• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 14
  • 13
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de fadiga em próteses odontológicas implanto-suportada sob carregamento multiaxiais. / Analysis of failure in implanto-supported odontological prostheses under multiaxial loading.

Losada, Henry Figueredo 13 November 2018 (has links)
Próteses odontológicas são estruturas que restituem a função mastigatória e substituem componentes dentários danificados. A maioria dos estudos em próteses odontológicas que envolve métodos analíticos clássicos de análise de estrutura são inviáveis e situações nas quais a experimentação é dificultosa. Estas próteses, sob condições reais de carregamentos cíclicos (mastigação), são repetidamente sujeitas à estados de tensões multiaxiais cíclicas. Neste sentido, a natureza cíclica do carregamento, a qual os componentes das próteses são submetidos, sugere que o modo de falha por fadiga possui maior relevância neste tipo de estrutura. O desenvolvimento da computação eo aumento das capacidades de processamentos tem permitido maior implementação dos métodos numéricos, como o Métodos de Elementos Finitos (MEF). Através deste método (MEF) se realiza a modelagem do comportamento mecânico ajustadas à realidade física dos fatores biomecânicos envolvidos. Em uma revisão bibliográfica, verificou-se que a maioria dos livros e artigos encontrados não apresentam informação detalhadas sobre a previsão da vida baseado em análises de fadiga multiaxial que utilizem o MEF para cálculo das próteses odontológicas. O objetivo deste trabalho foi propor um modelo numérico computacional utilizando o MEF para avaliar a vida à fadiga em próteses odontológicas submetidas a carregamentos multiaxiais. Para isso, foi empregada a manipulação de imagens adquiridas, ensaios experimentais normativos, Análise por Elemento Finitos (FEA) na previsão de vida à fadiga aplicada tanto em carregamento uniaxial ou multiaxial, a contabilização do dano por fadiga em carregamento multiaxial de amplitude variáveis, otimização e implementação de subrotina para as interfaces APDL -MATLAB. Os resultados mostraram que, através das técnicas de aquisição de dados de imagens (Micro-CT) e medições mecânicas combinadas com métodos numéricos consegue-se modelar uma estrutura complexa como uma prótese dental. / Dental prostheses are structures that restore the masticatory function and replace damaged dental components. Most studies on dental prostheses involve that classical analytical methods of structure analysis are infeasible and situations in which experimentation is difficult. These prostheses, under real conditions of cyclic loading (chewing), are repeatedly subjected to cyclic multiaxial stress states. In this sense, the cyclical nature of the loading, to which the components of the prosthesis are submitted, suggests that the fatigue failure mode has greater relevance in this type of structure. The development of computation and the increase of processing capacities have allowed greater implementation of numerical methods, such as Finite Element Methods (FEM). Through this method (FEM) it is performed the modeling of the mechanical behavior which is adjusted to the physical reality of the involved biomechanical factors. In a bibliographical review, it was verified that most of the books and articles found do not present detailed information about the prediction of life based on analyzes of multiaxial fatigue that use the FEM to calculate the dental prostheses. The objective of this research was to propose a computational numerical model using the FEM to evaluate the life to the fatigue in dental prostheses submitted to multiaxial loads. For this, we used the manipulation of acquired images, normative experimental tests, Finite Element analysis (FEA) in the prediction of life to the fatigue applied in either uniaxial or multiaxial loading, the counting of the fatigue damage in multiaxial amplitude variable loading, optimization and implementation of the subroutine for the APDL -MATLAB interfaces. The results showed that, through the techniques of image data acquisition (Micro-CT) and mechanical measurements combined with numerical methods, it is possible to model a complex structure such as a dental prostheses.
2

Discrete choice analysis of preferences for dental prostheses

Zhang, Shanshan January 2014 (has links)
Background: Tooth loss has a negative impact on patients’ general health and wellbeing. Dental prostheses can restore oral function, aesthetics and improve oral health related quality of life. Preferences for dental prostheses cannot be fully captured using existing clinical studies and questionnaires. Discrete choice experiment (DCE) is a novel method in health economics to elicit people’s preference for treatments and it allows the researcher to integrate all aspects relevant to treatment into evaluation and measurement of interrelationship between factors. The aim of this PhD thesis is to use a mixed method of DCE and qualitative interviews to analyse dentists and patient’s preferences for dental prosthesis choices in replacing missing teeth. Methods: Discrete choice experiment questionnaires were developed, describing dental prosthdontic treatments in multi-dimensions, including outcome, process and economic factors. Survey and analysis using the questionnaires were conducted with dentists and patients in Edinburgh. Qualitative interviews with Edinburgh dentists and patients were carried out to derive factors to aid the DCE questionnaire design and provide in-depth understanding of DCE results. Systematic reviews were performed to summarise existing evidence on prosthesis evaluation in traditional quantitative studies and perception of prostheses in qualitative interviews. The current application of DCEs in dentistry was also systematically reviewed. Results: Treatment longevity was identified as the most important factor for dentists and patients’ treatment decisions of anterior missing tooth replacements, followed by appearance and chewing function. Dentists put more value on fixation/comfort and treatment procedure than patients. Patients cared about cost of treatment whereas dentists were relatively insensitive. Gender, age and treatment experience significantly influenced patients’ preference for treatment characteristics. Dental implant supported crown was preferred by dentists, whereas patients gave higher utility to traditional prosthodontic treatments. The monetary benefit of fixed dental prostheses ranged from £1856 -£3848 for patients, far exceeding their willingness-to-pay (WTP), which was £120 - £240. Dentists were willing to pay £600-£3000, more than the perceived benefit £503 to £1649. Qualitative study identified the above factors and provided interpretation of DCE results. Problems in the dental care system related to referral and training for dental implant treatments were raised. Discussion: This thesis is the first DCE application in dentistry evaluating and comparing dentists and patients preferences for missing tooth replacements. Dentists and patients’ preferences were elicited qualitatively and qualitatively integrating multidimensional factors. Patients’ preference for treatments, monetary benefit and WTP were demonstrated to be different from dentists’. Treatment benefits exceeded patients WTP for fixed dental prostheses.
3

Análise de fadiga em próteses odontológicas implanto-suportada sob carregamento multiaxiais. / Analysis of failure in implanto-supported odontological prostheses under multiaxial loading.

Henry Figueredo Losada 13 November 2018 (has links)
Próteses odontológicas são estruturas que restituem a função mastigatória e substituem componentes dentários danificados. A maioria dos estudos em próteses odontológicas que envolve métodos analíticos clássicos de análise de estrutura são inviáveis e situações nas quais a experimentação é dificultosa. Estas próteses, sob condições reais de carregamentos cíclicos (mastigação), são repetidamente sujeitas à estados de tensões multiaxiais cíclicas. Neste sentido, a natureza cíclica do carregamento, a qual os componentes das próteses são submetidos, sugere que o modo de falha por fadiga possui maior relevância neste tipo de estrutura. O desenvolvimento da computação eo aumento das capacidades de processamentos tem permitido maior implementação dos métodos numéricos, como o Métodos de Elementos Finitos (MEF). Através deste método (MEF) se realiza a modelagem do comportamento mecânico ajustadas à realidade física dos fatores biomecânicos envolvidos. Em uma revisão bibliográfica, verificou-se que a maioria dos livros e artigos encontrados não apresentam informação detalhadas sobre a previsão da vida baseado em análises de fadiga multiaxial que utilizem o MEF para cálculo das próteses odontológicas. O objetivo deste trabalho foi propor um modelo numérico computacional utilizando o MEF para avaliar a vida à fadiga em próteses odontológicas submetidas a carregamentos multiaxiais. Para isso, foi empregada a manipulação de imagens adquiridas, ensaios experimentais normativos, Análise por Elemento Finitos (FEA) na previsão de vida à fadiga aplicada tanto em carregamento uniaxial ou multiaxial, a contabilização do dano por fadiga em carregamento multiaxial de amplitude variáveis, otimização e implementação de subrotina para as interfaces APDL -MATLAB. Os resultados mostraram que, através das técnicas de aquisição de dados de imagens (Micro-CT) e medições mecânicas combinadas com métodos numéricos consegue-se modelar uma estrutura complexa como uma prótese dental. / Dental prostheses are structures that restore the masticatory function and replace damaged dental components. Most studies on dental prostheses involve that classical analytical methods of structure analysis are infeasible and situations in which experimentation is difficult. These prostheses, under real conditions of cyclic loading (chewing), are repeatedly subjected to cyclic multiaxial stress states. In this sense, the cyclical nature of the loading, to which the components of the prosthesis are submitted, suggests that the fatigue failure mode has greater relevance in this type of structure. The development of computation and the increase of processing capacities have allowed greater implementation of numerical methods, such as Finite Element Methods (FEM). Through this method (FEM) it is performed the modeling of the mechanical behavior which is adjusted to the physical reality of the involved biomechanical factors. In a bibliographical review, it was verified that most of the books and articles found do not present detailed information about the prediction of life based on analyzes of multiaxial fatigue that use the FEM to calculate the dental prostheses. The objective of this research was to propose a computational numerical model using the FEM to evaluate the life to the fatigue in dental prostheses submitted to multiaxial loads. For this, we used the manipulation of acquired images, normative experimental tests, Finite Element analysis (FEA) in the prediction of life to the fatigue applied in either uniaxial or multiaxial loading, the counting of the fatigue damage in multiaxial amplitude variable loading, optimization and implementation of the subroutine for the APDL -MATLAB interfaces. The results showed that, through the techniques of image data acquisition (Micro-CT) and mechanical measurements combined with numerical methods, it is possible to model a complex structure such as a dental prostheses.
4

Avaliação "in vitro " da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos /

Bottino, Marco Antonio. January 1998 (has links)
Resumo: Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study assessed the quality of cervical adaptation in full metal crowns, with a variation in: a) the type of cervical preparation- beveled shoulder, 135-degree preparation, 90-degree shoulder, chamfer and knife edge; b) internal surfaces of the crowns with or without relief; c) the types of luting agents and their commercial brands- Harvard zinc phosphate, Ketac-Cem glass ionomer, Durelon zinc polycarboxylate and Panavia Ex resinous. Initially, machined stainless steel models were made according to each experimental margin design. Stainless steel metal caps were prepared with or without a 30-micrometer spacing of their internal surfaces, kept away 0.5 mm of the cervical end limit; they were precisely fitted, making a set with exact adaptation and seating. The caps were cemented on the specimens by means of different luting agents , handled according to the manufacturer's instructions. Methods were developed to reuse the specimens. Precise measures were obtained by preventing caps from moving during measurements. The conclusions were: a) the best mean of cervical adaptation, similar to each other , was obtained in standard models with preparations : knife edge, 1350 shoulder and chamfer; b) the worst mean of cervical adaptation, similar between them , was obtained in standard models with: straight shoulder and beveled shoulder; c) there was a significant improvement in adaptation when the metal caps were cemented with relief in their internal surface; d) cements presented decreasing cervical adaption, in the following order: Ketac-Cem, Harvard, Durelon and Panavia Ex; and, e) the methodology used allowed work with positive values of cervical adaptation.
5

Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas / Evaluation of failure mode of ceramic crowns with and without framework design modification.

Lorenzoni, Fabio Cesar 25 March 2009 (has links)
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterada) das coroas metalocerâmicas (MC) e das ceramocerâmicas (CC), denominadas de MCSA e CCSA para as I.E. com desenho padrão e MCCA e CCCA para as com alteração no seu desenho. As infraestruturas com desenho padrão apresentaram espessura de 0,5mm em todas as suas paredes e as com alteração no desenho apresentaram a cinta lingual com 2,0mm de altura e postes proximais com 3,5mm de altura e as demais áreas com 0,5mm de espessura. As coroas ceramocerâmicas consistiam do sistema à base de alumina (In-Ceram Alumina slip cast) e as infraestruturas das coroas metalocerâmicas foram fabricadas com metal não nobre (Ni-Cr). Todas as coroas foram cimentadas com cimento resinoso Rely X ARC sobre uma réplica do preparo de resina composta, a qual teve a proposta de simular o módulo de elasticidade encontrado na dentina. Estas coroas foram submetidas ao teste de resistência à fadiga, ciclagem dinâmica, por 106 ciclos ou até que qualquer tipo de fratura fosse observada, com carga variando entre 30-300N. A força foi aplicada axialmente entre as vertentes palatina e vestibular, com endentador metálico esférico. Em intervalos de 125.000 as coroas eram verificadas à procura de danos com auxílio de estereomicroscopia. As coroas que não sofreram fraturas foram polidas sequencialmente e cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. O teste Kruskal Wallis foi utilizado para verificar se houve diferença estatisticamente significante entre os materiais e o teste de Student-Newman-Keusl foi utilizado para as comparações múltiplas. Diferenças estatisticamente significante foi encontrada entre materiais e desenhos, entretanto, os grupos com I.E. metálica (MCCA e MCSA) não apresentaram diferença estatisticamente significante. O grupo CCCA mostrou diferença estatisticamente significante em relação ao grupo CCSA. A presença do metal na infraestrutura foi preponderante na resistência à fadiga. A alteração no desenho da infraestrutura cerâmica provou ser superior em relação ao desenho sem alteração. / Ceramic crowns have been widely used, however, problems related to brittle fracture of these materials persist, especially in the posterior area. The present study tested the null hypothesis that there were no differences in fatigue resistance related to the framework design as well as to the materials used. One maxillary molar was prepared, reproducing the complex morphology of a dental preparation, to receive metal-ceramic and all-ceramic crowns. Four groups (n=10) were established based on framework designs (standard and modified) for metal-ceramic (MC) and all-ceramic (CC) crowns, named as MCSA and CCSA for standard framework designs and MCCA and CCCA for the proposed framework design modifications. On the standard design, frameworks presented 0.5mm thick walls and those with design modification a 0.5mm thick framework with a vertical increase of 2.0mm lingual and 3.5mm proximal walls. All-ceramic frameworks were made with In-Ceram Alumina slip cast and the metal-ceramic frameworks were made with nickel-chromium alloy. All crowns were cemented with resin cement (Rely X ARC) on resin composite replicas, witch have an elastic modulus similar to dentin. They were subjected to dynamic cycling fatigue test (106 cycles or until fracture), at ranging load of 30-300N. Load was located between the buccal and lingual cuspals of the crowns. At 125.000 cycles intervals, crowns were analysed under a stereomicroscopy to search for damages. Crowns without fracture were polished sequentially and received scores according to the failure mode. Kruskal Wallis test was used to check if there were a significant differences between the framework design and materials (metal and ceramic) and the Student-Newman-Keuls was used for multiple comparisons. Significant differences were found between materials and designs, however, both metal frameworks (MCCA e MCSA) were similar. CCCA group showed higher survival than CCSA group. The metal presence in the framework seemed to improve the resistance to fatigue test. However, the design modification in ceramics achieved better results than the standard design.
6

Avaliação da resistência flexural entre diferentes métodos de soldagem: chama direta - TIG - Laser / Evaluation of the flexural strength among different welding methods: Brazing - TIG - Laser.

Silva, Jeovan da 06 November 2007 (has links)
A técnica de soldagem apresenta vantagem de união de partes metálicas que permite melhora na adaptação e uniformidade na distribuição das forças mastigatórias, minimizando falhas no tratamento reabilitador. O objetivo foi avaliar a resistência flexural entre três métodos de soldagem diferentes: Chama Direta a maçarico, método TIG - Tungstênio gás inerte (Soldadora NTY - Kernit, Brasil) e o método de solda a Laser (Soldadora Desktop - Dentaurum, Alemanha) comparando a um grupo controle (Monobloco). Os espécimes cilíndricos foram obtidos a partir de canais de cera pré-fabricados com 3mm de diâmetro e 30mm de comprimento, fundidos em liga de Ni-Cr e seccionados transversalmente, formando os grupos T1 e L1. Depois da secção, dez espécimes dos grupos L e T receberam chanfros em 45° para preenchimento, formando os grupos (L2 e T2). As extremidades foram unidas com resina acrílica obedecendo a uma distância pré-determinada, de 0,3mm para o grupo chama direta, 0,1mm para o grupo TIG e juntas do tipo topo a topo para o grupo laser. Os corpos foram incluídos e soldados de acordo com a proposição. Após a soldagem os corpos de prova foram torneados e levados ao teste de flexão. Os dados foram submetidos aos testes estatísticos (ANOVA e Student-Newman-Keuls - p <0,05) para comparações múltiplas. De acordo com os resultados (MPa) o grupo M (1796,55) obteve o maior valor, seguindo pelo grupo C(1370,56), ficando o grupo T1(990,84) com o valor menor. Não houve diferença estatística entre os grupos soldados, existindo somente diferença entre os grupos de teste para o grupo controle em monobloco. No entanto podemos afirmar que o preenchimento parece influenciar discretamente os resultados da resistência flexural no grupo TIG. Conclui-se que o método TIG produz resultado semelhante ao laser e a chama direta, o que é clínica e operacionalmente importante. / The welding technique presents advantage of union of metallic parts that improves the adaptation and appropriate distribution of the bite forces, minimizing flaws in the dental prostheses. The objective was to evaluate the flexural strength in different welding methods: Brazing; Laser (Welder Desktop - Dentaurum, Germany) and Tungsten inert gas - TIG (Welder NTY - Kernit, Brazil), comparing to a control group (non-welded). The cylindrical specimens were obtained from prefabricated wax conduits with 3mm of diameter and 30mm of length, melted in Ni-Cr alloys and split up transversally, forming the groups T1 and L1. After of the section the groups L and T received slices in 45° for fulfill, forming the groups (L2 and T2). The extremities were united with acrylic resin obeying a predetermined distance, from 0,3 mm to the brazing group, 0,1 mm to the TIG group, and in the laser group there wasn\' t any space between the extremities of jointing. The specimes were included and welding in agreement with the proposition, turned and conducted to the flexion test. The data were submitted to the statistical test (ANOVA and Student-Newman-Keuls - p<0,05) for multiple comparisons. According to the results (MPa) the control group (1796,55) obtained the largest average value, followed by the brazing group (1370,56), being the group T1(990,84) with the smallest value. In terms of statistics there was no difference between the groups with welding, existing only difference among the tested groups for the control group. However, we can affirm that the completion seems to influence the results of the resistance flexural discreetly in the TIG group. It can be concluded that the TIG method produces similar result to the laser and the brazing, what is clinical and important operationally.
7

Avaliação da resistência flexural entre diferentes métodos de soldagem: chama direta - TIG - Laser / Evaluation of the flexural strength among different welding methods: Brazing - TIG - Laser.

Jeovan da Silva 06 November 2007 (has links)
A técnica de soldagem apresenta vantagem de união de partes metálicas que permite melhora na adaptação e uniformidade na distribuição das forças mastigatórias, minimizando falhas no tratamento reabilitador. O objetivo foi avaliar a resistência flexural entre três métodos de soldagem diferentes: Chama Direta a maçarico, método TIG - Tungstênio gás inerte (Soldadora NTY - Kernit, Brasil) e o método de solda a Laser (Soldadora Desktop - Dentaurum, Alemanha) comparando a um grupo controle (Monobloco). Os espécimes cilíndricos foram obtidos a partir de canais de cera pré-fabricados com 3mm de diâmetro e 30mm de comprimento, fundidos em liga de Ni-Cr e seccionados transversalmente, formando os grupos T1 e L1. Depois da secção, dez espécimes dos grupos L e T receberam chanfros em 45° para preenchimento, formando os grupos (L2 e T2). As extremidades foram unidas com resina acrílica obedecendo a uma distância pré-determinada, de 0,3mm para o grupo chama direta, 0,1mm para o grupo TIG e juntas do tipo topo a topo para o grupo laser. Os corpos foram incluídos e soldados de acordo com a proposição. Após a soldagem os corpos de prova foram torneados e levados ao teste de flexão. Os dados foram submetidos aos testes estatísticos (ANOVA e Student-Newman-Keuls - p <0,05) para comparações múltiplas. De acordo com os resultados (MPa) o grupo M (1796,55) obteve o maior valor, seguindo pelo grupo C(1370,56), ficando o grupo T1(990,84) com o valor menor. Não houve diferença estatística entre os grupos soldados, existindo somente diferença entre os grupos de teste para o grupo controle em monobloco. No entanto podemos afirmar que o preenchimento parece influenciar discretamente os resultados da resistência flexural no grupo TIG. Conclui-se que o método TIG produz resultado semelhante ao laser e a chama direta, o que é clínica e operacionalmente importante. / The welding technique presents advantage of union of metallic parts that improves the adaptation and appropriate distribution of the bite forces, minimizing flaws in the dental prostheses. The objective was to evaluate the flexural strength in different welding methods: Brazing; Laser (Welder Desktop - Dentaurum, Germany) and Tungsten inert gas - TIG (Welder NTY - Kernit, Brazil), comparing to a control group (non-welded). The cylindrical specimens were obtained from prefabricated wax conduits with 3mm of diameter and 30mm of length, melted in Ni-Cr alloys and split up transversally, forming the groups T1 and L1. After of the section the groups L and T received slices in 45° for fulfill, forming the groups (L2 and T2). The extremities were united with acrylic resin obeying a predetermined distance, from 0,3 mm to the brazing group, 0,1 mm to the TIG group, and in the laser group there wasn\' t any space between the extremities of jointing. The specimes were included and welding in agreement with the proposition, turned and conducted to the flexion test. The data were submitted to the statistical test (ANOVA and Student-Newman-Keuls - p<0,05) for multiple comparisons. According to the results (MPa) the control group (1796,55) obtained the largest average value, followed by the brazing group (1370,56), being the group T1(990,84) with the smallest value. In terms of statistics there was no difference between the groups with welding, existing only difference among the tested groups for the control group. However, we can affirm that the completion seems to influence the results of the resistance flexural discreetly in the TIG group. It can be concluded that the TIG method produces similar result to the laser and the brazing, what is clinical and important operationally.
8

Efeito da altura da união implante/componente protético sobre os tecidos periimplantares : estudo clínico e radiográfico em cães /

Paula, Wagner Nunes de. January 2008 (has links)
Resumo: O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / Abstract: The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Walter Martins Junior / Banca: Luis Antonio Borelli Barros / Mestre
9

Efeito da altura da união implante/componente protético sobre os tecidos periimplantares: estudo clínico e radiográfico em cães

Paula, Wagner Nunes de [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-28Bitstream added on 2014-06-13T20:36:52Z : No. of bitstreams: 1 paula_wn_me_arafo.pdf: 549135 bytes, checksum: 1cd91d5b53b64bec46b8e5ace0efab34 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC.
10

Avaliação do modo de falha de coroas cerâmicas com e sem alteração do desenho das infraestruturas / Evaluation of failure mode of ceramic crowns with and without framework design modification.

Fabio Cesar Lorenzoni 25 March 2009 (has links)
Coroas cerâmicas têm sido amplamente utilizadas, entretanto, problemas relacionados com a fratura destes materiais persistem principalmente nos sistemas ceramocerâmicos na região de molar. As hipóteses nulas testadas foram que o desenho da infraestrutura e o tipo de material não terão efeito significante na resistência à fadiga. Coroas metalocerâmicas e ceramocerâmicas foram fabricadas sobre o preparo de um molar superior, o qual reproduzia a complexa morfologia dos preparos dentários. Quatro grupos foram estabelecidos (n=10 por grupo) baseados no desenho das infraestruturas (padrão ou alterada) das coroas metalocerâmicas (MC) e das ceramocerâmicas (CC), denominadas de MCSA e CCSA para as I.E. com desenho padrão e MCCA e CCCA para as com alteração no seu desenho. As infraestruturas com desenho padrão apresentaram espessura de 0,5mm em todas as suas paredes e as com alteração no desenho apresentaram a cinta lingual com 2,0mm de altura e postes proximais com 3,5mm de altura e as demais áreas com 0,5mm de espessura. As coroas ceramocerâmicas consistiam do sistema à base de alumina (In-Ceram Alumina slip cast) e as infraestruturas das coroas metalocerâmicas foram fabricadas com metal não nobre (Ni-Cr). Todas as coroas foram cimentadas com cimento resinoso Rely X ARC sobre uma réplica do preparo de resina composta, a qual teve a proposta de simular o módulo de elasticidade encontrado na dentina. Estas coroas foram submetidas ao teste de resistência à fadiga, ciclagem dinâmica, por 106 ciclos ou até que qualquer tipo de fratura fosse observada, com carga variando entre 30-300N. A força foi aplicada axialmente entre as vertentes palatina e vestibular, com endentador metálico esférico. Em intervalos de 125.000 as coroas eram verificadas à procura de danos com auxílio de estereomicroscopia. As coroas que não sofreram fraturas foram polidas sequencialmente e cada corpo de prova recebeu escores de acordo com o tipo de falha apresentada. O teste Kruskal Wallis foi utilizado para verificar se houve diferença estatisticamente significante entre os materiais e o teste de Student-Newman-Keusl foi utilizado para as comparações múltiplas. Diferenças estatisticamente significante foi encontrada entre materiais e desenhos, entretanto, os grupos com I.E. metálica (MCCA e MCSA) não apresentaram diferença estatisticamente significante. O grupo CCCA mostrou diferença estatisticamente significante em relação ao grupo CCSA. A presença do metal na infraestrutura foi preponderante na resistência à fadiga. A alteração no desenho da infraestrutura cerâmica provou ser superior em relação ao desenho sem alteração. / Ceramic crowns have been widely used, however, problems related to brittle fracture of these materials persist, especially in the posterior area. The present study tested the null hypothesis that there were no differences in fatigue resistance related to the framework design as well as to the materials used. One maxillary molar was prepared, reproducing the complex morphology of a dental preparation, to receive metal-ceramic and all-ceramic crowns. Four groups (n=10) were established based on framework designs (standard and modified) for metal-ceramic (MC) and all-ceramic (CC) crowns, named as MCSA and CCSA for standard framework designs and MCCA and CCCA for the proposed framework design modifications. On the standard design, frameworks presented 0.5mm thick walls and those with design modification a 0.5mm thick framework with a vertical increase of 2.0mm lingual and 3.5mm proximal walls. All-ceramic frameworks were made with In-Ceram Alumina slip cast and the metal-ceramic frameworks were made with nickel-chromium alloy. All crowns were cemented with resin cement (Rely X ARC) on resin composite replicas, witch have an elastic modulus similar to dentin. They were subjected to dynamic cycling fatigue test (106 cycles or until fracture), at ranging load of 30-300N. Load was located between the buccal and lingual cuspals of the crowns. At 125.000 cycles intervals, crowns were analysed under a stereomicroscopy to search for damages. Crowns without fracture were polished sequentially and received scores according to the failure mode. Kruskal Wallis test was used to check if there were a significant differences between the framework design and materials (metal and ceramic) and the Student-Newman-Keuls was used for multiple comparisons. Significant differences were found between materials and designs, however, both metal frameworks (MCCA e MCSA) were similar. CCCA group showed higher survival than CCSA group. The metal presence in the framework seemed to improve the resistance to fatigue test. However, the design modification in ceramics achieved better results than the standard design.

Page generated in 0.1002 seconds