21 |
The comparison of a wax check bite system to mechanical axiography in setting the horizontal condylar path on a semi-adjustable articulatorAkkad, Salem. January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2007. / Title from document title page. Document formatted into pages; contains viii, 55 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 52-55).
|
22 |
Precisão das técnicas de moldagem e vazamento para próteses implantossuportadasDel'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1
delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
|
23 |
Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados /Muñoz Chávez, Alejandro. January 2007 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Sergio Sualdini Nogueira / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below) / Mestre
|
24 |
Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhadosMunhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1
munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
|
25 |
Precisão das técnicas de moldagem para próteses implantossuportadasDel'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1
delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
|
26 |
Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper archEliseu Antonio Bueno Junior 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
|
27 |
Avaliação bidimensional e tridimensional na adaptação marginal de retentor metálico fundido e coping; obtidos por um novo protocolo com moldagem única /Sichi, Luigi Giovanni Bernardo. January 2019 (has links)
Orientador: Rodrigo Máximo de Araújo / Coorientadora: Samia Carolina Mota Cavalcanti Sacorague / Banca: Paula Carolina Komori de Carvalho / Banca: Fernanda de Cássia Papaiz Gonçalves / Resumo: A otimização do tempo reabilitador é um benefício direto a saúde do paciente, pois previne o mesmo do contato com possíveis contaminações e ambientes que lhe causem estresse. Isso pode ser viabilizado pelo desenvolvimento de técnicas que diminuam etapas de execução de um determinado tratamento. Pensando nisso, esse trabalho tem por objetivo avaliar a desadaptação marginal de copings em liga de cobalto-cromo (Co-Cr) através da técnica da réplica de silicone (2D) e avaliação por varredura digital (3D), em 24 dentes humanos unirradiculares, com retentores intraradiculares (RIR) em Co-Cr, cimentados com cimento de fosfato de zinco. Divididos em dois grupos, ambos com término marginal em ombro 130º: grupo A obtidos pelo método convencional, com execução de RIR primeiro, para depois coping com retentor já cimentado e grupo B de moldagem única para obtenção de RIR e coping. Os resultados foram submetidos a uma análise do teste t e de variância ANOVA. A técnica da réplica de silicone, demonstrou as seguintes médias de valores marginais: 83,77±51,84μm (grupo A) e 77,09±31,65μm (grupo B) p=0,4477 E a varredura digital, os resultados positivos revelaram que as médias de todas as superfícies encontraram-se acima de 50 μm; e os negativos: revelaram que as médias encontraram-se abaixo de 100 μm. Este estudo concluiu que é possível obter RIR e coping através de moldagem única / Abstract: The optimization of the clinical appointment is a direct benefit to the health of the patient, because prevents it from the contact with possible contaminations and environments that cause stress. This can be possible by the development of techniques that may decrease the execution stages of a treatment. With this in mind, the aims of this study is to investigate the marginal adaptation of Cobalt-Chromium alloy (Co-Cr) copings through silicone replica technique (2D) and digital evaluation (3D) in 24 human single rooted teeth with post-and-core in Co-Cr, cemented with zinc phosphate. Divided in to two groups, both having shoulder 130 degrees as marginal type: group A by the conventional method, impression and cementation of Co-Cr post-and-core first and then impression for the coping and group B single impression for coping and post and core. The results were analyzed by test t and one-way ANOVA. The silicone replica technique showed the following mean marginal values: 83.77 ± 51.84 μm (group A) and 77.09 ± 31, 65 μm (group B) p= 0,4477. The digital protocol, in the positive results revealed that the averages of all surfaces were above 50 μm; and the negatives: revealed that the averages were below 100 μm. This study concluded that it is possible to obtain post-and-core and coping through a single impression technique / Mestre
|
28 |
Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for full-arch implant-supported prostheses: an in-vitro studyHajjar, Lea George 11 August 2022 (has links)
OBJECTIVES: The purpose of this in vitro study is to measure and compare the accuracy of the conventional impression, the intraoral scanner, and the photogrammetry techniques for full-arch implant-supported dental prostheses at the abutment level.
METHODS: An edentulous maxillary master model containing 6 implant abutment replicas (RP analog for screw-retained abutment straight from NobelReplace® Multi-unit Abutment Plus Replica) was fabricated. A reference STL of the master model was obtained using a desktop scanner (inEos X5, Dentsply Sirona) with high trueness and precision and served as the control STL. Three impression techniques were performed: the intraoral scanning (IOS) group (TRIOS 3 Battery Cart, 3Shape A/S), the photogrammetry (PTG) group (ICam 4D Generation 3, Imetric), and the conventional (CNV) group. Ten impressions from each group were tested. Scan bodies in each STL file acquired from the different impression techniques were converted to implant abutment replicas using a digital library. Three tests were completed to compare the different registration techniques. A 3D deviation test between the experimental group and the reference was done on an inspection software (IScan4D Dental Version 9.1.104; Imetric) using a “best fit” algorithm to obtain the root mean square values, and on another inspection software (IScan3D Dental Version 9.1.104; Imetric) using spatial similarity transformation. The second test was meant to assess the angular deviations of the implant abutment replicas using a reverse engineering software (Geomagic Control X 2020.1; 3D Systems). The final test for cross-arch distances was done on an inspection software (IScan3D Dental Version 9.1.104; Imetric) which allows to determine the 3-dimensional coordinates for each implant by using the origin point and compare the cross-arch distance deviations as well as deviations at the x-, y-, and z- coordination. Trueness and precision were the two parameters used to define the accuracy of a system. The term "trueness" was used to see how close the measurements from the experimental files of each group were to those of the reference file. The term "precision" was defined as to see how close the measurements of each experimental files were to each other within the same group. The 3D discrepancies were then calculated and the trueness and precision of the three impression techniques were assessed and compared statistically (α = 0.05).
RESULTS: The root mean square of 3D deviation values through the ICP “best-fit” method showed statistically significant differences between the PTG and CNV group (p < .0001), and the PTG and IOS group (p < .0001). The CNV and IOS group did not show statistically significant differences (p = 0.8626) through the “best-fit” method, but significant differences were observed via the “spatial similarity” method (p = 0.0041). Both methods however showed the best results in terms of trueness for the PTG group, followed by the CNV group and least the IOS group. In terms of precision, PTG showed the best results, followed by the IOS group and least the CNV group. The angular deviation test using the “best-fit” alignment method showed that the PTG and CNV had no statistically significant difference (p = 0.7955) and were equivalent. However, both showed a statistically significant difference to the IOS group (p < .0001), which had the highest angular deviation. Finally, in terms of cross-arch distances, the photogrammetry group showed optimal results followed by the IOS group and then the CNV group. In general, the shorter the inter-arch distance, the lower the deviation was. A larger deviation was observed on longer inter-arch distances. Considering the deviations on the 3 axes of each implant, the CNV technique had the highest deviation in the X-axis (longitudinal) and the IOS technique showed the highest deviation on the Y-axis (lateral) and Z-axis (vertical). The PTG technique experienced significantly less deviation on the X-axis, Y-axis, and the Z-axis.
CONCLUSION: Within the scope of this study, the photogrammetry technique reported the best accuracy in terms of trueness and precision of implant positions for complete-arch implant rehabilitation. Conventional impressions showed better accuracy results than intraoral scanning in the 3D deviations test and global angular deviation test, however the latter exhibited better results in terms of accuracy in terms of cross-arch distances test. / 2023-08-11T00:00:00Z
|
29 |
Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas /Del'Acqua, Marcelo Antonialli. January 2005 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Marcelo Ferrarezi de Andrade / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below) / Mestre
|
30 |
Influência de técnicas e materiais de moldagem, tempos e materiais de vazamento na exatidão tridimensional de modelos /Messias, Aion Mangino. January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo analisou a exatidão de modelos totais de gesso, obtidos a partir de diferentes técnicas e materiais de moldagem, tempos e materiais de vazamento, levando em consideração as mensurações de área, volume e angulação nos eixos X, Y e Z de pontos de referência específicos em modelo mestre (baseline), moldes e, por posteriormente, em modelos de gesso de cada condição experimental. Foi utilizado um modelo mestre com preparos nos dentes 14, 16, 21 e 25, com demarcações pontuais em suas superfícies oclusais, que funcionavam como pontos de referência. Realizaram-se três técnicas de moldagem: (T1) mistura simultânea, (T2) reembasamento - alívio com filme de PVC e (T3) moldagem digital (escâner intra-oral) - Cerec Conect Omnicam (Sirona). Para cada técnica de moldagem/tempo de vazamento foram obtidos 8 moldes totais, por único operador calibrado (ICC=0,99), com moldeira metálica de estoque e silicone de condensação (Speedex; Coltène/Whaledent Inc.) ou adição (Express XT; 3M ESPE). Os vazamentos foram realizados com gessos tipo IV convencional (GC Fuji Rock EP - GC America) e de expansão nula (Zero Stone - Dentona AG). Nos moldes com silicone de condensação o gesso foi vazado após 30 minutos, 3 ou 7 dias. Nos moldes em silicone de adição os modelos foram obtidos após 2 horas, 3, 7 ou 15 dias. Para a análise tridimensional, utilizou-se software para gerenciamento de imagens e análise das malhas tridimensionais (Rhinoceros - versão 5.3.2) obtidas com escâner óptico de bancada (R... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study analyzed the accuracy of total gypsum casts obtained from different casting techniques and materials, casting times and materials, taking into account the measurements of area, volume and angulation in the X, Y and Z axes of reference points specific master model (baseline), in the impression and, later, in the gypsum casts of each experimental condition. A master model was used with teeth 14, 16, 21 and 25, with punctual demarcations on its occlusal surfaces, which functioned as reference points. Three impression techniques were performed: (T1) simultaneous mixing, (T2) relining-relief with PVC film and (T3) chairside digital impression - Cerec Conect Omnicam (Sirona). For each impression technique / casting time, 8 total impression were obtained by single calibrated operator (ICC = 0.99), with metal stock tray and condensation silicone (Speedex; Coltène / Whaledent Inc.) or addition (Express XT 3M ESPE). The gypsum casts pouring process were performed with type IV conventional gypsum (GC Fuji Rock EP - GC America) and zero expansion one (Zero Stone - Dentona AG). For impressions with condensation silicone the cast was poured after 30 minutes, 3 or 7 days. For the addition silicone impressions, the gypsum casts were obtained after 2 hours, 3, 7 or 15 days. For the three-dimensional analysis, a software was used to manage threedimensional images (Rhinoceros - version 5.3.2) allowing the investigation of virtual images (three-dimensional meshes) made with an optical... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.095 seconds