• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 148
  • 86
  • 45
  • 8
  • 6
  • 5
  • 2
  • Tagged with
  • 300
  • 181
  • 39
  • 38
  • 29
  • 27
  • 26
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Charakterisierung eines schnellen Diamantdetektors als Proton-Bunch-Monitor für die Reichweiteverifikation in der Protonentherapie

Werner, Rahel-Debora 26 September 2022 (has links)
Für die Reichweiteverifikation in der Protonentherapie mittels Prompt Gamma-Ray Timing (PGT) wird ein Proton-Bunch-Monitor (PBM) benötigt, um Phaseninstabilitäten zwischen den Protonen-Mikropulsen und der Radiofrequenz (RF) des Zyklotrons zu eliminieren. In dieser Arbeit wurde demonstriert, dass ein Diamantdetektor diese anspruchsvolle Aufgabe erfüllen kann. Dazu wurde ein polykristalliner Diamantdetektor in diversen Experimenten umfassend charakterisiert. An ELBE wurde eine Zeitauflösung von 82(6) ps für minimal-ionisierende Elektronen bestimmt. Die Auflösung bei der Detektion von Protonen klinischer Energien wurde am OncoRay ermittelt und betrug im Mittel 314(17) ps. Des Weiteren wurden Experimente durchgeführt, die auf die optimale Position des Detektors in der späteren klinischen Anwendung nahe des Degraders schließen lassen. Bei der Anwendung als PBM konnte der Diamantdetektor Phasenverschiebungen zur RF mit einer zeitlichen Auflösung von weniger als 3 ps bei einem Messintervall von 30 ms detektieren. Diese Phasenverschiebungen konnten auch in weiten Teilen durch das Phasenkontrollsignal U_phi, welches im Rahmen dieser Arbeit erstmalig ausgewertet wurde, bestätigt werden. Mit dem Diamantdetektor und U_phi stehen nun zwei PBM zur Verfügung, mit denen ein zentrales Problem bei der klinischen Anwendung von PGT als Reichweite-Verifikationsmethode gelöst werden kann.:1 Motivation 2 Grundlagen der Reichweiteverifikation in der Protonentherapie 2.1 Wechselwirkung von geladenen Teilchen mit Materie 2.2 Tiefendosiskurven 2.3 Praktische Aspekte der Protonentherapie 2.4 Reichweiteunsicherheiten 2.5 Prompt Gamma-Ray Timing (PGT) 2.6 Proton-Bunch-Monitore (PBM) 3 Entwicklung eines Vorverstärkers für den Diamantdetektor 3.1 Untersuchungen mit Generatorsignalen 3.2 Untersuchungen mit radioaktiven Prüfstrahlern 3.3 Ergebnisse 4 Bestimmung der Zeitauflösung am Elektronenstrahl 4.1 Bestimmung der Zeitauflösung eines Detektors mit einer Flugzeitmessung 4.2 Experimenteller Aufbau 4.3 Datenerfassung 4.4 Ergebnisse 4.5 Zusammenfassung 5 Bestimmung der Zeitauflösung am klinischen Protonenstrahl 5.1 Experimentalraum am OncoRay 5.2 Experimenteller Aufbau 5.3 Bestimmung der Zeitauflösung eines Detektors mit einer Koinzidenzmessung 5.4 Ablauf der Messung 5.5 Datenerfassung 5.6 Ergebnisse 5.7 Diskussion 5.8 Zusammenfassung 6 Optimierung der Position des Diamantdetektors am Degrader 6.1 Vorbetrachtungen 6.2 Experimenteller Aufbau 6.3 Ergebnisse 6.4 Diskussion 6.5 Zusammenfassung 7 Einsatz des Diamantdetektors als PBM 7.1 Experimenteller Aufbau 7.2 Datenerfassung 7.3 Ablauf der Messung 7.4 Ergebnisse 7.5 Diskussion und Ausblick 7.6 Zusammenfassung 8 Zusammenfassende Diskussion A Anhang A.1 Produktzertifikat des Diamantdetektors A.2 Zertifikate der radioaktiven Prüfstrahler A.3 Feinzeit-Korrektur beim U100-Spektrometer A.4 Zeitdifferenz-Histogramme für Variante A1 und A2 des Koinzidenzexperiments A.5 Der Diamantdetektor als PBM bei automatischer Phasenanpassung A.6 Der Diamantdetektor als PBM bei manueller Phasenanpassung Literaturverzeichnis Abbildungsverzeichnis Tabellenverzeichnis Liste der verwendeten Akronyme Danksagung und Eigenständigkeitserklärung
32

Testování křemíkových detektorů ITk beta zářičem pro experiment ATLAS Upgrade / Beta Source Tests of Semiconductor Detectors ITk for ATLAS Upgrade

Kovanda, Ondřej January 2019 (has links)
Beta Source Tests of Semiconductor Detectors ITk for ATLAS Upgrade Abstract: The ATLAS experiment is due to undergo a major upgrade for the High Luminosity phase of the LHC operation. In particular, the current tracking system (ID) will be replaced by full-silicon ITk. IPNP laboratories are involved in R&D of SCT detector modules for ITk. Low-temperature β-source tests of the R0 FR 5 module prototype were the main focus of this thesis. After testing the cooling cycle, 11 threshold scans were performed on two ABC130 chips, yielding the median collected charge ranging between 2.9 ± 0.2 fC and 3.1 ± 0.2 fC for chip #6 at SNR from 16.0 ± 1.0 at 24 ◦ C to 22.7 ± 1.5 at −15 ◦ C. No trend with temperature was observed outside the error bars. The results are in accordance with previous similar measurements. Question of fitting the median collected charge in various units was adressed and equivalence of the fits was determined. The ability of IPNP laboratories to perform low-temperature β-source tests was proven.
33

Metoda napěťového kontrastu v ESEM / Method of Voltage Contrast in ESEM

Buchta, Michal January 2008 (has links)
This graduation thesis deals with the problem of voltage contrast in ESEM. The purpose of this work was to verify influence of used detectors in the dependence on conditions in specimen chamber on the size of voltage contrast. With the conditions in specimen chamber we understand pressure and working conditions of signal detection. We used power transistor as specimen.
34

Detekce QRS založená na vlnkové transformaci / QRS detection based on wavelet transform

Zedníček, Vlastimil January 2014 (has links)
This thesis deals with implementation of detector QRS complex with use of wavelet transform. The first part is focused on formation and possibility to measure cardiac activity. The other part of thesis we will familiarise with the different possibilities of detection QRS complex and we intimately focus on wavelet transform that will be used for a project of detection QRS complex. The practical part of thesis focuses on the project of detector in programming language Matlab and his different setting. This projected detector has been tested with CSE database. Achieved results of projected detector are evaluated with the results of others authors.
35

Implementace metody snímání spektra v obvodu FPGA / Spectrum sensing implementation in FPGA

Maňas, Ondřej January 2015 (has links)
The aim of this thesis is a software modelling and hardware implementation of spectral sensing algorithm based on cyclostationary based detection. A proposed detector is fully implemented in FPGA and further tested under measurements in real RF environment.
36

Modernizace vnitřního detektoru ATLAS / Modernizace vnitřního detektoru ATLAS

Mészárosová, Lucia January 2016 (has links)
The main goal of this master thesis is, at first, to describe upcoming upgrade of ATLAS experiment in CERN in Switzerland and to describe the principle of strip silicon detectors. Then it is measurement and analysis of data from laser tests with two lasers: red and infra-red. Last but not least goal is to document the method of measurement and analysis of laser tests for the future laser tests. The text of the thesis is divided into five chapters. The first chapter is dedicated to the research facility CERN, its present experiment ATLAS and future experiment ATLAS Upgrade. The second chapter explains properties of semiconductors and the principle of strip semiconductor detectors. The third chapter describes whole measurement layout: a lab for testing, equipment needed for the tests and the whole system functioning. In the fourth chapter there are actual results from the laser tests. The tests were done on two end-cap prototype modules for ATLAS Upgrade with strip silicon sensors using two lasers: red and infra-red. The last chapter briefly explains the functions of macros that were created for measuring and analysing data from laser tests.
37

Selbstkalibrierende Verfahren in der parallelen Magnetresonanztomographie / Self-calibrating methods for parallel magnetic resonance imaging

Blaimer, Martin January 2005 (has links) (PDF)
In der klinischen Magnetresonanztomographie (MRT) spielt neben dem Bildkontrast und der räumlichen Auflösung, die Messzeit eine sehr wichtige Rolle. Auf Grund schneller Bildgebungsmethoden und technischer Fortschritte in der Geräteentwicklung konnten die Aufnahmezeiten bis auf wenige Sekunden reduziert werden. Somit wurde die MRT zu einem der wichtigsten Verfahren in der klinischen Diagnostik. Der größte Fortschritt für eine weitere Verkürzung der Aufnahmezeiten erfolgte durch die Einführung von Partiell-Parallelen-Akquisitions (PPA) Techniken in den späten 1990er Jahren. Inzwischen sind PPA-Verfahren etabliert und stehen auch für den Einsatz im klinischen Alltag zur Verfügung. Die Grundlage aller PPA-Verfahren bildet eine Anordnung von mehreren Empfangsdetektoren, welche gleichzeitig und unabhängig voneinander ein Objekt abbilden. Das Signal jedes einzelnen Detektors enthält dabei je nach Position eine gewisse räumliche Information. Eine Messzeitverkürzung wird im Allgemeinen dadurch erzielt, dass die Menge der aufzunehmenden Daten reduziert wird. Dies führt zu Fehler behafteten Bildern auf Grund von fehlenden Daten. Alle gängigen PPA-Verfahren benutzen die in der Detektoranordnung inhärente räumliche Information, um mit geeigneten Algorithmen die Fehler behafteten Bilder zu korrigieren. Die beiden erfolgreichsten Ansätze stellen momentan das "Sensitivity Encoding" (SENSE) Verfahren und die "Generalized Autocalibrating Partially Parallel Acquisitions" (GRAPPA) Methode dar. Die Leistungsfähigkeit von PPA-Methoden ist allerdings beschränkt. Zunächst begrenzt die Anzahl der Einzeldetektoren den maximal erreichbaren Messzeitgewinn. Weiterhin führt der Einsatz von PPA-Verfahren zu einer Verringerung des Signal-zu-Rausch-Verhältnis (englisch: signal-to-noise ratio, SNR). Im Allgemeinen ist das SNR um den Faktor der Wurzel des Beschleunigungsfaktors verringert. Ein zusätzlicher SNR-Verlust entsteht durch den Rekonstruktionsprozess und ist stark abhängig von der geometrischen Anordnung der Detektoren. Auf Grund dieser Verluste ist der Einsatz von PPA-Methoden auf Applikationen mit bereits hohem intrinsischen SNR beschränkt. In dieser Arbeit werden Erweiterungen von PPA-Verfahren vorgestellt, um deren Leistungsfähigkeit weiter zu verbessern. Der Schwerpunkt liegt dabei auf der selbstkalibrierenden GRAPPA-Methode, welche die fehlenden Daten im reziproken Bildraum, dem so genannten k-Raum, rekonstruiert. Zunächst wird der Einsatz von GRAPPA für die 3D-Bildgebung beschrieben. In der 3D-Bildgebung ist es für die Rekonstruktionsqualität von PPA-Methoden vorteilhaft, die Daten entlang zweier Raumrichtungen zu reduzieren. GRAPPA war bisher auf Experimente mit Datenrekonstruktion in nur einer Richtung beschränkt. Es wird gezeigt, dass sich durch Kombination mit SENSE der Vorteil einer zwei-dimensionalen Datenreduktion erstmals auch für GRAPPA benutzen lässt. Weiterhin wird eine Neuformulierung der GRAPPA-Rekonstruktion als Matrixoperation vorgestellt. Dieser Formalismus wird als GRAPPA-Operator Formalismus bezeichnet und erlaubt es, ein gemessenes Signal im k-Raum zu verschieben, um fehlende Daten zu rekonstruieren. Eigenschaften und Beziehungen zwischen unterschiedlichen Verschiebungen werden beschrieben und daraus resultierende Anwendungen für die 2D- und 3D-Bildgebung präsentiert. Im Allgemeinen arbeiten alle konventionellen PPA-Verfahren ausschließlich auf der Rekonstruktionsseite. Somit ist die Bildqualität und damit der erzielbare Messzeitgewinn nur durch die Geometrie der Detektoranordnung beeinflussbar. In der Mehrschicht-MRT lässt sich diese Abhängigkeit von der Detektoranordnung reduzieren, indem Bildartefakte bereits während der Datenaufnahme gezielt verändert werden. Auf diese Weise kann der SNR-Verlust aufgrund des Rekonstruktionsprozesses minimiert werden. Dieses Konzept der kontrollierten Einfaltungen (englisch: Controlled Aliasing in Parallel Imaging Results in Higher Acceleration, CAIPIRINHA) wird für den Einsatz in der dynamischen Herzbildgebung vorgestellt. Bei geringen Beschleunigungsfaktoren kann mit CAIPIRINHA im Gegensatz zu den üblichen PPA-Verfahren eine Bildqualität erzielt werden, welche keine signifikanten Einbußen gegenüber konventionellen Experimenten aufweist. / In clinical magnetic resonance imaging (MRI) applications, scan time plays an important role. Due to the introduction of fast imaging sequences and hardware developments, acquisition times have been reduced to the order of several seconds and for this reason, MRI has become one of the most important techniques in clinical diagnosis. The greatest improvement in further reducing the acquisition times has been the development of partially parallel acquisition (PPA) strategies in the late 1990s. Today, PPA strategies have become established and are available for clinical routine examinations. The basis for all PPA methods is an array of mutiple detectors which allow the independent and simultaneous imaging of an object. According to its position, each detector receives signal predominantly from a localized region and therefore contains spatial information. In general, a scan time reduction is achieved by reducing the amount of acquired data. This results in imaging artifacts. PPA methods utilize the spatial information inherent in the detector array in order to remove these artifacts by using dedicated reconstruction algorithms. At present, the most successful PPA strategies are the "Sensitivity Encoding" (SENSE) method and the "Generalized Autocalibrating Partially Parallel Acquisitions" (GRAPPA) technique. However, the performance of PPA methods is limited. First, the achievable scan time reduction factor is limited by the number of detectors in the array. Second, compared with a conventional experiment the signal-to-noise ratio (SNR) is decreased by the square root of the scan time reduction factor. An additional decrease in SNR is introduced by the reconstruction process and is strongly dependent on the array geometry. For these reasons, the application of PPA methods is restricted to applications with a high intrinsic SNR. In this thesis, extensions of standard PPA methods are presented which improve their performance. Special emphasis is put on the autocalibrating GRAPPA technique, which reconstructs missing data in the reciprocal image space, the so-called k-space. First, the application of GRAPPA for 3D imaging is desribed. In 3D imaging, it is advantageous for the reconstruction quality of PPA methods to perform the data reduction in two spatial dimensions. However, until now GRAPPA has been restricted to experiments with data reduction in only one dimension. Here, a combination of GRAPPA and SENSE is presented which allows one to utilize the benefits of two-dimensional data reduction for the GRAPPA technique. Furthermore, a reformulation of the GRAPPA reconstruction process as a matrix operation is presented. This formalism is refered to as the GRAPPA-Operator formalism and it allows one to shift a received signal in k-space in order to reconstruct missing data. Several properties and relationships between different shifts are described and resultant implications for 2D and 3D imaging are presented. In general, all conventional PPA methods work on the reconstruction side. Therefore,the image quality and thus the achievable scan time reduction can only be controlled by the choice of the array geometry. In multi-slice MRI, this dependency on the array geometry can be reduced by modifying the appearence of imaging artifacts during the data acquisition period. In this way, the decrease in SNR introduced by the reconstruction process can be minimized. This concept is entitled "Controlled Aliasing in Parallel Imaging Results In Higher Acceleratrion" (CAIPIRINHA), and in this thesis its application for dynamic cardiac imaging is described. In contrast to previous PPA techniques with two-fold acceleration, the image quality using the CAIPIRINHA approach is not significantly decreased compared with conventional experiments.
38

The use of charged aerosol detection for the analysis of excipients and active pharmaceutical ingredients / Die Verwendung des "Charged Aerosol Detectors" zur Analytik von Hilfs- und Wirkstoffen

Ilko, David January 2015 (has links) (PDF)
The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase. This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) “Validation of Analytical Proce-dures” and the “Technical Guide for the Elaboration of Monographs”. In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose. For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate. There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix. A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species (“fingerprinting”) and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found. The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted. / Der “Corona® charged aerosol detector” (CAD) ist ein aerosol-basierter Detektor, welcher 2002 von Dixon und Peterson vorgestellt wurde. Damit lassen sich nicht-flüchtige Substanzen unabhängig von ihren physiko-chemischen Eigenschaften detektieren. Daraus folgt, dass der CAD oft zur Analyse von Substanzen ohne UV-Chromophor angewandt wird. Großes Manko ist jedoch, dass das Signal nicht linear und abhängig vom Anteil organischen Lösemittels in der mobilen Phase ist. Ziel dieser Arbeit war es, mögliche Anwendungen des CAD in der pharmazeuti-schen Analytik zu erschließen. Dies wurde anhand von Beispielen aus unter-schiedlichen Substanzklassen untersucht. Dabei wurden neu entwickelte oder be-stehende Methoden validiert um die Leistung des CAD beurteilen zu können. So-wohl Gehaltsbestimmungen als auch Methoden zur Erfassung von Verunreinigun-gen wurden hinsichtlich ihrer Konformität mit dem Europäischen Arzneibuch (Ph. Eur.) geprüft. Im Zuge der Charakterisierung von Referenzsubstanzen beim EDQM wurde eine Methode zur Identifikation von pharmazeutischen Gegenionen benötigt. Zu diesem Zweck wurde eine HPLC-CAD-Methode von Zhang et al. hinsichtlich ihrer Eignung für das Ph. Eur. überprüft. Mit dieser Methode ließen sich 23 pharmazeutisch rele-vante Ionen trennen und detektieren. Die Ionen wurden durch Vergleich der Re-tentionszeiten eines Standards erreicht. Zusätzlich wurde die Peakzuordnung mit-tels der Bestimmung der Präzisionsmasse des Gegenions oder des Arzneistoffes durch ein TOF-MS durchgeführt. Die Methode ließ die Quantifizierung von Ionen als Verunreinigung oder zur Bestimmung der Stöchiometrie eines Salzes zu. Bei der Bestimmung von Verunreinigungen von Topiramat wurde ein Vergleich zwischen CAD und ELSD angestellt. Es zeigte sich, dass der CAD in den Punkten Wiederholbarkeit, Empfindlichkeit und Linearität überlegen war. Mit beiden Detekto-ren wurde eine ähnlich gute Richtigkeit erzielt. Durch das Auftreten von nicht re-produzierbaren Peaks, welche nach dem Hauptpeak im Chromatogramm der Testlö-sung auftraten, war die Anwendung des ELSD hier auszuschließen. Eine der Ver-unreinigungen, Topiramat Verunreinigung A (Diacetonid) lieferte kein bzw. ein ver-ringertes Signal in ELSD und CAD. Aufgrund des relativ hohen Dampfdrucks der Substanz wurde sie während des Detektionsvorgangs verdampft. Das Signal konn-te durch Zugabe von Acetonitril nach der Säule und durch eine Verringerung der Temperatur des Vernebler um das neunfache vergrößert werden. Da aber die Emp-findlichkeit für alle anderen Verunreinigungen dennoch um das tausendfache hö-her war, war eine Quantifizierung von Topiramat Verunreinigung A nicht möglich. Die HPLC-CAD Methode wurde zusätzlich als Gehaltsbestimmungsmethode für Topiramat validiert. Die Anwendung des CAD zur Analyse von Hilfsstoffen birgt großes Potenzial, da viele Substanzen nicht über ein Chromophor verfügen. Im Zuge dieser Arbeit wurde eine einfache und schnelle Methode zur Gehaltsbestimmung von Polidocanol (PD) entwickelt. Diese wurde als mögliche Methode für das Ph. Eur. validiert. Zusätzlich wurde die Methode zur Bestimmung der Freisetzung von PD aus einer pharmazeu-tischen Matrix verwendet. Es wurde eine Methode zur Bestimmung der Fettsäurezusammensetzung von Poly-sorbat 80 (PS80) entwickelt und validiert. Mittels CAD und Massenspektrometrie war es möglich zwei neue Fettsäuren in 16 Chargen von vier verschiedenen Herstellern zu identifizieren. Alle Chargen entsprachen den Anforderungen des Ph. Eur. Wei-terhin wurde die Zusammensetzung der einzelnen PS80-Spezies („fingerprinting“) sowie der Peroxidgehalt untersucht. Neben dieser chemischen Charakterisierung wurden auch funktionalitätsbezogene Eigenschaften (FRCs) bestimmt. Korrelatio-nen zwischen chemischen Zusammensetzung und FRCs wurden gefunden. Die Validierungsdaten der genannten Methoden legen nahe, dass der CAD sinn-voll zur pharmazeutischen Analytik angewendet werden kann. Für nicht-flüchtige Substanzen wurde stets eine ausreichende Empfindlichkeit erreicht. Somit können Verunreinigungen bis zu einer Konzentration von 0.05 bzw. 0.03%, wie von der ICH Richtlinie Q3A (R2) gefordert, quantifiziert werden. Jedoch kann das Detektorsignal bei halb-flüchtigen Substanzen stark erniedrigt sein. Es konnte bestätigt werden, dass sich das Detektorsignal über zwei Größenordnungen linear verhält. Abwei-chungen davon sind in Abhängigkeit der jeweiligen Methode möglich. Ist der Mess-bereich genügen klein, so kann ein Stoff mittels Einpunkt-Kalibrierung quantifiziert werden. Dieses Vorgehen sollte bei Gehaltsbestimmungen angewandt werden. Ebenfalls mittels Einpunkt-Kalibrierung können Verunreinigungen erfasst werden. Jedoch kann es notwendig sein, Korrekturfaktoren zu bestimmen. Die Richtigkeit ist hier deutlich niedriger als bei einer Gehaltsbestimmungsmethode. Über einen gro-ßen Konzentrationsbereich muss eine Ausgleichskurve mit log-log-Transformation verwendet werden. Die Richtigkeit ist hierbei ebenfalls geringer als bei einer Ge-haltsbestimmung.
39

Photoproduktion von p-1hn0w pi 0 omega] am Proton bei Energien bis zu 3 GeV Messungen mit dem Crystal-Barrel-Detektor an ELSA

Junkersfeld, Jörg Unknown Date (has links) (PDF)
Bonn, Univ., Diss., 2005
40

Photoproduktion von -1hn0w pi Messungen mit dem Crystal-Barrel-Detektor an ELSA /

Junkersfeld, Jörg. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2005--Bonn.

Page generated in 0.202 seconds