Dosimétrie interne calculée sur GPU pour le traitement de tumeurs neuroendocrines à l'aide du ¹⁷⁷Lu-octréotate

Montégiani, Jean-François 20 April 2018 (has links)
Ce projet vise à élaborer un outil de calcul dosimétrique pour les traitements de thérapie radionucléique par radiopeptides (TRRP) au ¹⁷⁷Lu-octréotate. Pour ce faire, des images tomographiques par émission monophotonique et tomodensitométriques (TEM/TDM) acquises environ 4, 24 et 72 heures après l’administration du radiopharmaceutique sont recalées et quantifiées pour obtenir la biodistribution 4D du composé. Ces images permettent de calculer le taux de dose lors de la séance d’imagerie correspondante. Ces calculs sont réalisés sur processeurs graphiques afin de paralléliser le calcul de la dose. L’utilisation d’une régression biexponentielle permet d’établir les courbes de taux de dose en fonction du temps, qui sont intégrées pour obtenir la dose absorbée dans les régions étudiées. L’étude des patients ayant été traités au centre hospitalier universitaire (CHU) de Québec a permis de vérifier les résultats obtenus avec le code, en plus de s’intéresser à la prédiction de la dose rénale et la proportion de la dose absorbée due au rayonnement γ.
22

Validation d'un détecteur à fibre scintillante plastique pour la dosimétrie de photons aux énergies diagnostiques

Lessard, François 19 April 2018 (has links)
Tableau d’honneur de la Faculté des études supérieures et postdoctorales, 2012-2013. / La dosimetric dans la gamme d'énergie du kV représente l'un des défis majeurs de la radiologie diagnostique et interventionnelle ainsi qu'en radiothérapie superficielle. Les détecteurs utilisés actuellement comportent souvent des limitations quant à la justesse, du temps de réponse et de la taille. Les détecteurs à fibre scintillante plastique sont des détecteurs très prometteurs, n'offrant aucune de ces limitations. La perte de l'équivalence à l'eau causée par le gain en importance de l'effet photoélectrique avec des faisceaux entre 80 et 150 kVp est compensée par des facteurs de conversion basés sur la théorie des grandes cavités qui sont pondérés spectralement. De cette façon, la méthode est adaptable à différentes qualités de faisceau. La méthode est validée par des simulations Monte Carlo qui servent de références. La réponse du détecteur pour des faisceaux d'énergie effective variant entre 26 et 86 keV présente un coefficient de variation de 2.1% comparativement à 30% lorsqu'aucune correction est appliquée. La même méthode peut compenser le durcissement et la contribution du rayonnement diffusé lors de mesure de rendement en profondeur. Avec ce type de détecteur et la correction spectrale, il sera possible de mesurer en temps réel, avec une précision accrue, la dose reçue par le patient lors d'examens radiologiques. La petite taille du détecteur (1 mm de diamètre) ouvre la porte à des mesures in vivo afin d'obtenir des mesures expérimentales de la dose reçue non seulement à la peau mais aussi aux organes internes.
23

Étude Monte Carlo des effets de l’orientation des sources et de la présence de calcifications dans la curiethérapie de prostate à bas débit de dose

Collins Fekete, Charles-Antoine 20 April 2018 (has links)
La curiethérapie prostatique se fait en implantant des grains radioactifs dans une zone tumorale. À cause des soucis temporaux, la planification considère ces grains comme des sources ponctuelles dans un monde uniforme d’eau. Ce mémoire présente une évaluation de l’impact de deux effets perturbant la dosimétrie, avec des méthodes Monte Carlo, en curiethérapie prostatique. L’orientation des sources, négligée actuellement, risque d’altérer la dosimétrie calculée. Cet impact est évalué sur une cohorte de patients (n=287). Aucun impact n’est calculé sur la prostate et l’urètre mais un impact de -2% est calculé sur la vessie et le rectum. La présence de calcifications dans la zone tumorale est négligée par la planification actuelle. Une cohorte de patients (n=43) possédant des calcifications permet d’évaluer cet impact. Il ressort du calcul MC une différence de -13% sur le D90 du CTV et de -16% sur le D10 de l’urètre, en comparaison avec l’algorithme de planification actuel. / Prostatic brachytherapy is performed by inserting radioactive seeds in a tumoral zone. Because of time constraint, clinical planning considers those seeds as point sources in a water medium. This thesis presents the quantification of the impact of two perturbing effects on the dosimetry, evaluated through a Monte Carlo algorithm, in prostatic brachytherapy. Seeds orientation, actually neglected, may alter the clinical dosimetry. The impact of this effect is evaluated on a cohort (n=287) of patients. No effect is calculated on the prostate or the urethra but a difference of -2%, when compared to the clinical algorithm, is calculated on the OARs. Calcifications are actually neglected in the clinical planning. A cohort of patients (n=43) with visible calcifications is used to measure the effect of this approximation. MC calculations yield a difference of -13% on the CTV D90 and -16% on the urethra D10, when compared to the clinical algorithm.
24

Évaluation d'un algorithme de calcul de dose par méthode Monte Carlo pour des faisceaux d'électrons

Chamberland, Ève 16 April 2018 (has links)
Les méthodes Monte Carlo pour la planification de traitement par faisceaux d'électrons représentent une avancée significative en termes de précision de calcul de dose, comparativement aux algorithmes conventionnels de faisceaux pinceaux. Le système de planification de traitement Eclipse (Varian, Palo Alto, Ca) offre un nouvel algorithme rapide de calcul de dose par méthode Monte Carlo pour des faisceaux d'électrons de hautes énergies. Plusieurs tests ont été effectués afin d'explorer le comportement du système dans plusieurs configurations rencontrées dans les pratiques cliniques. La première série de tests a été effectuée dans un fantôme homogène d'eau. Les distributions de dose mesurées et calculées ont été comparées pour différentes combinaisons d'énergie, d'ap-plicateur et de profondeur. Ensuite, quatre différents fantômes hétérogènes simulant des matériaux de haute et basse densité furent construits afin d'explorer différentes conditions d'hétérogénéités : un petit cylindre d'air, un fantôme de poumon, un fantôme de paroi thoracique et un fantôme anthropomorphique. Enfin, l'évaluation de l'algorithme Monte Carlo s'est terminée avec l'étude rétrospective de deux cas cliniques. Comparativement à l'algorithme de faisceaux pinceaux de Pinnacle, les calculs Monte Carlo prédisent plus précisément les larges perturbations de dose dues aux hétérogénéités.
25

Modélisation d'un générateur de pénombre pour la radiothérapie externe des parois thoraciques minces après mastectomie totale

Ramanantsoa, Valérie Sandra 16 April 2018 (has links)
L'irradiation de la paroi thoracique après mastectomie permet de diminuer les risques de récidive locorégionale du cancer du sein, et d'augmenter la survie à long terme. Lors du traitement, deux faisceaux d'électrons jointifs combinés avec la technique du générateur de pénombre s'avèrent parfois utiles, lorsque la quantité de poumon irradiée en photons est trop importante. Cependant, les logiciels de planification des traitements ne sont pas prévus pour représenter cette technique. Une méthode pour implémenter la technique dans le système de planification commercial Pinnacle3 a donc été établie : le modèle est basé sur une superposition de sous-champs suivant une distribution gaussienne d'intensités. Des mesures avec une chambre à ionisation ont permis d'optimiser le choix des paramètres de superposition selon l'énergie et les caractéristiques du générateur de pénombre. Par ailleurs, un programme qui permet l'automatisation de la création des sous-champs et du calcul de leur pondération, a été développé. Ces outils permettent pour la première fois d'illustrer fidèlement les traitements des parois en électrons avec générateurs de pénombre. D'une part, les résultats du modèle sur une surface plane correspondent aux mesures et respectent les effets du générateur de pénombre. D'autre part, la planification sur un cas clinique démontre une diminution d'environ 30% du surdosage dans la région de la jonction, ce qui rend la planification plus représentative de la réalité. La pertinence des déplacements de jonctions souvent utilisés en clinique peut maintenant être évaluée objectivement.
26

Development and evaluation of low-dose rate radioactive gold nanoparticles for application in nanobrachytherapy

Laprise-Pelletier, Myriam 14 March 2024 (has links)
Depuis les dix dernières années, l’innovation des traitements d’oncologie a fait une utilisation croissante de la nanotechnologie. De nouveaux traitements à base de nanoparticules (NPs) sont notamment rendus au stade de l’essai clinique. Possédant des caractéristiques physico-chimiques particulières, les NPs peuvent être utilisées afin de bonifier l’effet thérapeutique des traitements actuels. Par exemple, l’amélioration de la curiethérapie (c.-à-d. radiothérapie interne) nécessite le développement de nouvelles procédures permettant de diminuer la taille des implants, et ce, tout en augmentant l’homogénéité de la dose déposée dans les tumeurs. Des études théoriques et expérimentales ont démontré que l’injection de NPs d’or à proximité des implants traditionnels de curiethérapie de faible débit de dose (par ex. 125I, 103Pd) permettrait d’augmenter significativement leur efficacité thérapeutique. L'interaction entre l’or et les photons émis par les implants de curiethérapie (c.-à-d. l’effet de radiosensibilisation) génère des rayonnements divers (photoélectrons, électrons Auger, rayons X caractéristiques) qui augmentent significativement la dose administrée. Dans le cadre de cette thèse, l’approche proposée était de développer des NPs d’or radioactives comme nouveau traitement de curiethérapie contre le cancer de la prostate. L’aspect novateur et unique était de synthétiser une particule coeurcoquille (Pd@Au) en utilisant l’isotope actuellement employé en curiethérapie de la prostate: le palladium-103 (103Pd, 20 keV). Dans ce cas-ci, la présence d’atomes d’or permet de produire l’effet de radiosensibilisation et d’augmenter la dose déposée. La preuve de concept a été démontrée par la synthèse et la caractérisation des NPs 103Pd@Au-PEG NPs. Ensuite, une étude longitudinale in vivo impliquant l’injection des NPs dans un modèle xénogreffe de tumeurs de la prostate chez la souris a été effectuée. L’efficacité thérapeutique induite par les NPs a été démontrée par le retard de la croissance tumorale des souris injectées par rapport aux souris non injectées (contrôles). Enfin, une étude de cartographie de la dose générée par les NPs à l’échelle cellulaire et tumorale a permis de comprendre davantage les mécanismes thérapeutiques liés aux NPs radioactives. En résumé, l’ensemble des travaux présentés dans cette thèse font office de précurseurs relativement au domaine de la nanocuriethérapie, et pourraient ouvrir la voie à une nouvelle génération de NPs pour la radiothérapie. / The last decade saw the emergence of new innovative oncology treatments based on nanotechnology. New treatments using nanoparticles (NPs) are now translated to clinical trials. NPs possess unique physical and chemical properties that can be advantageously used to improve the therapeutic effect of current treatments. For instance, therapeutic efficiency enhancement related to internal radiotherapy (i.e., brachytherapy), requires the development of new procedures leading to a decrease of the implant size, while increasing the dose homogeneity and distribution in tumors. Several theoretical and experimental studies based on low-dose brachytherapy seeds (e.g., 125I and 103Pd) combined with gold nanoparticles (Au NPs) showed very promising results in terms of dose enhancement. Gold is a radiosensitizer that enhances the efficiency of radiotherapy by increasing the energy deposition in the surrounding tissues. Dose enhancement is caused by the photoelectric products (photoelectrons, Auger electrons, characteristic X-rays) that are generated after the irradiation of Au NPs. In this thesis, the proposed approach was to develop radioactive Au NPs as a new brachytherapy treatment for prostate cancer. The unique and innovative aspect of this strategy was to synthesize core-shell NPs based on the radioisotope palladium-103 (103Pd, 20 keV), which is currently used in low-dose rate prostate cancer brachytherapy. In this concept, the administrated dose is increased via the radiosensitization effect that is generated through the interactions of low-energy photons with the gold atoms. The proof-ofconcept of this approach was first demonstrated by the synthesis and characterization of the core-shell NPs (103Pd@Au-PEG NPs). Then, a longitudinal in vivo study following the injection of NPs in a prostate cancer xenograft murine model was performed. The therapeutic efficiency was confirmed by the tumor growth delay of the treated group as compared to the control group (untreated). Finally, a mapping study of the dose distribution generated by the NPs at the cellular and tumor levels provided new insights about the therapeutic mechanisms related to radioactive NPs. In summary, the studies presented in this thesis are precursors works in the field of nanobrachytherapy, and could pave the way for a new generation of NPs for radiotherapy.
27

Amélioration du calcul de dose TG-43 en curiethérapie à bas débit par un algorithme de dose primaire et diffusée sur processeur graphique

Bourque, Alexandre 19 April 2018 (has links)
Les calculs de dose en curiethérapie à bas débit reposent depuis 1995 sur un formalisme qui considère le milieu irradié comme étant homogène et constitué d’eau afin de mieux accommoder les temps de calcul clinique. Ce travail présente une amélioration de ce formalisme dosimétrique issu du protocole TG-43 de l’AAPM (American Association of Physicists in Medicine), utilisé actuellement dans les systèmes de planification de traitement (SPT) clinique. Avec l’ajout d’un tracé radiologique pour tenir compte des hétérogénéités et en séparant la dose primaire de la dose diffusée, il est possible de raffiner les calculs dosimétriques. Or, cette modification au calcul le rendant plus complexe était coûteuse en temps d’exécution jusqu’à très récemment. Elle se voit matérialisée dans ce travail avec l’arrivée récente de la technologie GPGPU, les calculs scientifiques sur périphériques graphiques. En exploitant le parallélisme des calculs de dose en curiethérapie à bas débit pour les implants permanents, l’algorithme baptisé TG-43-RT pour TG-43 avec tracé de rayons (Ray-Tracing en anglais) permet d’obtenir des facteurs d’accélération de l’ordre de 103 par rapport au CPU. Seulement 0.5 s par source est requis dans une géométrie de 1003 voxels, et les dosimétries d’anatomies hétérogènes sont sensiblement améliorées. Le TG-43-RT corrige les dépôts de dose en aval des hétérogénéités et réduit les effets indésirables de l’atténuation inter-sources. Des écarts de dose de plus de 80% au-delà d’une calcification avaient de quoi influencer les HDV, or, le TG-43-RT ramène ces déviations en-deçà de l’incertitude de 8.7% (2σ) concédée par les SPT, tel qu’établi dans le TG-138. Les simulations Monte Carlo ont été employées pour servir de référence absolue à la méthode développée et quantifier les améliorations dosimétriques relatives à l’actuel calcul de dose. L’algorithme a été testé d’un point de vue clinique dans un fantôme de prostate avec des sources d’125I et dans un fantôme de sein avec des sources de 103Pd pour unifier les corrections apportées. / Brachytherapy dose calculations have been relying since 1995 on a formalism that considers the whole geometry as a homogeneous water tank. This gives the opportunity to compute dose distributions within a reasonable clinical timeframe, but with considerable approximations that can influence or even change the treatment. This work presents an upgraded version of this formalism derived from the TG-43 protocol (AAPM), currently used in actual treatment planning systems. The new algorithm includes a primary and scatter dose separation using ray-tracing operation to account for heterogeneities through the medium. These modifications to the dose calculation are very power consuming and too long for the clinical needs when executed on modern CPUs. With the GPGPU technology, a GPU-driven algorithm allows a complex handling of the anatomic heterogeneities in the dose calculation and keeps execution times below 0.5 s/seed. The algorithm was named TG-43-RT for TG-43 with Ray-Tracing and accelerations factors of three order of magnitude were obtained over a regular CPU implementation. The TG-43-RT algorithm adequatly corrects dose deposition along heterogeneities and it reduces interseed attenuation effects. Dose is scored in the medium instead of water, which also applies a severe correction for high heterogeneous medium like the breast. Deviations of more than 80% in dose deposition were obtained over calcification inside the prostate when compared to Monte Carlo simulations. This kind of deviation influences DVH shape. However, the TG-43-RT was keeping those deviations within the 8.7% uncertainty range (2σ) associated with a regular TG-43 evaluation as stated in the TG-138. Monte Carlo simulations were used as a gold standard to get an absolute dose calculation reference. The algorithm was also tested in a prostate phantom with 125I seeds and in a breast phantom with 103Pd seeds to mimic real anatomic geometries and unify the applied corrections.
28

Élaboration des éléments d'une simulation Monte Carlo permettant l'évaluation d'une planification de traitement en radiothérapie externe : compression d'images DICOM à l'aide d'un octree et modélisation de la tête d'un accélérateur linéaire

Hubert-Tremblay, Vincent 11 April 2018 (has links)
L'objectif de ce travail est de développer deux modules pour créer une simulation Monte Carlo ayant comme objectif futur de calculer les doses de radiation d'un traitement en radiothérapie externe. Le premier module permet de lire, modéliser et réduire le nombre de voxels présent dans une série d'images médicales de type DICOM. La réduction doit se faire tout en gardant les informations essentielles pour une simulation Monte Carlo. Un algorithme a été développé pour appliquer une compression de type octree à la distribution des densités électroniques recueillies dans les images de tomodensitométrie. L'image résultante possède ainsi une certaine anisotropie au niveau de la résolution. Des résultats obtenus, la réduction du nombre total de voxels atteinte est de l'ordre de 75% de la taille initiale. Les simulations Monte Carlo démontrent qu'aucune information dosimétrique n'est perdue après la transformation. L'efficacité de la simulation se trouve améliorée tant au niveau de sa rapidité que de son utilisation de la mémoire. Le second module développé est un modèle d'accélérateur linéaire de type Primus (Siemens). Ce modèle permet d'obtenir des distributions de doses pour deux faisceaux de photons d'énergies différentes (6 et 23 megavolts [MV]). Dans les deux cas, les distributions de doses ont été comparées à des mesures expérimentales prises avec une chambre à ionisation. Les distributions de doses dans l'axe central du faisceau ont atteint un niveau de précision de 2%. Au niveau des distributions de doses hors axe, les déviations maximales sont de l'ordre de 5% et de 2mm dans les pénombres. Pour le faisceau de 23 MV, la géométrie présente une asymétrie qui devra être corrigée en modifiant le filtre égalisateur ou en utilisant une source de radiation asymétrique. Dans tous les cas, l'ouverture des collimateurs secondaires devra être optimisée afin d'éliminer les erreurs au niveau de la pénombre. Une fois ces modifications effectuées, les images DICOM compressées avec l'octree pourront être insérées à l'intérieur du modèle de l'accélérateur. Ce faisant, il suffirait d'ajuster la configuration des faisceaux et du patient pour évaluer un traitement en radiothérapie externe.
29

Propriétés dosimétriques d'un détectecteur [sic] plat au silicium amorphe / Propriétés dosimétriques d'un détecteur plat au silicium amorphe

Cyr, Shaun 18 April 2018 (has links)
No description available.
30

Conception et validation d'une matrice 2D de détecteurs à fibres scintillantes plastiques pour la dosimétrie en radiothérapie externe

Guillot, Mathieu 19 April 2018 (has links)
Cette thèse porte sur le développement et la caractérisation d’une matrice 2D de détecteurs à fibres scintillantes plastiques pour la dosimétrie des faisceaux de photons d’énergie mégavoltage utilisés en radiothérapie. Les propriétés visées lors de la conception du détecteur matriciel furent la justesse, l’équivalence à l’eau, une bonne résolution spatiale, un nombre élevé de détecteurs, et une lecture à haute fréquence des doses déposées. La première partie de cette thèse fut consacrée à améliorer la justesse de la méthode spectrale utilisée pour corriger l’effet Cerenkov. Deux procédures aptes à extraire de façon juste les coefficients d’étalonnage ont été développées. Les résultats ont montré que cette méthode peut corriger l’effet Cerenkov avec une justesse de 1%. La seconde partie de cette thèse fut consacrée à la conception, la réalisation et la validation d’un détecteur matriciel composé de 781 dosimètres insérés dans un fantôme eau-équivalent. Un système optique a aussi été développé. Il fut déterminé qu’en moyenne, l’écart-type des mesures est inférieure à 1 % pour les doses supérieures à 6.3 cGy. Il fut aussi démontré que les distributions de dose ne sont pas perturbées (à +/- 1.1 %) par la présence des dosimètres à l’intérieur du fantôme. La caractérisation de la dépendance angulaire a révélée que les incidences des faisceaux ont peu d’impact sur la justesse des mesures. Le détecteur matriciel a aussi été validé dans le contexte de la radiothérapie à intensité modulée (IMRT). Onze plans de traitement ont été mesurés et les résultats ont montré d’excellents accords avec les doses calculées à l’aide d’algorithmes convolution-superposition ou mesurées avec des films radiochromiques. La sensibilité et la spécificité du détecteur matriciel aux erreurs de position d’une lame et d’un banc de lame d’un collimateur multi-lames (MLC) ont été déterminées en appliquant la théorie de détection du signal. Cette étude conclut que les dosimètres à fibres scintillantes plastiques pourraient permettre d’améliorer la qualité de la dosimétrie en IMRT, en raison de leurs avantages par rapport aux autres dosimètres, tels que l’équivalence à l’eau, une haute résolution spatiale, la lecture à haute fréquence, et une très faible dépendance angulaire. / This thesis deals with the development and characterization of a 2D array of plastic scintillation detectors for the dosimetry of megavoltage energy photon beams used in radiation therapy. The characteristics sought with the detector array are accuracy, water-equivalence, a good spatial resolution, a large number of detectors and a high frequency readout of the doses deposited. The first part of this thesis is devoted to the improvement of the accuracy of the spectral method used to correct the Cerenkov effect. A study has determined the optimal attenuation characteristics for the optical fibers and two procedures able to accurately extract the calibration coefficients were developed. Measurements performed in various situations showed that this method can correct the Cerenkov effect with an accuracy of 1 %. The second part of this thesis relates to the design, realization and validation of a detector array consisting of 781 plastic scintillation detectors inserted vertically into a plane of a water-equivalent phantom. An novel optical system was also designed. It was determined that, on average, the standard deviation of measurements is smaller than 1 % for doses deposited greater than 6.3 cGy. It was also demonstrated that the dose distributions are not perturbed (within +/- 1.1 %) by the presence of the detectors inside the phantom. The characterization of the angular dependence showed that the incidences of radiation beams have very little effect on the accuracy of measurements. The detector array was also validated in the context of intensity-modulated radiation therapy (IMRT). Eleven treatment plans were measured and the results showed excellent agreements with dose distributions calculated with convolution-superposition algorithms or measured with radiochromic films. The sensitivity and specificity of the detector array to position errors of one leaf and one leaf bank of a multileaf collimator (MLC) were also determined by applying the principles of signal detection theory. The study concluded that plastic scintillation detectors could allow improving the quality of dosimetry in IMRT, due to their advantages compared to other dosimeters, such as water-equivalence, high frequency readout, high spatial resolution and a very low angular dependence.