• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The use of "fluid-resins" for relining partial dentures a thesis submitted in partial fulfillment ... in denture prosthesis ... /

Cabrera-Diaz, Renato. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
2

The use of "fluid-resins" for relining partial dentures a thesis submitted in partial fulfillment ... in denture prosthesis ... /

Cabrera-Diaz, Renato. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971.
3

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese

Seó, Rosangela Seiko [UNESP] 28 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-07-28Bitstream added on 2014-06-13T20:45:48Z : No. of bitstreams: 1 seo_rs_dr_arafo.pdf: 1569094 bytes, checksum: 0536169530bfd87cba3e3e4bd106c1b7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection.
4

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas /

Reis, José Mauricio dos Santos Nunes. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Renata Cunha Matheus Rodrigues Garcia / Banca: Karin Hermana Neppelenbroek / Banca: João Neudenir Ariolli Filho / Banca: Eunice Teresinha Giampaolo / Resumo: Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below) / Doutor
5

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas

Reis, José Mauricio dos Santos Nunes [UNESP] 03 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-03Bitstream added on 2014-06-13T19:44:47Z : No. of bitstreams: 1 reis_jmsn_dr_arafo.pdf: 1310753 bytes, checksum: 17bd719b0c46c00b10cbd2db022db42a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... / This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below)
6

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese /

Seó, Rosangela Seiko. January 2006 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Banca: Rodrigues Nunes Rached / Resumo: O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / Abstract: This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection. / Doutor

Page generated in 0.4046 seconds