• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 81
  • 12
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 95
  • 95
  • 29
  • 27
  • 16
  • 15
  • 14
  • 12
  • 11
  • 11
  • 8
  • 8
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Dentin bonding SEM comparison of dentin surface and resin-dentin interface in primary and permanent teeth : a thesis submitted in partial fulfillment ... for the degree of Master of Science (Pediatric Dentistry) ... /by Jacques Eduardo Nör.

Nör, Jacques Eduardo. January 1994 (has links)
Thesis (M.S.)--University of Michigan, 1994.
62

Contraction gaps around dental composite resin restorations

Torstenson, Bodil. January 1988 (has links)
Thesis (doctoral)--Karolinska Institutet, Stockholm, 1988. / Extra t.p. with thesis statement inserted. Includes bibliographical references.
63

Avaliação da capacidade de resinas compostas contendo trimetafosfato de sódio associado ou não ao fluoreto em reduzir a desmineralização e promover a remineralização in vitro

Tiveron, Adelisa Rodolfo Ferreira [UNESP] 18 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-18Bitstream added on 2014-06-13T19:43:58Z : No. of bitstreams: 1 tiveron_arf_dr_araca.pdf: 718101 bytes, checksum: f99be1f1b4c33616a91ef5b5f42830b4 (MD5) / Fgm Produtos Odontologicos Ltda. / O objetivo deste estudo foi verificar a capacidade de resinas compostas contendo trimetafosfato de sódio (TMP) associado ou não ao fluoreto em reduzir a desmineralização e promover a remineralização do esmalte in vitro. Foram selecionados 156 blocos de esmalte de incisivos bovinos (4x3x3 mm), pelo teste de dureza de superfície inicial e confeccionados 240 corpos-de-prova das resinas compostas. Estudo para verificar a redução da desmineralização (DES>RE): foram definidos os seguintes grupos: sem TMP e fluoreto de sódio; sem TMP e com fluoreto de sódio a 1,6%; TMP 1,5%, 14,1% ou 36,8% com ou sem fluoreto de sódio a 1,6%. Noventa e seis corpos-de-prova foram adaptados aos blocos de esmalte e submetidos às ciclagens de pH. A seguir, analisou-se a dureza de superfície e em secção longitudinal e a concentração de F no esmalte. Foi determinada a liberação de F e TMP (n = 6) e a dureza (n = 6) das resinas. Testes paramétricos e não paramétricos foram realizados, após a verificação da homocedasticidade dos dados (p < 0,05). A presença de F no esmalte foi similar nas resinas fluoretadas (p > 0,05), porém maior que os demais grupos (p < 0,05). A associação TMP 14,1% e F apresentou menor desmineralização com maior intensidade na região superficial da lesão (p < 0,05). A presença de TMP aumentou a liberação de F e reduziu a dureza dos materiais. Estudo para verificar a capacidade de remineralização (RE>DES): lesão de cárie artificial foi induzida nos 60 blocos e após determinou-se a dureza de superfície pós-desmineralização. Os grupos foram definidos: sem TMP e fluoreto de sódio; sem TMP e com fluoreto de sódio a 1,6%; com 14,1% de TMP com ou sem fluoreto de sódio a 1,6%. Após os corpos-de-prova... / The purpose of this in vitro study was to verify the capacity of composite resins containing sodium trimetaphosphate (TMP) associated or not with fluoride for reducing demineralization and promoting remineralization on enamel. One hundred fifty-six enamel blocks (4x3x3 mm) were prepared from extracted bovine incisors and selected through the initial surface hardness test and then 240 specimens of the composite resins were confectioned. Analysis of the demineralization reduction (DES>RE): The following groups were defined: without TMP and sodium fluoride; without TMP and with 1.6% sodium fluoride; 1.5%, 14.1% or 36.8% TMP with or without 1.6% sodium fluoride. A total of 96 specimens were adjusted to the enamel blocks and submitted to pH-cyclings. Following, superficial and cross-sectional hardness and F concentration on enamel were verified. F and TMP release (n = 6) and hardness (n = 6) of the composite resins were determined. Parametric and non-parametric tests were performed, after the verification of data homoscedasticity (p < 0.05). The presence of F on enamel was similar in fluoride resins (p > 0.05), but higher than the other groups (p < 0.05). The association of 14.1% TMP and F presented lower demineralization with the higher intensity on the lesion surface (p < 0.05). The presence of TMP increased the F release and decreased the materials’ hardness. Analysis of the remineralization capacity (RE>DES): Artificial carious lesions were induced on the 60 blocks and, then, the post-demineralization surface hardness was determined. The groups were defined: without TMP and sodium fluoride; without TMP and with 1.6% sodium fluoride; with 14.1% TMP and with or without 1.6% sodium fluoride. Specimens... (Complete abstract click electronic access below)
64

Citotoxidade direta e transdentinária de sistemas adesivos com diferentes graus de hidrofilia sobre células odontoblastóides

Bianchi, Luciana [UNESP] 19 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-19Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 bianchi_l_me_arafo.pdf: 1440402 bytes, checksum: e46b54f688f969e58ca558c0a1176228 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo geral desse trabalho, dividido em dois experimentos (capítulos 1 e 2), foi avaliar a citotoxicidade de sistemas adesivos experimentais (SAEs), com diferentes graus de hidrofilia, e do etanol como solução de solvatação da dentina, sobre células odontoblastóides. No capítulo 1, discos de papel filtro esterilizados foram impregnados com 10 μL de cada SAE (n=22): R1, R2, R3, R4 e R5 (em ordem crescente de hidrofilia), seguido de fotoativação. Os discos foram individualmente imersos em meio de cultura DMEM para obtenção de extratos (DMEM + componentes liberados dos SAEs), os quais foram posteriormente aplicados sobre células MDPC-­‐23 em cultura. Discos não impregnados (R0) serviram como controle. Foram avaliados o metabolismo celular (teste de MTT), a expressão de proteína total (PT) e a atividade de fosfatase alcalina (FA), além do tipo de morte celular (citometria de fluxo) e grau de conversão monomérica (FTIR) dos SAEs. Os dados de cada variável resposta do estudo foram analisados por testes de Kruskal-­‐Wallis e Mann-­‐Whitney (α=0,05). Considerando R0 como 100%, foi observada redução do metabolismo celular de 36,4%, 3,1%, 0,2%, 21,5% e 65,7%, respectivamente para R1, R2, R3, R4 e R5. Apenas R1 e R5 diferiram estatisticamente do controle. Para PT, R1, R4 e R5 tiveram expressão estatisticamente inferior ao controle, enquanto que a atividade de FA foi significativamente reduzida por R1 e R5. Esses mesmos SAEs juntamente com R4 induziram as maiores porcentagens de morte... / The overall aim of this study, divided into two experiments, was to evaluate the cytotoxicity of experimental adhesive systems (EAS) with different hydrophilicity, and ethanol as a dentin solvation solution, on odontoblast-­‐like cells. In the first experiment, sterilized filter paper discs were impregnated with 10 μL of each EAS: R1, R2, R3, R4 and R5 (in increasing rank of hydrophilicity), followed by light activation. The paper discs were individually immersed in DMEM culture medium for obtaining the extracts (DMEM + released components of EAS), which were applied on MDPC-­‐23 cells in culture. Non-­‐impregnated paper discs (R0) were used as control. Cell metabolism (MTT assay), total protein expression (TP) and alkaline phosphatase activity (ALP) were assessed, in addition to the type of cell death (flow cytometry) and the degree of monomer conversion (FTIR). Data for each response variable were submitted to Kruskal-­‐Wallis and Mann-­‐Whitney tests (α=0.05). Compared to the control (100%), cell metabolism was decreased by 36.4%, 3.1%, 0.2%, 21.5% and 65.7% for R1, R2, R3, R4 and R5, respectively. However, only R1 and R5 differed from the control. R1, R4 and R5 decreased the expression of TP compared to the control, whereas only R1 and R5 significantly reduced the activity of ALP. The later EAS plus R4 caused the highest percentages of cell death by necrosis. A higher percentage of monomer conversion was detected as a function of the hydrophilicity. According to the experimental conditions, it could be... (Complete abstract click electronic access below)
65

Avaliação da porosidade interna e da rugosidade de superficie de resinas compostas para dentes posteriores submetidas a escovação

Santos, Paulo Henrique dos 12 December 2000 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T10:02:09Z (GMT). No. of bitstreams: 1 Santos_PauloHenriquedos_M.pdf: 3739962 bytes, checksum: 4f966540d6526543127025aacad09ae1 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste estudo foi verificar a porosidade interna, a rugosidade de superficie de resinas compostas para restauração em dentes posteriores submetidas a ensaio mecânico de escovação e a eficácia de métodos de recuperação de lisura superficial. Os materiais utilizados foram as resinas compostas específicas para restauração em dentes posteriores: Prodigy Condensável@ (KerrISybron) e Alert@ (JenericlPentron); resinas compostas para utilização em dentes anteriores e posteriores: Z100@ (3M) e Definite@ (Degussa) e o selante de superficie Protect-It@ (JenericlPentron). Para avaliação da rugosidade de superficie, 10 corpos-de-prova de cada material foram confeccionados à temperatura de 23 ::t 1°e e umidade relativa do ar ambiental de 50 ::t 5% , utilizando uma matriz metálica com 2mm de espessura por 4mm de diâmetro. Após 24 horas, foi realizado o polimento dos materiais utilizando o sistema de acabamento e polimento Sof-Lex@ (3M) e uma das superfícies dos corpos-de-prova foi coberta com o selante de superficie e a outra não. Todos os corpos-de-prova foram levados individualmente ao rugosímetro (Surfcorder SE 1700) para verificação da rugosidade inicial das superfícies, antes de serem submetidos a movimentos lineares de escovação, com velocidade de 250 movimentos por minuto, totalizando 30.000 ciclos por superficie, num período de duas horas. Após este período, foi realizada a segunda leitura da rugosidade em todas as superfícies, sendo que, em seguida, uma delas foi recoberta com selante de superfície e a rugosidade foi novamente aferida. Na outra, foram tomadas mais duas leituras da rugosidade, uma após o repolimento e outra após a aplicação do selante. Para a avaliação da porosidade, os corpos-de-prova de cada material foram seccionados com disco de óxido de silício, incluídos em resina acrílica de ativação química, abrasonados com lixas de granulação de magnitude decrescente (200, 400 e 600) e imersos em tinta Nankin (Acrilex) por 12 horas. A quantidade de poros na área seccionada foi verificada com auxilio da lupa estereoscópica Carl-Zeiss (Alemanha), com aumento de 64 vezes e a área percentual foi calculada utilizando o programa Adobe Photoshop versão 4. O. Os resultados foram submetidos à análise de variância e ao teste de Tukey, em nível de 5% de probabilidade. Os resultados mostraram que: (1) houve aumento da rugosidade superficial em todos os compósitos após o ensaio de escovação, à exceção do Prodigy Condensávet<B>; (2) o Alert@ apresentou maior rugosidade superficial dentre as resinas o Alert@ e Definite@, sem promover efeito nos materiais Z1O0@ e Prodigy Condensável@; estudadas; (3) o selante de superficie diminuiu a rugosidade provocada pela escovação para (4) o melhor método de recuperação da lisura superficial após desgaste abrasivo foi o repolimento, podendo associá-Io à aplicação do selante, especialmente para o Alert@ e (5) a maior porosidade foi obtida para o Alert@, seguido pelo Prodigy Condensável@, quando comparados com o Definite@ e Z100@ / Abstract: The aim of this study was to verify the internal porosity, the surface roughness of posterior composite resins submitted on mechanical toothbrushing and the efficency of methods for superficial smoothness recuperation. The materials evaluated were two posterior composite resms: Prodigy Condensable@ (Kerr/Sybron) and Alert@ (Jeneric/Pentron); two universal composite resins: Z100@ (3M) and Definite@ (Degussa) and the surface penetrating sealant Protect-It@ (Jeneric/Pentron). For the measurement of surface rourghness, ten specimens of each material were made at 23 :t 1°C of room temperature and 50 :t 5% of relative humidity, using metallic matrice (2mm in height, 4mm in diameter). After 24 hours, the specimens were polished using Sof-Lex system@ (3M) and one of the surfaces was covered with the surface sealant. AlI the specimens were taken to the rugosimeter (Surfcorder SE 1700) to examine the initial surface roughness, before the mechanical toothbrushing at constant speed of 250 strokes per minute, during 2 hours, totalizing 30.000 cyc1es. The surface roughness was then measured one more time, one of the surfaces was recovered with the surface sealant and this surface was examined again. On the other surface, two more measurements were made, one after the repolishing and other after the surface sealant application. For evaluation of porosity, the specimens were _cut with silicon disc, inc1uded in chemical acrillic resin, abrasioned with sandpapers (200, 400 and 600) and immersed in Nankin corant (Acrilex) for 12 hours. The porosity was quantified in a stereoscopic microscopy Carl-Zeiss (Germany), with 64 x of magnification, and the percentual area was calculated using the Adobe Photoshop 4.0 programo The results were subject to analysis of variance and to Tukey' s test at 5% significant leveI and showed that: (1) the roughness surface increased in all of the materiais after the mechanical toothbrushing, except Prodigy Condensable@; (2) Alert@ showed the most roughness surface; (3) the surface penetrating sea1ant decreased the roughness after the mechanical toothbrushing for Alert@ and Definite@ without any effect for Z1O0@ and Prodigy Condensable@; (4) the best method for superficial smoothness recuperation after abrasion specia11y for the Alert@; (5) Alert@ showed the most porosity, followed by Prodigy was the repolishing, which can be associated with the application of surface sealant, Condensable@, when compared with Definite@ and ZlOO@ / Mestrado / Mestre em Materiais Dentários
66

Resistencia de união de resinas compostas de dupla ativação ao titanio c.p.

Schneider, Rafael 02 September 2001 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:29:44Z (GMT). No. of bitstreams: 1 Schneider_Rafael_M.pdf: 2810687 bytes, checksum: 9d979a028f770e751472cb0bb9d83d72 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a resistência à tração de discos de Titânio comercialmente puro unidos às resinas compostas de ativação química e física para fixação Panavia Fluoro Cement e Rely X ARC. Para a realização do experimento, 120 discos de Titânio foram fundidos, embutidos em tubos de PVC com resina acrílica autopolimerizável, planificados e polidos com lixas d'água de granulações 320, 400 e 600. Uma área circular central com 4mm de diâmetro da superfície dos discos de Titânio foi submetida ao jateamento com óxido de Alumínio (50 mm) e os discos limpos em água sob ultra-som por 10 minutos. Os espécimes foram divididos em 4 Grupos de 30 cada. Nos Grupos 1 e 3 os discos foram unidos aos 10 minutos após o jateamento e os Grupos 2 e 4 vinte e quatro horas após o jateamento. Nos Grupos 1 e 2 os discos de Titânio foram unidos com a resina composta Panavia Fluoro Cement, e os Grupos 3 e 4 com a resina composta Rely X ARe. Após armazenagem em água destilada a 37°C por 24 horas, os corpos-de-prova foram submetidos a ensaio de tração axial em máquina de ensaio universal com velocidade de 0,5 mm/min. Os valores obtidos foram submetidos à análise de variância em nível de significância de 5%. As médias e os desvios padrões dos valores obtidos em MPa foram: Grupo 1: 13,96 (3,60); Grupo 2: 14,76 (7,71); Grupo 3: 13,90 (6,08) e Grupo 4: 18,27 (7,34). Não houve diferença estatística significante entre os grupos testados. A superfície dos corpos-de-prova fraturados foi observada em lupa estereoscópica com aumento de 60 vezes (60X) para a determinação do tipo de fratura provocada pelo ensaio de tração. Um corpo-de-prova de cada Grupo foi selecionado para observação em microscópio eletrônico de varredura. Ocorreu a combinação de falha adesiva entre resina composta e Titânio e coesiva da resina composta para fixação em todos os corpos-de-prova. Porém, nos Grupos I e 2 a falha predominante foi coesiva na resina composta para fixação Panavia Fluoro Cement e nos Grupos 3 e 4 a falha predominante foi adesiva entre a resina composta para fixação Rely X ARC e o Titânio / Abstract: The aim of this study was to evaluate the tensile bond strength of commercially pure Titanium bonded to the luting composite resins Panavia Fluoro Cement and Re1y X ARC. One hundred twenty Titanium discs were casted and embedded in PVC tubes with cold-cured acrylic resin. The edges of the Titanium discs containing tubes were cut and the Titanium discs were grounded on 320, 400 and 600 silicon carbide papers. Then, a 4mm diameter circular area was sandblasted (50 mm Aluminum oxide) and the specimens were ultrasonic cleaned for 10 minutes. The specimens were divided in four Groups with 30 specimens each. In the Groups 1 and 3 the discs were bonded in pairs at ten minutes and in the Groups 2 and 4 twenty-four hours after the sandblasting. The specimens of the Groups 1 and 2 were bonded with Panavia Fluoro Cement and the Groups 3 and 4 with the Rely X are. After the twenty-four hours storage in 37°C water, the bonded paired discs were submitted to the tensile test in a 0,5 mm/minute crosshead speed Instron Universal Machine. The tensile strength values were submitted to the analysis of variance (p=0,05). The means and standard deviations were: Group 1 - 13,96 (3,6); Group 2 - 14,76 (7,71); Group 3 - 13,90 (6,08); Group 4: 18, 27 (7,34). The higher tensile strength value was reached in the Group 4 and the smaller in the Group 3, but there was not statistically significant difference among the alI Groups. The surface of the fractured specimens was observed in a 60 x stereoscopic loupe to determinate the fracture shape. One specimen of each Group was selected to observation in scanning electronic microscopy. The fracture shape in the all Groups was a mixture of cohesive in the composite resin and adhesive failures. However, the predominant failure in the Groups 1 and 2 was cohesive in the composite resin and in the Groups 3 and 4 the predominant failure was adhesive between the composite resin and Titanium / Mestrado / Mestre em Materiais Dentários
67

Efeito dos metodos de fotoativação e dos materiais para facetas indiretas na Dureza Knoop de cimentos resinosos / Effect of different light-curing methods and materials for indirect venners on Knoop hardness of resin cements

Tango, Rubens Nisie 16 February 2005 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:57:43Z (GMT). No. of bitstreams: 1 Tango_RubensNisie_M.pdf: 1265562 bytes, checksum: 8fbd091ba4ed706ead1d52e00f1715f4 (MD5) Previous issue date: 2005 / Resumo: A crescente demanda por restaurações estéticas tem feito com que cerâmicas e compósitos sejam cada vez mais utilizados na reabilitação dental. Para a cimentação de restaurações indiretas confeccionadas com estes materiais, o agente fixador de escolha é o cimento resinoso. Este material pode polimerizar através de ativação química, física ou através de ativação química/física. Contudo, em determinadas situações clínicas a fotoativação deve ser realizada indiretamente através da cerâmica ou do compósito. Por vezes, em casos em que se prima pela estética, os cimentos fotoativados são preferidos devido a maior estabilidade de cor. Entretanto, a ativação química pode garantir polimerização mais efetiva do cimento. Assim, este estudo teve como objetivo avaliar a dureza Knoop do cimento resinoso Enforce, ativado pelo modo dual ou físico, fotoativado diretamente, sob 1,5mm de cerâmica HeraCeram ou compósito Artglass, usando diferentes aparelhos fotoativadores. Para fotoativação foram utilizados os seguintes tempos: luz halógena convencional (XL2500) - HL, por 40s; luz emitida por diodo (Ultrablue Is) - LED, por 40s; e luz emitida por arco de plasma de xenônio (Apollo 95E) - PAC, por 3s. Incisivos bovinos embutidos em resina de poliestireno tiveram suas faces vestibulares planificadas e submetidas à técnica de hibridização. Sobre a área de dentina hibridizada foi assentada uma matriz de borracha (1mm de espessura e 5mm de diâmetro), dentro da qual foi depositado o cimento devidamente espatulado. O disco de um dos materiais para prótese foi assentado sobre este conjunto, procedendo-se então a fotoativação. Após armazenagem por 24h a 37oC, as amostras foram seccionadas para mensuração da dureza (KHN) em 3 regiões distintas: próximo ao material restaurador, próximo à dentina e ao centro. As leituras de dureza foram realizadas em um microdurômetro após aplicação de carga de 50gf por 15s. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey, ambos com a=0,05. Foi verificado, de modo geral, que o cimento no modo dual apresentou maiores valores de dureza do que no modo físico, exceto para as condições HL sem material para faceta e com Artglass e LED com HeraCeram. Quando se fixou o nível dual, foi observado que com o LED foram obtidos os maiores valores de dureza nas condições sem material e sob HeraCeram, comportamento não observado sob Artglass, em que os valores de dureza foram similares para os 3 aparelhos. Para HL o menor valor de dureza foi obtido sob HeraCeram e para LED, sob Artglass. Para PAC, os menores valores foram observados sob HeraCeram e na condição sem material. Quando se fixou o nível físico para ativação do cimento, com o LED foram obtidos os maiores valores de dureza na ativação direta e sob HeraCeram, seguido pela HL e PAC, respectivamente. Sob Artglass, os maiores valores de dureza foram obtidos com HL seguido pelo LED e PAC, respectivamente. Sob Artglass e HeraCeram, não foi possível determinar os valores de dureza do cimento fotoativado com PAC. A interposição de HeraCeram mostrou influenciar negativamente a ativação com HL. Para o LED esse comportamento foi verificado sob Artglass / Abstract: The increasing demand for esthetic restorations has increased the use of ceramics and composites in oral rehabilitation. The resin-based cement is the material of choice to fix these prosthetic restorations. This material can polymerize by chemical activation, physical activation or by a combination of chemical/ physical activation. In several clinical situations light curing must be performed indirectly through ceramics or composite. Sometimes, in cases in which esthetic is the major goal, light-cured cements are preferred because their longer color stability. However, the chemical activation can guarantee the polymerization of the cement. The present study aimed to evaluate the Knoop hardness of the resin-based cement Enforce, activated by chemical/ physical mode or by physical mode solely, light-cured directly or through 1.5mm of ceramics (HeraCeram) or composite (Artglass) using different light-curing devices. For light-curing the following activation times were used: conventional halogen light (XL2500) applied for 40s - HL; light emitting diodes (Ultrablue Is) for 40s - LED; and light emitted by xenon plasma arc (Apollo 95E) for 3s - PAC. Bovine incisors embedded in polystyrene resin had its buccal faces ground flat and submitted to the hybridization technique. On the hybridized dentin area a rubber mold was seated (1mm thickness and 5mm diameter), into which the manipulated cement was deposited. A disc of one of the prosthetic materials was seated over this set to proceed the light-curing. After storage for 24h at 37oC, the samples were sectioned and submitted to hardness measurements in 3 different depths: near to restorative material, near to dentin and in the center. The hardness (KHN) measurements were performed in a micro-hardness tester after 50gf load by 15s. Data were submitted to ANOVA and to Tukey¿s test, with a=0.05. In general, it was verified that dual cement presented higher hardness compared to physical mode, exception to HL in direct light curing and with Artglass and LED with HeraCeram. When the level dual was fixed, higher hardness was observed with LED in direct light curing and with HeraCeram, what was not observed with Artglass, in which similar hardness values were obtained with different devices. For HL, the lowest hardness was observed with HeraCeram and for LED, with Artglass. For PAC, lower hardness was verified in direct light curing and with HeraCeram. When the level physical mode for cement activation was fixed, the highest hardness was obtained with LED in direct light curing and with HeraCeram followed by HL and PAC, respectively. With Artglass, the highest hardness was observed with HL followed by LED and PAC, respectively. It was not possible to determine the hardness of physical activated cement light-cured with PAC through Artglass and HeraCeram. Light curing through HeraCeram showed to be deleterious to HL. For LED, this behavior was noted with Artglass / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
68

A comparison of bond strength between an orthodontic adhesive resin cured with halogen light or plasma arc light an in vitro and in vivo study /

Signorelli, Michael D. January 2003 (has links)
Thesis (M.S.)--West Virginia University, 2003. / Title from document title page. Document formatted into pages; contains viii, 107 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 66-71).
69

Development and use of a miniature ultrasonic pulser receiver

Nguyen, San Boi. January 2008 (has links)
The field of restorative dentistry and the problem of ultrasonic airframe corrosion in aerospace are introduced as motivation for the construction of a miniature ultrasonic pulser/receiver. / A broadly applicable ultrasonic pulser and receiver system is developed. Two pulsers, a 5V square and a 100V spike, and a 52dB amplifier with a 57MHz 6dB bandwidth were constructed as a result. These battery powered devices are tailored for compatibility with a custom built wireless data transmission system, also driven by the same voltage. It is demonstrated that the new pulser/receiver is comparable to the commercial system in performance in certain areas. / The new pulsers/receiver and a commercial one are used in this work. The data is acquired and analyzed using LabView and Matlab. It is shown that the ultrasonic technique can be used to follow the reaction in time as well as to gauge the cure of dental composites. The current work in ultrasonic airframe corrosion detection is furthered and the wireless system's functionality is affirmed.
70

Penetration of unfilled and composite resins into acid-etched human enamel a thesis submitted in partial fulfillment ... restorative dentistry ... /

Pahlavan, Ayoub. January 1975 (has links)
Thesis (M.S.)--University of Michigan, 1975.

Page generated in 0.0634 seconds