• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do sistema de acabamento e polimento na rugosidade superficial e formação in situ de biofilme dentário inicial em cerâmica feldspática micro-particulada

Brentel, Aline Scalone [UNESP] 10 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-10Bitstream added on 2014-06-13T18:35:09Z : No. of bitstreams: 1 brentel_as_me_sjc.pdf: 699454 bytes, checksum: be2fb21f3ef054302d8fc5241d84a0a5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi avaliar uma cerâmica feldspática micro-particulada quanto à rugosidade superficial, hidrofobicidade e formação in situ do biofilme dentário. Amostras padronizadas da cerâmica foram confeccionadas e divididas em 4 grupos conforme o sistema de acabamento e polimento: glaze (G1); glaze e broca diamantada (G2); glaze, broca diamantada e pontas de borracha (G3); glaze, broca diamantada, ponta de borracha e disco de feltro impregnado com pasta diamantada (G4). Rugosidade foi avaliada antes e após os procedimentos de acabamento e polimento estabelecidos para cada grupo. O ângulo de contato da água deionizada foi avaliado em goniômetro. Dez pacientes usaram dispositivo bucal com amostras dos diferentes grupos durante 8 h. Decorrido o período experimental, o biofilme (n=10) foi analisado em microscopia confocal laser ( biovolume e espessura média) e microscopia eletrônica de varredura (MEV) (n=5). A rugosidade superficial foi significativamente diferente nos 4 grupos, sendo a ordem crescente de rugosidade G1 < G4 < G3 < G2. Em relação ao ângulo de contato, G1 apresentou a maior hidrofobicidade, não havendo diferenças entre os demais grupos. G1 e G4 foram semelhantes e apresentaram os menores valores de espessura média e biovolume do biofilme. G2 e G3 apresentaram os maiores valores de espessura média e biovolume sendo similares. Correlação positiva foi verificada entre rugosidade superficial e formação de biofilme in situ. As observações em MEV indicaram cocos isolados e diplococos em G1 com pouco material acelular. Em G2, presença de maior número de bactérias aderidas às amostras foi verificada. Em G3 foi verificado material fibrilar com cocos e bastonetes curtos constituindo colônias na superfície. Em G4, as amostras foram recobertas por material granular com poucos cocos isolados aderindo à superfície. / This study assessed the effect of different systems of finishing and polishing in a ceramic micro-particulate feldspatic, with respect, the surface roughness, hydrophobicity, topography and morphology analysis using SEM and analysis of biofilms, with respect to its thickness and its average biovolume using MCVL. Specimens (5mmX2mm), were distributed into four groups (n = 10) as, finishing and polishing used: G1: glaze; G2 - drill diamantada (KG Sorensen); G3 - diamantada drill and polishing with rubber tip (KG Sorensen); G4 - diamantada drill and polishing with rubber tip followed by pulp diamantada with disc of felt. Rugosidade was evaluated in rugosímetro (Surftest SJ-301, Mitutoyo) before and after applying the glaze. The hydrophobicity was evaluated by a goniometer (Ramé-Hart - DROPimage, Advanced, USA) Ten patients used a device with the samples for 8h, then they were tested in MCVL. Topography and the morphology were evaluated in SEM. The roughness Ra (μm), biovolume and thickness of the biofilm and were analyzed using ANOVA and Tukey. There was no significant difference with respect to the amount of biovolume factor and the average thickness of biofilm between G2 and G3 and between G1 and G4. G1 and G4, were more hydrophobicity, with respect to G2, G3. There are correlated with roughness and formation of biofilms. There is the possibility of hydrophobicity is linked to lower bacterial adherence.
2

Desenvolvimento e avaliação da efetividade de duas pastas polidoras em padrão nanométrico empregadas a materiais restauradores estéticos: análise comparativa por perfilometria digital e microscopia de força atômica

Elossais, André Afif [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-28Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 elossais_aa_dr_arafo.pdf: 996142 bytes, checksum: 88037f1a3f60e9e1dfbc58af37913bed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Considerando a recente introdução de resinas nanoparticuladas no mercado odontológico, este trabalho teve o propósito de desenvolver duas pastas polidoras em padrão nanométrico e estudar os tratamentos superficiais e técnicas de polimento comumente empregadas para as diferentes resinas já disponíveis e também para esses novos produtos. Foram confeccionados 40 corpos-de-prova para cada resina composta: Vit-l-escence™ – microhíbrida (M1) e Filtek™ Z350 – nanoparticulada ou nanoaglomerada (M2). As amostras foram armazenadas por 24 horas em água destilada a 37_C + 1_C, para então serem submetidas ao tratamento superficial, onde a rugosidade média (Ra) foi analisada em quatro etapas consecutivas: Grupo Controle – T0 (Controle A – tira de poliéster Mylar™ e Controle B – Pincel Hot Spot™ Design); polimento com o sistema de discos abrasivos – T1 (Sof-Lex Pop On™); polimento com pastas abrasivas em padrão micrométrico – T2 (Diamond Polish Paste™ e Enamelize™) e polimento com pastas abrasivas nanométricas – T3 (Lummina-E Diamond e Lummina-E Alumina). Os resultados obtidos revelaram que, em todas as etapas observadas, as resinas compostas exibiram valores de rugosidade média muito satisfatória, sendo que a resina composta M1 alcançou os menores valores. Quando empregada a Tira de Poliéster Mylar™ como Grupo Controle (Controle A), os menores valores de rugosidade média foram inqüestionavelmente observados na etapa T0. Quando empregados os discos abrasivos Sof-Lex Pop On™ (etapa T1), a rugosidade média das amostras aumentou significativamente quando comparado à etapa T0 (Grupo Controle A – Tira de Poliéster Mylar™). Ao se eliminar a etapa T1 do Grupo Controle B (Pincel Hot Spot Design™), na etapa T2 os valores de rugosidade média diminuíram substancialmente, porém, continuaram superiores àqueles obtidos pelo Controle A e também pelo... / Considering the recent introduction of nanocluster resin-based materials in dentistry market, this work had the intention to develop two nanometricpatterned polish pastes and to also evaluate whether the polishing techniques commonly used, and which feature satisfactory results for the different resins already available, are appropriate for these new products. Fourty test specimens were fabricated for each composite resin: Vit-lescence ™ – micro-hybrid particles (M1) and Filtek™ Z350 – nanoparticled or nanocluster (M2). The samples were stored within distilled water at 37_C + 1_C by 24 hours and submitted to surface treatment, where the mean roughness was assessed in four consecutive phases: control – T0 (standardization with polyester matrix bands and Hot Spot Design™ brush); polishing with abrasive disc system – T1 (Sof-Lex Pop On™); polishing with micro-patterned polishing pastes – T2 (Diamond Polish Paste™ and Enamelize™) and polishing with nano-patterned polishing pastes – T3 (Lummina-E Diamond and Lummina-E Alumina). Obtained results showed that, in all the phases observed, the composite resins featured rather satisfactory mean roughness scores, where composite resin M1 reached the lowest scores. It was demonstrated that the lowest mean roughness scores were unquestionably observed in phase T0 for all the composite resins, where the test specimens’ standardization was performed with polyester matrix bands (control group). When the abrasive discs were used (phase T1), the samples mean roughness had a significant increase when compared to phase T0. When phase T1 was eliminated in Control Group B (Hot Spot Design™ brush), in the phase T2 mean roughness values had decreased substantially, however, they had continued higher compared to Control A and B. In phase T2 (polishing with micro-patterned pastes) mean roughness values also decreased compared to phase... (Complete abstract click electronic access below)
3

Avaliação da rugosidade superficial de restaurações estéticas e do esmalte adjacente após o uso de diferentes instrumentos rotatórios de acabamento e polimento

Silva, Regina Célia Santos Pinto [UNESP] 03 July 1997 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1997-07-03Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000036229.pdf: 3107646 bytes, checksum: d0806c4df33a9f0925861dab953b0da8 (MD5) / O propósito do presente trabalho foi avaliar in vitro a rugosidade superficial de dois materiais restauradores estéticos, resina composta TPH (Dentsply) e compósito poliácido modificado VariGlass (Dentsply) e também do esmalte adjacente a estas restaurações, após procedimentos de acabamento com ponta diamantada e brocas multilaminadas de oito e 12 lâminas e polimento com ponta verde de silicone, pasta diamantada e a associação das duas. Foram selecionados 114 dentes sendo que seis deles foram deixados intatos para se avaliar a rugosidade do esmalte sem nenhum tipo de tratamento e os demais receberam preparos cavitários no terço médio da face vestibular, sendo restaurados conforme instruções do fabricante. Os corpos de prova foram armazenados em água destilada, em estufa a 370, por 24 horas, após o que receberam acabamento e polimento. Após estes procedimentos os corpos de prova foram analisados num rugosímetro Perthometer S8P (Perthen, Mahr, Germany) e os dados obtidos foram analisados estatisticamente. De acordo com os resultados pudemos verificar que a resina composta apresenta menor rugosidade que o cimento de ionômero vítreo; que o esmalte adjacente às restaurações tomou-se mais liso que o esmalte íntegro: as brocas multilaminadas mostraram menores valores de rugosidade quando comparadas às pontas diamantadas, com diferença estatisticamente significante; nenhum dos procedimentos de acabamento e polimento empregados foi satisfatório para o cimento de ionômero vítreo, que apresentou os maiores valores de rugosidade média e são necessárias novas investigações sobre acabamento e polimento desses materiais, assim como pesquisas sobre o próprio material para que possamos vir a ter restaurações com melhor qualidade de superfície / The purpose of this in vitro study was to evaluate the surface texture of two aesthetic restorative materials: a composite resin TPH (Dentsply) and a polyacid-modified composite VariGlass (Dentsply). as well as the adjacent enamel to these restorations, after polishing and finishing procedures with diamond points, with eight and twelve blade trimming and finishing burs, with a green silicone tip, with a diamond polishing past and with an association of the last two procedures. We have selected 114 teeth, six of wich received neither polishing nor finishing procedures, with the purpose of evaluating the enamel roughness. The remaining teeth received cavity preparations on the buccal surfaces and were restored following the manufacture' s instructions. The specimens were kept for 24 hours in destiled water at 37° C and only then polishing and finishing procedures were performed. Profilometric analyses were carried out using a Perthometer S8P (Perthen, Mahr, Germany) and the collected data were statísticaly analysed. The results showed that the composite resin presented less surface roughness than the polyacid-modified composite, that the enamel adjacent to the restorations became smoother than the sound enamel; that the eight and twelve blade burs promoted surfaces less roughen than the diamond points, with statisticaly meaningful difference. None of the finishing and polishing procedures demonstrated to be satisfactory for the glass ionomer cement. Researches concerning the finishing and polishing of this material are necessary, as well as the material itself: so that better surface texture restorations could be obtained
4

Avaliação comparativa in vitro da rugosidade superficial de resinas compostas submetidas a diferentes técnicas de polimento

Elossais, André Afif [UNESP] 04 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-04Bitstream added on 2014-06-13T20:31:07Z : No. of bitstreams: 1 elossais_aa_me_arafo.pdf: 655660 bytes, checksum: 5f9cef1483df2a044b0c6daa7619e3ba (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com os avanços científicos aplicados à Odontologia moderna para a finalidade da melhoria em aspectos físicos e estéticos, a indústria Odontológica lança constantemente inúmeros produtos, sendo que nos últimos anos surgiram as resinas classificadas como nanoparticuladas, com o intuito de melhorar o resultado final das restaurações. Considerando a introdução dessas novas resinas em padrão nanométrico, este trabalho se propôs avaliar se as técnicas de polimento comumente empregadas e que apresentam resultados satisfatórios para as diferentes resinas já disponíveis no mercado Odontológico, também o são para esses novos produtos. Foram confeccionados 36 corpos-de-prova para cada resina composta: Renamel Microfill® - microparticulada (M1), Vitalescence - micro-híbrida (M2), Esthet-X - micro-matriz (M3) e Filtek Supreme - nanoparticulada ou nanoaglomerada (M4). As amostras foram armazenadas em água destilada a 37°C + 1°C, para então serem submetidas ao tratamento superficial, onde a rugosidade média foi analisada em três etapas consecutivas: controle - T0 (padronização com tiras de matriz de poliéster), polimento com os sistemas de discos abrasivos - T1 (Super Snap Rainbow® Technique, Flexidiscs e Sof-Lex Pop On) e polimento com pastas - T2 (Diamond Polish Paste e Enamelize). Os resultados obtidos revelaram que, em todas as etapas observadas, as resinas compostas exibiram valores de rugosidade média muito satisfatória, sendo que a resina composta M1 alcançou os menores valores, seguida por M2, M3 e M4. Ficou demonstrado neste estudo que, para todas as resinas compostas os menores valores de rugosidade média foram inquestionavelmente observados na etapa T0, onde ocorreu a padronização dos espécimes com tiras de matriz de poliéster (grupo controle). Quando empregados os discos abrasivos (etapa T1), a rugosidade média das amostras aumentou significativamente... . / Considering the scientific developments applied to modern Dentistry in order to improve both physical and esthetical aspects, dental industry constantly releases a number of products. In recent years resins qualified as nanoparticled have arisen aiming the improvement of the restorations final results. In regard to the introduction of these new nanometric-patterned resins, the present study objective was to evaluate whether the polishing techniques commonly used, and which feature satisfactory results for the different resins already available in the dental market, are appropriate for these new products. Thirty-six test specimens were fabricated for each composite resin: Renamel Microfill® - microparticles (M1), Vitalescence - micro-hybrid particles (M2), Esthet-X - micro-matrix (M3) and Filtek Supreme - nanoparticled or nanocluster (M4). The samples were stored within distilled water at 37°C + 1°C, and submitted to surface treatment, where the mean roughness was assessed in three consecutive phases: control - T0 (standardization with polyester matrix bands), polishing with abrasive disc systems - T1 (Super Snap Rainbow® Technique, Flexidiscs and Sof-Lex Pop On) and polishing with pastes - T2 (Diamond Polish Paste and Enamelize). The results obtained showed that, in all the phases observed, the composite resins featured rather satisfactory mean roughness scores, where composite resin M1 reached the lowest scores, followed by M2, M3 and M4. It was demonstrated in this study that the lowest mean roughness scores were unquestionably observed in phase T0 for all the composite resins, where the test specimens standardization was performed with polyester matrix bands (control group). When the abrasive discs were used (phase T1), the samples mean roughness had a significant increase when compared to phase T0. Among the abrasive discs tested, Flexidiscs disc system always showed... (Complete abstract, access undermentioned eletronic adress).
5

Rugosidade superficial do esmalte e de resinas compostas: avaliação de instrumentos de acabamento pelo microscópio de força atômica

Oliveira, Ana Carolina Botta Martins de [UNESP] 26 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-26Bitstream added on 2014-06-13T18:51:42Z : No. of bitstreams: 1 oliveira_acbm_me_arafo.pdf: 4311802 bytes, checksum: 1f571cd42db44ab09a36226da7dcd075 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de instrumentos de acabamento e técnicas de polimento sobre a rugosidade superficial de resinas compostas e comparar ao esmalte humano íntegro, através do Microscópio de Força Atômica (MFA). Superfícies planas de face vestibular de quatro incisivos centrais superiores humanos hígidos foram usadas para análise da rugosidade superficial do esmalte. Resinas compostas nanoparticulada (Filtek Supreme XT, 3M ESPE), microhíbrida (Point 4, Kerr Corp.), híbrida (tetric Ceram, Ivoclar Vivadent) e microparticulada (Durafill VS, Heraeus Külzer) foram avaliadas. Todas as amostras de resinas compostas foram confeccionadas sob uma tira de poliéster. Os procedimentos de acabamento superficial foram realizados com uma fresa carbide de 30 lâminas e uma ponta diamantada de 30 æm nas amostras de resinas compostas nanoparticulada e microhíbrida. Quatro técnicas de polimento (TO : Matriz de poliéster - controle: T1 : discos de óxido de alumínio; T2 : disco de feltro + pasta diamantada) foram testadas em todas as amostras de resinas compostas. Nrugosidade média superficial (Ra) foi avaliada pelo MFA no modo contato. Os dados obtidos foram submetidos ao Teste t de Student, á análise de variância e ao Teste de Tukey, ao nível de 5% de significância. A maior lisura superficial foi obtida com a matriz de poliéster para Filttek Supreme XT (Ra=23,63nm), Point 4 (Ra=12,84nm) e Tetric Ceram (Ra=15,20nm). Aresina Durafill VS foi menos rugosa com os discos de óxido de alumínio (Ra=43,05nm). A maior rugosidade superficial foi obtida com a ponta diamantada para Filek Supreme XT (Ra=510,55nm) e Point 4 (Ra=531,64nm), sem diferença estatisticamente significante entre elas. A rugosidade superficial do esmalte foi de 46,55 nm. Com base nestes resultados põde-se concluir que a rugosidade superficial aumentou significamente... / The aim of this study was to assess the effect of finishing instruments and of polishing techniques on surface roughness of composite resins and to compare to intact human enamel through Atomic Force Microscope (AFM). Flat buccal surface of four caries-free human maxillary central incisors were used for the roughness analysis of enamel. Nanofiller (Filtek Supreme XT, 3M ESPE), microhubrid (Point 4, Kerr Corp.), hybrid (tetric Ceram, Ivoclar Vivadent) and microfilled Durafill V.S., Heraeus Külzer) composite resins were evaluated. Mylar matrix strip was used as control group for both analyses. Finishing procedures were done with a 30-blade carbide bur and 30 æm finishing diamond ur for nanofiller and microhybrid resins. Four polishing techniques weretested (T0 : Mylar matrix - control; T1: aluminium oxide discs; T2: felt disc+ diamond paste; T3: aluminium oxide discs + felt disc + diamond paste in all composite resins. The mean roughness (Ra) was evaluaed under AFM on the contact mode. The obtained data was submitted to Studentþs t test, variance , variance analysis (ANOVA) and, Tukeyþs Test, at 5% level of significance. The smoothest surface was obtained with ylar matrix associated with Filtek Supreme XT (Ra=23,63nm), Point 4 (Ra=12,84nm) and Tetric ceram (Ra=15,20nm). Durafill VS showed the lowest roughness with aluminium oxide discs (Ra=43,05nm). The highest surface eoughness was obtained with diamond bur for Fittek Supreme XT (Ra=510,55nm) and point 4 (Ra=531,64nm), without significant difference between them. Surface roughness of enamel was of 46,55nm. Roughness increased significantly after fishing procedures. 30-blade carbide bur produced less roughness compared to extra fine diamond bur. Diamond paste also increased the roughness of composites. Aluminium oxide discs may be used as standard polishing technique for all composite resins, except for hybrid... (Complete abstract, click electronic access below)

Page generated in 0.0718 seconds