Σφάλματα στο δίκτυο μέσης τάσης νήσου Κρήτης

Ζήσης, Βασίλειος 31 August 2012 (has links)
Ο σκοπός αυτής της διπλωματικής εργασίας ήταν η μελέτη και η καταγραφή των σφαλμάτων που έχουν προκληθεί από ποικίλες αιτίες στο Δίκτυο Διανομής (Μέση Τάση) της Ηλεκτρικής Ενέργειας της νήσου Κρήτης και πιο συγκεκριμένα στο εναέριο δίκτυο αυτού. Για την κατανόηση όμως του λόγου που οι εν λόγω αιτίες οδήγησαν σε σφάλματα, αλλά και για να έχουμε μια πιο πλήρη εικόνα επί του αντικειμένου, έπρεπε αρχικά να γίνει μια συνοπτική παρουσίαση ενός τυπικού συστήματος ηλεκτρικής ενέργειας, αφού πρώτα αναλυθεί στα επιμέρους τμήματά του. Εν συνεχεία αναλύουμε λεπτομερώς την διαμόρφωση των δικτύων διανομής και τον βασικό εξοπλισμό από τον οποίο αποτελείται. Ακολούθως μελετούμε τα εναέρια δίκτυα διανομής μέσης τάσης παρουσιάζοντας πλήρως όλα τα στοιχεία που συμβάλλουν στην ομαλή διανομή της ηλεκτρικής ενέργειας στον καταναλωτή. Στο επόμενο βήμα παρουσιάζουμε την IEEE οδηγία για τη συμπεριφορά έναντι κεραυνών των εναέριων γραμμών διανομής ηλεκτρικής ενέργειας, μιας και οι επικρατούντες κλιματολογικές - περιβαλλοντολογικές συνθήκες είναι από τις βασικές αιτίες πρόκλησης σφαλμάτων στα εναέρια δίκτυα. Τέλος, παρουσιάζουμε τα σφάλματα που έχουν καταγραφεί στα ημερήσια δελτία σημαντικών μη προγραμματισμένων διακοπών της νήσου Κρήτης για τα έτη από το 2005 έως το 2009. / The aim of this diploma thesis was the examination and comprehension of the aerial distribution networks of electrical power. In the beginning we briefly analyzed the electric power systems (power stations, transmission networks, distribution networks). After that we thoroughly examined the configuration of the distribution networks with the observation of the ways the networks are planned and their equipment, which is used for their protection and for the connection between them. Afterwards we examined the aerial distribution networks of medium voltage, by fully presenting all the elements which contribute in the normal distribution of the electric flow to the customers. Finally we present the faults that have happened to the middle voltage distribution circuit of the island Crete and we compare them with the theoretical number of faults, according the IEEE guide in order to come to some useful conclusions.
22

Metodologia para proteção adaptativa de linhas de distribuição na presença de geradores síncronos distribuídos

Ferreira, Roberta Rosa January 2015 (has links)
Orientadora: Profa. Dra. Ahda Pionkoski Grilo Pavani / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2015. / A operação de parte da rede de distribuição de forma ilhada alimentada por geradores distribuídos aumenta os índices de confiabilidade do sistema, caso de problemas com a conexão com a rede principal reduz o tempo de indisponibilidade do fornecimento de energia elétrica para um conjunto de cargas. Os geradores síncronos distribuídos por apresentarem regulador de velocidade e controle de excitação podem mais facilmente operar no modo ilhado. Um dos grandes desafios da operação ilhada, no entanto, é a redução drástica dos níveis de curto-circuito quando a rede passa a operar de forma ilhada, comprometendo as funções de proteção dos relés de sobrecorrente. Com isso, para a operação de forma segura de uma rede ilhada é necessário alterar o ajuste da proteção dos relés de sobrecorrente. Os relés digitais apresentam a possibilidade de armazenar dois ou mais ajustes distintos de proteção, e a seleção do ajuste a ser usado pode ser realizada via um sinal externo. Neste contexto, o objetivo desta dissertação é apresentar um método capaz de identificar o estado de conexão da rede com a subestação principal e, em caso de alteração deste estado, enviar um sinal para o relé de proteção para a seleção do ajuste adequado. O método proposto não depende de comunicação e baseia-se em um dispositivo simples composto basicamente por um tiristor, que pode ser instalado próximo ao relé. O dispositivo foi modelado no MatLab e utilizado em simulações computacionais de uma rede de distribuição para validar a metodologia proposta. A rede de distribuição simulada possui capacidade de operar de forma ilhada alimentada por dois geradores síncronos distribuídos. O método proposto apresentou bom desempenho e foi capaz de identificar a condição de operação do sistema e selecionar o ajuste da proteção de forma adequada. / The capacity of part of the system to keep an autonomous operation supplied by distributed generators improves the network reliability indices, since, in case of the loss of the connection with the utility grid, it reduces the frequency and duration of interruptions for the customers. Considering that distributed synchronous generators usually have excitation system and speed regulator, they can easily control the voltage and frequency of the system and operate in the islanded mode. However, one of the challenges of islanded operation is the drastically decrease of fault current level when the system is operating in the islanded mode compared to the main system connected condition. So, to ensure a safe grid operation the overcurrent protection settings should be changed. The microprocessor-based overcurrent relay have more than one setting group and thus have the possibility to change the tripping characteristics during the operation as a function of an input signal. In this context, the objective of this thesis is to present a method capable of identifying the grid state and send a signal to the overcurrent relay in order to change the overcurrent settings. The proposed method doesn¿t depend on the communication systems for the relays, and it is based on a simple device composed by one tyristor, which can be installed next to the relay. The device was modeled in MatLab and used in computational simulations considering a typical distribution system to validate the proposed method. The distribution grid used has the capacity of operating in islanded mode or connected to the utility grid mode. The proposed method has presented a good performance and it was able to identify the operation condition in order to select the suited protection setting.
23

Avaliação do comportamento de isoladores de média tensão frente a sobretensões atmosféricas bipolares / Evaluation of the behavior of medium insulators voltage to bidirectionally atmospheric overvoltage

Silva, Alexandre Rigotti 16 August 2018 (has links)
As linhas de distribuição de energia estão frequentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2/ 50 µs). Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Este trabalho visa avaliar o comportamento de isoladores de média tensão quando sujeitos a sobretensões atmosféricas bipolares oscilatórias. Simulações realizadas usando o \"Extended Rusck Model\"(ERM) e resultados de medições demonstram que a ocorrência de sobretensões bipolares oscilatórias em linhas de distribuição não é um fato raro, pois descargas atmosféricas podem, sob certas condições, induzir tensões com tais características. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões bipolares de três períodos distintos: 2,2 µs, 4,1 µs e 6,0 µs. Este trabalho investiga o comportamento de um típico isolador de porcelana tipo pino de 15 kV sujeito a um impulso bipolar, representativo de uma tensão induzida por um raio. Mostra-se que uma modificação no método proposto por Savadamuthu et al. para estimar a suportabilidade do isolamento de pequenos (alguns milímetros) sistemas de isolamento submetidos a tensões oscilantes bipolares leva a resultados promissores em termos de previsão da ocorrência de descargas no isolador de classe 15 kV. / Power lines are often exposed to surges caused by direct and indirect lightning. The waveforms of these overvoltages may differ significantly from the standard lightning impulse used in tests to verify the adequacy of equipment insulation designs against atmospheric overvoltages (1.2/50 µs). Different models have been proposed to estimate the performance of the insulation against non-normalized impulses, with the disruptive effect model being one of the most used. This work aims at evaluating the behavior of medium voltage insulators when subjected to bidirectionally oscillating voltages. Simulations run using the Extended Rusck Model (ERM) and measurement results show that the occurrence of bipolar oscillating overvoltages are not rare on power distribution lines, as lightning strokes can induce, under certain conditions, voltages with such characteristics. Modifications performed in the circuit of a conventional high voltage pulse generator allowed the generation of bipolar voltages of three distinct periods: 2.2 µs, 4.1 µs and 6.0 µs. This work investigates the behavior of a typical 15 kV pin-type porcelain insulator subjected to bipolar impulses representative of lightning-induced voltages. It is shown that a modification on the method proposed by Savadamuthu et al. to estimate the insulation strength of small (a few mm) insulation systems subjected to bipolar oscillating voltages leads to promising results in terms of predicting the occurrence of flashovers on the 15 kV insulator.
24

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Bassi, Welson 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
25

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Bassi, Welson 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.
26

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Braz, Celso Pereira 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.
27

Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneos

Herrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.
28

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Welson Bassi 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
29

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Welson Bassi 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.
30

Localização de faltas incipientes em sistemas de distribuição de energia elétrica com cabos subterrâneos

Herrera-Orozco, Andrés Ricardo January 2017 (has links)
Nos sistemas de distribuição de alta e média tensão tem-se aumentado a utilização de linhas de distribuição de energia subterrâneas ou cabos subterrâneos. A ocorrência de faltas nas linhas afeta negativamente a qualidade da energia e o correto funcionamento da rede. O processo que leva a uma falta nos cabos é gradual e está caracterizado por uma série de subciclos de faltas incipientes associadas a uma tensão de arco. Estas, muitas vezes, passam despercebidas e, eventualmente, resultam em uma falta permanente. Os métodos clássicos de localização de faltas como as metodologias baseadas no cálculo da impedância aparente, as baseadas na inteligência artificial e as baseadas nas ondas viajantes são, habitualmente, aplicadas ao sistema depois de uma falta permanente acontecer e precisam de um ou mais ciclos do sinal para entregar uma resposta razoável. No entanto, as faltas nos cabos são um processo gradual, de curta duração (entre ¼ e ½ ciclo do sinal) e seria desejável localizar a falta incipiente antes de tornar-se permanente. Nesse contexto, esta pesquisa aborda o problema de localização de faltas incipientes. Assim, nesta tese propõe-se uma nova técnica de localização de faltas incipientes usando medições em um terminal, no domínio do tempo e que utiliza componentes de fase. Desta forma, são desenvolvidas duas novas formulações do modelo elétrico do sistema de distribuição com cabos subterrâneos durante uma falta incipiente. A abordagem proposta considera simultaneamente na sua formulação características da falta incipiente e dos sistemas de distribuição de energia, como a tensão de arco, o modelo Π nominal de parâmetros concentrados do cabo subterrâneo, o desequilíbrio do sistema e a condição da carga. A estimativa da distância da falta, junto com os parâmetros da falta incipiente, é obtida a partir da solução de um sistema sobredeterminado de equações lineares pela aplicação do método de mínimos quadrados ponderados não negativos. As formulações propostas permitem estimar a distância da falta em termos da reatância da linha até a falta. Além disso, é proposto um processo de compensação de corrente para estimar a corrente de falta; é aplicado um pré-processamento dos dados de entrada para suavizar o efeito do ruído que pode conter o sinal e, é aplicado um pós-processamento dos resultados para refinar e entregar a melhor estimativa obtida durante o processo de localização da falta. O desempenho da técnica proposta é avaliado mediante estudos de casos simulados em um circuito real de distribuição no Alternative Transients Program (ATP/EMTP) considerando análises de sensibilidade e comparativa. Também, o modelo da falta incipiente foi programado utilizando a ferramenta de MODELS do ATP/EMTP. Os resultados obtidos, considerando faltas incipientes simuladas que avaliam a influência da variação da magnitude de tensão de arco, do ruído aleatório inserido na tensão de arco, da distância da falta, da taxa de amostragem, do carregamento do sistema, do modelo de tensão de arco e de incertezas nas medições, indicam claramente que a abordagem proposta possui validade como técnica de localização de faltas incipientes, apresentando erros médios globais de 1,60% e 0,93%, respectivamente para cada formulação proposta. / The use of underground power distribution lines or underground cables in the high and medium voltage distribution systems has increased dramatically in recent years. The fault occurrence in the distribution lines negatively affects the power quality and the correct network operation. The process which leads to a fault in underground cables is gradual and is characterized by a series of sub-cycles of incipient faults associated with an arc voltage. These often are unnoticed and, eventually, results in a permanent fault. Classical fault localization methods such as the based-impedance, the based on artificial intelligent and the based on traveling waves are, usually, applied to the system after a permanent fault occurrence and need one or more signal cycles for providing a reasonable response. However, the faults in cables are a gradual process, with short duration (between ¼ to ½ of signal cycle) and would be desirable to locate the fault before this becomes a permanent fault. In this context, this research approaches the incipient faults location problem. Thus, in this thesis is proposed a new incipient fault location technique using single-end terminal measurement, in time-domain and employing phase components. In this way, two new formulations of the electrical model of the distribution system with underground cables during an incipient fault are developed. The proposed approach considers simultaneously in its formulation, incipient fault type and power distribution systems characteristics as arc voltage, unbalanced operation, load conditions and complete line model. The fault distance estimation, together with the incipient fault parameters, it is obtained from the solution of an overdetermined linear system of equations by the application of the non-negative weighted least squares estimator method. The proposed formulations allow estimating the fault distance in terms of the line reactance up to the fault. In addition, a load current compensation strategy is proposed to reduce its effect in the fault current estimation; an input data pre-processing is applied to smooth out the noise effect and a post-processing of the results is performed for estimation refinement and to provide the best estimate obtained during the fault location process. The proposed technique performance is evaluated through simulated cases studies in a real-life distribution network with underground cable data in the Alternative Transients Program (ATP/EMTP) considering sensitivity and comparative analyzes. Also, the fault model was programmed using the MODELS tool of ATP/EMTP. The obtained results, considering simulated incipient faults, which evaluate the influence of variations in the arc voltage magnitude, random noise percentage inserted in the arc voltage, fault distance, sampling rate, load dynamics, the arc voltage model and uncertainties in measurements, indicate clearly that the proposed approach is valid as incipient faults location technique, showing overall average errors of 1,60% and 0,93%, respectively for each proposed formulation.