• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 46
  • 30
  • 18
  • 15
  • 15
  • 14
  • 14
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Projeto e construcao de placas espalhadoras e degradadoras de energia para uso em radioterapia com feixe de eletrons para doencas de pele / Project and construction of energy degrading and scattering plates for electron beam radiotherapy for skin diseases

FONSECA, GABRIEL P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:32Z (GMT). No. of bitstreams: 0 / Há diversas enfermidades radiossensíveis epidermotrópicas, como a micose fungóide e a síndrome de Sézary, neoplasias cutâneas originadas de linfócitos do tipo T, que apresentam grande possibilidade de erradicação quando tratadas com feixes de elétrons com energia entre 4 e 10 MeV, conforme apontam diversos estudos. No entanto, esta técnica de tratamento apresenta inúmeras dificuldades práticas, pois a doença dissemina-se por todo o corpo do paciente tornando necessário um grande campo de radiação e deposição de energia limitada à profundidade da pele. A fim de obter uma distribuição de dose uniforme, muitas técnicas já foram desenvolvidas. Com base em estudos anteriores e guiados pelo protocolo n. 23 da American Association of Physicists in Medicine (AAPM), o presente trabalho desenvolveu placas espalhadoras e degradadoras de energia e realizou toda a dosimetria (computacional e experimental), a fim de fornecer subsídios para a implementação da técnica de tratamento Total Skin Electron Therapy (TSET) no Serviço de Radioterapia do Hospital das Clínicas de São Paulo. O programa MCNP4C baseado no método de Monte Carlo foi utilizado para reconstruir o espectro energético do acelerador Varian Clinac 2100C, por meio de medidas experimentais de percentual de dose em profundidade (PDP) e perfis radiais de dose. Com estes dados, foi possível efetuar simulações computacionais para a seleção de materiais, mediante análise da distribuição radial e axial de dose, produção de raios-X e a atenuação do feixe, além da simulação de placas espalhadoras e degradadoras de energia, a serem posicionadas na saída do acelerador. Os resultados das simulações foram validados por meio de medidas experimentais a fim de obter um grande campo de radiação com 200 cm x 80 cm que atendesse as especificações do protocolo da AAPM. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Analise dosimetrica de fontes de radiacao para uso em lesoes dermatologicas / Dosimetric analysis of radiation sources for use dermatological lesions

TADA, ARIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:14Z (GMT). No. of bitstreams: 0 / As lesões dermatológicas submetidas à terapia com fontes de radiação podem apresentar diferentes padrões de malignidade. Os tumores de pele mais comumente encontrados nos serviços de radioterapia são os carcinomas. A radioterapia de lesões dermatológicas é realizada com feixes de radiação de baixa penetração como os raios-X de ortovoltagem, feixes de elétrons e fontes radioativas (192Ir, 198Au, e 90Sr) arranjadas em moldes superficiais ou aplicadores metálicos. O presente trabalho teve como objetivo analisar o perfil de distribuição de dose terapêutica produzida por fontes de radiação utilizadas em procedimentos radioterápicos em lesões superficiais da pele. As medidas experimentais, para as análises dosimétricas das fontes de radiação, foram comparadas com cálculos obtidos no sistema computacional baseado no Método de Monte Carlo. Os resultados obtidos com os cálculos computacionais através do código MCNP-4C apresentaram uma boa concordância com as medidas experimentais. As comparações das medidas experimentais com os cálculos obtidos através do código MCNP-4C, foram utilizadas para validar os cálculos e assim possibilitar o uso de dados de simulação para aplicação em casos clínicos de rotina. A comparação entre diferentes modalidades podem fornecer um indicativo dos procedimentos mais adequados em cada caso clínico. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
23

Padronizacao do metodo de dosimetria fricke gel e avaliacao tridimensional de dose empregando a tecnica de imageamento por ressonancia magnetica / Standardization of the fricke gel dosimetry method and tridimensional dose evaluation using the magnetic resonance imaging technique

CAVINATO, CHRISTIANNE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:11Z (GMT). No. of bitstreams: 0 / Neste trabalho foi padronizado o método de obtenção da solução Fricke gel desenvolvida no IPEN. Foram comparados os resultados obtidos para diferentes qualidades do gel utilizado na preparação das soluções e a influência da concentração de gelatina na resposta das soluções dosimétricas. Testes de desempenho tais como: resposta em função da dose, limites mínimo e máximo de detecção, reprodutibilidade da resposta, entre outros, foram realizados utilizando diferentes tipos de radiação e empregando as técnicas de espectrofotometria de Absorção Óptica (AO) e Ressonância Magnética (RM). Os intervalos de dose determinados para radiação gama do Co 60 e fótons de 6 MeV estão entre 0,4 e 30,0 Gy e entre 0,5 e 100,0 Gy , empregando as técnicas de AO e RM, respectivamente. Um estudo de difusão dos íons férricos na solução foi realizado para a determinação do intervalo de tempo ótimo entre a irradiação e a avaliação das amostras; as imagens por RM podem ser obtidas com boa nitidez até 2,5 horas após a irradiação. Também foi desenvolvido um simulador esférico constituído de solução Fricke gel preparada com 5% de gelatina 270 Bloom (qualidade nacional), para a avaliação tridimensional de dose empregando a técnica de Imageamento por Ressonância Magnética (IRM). A solução Fricke gel preparada com gelatina 270 Bloom , que, além do baixo custo, pode ser adquirida facilmente no mercado nacional, apresenta resultados satisfatórios quanto à facilidade de manuseio, sensibilidade, reprodutibilidade da resposta e consistência. Os resultados obtidos confirmam sua aplicabilidade na dosimetria tridimensional pela técnica de IRM. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Implementacao e aceite de sistema de radioterapia de feixe modulado dinamico com o uso de colimador secundario de multiplas folhas / Commisioning and implantation of the dynamic intensity modulated radiation therapy using secondary multi-leaf collimator (MLC)

CECILIO, PAULO J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:01Z (GMT). No. of bitstreams: 0 / A radioterapia de feixe de intensidade modulada (IMRT) no seu modo dinâmico é uma forma de radioterapia tri-dimensional (3D), na qual modula-se um feixe de forma a obter-se a irradiação com campos que possuem perfil variável. Os campos são gerados por um sistema de otimização matemático e transformado em seqüências de movimento ou abertura de lâminas dos colimadores terciários de múltiplas folhas (MLC) ou feixe colimado helicoidal, reproduzindo a fluência de radiação adequada. No processo o operador atribui valores limitantes de dose ao alvo e aos órgãos de risco circunvizinhos para que o sistema de planejamento inverso realize a otimização possível. Após a aprovação do plano de tratamento o mesmo deve ser conferido, através de um controle de qualidade (CQ), onde são verificadas as doses que deverão ser administradas ao paciente, comprovando-se as doses obtidas e aprovadas no plano do sistema de planejamento (SPC). Para este controle os mesmos feixes e campos são medidos em termos de dose absorvida e perfis, através de dosimetria na qual comprova-se que não há erro físico ou dosimétrico no plano que irá tratar o paciente com diferença aceitável de até 5%, também utilizada como tolerância para a aprovação dos 460 casos avaliados nesta tese. Foram apresentados as metodologias para a aceitação no primeiro serviço a utilizá-la no Brasil e os testes de controle de qualidade de dois serviços de radioterapia, desde agosto de 2001 à maio de 2006 e no outro serviço de outubro de 2007 a maio de 2008, com controle de qualidade que permitiram os respectivos tratamentos clínicos com dados de 4 anos, ou seja, 460 casos com 3935 campos de tratamento verificados individualmente por dosimetria. Isto possibilitou o aperfeiçoamento da metodologia e garantia da qualidade nos tratamentos de IMRT dinâmico destes pacientes. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
25

Metodo de calculo de dose na irradiacao de todo o corpo com raios gama do cobalto-60

SCAFF, LUIZ A.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:03Z (GMT). No. of bitstreams: 1 07288.pdf: 4459666 bytes, checksum: 2665698d49d3456c8ea0e838109c5131 (MD5) / Tese (Doutaramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
26

Dosimetria aplicada na irradiacao de toda a pele utilizando feixes de eletrons com energia nominal de 4 MeV

POLI, MARIA E.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:24Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
27

Simulating Accidental Exposures to deliberate Intrusions in Pipe Networks

Nilsson, Kenneth A. 06 October 2004 (has links)
No description available.
28

Desenvolvimento e caracterização de um gel de alanina para aplicação na medida da distribuição da dose de radiação usando a técnica de espectrofotometria / Developement and characterization of an DL-Alanine gel to be applied in the measurement of the dose distribution with the spectrophotometry technique

Mizuno, Erick Yukio 24 August 2007 (has links)
Este trabalho tem por objetivo a composição e caracterização de um dosímetro à base de DL-Alanina e Ferro-ll em forma de gel para aplicações em dosimetría para campos de doses da radiação gama do Co-60 experimentadas em procedimentos de radioterapia. O aminoácido DL-Alanina é dissolvido em solução ácida contendo o Fe-ll e adicionado o gel. Procedeu-se a uma série de ensaios variando reagente a reagente e realizando procedimentos para avaliar o comportamento em função do tempo do gel dosimétrico obtido. Os espectros de absorção antes e após a irradiação apresentam máximos em 457 nm e 588 nm, respectivamente. Esses dois picos correspondem aos comprimentos de onda de absorção das espécies Fe-ll e Fe-lll, respectivamente; estando ambas as espécies em equilíbrio. Com a irradiação, ocorre a formação de radicais que oxidam o Fe-ll em Fe-lll, alterando com isso o balanço entre as duas espécies - daí o aumento da concentração de Fe-lll - fazendo com que mude a tonalidade do gel, sendo, portanto, possível de ser determinada a dose absorvida. Nas análises dos espectros e respectivas curvas dose-resposta observou-se que o gel dosimétrico apresenta linearidade no intervalo de doses entre 0,5 e 40 Gy. A partir dos resultados obtidos de linearidade, estabilidade e menor dose detectável - 0,3 Gy - conclui-se que o presente Gel Dosimétrico à base de DL-Alanina e Fe-ll apresenta excelente potencial para a finalidade que é proposto, qual seja a determinação do campo de doses em radioterapia e futura aplicação como padrão na determinação desses campos, em 3D, utilizando-se a técnica de Imagem por Ressonância Magnética - IRM. / The aim of this work is to develop a DL-Alanine, Fe-ll based gel dosimeter to be applied in the dosimetry of the Co-60 gamma-radiation fields in the dose range of radiation therapy procedures. The aminoacid DL-Alanine is dissolved in an acid solution containing the Fe-ll and added to the gel. A series of essays was performed with different chemicals and different procedures were made to evaluate the behavior of the obtained dosimetric gel as function of the time. The absorption spectra, before and after the irradiation, present maximum in 457 nm and 588 nm, respectively. These two peaks correspond to absorption wavelengths of the chemical species Fe-ll and Fe-lll, respectively, both species being in equilibrium. With the irradiation, the formation of the radicals that oxide the Fe-ll into Fe-lll occurs, altering the chemical balance of both species - hence the increase of the Fe-lll - and causing the gel to change its tonality, in such a way that it is possible to determine the absorved dose. In the analysis of the spectra and respective dose-response curves it was observed that the dosimetric gel shows linearity in dose range of 0.5 to 40 Gy. From the obtained linearity results, stability and lower detectable dose - 0,3 Gy - it is possible to conclude that the present DL-Alanine, Fe-ll based dosimetric gel presents an excellent potential to the application to which it is proposed, namely, the determination of the dose fields in radiation therapy and its future application as a standard in the determination of these fields, in 3D, using the Magnetic Resonance Imaging.
29

Desenvolvimento e caracterização de um gel de alanina para aplicação na medida da distribuição da dose de radiação usando a técnica de espectrofotometria / Developement and characterization of an DL-Alanine gel to be applied in the measurement of the dose distribution with the spectrophotometry technique

Erick Yukio Mizuno 24 August 2007 (has links)
Este trabalho tem por objetivo a composição e caracterização de um dosímetro à base de DL-Alanina e Ferro-ll em forma de gel para aplicações em dosimetría para campos de doses da radiação gama do Co-60 experimentadas em procedimentos de radioterapia. O aminoácido DL-Alanina é dissolvido em solução ácida contendo o Fe-ll e adicionado o gel. Procedeu-se a uma série de ensaios variando reagente a reagente e realizando procedimentos para avaliar o comportamento em função do tempo do gel dosimétrico obtido. Os espectros de absorção antes e após a irradiação apresentam máximos em 457 nm e 588 nm, respectivamente. Esses dois picos correspondem aos comprimentos de onda de absorção das espécies Fe-ll e Fe-lll, respectivamente; estando ambas as espécies em equilíbrio. Com a irradiação, ocorre a formação de radicais que oxidam o Fe-ll em Fe-lll, alterando com isso o balanço entre as duas espécies - daí o aumento da concentração de Fe-lll - fazendo com que mude a tonalidade do gel, sendo, portanto, possível de ser determinada a dose absorvida. Nas análises dos espectros e respectivas curvas dose-resposta observou-se que o gel dosimétrico apresenta linearidade no intervalo de doses entre 0,5 e 40 Gy. A partir dos resultados obtidos de linearidade, estabilidade e menor dose detectável - 0,3 Gy - conclui-se que o presente Gel Dosimétrico à base de DL-Alanina e Fe-ll apresenta excelente potencial para a finalidade que é proposto, qual seja a determinação do campo de doses em radioterapia e futura aplicação como padrão na determinação desses campos, em 3D, utilizando-se a técnica de Imagem por Ressonância Magnética - IRM. / The aim of this work is to develop a DL-Alanine, Fe-ll based gel dosimeter to be applied in the dosimetry of the Co-60 gamma-radiation fields in the dose range of radiation therapy procedures. The aminoacid DL-Alanine is dissolved in an acid solution containing the Fe-ll and added to the gel. A series of essays was performed with different chemicals and different procedures were made to evaluate the behavior of the obtained dosimetric gel as function of the time. The absorption spectra, before and after the irradiation, present maximum in 457 nm and 588 nm, respectively. These two peaks correspond to absorption wavelengths of the chemical species Fe-ll and Fe-lll, respectively, both species being in equilibrium. With the irradiation, the formation of the radicals that oxide the Fe-ll into Fe-lll occurs, altering the chemical balance of both species - hence the increase of the Fe-lll - and causing the gel to change its tonality, in such a way that it is possible to determine the absorved dose. In the analysis of the spectra and respective dose-response curves it was observed that the dosimetric gel shows linearity in dose range of 0.5 to 40 Gy. From the obtained linearity results, stability and lower detectable dose - 0,3 Gy - it is possible to conclude that the present DL-Alanine, Fe-ll based dosimetric gel presents an excellent potential to the application to which it is proposed, namely, the determination of the dose fields in radiation therapy and its future application as a standard in the determination of these fields, in 3D, using the Magnetic Resonance Imaging.
30

Reconstrucao de objetos simuladores segmentados aplicaveis a dosimetria de pele / Reconstruction of voxel phantoms for skin dosimetry

ANTUNES, PAULA C.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:02Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1487 seconds