• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 6
  • 1
  • Tagged with
  • 32
  • 32
  • 22
  • 18
  • 14
  • 12
  • 11
  • 9
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação do brilho, rugosidade e integridade da superfície de cerâmicas odontológicas após o polimento, abrasão por escovação e repolimento das superfícies / Evaluation of surface gloss, roughness and integrity of dental ceramics after polishing, mechanical toothbrushing and repolishing

Ursi, Wagner José Silva 02 March 2011 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:22:38Z (GMT). No. of bitstreams: 1 Ursi_WagnerJoseSilva_D.pdf: 1229988 bytes, checksum: 2fcbeb63eb27770fcbe7f8c7c3ecdd07 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência de sistemas de polimento, da escovação mecânica e do repolimento sobre o brilho, rugosidade e morfologia da superfície de materiais cerâmicos. Três cerâmicas foram avaliadas: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) e Cercon CS (Degudent). Trinta amostras cilíndricas padronizadas de cada material foram confeccionadas e aleatoriamente divididas em 3 grupos (n=10) sendo que cada grupo foi submetido a um dos três procedimentos de polimento (taça de borracha; disco de feltro+pasta diamantada; taça de borracha + disco de feltro + pasta diamantada). Após o polimento, o brilho da superfície polida foi mensurado com medidor de brilho (ZGM 1120 Glossmeter - Zehntner) e a rugosidade avaliada através de rugosímetro (Surfcorder SE1700 - Kosaka Lab.). As amostras foram submetidas a 30.000 ciclos mecânicos de escovação, utilizando solução de dentifrício e água deionizada. Após a escovação, as mensurações de brilho e rugosidade foram repetidas. Em seguida, as amostras foram submetidas novamente aos procedimentos de polimento, e o brilho e a rugosidade avaliados novamente. Inicialmente foi realizada análise exploratória dos dados pelo aplicativo GUIDED DATA ANALYSIS do SAS (SAS, 2008). A seguir, os dados foram analisados, segundo o conceito de medidas repetidas no tempo, empregando o procedimento PROC MIXED e teste de Tukey-Kramer. Adicionalmente, amostras polidas, escovadas e repolidas foram examinadas em microscopia eletrônica de varredura (5600LV - Jeol) para avaliação qualitativa da integridade da superfície. Com base nos resultados encontrados, pode-se concluir que a superfície dos materiais cerâmicos foi resistente aos efeitos da escovação mecânica dentro das variáveis utilizadas, e que, o uso da pasta diamantada e disco de feltro, embora tenha se mostrado eficiente na diminuição da rugosidade de superfície (Ra) para a maioria das cerâmicas avaliadas, não foi capaz de alterar os valores originais de brilho superficial. / Abstract: The purpose of this in vitro study was to evaluate the influence of polishing systems, mechanical toothbrushing and repolishing on surface gloss, roughness and morphology of dental ceramics. Three ceramic systems were evaluated: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) and Cercon CS (Degudent). Thirty standardized cylindrical specimens of each material were fabricated and ramdomly divided in three groups (n=10), each group being submitted to one of the three polishing protocols (rubber cup; felt disc + diamond polishing paste; rubber cup + felt disc + diamond polishing paste). After polishing, surface optical gloss was determined using a gloss meter (ZGM 1120 Glossmeter - Zehntner) and surface roughness was measured with a surface profilometer ( Surfcorder SE 1700 -Kosaka Lab.). All specimens were submitted to 30,000 strokes at 2 Hz, with a dentifrice-water slurry. After mechanical toothbrushing, gloss and roughness measurements were evaluated again. Specimens were then repolished and submitted to gloss and roughness evaluations once more. Data were submitted to PROC MIXED and Tukey-Kramer tests. Aditionaly, randomly assigned specimens were evaluated for qualitative surface integrity under scanning electron microscopy (5600 LV-Jeol). Based on the results and the limitations of this in vitro study, it could be concluded that the surface of the ceramic materials tested was resistant to simulated toothbrushing challenge, and, the use of felt disc and diamond polishing paste, showed to be efficient in reducing surface roughness (Ra) for the majority of the tested ceramics, although unable to alter original surface gloss values. / Doutorado / Materiais Dentarios
22

Rugosidade e potencial anticariogênico de diferentes materiais restauradores adesivos com ou sem flúor / Roughness and anticariogenic potential of differents adhesive restorative materials with or without fluoride

Oliveira Júnior, Carlos da Cunha, 1979- 03 March 2011 (has links)
Orientadores: Luís Roberto Marcondes Martins, Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T02:16:19Z (GMT). No. of bitstreams: 1 OliveiraJunior_CarlosdaCunha_M.pdf: 1147567 bytes, checksum: ddfbf68f2d9875bfd54560350ef18e6e (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar o efeito do acúmulo de placa na rugosidade e o da liberação de flúor de materiais restauradores na desmineralização do esmalte ao redor das restaurações. As hipóteses testadas foram que materiais liberadores de flúor promovem menor extensão da desmineralização da estrutura dental adjacente e os materiais com monômeros resinosos possuem menor rugosidade de superfície. Para este estudo in vitro, 40 blocos de esmalte dentais bovinos foram divididos aleatoriamente em 4 grupos, cada qual com 10 fragmentos dentais restaurados com diferentes materiais: cimento de ionômero de vidro modificado por resina (Vitremer), nanoparticulado (Ketac N100), cimento ionomérico convencional (Ketac Molar), compósito resinoso (Filtek Z250). Os blocos dentais foram submetidos a um modelo de desmineralização bacteriano. Em seguida, os blocos restaurados foram levados ao rugosímetro para avaliação da rugosidade a qual foi comparada com discos dos materiais testados, confeccionados como padrões de rugosidade, então, o teste de microdureza foi realizado para se obter a dureza Knoop da estrutura dentaria adjacente ao material restaurador com indentações nos pontos 50, 100 e 150 ?m de distância, nas profundidades de 10 a 120 ?m, considerando as medidas a partir de 100 ?m com valores similares ao do esmalte hígido e os valores foram convertidos em volume mineral pela fórmula de Featherstone (1983). Em seguida, foi feita a análise do conteúdo mineral da interface esmalte/restauração, após a ação dos ácidos bacterianos pela microanálise de raio-x. Os resultados mostraram que todos os grupos submetidos ao desafio cariogênico tiveram aumento significativo de rugosidade superficial. O grupo dos compósitos resinosos sofreu menor aumento significativo de rugosidade, seguida dos cimentos resinosos modificados por resina, o nanoparticulado e o convencional. Os valores de volume mineral no grupo da Z250 foi significativamente menor que os grupos com cimentos ionoméricos. A microanálise revelou conteúdo de cálcio significativamente maior nos grupos restaurados com cimentos ionoméricos. Isto permitiu concluir que os materiais com conteúdo resinoso possuem melhor polimento superficial e que o esmalte adjacente aos restauradores que liberam flúor sofreu menor desmineralização, além de apresentar maior conteúdo de cálcio / Abstract: The aim of this study was to evaluate the effect of plaque accumulation on roughness and fluoride release from dental materials on enamel demineralization around restorations. The hypothesis was that fluoride-releasing materials have lower extent of demineralization of adjacent tooth structure. For this in vitro study, 40 bovine dental enamel blocks were randomly divided into four groups, each with 10 dental fragments restored with different materials: resin-modified glass ionomer cement (Vitremer), nanoionomer (Ketac N100), conventional glass ionomer cement (Ketac Molar), resin composite (Filtek Z250). The dental blocks were subjected to a bacterial demineralization model. Then the restored blocks were taken to rugosimeter for evaluation of the roughness which was compared with discs of the tested materials, prepared as roughness patterns, then the microhardness test was performed to obtain the hardness of tooth structure adjacent to the restorative material with indentations at points 50, 100 and 150 ?m apart, at depths from 10 to 120 ?m, considering the measures from 100 ?m with values similar to sound enamel and the values were converted to mineral volume by the formula Featherstone (1983). Next step was to analyze the mineral content of enamel interface / restore, after the action of bacterial acid by x-ray microanalysis. The results showed that all groups submitted to cariogenic challenge significantly increased surface roughness. The group of composite resins has increased significantly lower roughness, followed by resin-modified resin cements, the nanoionomer and conventional. The values of mineral volume in the group of Z250 was significantly lower than groups with ionomer cements. The microanalysis showed calcium content significantly higher in groups restored with glass ionomer cements. It was concluded that materials with resin content have better polishing surface and the enamel adjacent to fluoride releasing restorative suffered less demineralization, as well as the higher calcium content / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
23

Analise quantitativa e qualitativa do acumulo de placa bacteriana in situ em resinas compostas com superficies lisas e rugosas / Quantitative and qualitative analysis of in situ bacterial plaque retention in composites with smooth and rough surfaces

Leite Junior, Fernão Helio de Campos 28 February 2005 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T01:07:01Z (GMT). No. of bitstreams: 1 LeiteJunior_FernaoHeliodeCampos_D.pdf: 1914892 bytes, checksum: 9e016f7a5b89737fc1d4f4114e5ab871 (MD5) Previous issue date: 2005 / Resumo: O objetivo desta pesquisa foi avaliar a influência da rugosidade superficial das resinas compostas de diferentes partículas de carga, sobre o acúmulo de placa bacteriana in situ, através da quantificação por meio de espectrofotometria e qualificação para o grupo mutans streptococci pela técnica da reação em cadeia da polimerase (¿polymerase chain reaction¿ - PCR). Assim, foram confeccionados corpos de prova cilíndricos com os compósitos: Durafill VS, Tetric Ceram e Filtek P60, apresentando duas superfícies produzidas pela fotoativação do compósito em contato com a tira matriz de poliéster - superfície lisa e pelos Discos Sof-Lex de granulação grossa - superfície rugosa. Da interação resina composta e textura superficial foram constituídos 6 grupos experimentais: Durafill VS/Superfície Lisa, Durafill VS/Superfície Rugosa, Tetric Ceram/Superfície Lisa, Tetric Ceram/Superfície Rugosa, Filtek P60/Superfície Lisa e Filtek P60/Superfície Rugosa. A rugosidade superficial dos corpos de prova foi avaliada pela leitura em rugosímetro (Ra). Para a avaliação do acúmulo de placa bacteriana in situ, foram selecionados dez voluntários, para os quais foram confeccionados dispositivos palatinos em acrílico, onde foram fixados seis corpos de prova correspondentes a cada grupo experimental. Os voluntários utilizaram o dispositivo com os corpos de prova por três dias na semana. No quarto dia das primeiras seis semanas, a placa formada sobre cada corpo de prova foi extraída em NaOH 1,0M e quantificada em espectrofotômetro. Os corpos de prova com superfície rugosa apresentaram maior acúmulo de placa bacteriana do que aqueles com superfície lisa, independente da resina composta utilizada. Entre os corpos de prova lisos, apesar de haver diferença estatística significativa entre a menor rugosidade superficial da resina composta de micropartículas (Durafill VS) e a maior rugosidade das outras duas resinas compostas (Filtek P60 e Tetric Ceram), não foi observada diferença no acúmulo de placa entre os materiais testados. Na sétima semana, o DNA da placa bacteriana acumulada sobre os corpos de prova foi extraído e comparado através de PCR utilizando primers universais para bactérias do grupo mutans streptococci, que amplificam genes de RNA ribossômico 16S e digestão do produto da amplificação com as enzimas de restrição HaeIII, CfoI e RsaI. Constatou-se a presença de bactérias do grupo mutans streptococci nos corpos de prova confeccionados com as três resinas compostas testadas. Verificou-se semelhança nos perfis gerados pela análise de PCR-RFLP das amostras dos voluntários, indicando que as resinas compostas, Tetric Ceram, Durafill VS ou Filtek P60 e o tipo de superfície, lisa ou rugosa, não afetaram significativamente a composição da placa bacteriana acumulada nos corpos de prova para o grupo mutans streptococci / Abstract: The aim of this study was to evaluate the effect of surface roughness of different filled composites on in situ bacterial plaque retention, quantified by spectrophotometry and qualified for mutans streptococci group by polymerase chain reaction (PCR). Specimens were prepared with the composites Durafill VS, Tetric Ceram and Filtek P60, with smooth and rough surfaces, produced by phtotoactivation through Mylar strip or Sof-Lex discs, respectively. The interaction composite x texture surface generated six experimental groups: Durafill VS/smooth surface, Durafill VS/rough surface, Tetric Ceram/smooth surface, Tetric Ceram/rough surface, Filtek P60/smooth surface and Filtek P60/rough surface. Surface roughness of samples was evaluated by profilometer reading (Ra). For in situ experiment, ten subjects were chosen which wore acrylic palatal appliances containing samples of the six experimental groups. All subjects wore the appliances for three days a week. In the fourth day of the first six weeks, the amount of dental plaque formed on the samples were extracted in 1.0M NaOH and analyzed by spectrophotometry. Rough surface samples showed significantly greater amount of bacterial plaque than smooth surface samples, for the three composites tested. For the smooth samples, in spite of the significant difference between the lower roughness of Durafill VS composite and the higher roughness of both Filtek P60 and Tetric Ceram composites, no difference was observed in the amount of bacterial plaque among the tested materials. In the seventh week, DNA of the bacterial plaque formed on the samples was extracted and compared by PCR using universal primers for mutans streptococci group, which amplify ribossomal RNA 16S genes, and digestion of PCR products with the restriction enzymes HaeIII, CfoI e RsaI. Bacteria of mutans streptococci group were found in all composites samples. The profiles generated by the PCR-RFLP analysis of the volunteers' samples were similar, indicating that the composites Tetric Ceram, Durafill VS or Filtek P60 and the smooth or rough surfaces did not affect significantly the composition of the bacterial plate formed on the samples for mutans streptococci grou / Doutorado / Dentística / Doutor em Clínica Odontológica
24

Alterações nas caracteristicas da superficie de compositos restauradores sumetidas a diferentes tecnicas de acabamento e polimento / Changes in surface characteristics of restorative composites subjected to different techniques for finishing and polishing

Schmitt, Vera Lucia 15 August 2018 (has links)
Orientador: Regina M. Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T22:41:21Z (GMT). No. of bitstreams: 1 Schmitt_VeraLucia_D.pdf: 11168795 bytes, checksum: b69f581b456234d9e5ae85cea9754de1 (MD5) Previous issue date: 2010 / Resumo: Inúmeras alterações foram feitas na fabricação das resinas compostas fotoativáveis, especialmente na tentativa de obter melhor estabilidade de cor, adequada resistência ao desgaste e lisura de superfície clinicamente aceitável. Neste contexto, fabricantes têm, promovido alterações no tamanho das partículas de carga e incorporado a maior quantidade de componentes inorgânicos no interior da matriz resinosa. Além da composição do material, os procedimentos de acabamento e polimento podem também influenciar na qualidade superficial da resina composta, relacionando-se diretamente com rugosidade. Superfícies rugosas predispõem a restauração a maior retenção de biofilme bacteriano, facilitando o desenvolvimento de lesões cariosas, manchamentos além de interferir no seu brilho e estética finais. Neste contexto, esta tese propôs a avaliar qualitativamente a topografia de superfície de resinas compostas microhíbridas e nanoparticuladas, em função de diferentes combinações entre técnicas de polimento e resinas compostas. Com objetivo didático, esta tese foi dividida em 3 partes, como descrito a seguir. Parte 1: avaliar a influência que diferentes técnicas de acabamento e polimento exercem sobre a rugosidade da superfície de uma resina composta nanoparticulada. Parte 2: comparar a estabilidade de cor e a característica de superfície promovida por técnicas de acabamento e polimento que empregam um ou múltiplos passos sobre resinas microhíbridas e nanoparticuladas, correlacionando com a geometria e composição das partículas inorgânicas das resinas compostas. Parte 3: aferir de forma quantitativa e qualitativa, por meio da rugosidade superficial e microscopia eletrônica de varredura, respectivamente, o efeito de técnicas de acabamento e polimento de resinas compostas nanoparticuladas, nanohíbridas e microhíbridas. Há uma relação direta entre os sistemas de acabamento e polimento e a qualidade superficial das resinas. Sistemas de múltiplos passos tendem a ser melhores em comparação aos de passo único, qualquer que seja o tipo de resina composta empregada. Já a forma e o tamanho das partículas de carga exercem influência sobre a lisura e manchamento, sendo que resinas composta nanoparticuladas apresentam melhor lisura e estabilidade de cor em relação às micro-híbridas. A lisura e o manchamento são materiais e polimento dependentes. / Abstract: Several changes were made in the light-cured composites resins manufacture, especially trying to obtain better color stability, adequate wear resistance and clinically acceptable surface smoothness. About this, manufacturers have predominantly reduced the diameter of charged particles, promoting changes in its geometry and also incorporating a bigger amount of inorganic components within the resin matrix. Besides the material composition, the procedures of finishing and polishing may influence in the composite resin surface quality, relating directly with roughness. Rough surfaces predispose to the restoration a greater retention of bacterial biofilms, facilitating the development of secondary caries, discoloration and staining as well as interfering in their brilliance and aesthetic. In this context, this thesis intends to qualitatively evaluate the surface topography of microhybrid and nanoparticle composite resins, in different combinations for polishing techniques of resin composites. With instructional purposes, this thesis was divided into 3 parts, as described below. Part 1: assessing the influence that different finishing and polishing techniques have on the surface roughness of a nanoparticle composite resin. Part 2: compare the color stability and the surface feature promoted by finishing and polishing techniques of single or multiple steps in nanoparticulate and microhybrid resins, correlating with composite resins geometry and inorganic particles composition. Part 3: assess in a quantitatively and qualitatively way, through surface roughness and electron microscopy scanning, respectively, the effect of different finishing and polishing techniques of hybrid and microhybrid composite resins. There is a direct relationship between finishing and polishing systems and resins surface quality. Systems of multiple steps tend to be better when compared to single step systems, regardless to the type of the resin used. The shape and diameter of charged particles influence on the smoothness and staining, nanoparticulate resins present better surface smoothness and color stability in relation to micro-hybrid resins. Smoothness and staining are materials and polishing dependents. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
25

Avaliação in vitro da rugosidade superficial de resinas compostas, comparando diferentes sistemas de acabamento e polimento e após a profilaxia com jato de bicarbonato / In vitro evaluation of surface roughness of different composite resins, comparing different finishing and polishing systems and after prophylaxis with bicarbonate jet

Carol Brandt Alves 04 October 2012 (has links)
A presente pesquisa in vitro teve como objetivo avaliar a ocorrência de alterações superficiais em três resinas compostas disponíveis comercialmente quando submetidas a tratamentos de polimento e jato de bicarbonato. As alterações foram quantificadas através de análises rugosimétricas e qualificadas através de microscopia eletrônica de varredura. Foram testadas três resinas compostas:nanoparticulada Z350 (3M ESPE, Saint Paul- MN, EUA), microhíbrida Z250 (3M ESPE, Saint Paul- MN, EUA) emicroparticulada Durafill (Heraeus Kulzer, Germany). Para cada resina foram confeccionados quinze corpos de prova com o auxílio de uma matriz aço inox com 7mm de diâmetro e 3 mm de espessura em dois incrementos e fotoativadas seguindo as orientações do fabricante. Os corpos de prova foram mantidos em água destilada a 37°C por 24 horas. Em seguida foram sub divididos em três grupos de acordo com protocolos de acabamento e polimento sendo avaliados o polimento com pontas Enhance® + PoGo (Dentsply, Konstanz, Germany), pontas Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) e discos Sof Lex Pop On (3M ESPE, Saint Paul- MN, EUA). Todos os espécimes foram submetidos à ciclagem térmica de 5 a 55 °C com tempo de imersão 1 minuto por 1000 ciclos. Após a ciclagem os espécimes foram submetidos a jato de bicarbonato (equipamento Ortusonic Ortus, Campo Mourão, PR, Brasil) por 30 segundos. A rugosidade de superfície foi avaliada com o auxílio de uma aparelho rugosímetro ( Mitutoyo SJ- 201P Mitutoyo Tokyo, Japão) em três momentos, sendo a primeira leitura, baseline, realizada após 24hs da confecção dos corpos de prova. A segunda, após o polimento dos corpos de prova e a terceira, após a profilaxia com jato de bicarbonato. A rugosidade foi medida em cinco locais diferentes em cada espécime. Os resultados foram analisados levando em consideração a rugosidade média (Ra), em micrômetros (m). Posteriormente foram realizadas análises ao microscópio eletrônico de varredura. De acordo com a metodologia empregada, conclui-se que a resina que apresentou maior rugosidade de superfície foi a microparticulada (Durafill), as menores rugosidades foram observadas nas resinas compostas nanoparticulada (Z350) e microhibrida (Z250). Os discos Sof Lex Pop On e as pontas Enhance e PoGo produziram superfícies mais lisas do que o sistema de polimento com as pontas Astropol, tais resultados podem ser confirmados com a análise em Microscopia Eletrônica de Varredura (M.E.V). / This in vitro study aimed to evaluate the occurrence of surface changes in three commercially available resin composites when subjected to polishing treatments and bicarbonate jet. The changes were quantified through roughness analysis and qualified by scanning electron microscopy. We tested three composites: nanoparticulated Z350 (3M ESPE, St. Paul, MN, USA), microhybrid Z250 (3M ESPE, St. Paul, MN, USA) e microparticuladed Durafill (Heraeus Kulzer, Germany). For each resin were prepared fifteen test specimens with the aid of a stainless steel matrix with 7mm diameter and 3 mm thick and photoactivated in two increments following the manufacturer\'s instructions. The specimens were kept in water at 37 ° C for 24 hours. Then were divided into three groups according to protocols being evaluated finishing and polishing polishing tips with Enhance ® + PoGo (Dentsply, Konstanz, Germany), tips Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) and Sof Lex Pop On disks (3M ESPE, St. Paul, MN, USA). All specimens were subjected to thermal cycling 5-55 ° C with a soak time of 1 minute per 1000 cycles. After cycling the specimens underwent bicarbonate jet (Ortusonic Ortus equipment, Campo Mourao, Parana, Brazil) for 30 seconds. The surface roughness was evaluated with the aid of a machine rugosimeter (Mitutoyo Mitutoyo SJ-201P Tokyo, Japan) in three stages, with the first reading, baseline, performed 24 hours after the making of the specimens. The second, after polishing the samples and the third, after prophylaxis with bicarbonate jet. The roughness was measured at five different locations on each specimen. The results were analyzed taking into account the average roughness (Ra) in micrometers (mm). Later analyzes were performed by scanning electron microscope. According to the methodology, it is concluded that the resin with the highest surface roughness was microparticulated (Durafill), the lowest roughness was observed in nanoparticled composites (Z350) and microhybrid (Z250). The Sof Lex Pop On disks and tips Enhance and PoGo produced smoother surfaces than polishing system with tips Astropol, these results can be confirmed with the analysis in Scanning Electron Microscopy (SEM).
26

Estudo in vitro da formação do biofilme de Candida albicans em resina acrílica termopolimerizável revestida por nanopartículas de dióxido de silício (revestimento cerâmico) / In vitro study of C. albicans biofilm growth on heat-polymerized acrylic resin coated with silicon dioxide nanoparticles (ceramic coating)

Oliveira, Denise Gusmão de 29 May 2013 (has links)
A proposta deste trabalho foi analisar um produto experimental (VIPI LTDA, Pirassununga, SP), que através da tecnologia sol-gel, modifica a superfície de resinas acrílicas para base de próteses e forma uma camada de nanopartículas de sílica (NPS) visando diminuir o acúmulo e facilitar a remoção de microrganismos. Dessa forma, inicialmente, confirmou-se a deposição de NPS e formação do revestimento cerâmico em polimetilmetacrilato (PMMA) através de espectroscopia no infravermelho por Transformada de Fourier (FTIR); e posteriormente, quantificou-se o biofilme de Candida albicans nesta superfície através da contagem de unidades formadoras de colônia (UFC/mL) e microscopia confocal (MC). Um total de 51 espécimes (10x10x3mm) de PMMA foi confeccionado e distribuído aos experimentos designados. Para a análise da composição dos espécimes em FTIR, foram avaliados 3 grupos (n=1): CN- espécime que não recebeu tratamento algum; CP- espécime que recebeu a aplicação do primer do produto; CL- espécime que passou tanto pela aplicação do primer como pelo processo sol-gel. Na etapa seguinte, foram utilizados 48 espécimes divididos em 3 grupos (n=16), de acordo com o tipo de polimento: PM3- mecanicamente polido com 3&#x3BC;m de rugosidade média; PM03- mecanicamente polido com 0,3&#x3BC;m de rugosidade; PL- polido quimicamente pelo líquido conforme instruções do fabricante. Anteriormente aos experimentos, os espécimes foram esterilizados por óxido de etileno e, então, imersos em saliva artificial por 2hs para a formação da película adquirida. Em seguida, foram secos e inoculados com 2mL de suspensão de C. albicans (1.107 cel/mL) para adesão das células fúngicas durante 90min. Após esta fase, as amostras foram lavadas em solução salina e imersas em meio estéril (RPMI) para crescimento do biofilme em estufa sob agitação (12hs a 37oC). Metade do número das amostras de cada grupo (n=8) foi destinada a contagem de UFC/mL e a outra metade dos espécimes (n=8), foi designada ao método de MC, que com o auxílio de um software (BioImageL v.2), permitiu a determinação do biovolume total (&#x3BC;m3), biovolume de células viáveis (&#x3BC;m3), biovolume de células não-viáveis (&#x3BC;m3) e área de cobertura do campo pelo biofilme (%). Os dados obtidos pelo FTIR foram analisados através da estatística descritiva. Os resultados obtidos pelos experimentos de quantificação após teste de normalidade Kolmogorov-Smirnov foram analisados através do teste paramétrico ANOVA, seguido do teste de Tukey para comparações entre grupos (p<0,05). Através do FTIR, observou-se a deposição satisfatória da camada de NPS, permitindo assim, o desempenho dos experimentos de quantificação. Os resultados do UFC/ml e MC demonstraram semelhança na quantificação do biofilme entre os grupos PL e PM3, e diferença quando comparados ao grupo de superfícies mais lisas, PM03. Dessa forma, observou-se que o polimento líquido experimental não foi efetivo para a diminuição da colonização de biofilme deC. albicans em superfícies de PMMA. Entretanto, maiores investigações sobre as propriedades de superfície deste revestimento devem ser realizadas, já que o processo sol-gel permite uma facilidade na modificação dessas características, podendo levar ao desenvolvimento de um material de revestimento ideal. / This study investigates an experimental coating (VIPI LTDA, Pirassununga, SP) by sol-gel process that modifies acrylic resin denture base with silicon dioxide nanoparticles (SNP) to decrease C. albicans biofilm growth. Therefore, it was first investigated the presence of sol-gel ceramic coating on polymethylmethacrylate (PMMA) by Fourier Transform Infrared Spectroscopy (FTIR). Then C. albicans biofilms were quantified by colony forming units (CFU/mL) and confocal scanning laser microscopy (CSLM). Fifty-one PMMA specimens were manufactured (10x10x3mm) and assigned to the experiments. To evaluate specimens composition, it was analyzed three groups (n=1): CN- the specimen did not receive any surface treatment; CP- it was applied the coating primer on the specimen surface CL- the specimen was treated with the whole sol-gel process. In the following stage, 48 samples were divided into 3 groups (n=16) according to the polish type: PM3- 3&#x3BC;m of roughness mechanical polish; PM03- 0,3&#x3BC;m of roughness mechanical polish; PL- liquid polish. Samples of experimental group were coated according to manufacturers instructions and all the samples were sterilized with ethylene oxide. After that, they were dipped in artificial saliva for 2hs to acquire the salivary pellicle, and then, dried and inoculated with 2 mL suspension of C.albicans (1.107 cel/mL) for 90 min. Then, specimens were washed and immersed in sterile RPMI solution (37oC for 12h). Half of the samples of each group (n=8) was assigned to each quantification test (UFC/mL and CSLM). By CSLM and software (BioImageL v.2) analysis was possible to obtain the total biovolume (&#x3BC;m3), viable biovolume (&#x3BC;m3), non-viable biovolume (&#x3BC;m3), and covered area (%) by C. albicans biofilm. The data obtained by FTIR were analyzed by descriptive statistic. Whereas the records acquired by the quantification experiments were first analyzed by Kolmogorov-Smirnov normality test and then by one way ANOVA followed by Tukeys test to assess difference between groups (p<0,05). FTIR results showed an adequate SNP deposition, allowing the quantification tests to be performed. UFC/mL and CLSM records showed similarity between PL and PM3 groups and difference when comparing these groups to smoother surfaces group (PM03). Therefore, in this study, the experimental coating was not effective to reduce colonization by C. albicans biofilm on PMMA surfaces. Nevertheless, further investigations are required since sol-gel ceramic coating process eases the features modification of the material, possibly leading to an ideal coating development.
27

Estudo in vitro da formação do biofilme de Candida albicans em resina acrílica termopolimerizável revestida por nanopartículas de dióxido de silício (revestimento cerâmico) / In vitro study of C. albicans biofilm growth on heat-polymerized acrylic resin coated with silicon dioxide nanoparticles (ceramic coating)

Denise Gusmão de Oliveira 29 May 2013 (has links)
A proposta deste trabalho foi analisar um produto experimental (VIPI LTDA, Pirassununga, SP), que através da tecnologia sol-gel, modifica a superfície de resinas acrílicas para base de próteses e forma uma camada de nanopartículas de sílica (NPS) visando diminuir o acúmulo e facilitar a remoção de microrganismos. Dessa forma, inicialmente, confirmou-se a deposição de NPS e formação do revestimento cerâmico em polimetilmetacrilato (PMMA) através de espectroscopia no infravermelho por Transformada de Fourier (FTIR); e posteriormente, quantificou-se o biofilme de Candida albicans nesta superfície através da contagem de unidades formadoras de colônia (UFC/mL) e microscopia confocal (MC). Um total de 51 espécimes (10x10x3mm) de PMMA foi confeccionado e distribuído aos experimentos designados. Para a análise da composição dos espécimes em FTIR, foram avaliados 3 grupos (n=1): CN- espécime que não recebeu tratamento algum; CP- espécime que recebeu a aplicação do primer do produto; CL- espécime que passou tanto pela aplicação do primer como pelo processo sol-gel. Na etapa seguinte, foram utilizados 48 espécimes divididos em 3 grupos (n=16), de acordo com o tipo de polimento: PM3- mecanicamente polido com 3&#x3BC;m de rugosidade média; PM03- mecanicamente polido com 0,3&#x3BC;m de rugosidade; PL- polido quimicamente pelo líquido conforme instruções do fabricante. Anteriormente aos experimentos, os espécimes foram esterilizados por óxido de etileno e, então, imersos em saliva artificial por 2hs para a formação da película adquirida. Em seguida, foram secos e inoculados com 2mL de suspensão de C. albicans (1.107 cel/mL) para adesão das células fúngicas durante 90min. Após esta fase, as amostras foram lavadas em solução salina e imersas em meio estéril (RPMI) para crescimento do biofilme em estufa sob agitação (12hs a 37oC). Metade do número das amostras de cada grupo (n=8) foi destinada a contagem de UFC/mL e a outra metade dos espécimes (n=8), foi designada ao método de MC, que com o auxílio de um software (BioImageL v.2), permitiu a determinação do biovolume total (&#x3BC;m3), biovolume de células viáveis (&#x3BC;m3), biovolume de células não-viáveis (&#x3BC;m3) e área de cobertura do campo pelo biofilme (%). Os dados obtidos pelo FTIR foram analisados através da estatística descritiva. Os resultados obtidos pelos experimentos de quantificação após teste de normalidade Kolmogorov-Smirnov foram analisados através do teste paramétrico ANOVA, seguido do teste de Tukey para comparações entre grupos (p<0,05). Através do FTIR, observou-se a deposição satisfatória da camada de NPS, permitindo assim, o desempenho dos experimentos de quantificação. Os resultados do UFC/ml e MC demonstraram semelhança na quantificação do biofilme entre os grupos PL e PM3, e diferença quando comparados ao grupo de superfícies mais lisas, PM03. Dessa forma, observou-se que o polimento líquido experimental não foi efetivo para a diminuição da colonização de biofilme deC. albicans em superfícies de PMMA. Entretanto, maiores investigações sobre as propriedades de superfície deste revestimento devem ser realizadas, já que o processo sol-gel permite uma facilidade na modificação dessas características, podendo levar ao desenvolvimento de um material de revestimento ideal. / This study investigates an experimental coating (VIPI LTDA, Pirassununga, SP) by sol-gel process that modifies acrylic resin denture base with silicon dioxide nanoparticles (SNP) to decrease C. albicans biofilm growth. Therefore, it was first investigated the presence of sol-gel ceramic coating on polymethylmethacrylate (PMMA) by Fourier Transform Infrared Spectroscopy (FTIR). Then C. albicans biofilms were quantified by colony forming units (CFU/mL) and confocal scanning laser microscopy (CSLM). Fifty-one PMMA specimens were manufactured (10x10x3mm) and assigned to the experiments. To evaluate specimens composition, it was analyzed three groups (n=1): CN- the specimen did not receive any surface treatment; CP- it was applied the coating primer on the specimen surface CL- the specimen was treated with the whole sol-gel process. In the following stage, 48 samples were divided into 3 groups (n=16) according to the polish type: PM3- 3&#x3BC;m of roughness mechanical polish; PM03- 0,3&#x3BC;m of roughness mechanical polish; PL- liquid polish. Samples of experimental group were coated according to manufacturers instructions and all the samples were sterilized with ethylene oxide. After that, they were dipped in artificial saliva for 2hs to acquire the salivary pellicle, and then, dried and inoculated with 2 mL suspension of C.albicans (1.107 cel/mL) for 90 min. Then, specimens were washed and immersed in sterile RPMI solution (37oC for 12h). Half of the samples of each group (n=8) was assigned to each quantification test (UFC/mL and CSLM). By CSLM and software (BioImageL v.2) analysis was possible to obtain the total biovolume (&#x3BC;m3), viable biovolume (&#x3BC;m3), non-viable biovolume (&#x3BC;m3), and covered area (%) by C. albicans biofilm. The data obtained by FTIR were analyzed by descriptive statistic. Whereas the records acquired by the quantification experiments were first analyzed by Kolmogorov-Smirnov normality test and then by one way ANOVA followed by Tukeys test to assess difference between groups (p<0,05). FTIR results showed an adequate SNP deposition, allowing the quantification tests to be performed. UFC/mL and CLSM records showed similarity between PL and PM3 groups and difference when comparing these groups to smoother surfaces group (PM03). Therefore, in this study, the experimental coating was not effective to reduce colonization by C. albicans biofilm on PMMA surfaces. Nevertheless, further investigations are required since sol-gel ceramic coating process eases the features modification of the material, possibly leading to an ideal coating development.
28

CAD/CAM monolithic materials : wear resistance and abrasiveness, and the effect of grinding and polishing on their roughness and fracture resistance. /

Ludovichetti, Francesco Saverio January 2019 (has links)
Orientador: Renata Garcia Fonseca / Resumo: Esta tese consiste em dois estudos, ambos investigando materiais monolíticos fresados por tecnologia CAD-CAM. Primeiro estudo. Objetivo. A resistência ao desgaste e abrasividade do Lava Ultimate, Vita Enamic, Vita Suprinity, IPS e.max CAD e Lava Plus, bem como algumas propriedades que podem estar relacionadas, foram analisadas. Métodos. Espécimes desses materiais tiveram sua rugosidade, dureza e coeficiente de atrito avaliados, respectivamente, em microscópio confocal, microdurômetro e tribômetro. O teste de desgaste conhecido como "2-body", no qual os materiais atuaram como abrasivos e, juntamente com o esmalte bovino, também como antagonistas, também foi realizado. A taxa de desgaste foi determinada com perfilômetro de superfície e as superfícies desgastadas foram observadas por microscopia eletrônica de varredura (MEV). Resultados. Vita Enamic e Lava Ultimate mostraram a maior rugosidade, enquanto IPS e.max CAD e Vita Suprinity, a menor. O resultado da dureza foi Lava Plus> (Vita Suprinity = IPS e.max CAD)> Vita Enamic> Lava Ultimate. O Lava Ultimate exibiu maior coeficiente de atrito do que o IPS e.max CAD e o Lava Plus. O Lava Plus e o IPS e.max CAD mostraram um potencial significativamente maior para desgastar o Lava Ultimate. Estes dois materiais, juntamente com o Vita Suprinity, foram os que mais desgastaram o esmalte e o Vita Enamic. Vita Suprinity e IPS e.max CAD promoveram o maior desgaste do Lava Plus, e o inverso também ocorreu. Vita Enamic e Lava Ultimate causar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This thesis consists of two studies, both investigating the computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic materials. First study. Aim. The wear resistance and abrasiveness of Lava Ultimate, Vita Enamic, Vita Suprinity, IPS e.max CAD, and Lava Plus, as well as some properties that might be related to, were analyzed. Methods. Specimens from these materials had their roughness, hardness, and coefficient of friction evaluated, respectively in confocal microscope, microdurometer, and tribometer. The 2-body wear test, wherein the materials acted as abraders and, together with bovine enamel, also as antagonists, was also carried out. The wear rate was determined with surface profilometer and the worn surfaces were observed by scanning electron microscopy (SEM). Results. Vita Enamic and Lava Ultimate showed the highest roughness, whereas IPS e.max CAD and Vita Suprinity, the lowest. The hardness result was Lava Plus > (Vita Suprinity=IPS e.max CAD) > Vita Enamic >Lava Ultimate. Lava Ultimate exhibited a higher coefficient of friction than IPS e.max CAD and Lava Plus. Lava Plus and IPS e.max CAD showed significantly higher potential to wear Lava Ultimate. These two materials, together with Vita Suprinity, provided the highest wear of enamel and Vita Enamic. Vita Suprinity and IPS e.max CAD exhibited the highest wear against Lava Plus, and the inverse also occurred. Vita Enamic and Lava Ultimate were among the materials that caused the lowest wear of ename... (Complete abstract click electronic access below) / Doutor
29

Influência de diferentes resinas compostas e técnicas de polimento sobre os tecidos periodontais próximos a lesões cervicais não cariosas avaliação clínica randomizada

Teixeira, Nancielli 23 February 2015 (has links)
Made available in DSpace on 2017-07-10T14:57:28Z (GMT). No. of bitstreams: 1 Nancielli Teixeira - Influencia de diferentes_ resinas e tecn.pdf: 1668593 bytes, checksum: 73d67bc8169b66441386241284104ea5 (MD5) Previous issue date: 2015-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the influence of different composite resins and technical polishing and finishing over periodontals tissues and gingival crevicular fluid in cervical lesions restorations noncarious (LCNC). Initially were evaluated 272 teeths of patients with complaints related to LCNC and, acordding to the inclusion and exclusion criteria were selected 60 teeths for elegibility. Each tooth received a restoration with a kind of composite resin (Resin Tetric N-Ceram® or Resin Z350 XT®) in both quadrants, varying the polishing technique ( Astropol® Polishing rubber or Sof-lex® Disks). Periodontal tissues analysis, the longitudinal evaluation of restaurations and the gengival crevicular fluid collect were taken prior to scalling and root planning and also at 30, 60, 120 and 180 days of restaurations making. After the data collection and tabulation , these were submited to the Friedman test, with a significance level of 5%. The results revealed that resins and polishing techniques applied in this study showed no estatistical differences at the end of follow-up in any of the analyzes. However all groups evaluated showed differences between the initial and final times (p <0.05). From the results obtained it was concluded that regardless of the restorative material or polishing technique, the restoration of LCNC cavities improved the periodontal health of patients / O objetivo desse trabalho foi avaliar a influência de diferentes resinas compostas e técnicas de acabamento e polimento sobre os tecidos periodontais e o fluído crevicular gengival em restaurações de lesões cervicais não cariosas. Foram avaliados inicialmente 272 dentes de pacientes com queixas relacionadas à LCNC e, a partir dos critérios de inclusão e exclusão definidos, foram selecionados para elegibilidade 60 dentes, divididos em 4 grupos com N:15 dentes. Cada dente recebeu restauração com um tipo de resina composta nanoparticulada (Resina Tetric N-Ceram® ou Resina Z350 XT®) nos dois hemiarcos, variando a técnica de polimento (Borrachas de polimento Astropol® ou Discos Sof-lex®). A análise periodontal dos tecidos, a avaliação longitudinal das restaurações e a coleta do fluido crevicular gengival foram realizadas antes da raspagem e alisamento corono-radicular, e também aos 30, 60, 120 e 180 dias após a confecção das restaurações. Após a obtenção e tabulação dos dados, esses foram submetidos ao teste de Friedman, com nível de significância de 5%. Os resultados revelaram que as resinas e as técnicas de polimento utilizadas neste estudo não apresentaram diferenças estatísticas ao final do período de acompanhamento em nenhuma das análises. Porém, todos os grupos avaliados apresentaram diferenças entre os tempos iniciais e finais (p<0,05). A partir dos resultados obtidos foi possível concluir que, independente do material restaurador ou da técnica de polimentos utilizada, a restauração das cavidades de LCNC proporcionou melhora da saúde periodontal dos pacientes
30

Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem / Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage

VENTURINI, Daniela 30 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:17Z (GMT). No. of bitstreams: 1 Dissertacao_Daniela_Venturini.pdf: 913438 bytes, checksum: e17fa4ddbe1c025e3411319cac841d1e (MD5) Previous issue date: 2006-06-30 / This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups / Este estudo avaliou os efeitos do polimento imediato e mediato na rugosidade média superficial (Ra), dureza Knoop (KHN) e microinfiltração de um compósito microparticulado (Filtek A110) e um híbrido (Filtek Z250), após um ano de armazenagem dos espécimes. Preparos padronizados de 3mm mesio-distais, 3mm inciso-cervicais e 2mm de profundidade foram realizados na face vestibular de 256 incisivos bovinos, metade destes foi restaurada com cada tipo de compósito. Imediatamente após a fotoativação realizado o acabamento com lixa d água de granulação 280. Os espécimes restaurados com cada compósito foram divididos em dois grupos. O primeiro grupo (IM) foi polido imediatamente após o acabamento, usando três sistemas diferentes (n=16): A- Sof-Lex (3M-ESPE), B- FlexiCups (Cosmedent), C- (técnica seqüencial)- a seqüência de FlexiCups, Jiffy Polishing Brush (Ultradent) e FlexiBuffs (Cosmedent). Os espécimes foram então armazenados em solução salina a 37ºC. O segundo grupo (ME) foi armazenado por duas semanas e então polido com os mesmos sistemas. Parte dos espécimes foi analisada numa primeira etapa do experimento e o restante ficou armazenado por um ano em água destilada a 37ºC. Cinco leituras por espécimes foram realizadas para Ra e KHN. Após imersão em fucsina básica realizou-se o teste de penetração de corante sendo após analisado sob aumento (40x) usando escores padrão. Os dados foram verificados através de Análise de Variância e teste SNK (Ra e KHN). Também foram utilizados os testes de Mann-Whitney ou Kruskal-Wallis (microinfiltração). Para comparação com os dados baseline foram utilizados os testes t de Student (Ra) e Mann-Withney (infiltração marginal). Todos os testes foram executados com significância de 5%. Após um ano de armazenagem os espécimes do compósito A110 apresentaram significativamente menor rugosidade e menor dureza. A técnica seqüencial promoveu a menor rugosidade e os discos Sof-Lex a menor dureza, essas diferenças foram estatisticamente significantes. Os escores de infiltração marginal foram semelhantes entre os grupos. Após um ano de armazenagem os espécimes apresentaram um aumento significativo na rugosidade. O polimento IM mostrou-se igual, ou melhor, que o ME tanto para a infiltração marginal como para a rugosidade superficial para a maioria dos grupos analisados, no entanto tal fato não foi observado quanto à dureza superficial, exceto quando foi utilizada a técnica seqüencial

Page generated in 0.0766 seconds