• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 5
  • 4
  • Tagged with
  • 18
  • 18
  • 11
  • 9
  • 9
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Determinação de elementos essenciais e tóxicos em sêmen bovino utilizando a espectrometria de massas com plasma acoplado (ICP-MS) com introdução direta da amostra / Determination of essential and toxicant elements in bovine semen using coupled plasma mass spectrometry (ICP-MS) with direct introduction of the sample.

Giovanna de Fatima Moreno Aguiar 03 September 2010 (has links)
Os minerais são de extrema importância no metabolismo geral e no desempenho produtivo e reprodutivo dos bovinos. Atualmente, no Brasil, existem poucos estudos sobre o diagnóstico de deficiências minerais em bovinos, através de análise de macroelementos e elementos traço em fluidos biológicos. A maior parte das informações disponíveis limitam-se ao diagnóstico clínico de deficiências isoladas e à análise de elementos nas pastagens e no solo, que podem sugerir deficiências sub clínicas de alguns minerais, mas apresentam várias limitações e interferências. O objetivo deste trabalho foi desenvolver um método de análise simples, com introdução direta da amostra, utilizando a técnica de q-ICP-MS e DRC-ICP-MS, para determinação de Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn e Pb em sêmen bovino. Para realização das análises, foi utilizada calibração em meio aquoso e as amostras foram diluídas na proporção 1:50 em solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. Também foram avaliadas a calibração por ajuste de matriz e a análise das amostras após digestão por microondas, para confirmação dos resultados obtidos por introdução direta e calibração em meio aquoso. O DRC foi essencial para determinação de níquel. O gás de reação utilizado foi H2 e os parâmetros RPq e vazão do gás foram estudados para otimização do método. Os limites de detecção para determinação de 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn e 208Pb foram: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectivamente, e para determinação de 60Ni por DRC-ICP-MS o LD foi 0,020 µgL-1. O método desenvolvido foi aplicado para determinação de 15 elementos em amostras de sêmen de bovinos de diferentes raças usadas em programas de reprodução e inseminação artificial. / The minerals are of extreme importance in the general metabolism and in the productive and reproductive performance of the bovines. Nowadays, in Brazil, few studies exist on the diagnosis of mineral deficiencies in bovine, through macroelementos analysis and trace elements in biological fluids. Most of the available information is limited to the clinical diagnosis of isolated deficiencies and the analysis of elements in the pastures and in the soil, that can suggest sub clinical deficiencies of some minerals, but present several limitations and interferences. The objective of this work was to develop a method of simple analysis, with direct introduction of the sample, using the technique of q-ICP-MS and DRC-ICP-MS, for determination of Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn and Pb in bovine semen. Aqueous medium calibration was used in the analysis and the samples were diluted in the proportion 1:50 in solution containing 0,01% v/v Triton® X-100 and 0,5% v/v of nitric acid. They were also evaluated the matrix matching and the analysis of samples after digestion for microwave, for confirmation of the results obtained by direct introduction and calibration in aqueous medium. DRC went essential for nickel determination. The reaction gas used it was H2 and the parameters RPq and gas flow rate were studied for optimization of the method. The detection limits for determination of 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn and 208Pb were: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectively, and for determination of 60Ni for DRC-ICP-MS the LOD was 0,020 µgL-1. The developed method was applied for determination of 15 elements in bovine semen samples of different breed used in reproduction programs and artificial insemination.
12

Reatividade química e fotoquímica em agregados de tensoativos em água/acetonitrila / Chemical and photochemical reactivity in aggregates of tensoactives in water/acetonitrile

Yihwa, Chang 10 September 2004 (has links)
Neste trabalho, estudou-se o efeito da adição de acetonitrila na reatividade química em soluções micelares do detergente aniônico dodecil sulfato de sódio (SDS) e do detergente catiônico brometo de hexadeciltrimetilamônio (CTAB) e em agregados supramoleculares do sal biliar, colato de sódio (NaCh). Os sistemas utilizados para estudar a reatividade química na presença de acetonitrila foram: (a) fotorreatividade do estado excitado triplete de n-butil-3-nitrofenil éter (em SDS); (b) reação de hidrólise ácida do 2-(p-octoxifenil)-1,3-dioxolano no estado fundamental (em SDS); (c) constante de incorporação do co-íon N-dodecil-4-cianopiridínio (em CTAB); (d) a protonação/desprotonação do ácido fraco 4-metil-7-hidroxiflavílio, tanto no estado excitado como no estado fundamental (em SDS); e (e) a supressão dos estados excitados de 1-etilnaftaleno e 1-(1-naftil)-etanol (em NaCh). As modificações na estruturação do agregado micelar e nas propriedades do meio aquoso, provocadas pela presença de acetonitrila, fazem com que as moléculas orgânicas e os íons saiam mais rapidamente do agregado para a fase aquosa. As mudanças que ocorrem com a micela e com a partição de solutos diminuem o efeito catalítico da micela sobre a reatividade química. Os agregados de sal biliar possuem dois sítios distintos de ligação de solutos e a concentração mínima de sal biliar necessária para formar esses dois sítios depende da concentração de acetonitrila. Em concentrações de acetonitrila acima de 10 %, ocorre somente a formação de agregados com sítio primário, enquanto que acima de 30 % os agregados se desfazem por completo. Em baixas concentrações de acetonitrila (até aproximadamente 10 %), a dinâmica de dissociação de solutos do sítio secundário do agregado de sal biliar não modifica muito, enquanto que a velocidade de saída de solutos do sítio primário aumenta com a presença da acetonitrila. Desse modo, a acetonitrila pode ser empregada para acelerar a saída de uma espécie, tal como um intermediário reativo, do agregado primário, facilitando a aplicação de agregados de sal biliar como micro-reatores com dois sítios distintos de reação. / This work reports a study of the effect of the addition of acetonitrile on chemical reactivity in micellar solutions of the anionic detergent sodium dodecyl sulfate (SDS) and the cationic detergent hexadecyltrimethylammonium bromide (CTAB) and in supramolecular aggregates of the bile salt sodium cholate (NaCh). The systems employed in the study of chemical reactivity in the presence of acetonitrile were: (a) photoreactivity of the excited triplet state of N-butyl-3-nitrophenyl ether in SDS; (b) the acid catalyzed of 2-(p-octoxy-nitrophenyl)-1,3-dioxolane in the ground state in SDS; (c) incorporation of the coion N-dodecyl-4-cyanopyridine in CTAB; (d) protonation/deprotonation of the weak acid of the 4-methyl-7-hydroxyflavilium ion in the ground and excited state in SDS; and (e) quenching of the excited state of 1-ethylnaphthalene and 1-(1-naphthyl)-ethanol in NaCh. The modifications of the structure of the micellar aggregate and of the properties of the bulk aqueous phase induced by acetonitrile result in a faster rate of exit of organic molecules and ions from the aggregate into the aqueous phase. The changes that occur in the micelle and in the partitioning of solutes tend to diminish the catalytic effect of micelles on chemical reactivity. Bile salt aggregates possess two distinct sites for solubilization of solutes and the minimum concentration of bile salt necessary for the formation of these two sites depends on the concentration of acetonitrile. At acetonitrile concentrations above 10 %, only aggregates with the primary solubilization site are formed and, above 30 %, the aggregates are completely disrupted. At low acetonitrile concentrations (below 10 %), the dynamics of dissociation of solutes from the secondary site of bile salt aggregates changes very little, while the rate of exit of solutes from the primary site increases in the presence of acetonitrile. Thus, acetonitrile can be employed to accelerate the rate of exit of species such as reactive intermediates, facilitating the application of bile salt aggregates as two-reaction-site microreactors.
13

Avaliação do uso da cela de reação dinâmica em espectrometria de massas com plasma acoplado indutivamente (DRC-ICP-MS) para determinação de elementos químicos em sangue / Evaluation of the use of dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for determination of elements in whole blood

Batista, Bruno Lemos 30 April 2009 (has links)
A espectrometria de massas com plasma acoplado indutivamente com simples quadrupolo (q-ICP-MS) e cela de reação dinâmica (DRC-ICP-MS) foi avaliada para determinação seqüencial de Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V e Zn em sangue. Para as análises, amostras de sangue (200 µL) foram diluídas 1:50 em uma solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. As calibrações foram realizadas com ajuste de matriz, utilizando sangue ovino. Como gás de reação utilizou-se a NH3. O uso do DRC foi fundamental para a determinação de Cr e V. A escolha da melhor vazão do gás e a otimização do parâmetro de rejeição (RPq) foram estudadas utilizando sangue base ovino ou uma solução de matriz sintética (SMS), de acordo com a concentração do analito no sangue base. Os limites de detecção (3s/coeficiente angular) para determinação de 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl e 66Zn em sangue por q-ICP-MS foram 0,223; 0,014; 0,003; 0,011; 0,304; 0,009; 0,009; 0,003; 0,001; 0,005; 0,264; 0,006; 0,010; 0,001; 0,834 µg L-1, respectivamente, e para determinação de 52Cr e 51V em sangue por DRC-ICP-MS utilizando o gás de reação amônia os limites de detecção foram de 0,007 e 0,006 µg L-1. Para a determinação de 27Al, 63Cu, 65Cu, 64Zn e 66Zn em sangue por q-ICP-MS através da calibração com ajuste de matriz com SMS os limites de detecção foram 0,083; 0,090; 0,055; 0,281; 0,306 µg L-1, respectivamente. A validação do método foi realizada por meio da análise de materiais de referência do INSP-Canadá, NYSDOH-EUA e Seronorm-Noruega. / The use of inductively coupled plasma mass spectrometry with quadrupole (q-ICP-MS) and dynamic reaction cell (DRC-ICP-MS) was evaluated for sequential determination of Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V and Zn in whole blood by q-ICP-MS or DRC-ICP-MS methods. Prior to analysis, sample (200 µL) were diluted 1:50 v/v in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid. For all elements, except Cr and V, the instrument was operated in q-ICP-MS mode. The use of DRC was only mandatory for Cr and V. NH3 was evaluated as the reaction gas. Selection of best flow rate of reaction gas and optimization of the quadrupole dynamic bandpass rejection parameter (RPq) were carried out, using base whole blood or synthetic matrix solution (SMS), in according with element base blood concentration. Method detection limits (3s/slope) for 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl and 66Zn determination in whole blood by q-ICP-MS against matrix matching calibration (base blood) were 0.223; 0.014; 0.003; 0.011; 0.304; 0.009; 0.009; 0.003; 0.001; 0.005; 0.264; 0.006; 0.010; 0.001; 0.834 µg L-1, respectively, and for 52Cr and 51V determination in whole blood by DRC-ICP-MS the detection limits were 0.007 e 0.006 µg L-1. For 27Al, 63Cu, 65Cu, 64Zn and 66Zn determination by q-ICP-MS through matrix matching calibration with SMS the detection limits were 0.083; 0.090; 0.055; 0.281; 0.306 µg L-1, respectively. Method validation was accomplished by the analysis of reference materials from INSP-Canada, NYSDOH-USA, Seronorm-Norway.
14

EXPERIMENTAL STUDY OF BLAST RESISTANT GLAZING SYSTEM RESPONSE TO EXPLOSIVE LOADING

Wedding, William Chad 01 January 2010 (has links)
This thesis recounts the experimental study of the dynamic response of a blast resistant glazing system to explosive loading. A combination of triaxial force sensors, pressure gauges, and laser displacement gauges capture the response in detail over a wide range of scenarios. The scenarios include low level blast loading to characterize the reaction at points around the perimeter of the window, moderate level blast loading to examine the repeatability of the blast scenario, and high level blast loading to capture the response during failure as the tensile membrane forms. The scenarios are modeled via an analytical Single-Degree-of-Freedom model as well as finite element modeling in ANSYS Explicit Dynamics. In addition, this study investigates some of the differences between experimental data and the predictions made by modeling.
15

Avaliação do uso da cela de reação dinâmica em espectrometria de massas com plasma acoplado indutivamente (DRC-ICP-MS) para determinação de elementos químicos em sangue / Evaluation of the use of dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for determination of elements in whole blood

Bruno Lemos Batista 30 April 2009 (has links)
A espectrometria de massas com plasma acoplado indutivamente com simples quadrupolo (q-ICP-MS) e cela de reação dinâmica (DRC-ICP-MS) foi avaliada para determinação seqüencial de Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V e Zn em sangue. Para as análises, amostras de sangue (200 µL) foram diluídas 1:50 em uma solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. As calibrações foram realizadas com ajuste de matriz, utilizando sangue ovino. Como gás de reação utilizou-se a NH3. O uso do DRC foi fundamental para a determinação de Cr e V. A escolha da melhor vazão do gás e a otimização do parâmetro de rejeição (RPq) foram estudadas utilizando sangue base ovino ou uma solução de matriz sintética (SMS), de acordo com a concentração do analito no sangue base. Os limites de detecção (3s/coeficiente angular) para determinação de 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl e 66Zn em sangue por q-ICP-MS foram 0,223; 0,014; 0,003; 0,011; 0,304; 0,009; 0,009; 0,003; 0,001; 0,005; 0,264; 0,006; 0,010; 0,001; 0,834 µg L-1, respectivamente, e para determinação de 52Cr e 51V em sangue por DRC-ICP-MS utilizando o gás de reação amônia os limites de detecção foram de 0,007 e 0,006 µg L-1. Para a determinação de 27Al, 63Cu, 65Cu, 64Zn e 66Zn em sangue por q-ICP-MS através da calibração com ajuste de matriz com SMS os limites de detecção foram 0,083; 0,090; 0,055; 0,281; 0,306 µg L-1, respectivamente. A validação do método foi realizada por meio da análise de materiais de referência do INSP-Canadá, NYSDOH-EUA e Seronorm-Noruega. / The use of inductively coupled plasma mass spectrometry with quadrupole (q-ICP-MS) and dynamic reaction cell (DRC-ICP-MS) was evaluated for sequential determination of Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V and Zn in whole blood by q-ICP-MS or DRC-ICP-MS methods. Prior to analysis, sample (200 µL) were diluted 1:50 v/v in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid. For all elements, except Cr and V, the instrument was operated in q-ICP-MS mode. The use of DRC was only mandatory for Cr and V. NH3 was evaluated as the reaction gas. Selection of best flow rate of reaction gas and optimization of the quadrupole dynamic bandpass rejection parameter (RPq) were carried out, using base whole blood or synthetic matrix solution (SMS), in according with element base blood concentration. Method detection limits (3s/slope) for 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl and 66Zn determination in whole blood by q-ICP-MS against matrix matching calibration (base blood) were 0.223; 0.014; 0.003; 0.011; 0.304; 0.009; 0.009; 0.003; 0.001; 0.005; 0.264; 0.006; 0.010; 0.001; 0.834 µg L-1, respectively, and for 52Cr and 51V determination in whole blood by DRC-ICP-MS the detection limits were 0.007 e 0.006 µg L-1. For 27Al, 63Cu, 65Cu, 64Zn and 66Zn determination by q-ICP-MS through matrix matching calibration with SMS the detection limits were 0.083; 0.090; 0.055; 0.281; 0.306 µg L-1, respectively. Method validation was accomplished by the analysis of reference materials from INSP-Canada, NYSDOH-USA, Seronorm-Norway.
16

Reatividade química e fotoquímica em agregados de tensoativos em água/acetonitrila / Chemical and photochemical reactivity in aggregates of tensoactives in water/acetonitrile

Chang Yihwa 10 September 2004 (has links)
Neste trabalho, estudou-se o efeito da adição de acetonitrila na reatividade química em soluções micelares do detergente aniônico dodecil sulfato de sódio (SDS) e do detergente catiônico brometo de hexadeciltrimetilamônio (CTAB) e em agregados supramoleculares do sal biliar, colato de sódio (NaCh). Os sistemas utilizados para estudar a reatividade química na presença de acetonitrila foram: (a) fotorreatividade do estado excitado triplete de n-butil-3-nitrofenil éter (em SDS); (b) reação de hidrólise ácida do 2-(p-octoxifenil)-1,3-dioxolano no estado fundamental (em SDS); (c) constante de incorporação do co-íon N-dodecil-4-cianopiridínio (em CTAB); (d) a protonação/desprotonação do ácido fraco 4-metil-7-hidroxiflavílio, tanto no estado excitado como no estado fundamental (em SDS); e (e) a supressão dos estados excitados de 1-etilnaftaleno e 1-(1-naftil)-etanol (em NaCh). As modificações na estruturação do agregado micelar e nas propriedades do meio aquoso, provocadas pela presença de acetonitrila, fazem com que as moléculas orgânicas e os íons saiam mais rapidamente do agregado para a fase aquosa. As mudanças que ocorrem com a micela e com a partição de solutos diminuem o efeito catalítico da micela sobre a reatividade química. Os agregados de sal biliar possuem dois sítios distintos de ligação de solutos e a concentração mínima de sal biliar necessária para formar esses dois sítios depende da concentração de acetonitrila. Em concentrações de acetonitrila acima de 10 %, ocorre somente a formação de agregados com sítio primário, enquanto que acima de 30 % os agregados se desfazem por completo. Em baixas concentrações de acetonitrila (até aproximadamente 10 %), a dinâmica de dissociação de solutos do sítio secundário do agregado de sal biliar não modifica muito, enquanto que a velocidade de saída de solutos do sítio primário aumenta com a presença da acetonitrila. Desse modo, a acetonitrila pode ser empregada para acelerar a saída de uma espécie, tal como um intermediário reativo, do agregado primário, facilitando a aplicação de agregados de sal biliar como micro-reatores com dois sítios distintos de reação. / This work reports a study of the effect of the addition of acetonitrile on chemical reactivity in micellar solutions of the anionic detergent sodium dodecyl sulfate (SDS) and the cationic detergent hexadecyltrimethylammonium bromide (CTAB) and in supramolecular aggregates of the bile salt sodium cholate (NaCh). The systems employed in the study of chemical reactivity in the presence of acetonitrile were: (a) photoreactivity of the excited triplet state of N-butyl-3-nitrophenyl ether in SDS; (b) the acid catalyzed of 2-(p-octoxy-nitrophenyl)-1,3-dioxolane in the ground state in SDS; (c) incorporation of the coion N-dodecyl-4-cyanopyridine in CTAB; (d) protonation/deprotonation of the weak acid of the 4-methyl-7-hydroxyflavilium ion in the ground and excited state in SDS; and (e) quenching of the excited state of 1-ethylnaphthalene and 1-(1-naphthyl)-ethanol in NaCh. The modifications of the structure of the micellar aggregate and of the properties of the bulk aqueous phase induced by acetonitrile result in a faster rate of exit of organic molecules and ions from the aggregate into the aqueous phase. The changes that occur in the micelle and in the partitioning of solutes tend to diminish the catalytic effect of micelles on chemical reactivity. Bile salt aggregates possess two distinct sites for solubilization of solutes and the minimum concentration of bile salt necessary for the formation of these two sites depends on the concentration of acetonitrile. At acetonitrile concentrations above 10 %, only aggregates with the primary solubilization site are formed and, above 30 %, the aggregates are completely disrupted. At low acetonitrile concentrations (below 10 %), the dynamics of dissociation of solutes from the secondary site of bile salt aggregates changes very little, while the rate of exit of solutes from the primary site increases in the presence of acetonitrile. Thus, acetonitrile can be employed to accelerate the rate of exit of species such as reactive intermediates, facilitating the application of bile salt aggregates as two-reaction-site microreactors.
17

Interpretação de resultados do ensaio SPT com base em instrumentação dinâmica / Interpretation of SPT test results based on dynamic instrumentation

Lukiantchuki, Juliana Azoia 27 July 2012 (has links)
O ensaio de simples reconhecimento do solo (SPT) e usualmente utilizado para estimar a resistência do solo, atraves do índice NSPT, que representa a resistencia a penetração dinâmica do amostrador no solo. Esse índice é usado diretamente em correlações empíricas ou semi-empíricas na determinação da capacidade de suporte e recalque das fundações. Entretanto, esse ensaio tem sido alvo de críticas devido a utilização dessas correlações empíricas, geralmente baseadas em observações práticas e sem nenhum fundamento científico. Críticas também estão relacionadas com a dispersão dos resultados, devido a utilização de diferentes tipos de equipamentos e procedimentos executivos. O índice NSPT depende da parcela de energia que e efetivamente transmitida ao amostrador durante a queda do martelo. Assim, análises racionais dos resultados de ensaios SPT dependem essencialmente da estimativa da quantidade dessa energia. Por esse motivo, tem sido desenvolvidas diversas pesquisas relacionados com a energia envolvida no ensaio SPT. Este trabalho apresenta interpretações dos resultados do ensaio SPT a partir das quantidades de energia envolvidas durante a queda do martelo. Essas quantidades de energia são determinadas indiretamente, através dos sinais de força normal e aceleração durante a propagação da onda de tensão ao longo da composição de hastes. Para isso, foi desenvolvido um equipamento que inclui uma instrumentação capaz de registrar esses sinais de força normal e aceleração. Uma série de ensaios SPT foi realizada com instrumentação instalada tanto no topo como na base da composição de hastes. Esse arranjo permitiu estimar as quantidades de energia disponíveis no topo e na base da composição de hastes. Assim, foi possível determinar a eficiência dos equipamentos SPT com base na quantidade de energia que efetivamente atinge o amostrador. A partir dos sinais registrados, também foi possível determinar a resistência dinâmica mobilizada no sistema solo-amostrador. Os resultados experimentais foram comparados com resultados obtidos através de métodos teóricos, baseados no Princípio de Hamilton, para a determinação da resistência estática e dinâmica do solo. Essas análises mostraram que equações teóricas podem ser adequadas para a determinação da resistência do solo, desde que seja considerada a quantidade de energia que efetivamente atinge o amostrador. Desta forma, essas equações teóricas podem ser facilmente incorporadas na prática de projeto de fundações, contribuindo para o desenvolvimento de métodos baseados na quantidade de energia necessária para a penetração do amostrador no solo. / The standard penetration test (SPT) is usually used to estimate the soil strength through the NSPT index which represents the dynamic reaction force of the sampler penetration into the soil. This index is directly used in empirical or semi-empirical correlations for the determination of the bearing capacity and foundation settlements. However, this test has been criticized due to the use of these empirical correlations, often based on practical observation without any scientific basis. Criticism is also related to result dispersion due to the use of different types of equipment and execution procedures. The NSPT index depends on the amount of energy that is effectively transmitted to the sampler during the hammer fall. Thus, rational analyses of the SPT test results essentially depend on the estimation of this amount of energy. For this reason, several studies related to the energy involved in SPT test have been developed. This research presents interpretations of the SPT test results from the amounts of energy involved during the hammer fall. These amounts of energy are indirectly assessed by means of normal force and acceleration signals during the stress wave propagation along the string of rods. For this reason, a device that includes instrumentation capable of registering these signals of normal force and acceleration was developed. A series of tests was performed with the instrumentation installed at the top and the bottom of the string of rods. This arrangement allowed estimating the amount of energy available at the top and bottom of the string of rods. Thus, it was possible to estimate the efficiency of the SPT equipment basing on the amount of energy that actually reaches the sampler. From the recorded signals, it was also possible to assess the dynamic reaction force mobilized in the soil-sample system. The results were compared with other results obtained by theoretical methods, based on the Hamilton´s Principle, for evaluating the static and dynamic reaction force of the soil. These analyzes have shown that theoretical equations may be suitable for the determination of the soil strength, provided that the amount of energy that actually reaches the sampler be considered. Thus, these theoretical equations can be easily incorporated into the practice of foundation designs contributing to the development of methods based on the amount of energy required for the penetration of the sampler into the soil.
18

Interpretação de resultados do ensaio SPT com base em instrumentação dinâmica / Interpretation of SPT test results based on dynamic instrumentation

Juliana Azoia Lukiantchuki 27 July 2012 (has links)
O ensaio de simples reconhecimento do solo (SPT) e usualmente utilizado para estimar a resistência do solo, atraves do índice NSPT, que representa a resistencia a penetração dinâmica do amostrador no solo. Esse índice é usado diretamente em correlações empíricas ou semi-empíricas na determinação da capacidade de suporte e recalque das fundações. Entretanto, esse ensaio tem sido alvo de críticas devido a utilização dessas correlações empíricas, geralmente baseadas em observações práticas e sem nenhum fundamento científico. Críticas também estão relacionadas com a dispersão dos resultados, devido a utilização de diferentes tipos de equipamentos e procedimentos executivos. O índice NSPT depende da parcela de energia que e efetivamente transmitida ao amostrador durante a queda do martelo. Assim, análises racionais dos resultados de ensaios SPT dependem essencialmente da estimativa da quantidade dessa energia. Por esse motivo, tem sido desenvolvidas diversas pesquisas relacionados com a energia envolvida no ensaio SPT. Este trabalho apresenta interpretações dos resultados do ensaio SPT a partir das quantidades de energia envolvidas durante a queda do martelo. Essas quantidades de energia são determinadas indiretamente, através dos sinais de força normal e aceleração durante a propagação da onda de tensão ao longo da composição de hastes. Para isso, foi desenvolvido um equipamento que inclui uma instrumentação capaz de registrar esses sinais de força normal e aceleração. Uma série de ensaios SPT foi realizada com instrumentação instalada tanto no topo como na base da composição de hastes. Esse arranjo permitiu estimar as quantidades de energia disponíveis no topo e na base da composição de hastes. Assim, foi possível determinar a eficiência dos equipamentos SPT com base na quantidade de energia que efetivamente atinge o amostrador. A partir dos sinais registrados, também foi possível determinar a resistência dinâmica mobilizada no sistema solo-amostrador. Os resultados experimentais foram comparados com resultados obtidos através de métodos teóricos, baseados no Princípio de Hamilton, para a determinação da resistência estática e dinâmica do solo. Essas análises mostraram que equações teóricas podem ser adequadas para a determinação da resistência do solo, desde que seja considerada a quantidade de energia que efetivamente atinge o amostrador. Desta forma, essas equações teóricas podem ser facilmente incorporadas na prática de projeto de fundações, contribuindo para o desenvolvimento de métodos baseados na quantidade de energia necessária para a penetração do amostrador no solo. / The standard penetration test (SPT) is usually used to estimate the soil strength through the NSPT index which represents the dynamic reaction force of the sampler penetration into the soil. This index is directly used in empirical or semi-empirical correlations for the determination of the bearing capacity and foundation settlements. However, this test has been criticized due to the use of these empirical correlations, often based on practical observation without any scientific basis. Criticism is also related to result dispersion due to the use of different types of equipment and execution procedures. The NSPT index depends on the amount of energy that is effectively transmitted to the sampler during the hammer fall. Thus, rational analyses of the SPT test results essentially depend on the estimation of this amount of energy. For this reason, several studies related to the energy involved in SPT test have been developed. This research presents interpretations of the SPT test results from the amounts of energy involved during the hammer fall. These amounts of energy are indirectly assessed by means of normal force and acceleration signals during the stress wave propagation along the string of rods. For this reason, a device that includes instrumentation capable of registering these signals of normal force and acceleration was developed. A series of tests was performed with the instrumentation installed at the top and the bottom of the string of rods. This arrangement allowed estimating the amount of energy available at the top and bottom of the string of rods. Thus, it was possible to estimate the efficiency of the SPT equipment basing on the amount of energy that actually reaches the sampler. From the recorded signals, it was also possible to assess the dynamic reaction force mobilized in the soil-sample system. The results were compared with other results obtained by theoretical methods, based on the Hamilton´s Principle, for evaluating the static and dynamic reaction force of the soil. These analyzes have shown that theoretical equations may be suitable for the determination of the soil strength, provided that the amount of energy that actually reaches the sampler be considered. Thus, these theoretical equations can be easily incorporated into the practice of foundation designs contributing to the development of methods based on the amount of energy required for the penetration of the sampler into the soil.

Page generated in 0.3416 seconds