• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 437
  • 135
  • 21
  • 18
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 640
  • 365
  • 209
  • 194
  • 184
  • 163
  • 113
  • 104
  • 98
  • 96
  • 87
  • 85
  • 83
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
551

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Aguiar Junior, Fábio Afrânio de 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
552

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Glenda Lara Lopes Vasconcelos 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (μm) apresentou-se não normal. Foi utilizada estatística não-paramétrica (α=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (μg/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (α=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes™, Steradent™, Efferdent™, Polident for Partials™ and Corega Tabs™. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (α = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
553

Avaliação das variações de massa e rugosidade de superfície causadas pelos métodos mecânico (escovação) e combinado (escovação e imersão) de higiene de próteses totais / Evaluation of mass variation and surface roughness caused by the association of mechanical (brushing) and chemical (immersion) methods of denture cleanser

Danilo Balero Sorgini 30 January 2015 (has links)
O objetivo deste trabalho foi avaliar a variação de massa e a alteração da rugosidade de superfície, causadas pela associação dos métodos mecânico (escovação) e químico (imersão) de higiene de próteses totais. Foram utilizados 240 corpos de prova de acrílico Plexiglass (90 x 30 x 3 mm). O ensaio de escovação (método mecânico) foi realizado em máquina de escovação (Mavtec), em frequência de 356 rpm, curso da escova (Tek Macia) de 3,8 centímetros, peso da sapata de 200 gramas e tempo de 50 minutos (simulação de 01 ano de escovação). Como suspensões, foram utilizadas água destilada e 04 dentifrícios (02 convencionais: Sorriso e Colgate; e 02 específicos para próteses totais: Polident e Corega). Após a escovação, os corpos de prova foram imersos em água destilada, hipoclorito de sódio a 0,5%, solução de mamona a 10% e Corega Tabs por 121,6 horas (simulação de 01 ano de imersão, por 20 minutos diários - ciclo curto) e 2920 horas (simulação de 01 ano de imersão, por 8 horas ao dia - ciclo longo). Foram obtidos 20 grupos (n=12), combinando as 05 substâncias utilizadas na escovação às 4 soluções utilizadas nos ensaios de imersão. A variação de massa foi avaliada pelo método Gravimétrico indireto, sendo as pesagens realizadas em balança (Metler Toledo GMbH) antes dos procedimentos de higiene (M0), após a escovação (M1), após a imersão pelo ciclo curto (M2) e após a imersão pelo ciclo longo (M3). A alteração da rugosidade de superfície (&mu;m) foi avaliada por rugosímetro (Surtronic 25), por meio da obtenção de média de três leituras (4,0 mm de comprimento e valor de \"cut-off\" de 0,8 mm, a 0,5 mm/s) antes dos procedimentos de higiene (RS0), após a escovação (RS1), após a imersão pelo ciclo curto (RS2) e após a imersão pelo ciclo longo (RS3). Os dados provenientes do método mecânico foram submetidos ao teste não paramétrico Kruskal-Wallis, seguido pelo pós-teste de Dunn (p<0,01); os dados relativos à comparação dos diferentes métodos de higiene foram submetidos ao teste de regressão linear (p<0,01). Para o método mecânico, quanto à variação de massa, entre os dentifrícios, os maiores valores foram registrados para a escovação com Sorriso (-0,0111±0,0032), enquanto os menores, para a escovação com o Polident (-0,0069±0,0023). Para a alteração da rugosidade de superfície, os maiores valores foram obtidos para a escovação com Sorriso (2,2003±1,8932), enquanto os menores, para o Corega (0,9263±0,8621). Quanto à comparação dos métodos, para a variação de massa, quando o método combinado foi realizado com imersão em hipoclorito de sódio, houve perda de massa após ambos os ciclos, enquanto que, as imersões em água destilada, mamona e Corega Tabs, acarretaram um aumento de massa. Quanto à alteração de rugosidade de superfície, não houve diferença significativa entre métodos ou entre soluções utilizadas para imersão. Conclui-se que é importante a indicação de dentifrícios específicos para próteses totais, em virtude da menor magnitude dos efeitos adversos causados, e que, a incorporação de um método químico à escovação, não causa efeitos adversos clinicamente significantes ao substrato empregado / The aim of this study was to evaluate the mass variation and changes in surface roughness when mechanical and chemical methods of denture cleanser were associated. Two hundred and forty Plexiglass specimens (90x30x3 mm) were used. The brushing test was carried out using a toothbrushing machine (Mavtec), with a frequency of 356 rpm, course covered by brush corresponds to 3.8 cm, the load was standardized at 200 g, and length of 50 minutes (01 year of brushing). As suspensions, were utilized distilled water and 04 dentifrices (02 conventional: Sorriso and Colgate; and 02 indicated for denture cleanser: Polident and Corega). After brushing, the specimens were immersed in sodium hypochlorite (NaClO) 0,5%, Ricinus communis 10% solution and Corega Tabs for 121,6 hours (01 year of immersion, 20 minutes daily - short cycle) and 2920 hours (01 year of immersion, 8 hours daily - long cycle). Twenty groups were obtained, associating the 05 brushing solutions with the four immersion products. The specimens were weighed before the tests (M0), after the brushing test (M1), after short cycle immersion test (M2) and after the long cycle immersion test (M3) in a precision balance (Metler Toledo GMbH). The surface roughness (&mu;m) was evaluated by a rughosimeter (Surftest SJ-201P) before the tests (R0), after the brushing test (R1), after short cycle immersion test (R2) and after the long cycle immersion test (R3). The mechanical method results was submitted to Kruskal-Wallis non-parametric test, and Dunn\'s test (p<0,01); For the hygiene methods, the linear regression analysis (p<0,01) was used. For the mechanical method, the dentifrice that caused the greatest mass variation was Sorriso (-0,0111±0,0032), while the lowest variation was caused by Polident (-0,0069±0,0023). For the surface roughness, the greatest values were obtained for Sorriso (2,2003±1,8932), and the lowest, for Corega (0,9263±0,8621). For the comparison of the methods, for the mass variation, when the combined method was performed with immersion in sodium hypochlorite, there was mass loss after both combined cycles. Immersions in water, Ricinus communis and Corega Tabs, resulted in mass increase. For the surface roughness changes, there was no significant difference between methods or solutions used for immersion tests. It was concluded that it is important to indicate specific dentifrices for complete dentures, due to the small magnitude of the adverse effects, and that the incorporation of a chemical method to the brushing does not cause clinically significant adverse effects
554

Eficácia da escovação associada à irrigação oral na manutenção dos tecidos peri-implantares e overdentures estudo clínico randomizado / Effectiveness of brushing associated with oral irrigation in maintenance of peri-implant tissues and overdentures randomized clinical trial

Marcela Moreira Salles 27 January 2017 (has links)
A manutenção das próteses implantossuportadas e da saúde dos tecidos peri-implantares está diretamente relacionada ao sucesso do tratamento reabilitador. O objetivo deste trabalho foi avaliar, por meio de estudo clínico randomizado, a eficácia de um método experimental (escovação associada à irrigação oral), na manutenção dos tecidos peri-implantares e overdentures. Foram analisadas capacidade de remoção de biofilme e manutenção da saúde dos tecidos orais, ação antimicrobiana e satisfação do paciente. Foram selecionados 38 pacientes usuários de prótese total superior convencional e overdenture inferior, retida por implantes ou mini-implantes e sistema de encaixe tipo o\'ring. Os pacientes utilizaram os seguintes métodos: ES (Controle): método mecânico da escovação - escova específica para próteses totais, escova dental de cerdas macias e dentifrício e WP (Experimental): associação da escovação com a irrigação oral (Waterpik). Os pacientes foram orientados a higienizar suas próteses e tecidos peri-implantares, por meio do método da escovação, por 2 minutos, 3 vezes ao dia, sendo que no método experimental, os pacientes utilizaram a irrigação oral, uma vez ao dia, após a escovação, direcionando o jato de água à margem gengival e região dos componentes protéticos das overdentures. Todos os pacientes utilizaram os dois métodos de higiene, em uma sequência aleatória, por um período de 14 dias, com um período intercalado de 7 dias de wash out. As avaliações foram realizadas antes (baseline) e após a utilização de cada método. A capacidade de remoção de biofilme e a manutenção da saúde oral dos tecidos foram avaliadas por meio do Índice de Placa Modificado (IP), Índice Gengival (IG), Profundidade de Sondagem (PS) e Índice de Sangramento à Sondagem (SS). Para a análise da ação antimicrobiana, o biofilme subgengival foi coletado por meio de cones de papel e biofilme presente nos componentes das overdentures por meio de microbrush, e as amostras coletadas foram processadas pela técnica de hibridização DNA Checkerboard (39 espécies microbianas avaliadas). Os pacientes responderam a um questionário específico por meio de Escala Visual Analógica (EVA) de 100,0 mm, após o uso de cada método. Os dados relacionados aos parâmetros clínicos e à ação antimicrobiana foram analisados por meio do teste de Friedman (&alpha;=0,05), seguido de comparações realizadas por meio do teste de Wilcoxon; as comparações entre implantes convencionais e mini-implantes foram realizadas por meio do teste de Mann-Whitney (&alpha;=0,05). A análise das respostas ao questionário de satisfação foi realizada por meio do teste de Wilcoxon (&alpha;=0,05). Os resultados mostraram que, quanto aos parâmetros clínicos, houve diferença estatisticamente significante entre os valores obtidos no baseline e os valores após os métodos avaliados (p<0,001); entre os métodos ES e WP, não houve diferença significante (IP, IG e PS: p=1,000; SS: p=0,828); houve diferença estatisticamente significante entre os diferentes tipos de implantes apenas do IP após ES (p<0,05). Houve diferença estatisticamente significante entre os métodos (p<0,05), quando comparados os valores da quantidade total de células microbianas presentes no biofilme subgengival, sendo WP mais efetivo que ES (p<0,05), porém não houve diferença entre baseline e WP (p>0,05); considerando os micro-organismos avaliados, WP promoveu redução mais efetiva que ES apenas da espécie C. rectus (p=0,001). A quantidade total de células microbianas presentes nos componentes das overdentures nas avaliações foi semelhante (p=0,607) e a microbiota identificada apresentou-se qualitativamente semelhante após cada um dos métodos. Não houve diferença estatisticamente significante entre os diferentes tipos de implantes quanto ao total de células microbianas presentes no sulco peri-implantar e nos componentes das overdentures, identificadas em cada uma das avaliações (p>0,05). As médias das respostas ao questionário de satisfação após ambos os métodos foram altas (acima de 80,0 mm) para todas as questões, porém não houve diferença estatisticamente significante entre as respostas dadas após o uso de ES e WP (p>0,05). Concluiu-se que o método experimental foi eficaz na redução dos parâmetros clínicos avaliados; apresentou ação antimicrobiana mais efetiva na redução da quantidade total de micro-organismos presentes no biofilme subgengival; porém, não apresentou ação antimicrobiana frente aos micro-organismos presentes nos componentes protéticos das overdentures; e proporcionou alto nível de satisfação do paciente. / The maintenance of implant-supported prostheses and peri-implant health is directly related to the success of rehabilitation treatment. The aim of this study was to evaluate, through randomized clinical trial, the efficacy of an experimental method (brushing associated with oral irrigation) in the maintenance of the peri-implant tissues and overdentures. Biofilm removal capacity and oral tissues health maintenance, antimicrobial action and patient satisfaction were analyzed. Thirty-eight patients, users of conventional maxillary complete denture and mandibular overdenture retained by implants or mini-implants and o\'ring-retained system, were selected. The patients utilized the following methods: MB (Control): mechanical brushing method specific brush for dentures, soft bristle toothbrush and dentifrice, and WP (Experimental): association of mechanical brushing with oral irrigation (Waterpik). Patients were instructed to clean their dentures and peri-implant tissues, by means of brushing method for 2 minutes, 3 times a day, and in the experimental group, patients used the oral irrigation, once a day, after brushing, directing the water jet to the gingival margin and the region of the prosthetic components of the overdentures. All patients used both hygiene methods in a random sequence for a period of 14 days, with a 7-day wash-out interposed period. The evaluations were performed before (baseline) and after using each method. Biofilm removal capacity and oral tissues health maintenance were evaluated through Modified Plaque Index (PI), Gingival Index (GI), Probing Depth (PD), and Bleeding on Probing Index (BP). For the antimicrobial action analysis, the subgingival biofilm was collected by means of sterile paper cones and the biofilm present on the overdentures components by microbrush, and the collected samples were processed by the Checkerboard DNA hybridization technique (39 microbial species evaluated). Patients answered to a specific questionnaire using the Visual Analogue Scale (VAS) of 100.0 mm, after application of each method. The data related to clinical parameters and antimicrobial activity were analyzed using the Friedman test (&alpha;=0.05), followed by comparisons using the Wilcoxon test; comparisons between conventional implants and mini-implants were performed using the Mann-Whitney test (&alpha;=0.05). The analysis of the satisfaction questionnaire responses was performed using the Wilcoxon test (&alpha;=0.05). The results showed that, regarding clinical parameters, there was a statistically significant difference between the values obtained at baseline and the values after the evaluated methods (p<0.001); between the MB and WP methods there was no significant difference (PI, GI and PD: p=1.000; BP: p=0.828); there was a statistically significant difference between the different types of implants only of PI after MB (p<0.05). There was a statistically significant difference between the methods (p<0.05) when comparing the values of the total amount of microbial cells in the subgingival biofilm, WP being more effective than MB (p<0.05), but there was no difference between baseline and WP (p>0.05); considering the evaluated microorganisms, WP promoted a more effective reduction than MB only of the C. rectus species (p=0.001). The total amount of microbial cells present in the components of overdentures in the evaluations was similar (p=0.607) and the identified microbiota appeared qualitatively similar after each method. There was no statistically significant difference between the different types of implants for the total microbial cells in the peri-implant sulcus and in the overdentures components identified in each of the evaluations (p>0.05). The means of the satisfaction questionnaire responses after both methods were high (above 80.0 mm) for all the questions, but there was no statistically significant difference between the answers given after the use of ES and WP (p>0.05). It was concluded that the experimental method was effective in reducing the clinical parameters evaluated; presented more effective antimicrobial action in reducing the total amount of microorganisms present in the subgingival biofilm; however, showed no antimicrobial action against microorganisms present in the prosthetic components of the overdentures; and provided high level of patient satisfaction.
555

Avaliação biomecânica de prótese parcial fixa com cantilever sobre implantes em região posterior da mandíbula: estudo comparativo in vitro / Biomechanical evaluation of implant-supported cantilever fixed partial denture in posterior region of the mandible: in vitro comparative study

Raniel Fernandes Peixoto 28 June 2017 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, uma alternativa às cirurgias de enxerto ósseo, pouco empregada e estudada, é a utilização de prótese parcial fixa (PPF) com cantilever distal. Pensando no material de infraestrutura que garanta resistência adequada para suportar as forças mastigatórias em longo prazo, aliado ao desenvolvimento da zircônia (Zr) e da tecnologia CAD/CAM, o objetivo deste estudo foi avaliar o desajuste vertical, perda de torque, resistência à fratura do cantilever e distribuição de tensões em PPFs parafusadas sobre implantes do tipo cone morse, confeccionadas em diferentes materiais de infraestrutura (Co-Cr [Fundição Convencional] e Co-Cr e Zr [CAD/CAM]) e posicionadas na área correspondente à região posterior da mandíbula. Foram confeccionadas 40 PPFs com cantilever distal e distribuídas em 5 grupos (n=8), de acordo com o material da infraestrutura: 1 Co-Cr (Fundição convencional soldagem a laser); 2 Co-Cr (Fundição convencional soldagem TIG); 3 Co-Cr (Fundição convencional monobloco); 4 Co-Cr (CAD/CAM) e 5 Zr (CAD/CAM). A análise do desajuste vertical foi realizada em 4 momentos distintos, com auxílio de estereomicroscopia (aumento de 50×) e usando o método de Sheffiled: T0 Infraestrutura no modelo mestre; T1 Infraestrutura no modelo de poliuretano, antes da aplicação do revestimento cerâmico; T2 PPF após aplicação do revestimento cerâmico e antes da ciclagem termomecânica e T3 PPF após da ciclagem termomecânica. A avaliação do afrouxamento de parafusos foi realizada antes (T2) e após (T3) a ciclagem termomecânica e foi obtida com o auxílio de um torquímetro digital com precisão de 0,1 N.cm. Para a realização da ciclagem termomecânica as PPFs foram posicionadas na máquina de ensaio e uma carga de 120 N foi aplicada sobre elas, buscando simular 14 meses de utilização (1.200.000 ciclos). A resistência máxima à fratura do cantilever foi determinada por meio do ensaio de flexão e, para isso, uma carga perpendicular ao longo eixo da peça protética foi aplicada, com uma velocidade de aproximação de 0,5 mm/min. Uma nova PPF para cada grupo foi confeccionada para ser utilizada na avaliação da distribuição de tensões quando elas foram submetidas a carregamento puntiforme no cantilever e oclusal distribuído (150 N), por meio de análise fotoelástica. Em geral, PPFs com infraestruturas em monobloco (G3) apresentaram maiores desajustes verticais, especialmente no elemento solto da segunda e terceira condição experimental e foram associados com maior concentração de tensões, tanto no carregamento puntiforme (360,07 kPa) quanto oclusal distruído (302,46 kPa). Por outro lado, infraestruturas obtidas por meio do sistema CAD/CAM mostraram os menores desajustes verticais, se assemelhando estatisticamente (p>0,05), em vários momentos, com infraestruturas soldadas e melhores distribuições de tensões, atingindo valores inferiores a 280 kPa no carregamento puntiforme e a 200 kPa no oclusal distribuído. A moldagem de transferência (T0 &rarr; T1) e a ciclagem termomecânica (T2 &rarr; T3) pouco influenciaram no desajuste vertical dos grupos. Já o processo de aplicação do revestimento cerâmico (T1 &rarr; T2) e o seu efeito cumulativo com a ciclagem termomecânica (T1 &rarr; &rarr; T3) foram responsáveis por alterações consideráveis no desajuste vertical dos grupos, sobretudo naqueles fundidos convencionalmente (G1, G2 e G3). A ciclagem termomecânica teve um efeito considerável no percentual de perda de torque intragrupo (pMolar=0,039; pPré-molar=0,044), embora comparações entre os diferentes grupos não tenham demonstrado significância estatística (pMolar=0,116; pPré-molar=0,334). PPFs com infraestrutura metálica (>410,83±72,26 N) apresentaram resistência à fratura consideravelmente maior (p<0,05) do que a zirconia (277,47±39,10 N) e os primeiros sinais de fratura do revestimento cerâmico foram observados em torno de 900 N. Dentro das limitações deste estudo, PPFs com infraestruturas confeccionadas por meio do sistema CAD/CAM foram associadas com melhor adaptação cervical e distribuição de tensões, embora a secção das infraestruturas seguida de soldagem pode também ser uma alternativa viável, com base na proximidade dos valores de desajustes verticais e distribuição de tensão. Adicionalmente, PPFs com infraestruturas em zircônia podem ser usadas com certo grau de segurança, tendo em vista a boa adaptação marginal e distribuição de tensões, bem como altos valores de resistência à fratura constatados. / In cases of severe vertical bone loss, especially in posterior region of the mandible, an alternative to bone graft surgery, little used and studied, is the use of implant-supported cantilever fixed partial denture (FPD). Thinking about the framework material that ensures adequate strength to resist the masticatory loads in long term, together with the development of zirconia (Zr) and of CAD/CAM technology, the aim of this study is to evaluate the vertical misfit, torque loss and fracture resistance of cantilever and stress distribution in FPDs screwretained on Morse taper implants, fabricated with different framework materials (Co-Cr [Conventional Casting] and Co-Cr and Zr [CAD/CAM]) and positioned on the posterior region of the mandible. Forty FPDs with distal cantilever were fabricated and distributed into 5 groups (n=8), according to framework material: 1 Co-Cr (Conventional casting laser welding); 2 Co-Cr (Conventional casting TIG welding); 3 Co-Cr (Conventional casting one-piece); 4 Co-Cr (CAD/CAM) and 5 Zr (CAD/CAM). Analysis of vertical misfit was performed in 4 different moments, using stereomicroscopy (50× magnification) and the Sheffield method: T0 Framework on master model; T1 Framework on polyurethane model, before the ceramic veneering application; T2 FPD after application of the ceramic veneering and before the thermomechanical cycling and T3 FPD after thermomechanical cycling. Evaluation of screw loosening was performed before (T2) and after (T3) thermomechanical cycling and was obtained by a digital torque wrench with an accuracy of 0.1 N.cm. To perform the thermomechanical cycling, FPDs were positioned in the testing machine, and a 120 N load was applied on them, seeking to simulate 14 months of use (1,200,000 cycles). Fracture maximum resistance of the cantilever was determined by the flexural test and, therefore, a perpendicular force on the cantilever was applied at a crosshead speed of 0.5 mm/min. A new FDP for each group was fabricated to be used in the evaluation of the stress distribution, when they were submitted to punctiform on the cantilever and oclusal distributed loads (150 N), by the photoelastic analysis. In general, FPDs with one-piece frameworks (G3) presented higher vertical misfits, especially in the element not tightened of the second and third experimental conditions, and were associated with higher stress concentration in both the punctiform (360.07 kPa) and oclusal distributed (302.46 kPa) loads. On the other hand, the frameworks obtained by the CAD/CAM system showed the smaller vertical misfits, being statistically similar (p>0.05) to welded frameworks at various times, and better stress distributions, reaching values less than 280 kPa in the punctiform load and 200 kPa in the occlusal distributed load. Transfer impression (T0 &rarr; T1) and thermomechanical cycling (T2 &rarr; T3) had little effect on vertical misfit of the groups. The application process of the ceramic veneering (T1 &rarr; T2) and its cumulative effect with thermomechanical cycling (T1 &rarr;T3) were responsible for considerable changes in vertical misfit of the group, especially in those conventionally cast (G1, G2 and G3). A thermomechanical cycling had considerable effect in the percentage of intragroup torque loss (pMolar=0.039; pPré-molar=0.044), although comparisons between the different groups did not show statistical significance (pMolar=0.116; pPrémolar= 0.334). FPDs with metal frameworks (>410.83±72.26 N) showed considerably higher fracture resistance (p<0.05) than zirconia (277.47±39.10 N) and the first signs of fracture of the ceramic veneering were observed around 900 N. Within the limitations of this study, FPDs with frameworks fabricated using the CAD/CAM system were associated with better cervical adaptation and stress distribution, although the section of the frameworks followed by welding may also be a viable alternative, based on the proximity of the values of vertical misfits and stress distribution. Additionally, FPDs with zirconia frameworks can be used with some degree of security, considering the good marginal adaptation and stress distribution, as well as high values of fracture resistance verified.
556

Efeitos do uso de próteses múltiplas implantossuportadas, unidas e isoladas, nas tensões geradas em áreas posteriores da mandíbula / Load transfer characteristics in the posterior region of the mandible of implant supported, splinted and non-splinted restorations

Tiossi, Rodrigo 21 December 2010 (has links)
O comportamento biomecânico de próteses implantossuportadas foi analisado por fotoelasticidade e por correlação de imagens digitais (CID). Este trabalho estudou o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes, com coroas isoladas ou unidas, simulando a reabilitação de área posterior mandibular, com e sem a presença de elemento dental distal aos implantes. Devido às dificuldades em produzir estruturas múltiplas com assentamento passivo, alguns autores sugerem que implantes adjacentes sejam restaurados por próteses unitárias, minimizando os efeitos das tensões transferidas aos implantes. A análise fotoelástica é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. A análise por correlação de imagens digitais produz o mapeamento completo das tensões geradas na superfície do modelo analisado, possibilitando análises precisas. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. O material de recobrimento estético empregado na restauração protética também foi analisado (cerâmica e resina). O modelo de estudo foi composto por um pré-molar em resina, dois implantes (Titamax GT - 4,0 x 11,0 mm - Neodent) substituindo o 2º pré-molar e o 1º molar, e um 2º molar em resina. Outro modelo foi produzido sem a presença do 2º molar. Os grupos analisados foram: UC - coroas unidas e recobertas por cerâmica; IC - coroas isoladas e recobertas por cerâmica; UR - coroas unidas e recobertas por resina; IR - coroas isoladas e recobertas por resina. O efeito do torque na fixação das estruturas foi avaliado por meio de análise fotoelástica. Análise fotoelástica qualitativa e quantitativa foi realizada após a aplicação de carga vertical puntiforme (50 N) na superfície oclusal da coroa substituindo o 1º molar. A análise por correlação de imagens também foi feita qualitativa e quantitativamente, com a carga aplicada na mesma posição que para a análise fotoelástica, mas com maior intensidade (250 N). Tensões na direção horizontal (&epsilon;xx) e de cisalhamento (&epsilon;xy) foram analisadas e comparadas pelo método CID. Os dois métodos para análise de tensões aplicados neste estudo foram satisfatórios e adequados para as comparações necessárias ao trabalho proposto. De acordo com os resultados obtidos, pode-se concluir que a esplintagem de coroas sobre múltiplos implantes adjacentes promoveu melhor distribuição de tensões em torno dos implantes e pelas estruturas de suporte, principalmente quando o contato proximal distal esteve ausente. As tensões totais no modelo não foram influenciadas pela presença do 2º molar, mas este dente participou da distribuição de tensões entre as estruturas. O material de recobrimento das coroas não foi significativo para as tensões transferidas ao modelo fotoelástico e para as tensões compressivas (&epsilon;xx). As tensões de cisalhamento (&epsilon;xy) foram influenciadas diretamente pela presença do 2º molar inferior e, com sua ausência, um material de recobrimento com baixo módulo de elasticidade (resina) foi significativo para minimizar estas tensões. / A photoelastic stress analysis and a digital image correlation (DIC) method were used to analyze the biomechanical behavior of implant supported prosthesis. This study compared the biomechanical behavior of screwed, splinted and non-splinted, implant supported fixed partial dentures, simulating the rehabilitation of a mandibular posterior region, with and without the presence of a second molar proximal contact. Since complete passivity is difficult to achieve when splinted restorations supported by multiple implants are used, some authors suggest individually restoring adjacent implants to allow for a passive fit in the resulting restorations, thus reducing the strains transferred to the implants. Photoelasticity is an experimental technique for stress analysis and has been constantly used due its simplicity, reliable results and correlation with clinical findings. The digital image correlation method is capable of providing a full-field surface strain measurement, allowing for an accurate analysis. The ideal restoration of a partially edentulous space remains controversial as to the best prosthetic design for a partial rehabilitation with multiple implants in order to minimize the strains transferred to the bone-implant interface. The influence of the veneering materials was also compared (porcelain and resin). An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants (Titamax GT - 4.0 x 11.0 mm - Neodent) replacing the second premolar and first molar. Another model was made without the presence of the second molar. Groups were: UC - porcelain-veneered splinted crowns; IC - porcelain-veneered non-splinted crowns; UR - resin-veneered splinted crowns; IR - resin-veneered non-splinted crowns. Strains transferred to the photoelastic model were analyzed after tightening the prosthetic screws. Qualitative and quantitative photoelastic stress analysis was performed after the application of a vertical load (50 N) on the occlusal surface of the crown replacing the first molar. The image correlation analysis was also performed qualitatively and quantitatively, with the load applied in the same position as for the photoelastic analysis, although with greater intensity (250 N). Strains in the horizontal direction (&epsilon;xx) and shear strains (&epsilon;xy) were analyzed and compared with the DIC method. Both methods for strain analysis used in this study performed satisfactory and are adequate for the comparisons proposed in this work. According to the results found, it can be concluded that splinting multiple adjacent implant supported crowns provided a better strain distribution around the implants and the supporting structures, especially when the distal proximal contact was absent. The total strains in the model were not influenced by the presence of a distal proximal contact, but the presence of the second molar optimized the strain distribution between the structures. The crowns veneering material was not significant for the strains transferred to the photoelastic model and for compressive strains (&epsilon;xx). Shear strains (&epsilon;xy) were influenced by the presence of the second molar, and when it was absent, the use of a veneering material with low elasticity modulus (resin) significantly reduced these tensions.
557

VALIDAÇÃO DE MODELO DE INDUÇÃO DE CANDIDOSE BUCAL E AVALIAÇÃO DA TOXICIDADE SISTÊMICA AGUDA À CLOREXIDINA EM RATOS WISTAR

Moraes, Gustavo Simão 02 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-11-04T18:48:07Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Gustavo Moraes.pdf: 5377838 bytes, checksum: 3d28c8b25b98063e3bc2c7a4a8d3efb4 (MD5) / Made available in DSpace on 2018-11-04T18:48:07Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Gustavo Moraes.pdf: 5377838 bytes, checksum: 3d28c8b25b98063e3bc2c7a4a8d3efb4 (MD5) Previous issue date: 2018-02-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objetivo: Esta Dissertação foi composta por dois estudos. O primeiro avaliou métodos de esterilização de dispositivos palatais acrílicos para uso animal, bem como realizou a contaminação dos mesmos com Candida albicans. Ademais, verificou-se a duração da candidose bucal induzida por diferentes protocolos em ratos Wistar imunocompetentes e a efetividade da indução da estomatite protética em ratos imunocompetentes sob antibioticoterapia. O segundo avaliou parâmetros histológicos e bioquímicos como marcadores da toxicidade aguda hepática, renal, pulmonar e gástrica causada pela administração via gavage de doses tóxicas de clorexidina (Clx) nesses animais. Material e métodos: No Estudo I, dispositivos acrílicos foram confeccionados a partir de moldagens dos palatos dos animais utilizando moldeiras individuais e poliéter. Verificou-se a esterilização dos dispositivos (n=5) por meio do uso de micro-ondas (MO), luz ultravioleta (UV), ultrassom (US) ou nenhum método (CN), a partir de análises da viabilidade das colônias e em espectrofotômetro. Então, realizou-se a contaminação dos aparatos com um biofilme de C. albicans, a qual foi confirmada por meio de contagem de Unidades Formadoras de Colônia (UFC)/mL (n=6) e microscopia confocal a laser (n=5). Posteriormente, 20 animais foram divididos em cinco grupos (n=4): Cn=nenhum protocolo; Di=cimentação de dispositivo estéril; In=inoculação de suspensão de C. albicans no palato, sem a utilização de dispositivos; Dc=cimentação de dispositivo contaminado com C. albicans; In+Dc=junção dos grupos In e Dc. Os ratos foram monitorados durante uma semana para verificar a presença de sinais clínicos de candidose bucal por meio de fotografias dos palatos e línguas. Foi realizada a contagem de UFC/mL a partir de coletas feitas nos palatos utilizando swabs. Ao final dos sete dias, realizou-se a eutanásia e os palatos e línguas foram removidos para análise histopatológica. Finalmente, outros animais submetidos aos grupos Cn (n=2), Di (n=6) ou In+Dc (n=6) receberam tetraciclina na água de beber 7 dias antes de serem submetidos aos protocolos. Após o período de instalação da infecção (4 dias utilizando os dispositivos), as mesmas análises foram realizadas. No Estudo II, dois grupos foram avaliados (n=9): CN=administração de 1,5 mL de água destilada (veículo) via gavage ou Clx=1,5 g/Kg de Clx diluída no veículo. Após 24 h, os animais tiveram seu sangue coletado e órgãos removidos. No plasma, foram analisados os níveis de ureia, creatinina e ácido úrico (para análise do funcionamento renal), transaminase glutâmico-oxalacética (TGO), transaminase glutâmico-pirúvica (TGP) e fosfatase alcalina (FA) (para análise do funcionamento hepático), glicemia e lactato desidrogenase. Os órgãos foram avaliados por meio de análise histopatológica. Resultados: No Estudo I, o MO foi o único método que esterilizou os dispositivos (p<0,05; ANOVA 1-fator/Tukey HSD) e o protocolo de contaminação foi considerado adequado, com formação de biofilme composto por hifas e leveduras viáveis (1,2 x 106 UFC/mL). Não foram observadas alterações clínicas nos palatos dos animais. Foram observadas regiões despapiladas nas 11 línguas dos animais dos grupos In, Dc e In+Dc em até quatro dias após a indução da infecção. A recuperação de C. albicans a partir das coletas foi considerada baixa e os maiores valores foram obtidos no grupo In+Dc. Histologicamente, os tecidos apresentaram-se sem alterações epiteliais e no conjuntivo. Estando os animais sob antibioticoterapia, o valor recuperado de C. albicans foi 10 vezes superior para o grupo In+Dc após a instalação da infecção (1,3 x 104 UFC/mL). Foram observados eritema puntiforme e edema tecidual no palato e despapilação na língua desses animais. Histologicamente, foram observados microabscessos e infiltrado inflamatório no palato, além de invasão fúngica no epitélio das línguas. No Estudo II, a Clx provocou perda de peso (p=0,001) e redução no consumo de ração (p=0,008; ANOVA 2-fatores de medidas repetidas/Tukey HSD) e aumento nos níveis de TGO (p=0,026) e TGP (p=0,009) e redução nos níveis de FA (p=0,020; teste T nãopareado). Histologicamente, foram encontradas maiores alterações hepáticas (p=0,009; teste Qui-quadrado) para os animais do grupo CN e maiores alterações gástricas (p=0,05), para o grupo Clx, os quais apresentaram danos moderados (escore 3). Conclusão: No Estudo I, o método MO esterilizou os dispositivos; biofilme de C. albicans foi formado sobre os mesmos e a estomatite protética em animais sob antibioticoterapia foi evidenciada macroscopicamente, microscopicamente e histologicamente. No estudo II, a Clx administrada por gavage causou hepatotoxicidade e danos gástricos nos animais. / Purpose: This Dissertation was composed by two studies. The first study evaluated sterilization methods of acrylic palatal devices for animal use, as well as performed their contamination with Candida albicans. In addition, the duration of oral candidosis induced by different protocols in immunocompetent Wistar rats and the effectiveness of the induction of denture stomatitis in immunocompetent Wistar rats under antibiotic therapy was analyzed. The second one evaluated the effectiveness of histological and biochemical parameters as markers of acute hepatic, renal, pulmonary, and gastric toxicity caused by gavage administration of toxic doses of chlorhexidine (Chx) in Wistar rats. Material and methods: For the first study, acrylic devices were made from impressions of the animals’ palate with individual trays and polyether. Sterilization of the devices (n=5) was verified after submission to microwave (MW), ultraviolet light (UV), ultrasonic bath (US), or none method (NC), and assessed by colony viability and spectrophotometric analyses. Then, devices’ contamination with C. albicans was performed and confirmed by counting Colony Forming Units (CFU)/mL (n=6) and by laser confocal microscopy (n=5). Subsequently, 20 animals were divided into five groups (n=4): Nc=none protocol; Id=cementation of a sterile intraoral device; In=inoculation of a C. albicans suspension on the palate, without wearing a device; Cd=cementation of a device contamined by C. albicans; In+Cd=junction of In and Cd groups. The rats were monitored for one week to verify the presence of clinical signs of oral candidosis by taking photographs of their palates and tongues. CFU/mL counts were determined from the collected material of their palates using swabs. After one week, euthanasia was performed and the palates and tongues were removed for histopathological analysis. Finally, other animals of Nc (n=2), Id (n=6), or In+Cd groups (n=6) received tetracycline in the drinking water 7 days before being submitted to the protocols. After the disease installation period (four days using the devices), the same analyzes were performed. For the second study, two groups were evaluated (n=9): NC=administration of 1.5 mL of distilled water (vehicle) via gavage or Chx=1.5 g/Kg of Chx diluted in the vehicle. After 24 h, the animals had their blood collected and organs removed. In the plasma, the levels of urea, creatinine and uric acid (for kidney assessment), glutamicoxaloacetic transaminase (GOT), glutamic-pyruvic transaminase (GPT), alkaline phosphatase (AP) (for liver assessment), glycemia and lactate dehydrogenase were analyzed. The organs were evaluated by histopathological analysis. Results: In the first study, MW was the only method capable of sterilizing the devices (p<0.05; ANOVA 1-way/Tukey HSD), and the protocol used for contamination was considered satisfactory, developing a biofilm composed by viable hyphae and yeasts (1.2 x 106 CFU/mL). No clinical changes were observed in the palates of the animals. Areas of localized papillary atrophy were observed on the tongue dorsum of animals from In, Cd, and In+Cd groups until four days after the infection installation. The recovery of C. albicans was considered low and the highest values were obtained from the In+Cd group. Histologically, no alterations were observed. With the animals under antibiotic 13 therapy, the recovered values of C. albicans were 10 times higher for the In+Cd group after the infection installation (1.3 x 104 CFU/mL). It was observed localized erythema and tissue edema on the palatal mucosa and papillary atrophy on tongue dorsum of these animals. Histologically, microabscesses and inflammatory infiltrate in the palate, as well as fungal invasion in the tongue epithelium were also observed. In the second study, Clx caused weight loss (p=0.001), and reduction in food intake (p=0.008; ANOVA 2-way for the repeated measures/Tukey HSD), respiratory distress, and an increase in GOT (p=0.026) and GPT levels (p = 0.009), and decrease in AP levels (p=0.020; unpaired t-test). Microscopically, higher hepatic alterations (p=0.009; Chi-squared test) were found for NC group and higher gastric alterations (p=0.05), for Chx group, which showed moderate changes (score 3). Conclusion: In the first study, MW sterilized the devices; C. albicans biofilm was formed on their surfaces; denture stomatitis in animals under antibiotic therapy was evidenced macroscopically, microscopically, and histologically. In the second study, Chx gavage administration caused hepatotoxicity and gastric damage.
558

Efetividade da escovação com diferentes agentes de limpeza de próteses na redução da viabilidade de biofilme in vitro da candida albicans /

Pellizzaro, Delise. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Eunice Teresinha Giampaolo / Banca: Cláudia Helena Lovato da Silva / Resumo: A Candida albicans tem sido considerada o principal agente etiológico da estomatite protética, uma das infecções mais comumente observadas em pacientes usuários de próteses removíveis. A adesão de C. albicans à superfície das próteses é o primeiro passo para o desenvolvimento da estomatite protética. Assim, uma adequada higienização das próteses é essencial para prevenir a formação de biofilme microbiano sobre a superfície protética e, conseqüentemente, o início e propagação desta infecção. O objetivo deste estudo foi avaliar a efetividade da escovação com diferentes soluções (água destilada, dentifrício, digluconato de clorexidina a 2%, hipoclorito de sódio a 1% e Polident fresh cleanse®) na redução da viabilidade de um biofilme maduro de C. albicans, desenvolvido sobre uma resina termopolimerizável para base de prótese. Para isso, 90 corpos-de-prova circulares foram confeccionados, esterilizados e inoculados com uma suspensão de 107 células/mL de C. albicans. Para a formação do biofilme, todos os corpos-de-prova foram incubados por 48 h a 37 °C sob agitação. A seguir, os corpos-de-prova foram aleatoriamente divididos (n=9) e individualmente submetidos à escovação ou exposição por 90 s nas diferentes soluções avaliadas. Os espécimes imersos em água destilada pelo mesmo período de tempo foram utilizados como controle positivo. Para verificar a efetividade da escovação e dos agentes de limpeza, os corpos-de-prova foram submetidos à avaliação da atividade metabólica das células não removidas de C. albicans por meio do teste do XTT. Os resultados obtidos foram analisados estatisticamente pelos testes de Mann-Whitney e Kruskal-Wallis (α=0.05). A escovação com todos os agentes de limpeza apresentou redução significativamente superior (p<0,0001) na viabilidade do biofilme quando comparada à exposição dos corpos-de-prova... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The adhesion of C. albicans to surfaces is the prerequisite for occurrence of denture stomatitis, a common disease diagnosed among denture wearers. Therefore, a strict routine of denture cleansing is essential to prevent biofilm formation on the acrylic denture surface and the onset of this infection. Thus, the aim of the current study was to investigate the effectiveness of combining toothbrushing and cleansing agents (dentifrice, 2% chlorhexidine gluconate, 1% sodium hypochlorite, and Polident fresh cleanse®) in inactivating C. albicans biofilm. Circular specimens (10 x 2 mm) of acrylic resin denture base material were made, sterilized, and individually inoculated with C. albicans (1x107 colony-forming units/mL). After incubation (37 °C/48 h), the specimens were divided into 10 experimental groups (n=9): 5 subjected to toothbrushing with different cleansing agents and 4 exposed to the cleansing agents without toothbrushing. Non-cleansed specimens were used as positive controls. The viability of cells was evaluated by XTT reduction method. Mann-Whitney and Kruskal-Wallis tests were used for comparative analysis between the two methods of cleansing and the cleansing agents, respectively (α=0.05). Toothbrushing with all agents was significantly more effective (p<0.0001) in reducing biofilm viability than exposure to the cleansing agents only. Exposure to all cleansing agents reduced significantly (p<0.0001) the biofilm viability, with 2% chlorhexidine gluconate being most effective (p<0.0001). Toothbrushing with 2% chlorhexidine gluconate and 1% sodium hypochlorite resulted in 100% inactivation of the biofilm. The use of cleansing agents as an adjunct to toothbrushing is an effective method to reduce C. albicans biofilm viability on denture base resins. / Mestre
559

Análise da ação antimicrobiana de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio em superfície de liga metálica de cobalto-cromo / Antimicrobial action of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride in cobalt chromium surface

Raile, Priscilla Neves 25 January 2017 (has links)
A ação antimicrobiana de soluções higienizadoras e um aspecto importante a ser avaliado para sua indicação como método associado a escovação, para higienização de Próteses Parciais Removíveis (PPRs). Este estudo avaliou, por meio de metodologia in vitro, a capacidade de soluções higienizadoras em reduzir as unidades formadoras de colônia (UFC) de biofilmes formados sobre a superfície da liga de cobalto cromo (Co-Cr). 240 espécimes metálicos de Co- Cr circulares (12 mm x 3 mm) foram obtidos de padrões de cera confeccionados a partir de uma matriz metálica. Após fundição, os espécimes foram polidos de forma padronizada e esterilizados por oxido de etileno. Divididos aleatoriamente, os espécimes (n=9) foram contaminados com: Candida albicans (Ca), Candida glabrata (Cg), Streptococcus mutans (Sm) ou Staphylococcus aureus (Sa) e biofilme multiespecies (BM), o qual continha todos os microrganismos estudados. A adesão dos microrganismos ocorreu em 1 hora e 30 minutos em estufa incubadora a 37&deg;C. A maturação do biofilme foi obtida em 48 horas, com troca de meio após 24 horas, também a 37&deg;C, sendo que para Sm e BM o processo ocorreu em microaerofilia. Os espécimes contaminados foram imersos em Ricinus communis a 2% (Rc 2%- 20 min), Ricinus communis a 10% (Rc 10%- 20 min), cloreto de cetilpiridinio a 0,05% (Cepacol) (CPC- 10 min), pastilhas efervescentes (NitrAdine) (NA-15 min) e água destilada (AD- 20 min). Após as imersões, os espécimes foram colocados em meio Leethen Broth e agitados para desprendimento das células viáveis. As suspensões obtidas foram diluídas seriadamente (100, 10-1, 10-2, 10-3) e semeadas em meios específicos para contagem das UFC/mL. A partir dos valores de UFC foram calculados os valores de Log10(UFC+1) para análise estatística (&alpha;=0,05). A distribuição dos dados para Sa, Sm em culturas isoladas e para os microrganismos do biofilme multiespécies apresentou-se não normal, tendo sido utilizado o teste de Kruskal-Wallis, seguido pelo teste de Dunn. Para Ca e Cg, a distribuição dos dados apresentou-se normal, tendo sido utilizados ANOVA e teste de Tukey. Em biofilmes isolados, os resultados mostraram eficiência do NA na redução de Cg (p=0,001), Sa (p=0,012) e Sm (p=0,002). Nenhuma das soluções apresentou redução significante de Ca. Dentro do grupo BM, CPC (p=0,035) e NA (p=0,006) reduziram UFC/mL de Cg. NA (p=0,01) foi eficaz contra Sm e nenhuma das soluções apresentou redução de Ca e Sa. Conclui-se que o peróxido alcalino foi o higienizador mais efetivo em relação a maioria dos microrganismos avaliados, mas nenhuma solução apresentou ação contra Ca em superfícies metálicas de Co-Cr. / The evaluation of antimicrobial action of denture cleansers is an important aspect to be investigated to able a denture cleanser to be associated with mechanical method and used to clean removable partial dentures (RPD). This study analyzed in vitro antimicrobial action of cleanser solutions on cobalt chromium (Co-Cr) alloy, reducing the Colony Forming Units (CFU) on biofilms. The specimens (n=240) were obtained from wax patterns (12 mm x 3 mm), made in a metal matrix. Specimens were polished in a standard way and sterilized with ethylene oxide. Randomly divided, the specimens were contaminated with suspension of Candida albicans (Ca), Candida glabrata (Cg), Staphylococcus aureus (Sa), Streptococcus mutans (Sm) and multispecies biofilm (MB), with contained all the microorganisms. The adhesion of microorganisms occurred in 1 hour and 30 minutes in an incubator oven at 37&deg;C. The biofilm growth occurred on 48 hours, with medium change every 24 hours, also at 37&deg;C, while Sm and MB process occurred in microaerophilic. Contaminated specimens were immersed in solutions as the following groups (n=9): A- experimental solution of Ricinus communis 2% (Rc 2%- 20 min.); B- experimental solution of Ricinus communis 10% (Rc 10%- 20 min.); Ccetylpyridiniun chloride 0.500 mg - Cepacol (CPC- 10 min.); D- effervescent tablet - Nitradine (NA- 15 min.); E- distilled water (DW- 20 min.). The specimens were immersed in medium Letheen from which were obtained aliquots. The aliquots were diluted, in 100, 10-1, 10-2 and 10-3, then seeded to determine the number of CFU/ mL. From the CFU values, were calculated values of Log10(CFU+1) for statistical analysis (&alpha;=0,05). The distribution of data was observed in isolated Sa, Sm and all the groups of microorganisms in MB was not-normal. In this case, data were processed and Kruskal-Wallis test (&alpha; = 0.05) followed by Dunn\'s post test were used. In isolated biofilm of Ca e Sa, data presented normal distribution, so ANOVA followed by Tukey post test were used. In isolated biofilms, AP promoted significant reduction of CFU/mL of Cg (p=0.001), Sa (p=0.012), and Sm (p=0.002). None of the solutions presented difference statistic significant of Ca. In MB group, CPC (p=0.035) and AP (p=0.006) significantly reduced CFU/ml of Cg, and AP (p=0.01) of Sm, none of the solutions presented difference of Ca and Sa. It was concluded that alkaline peroxide was the most effective cleanser in reducing the number of CFU in the most of microorganisms, but no one was effective against Ca in Co-Cr metallic surfaces.
560

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Dalva Cruz Laganá / Banca: Eduardo Passos Rocha / Resumo: A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / Abstract: The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants. / Mestre

Page generated in 0.0665 seconds