• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

A utilização da tecnica MIMS na determinação de trialometanos em aguas de abastecimento e a influencia do ion brometo, da amonia e de algas na formação desses compostos

Borges, João Tito 03 August 2018 (has links)
Orientador: Jose Roberto Guimarães / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T17:23:47Z (GMT). No. of bitstreams: 1 Borges_JoaoTito_D.pdf: 1076342 bytes, checksum: 46072743fa4cd122696aa0cfa149d6f1 (MD5) Previous issue date: 2003 / Doutorado
32

Caracteristicas de crescimento de uma linhagem selvagem de Streptococcus thermophilus, sua adesão em superficie de aço inoxidavel e comportamento frente a detergencia e sanificação

Gandara, Ana Lourdes Neves, 1953- 20 October 1995 (has links)
Orientador: Jose Satiro de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-20T18:33:08Z (GMT). No. of bitstreams: 1 Gandara_AnaLourdesNeves_M.pdf: 3743755 bytes, checksum: 3f218d4e0033af33507f6b97386b0038 (MD5) Previous issue date: 1995 / Resumo: Microrganismo selvagem isolado de leite pasteurizado, obtido de processo contínuo de pasteurização HTST com 4 h de operação foi identificado como Streptococcus thermophilus, formando a maior densidade celular em caldo M11 a 45°C em 6h. O número de células viáveis desse microrganismo foi avaliado em meios de cultura PCA, APT, MRS e Ml1 sendo os meios M11 e MRS os que permitiram melhor crescimento. Menores contagens do microrganismo foram observadas no meio APT em relação aos meios anteriores, não ocorrendo crescimento em meio PCA. Em leite foram avaliados o tempo de geração, destruição térmica a 12°C, armazenamento da cultura a 10°C e formação de estruturas de adesão. O microrganismo apresentou um tempo de geração de 15,2 minutos a 45°C e um valor Dn de 1,4 minutos. Na temperatura de 10°C, armazenado por 6 dias, 51,1% das células desse Streptococcus permanecem viáveis; esse microrganismo também forma em 20 h estruturas de adesão em superfícies de aço inoxidável, observada através de microscopia eletrônica de varredura. A produção de ácido lático em leite foi avaliada a 35,40, 45 e 50°C por 8 h, os maiores teores foram obtidos a 45°C (0,35%) e 40°C (0,34%), menores teores ocorreram respectivamente a 50 e 35°C. Em leite a adesão desse S. thermophilus em superfícies de aço inoxidável foi estudada em 6 h de contato a 45°C sob agitação e uma higienização com etapas de limpeza com detergentes alcalino e ácido, seguidas de sanificação foi utilizada para avaliação do comportamento das células aderidas frente à higienização. Esse microrganismo aderiu às superfícies de aço inoxidável produzindo uma carga de 104 células/cm2. Após a limpeza alcalina não foram detectadas células aderidas, porém, em seguida a limpeza ácida, 6 células/cm2 ainda foram detectadas nessa superfície. A sanificação com hipoclorito de sódio a 100 ppm após a limpeza foi suficiente para reduzir a níveis não detectáveis a carga de S. thermophilus selvagem aderidas às superfícies de aço inoxidável / Abstract: A wild microorganism, isolated from HTST pasteurized milk processed in a continuous 4 hour operation, was identified as Streptococcus thermophilus, giving greater celular growth in M17 broth, incubated for 6 hours at 45°C. The viable cell count was evaluated in PCA, APT, :MRS e M17, the media M17 and MRS being shown to allow for better growth. Microorganism lower count was observed in APT in relation to M17 and MRS and no growth occurred in PCA medium. The generation time, thermal destruction at 72°C, storage of the culture at 10°C and formation of adhesive structures were evaluated in milk The organism showed a generation time of 15.2 minutes at 45°C and a Dn value of 7.4 minutes. After storage at 10°C for 6 days, 57.1% of Streptococcus cells remained viable, and organism formed adhesive structures on stainless steel surfaces in 20 hours, these being observed using a scanning eletronic microscope. The production of lactic acid was determined after 8 hours incubation at 35,40,45 and 50°C, greatest values being obtained at 45°C ( 0.35%) and at 40°C (0.34%), lower values being obtained at 50 and 35°C respectively. The adhesion of this S. thermophilus onto stainless steel surfaces was studied afier 6 hours of contact at 45°C with agitation. A cleansing process involving cleaning stages with alkaline and acid detergents followed by sanification was used to evaluate the resistence of the adhered cells. The microorganism adhered to stainless steel surfaces producing a cell load of 104 cells/cm2. After alkaline cleasing, no adhered cells were detected but afier acid cleasing, 6 cells/cm2 were still detected on surface. Cleasing followed by sanification with 100 ppm sodium hypochorite was sufficient to reduce the load of wild S. thermoplilus on the stainless steel surface to non detectable levels / Mestrado / Mestre em Tecnologia de Alimentos
33

Influencia do tempo de armazenagem e da ação dos desinfetantes sobre a estabilidade dimensional e reprodução de detalhes das siliconas por condensação e por adição

Goiato, Marcelo Coelho 22 November 1995 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T18:38:33Z (GMT). No. of bitstreams: 1 Goiato_MarceloCoelho_M.pdf: 4589649 bytes, checksum: b2976b5476ab9c0f66e17cb28b3732d4 (MD5) Previous issue date: 1995 / Resumo: o propósito deste estudo foi verificar a influência do tempo de annazenagem em temperatura ambiente, nos penodos deI, 4 e 24 horas e da desinfecção por imersão durante 30 minutos, sobre a alteração dimensional linear e fidelidade de reprodução de detalhes nas siliconas por condensação e por adição. Foram utilizados neste estudo duas siliconas por condensação (Xantopren e 31 / Abstract: The purpose of this study was to verify the influence of the storage time at room temperature, during the period of 1, 4 and 24 hours and the disinfection by immersion for 30 minutes, on the linear dimensional changing and fidelity of reproduction of details in the silicones by both condensation (Xantopren and 3M) and addition (Express, Extrude and Provil). The work was made according to the recommendation of the specification number 19 of the American Dental Association50 and the review of I.S.O. 4823/198452. For the analysis of the dimensional changing were made 5 pattems for each silicone. The pattems were separated from matrix for 3 minutes besides the recomended. time by the manufacturer and remained in room temperature in different period of time (1, 4 and 24 hours). The readings were made immediatily after pattem separation in an ERNST LEITZ (Germany) comparer microscope and after each storage time. The reproduction fidelity of details was analysed directly in the patems taking into consideration the groove impressions of 20 f..IlIl, 50 J..llIl and 75 f..IlIl depths. The detail observation was made with estereomicroscopio, in a magnification of 16 times. For the disinfection test the silicone pattems were made according to the specification number 19 of the American Dental Association50 and the Review ofI.S.O. number 4823/198452. Five pattems of each silicone were made for the 3 groups: Control, disinfection with Glutasept (4 % formaldehyde) and Glutalabor (2 % glutaraldehyde). The readings of the dimensional changing were made immediately after the obtention of the pattem and after disinfection by 30 mÍnutes in an ERNST LEITZ (Gerrmany) comparer microscope, in the same condition discribed in the test of dimensional changing. The results indicated that the storage time didn't produce significant statistic influence in dimensional changing and details reproduction of siIicones by addition (Express and Extrude). Then, the Provi! showed results with significant statistic differences in the inicial period, when compared to the periods of 4 and 24 hours. There was a significant statistic difference (p<0,05%) in the values of dimensional changing in the silicones by condensation (Xantopren and 3M) in alI storage periods. AlI silicones showed great reproduction of detaiIs, except 3M one, witch didn't reproduce clearIy the lines angIes of the matrix. The results showed that the pattem disinfection in 2% glutaraldeyde and 4% fonnaldehyde for 30 minutes, didn't show significant statistic changing (p<0,05%) in dimensional stabiIity detaiIs reproduction of all silicone pattems / Mestrado / Materiais Dentarios / Mestre em Ciências
34

Efeito da variação da qualidade do efluente final produzido em sistema de lodos ativados convencional no processo de desinfecção. / Effects of the quality variability of activated studge final effluent on the desinfection process.

Inoue, Marta Regina 24 November 2009 (has links)
A operação de uma estação de tratamento de esgotos pode apresentar várias alternativas para condução da desinfecção do efluente final, devendo-se levar em conta os seus custos, benefício, facilidade de instalação, operação, disponibilidade no mercado e as propriedades de cada agente desinfetante. Dentre os diferentes agentes desinfetantes que podem ser empregados o cloro é o que mais tem sido utilizado em função do seu baixo custo, facilidade de operação e também pelos diversos estudos realizados e consolidados com esse agente desinfetante. Desta forma, este trabalho estudou o efeito da variação da qualidade do efluente final produzido em sistemas de lodos ativados convencional no processo de desinfecção utilizando cloro na forma de hipoclorito de sódio. O efluente final empregado na condução dos ensaios experimentais foi gerado pela ETE Jesus Netto, sendo que a instalação piloto consistiu em um tanque de contato com dimensões de 3 metros de comprimento, 3 metros de largura e 0,8 m de altura útil, perfazendo um volume útil igual a 7,2 m³. A dosagem aplicada de agente oxidante foi de 5 mgCl2/L e os tempos de contato avaliados foram de 10 minutos a 30 minutos. Nos ensaios realizados houve a formação de cloraminas, provenientes da nitrificação parcial do processo de lodos ativados da ETE, e em alguns casos também foi observada a presença de cloro residual livre na saída do tanque de contato. Para ensaios de avaliação microbiológica do efluente desinfetado foram observados valores de remoção acima de 5 (expresso como log No/N) para coliformes totais para um tempo de detenção hidráulico superior a 30 minutos e remoção acima de 4 (expresso como log No/N) de coliformes termotolerantes para tempos de detenção hidráulico superior a 20 minutos. ) Para os parâmetros físico-químicos cor aparente, pH, turbidez, nitrogênio amoniacal, demanda química de oxigênio, carbono orgânico total e sólidos suspensos totais não foram observados alterações significativas no afluente e efluente do tanque de contato do processo de desinfecção. Para valores de DBO5,20 inferiores a 20 mg/L e valores de sólidos suspensos totais inferiores a 30 mg/L, não foram observados efeitos no comportamento do processo de desinfecção nos efluentes da ETE Jesus Netto. Os ensaios realizados permitiram avaliar a formação de subprodutos da desinfecção, sendo que os valores de trihalometanos no efluente da água na saída do tanque de contato resultaram abaixo de 10 µg/L. A toxicidade no efluente dos sistemas de lodos ativados convencional foi não detectável. Os bioensaios indicaram que a presença de cloro eleva a toxicidade aguda em Daphnia similis e cloração seguida de descloração produz efluentes sem toxicidade. / The operation of a Wastewater Treatment Plant (WWTP) may present several alternatives with regard to carrying out the final effluent disinfection. One must take into account cost-benefit criteria, easiness of installation and operation, availability in the disinfection market and the properties of each alternative disinfectant. Among the available disinfectant agents that can be put to use, chlorine has been the most widely utilized because of its low cost, easiness of handling and also due to the existing several studies on chlorine disinfection. In this way, this work the effects of quality variability of the final effluent from a conventional activated sludge plant (CASP) on the disinfection process with sodium hypochloride. The final effluent was generated at the Jesus Netto CASP and the pilot scale unit utilized in this work was a contact tank 3 meters long, 3 meters wide and a net depth of 0,8 meters, leading to a net volume of 7.2 m³. The applied free chlorine dose was 5 mg Cl2/L and the utilized contact times were 10 and 30 minutes. During the experimental runs there was formation of chloramines from partial nitrification in the Jesus Netto CASP. In some cases the presence of a free chlorine residual at the outlet of the contact tank was observed. Regarding microbiological evaluation of the disinfected plant effluent, removal efficiencies above 5 logs (expressed as log No/N) were observed for total coliforms with a contact time above 30 minutes and alsothermo tolerant coliform removal efficiencies above 4 logs for hydraulic residence times above 20 minutes. Regarding the physical-chemical variables apparent color, pH, turbidity, ammonia nitrogen, chemical oxygen demand, total organic carbon and total suspended solids, no significant changes in the affluent and effluent of the contact tank were observed. ) For BOD5,20 values below 20 mg/L and TSS values below 30 mg/L, no effects on the tested disinfection process for the Jesus Netto CASP were observed. The experimental runs allowed the evaluation of disinfection byproduct formation. THM levels in the contact tank effluent were below 10 µg/L. No toxicity was detected in the Jesus Netto CASP effluent. Bioassays were conducted and indicated that the presence of chlorine increased the acute toxicity level as evaluated with Daphnia similis and also that CASP effluent chlorination followed by dechlorination produced a disinfected effluent without toxicity.
35

Efeito da imersão em soluções desinfetantes na capacidade de formação de biofilme de C.albicans e características topográficas de uma resina acrílica para base de prótese e um reembasador /

Amaya Arbeláez, Maria Isabel January 2016 (has links)
Orientador: Janaina Habib Jorge / Resumo: O presente estudo teve como objetivo avaliar a capacidade de formação de biofilme de Candida albicans sobre resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase Fast II) de próteses, após imersão diária por períodos de até 6 meses em soluções desinfetantes. Foram confeccionados 360 corpos de prova circulares de cada resina acrílica usando uma matriz metálica (14 x 1,2 mm). As amostras foram imersas overnight durante 0, 1, 3, e 6 meses em 5 soluções desinfetantes: hipoclorito de sódio 0,5%, perborato de sódio 3,8%, digluconato de clorexidina 2%, vinagre de maçã puro (Minhoto®) e água destilada (grupo controle). Após os diferentes períodos de imersão, um biofilme maduro de 48h de C. albicans (cepa ATCC 90028) foi formado sobre os corpos de prova. A capacidade de formação deste biofilme foi analisada utilizando o método de contagem de colônias (UFC/mL) e o ensaio de viabilidade celular Alamar Blue®. Para todos os grupos experimentais, imagens foram obtidas a partir de microscopia eletrônica de varredura (MEV) para avaliação das características topográficas das resinas após a imersão nos diferentes tempos. Todas os experimentos foram realizados em três ocasiões independentes. Análise de variância de três fatores (ANOVA) foi utilizada para avaliar o metabolismo celular (ensaio Alamar Blue®) e os valores de UFC/mL obtidos a partir da formação do biofilme de C. albicans. Foi adotado o nível de significância de 5%. Os resultados de Alamar Blue® mostraram um efeito... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
36

Descontaminação no reuso de bacias para banho com alcool após a limpeza estudo experimental randomizado /

Ramos, Melissa Santiloni Montanha January 2018 (has links)
Orientador: Sílvia Cristina Mangini Bocchi / Resumo: No contexto da prática assistencial hospitalar, percebe-se a despreocupação de se escolher o método de descontaminação, conforme o potencial de risco do material (não-crítico, semicrítico, crítico) em disseminar patógenos e, consequentemente, infecções cruzadas, empregado em cuidados de higiene de pacientes acamados. A contento, indiscriminadamente, bacias de banho têm sido submetidas à desinfecção de baixo nível, com álcool 70% p/v, aplicado por toda extensão por 30 segundos, após limpeza manual com água corrente e detergente neutro seguida de secagem. Contudo, há literatura recomendando para procedimentos de desinfecção intermediários e de baixo nível em superfícies lisas que o tempo de exposição ao álcool etílico ou isopropílico seja ≥ 60 segundos, nas concentrações de 60 a 90% p/v. Objetivo geral. Avaliar a eficácia do álcool 80% p/v, aplicado por 30 e 60 segundos, no processamento manual de bacias de banho inoxidáveis, após limpeza com água corrente e detergente neutro. Método. Estudo experimental randomizado, com delineamento anterior-posterior, unicego, realizado em centro único (Hospital Público do Estado de São Paulo), em unidade de internação, com média de 150 banhos mensais. Com poder de 80% e confiabilidade de 95%, estimou-se amostra mínima de 50 bacias igualmente distribuídas aleatoriamente em dois grupos: 25 no grupo 30s e 25 no grupo 60s, utilizando-se teste de proporções pareado (dois momentos). Testes microbiológicos antes e após às intervenções foram realiza... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction. In the hospital care practice context, the lack of concern for choosing the decontamination method, according to the risk potential of the material (non-critical, semi critical, critical) in disseminating pathogens and, consequently, cross-infection, used in hygiene of bedridden patients. Indiscriminately, bath bowls have been subjected to low level disinfection with 70% w/v alcohol, applied for 30 seconds at all times, after manual cleaning with running water and neutral detergent followed by drying. However, there is a literature recommending for intermediate and low-level disinfection procedures on smooth surfaces that the time of exposure to ethyl or isopropyl alcohol is ≥60 seconds at concentrations of 60 to 90% w/v. General objective. To evaluate the efficacy of 80% w / v alcohol, applied for 30 and 60 seconds, in the manual processing of stainless bath bowls, after cleaning. General objective. To evaluate the efficacy of 80% w/v alcohol, applied for 30 and 60 seconds, in the manual processing of stainless bath bowls, after cleaning with running water and neutral detergent. Method. A randomized experimental study, with an anterior-posterior design, single-blind, performed in a single center (Public Hospital of the State of São Paulo), in an inpatient unit, with an average of 150 monthly baths. With 80% power and 95% reliability, a minimum sample of 50 basins was randomly distributed in two groups: 25 in the 30s group and 25 in the 60s group, using a paired... (Complete abstract click electronic access below) / Mestre
37

Aplicação de radiação UV para desinfecção de efluente da associação de reator UASB e biofiltro aerado submerso / UV radiation application for sewer disinfection of the UASB reactor association with aerated submerged biofilter (ASB)

Silva, Silvia Sônia da 20 September 2007 (has links)
Essa pesquisa investigou e interpretou aspectos relevantes da desinfecção por radiação ultravioleta (UV) na inativação de microrganismos indicadores. O efluente sanitário foi proveniente de tratamento anaeróbio (Reator UASB), seguido de Biofiltro Aerado Submerso, em escala real. A pesquisa foi dividida em duas etapas, sendo que na primeira foi dado destaque ao estudo das características operacionais da unidade ultravioleta. Na segunda etapa da pesquisa objetivou-se o estudo da resistência de diferentes microrganismos indicadores à radiação ultravioleta e das possíveis correlações entre as variáveis testadas. Os resultados obtidos na primeira etapa da pesquisa forneceram indicativos de que a limpeza das lâmpadas emersas pode ser feita em períodos superiores a 2 meses, devendo-se levar em consideração também a fragilidade do sistema. A limpeza do canal de desinfecção não teve relação com a eficiência de desinfecção. A operação de unidades UV é relativamente simples desde que haja treinamento dos operadores e condições ergonômicas favoráveis ao trabalho dos mesmos. O custo operacional situou-se na faixa de 0,006 R$/\'M POT.3\' de esgoto desinfetado e o custo de energia elétrica foi de 0,07 R$/\'M POT.3\' de esgoto desinfetado. As eficiências máximas de desinfecção encontradas na segunda etapa da pesquisa foram de 100% para Colifagos, 99,999% para CF (Coliformes Fecais) e 99,993% para CT (Coliformes Totais), o que demonstra que a ordem decrescente de resistência desses organismos é CT > CF > Colifagos. Os resultados indicaram que houve pouca variação da eficiência de inativação para as três lâminas de esgoto testadas (3 cm, 4 cm e 5 cm) o que sugere que a unidade é capaz de atender aumentos moderados de vazão, confirmando os pressupostos adotados no seu dimensionamento. Os dados obtidos a partir do ensaio hidrodinâmico indicaram que o reator de desinfecção testado comporta-se como um sistema composto de um reator pistonado ideal com presença de curtos circuitos hidráulicos. / This research has investigated and interpreted relevant aspects of disinfection by ultraviolet radiation (UVR) in the inativation of indicator microorganisms\' inactivation. The sanitary effluent was provided by anaerobic treatment (UASB reactor), followed by aerated submerged biofilter (ASB), on a real scale. This research was divided into two stages, whereas in the first stage, operational characteristics of the ultraviolet unit studies were highlighted. The aim of the second stage of the research was the resistance of different indicator microorganisms to ultraviolet radiation study and the possible relation among variables tested. Results obtained in the first stage of the research have provided indication that the cleaning of submerged lamps may be done in periods longer than two months, however the fragility of the system must be considered. Disinfection channel cleaning should not be related to the disinfection efficiency. The operation of UV units is relatively simple, as long as the operators are trained and work under favorable ergonomic conditions. The operational cost was set at 0.006 R$/\'M POT.3\' of disinfected sewer system and the electrical energy cost was set at 0.07 R$/\'M POT.3\'. The maximum efficiency found on the disinfection of the research second stage were 100% for Coliphages, 99.999% for FC and 99.993% for TC, which demonstrates that the resistance decreasing order of these organisms is TC > FC > Coliphages. Results indicated that there was a low inactivation efficiency variation for the three tested sewer samples (3 cm, 4 cm and 5 cm), which suggests that the unit is capable of serving moderate increase of flow, confirming adopted predictions in its dimensioning. Information obtained from the hydrodynamic test indicated that the tested disinfection reactor behaves as a compound system of an ideal piston reactor with hydraulic short circuits.
38

Efeito da variação da qualidade do efluente final produzido em sistema de lodos ativados convencional no processo de desinfecção. / Effects of the quality variability of activated studge final effluent on the desinfection process.

Marta Regina Inoue 24 November 2009 (has links)
A operação de uma estação de tratamento de esgotos pode apresentar várias alternativas para condução da desinfecção do efluente final, devendo-se levar em conta os seus custos, benefício, facilidade de instalação, operação, disponibilidade no mercado e as propriedades de cada agente desinfetante. Dentre os diferentes agentes desinfetantes que podem ser empregados o cloro é o que mais tem sido utilizado em função do seu baixo custo, facilidade de operação e também pelos diversos estudos realizados e consolidados com esse agente desinfetante. Desta forma, este trabalho estudou o efeito da variação da qualidade do efluente final produzido em sistemas de lodos ativados convencional no processo de desinfecção utilizando cloro na forma de hipoclorito de sódio. O efluente final empregado na condução dos ensaios experimentais foi gerado pela ETE Jesus Netto, sendo que a instalação piloto consistiu em um tanque de contato com dimensões de 3 metros de comprimento, 3 metros de largura e 0,8 m de altura útil, perfazendo um volume útil igual a 7,2 m³. A dosagem aplicada de agente oxidante foi de 5 mgCl2/L e os tempos de contato avaliados foram de 10 minutos a 30 minutos. Nos ensaios realizados houve a formação de cloraminas, provenientes da nitrificação parcial do processo de lodos ativados da ETE, e em alguns casos também foi observada a presença de cloro residual livre na saída do tanque de contato. Para ensaios de avaliação microbiológica do efluente desinfetado foram observados valores de remoção acima de 5 (expresso como log No/N) para coliformes totais para um tempo de detenção hidráulico superior a 30 minutos e remoção acima de 4 (expresso como log No/N) de coliformes termotolerantes para tempos de detenção hidráulico superior a 20 minutos. ) Para os parâmetros físico-químicos cor aparente, pH, turbidez, nitrogênio amoniacal, demanda química de oxigênio, carbono orgânico total e sólidos suspensos totais não foram observados alterações significativas no afluente e efluente do tanque de contato do processo de desinfecção. Para valores de DBO5,20 inferiores a 20 mg/L e valores de sólidos suspensos totais inferiores a 30 mg/L, não foram observados efeitos no comportamento do processo de desinfecção nos efluentes da ETE Jesus Netto. Os ensaios realizados permitiram avaliar a formação de subprodutos da desinfecção, sendo que os valores de trihalometanos no efluente da água na saída do tanque de contato resultaram abaixo de 10 µg/L. A toxicidade no efluente dos sistemas de lodos ativados convencional foi não detectável. Os bioensaios indicaram que a presença de cloro eleva a toxicidade aguda em Daphnia similis e cloração seguida de descloração produz efluentes sem toxicidade. / The operation of a Wastewater Treatment Plant (WWTP) may present several alternatives with regard to carrying out the final effluent disinfection. One must take into account cost-benefit criteria, easiness of installation and operation, availability in the disinfection market and the properties of each alternative disinfectant. Among the available disinfectant agents that can be put to use, chlorine has been the most widely utilized because of its low cost, easiness of handling and also due to the existing several studies on chlorine disinfection. In this way, this work the effects of quality variability of the final effluent from a conventional activated sludge plant (CASP) on the disinfection process with sodium hypochloride. The final effluent was generated at the Jesus Netto CASP and the pilot scale unit utilized in this work was a contact tank 3 meters long, 3 meters wide and a net depth of 0,8 meters, leading to a net volume of 7.2 m³. The applied free chlorine dose was 5 mg Cl2/L and the utilized contact times were 10 and 30 minutes. During the experimental runs there was formation of chloramines from partial nitrification in the Jesus Netto CASP. In some cases the presence of a free chlorine residual at the outlet of the contact tank was observed. Regarding microbiological evaluation of the disinfected plant effluent, removal efficiencies above 5 logs (expressed as log No/N) were observed for total coliforms with a contact time above 30 minutes and alsothermo tolerant coliform removal efficiencies above 4 logs for hydraulic residence times above 20 minutes. Regarding the physical-chemical variables apparent color, pH, turbidity, ammonia nitrogen, chemical oxygen demand, total organic carbon and total suspended solids, no significant changes in the affluent and effluent of the contact tank were observed. ) For BOD5,20 values below 20 mg/L and TSS values below 30 mg/L, no effects on the tested disinfection process for the Jesus Netto CASP were observed. The experimental runs allowed the evaluation of disinfection byproduct formation. THM levels in the contact tank effluent were below 10 µg/L. No toxicity was detected in the Jesus Netto CASP effluent. Bioassays were conducted and indicated that the presence of chlorine increased the acute toxicity level as evaluated with Daphnia similis and also that CASP effluent chlorination followed by dechlorination produced a disinfected effluent without toxicity.
39

Aplicação de radiação UV para desinfecção de efluente da associação de reator UASB e biofiltro aerado submerso / UV radiation application for sewer disinfection of the UASB reactor association with aerated submerged biofilter (ASB)

Silvia Sônia da Silva 20 September 2007 (has links)
Essa pesquisa investigou e interpretou aspectos relevantes da desinfecção por radiação ultravioleta (UV) na inativação de microrganismos indicadores. O efluente sanitário foi proveniente de tratamento anaeróbio (Reator UASB), seguido de Biofiltro Aerado Submerso, em escala real. A pesquisa foi dividida em duas etapas, sendo que na primeira foi dado destaque ao estudo das características operacionais da unidade ultravioleta. Na segunda etapa da pesquisa objetivou-se o estudo da resistência de diferentes microrganismos indicadores à radiação ultravioleta e das possíveis correlações entre as variáveis testadas. Os resultados obtidos na primeira etapa da pesquisa forneceram indicativos de que a limpeza das lâmpadas emersas pode ser feita em períodos superiores a 2 meses, devendo-se levar em consideração também a fragilidade do sistema. A limpeza do canal de desinfecção não teve relação com a eficiência de desinfecção. A operação de unidades UV é relativamente simples desde que haja treinamento dos operadores e condições ergonômicas favoráveis ao trabalho dos mesmos. O custo operacional situou-se na faixa de 0,006 R$/\'M POT.3\' de esgoto desinfetado e o custo de energia elétrica foi de 0,07 R$/\'M POT.3\' de esgoto desinfetado. As eficiências máximas de desinfecção encontradas na segunda etapa da pesquisa foram de 100% para Colifagos, 99,999% para CF (Coliformes Fecais) e 99,993% para CT (Coliformes Totais), o que demonstra que a ordem decrescente de resistência desses organismos é CT > CF > Colifagos. Os resultados indicaram que houve pouca variação da eficiência de inativação para as três lâminas de esgoto testadas (3 cm, 4 cm e 5 cm) o que sugere que a unidade é capaz de atender aumentos moderados de vazão, confirmando os pressupostos adotados no seu dimensionamento. Os dados obtidos a partir do ensaio hidrodinâmico indicaram que o reator de desinfecção testado comporta-se como um sistema composto de um reator pistonado ideal com presença de curtos circuitos hidráulicos. / This research has investigated and interpreted relevant aspects of disinfection by ultraviolet radiation (UVR) in the inativation of indicator microorganisms\' inactivation. The sanitary effluent was provided by anaerobic treatment (UASB reactor), followed by aerated submerged biofilter (ASB), on a real scale. This research was divided into two stages, whereas in the first stage, operational characteristics of the ultraviolet unit studies were highlighted. The aim of the second stage of the research was the resistance of different indicator microorganisms to ultraviolet radiation study and the possible relation among variables tested. Results obtained in the first stage of the research have provided indication that the cleaning of submerged lamps may be done in periods longer than two months, however the fragility of the system must be considered. Disinfection channel cleaning should not be related to the disinfection efficiency. The operation of UV units is relatively simple, as long as the operators are trained and work under favorable ergonomic conditions. The operational cost was set at 0.006 R$/\'M POT.3\' of disinfected sewer system and the electrical energy cost was set at 0.07 R$/\'M POT.3\'. The maximum efficiency found on the disinfection of the research second stage were 100% for Coliphages, 99.999% for FC and 99.993% for TC, which demonstrates that the resistance decreasing order of these organisms is TC > FC > Coliphages. Results indicated that there was a low inactivation efficiency variation for the three tested sewer samples (3 cm, 4 cm and 5 cm), which suggests that the unit is capable of serving moderate increase of flow, confirming adopted predictions in its dimensioning. Information obtained from the hydrodynamic test indicated that the tested disinfection reactor behaves as a compound system of an ideal piston reactor with hydraulic short circuits.
40

Indicadores microbiológicos e físico-químico no reprocessamento de endoscópios e as interfaces de monitoramento - Brasil/Austrália / Microbial and physical-chemical indicators on endoscope reprocessing and monitoring interface - Brazil/Australia

Santos, Lissandra Chaves de Sousa 28 July 2017 (has links)
As dificuldades do reprocessamento dos endoscópicos gastrointestinais, o risco de contaminação e os casos de infecções representam desafios amplamente conhecidos na comunidade cientifica. Neste sentido, investigou-se o reprocessamento de endoscópios gastrointestinais subsidiado nos níveis de sujidade, contaminação microbiana e presença de biofilme. Trata-se de um experimento laboratorial realizado em três fases por meio da bioluminescência com adenosina trifosfato (ATP) para avaliação do nível de sujidade; polimerase chain reaction (PCR) para carga bacteriana e cultura microbiana para determinação do nível de contaminação. Ainda, avaliou-se as superfícies internas de canais de endoscópios por microscopia eletrônica de varredura (MEV) quanto à presença de biofilme. A análise estatística dos dados foi subsidiada em medidas de tendência central, testes de Man-Whitney, Wilcoxon e Spearman, p<0,05, por meio do software IBM SPSS Statistics versão 23.0. A avaliação de 99 endoscópios antes e após limpeza manual demonstrou a eficácia do processo na redução de sujidade (p<0,001) e contaminação microbiana (p=0,03), inclusive com baixo percentual da amostra com micro-organismos viáveis. Dos 75 endoscópios avaliados após o reprocessamento evidenciou-se uma redução do nível de sujidade (todos com <50URL, interna e externamente); entretanto a presença de carga bacteriana foi de 3log de bactéria/mL e 10,6% de positividade das culturas. Os micro-organismos isolados dos lavados de endoscópios após o reprocessamento foram Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus hominis, Staphylococcus capitis, Roseomonas gilardii e Micrococcus luteus. Na avaliação dos canais de biópsia de endoscópios provenientes do Brasil observou-se maior contaminação do que os da Austrália (p<0,001). Todos os canais apresentaram biofilme e danos em suas superfícies, entretanto as amostras brasileiras apresentaram particularidades, como, presença de hemácias, neutrófilos e fungos. Assim, observou-se que apesar da baixa carga microbiana nos endoscópios há o risco potencial de infecção cruzada associado ao biofilme, ameaçando a qualidade e segurança do reprocessamento. Adiciona-se a necessidade de avanços tecnológicos e científicos contra o biofilme na prática do reprocessamento de endoscópios / The difficulties on gastrointestinal endoscope reprocessing, contamination risk and outbreaks are a recognized challenge in science. It was investigated gastrointestinal endoscope reprocessing for dirtiness, contamination level and presence of biofilm. Laboratorial experiment performed in three phases using adenosine triphosphate (ATP) bioluminescence for dirtiness evaluation; polymerase chain reaction (PCR) for bacterial load and microbial culture for contamination level evaluation. In addition, it was evaluated biofilm on endoscope channels internal surfaces by scanning electron microscopy (SEM). Statistics analysis was performed by descriptive analysis, ManWhitney, Wilcoxon and Spearman tests, p<0,05, using IBM SPSS Statistics versão 23.0. Before and after cleaning analysis of 99 endoscopes showed it efficacy on reducing dirtiness (p<0,001) and microbial contamination level (p=0,03), including a small percentage of culturable microorganism. From 75 endoscopes tested after reprocessing demonstrated dirtiness level reduction (all samples <50RUL, from internal and external area); but, also, presence of bacterial load of 3 log of bacteria/mL and 10,6% of culture positive. The microorganisms isolated from endoscope flush after reprocessing were Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus hominis, Staphylococcus capitis, Roseomonas gilardii and Micrococcus luteus. Endoscope biopsy channel analysis showed that samples from Brazil had higher contamination level than the ones from Australia (p<0,001). All channels analyzed presented biofilm and damage on their surfaces, however Brazilian samples showed particularities, like, blood cells, neutrophils and fungus. So, ever with low microbial load on endoscopes there is a potential risk of crossinfection associated with biofilm, compromising reprocessing quality and safety. Additionally, there´s the need of scientific and technologic improvement on endoscope reprocessing against biofilm

Page generated in 0.0317 seconds