• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 14
  • 14
  • 10
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição para Inserção Controlada de Capacitores na Distribuição Secundária

AZEREDO, G. F. 09 December 2009 (has links)
Made available in DSpace on 2018-08-02T00:00:48Z (GMT). No. of bitstreams: 1 tese_2862_Dissertação - Final - Giovani Freire 2009.pdf: 1202991 bytes, checksum: a9c803d2a3f82ff6e07dc74e09be0dec (MD5) Previous issue date: 2009-12-09 / Este trabalho apresenta uma rotina de cálculo para suporte à escolha, na distribuição secundária, do poste (ou conexão equivalente) em que capacitores são inseridos / removidos de forma discreta para controle da tensão de fase. A abordagem de análise da tensão em cada poste para várias situações de carregamento é apresentada, bem como a análise de ganho de tensão através da inserção discreta de capacitores. Também é realizada análise de sensibilidade a harmônicos de tensão e de corrente de carga. Uma implementação em ambiente MATLAB é apresentada, com a análise de algumas situações para verificação da proposta. Os resultados mostram a utilidade do algoritmo desenvolvido.
2

Análise da Correção de Tensão em Circuitos Secundários de BT em Anel Usando Capacitores

LUCHINI, O. M. 27 May 2011 (has links)
Made available in DSpace on 2016-08-29T15:32:30Z (GMT). No. of bitstreams: 1 tese_2760_DissertacaoMestradoOctavioMatosLuchini.pdf: 2299108 bytes, checksum: b132aaaa9bb8452d439d858a4f5aaae2 (MD5) Previous issue date: 2011-05-27 / Neste trabalho é feito um estudo do melhor ponto de alocação de bancos de capacitores em redes de distribuição secundária em anel visando à melhoria das tensões de fornecimento a níveis adequados para consumo. Primeiramente, são apresentadas as principais características da distribuição secundária, com ênfase na topologia anel, e da qualidade da energia envolvida. Depois, são discutidos os principais métodos de cálculo de queda de tensão na rede e apresentado o desenvolvimento de um método sem simplificações, que permite traçar o perfil de tensão ao longo do alimentador antes e após a inserção dos bancos, para avaliar o melhor ponto de alocação. São apresentados também o algoritmo de cálculo implementado, a modelagem matemática dos componentes do sistema e as considerações que foram feitas de acordo com o ponto de conexão escolhido. O impacto da inserção dos bancos de capacitores na amplificação de harmônicos de tensão também é discutido com as devidas considerações e modelagem matemática para determinada frequência harmônica. São apresentados resultados de simulação computacional do algoritmo implementado para determinadas redes em diferentes níveis de carregamento que demonstram a aplicabilidade do método na análise da inserção de reativos capacitivos na rede e na avaliação da amplificação de harmônicos de tensão causada pela conexão dos bancos.
3

Estimação dos parâmetros de linha de transmissão a partir de um segmento de linha discretizado /

Utida, Mariza Akiko. January 2007 (has links)
Orientador: Sérgio Kurokawa / Banca: Dalgerti Lelis Milanese / Banca: Afonso José do Prado / Resumo: Neste trabalho é proposta uma metodologia para obter parâmetros de linha de transmissão a partir da corrente e da tensão de fase obtida em dois pontos consecutivos da linha. O cálculo dos parâmetros da linha de transmissão consiste em determinar as correntes e tensões no domínio de fase e obter a impedância e admitância no domínio de fase. Propõe-se para esse cálculo a utilização do método de decomposição modal, que desacopla uma linha polifásica de n fases em n modos. A vantagem do uso da decomposição modal está na redução da quantidade de elementos complexos da matriz de transformação. Para a solução da decomposição modal foram utilizados a matriz de transformação modal [TI], sendo obtida através do método de Newton-Raphson, e a matriz de Clarke para calcular a impedância longitudinal e admitância transversal da linha em um circuito p . Foi utilizada uma linha trifásica não transposta com plano de simetria vertical de 440 kV e freqüências compreendidas entre 10 Hz e 1 MHz. Desse modo, é feita uma comparação entre os resultados obtidos com a metodologia desenvolvida, calculados a partir das correntes e tensões de fase da linha transmissão de um circuito p utilizando a matriz de Clarke, e a metodologia clássica, que utiliza as equações de Carson e Bessel, as quais levam em consideração o efeito do solo e o efeito pelicular. / Abstract: In this paper, it is proposed a methodology to obtain parameters of transmission lines from phase currents and voltages obtained in two consecutives points of the lines. The estimation of the parameters of transmissions lines aims to determine the current and voltage in phase domain, as well as, to determine the impedance and admittance in phase domain. It proposes the utilization of the modal decomposition method that decouples a n-phase line of in n modes. The advantage of using modal decomposition is the reduction of the amount of the complex elements in the transformation matrix. To obtain the solution of modal decomposition, it was used a modal transformation matrix [TI] obtained through of Newton-Raphson method and Clarke's matrix that estimates longitudinal impedance and transversal admittance of a line on a p circuit arrangement. It was used an untransposed three-phase line with a vertical symmetry plane of 440 kV and frequencies between 10 Hz and 1 MHz. It is done a comparison between the results obtained with the developed methodology estimated from current and voltage of a transmission line of a p circuit using Clarke's matrix, and calculated by classic methodology that uses Carson and Bessel equations which consider ground and skin effects. / Mestre
4

Representação modal alternativa de linhas de transmissão trifásicas simétricas não idealmente transpostas /

Daltin, Rodrigo Serra. January 2006 (has links)
Orientador: Sérgio Kurokawa / Banca: Luiz Fernando Bovolato / Banca: Afonso José do Prado / Resumo: Esta dissertação descreve um processo alternativo para decompor uma linha de transmissão trifásica, simétrica e não transposta nos seus modos exatos por meio da utilização de duas matrizes de transformação. A primeira é a matriz de Clarke que desacopla a linha em suas componentes a, ß e zero. A componente ß é um modo exato enquanto que as componentes a e zero são acopladas. Em seguida, as componentes a e zero são representadas por uma linha bifásica que pode ser decomposta em seus modos exatos por meio de uma matriz de transformação adequada, cujos elementos podem ser sintetizados, no domínio do tempo, por técnicas de aproximações por curvas. O método pretende unir as vantagens da matriz de transformação exata (que produz modos exatos) com as vantagens da matriz de Clarke, que é real, independente da freqüência e facilmente representável em programas que realizam simulações de transitórios, como é o caso do EMTP. Assim, o método pode ser utilizado em situações em que o acoplamento entre as componentes a e zero não possa ser desconsiderado. O processo foi utilizado para simular a energização de uma linha trifásica, sem transposição, com um plano de simetria vertical, 440 kV e comprimento de 500 km que foi representada no domínio modal por meio do método proposto e também por meio do uso da matriz de autovetores (como sendo a matriz de decomposição modal). O método é coerente, pois foram obtidos resultados semelhantes com os dois métodos de decomposição modal, enquanto que com o uso somente da matriz de Clarke, verificou- se certa diferença em relação aos valores esperados. / Abstract: This dissertation describes an alternative procedure to decompose a non-transposed threephase transmission line into exact modes, by using two transformation matrices. The first one is Clarke's matrix, which separates the line into quasi-modes a, ß e zero. The ß component is an exact mode while a and zero are coupled. After that, the coupled components are represented by using a two-phase transmission line without a vertical symmetry plane that can be decomposed with a modal transformation matrix whose elements can be achieved, in timedomain, through standard curve-fitting techniques. The method intends to join the Clarke's matrix advantages which crucial aspect is being real, frequency-independent and easily represented in computational transient programs (EMTP) with eigenvector's matrix used in situations where the coupling between a and zero components cannot be disconsidered. The process was used to energize a three-phase transmission line with a vertical symmetry plane, which nominal voltage is 440kV and its length, 500km. It was represented in the modal domain by considered method and, on the other hand, by using eigenvector's matrix (as being the decomposition matrix). In fact, the obtained results had shown that the method is coherent, because it is obtained similar results with the application of the two mentioned modal decomposition methods, whereas with the use of Clarke's matrix, a perceptible difference in relation to the expected values was verified. / Mestre
5

Contribuições para um projeto mais sustentável de redes de distribuição de baixa tensão

Seabra, Pedro Miguel da Costa January 2013 (has links)
Tese de Mestrado Integrado. Engenharia Eletrotécnica e de Computadores (Energia). Faculdade de Engenharia. Universidade do Porto. 2013
6

Representação modal alternativa de linhas de transmissão trifásicas simétricas não idealmente transpostas

Daltin, Rodrigo Serra [UNESP] 28 September 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-09-28Bitstream added on 2014-06-13T19:08:14Z : No. of bitstreams: 1 daltin_rs_me_ilha.pdf: 841004 bytes, checksum: da77f2e8d8ccd4d0094ea607844c7530 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta dissertação descreve um processo alternativo para decompor uma linha de transmissão trifásica, simétrica e não transposta nos seus modos exatos por meio da utilização de duas matrizes de transformação. A primeira é a matriz de Clarke que desacopla a linha em suas componentes a, ß e zero. A componente ß é um modo exato enquanto que as componentes a e zero são acopladas. Em seguida, as componentes a e zero são representadas por uma linha bifásica que pode ser decomposta em seus modos exatos por meio de uma matriz de transformação adequada, cujos elementos podem ser sintetizados, no domínio do tempo, por técnicas de aproximações por curvas. O método pretende unir as vantagens da matriz de transformação exata (que produz modos exatos) com as vantagens da matriz de Clarke, que é real, independente da freqüência e facilmente representável em programas que realizam simulações de transitórios, como é o caso do EMTP. Assim, o método pode ser utilizado em situações em que o acoplamento entre as componentes a e zero não possa ser desconsiderado. O processo foi utilizado para simular a energização de uma linha trifásica, sem transposição, com um plano de simetria vertical, 440 kV e comprimento de 500 km que foi representada no domínio modal por meio do método proposto e também por meio do uso da matriz de autovetores (como sendo a matriz de decomposição modal). O método é coerente, pois foram obtidos resultados semelhantes com os dois métodos de decomposição modal, enquanto que com o uso somente da matriz de Clarke, verificou- se certa diferença em relação aos valores esperados. / This dissertation describes an alternative procedure to decompose a non-transposed threephase transmission line into exact modes, by using two transformation matrices. The first one is Clarke's matrix, which separates the line into quasi-modes a, ß e zero. The ß component is an exact mode while a and zero are coupled. After that, the coupled components are represented by using a two-phase transmission line without a vertical symmetry plane that can be decomposed with a modal transformation matrix whose elements can be achieved, in timedomain, through standard curve-fitting techniques. The method intends to join the Clarke's matrix advantages which crucial aspect is being real, frequency-independent and easily represented in computational transient programs (EMTP) with eigenvector's matrix used in situations where the coupling between a and zero components cannot be disconsidered. The process was used to energize a three-phase transmission line with a vertical symmetry plane, which nominal voltage is 440kV and its length, 500km. It was represented in the modal domain by considered method and, on the other hand, by using eigenvector's matrix (as being the decomposition matrix). In fact, the obtained results had shown that the method is coherent, because it is obtained similar results with the application of the two mentioned modal decomposition methods, whereas with the use of Clarke's matrix, a perceptible difference in relation to the expected values was verified.
7

Estimação dos parâmetros de linha de transmissão a partir de um segmento de linha discretizado

Utida, Mariza Akiko [UNESP] 02 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-02Bitstream added on 2014-06-13T19:28:10Z : No. of bitstreams: 1 utida_ma_me_ilha.pdf: 904352 bytes, checksum: 752f1ee472f9c7246beb1651b7b2e820 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho é proposta uma metodologia para obter parâmetros de linha de transmissão a partir da corrente e da tensão de fase obtida em dois pontos consecutivos da linha. O cálculo dos parâmetros da linha de transmissão consiste em determinar as correntes e tensões no domínio de fase e obter a impedância e admitância no domínio de fase. Propõe-se para esse cálculo a utilização do método de decomposição modal, que desacopla uma linha polifásica de n fases em n modos. A vantagem do uso da decomposição modal está na redução da quantidade de elementos complexos da matriz de transformação. Para a solução da decomposição modal foram utilizados a matriz de transformação modal [TI], sendo obtida através do método de Newton-Raphson, e a matriz de Clarke para calcular a impedância longitudinal e admitância transversal da linha em um circuito p . Foi utilizada uma linha trifásica não transposta com plano de simetria vertical de 440 kV e freqüências compreendidas entre 10 Hz e 1 MHz. Desse modo, é feita uma comparação entre os resultados obtidos com a metodologia desenvolvida, calculados a partir das correntes e tensões de fase da linha transmissão de um circuito p utilizando a matriz de Clarke, e a metodologia clássica, que utiliza as equações de Carson e Bessel, as quais levam em consideração o efeito do solo e o efeito pelicular. / In this paper, it is proposed a methodology to obtain parameters of transmission lines from phase currents and voltages obtained in two consecutives points of the lines. The estimation of the parameters of transmissions lines aims to determine the current and voltage in phase domain, as well as, to determine the impedance and admittance in phase domain. It proposes the utilization of the modal decomposition method that decouples a n-phase line of in n modes. The advantage of using modal decomposition is the reduction of the amount of the complex elements in the transformation matrix. To obtain the solution of modal decomposition, it was used a modal transformation matrix [TI] obtained through of Newton-Raphson method and Clarke's matrix that estimates longitudinal impedance and transversal admittance of a line on a p circuit arrangement. It was used an untransposed three-phase line with a vertical symmetry plane of 440 kV and frequencies between 10 Hz and 1 MHz. It is done a comparison between the results obtained with the developed methodology estimated from current and voltage of a transmission line of a p circuit using Clarke's matrix, and calculated by classic methodology that uses Carson and Bessel equations which consider ground and skin effects.
8

Redução do nível de curto circuito em redes de subtransmissão utilizando reatores com núcleo de ar / Application of air core reactors for reducing the short circuit level of subtransmission networks

Cardoso, Fredner Leandro, 1976- 26 August 2018 (has links)
Orientador: Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T06:55:21Z (GMT). No. of bitstreams: 1 Cardoso_FrednerLeandro_M.pdf: 3528656 bytes, checksum: b6121b44e4520a59d20be1f12ed3f377 (MD5) Previous issue date: 2014 / Resumo: Esta dissertação apresenta um estudo referente à instalação de reatores limitadores das correntes de curto circuito em redes de subtransmissão. O objetivo é adiar ou evitar a substituição de grandes quantidades de disjuntores e demais equipamentos por motivo de superação de capacidade interruptiva. O sistema em análise consiste da rede da CPFL de 138 kV, responsável pelo suprimento de energia elétrica à região metropolitana de Campinas, no interior do estado de São Paulo. Esta região é uma das mais dinâmicas no cenário econômico brasileiro e representa 1,8% do PIB (Produto Interno Bruto) nacional e 11,45% do PIB paulista, ou seja, cerca de 91,8 bilhões de reais. Além de possuir uma forte economia, a região também apresenta uma infraestrutura que proporciona o desenvolvimento de toda a área metropolitana. O cenário acima resulta em uma rede elétrica em expansão contínua, levando à elevação gradativa dos níveis de curto circuito. Com a previsão de superação da capacidade interruptiva em diversos módulos de manobra, as empresas concessionárias que atuam nessa região precisaram elaborar esquemas provisórios de operação de suas instalações de forma radializada, através da abertura de linhas e barramentos. Este trabalho analisa a viabilidade da solução deste problema através da instalação de dispositivos limitadores de curto circuito em determinados locais do sistema, especificamente reatores com núcleo de ar. Os resultados apresentados servirão como referência para tomada de decisão quanto a proceder ou não com as substituições originalmente planejadas. Um estudo sobre os efeitos colaterais resultados da instalação dos reatores também é apresentado, de forma a garantir que a solução sugerida não resulte em transgressão de outros critérios técnicos, tais como violação do perfil de tensão e carregamento em regime permanente e dos limites de tensão de restabelecimento transitória / Abstract: This master thesis presents a study on the application of limiting reactors for reducing the short circuit level of sub-transmission networks. The objective is to postpone or avoid the replacement of large amount of circuit breakers and other equipment due to the overcoming of their interruptive capacity. The system under consideration consists of the 138 kV CPFL network, responsible for supplying electricity to the metropolitan region of Campinas, in the state of São Paulo. This region presents a very dynamic economic scenario in Brazil, and represents 1,8% of national GDP about 91,8 billion Reais (Gross Domestic Product) and 11,45% of GDP of the São Paulo State. Besides having a strong economy, the region also maintains an infrastructure that provides the development of the entire metropolitan area. The above scenario results in an electric grid on continuous expansion, leading to progressive increase of the short circuit level on several buses of the network. Following the projection of interruptive capacity overcoming of several maneuver elements, the distribution utilities in this region were requested to elaborate operation schemes for their sub-transmission networks in order to accommodate the new situation. Such schemes leaded to temporary radial operation by opening sub-transmission lines and bus bars. This research work evaluate the viability of solving this problem by installing limiting devices for the short circuit levels, specifically air core reactors, in pre-determined sites of the system. The obtained results are useful as a reference for the decision making as to proceed or not with the originally planned replacements. A study on the side effects resulting from the installation of the reactors is also presented, in such a way to guarantee that the suggested solution does not result in violations of other technical criteria, such as steady state voltage end load violations or transient voltage recovery violations / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
9

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

López, Camilo Andrés Villabona 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
10

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

Camilo Andrés Villabona López 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.

Page generated in 0.143 seconds