• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 5
  • 3
  • 1
  • 1
  • Tagged with
  • 31
  • 31
  • 20
  • 20
  • 19
  • 15
  • 15
  • 13
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Proteção diferencial adaptativa de transformadores de potência baseada na análise de componentes wavelets

Oliveira, Mario Orlando January 2013 (has links)
Este trabalho fundamenta-se no desenvolvimento e aprimoramento de uma metodologia de proteção diferencial de Transformadores de Potência. A metodologia desenvolvida avalia eventos transitórios que dificultam a operação correta de relés diferenciais aplicados à proteção de transformadores. O estudo concentra-se no estabelecimento de contribuições ao estado da arte associadas à análise de sinais de corrente diferenciais geradas tanto por faltas internas e externas quanto por distúrbios transitórios. A concepção da metodologia proposta baseou-se na quantificação da energia espectral gerada a través dos coeficientes de detalhe da Transformada Wavelet Discreta. A metodologia de proteção proposta foi desenvolvida em ambiente MATLAB® e testada por meio de simulações realizadas através do software ATP/EMTP (Alternative Transients Program/Electromagnetic Transients Program). Os resultados da pesquisa mostram a aplicabilidade do algoritmo de proteção, mesmo nas condições mais adversas, como na ocorrência da saturação dos transformadores de corrente. / This work is based on the development and improvement of a methodology to differential protection of power transformer. The proposed methodology evaluates transient events that difficult the correct operation of differential relays applied to transformer protection. The study establishes contributions to the state of the art related to differential current analysis generated by internal and external faults and transient disturbance. The conception of the proposed methodology was based on the spectral energies variation generated by each event and calculated through the detail coefficient of Discrete Wavelet Transform. The proposed methodology was developed in MATLAB® environment and tested through several simulations performed with the ATP/EMTP software (Alternative Transients Program / Electromagnetic Transients Program). The results of the research show the applicability of the protection algorithms, even in adverse conditions, such as saturation of current transformers.
12

Proteção diferencial de transformadores trifásicos utilizando a transformada wavelet

Oliveira, Mario Orlando January 2009 (has links)
A qualidade e a continuidade do fornecimento de energia elétrica aos consumidores são fatores muito importantes quando da avaliação da eficiência de um sistema elétrico de potência. Nesse contexto, os transformadores são equipamentos muito importantes e demandam especial atenção quando do projeto do esquema de proteção. Apesar do crescente desenvolvimento das metodologias de proteção de transformadores trifásicos, alguns aspectos ainda não foram totalmente solucionados. Um desses diz respeito à proteção diferencial de transformadores de potência, a qual apresenta vários problemas na discriminação de faltas internas ao transformador. A geração de correntes diferenciais provocada por fenômenos transitórios, como a energização do transformador, produz a incorreta operação do relé, ocasionando uma queda na eficiência do esquema de proteção diferencial. Assim sendo, o presente trabalho apresenta uma nova metodologia de proteção diferencial de transformadores trifásicos, a qual utiliza a transformada wavelet para extrair os sinais transitórios dominantes induzidos pelas faltas internas. A transformada wavelet é uma eficiente ferramenta utilizada no estudo de sinais não-estacionários e de rápida transição. De forma a atender os principais problemas do esquema convencional de proteção, a transformada wavelet discreta é utilizada para decompor os sinais de corrente diferencial em várias faixas de freqüências. Após essa decomposição, a variação de energia espectral dos coeficientes de detalhe wavelet é analisada pelo algoritmo proposto, e assim uma discriminação entre faltas internas e correntes de magnetização, ou correntes inrush, é feita. Usando um modelo elaborado de um sistema elétrico de transmissão são efetuadas rigorosas simulações computacionais para avaliar o desempenho do algoritmo proposto. Os resultados obtidos nessas simulações mostram que a metodologia de proteção diferencial de transformadores trifásicos baseada na variação de energia espectral dos coeficientes wavelets apresenta um ótimo desempenho quando comparada com a metodologia de proteção convencional. / Power supply quality and continuity are very important aspect when assessing the efficiency of an electric power system. In this context, the transformers are key equipments that require special attention during the protection scheme design. Despite the increasing development of methodologies for three-phase transformers protection, some aspects have not yet been fully studied. One of these aspects concerns to the differential protection of power transformers, which presents several restrictions regarding the characterization of internal faults. The observation of differential currents caused by transient phenomena such as transformer energization, produces an incorrect operation of protective relaying, causing a drop in the protection scheme efficiency. Therefore, this work presents a new methodology for differential protection of three-phase transformers using the wavelet transform to extract the transient signals induced by the dominant internal faults. The wavelet transform is an efficient tool in the study of non-stationary signals with fast transients. In order to overcome the main problems of the traditional protection scheme, the discrete wavelet transform is used to decompose the differential current signals into several bands of frequencies. After this decomposition, the spectral energy variation of the wavelet detail coefficients is analyzed by the proposed algorithm and, thus, classification between internal faults, external faults and inrush currents is performed. Using a transmission system model, accurate simulations are performed to evaluate the computational performance of the proposed protection algorithm. The results obtained in these simulations show that the proposed methodology has a great performance when compared with traditional protection philosophies.
13

Proteção diferencial adaptativa de transformadores de potência baseada na análise de componentes wavelets

Oliveira, Mario Orlando January 2013 (has links)
Este trabalho fundamenta-se no desenvolvimento e aprimoramento de uma metodologia de proteção diferencial de Transformadores de Potência. A metodologia desenvolvida avalia eventos transitórios que dificultam a operação correta de relés diferenciais aplicados à proteção de transformadores. O estudo concentra-se no estabelecimento de contribuições ao estado da arte associadas à análise de sinais de corrente diferenciais geradas tanto por faltas internas e externas quanto por distúrbios transitórios. A concepção da metodologia proposta baseou-se na quantificação da energia espectral gerada a través dos coeficientes de detalhe da Transformada Wavelet Discreta. A metodologia de proteção proposta foi desenvolvida em ambiente MATLAB® e testada por meio de simulações realizadas através do software ATP/EMTP (Alternative Transients Program/Electromagnetic Transients Program). Os resultados da pesquisa mostram a aplicabilidade do algoritmo de proteção, mesmo nas condições mais adversas, como na ocorrência da saturação dos transformadores de corrente. / This work is based on the development and improvement of a methodology to differential protection of power transformer. The proposed methodology evaluates transient events that difficult the correct operation of differential relays applied to transformer protection. The study establishes contributions to the state of the art related to differential current analysis generated by internal and external faults and transient disturbance. The conception of the proposed methodology was based on the spectral energies variation generated by each event and calculated through the detail coefficient of Discrete Wavelet Transform. The proposed methodology was developed in MATLAB® environment and tested through several simulations performed with the ATP/EMTP software (Alternative Transients Program / Electromagnetic Transients Program). The results of the research show the applicability of the protection algorithms, even in adverse conditions, such as saturation of current transformers.
14

Proposta de um algoritmo eficiente para a localização de faltas por relé diferencial numérico para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC) /

Taquire, Nelson Romero January 2016 (has links)
Orientador: Jose Sanches Mantovani / Resumo: Neste trabalho propõe-se um método para a localização de faltas que, em conjunto com a lógica de um relé diferencial numérico, deve ser usado para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC). Este método visa solucionar o problema de localização de faltas melhorando a precisão dos algoritmos que utilizam medições de sinais de tensão e corrente numa terminação da linha de transmissão. O cálculo da distância entre a terminação da linha de transmissão e o ponto de incidência da falta é realizado utilizando dois procedimentos: um para faltas produzida no trecho entre a terminação local da linha de transmissão e o TCSC; e o outro para faltas no trecho entre o TCSC e a terminação remota. A detecção do trecho de incidência da falta é obtido usando as medições de escorregamento angular dos sinais de corrente em ambos os extremos da linha de transmissão e a medição da resistência de falta no extremo local, que é variável durante o intervalo de início até um ciclo depois da ocorrência da falta. A aplicação da lógica difusa na comparação destas medições permite detectar com precisão o trecho com falta. O método proposto foi testado usando um sistema teste da literatura onde múltiplos casos de faltas em diferentes pontos da linha de transmissão foram simulados. Os resultados mostram a capacidade do algoritmo em localizar precisamente a posição de ocorrência da falta. / Abstract: This paper proposes a methodology for locating faults in transmission lines with thyristor-controlled series compensation (TCSC) that are protected by numerical differential relays. The proposed methodology aims to overcome problems of fault location improving the accuracy of algorithms that use voltage and current measurement signals from a transmission line termination. The calculation of the distance between the transmission line termination and the fault incidence point employs two procedures: one for faults in the transmission line section limited by the local termination and TCSC; and other for faults in the section limited by the TCSC and remote termination. The detection of the fault incidence section is achieved using measurements of angular deviation for both transmission line terminations and the measurement of fault resistance in the local termination, which varies during the interval from the beginning to one cycle after the fault occurrence. The use of fuzzy logic for comparing these measurements permits the accurate detection of the fault incidence section. The proposed method is tested using a test system from literature system where multiple fault cases in different positions of the transmission line are simulated. The results show the algorithm capability to locate accurately the position of fault occurrence. / Mestre
15

Relé diferencial para transformadores de potência utilizando ferramentas inteligentes / A differential relay for power transformers using intelligent tools

Segatto, Ênio Carlos 12 April 2005 (has links)
Este trabalho apresenta a proposta de um sistema completo de proteção diferencial de transformadores de potência, aplicando-se as técnicas de Redes Neurais Artificiais (RNAs). O esquema proposto busca a classificação do sistema de proteção como um problema de reconhecimento e reconstrução de padrões, representando um método alternativo aos algoritmos convencionais. Vários fatores como, por exemplo, as situações de energização do transformador e a saturação dos transformadores de corrente, podem causar uma má operação do dispositivo de proteção. Com o objetivo de melhoramento na proteção digital de transformadores de potência, desenvolveu-se um sistema de proteção diferencial, incluindo dispositivos com base em RNAs, em substituição à filtragem harmônica de sinais existente no algoritmo convencional. Em complementação, esquemas de reconstrução das ondas distorcidas provenientes da saturação dos TCs são também propostos e adicionados ao algoritmo final de proteção, sendo esses comparados ao algoritmo convencional de proteção diferencial de transformadores. Com a referida adição de ferramentas de inteligência artificial a um algoritmo completo de proteção diferencial de transformadores, obteve-se uma solução bastante precisa e eficiente, capaz de responder em um tempo reduzido, se comparada aos métodos convencionais. / This work proposes a complete differential protection system for power transformers, applying the Artificial Neural Network (ANN) theory. The proposed approach treat the classification of the protection system as a problem of pattern recognition and as an alternative method to the conventional algorithms. Several factors such as, for example, transformer energization and CT saturation can cause an inadequate operation of the protection relay. With the objective of improving the power transformer digital protection, a complete protection system was developed, including an ANN-based device in substitution to harmonic filters, in use in the conventional algorithm. Some approaches concerning the reconstruction of the distorted signals caused by the CTs saturation are also proposed. These routines are added to the final protection algorithm and they are compared to the conventional algorithm for power transformer protection. With the use of artificial intelligence tools in a complete power transformer protection algorithm, one intends to obtain a very precise, fast and efficient solution, if compared to the conventional methods.
16

Projeto diferencial de geradores síncronos: o uso de redes neurais artificiais para identificação e correção da saturação dos transformadores de corrente / Differential protection for synchronous generators: the use of artificial neural networks for identification and correction of the saturation of current transformers.

Silva, Rogério Cesar Serapião 09 March 2012 (has links)
Este trabalho tem como objetivo apresentar um algoritmo de proteção diferencial de geradores baseado em Redes Neurais Artificiais (RNAs), que seja robusto e confiável em situações onde os algoritmos padrões podem apresentar dificuldades, como no caso, da saturação de TCs. O algoritmo desenvolvido é constituído por dois módulos principais: a) um módulo de detecção da saturação dos transformadores de corrente (TCs) empregados na proteção diferencial de geradores e; b) um módulo de correção das formas de onda distorcidas devido à saturação dos TCs. Os módulos utilizam RNAs para detectar e corrigir situações onde haja saturação dos TCs, a fim de evitar a má operação da proteção diferencial. O algoritmo foi desenvolvido em ambiente Matlab e validado com base nos dados da modelagem e simulações de um sistema elétrico utilizando o software Alternative Transients Program (ATP). / This work has as objective to present an algorithm for differential protection of generators based on Artificial Neural Networks (ANN), which is robust and reliable in situations where standard algorithms fail, as in the case of Current Transformer (CT) saturation. The algorithm developed consists of two main modules: a) a module to detect saturation of CTs used in differential protection of generators and; b) module to correct distorted waveforms due to CT saturation. The modules use ANNs to detect and correct situations where there is saturation of CTs in order to avoid misoperation of the differential protection. The algorithm was developed using Matlab software and validated based on data modeling and simulations of a power system using the Alternative Transients Program (ATP) software.
17

Um esquema completo de proteção diferencial de transformadores para testes em um relé digital / A complete model of differential protection of transformers for tests in a digital relay

Bernardes, Alexandre Paciencia 25 April 2006 (has links)
Este trabalho apresenta um procedimento completo de simulação da proteção digital diferencial aplicada a transformadores de potência, visando o emprego deste à avaliação do comportamento de relés comercialmente disponíveis. Foi escolhido o software ATP (Alternative Transients Program) como ferramenta para a simulação de distintas situações sobre um sistema diferencial de proteção aplicado a um transformador de 25 MVA. Dentre as ocorrências evidenciadas, destacam-se: situações de faltas internas, faltas externas, situações de energização e energização com falta interna do transformador, condição de sobreexcitação e de saturação de TC (Transformador de Corrente). Cabe comentar que das simulações a real caracterização sobre o relé em teste, fez-se necessário todo um pré-processamento e análise da informação que será convenientemente abordada e justificada no trabalho apresentado, denotando-se um procedimento comum de teste a ser adotado a esta filosofia de proteção. A metodologia e esquema prático adotado trazem uma contribuição importante para a análise laboratorial de modelagens e simulações aplicadas a relés de proteção presentes no mercado e contribui de maneira substancial para os estudos teóricos de possíveis soluções para limitações eventualmente encontradas / This dissertation presents a complete procedure of simulation of digital differential protection applied to power transformers, focusing on its use to evaluate of the behavior of commercially available relays. Software ATP (Alternative Transients Program) was chosen as a tool for the simulation of distinct situations in a differential protection system applied to a 25 MVA three-phase transformer. Amongst the evidenced occurrences internal and external fault conditions, energization with or without internal fault of a three-phase transformer, overexcitation and CT (Current Transformer) saturation conditions were distinguished. It should be mentioned that from simulations to the characterization the real situations on the relay in test, a pre-processing and analysis of the information were necessary, and will be justified in the present study, denoting a common test procedure to be adopted to this philosophy of protection
18

Projeto diferencial de geradores síncronos: o uso de redes neurais artificiais para identificação e correção da saturação dos transformadores de corrente / Differential protection for synchronous generators: the use of artificial neural networks for identification and correction of the saturation of current transformers.

Rogério Cesar Serapião Silva 09 March 2012 (has links)
Este trabalho tem como objetivo apresentar um algoritmo de proteção diferencial de geradores baseado em Redes Neurais Artificiais (RNAs), que seja robusto e confiável em situações onde os algoritmos padrões podem apresentar dificuldades, como no caso, da saturação de TCs. O algoritmo desenvolvido é constituído por dois módulos principais: a) um módulo de detecção da saturação dos transformadores de corrente (TCs) empregados na proteção diferencial de geradores e; b) um módulo de correção das formas de onda distorcidas devido à saturação dos TCs. Os módulos utilizam RNAs para detectar e corrigir situações onde haja saturação dos TCs, a fim de evitar a má operação da proteção diferencial. O algoritmo foi desenvolvido em ambiente Matlab e validado com base nos dados da modelagem e simulações de um sistema elétrico utilizando o software Alternative Transients Program (ATP). / This work has as objective to present an algorithm for differential protection of generators based on Artificial Neural Networks (ANN), which is robust and reliable in situations where standard algorithms fail, as in the case of Current Transformer (CT) saturation. The algorithm developed consists of two main modules: a) a module to detect saturation of CTs used in differential protection of generators and; b) module to correct distorted waveforms due to CT saturation. The modules use ANNs to detect and correct situations where there is saturation of CTs in order to avoid misoperation of the differential protection. The algorithm was developed using Matlab software and validated based on data modeling and simulations of a power system using the Alternative Transients Program (ATP) software.
19

Um esquema completo de proteção diferencial de transformadores para testes em um relé digital / A complete model of differential protection of transformers for tests in a digital relay

Alexandre Paciencia Bernardes 25 April 2006 (has links)
Este trabalho apresenta um procedimento completo de simulação da proteção digital diferencial aplicada a transformadores de potência, visando o emprego deste à avaliação do comportamento de relés comercialmente disponíveis. Foi escolhido o software ATP (Alternative Transients Program) como ferramenta para a simulação de distintas situações sobre um sistema diferencial de proteção aplicado a um transformador de 25 MVA. Dentre as ocorrências evidenciadas, destacam-se: situações de faltas internas, faltas externas, situações de energização e energização com falta interna do transformador, condição de sobreexcitação e de saturação de TC (Transformador de Corrente). Cabe comentar que das simulações a real caracterização sobre o relé em teste, fez-se necessário todo um pré-processamento e análise da informação que será convenientemente abordada e justificada no trabalho apresentado, denotando-se um procedimento comum de teste a ser adotado a esta filosofia de proteção. A metodologia e esquema prático adotado trazem uma contribuição importante para a análise laboratorial de modelagens e simulações aplicadas a relés de proteção presentes no mercado e contribui de maneira substancial para os estudos teóricos de possíveis soluções para limitações eventualmente encontradas / This dissertation presents a complete procedure of simulation of digital differential protection applied to power transformers, focusing on its use to evaluate of the behavior of commercially available relays. Software ATP (Alternative Transients Program) was chosen as a tool for the simulation of distinct situations in a differential protection system applied to a 25 MVA three-phase transformer. Amongst the evidenced occurrences internal and external fault conditions, energization with or without internal fault of a three-phase transformer, overexcitation and CT (Current Transformer) saturation conditions were distinguished. It should be mentioned that from simulations to the characterization the real situations on the relay in test, a pre-processing and analysis of the information were necessary, and will be justified in the present study, denoting a common test procedure to be adopted to this philosophy of protection
20

Proposta de um algoritmo eficiente para a localização de faltas por relé diferencial numérico para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC) / Propuesta de un algoritmo eficiente para la localización de fallas por réle diferencial numérico para protección de lineas de transmisión con compensacion serie controlada por tiristores (TCSC)

Taquire, Nelson Romero [UNESP] 21 March 2016 (has links)
Submitted by NELSON GIOVANNY ROMERO TAQUIRE (romero.taquire.nelson@gmail.com) on 2016-05-20T21:35:24Z No. of bitstreams: 1 NelsonGiovannyRomeroTaquire2016.pdf: 3534022 bytes, checksum: 59ecb7956af007830fd18b15c10562c2 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-24T13:42:19Z (GMT) No. of bitstreams: 1 taquire_ngr_me_ilha.pdf: 3534022 bytes, checksum: 59ecb7956af007830fd18b15c10562c2 (MD5) / Made available in DSpace on 2016-05-24T13:42:19Z (GMT). No. of bitstreams: 1 taquire_ngr_me_ilha.pdf: 3534022 bytes, checksum: 59ecb7956af007830fd18b15c10562c2 (MD5) Previous issue date: 2016-03-21 / Fundação de Ensino, Pesquisa e Extensão de Ilha Solteira (FEPISA) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho propõe-se um método para a localização de faltas que, em conjunto com a lógica de um relé diferencial numérico, deve ser usado para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC). Este método visa solucionar o problema de localização de faltas melhorando a precisão dos algoritmos que utilizam medições de sinais de tensão e corrente numa terminação da linha de transmissão. O cálculo da distância entre a terminação da linha de transmissão e o ponto de incidência da falta é realizado utilizando dois procedimentos: um para faltas produzida no trecho entre a terminação local da linha de transmissão e o TCSC; e o outro para faltas no trecho entre o TCSC e a terminação remota. A detecção do trecho de incidência da falta é obtido usando as medições de escorregamento angular dos sinais de corrente em ambos os extremos da linha de transmissão e a medição da resistência de falta no extremo local, que é variável durante o intervalo de início até um ciclo depois da ocorrência da falta. A aplicação da lógica difusa na comparação destas medições permite detectar com precisão o trecho com falta. O método proposto foi testado usando um sistema teste da literatura onde múltiplos casos de faltas em diferentes pontos da linha de transmissão foram simulados. Os resultados mostram a capacidade do algoritmo em localizar precisamente a posição de ocorrência da falta. / This paper proposes a methodology for locating faults in transmission lines with thyristor-controlled series compensation (TCSC) that are protected by numerical differential relays. The proposed methodology aims to overcome problems of fault location improving the accuracy of algorithms that use voltage and current measurement signals from a transmission line termination. The calculation of the distance between the transmission line termination and the fault incidence point employs two procedures: one for faults in the transmission line section limited by the local termination and TCSC; and other for faults in the section limited by the TCSC and remote termination. The detection of the fault incidence section is achieved using measurements of angular deviation for both transmission line terminations and the measurement of fault resistance in the local termination, which varies during the interval from the beginning to one cycle after the fault occurrence. The use of fuzzy logic for comparing these measurements permits the accurate detection of the fault incidence section. The proposed method is tested using a test system from literature system where multiple fault cases in different positions of the transmission line are simulated. The results show the algorithm capability to locate accurately the position of fault occurrence.

Page generated in 0.1075 seconds