 21, 30 e 60 days and superficial roughness after 60 days from the beginning of immersions. After normality and homoscedasticity presumption had been confirmed, the two-way Analysis of Variance and Tukey`s test for multiple comparisons were realized, both with a 5% significance level. For comparison of roughness means in baseline and in the 60 days... (Complete abstract click electronic access below)
9

Influência do acabamento e polimento na estabilidade de cor e na rugosidade superficial de uma resina composta submetida a diferentes soluções fluoretadas /

Oliveira, Ana Luísa Botta Martins de. January 2008 (has links)
Orientador: Patrícia Petromilli Nordi Sasso Garcia / Banca: Maria Cristina Borsatto / Banca: Welingtom Dinelli / Resumo: O objetivo deste estudo foi avaliar o efeito do acabamento e polimento na estabilidade de cor e na rugosidade superficial da resina composta Filtek Supreme XT em função de diferentes soluções fluoretadas. Para isso foram confeccionados corpos-de-prova (n= 140) por meio de uma matriz de aço inoxidável hemiseccionada com quatro orifícios circulares de 10 mm de diâmetro e 2 mm de espessura. A resina composta foi inserida na matriz num único incremento e fotoativada pelo aparelho de luz halógena Curing Light XL 3000 (3M/ESPE) por 40 segundos. Metade da amostra foi submetida a procedimentos de acabamento e polimento com discos de lixa Super-Snap® em ordem decrescente de granulação. Os grupos experimentais foram divididos de acordo com a presença ou ausência de acabamento e polimento e diferentes meios de imersão (saliva artificial, solução de fluoreto de sódio a 0,05%- manipulado, Fluordent Reach, Oral B, Fluorgard). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor no espectrofotômetro de colorimetria (Color guide 45/0, PCB 6807 BYK-Gardner GmbH Gerestsried, Alemanha) pelo sistema CIELab e à avaliação da rugosidade superficial (Ra) pelo rugosímetro portátil (Mitutoyo surftest SJ-401, Mitutoyo Corporation, Japão). A partir deste período, foram imersos nas diferentes soluções por 1 minuto ao dia durante 60 dias. Nos intervalos entre as imersões foram mantidos em saliva artificial a 37 _ 1 0C. As leituras da alteração de cor foram realizadas após 24 e 48 horas, 7, 14, 21, 30 e 60 dias do início da imersão e a da rugosidade superficial após 60 dias. Atendidos os pressupostos de normalidade e homocedasticidade, realizou-se Análise de Variância a dois fatores e teste de Tukey para comparações múltiplas, ambos com nível de significância de 5%. Para comparação das médias de rugosidade... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of finishing and polishing procedures on the color stability and roughness of the Filtek Supreme XT resin composite surface submitted to different fluoride solutions. Samples were made (n= 140) in a hemi sectioned stainless steel mold with four 10-mm diameter and 2mm thick circular orifices. The composite resin was inserted in a single increment and light-cured with a halogen light curing unit (Curing Light XL 3000, 3M/ESPE) for 40 seconds. Half of each sample was submitted to finishing and polishing procedures with Super-Snap® grit disks in a decreasing order of granulation. Experimental groups were divided according to the presence or absence of finishing and polishing procedure and also to the different immersion media they were submitted to (artificial saliva, a manipulated 0, 05% sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were kept in artificial saliva for 24 hours and submitted to color analysis in a colorimetric spectrophotometer (Color guide 45/0, PCB 6807 BYK-Gardner GmbH Gerestsried, Germany) by the CIELab system and to superficial roughness (Ra) evaluation by a portable rugosimeter (Mitutoyo surftest SJ-401, Mitutoyo Corporation, Japan). From this period, specimens were immersed in the different solutions for 1 minute per day, during 60 days. In periods between immersions, they were kept in artificial saliva at 37 _ 1 0C. Color alteration evaluations were performed after 24 and 48 hours, 7, 14, 21, 30 e 60 days and superficial roughness after 60 days from the beginning of immersions. After normality and homoscedasticity presumption had been confirmed, the two-way Analysis of Variance and Tukey's test for multiple comparisons were realized, both with a 5% significance level. For comparison of roughness means in baseline and in the 60 days... (Complete abstract click electronic access below) / Mestre
10

Influência do padrão de carga micro e nanométricas na rugosidade superficial de dentes humanos clareados e submetidos a diferentes tratamentos superficiais /

Araújo, Ariani Tainara Silva de. January 2018 (has links)
Orientador: André Afif Elossais / Resumo: A constante procura por procedimentos estéticos têm levado muitos pacientes e dentistas a realizarem o clareamento dental, por se tratar de um procedimento mini-mamente invasivo e conservador. Porém o gel clareador pode resultar em alterações estruturais do esmalte e afetar negativamente esta superfície. O objetivo deste estu-do in vitro foi avaliar a rugosidade e morfologia superficial do esmalte após o proto-colo de clareamento e os diferentes tratamentos superficiais de polimento. Para is-to, quarenta e oito (48) pré-molares humanos foram selecionados e clareados com o gel Opalescence Boost PF 40% (Ultradent) de acordo com a recomendação do fa-bricante. Após os protocolos de clareamento, os espécimes foram divididos em 8 grupos (n=6) e submetidos a polimento com: G1- Enamelize™ + Lummina E - Alu-mina, G2- Diamond Polish Paste™ + Lummina E - Diamond, G3- Lummina E - Di-amond, G4- discos abrasivos Sof-Lex Pop On® ultrafino, G5- Enamelize®, G6- Lummina E - Alumina, G7- Diamond Polish Paste® e G8- disco de feltro Diamond Flex®. Os espécimes foram submetidos as análises de perfilometria e microscopia de força atômica (AFM), para avaliar a rugosidade e morfologia superficial do esmal-te respectivamente. Ambas análises foram realizadas em dente hígido (baseline), clareado e polido. Para a avaliação da rugosidade superficial do esmalte dental hu-mano foi empregado o procedimento estatístico ANOVA de medidas repetidas com correção de Greenhouse-Geisser, seguido de comparações múlti... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Many patients have searched cosmetic procedures such as tooth bleaching once it is a minimally invasive and conservative treatment. However bleaching gel can cause enamel structural changes and negatively affect its surface. The aim of this in vitro study was to evaluate the enamel roughness and surface morphology after bleaching protocol and different surface polishing treatments. Forty-eight human premolars were bleached using 40% Opalescence Boost PF (Ultradent) according to the manufacturer's recommendations. Afterwards, the specimens were divided into 8 groups (n = 6) and polished using: G1- Enamelize™ + Lummina E - Alumina, G2- Diamond Polishing Paste™ + Lummina E - Diamond, G3- Lummina E - Diamond, G4- Sof-Lex Pop On® ultra-fine abrasive discs, G5- Enamelize®, G6- Lummina E - Alumina, G7- Diamond Polishing Paste® and G8- Diamond Flex® felt disc. The specimens were submitted to profilometry and atomic force microscopy (AFM) analy-sis to evaluate the enamel roughness and surface morphology. Both analyzes were performed on a sound (baseline), bleached and polished tooth. Surface roughness data were submitted to ANOVA and Greenhouse-Geisser correction, followed by multiple comparisons with Bonferroni correction, at 5% significance level. 40% Opalescence Boost PF bleaching gel significantly increased the enamel surface roughness (p <0.05). G1, G2, G3, G5, G6, showed statistically significant differences (p <0.05). G4, G7 and G8 did not show statistical difference (p> 0.05),... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0642 seconds