31

Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneos

Herrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
32

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Celso Pereira Braz 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.