• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 46
  • 30
  • 18
  • 15
  • 15
  • 14
  • 14
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinacao de fatores de conversao de dose para radiacao gama externa em residencias

MADUAR, MARCELO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:02Z (GMT). No. of bitstreams: 1 06870.pdf: 3530366 bytes, checksum: 5bddd2a5ab0508e81a57fdbb2c5f73d1 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
32

Proposição de modelos cinéticos e alométricos para a dosimetria de radiofármacos marcados com lantanídeos / Kinectic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides

LIMA, MARINA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:56Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
33

Desenvolvimento de uma metodologia computacional para calculos em dosimetria interna

YORIYAZ, HELIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:55Z (GMT). No. of bitstreams: 1 06878.pdf: 8623929 bytes, checksum: 9403b721e2a38e59f0a65c626040f7f0 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
34

Caracterização da dose em pacientes devido a produção de imagem de raios-X utilizadas em radioterapia guiada por imagem - IGRT / Characterization of dose in patients due to production ox X-ray images used in image-guired radiotherapy - IGRT

GONCALVES, VINICIUS D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:40Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
35

Determinação das curvas de isodose e confirmação do planejamento em Radioterapia de Intensidade Modulada - IMRT convencional empregando as técnicas de termoluminescência, luminescência opticamente estimulada e detectores semicondutores / Determination of isodose curves and planning confirmation in Intensity modulated radiation therapy IMRT conventional using thermoluminescent techniques, optically stimulated luminescence and semiconductor detectors

MATSUSHIMA, LUCIANA C. 20 May 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-05-20T17:36:43Z No. of bitstreams: 0 / Made available in DSpace on 2015-05-20T17:36:43Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
36

Reconstrucao de objetos simuladores segmentados aplicaveis a dosimetria de pele / Reconstruction of voxel phantoms for skin dosimetry

ANTUNES, PAULA C.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:02Z (GMT). No. of bitstreams: 0 / A radioterapia é uma modalidade terapêutica que utiliza radiações ionizantes para erradicar as células neoplásicas do organismo humano. Um dos requisitos para o sucesso desta metodologia de tratamento está na utilização adequada dos sistemas de planejamento, os quais, dentre outras informações, estimam a dose a ser administrada aos pacientes. Atualmente, códigos de transporte de radiação têm proporcionado grandes subsídios a estes sistemas de planejamento, uma vez que viabilizam avaliações dosimétricas acuradas nos órgãos e tecidos específicos de um paciente. O modelo utilizado por estes códigos para descrever a anatomia humana de forma realista é denominado Objeto Simulador Segmentado (OSS), que consiste na representação das estruturas anatômicas do corpo em discretos elementos de volume (voxels), os quais são diretamente associados aos dados tomográficos. Atualmente, os OSS possíveis de serem inseridos e processados pelo código de transporte MCNP (Monte Carlo N-Particle), apresentam voxels com resoluções da ordem de 3-4 mm. No entanto, tal resolução compromete a discriminação de algumas estruturas finas do corpo, tais como a pele. Neste contexto, o presente estudo propõe a criação de uma rotina de cálculo que discrimine a região da pele, com espessura e localização próximas do real, nos OSS e os habilite para avaliações dosimétricas acuradas. A metodologia proposta consiste na manipulação dos elementos de volume dos OSS de forma a segmentá-los e subdividi-los em diferentes espessuras de pele. A fim de validar os dados obtidos por cálculos, foram realizadas avaliações experimentais de dosimetria de pele em objetos simuladores antropomórficos com dosímetros termoluminescentes. Verificou-se, ao longo deste estudo, a importância de discriminar a região da pele com localização e espessuras próximas do real, uma vez que foram encontradas diferenças significativas entre as estimativas de dose absorvida na região pelas diferentes representações. A metodologia proposta neste estudo far-se-á útil para avaliações dosimétricas acuradas da região de pele para diversos procedimentos radioterápicos, com particular interesse na radioterapia com feixe de elétrons, na qual se destaca a terapia de irradiação de corpo inteiro (TSET Total Skin Electron Therapy), procedimento radioterápico em implementação no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP). / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
37

Determinacao de fatores de conversao de dose para radiacao gama externa em residencias

MADUAR, MARCELO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:02Z (GMT). No. of bitstreams: 1 06870.pdf: 3530366 bytes, checksum: 5bddd2a5ab0508e81a57fdbb2c5f73d1 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
38

Proposição de modelos cinéticos e alométricos para a dosimetria de radiofármacos marcados com lantanídeos / Kinectic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides

LIMA, MARINA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:56Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta dois modelos baseados em análise compartimental: modelo Animal e modelo Humano, usando imagens obtidas com mini gama câmera e dados de pacientes (obtidos da literatura) para a determinação das constantes cinéticas na biodistribuição do 177Lu-DOTATATO para três espécies animais (rato Wistar, hamster armênio e hamster sírio) e para o Humano. Os estudos de biodistribuição consideraram duas fases: a Fase 1, governada pela transferência do sangue para os órgãos e a Fase 2 governada pela excreção renal. As constantes cinéticas calculadas a partir dos dados obtidos com os animais foram usadas para a construção de escalas alométricas para prever a biodistribuição do radiofármaco 177Lu-DOTATATO empregando relações de massa, metabolismo, longevidade e parâmetros fisiológicos. Os resultados de extrapolação foram comparados com resultados calculados diretamente para os pacientes de PRRT (Peptide Receptor Radiotherapy) usando o modelo Humano. As constantes cinéticas calculadas a partir dos dados obtidos com humanos foram usadas para estimativa de dose em pacientes de PRRT considerando 26 órgãos e tecidos considerados pelo método MIRD. Os resultados de dosimetria foram concordantes com aqueles disponíveis na literatura. Para a Fase 1, as relações alométricas para as constantes cinéticas dos principais órgãos envolvidos no metabolismo e excreção do 177Lu-DOTATATO - fígado, rins e bexiga - mostraram boa correlação na projeção por massa, por metabolismo e por parâmetros fisiológicos. Para a Fase 2, apenas as constantes do sangue para os rins e do sangue para o fígado apresentaram boa correlação. Considerando o efeito de bloqueio da excreção renal pelo uso de anestésico, não se justificam tempos de medição maiores que 40 minutos para estudos in vivo, em pequenos animais. Dessa maneira, os resultados obtidos com as medições da Fase 1 da biodistribuição do 177Lu-DOTATATO em animais se apresentam como suficientes para estabelecer relações alométricas para estimativa de dose em pacientes submetidos à PRRT. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
39

Desenvolvimento de uma metodologia computacional para calculos em dosimetria interna

YORIYAZ, HELIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:55Z (GMT). No. of bitstreams: 1 06878.pdf: 8623929 bytes, checksum: 9403b721e2a38e59f0a65c626040f7f0 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
40

Caracterização da dose em pacientes devido a produção de imagem de raios-X utilizadas em radioterapia guiada por imagem - IGRT / Characterization of dose in patients due to production ox X-ray images used in image-guired radiotherapy - IGRT

GONCALVES, VINICIUS D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:40Z (GMT). No. of bitstreams: 0 / O processo de radioterapia consiste em várias etapas, iniciando na indicação pelo médico. O plano de tratamento passa então por um processo denominado simulação, onde é adquirida uma série de imagens por tomografia computadorizada que são transferidas para o sistema de planejamento, onde a delineação dos volumes alvos e tecidos normais adjacentes serão realizadas. Após a delineação desses volumes, no sistema de planejamento são colocados os campos de irradiação e a dose desejada conforme prescrição médica. O sistema de planejamento calcula então a dose que o volume alvo e os tecidos adjacentes poderão receber. Se estas doses estão dentro dos padrões aceitáveis, o planejamento então é aprovado e enviado ao acelerador linear para a execução do tratamento. Antes da execução do tratamento, é realizada uma imagem, seja através de filme radiográfico ou digitalmente, para avaliar a posição no paciente na mesa de tratamento. Se a localização do paciente está correta, a dose é então liberada. Esse protocolo de aquisição de imagem é denominado como Radioterapia Guiada por Imagem (IGRT). A quantidade de radiografias de posicionamento segue um protocolo definido conforme a região a ser irradiada. Como resultado deste procedimento, sabe-se que uma determinada dose adicional é recebida pelos pacientes, tornando-se um fator importante a ser determinado. Esta avaliação foi realizada através da simulação de Monte Carlo, utilizando o código MCNP. Para isso foi realizada primeiramente toda a caracterização da fonte de raios X com uso de câmaras de ionização e dosimetros TL juntamente com as simulações no MCNP. Após essa caracterização, as imagens e as estruturas do planejamento radioterápico foram convertidas para serem utilizadas no código MCNP. Para que as doses fossem calculadas nos principais órgãos de risco no tratamento de próstata: bexiga, reto e cabeças de fêmur direita e esquerda. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1329 seconds