• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 327
  • 199
  • 61
  • 42
  • 41
  • 40
  • 39
  • 34
  • 30
  • 29
  • 28
  • 28
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise de propriedades mecânicas e microscópicas de um gesso tipo IV após incorporação de derivados da clorexidina

Lucas, Matheus Guilherme [UNESP] 22 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-22Bitstream added on 2014-06-13T19:44:50Z : No. of bitstreams: 1 lucas_mg_dr_arafo.pdf: 7609787 bytes, checksum: 818d8660089a22ed3354bf205e9bb72b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram analisadas as alterações nas propriedades físicas e mecânicas de um gesso odontológico do tipo IV após a incorporação de dois agentes desinfetantes (Digluconato e Cloridrato de clorexidina). Foram realizados testes mecânicos para a análise do tempo de presa, reprodução de detalhes, expansão de presa e resistência à compressão, já as alterações físicas foram analisadas através de uma microscopia eletrônica de varredura (MEV) nos aumentos de 375, 750, 1500 e 3000x. Os resultados demonstraram que somente houve alterações significantes no tempo de presa com a incorporação de Digluconato de Clorexidina 2,0% sem diluição e a resistência a compressão que demonstrou valores significantemente inferiores em todas as incorporações, porém todas as alterações dentro do limite estabelecido pela normatização para gessos odontológicos. Pela análise da Microscopia Eletrônica de Varredura, pode-se observar que os cristais obtiveram um aumento pela associação com os agentes derivados da clorexidina diminuindo os microporos existentes. Com isso verificamos que os derivados da clorexidina podem ser uma alternativa para a obtenção de modelos biologicamente seguros. / The purpose of this study was to evaluate the alterations in physical and mechanical properties of a gypsum tipe IV after the incorporation of two disinfectant agents (Chlorhexidine hydrochlooride and Chlorhexidine gluconate). The mechanical tests are made for setting time, reproduction details, setting expansion and compressive tensile, and the physical properties was examinated in a scanning electron microscope (SEM) and photomicrographed are made in 375, 750,1500, 3000x and compared vissually. The results demonstrated were only significant alterations in the setting time with the incorporation of Chlorhexidine gluconate without dilution and the compression resistance that demonstrated under values in all of the incorporations, however all the alterations meet inside of the established limit for I.S.O values. In the analysis of the physical properties, the crystals obtained an increase for the association with the derived agent´s clorhexidine. In conclusion, the incorporation clorhexidine agents can be a alternative to obtained biological models in dentistry.
72

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
73

Efeito da polimerização e desinfecção na resistência flexural e na topografia da superfície de resina acrílica

Oliveira, Derly Tescaro Narcizo de [UNESP] 15 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-15Bitstream added on 2014-06-13T18:56:44Z : No. of bitstreams: 1 oliveira_dtn_me_araca.pdf: 464380 bytes, checksum: 604c14584189497c81a25c41ad98c57e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A ação dos produtos desinfetantes sobre as propriedades físico-químicas da resina acrílica norteia sua seleção para a higienização de aparelhos ortodônticos removíveis. Avaliou-se a resistência à fratura de resina acrílica ativada quimicamente após ciclagem em diferentes soluções desinfetantes. Foram confeccionados quarenta corpos de prova com resina acrílica autopolimerizável incolor (Clássico,Ind.&Com.Ltda./Brasil) utilizando-se matriz metálica retangular e circular, seguindo-se às técnicas de polimerização sob pressão úmida (imersão em água/n=20) e sob pressão seca (sem água/n=20) foram subdivididos em 4 grupos (n=5), conforme a solução utilizada para ciclagem: água destilada (Controle), bicarbonato de sódio, hipoclorito de sódio 1% e Corega®Tabs. A ciclagem consistiu em imersão em 100 ml da solução por 10 minutos três vezes ao dia e, em seguida, manutenção em recipiente fechado contendo saliva artificial a 37ºC. Este ciclo foi realizado durante 30 dias, trocando-se as soluções e a saliva a cada procedimento executado. Na sequência os espécimes foram submetidos ao ensaio de resistência flexural a três pontos foi utilizada máquina EMIC DL3000, à velocidade de 5mm/min, dispondo-se as amostras em suporte contendo dois apoios de sustentação, sendo aplicada força axial e equidistante aos dois outro pontos até a ruptura do corpo-de-prova. Os espécimes circulares foram levados para leitura em Microscópio de Força Atômica (AFM - V Nanoscope Veeco). Os resultados, submetidos à análise de variância (P<0,001 ) e o Teste de Tuckey (P<0,05) não apontaram diferenças significantes para a resistência flexural. Conclui-se que os métodos de polimerização e as soluções testadas não modificaram a resistência flexural... / The disinfectant products action on the physicochemical properties of acrylic resin guides its selection to the cleaning of removable orthodontic appliances. The fracture resistance of acrylic resin after cycling in different disinfectant solutions was evaluated. Forty specimens were made with colorless acrylic resin (Clássico, Ind. & Com.Ltda. / Brazil), using matrix, followed by the techniques of polymerization under wet pressure (immersion in water / n = 20) and dry pressure (no water / n = 20). The samples were divided into 4 groups (n = 5) as the solution used for cycling: distilled water (Control), sodium bicarbonate, sodium hypochlorite 1% and Corega®Tabs. The cycling consisted of immersion in 100 ml of solution for 10 minutes three times a day and then maintained in a closed container containing artificial saliva at 37 º C. These cycles were conducted during 30 days, changing the solutions and artificial saliva for each procedure performed. Latter, the specimens were submitted to surface analysis with Atomic Force Microscope (AFM - Veeco Nanoscope V). A machine, EMIC DL3000, was used for the three-point flexural strength test, speed of 5mm/min, providing the sample in medium containing two restraints support. After that axial force was applied and equidistant to the two other points to the body to break the specimens. The results were submitted to analysis of variace(P<0,001) and Tuckey Test (P<0,05) showed no significant differences in flexural strength test. The Atomic Force Microscopy analysis revealed less topographical roughness for the group Corega®Tabs. We conclude that the polymerization methods and solutions tested did not alter the flexural strength of the material studied except the comparation between... (Complete abstract click electronic access below)
74

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química /

Moreno, Amália. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Eduardo Piza Pellizzer / Banca: Humberto Gennari Filho / Banca: Simone Cecílio Hallak Regalo / Banca: Célia Regina Moreira Lanza / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Abstract: Considering that ocular prostheses restore esthetics and patient's self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / Doutor
75

Efeito da irrigação e medicação endodôntica em dentina infectada por biofilmes orais

Ronald Ordinola Zapata 07 June 2013 (has links)
O objetivo desse estudo foi avaliar o efeito antimicrobiano da irrigação e da medicação endodôntica em dentina infectada por biofilmes orais. Na primeira parte do estudo, avaliaram-se as seguintes soluções irrigadoras: hipoclorito de sódio a 1%, clorexidina a 2%, ácido cítrico a 10% e EDTA a 17%. Na segunda parte, avaliaram-se soluções irrigadoras contendo associações (MTAD, Smear Clear, Qmix, ácido maleico a 7%, iodo-iodeto de potássio a 2% e ácido peracético a 4%), sendo essas soluções comparadas a 2 concentrações de hipoclorito de sódio. Na terceira parte, avaliou-se o efeito de dispositivos sônicos, ultrassônicos e de laser na capacidade de limpeza do hipoclorito de sódio a 6%, com uso de microscópio eletrônico de varredura. Na quarta parte, avaliaram-se os efeitos antimicrobianos de 3 pastas de hidróxido de cálcio contendo 3 radiopacificadores diferentes (óxido de zinco, sulfato de bário e iodofórmio). No último experimento, foram avaliadas as propriedades antimicrobianas da pasta triantibiótica, da clorexidina em gel e da pasta aquosa de hidróxido de cálcio. Os resultados mostraram que todas as soluções de hipoclorito de sódio testadas e o ácido peracético a 4% foram mais efetivas sobre o biofilme em comparação a todos os irrigantes testados. As soluções de hipoclorito de sódio propiciaram significativamente uma melhor limpeza da dentina. O ácido peracético foi também efetivo para dissolver células do biofilme. A ativação do hipoclorito de sódio com o ultrassom e com laser interferiu favoravelmente na limpeza da dentina infectada. A pasta triantibiótica e o hidróxido de cálcio associado ao iodofórmio foram os medicamentos mais efetivos na descontaminação da dentina infectada. Portanto, o protocolo ideal que deve ser adotado para garantir uma descontaminação efetiva da dentina contaminada por biofilmes orais inclui o uso de hipoclorito de sódio ativado por ultrassom ou laser e medicação intracanal de hidróxido de cálcio com iodofórmio. O ácido peracético e a pasta triantibiótica apresentaram resultados promissores. / The aim of this study was to evaluate the antimicrobial effect of endodontic irrigation and medication on biofilm infected dentin. In the first part, we evaluated the following irrigant solutions: 1% sodium hypochlorite, 2% chlorhexidine, 10% citric acid and 17% EDTA. In the second part, irrigant solutions containing combinations of antimicrobials such as \"MTAD,\" \"Smear Clear\", \"Qmix\", 7% maleic acid and 2% iodine-potassium iodide and 4% peracetic acid were evaluated. These solutions were compared to 2 concentrations of sodium hypochlorite. In the third part, we evaluated the effect of sonic, ultrasonic and laser irrigation on the cleaning ability of biofilm infected dentin using 6% sodium hypochlorite under scanning electron microscope. In the fourth part, we evaluated the antimicrobial effects of 3 calcium hydroxide pastes containing 3 different radiopacifiers (zinc oxide, barium sulfate and iodoform). In the last experiment, we evaluated the antimicrobial properties of the triantibiotic paste, 2% chlorhexidine gel and calcium hydroxide paste. The results showed that the sodium hypochlorite and the peracetic acid solutions were more effective to decontaminate the biofilm infected dentin in comparison to all of the tested irrigants. The sodium hypochlorite solutions allowed significantly better cleaning of the dentine. The peracetic acid was also effective to dissolve the biofilm cells. Activation of 6% sodium hypochlorite with ultrasonic and laser increased the cleaning of biofilm infected dentin. The triantibiotic paste and calcium hydroxide associated to iodoform were the most effective intracanal dressings available for the decontamination of the infected dentin. Therefore, the ideal protocol to be adopted in order to ensure an effective decontamination of biofilm infected dentin includes the use of sodium hypochlorite, specially activated by ultrasound or laser; and the use of calcium hydroxide with iodoform intracanal dressing. The peracetic acid and the triantibiotic paste also showed promising results.
76

Contaminação microbiana de hemodialisadores processados pelo método automatizado e manual após o número máximo de reusos / Microbiological contamination of reprocessed dialyzers after maximal number of reuses

Alexandra do Rosario Toniolo 04 December 2014 (has links)
Introdução: A hemodiálise é um procedimento invasivo, para pacientes em falência renal onde se realiza a filtração do sangue continuamente, utilizando-se circulação extracorpórea em um filtro hemodialisador. No Brasil, a prática do reuso de hemodialisadores atinge quase 100% nos serviços de diálise. Uma das justificativas para o reuso são os limitados recursos para a assistência à saúde. No entanto, esta prática, causa questionamentos relacionados à segurança. Erros técnicos no reprocessamento, qualidade da água e alteração da integridade da membrana do hemodiliasador podem afetar a qualidade do processamento expondo os pacientes ao risco de bacteriemia e sepse. Objetivo: Avaliar a contaminação microbiana dos hemodialisadores após o número máximo de reusos permitidos, comparando os resultados conforme tipo de processamento: manual e automatizado. Método: Esta pesquisa caracterizou-se como estudo de campo, transversal, de caráter exploratório comparativo em dois serviços de diálise. A composição da amostra foi por conveniência conforme a disponibilidade destas, pelas instituições doadoras, sendo os grupos experimentais compostos por 11 hemodialisadores processados pelo método automatizado e quatro hemodialisadores processados manualmente. As amostras foram coletadas após o processamento obedecendo ao número máximo de reusos permitidos pela RDC ANVISA nº 11/2014, sendo 12 reusos para processamento manual e 20 reusos para processamento automatizado. Em Cabine de Proteção Biológica a solução salina e dialisadora foram drenadas dos compartimentos de sangue e dialisato, respectivamente, e injetados 150 mL de meio de cultura Tioglicolato de Sódio Fluido em cada compartimento. As amostras foram incubadas em estufa microbiológica por 14 dias, a temperatura de 35 ºC ±2ºC. Após esse período alíquotas do meio de cultura foram semeadas em meios de ágar sangue, anaerinsol e sabouraud, capazes de recuperar a maioria dos microrganismos aeróbios, anaeróbios, bolores e leveduras. As placas foram incubadas por 48 horas a 35 ºC ±2ºC, e procedida a identificação de gênero dos micorganismos. Realizados controles positivos com hemodialisadores contaminados intencionalmente e controles negativos, com novos esterilizados. Resultados: Das amostras submetidas ao processamento automatizado três amostras (3/11-27,3%) apresentaram crescimento microbiano no compartimento de sangue, sendo identificados dois diferentes microrganismos: de Sphingomonas paucimobilis (66,67%) e de Penicillium sp. (33,33%). Todas as amostras 11/11 (100%) apresentaram crescimento microbiano no compartimento de dialisato, sendo identificados 5 diferentes microrganismos: Sphingomonas paucimobilis (43,75%), Strenotrophomonas maltophilia (25%), Pseudomonas aeruginosa (18,75%), Acinectobacter baumannii (6,25%) e Candida sp (6,25%). Dos quatro hemodialisadores submetidos ao processamento manual, uma amostra (25%) apresentou crescimento de bacilo Gram-positivo no compartimento de sangue e uma amostra (25%) apresentou crescimento no compartimento do dialisato contaminados por três microrganismos distintos: de Bacillus sp, Rhizobium radiobacter, Burkholderia sp. Comparando os resultados da contaminação microbiana segundo os dois métodos de processamento analisados não houve diferença estatisticamente significante (p=1) para o compartimento de sangue. Para o compartimento do dialisato o método automatizado apresentou maior número amostras positivas em relação ao manual (p=0,008791). Conclusão: Os resultados demonstraram que o reuso dos hemodialisadores não é uma prática recomendada, podendo causar bacteriemia e sepse em pacientes em tratamento hemodialítico. Ressalta-se que a pesquisa foi conduzida no pior cenário após o número máximo de reusos permitidos sem determinar em qual número de reusos a contaminação aconteceu. / Introduction: Hemodialysis is an invasive procedure for patients with kidney failure in which blood is continuously filtered using a dialyzer filter through extracorporeal blood flow. In Brazil dialyzers are nearly 100% reused in dialysis facilities. One of the main justifications to reuse dialyzers is economical. However, this practice often leads to concerns related to patient safety. Technical errors in reprocessing, water quality and the membrane dialyzer degradation may lead to different risks including bacteremia and sepsis. Objective: To evaluate dialyzers regarding microbiological contamination after maximal number of reuses, comparing results in accordance with the type of reprocessing: manual and automated. Method: This research was characterized as a transversal, exploratory and comparative in two dialysis facilities. The sample was composed as convenience according to the availability of the facilities which donated the samples. The experimental groups were composed of 11 automated reprocessed dialyzers and four manually reprocessed dialyzers. The samples were collected after reprocessing in dialysis facilities according to the maximal number of reuses permited by law (12 in manual reprocessing and 20 in automated reprocessing) and prepared in Biosafety Cabinets. Saline Solution and dialysate solution were drained from both the blood and the dialysate chambers, respectively, by applying suction and filled with 150 mL of culture medium sodium thioglicolato fluid in each chamber and they were incubated at a temperature of 35 º C + or -2 ° C for 14 days. After this period, the samples were cultured in medium adequate for the growth of aerobic and anaerobic organisms as well as fungi and yeasts.The samples were incubated for 48 hours at 35 º C + or -2 ° C and identification of microorganisms was carried. Results: The analyzed samples which were automated reprocessed, 3/11(27.3%) showed microbiological growth in the blood chamber, of this total, we identified two different microorganisms: S.paucimobilis (66,67%) and Penicillium sp. (33,33%). In the dialysate chamber 11/11 (100%) of microbiological growth was identified, of this total we identified five different microorganisms: S.paucimobilis (43,75%) , S. maltophilia (25%) , P. aeruginosa (18,75%) , A. baumannii (6,25%) and Candida sp. (6,25%). The four analyzed samples which were manually reprocessed, 1/4(25%) showed microbiological growth in the blood chamber. One sample with Gram-positive Bacillus was identified in the dialysate chamber and contaminated by Bacillus sp, R. Radiobacter and Burkholderia sp. Comparing the results related to microbiological growth according to the two methods in the blood chamber, we concluded that there was no statistically significant difference (p=1) and in the dialysate chamber, there was a higher number of positive samples among those which were automated reprocessed compared to manually reprocessed (p = 0.008791) Conclusion: The results showed that dialyzers reuse is not a recommended practice and may cause bacteremia and sepsis for patients with chronical kidney disease. We highlight that this study was carried out considering the worst case scenario ,i.e. after the maximal number of reuses permitted by law, without specifying in which number of reuses the contamination occurred.
77

Desempenho de reatores biológicos aeróbios de leito fluidizado inverso na remoçao de carga orgânica

Zim, Graziela January 2006 (has links)
Este estudo avaliou a eficiência de reatores biológicos aeróbios de leito fluidizado inverso na remoção de matéria orgânica quando submetidos a diferentes condições operacionais (vazão de recirculação e carga orgânica aplicada). O experimento, em escala de laboratório, foi realizado em três reatores cilíndricos (R1, R2 e R3) com altura total de 2,00 m, diâmetro interno de 0,10 m e volume útil de 15,70 L. Como meio suporte para o desenvolvimento do biofilme foram utilizadas partículas de polipropileno (PP) em volume equivalente a 40% do volume útil do reator. O afluente entrava nos reatores pelo topo e saía pelo fundo e o oxigênio era fornecido através de um aerador poroso. Os reatores R1, R2 e R3 foram operados com vazão de recirculação de 2,50 L/min, 4,00 L/min e 5,50 L/min, respectivamente, durante todo período experimental. Os reatores foram alimentados com esgoto sintético caracteristicamente doméstico e o experimento consistiu de três etapas, conforme a carga orgânica aplicada: Etapa de Menor Carga – 0,70 Kg DQO/m3.dia; Etapa de Carga Intermediária – 1,70 Kg DQO/m3.dia e Etapa de Maior Carga – 3,90 Kg DQO/m3.dia. A vazão de alimentação foi mantida constante durante todo período experimental correspondendo ao TDH de 12 horas.O acompanhamento dos reatores foi realizado com medidas de DQO, sólidos livres (suspensão) e aderidos (biofilme). Foi determinada também a velocidade ascensional das biopartículas no meio líquido, tendo como motivo a identificação das possíveis causas da expansão excessiva ocorrida durante a realização do experimento. Os resultados obtidos demonstraram elevada eficiência de remoção carbonácea em termos de DQO, com médias superior a 93% na etapa de Carga Intermediária e em torno de 90% para a etapa de Maior Carga. Conforme avaliação estatística, não houve evidências de que a vazão de recirculação tenha efeito sobre a eficiência de remoção carbonácea. O aumento da carga orgânica afluente reduziu de forma significativa a eficiência de remoção carbonácea apenas no reator de menor vazão de recirculação. Em relação à quantidade de sólidos voláteis, o aumento da vazão de recirculação resultou em aumento dos sólidos voláteis aderidos, porém não foi identificado efeito sobre a quantidade de sólidos voláteis livres.O aumento de carga aplicada resultou em aumento significativo na quantidade média de sólidos voláteis livres nos reatores. Quanto aos sólidos voláteis aderidos, o acréscimo de carga afluente repercutiu de forma diferente nos três reatores: para a menor vazão de recirculação houve redução na massa de sólidos voláteis aderidos, para a vazão de recirculação intermediária ocorreu aumento da massa de sólidos voláteis aderidos e para a maior vazão de recirculação o aumento da carga aplicada não influenciou a quantidade de sólidos aderidos voláteis presentes no reator. A velocidade ascensional média das biopartículas diminuiu com o aumento da vazão de recirculação, significando que quanto maior a vazão de recirculação maior a densidade das biopartículas. / This study evaluated the efficiency of down flow aerobic fluidized bed reactors for the removal of organic mater submitted to different operational conditions (recirculation flow and applied organic load). The experiment was run on 3 cylindrical lab scale reactors (R1, R2 and R3) with 2 m total height, 0.10 m internal diameter and working volume of 15.70 L. Polypropylene particles were used as the support material for the development of the biofilm occupying 40% of the working volume of the reactors. The influent were applied at the top of the columns and withdraw from the bottom and the oxygen was supplied throughout a porous stone. The reactors R1, R2 and R3 were operated with recirculation flow of 2,50, 4.00 and 5.50 L. min-1, respectively, throughout the experimental work.The reactors were fed with synthetic wastewater similar to sanitary wastewater and the experiment was performed in 3 steps, according to the applied organic loading rate, namely: Lower Load - 0,70 Kg COD/m3.dia; Intermediate Load - 1,70 Kg COD/m3.dia; Higher Load - 3,90 Kg COD/m3.dia. The feeding flow was maintained constant throughout the experiment to obtain HDT equal to 12 hours. The reactors were monitored with conventional parameters such as COD, free suspended solids and attached suspended solids (biofilm). The upflow velocity of the bioparticles in the liquid phase was also determined with the purpose to identify the potential causes of the excessive expansion of the bed observed during the experimental work. The experimental results demonstrated high efficiency of carbonaceous COD removal, with average values above 93 % during the Intermediate Load step and around 90 % for the Higher Load. According to statistical evaluation, the recirculation flow did not provided significant effect upon the carbonaceous organic matter removal. The increase in applied organic load caused a significant decrease only to the reactor operated with the lower recirculation flow. Regarding the amount of volatile solids, the increase of the recirculation flow resulted in the increase of the attached volatile solids, however it was not identified any effect upon the amount of free volatile solids. The increase of applied organic load resulted in significant increase of the amount of the free volatile solids in the reactors. Regarding the attached volatile solids, the increase of applied organic load resulted in misleading behavior of the reactors, as follows: the lower recirculation flow resulted in a reduction of the amount of attached volatile solids; the intermediate recirculation flow resulted in an increase of the attached volatile solids, while it was not observed any significant variation in the amount of attached volatile solids inside the reactor operated with the higher recirculation flow. The average accession velocity of the bioparticles decreased with the increase of the recirculation flow, implying that the recirculation flow resulted in higher values of the bioparticles density.
78

Ocorrencia de oocistos de Cryptosporidium spp. e cistos de Giardia spp. em uma estação de tratamento de esgoto : avaliação das eficiencias do processo de lodo ativado na remoção e de desinfecção por luz ultravioleta na inativação desses patogenos / Occurence of oocysts Cryptosporidium spp. and cysts Giardia spp. in the wastewater treatment plant : evaluation of removal efficiency of activated sludge process and the desinfection by UV light in inactivation these pathogens

Santos, Luciana Urbano dos 08 March 2007 (has links)
Orientador: Regina Maura Bueno Franco / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-08T19:15:28Z (GMT). No. of bitstreams: 1 Santos_LucianaUrbanodos_D.pdf: 2872201 bytes, checksum: 3d486b0bfc4357c133c090e92209db49 (MD5) Previous issue date: 2007 / Resumo: Entre muitas doenças de veiculação hídrica, a criptosporidiose e a giardiose são de particular interesse para a Saúde Pública, porque oocistos de Cryptosporidium spp e cistos de Giardia spp. podem persistir por longos períodos no ambiente, sendo que estes dois protozoários patogênicos têm sido implicados como a causa de muitos surtos epidêmicos de gastroenterites nos últimos 25 anos.Em muitos desses surtos, o esgoto doméstico foi incriminado como a fonte de contaminação do manancial; os variados métodos de tratamento de esgoto não removem totalmente agentes patogênicos, evidenciando a necessidade de desinfecçãodo esgoto tratado antes do seu lançamento no corpo hídrico. Uma forma de tratamento de esgoto amplamente utilizada é o processo por Iodos ativados, onde a degradação da matéria orgânica é realizada por bactérias aeróbicas.Em função da resistência de Cryptosporidium spp e Giardia spp. Ao processode desinfecção por cloração, a radiação por luz ultravioleta (UV) têm sidoavaliada como um processo alternativo. Para avaliar a eficiência de remoção de oocistose cistos pelo processo de Iodo ativado e de um reator de luz UV em inativaroocistos e cistos em uma Estação de Tratamento de Esgoto (ETE) da cidadede Campinas, 3 tipos de amostras foram selecionados para o estudo: I) afluente (n=53), iii) efluente desinfetado por luz UV (n=38) e, iii) efluente sem desinfecção por luz UV (n=53). As amostras de afluente foram concentradas por centrífugo-concentraçãoe as amostras de efluente (desinfetadas ou não por luz UV) foram processadas por filtração em membrana de éster de celulose) e, a visualizaçãodos protozoários, feita pela reação de imunofluorescência direta, com anticorposmonoclonais. A avaliação do processo de desinfecção por luz UV foi realizada com experimento de infectividade animal, inoculando-se 14/ cistos camundongos da linhagem BALB!c nude. Cistos de Giardia spp foram mais freqüentes e em maior densidade nos três tipos de amostras. Oocistos de Cryptosporidiumspp. foram observados somente em 2 amostras de afluente e em apenas uma amostra de efluente desinfetado por luz UV. O tratamento de esgoto pelo processo de Iodo ativado reduziu 98,9 % dos cistos e 99,7 % dos oocistos. A administração intragástrica de cistos de Giardia spp. desinfetados ou não por luz UV em camundongos, resultou na liberação de cistos de Giardia spp., nas fezes e trofozoítos foram observados nas lâminas confeccionadas por aposição do intestino. Estes resultados indicam que a desinfecção por luz UV não foi completamente eficiente na inativação dos cistos de Giardia spp, no caso da ETE estudada / Abstract: Among many water-borne diseases the cryptosporidiosis and giardiosis are of particular public health interest, because Cryptosporidium spp. oocysts and Giardia spp. cysts can persist for long periods in the environment, and both pathogenic protozoa have been implicated as the cause of many outbreaks of gastroenteritisin the last 25 years. In many of those outbreaks, the domestic sewer was incriminated as to source of contamination of the spring; they varied treatment sewage approaches do not remove entirely agent's pathogens, showing up the need of disinfection of the treated effluent before of their launching in the water body.A form of address of sewer broadly utilized is the trial by activated sludge whichway the degradation of the organic matter is carried out by aerobic bacteria and, in function of the resistance of Cryptosporidium spp and Giardia spp. to the chlorinedisinfection, the ultraviolet light (UV) has been evaluated like an alternative trial of disinfection. In order to evaluate the efficiency of cysts and oocysts removal by the activated sludge process, and by a UV reactor in inactivating cysts and oocystsin one Wastewater Treatment Plant (Wl/VTP)in Campinas, three sampling points were selected for study: i) influent (n=53),iii) treated effluent with UV disinfection (n=38) and iii) treated effluent without UV disinfection (n=53). The influent samples were concentrated by centrifugation and effluent samples (disinfectedwith UV light or not) were processed by cellulose esters membrane filtration, and protozoan visualization was analyzed by fluorescent monoclonal antibodytests. The investigation of disinfection potential by UV light was made with infectivityassay. Each mice of linage BALB/c nude were intragastrically inoculated a mean dosage 14 cysts. Giardia spp cysts prevailed with higher density in the three different sample types. Cryptosporidium spp. oocysts were observed in only 2 samples of influent and in just one sample of treated sewage with UV disinfection.The treatment by the activated sludge process promoted a reduction of 98.9% of cysts and 99.7 % of oocysts. Gastric intubation of Giardia spp. Cysts disinfected ar not by UV light to mice resulted in cysts released in feces and trophozoiteswere also observed toa in intestinal scrapings. The findings of this study indicate that disinfection by UV light was not completely efficient regarding the inactivationof Giardia spp cysts in the case of the / Doutorado / Doutor em Parasitologia
79

Radiação ultravioleta e ozônio aplicados como métodos alternativos de desinfecção de efluentes secundários de esgoto sanitário / Alternatives methods for the disinfection of wastewater secondary effluents applying ultraviolet radiation and ozone

Virgínia Dantas Dias 29 June 2001 (has links)
A cloração é largamente utilizada para a desinfecção de águas de abastecimento e residuárias, porém o potencial de toxicidade da cloração por seus subprodutos torna o processo menos atrativo. O dióxido de cloro surge como alternativa de desinfecção, porém a sua geração envolve reações bastante dependentes das concentrações de reagentes, das condições físico-químicas, podendo gerar também subprodutos prejudiciais à saúde humana. Outras tecnologias alternativas, como o ozônio e a radiação ultravioleta apareceram como processos tecnicamente viáveis. Neste trabalho buscou-se realizar revisão crítica da literatura existente sobre a desinfecção realizada com radiação ultravioleta e ozônio, bem como investigar e interpretar os aspectos relevantes do desempenho da desinfecção de efluentes de esgoto sanitário com ozônio e com radiação ultravioleta na inativação de coliformes totais e coliformes fecais. Na parte experimental avaliou-se as doses de 80, 95 e 120 mg/L e tempos de contato de 20, 30 e 35 minutos para a desinfecção com ozônio. Na desinfecção com radiação ultravioleta, utilizou-se de tempos de exposição de 10, 30, e 60 segundos, mantendo-se a mesma intensidade média de radiação e variando-se a espessura de lâmina líquida. Nos aspectos observados no decorrer desta pesquisa, verificou-se que para as condições analisadas, a desinfecção com radiação ultravioleta mostrou-se como técnica mais simples e eficaz para a inativação de coliformes fecais e coliformes totais quando comparada à ozonização, apresentando assim vários aspectos favoráveis no que concerne ao modo de operação, a influência da qualidade do efluente bruto, ao controle do processo, entre outros. / The Chlorinate is widely used for the disinfection of waste and drinking water, however the toxicity potential by the by-products of chlorinate renders the process less attractive. The chlorine dioxide comes up as a disinfection alternative, but its production involves highly reagent concentration and physical-chemical condition dependant reactions, also being able to create human health hazardous by-products. Other alternative technologies, like ozone and ultraviolet radiation have risen as technically viable processes. It this work, is has been attempted to review critically the existing literature about the effluent disinfection of sanitary waste, using a comparative approach between the disinfection in which ozone and ultraviolet radiation were used, as well as to investigate and interpret the relevant aspects of sanitary waste effluents disinfection with ozone and ultraviolet radiation on the inactivation of otal and fecal coliforms. In the experimental part doses of 80, 95 and 120 mg/L and contact times of 20, 30 and 35 minutes have been evaluated for the ozone disinfection process. For the ultraviolet method, exposure times of 10, 30 and 60 seconds have been used, keeping the same mean intensity of radiation and varying water layer thickness. With regard to the observed of thios research, is has been verified that, for the analyzed conditions, the ultraviolet disinfection has showed the simplest and most effective method of the inactiviation of fecal andtotal coliforms when compared the ozone method, thus showing several favorable aspects concerning the operation mode, the wal effuent quality influence, the process control, among others.
80

O impacto da fricção, solução de limpeza e subsequente desinfecção de alto nível na remoção de biofilme buildup-5 e de biofilme tradicional-5 em canais endoscópicos gastrointestinais flexíveis / The impact of friction, and cleaning solution and subsequent high-level disinfection in removal cyclic buildup biofilm and cyclic biofilm on flexible endoscopic gastrointestinal channels

Maíra Marques Ribeiro 22 August 2016 (has links)
Introdução: Biofilme consiste em um conjunto de microrganismos embutidos em uma matriz extracelular. O biofilme tradicional (TBF) se desenvolve em locais com contínua hidratação, e o biofilme buildup (BBF), em produtos para a saúde expostos a repetidos ciclos de sujidade, limpeza, desinfecção e secagem. Objetivo: avaliar o impacto do uso de detergente e fricção para remover biofilme buildup-5 (BBF-5) e biofilme tradicional-5 (TBF-5) de canais endoscópicos gastrointestinais flexíveis, bem como o impacto do glutaraldeído após a limpeza. Métodos: O BBF-5 foi desenvolvido após a exposição da superfície interna dos canais de endoscópicos gastrointestinais ao Artificial Test Soil (ATS) contendo 108UFC/ml de Pseudomonas aeruginosa (PA) e Enterococcus faecalis (EF), limpeza, desinfecção de alto nível (DAN), enxágue e secagem durante cinco dias. O mesmo processo foi utilizado para desenvolver o TBF-5, porém a fase de DAN foi omitida. Limpeza com detergentes com enzimas de pH neutro e detergentes sem enzimas com pH alcalino, escova com cerdas e dispositivo de limpeza pull thru foram comparados à limpeza com água e sem fricção para remover o BBF-5 e o TBF-5. Testes de proteína e carboidrato, contagem de bactérias viáveis e adenosina trifosfato (ATP) foram realizados. Teste de Kruskal-Wallis e análise de post hoc Dunn-Bonferroni foram realizados. Resultados: Não houve diferença estatisticamente significante (p>0,05) entre a quantidade de EF e PA nos canais com TBF-5 e BBF-5. Não houve diferença da eficácia para a remoção de PA em TBF-5 entre o detergente enzimático e a água, em ambas as situações, a limpeza apenas não foi eficaz (p>0,05) na ausência de fricção (flush). Por outro lado, o detergente alcalino, associado a todos os procedimentos de limpeza (ausência e presença de fricção) e DAN, foi eficaz para remoção de PA. Para a remoção de EF em TBF-5, a eficácia da limpeza foi alcançada em todas situações avaliadas (com e sem fricção) com o uso do detergente enzimático; com a água, na presença de fricção (pull thru e escovas de cerdas); e com detergente alcalino, apenas com o método de limpeza com escovas de cerdas (p<0,05). Para a remoção de bactérias em BBF-5, formados em canais de PTFE, não houve diferença da eficácia para a remoção de PA entre o detergente enzimático e o alcalino, em ambas situações, todos os procedimentos avaliados foram eficazes (p<0,05), enquanto que a água foi ineficaz para remoção de PA apenas na ausência de fricção (p>0,05). Para a remoção de EF em BBF-5, o detergente enzimático e a água foram eficazes em todas situações avaliadas; o detergente alcalino, foi eficaz na presença de fricção com o dispositivo pull thru e escovas de cerdas (p<0,05). Testes de ATP, proteína e carboidrato foram incapazes de detectar biofilme. Conclusão: Água potável de torneira, detergente com enzimas e detergente alcalino sem enzimas foram eficazes para a completa remoção de BBF-5 e TBF-5 na presença de fricção (pull thru ou escova com cerdas) durante a limpeza. Na ausência de fricção, detergente enzimático apresentou maior habilidade para remover E. faecalis de TBF-5 e BBF-5, detergente alcalino para remover P. aeruginosa e a água não foi eficaz para a remoção de ambos microrganismos. Glutaraldeído destruiu bactérias remanescente após a maioria das combinações de limpeza avaliadas. / Background: Biofilm is the accumulation of microorganisms enclosed in an extracellular matrix. Traditional biofilm (TBF) develops under continuous hydration whereas buildup biofilm (BBF) develops on medical devices that are exposed to repeated cycles of soiling, cleaning, disinfection and drying. Objetive: to evaluat the impact of detergent and friction on BBF-5 and and TBF-5 removal from PTFE channels as well as the killing efficacy of glutaraldehyde post cleaning. Methods: BBF-5 was developed by repeated rounds over five days of exposure to bacteria, cleaning, high level disinfection (HLD), rinsing and drying of the inner surface of new polytetrafluorethylene (PTFE) channels. Artificial Test Soil (ATS) containing 108CFU/ml of Pseudomonas aeruginosa (PA), and Enterococcus faecalis (EF) was used for the bacterial exposure. The same process was used to develop TBF-5, however the HLD step was omitted. Cleaning with enzymatic and alkaline detergents, bristle brush and pull thru cleaner were compared to a water-flush only to determine BBF-5 and TBF-5 removal. The residual organic and microbial levels were tested using carbohydrate, and protein assays as well viable count, and adenosine triphosphate (ATP) testing. Kruskal-Wallis test and the post hoc Dunn-Bonferroni analysis were performed. Results: There was not a statistically significant difference (p> 0.05) between the amount of EF and PA in the channels with TBF-5 and BBF-5. There was not a difference in efficacy for the removal of PA in TBF- 5 between the enzymatic detergent and water and in both situations, only cleaning was not effective (p>0.05) in the absence of friction (flush). Furthermore, the alkaline detergent, associated with all cleaning procedures (absence and presence of friction) and DAN, was effective for the removal of PA. For removal of EF in TBF-5, cleaning efficacy was achieved in all procedures evaluated (with and without friction) with the use of enzymatic detergent; with water in the presence of friction (pull thru and bristle brushes); and an alkaline detergent, the only method of cleaning brushes with bristles (p<0.05). For the removal of bacteria in BBF-5 formed on PTFE channels, there was not a difference in efficacy for PA removal of the enzymatic and alkalyne detergent and in both situations, all procedures were evaluated effective (p<0.05 ), while water was ineffective for PA removal only in the absence of friction (p>0.05). For EF removal on BEF-5, the enzymatic detergent and water were evaluated effective in all situations; alkaline detergent, was effective in the presence of friction with the pull thru device and bristle brushes (p<0.05). ATP, protein and carbohydrate testing were unable to detect biofilm. Conclusion: Tap water, enzymatic and alkaline detergent were effective for complete BBF-5 and TBF-5 removal in the presence of friction (pull thru or bristle brush) and a flushing pump during the cleaning. Without friction, enzymatic detergent was more effective for EF removal of TBF-5 and BBF-5, alkalyne detergent was more effective for PA removal and water was not effective for both types of bacterial removal. Glutaraldehyde effectively killed the remaining microorganisms after some cleaning combinations were tested.

Page generated in 0.0469 seconds