• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1941
  • 582
  • 218
  • 207
  • 182
  • 164
  • 70
  • 55
  • 49
  • 39
  • 38
  • 31
  • 19
  • 15
  • 12
  • Tagged with
  • 4431
  • 561
  • 459
  • 319
  • 315
  • 294
  • 286
  • 265
  • 204
  • 198
  • 198
  • 187
  • 179
  • 169
  • 167
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
631

Cylindrical Detector and Preamplifier Design for Detecting Neutrons

Xia, Zhenghua 14 January 2010 (has links)
Tissue equivalent proportional counters are frequently used to measure dose and dose equivalent in mixed radiation fields that include neutrons; however, detectors simulating sites 1?m in diameter underestimate the quality factor, Q, for low energy neutrons because the recoil protons do not cross the detectors. Proportional counters simulating different site-sizes can be used to get a better neutron dose equivalent measurement since the range and stopping power of protons generated by neutrons in the tissue-equivalent walls depend on the energy of the primary neutrons. The differences in the spectra measured by different size detectors will provide additional information on the incident neutron energy. Monte Carlo N-particle extended (MCNPX) code was used to simulate neutron transportation in proportional counters of different simulated tissue diameter. These Monte Carlo results were tested using two solid walled tissue equivalent proportional counters, 2mm and 10mm in diameter, simulating tissue volumes 0.1?m and 0.5?m in diameter, housed in a single vacuum chamber. Both detectors are built with 3mm thick tissue equivalent plastic (A-150) walls and propane gas inside for dose measurement. Using these two detectors, the spectra were compared to determine the underestimation of y for large detector, and thereby obtain more information of the incident neutron particles. Based on the MCNPX simulation and experimental results, we can see that the smaller detector produces a larger average lineal energy than the larger detector, which means the larger detector (0.5?m diameter tissue equivalent size) underestimates the Q value for the low energy neutron, therefore underestimates the effective dose. These results confirm the results of the typical analysis of lineal energy as a function of site size.
632

Mesh regulations of bottom trawl for the protection of economic immature fishes off southwestern Taiwan

Huang, Meng-Hsun 09 September 2008 (has links)
The present research adopts with the application of the sequential mesh regulations on bottom trawl to study how to protect economic immature fishes. The experimental design includes first the determination of the relationships of fish size and the price per weight (PPW) of the economic demersal fishes sold as the one-hundred Dollars-a-plate manner in Tunkang and Zihguan fish markets in the southwestern coast of Taiwan. The obtained results were used to yield the catch of smaller size fishes and the lower PPW for regulating the economic immature fishes. The three kinds of regulated fish size were defined as the smallest surveyed size, smallest economic size, and smallest matured size. These regulated fish size were used as the body lengths of 50% selection (L50) to calculate the regulating mesh size. This study presents that four steps are needed for the sequential mesh regulations of bottom trawl in the southwestern Taiwan. The first step is to regulate the mesh size between 35 and 45 mm for banning bottom trawler to catch fishes smaller than the smallest surveyed fish size. The objective of first step is to reduce the bycatch without affecting the landings of economic immature fishes sold in the fish market. The second step is to regulate the mesh size between 50 and 60 mm for banning bottom trawler catch fishes smaller than the smallest economic fish size, and to reduce the catch of smaller size fishes and the lower PPW of economic immature fishes. The third step is to regulate the mesh size between 65 and 70 mm for banning bottom trawler to catch fishes smaller than the smallest matured fish size. This is also to reduce the catch of economic immature fishes, and to increase the recruitment. The fourth step is to regulate the mesh size between 70 and 82 mm for banning bottom trawler catching the lower PPW of economic fishes that is not large enough to reach their optimal PPW. The present research provides important data results for regulating the mesh size of bottom trawler operation for the achievement of sustainable coastal fishery in Taiwan.
633

Investigation of Soldier Crabs, Mictyris brevidactylus, as a Biomonitor for Heavy Metal Contamination

Yeh, Hiao-Chien 12 February 2009 (has links)
This study is the first attempt to investigate heavy metal concentrations in the soldier crab with a view to it being a potential candidate for the monitoring of copper(Cu), zinc(Zn), nickel(Ni), lead(Pb) and cadmium(Cd) levels on the western coast of Taiwan. The objectives of this investigation included the following: (1) to assess the pollution status at different sites by determining the metal concentrations of ambient water and Pacific oysters; (2) to monitor the concentrations of heavy metals, including Cu, Zn, Ni, Pb and Cd, in the soldier crab; (3) to assess the effect of sex, wet weight and reproductive season at different sites¡F(4) to investigate the distribution of metal concentration among carapace, gonads, midgut gland, muscle; and (5). to assess the pollution status at different sites and years by monitoring the concentration of heavy metals, including Cu, Zn, Pb and Cd in male soldier crabs The Pacific oyster and stream results proved that site B is contaminated by Cu, Zn and Pb from streams B-1 and B-2. The highest Cu, Zn, Ni and Pb concentrations in soldier crabs appeared at site B, and significant differences in the accumulated concentrations of Cu, Pb, Zn and Ni in soldier crabs were found between the sites tested. The highest bioconcentration factors of Cu, Zn, Ni and Pb in soldier crabs appeared at site B, indicating that the soldier crab can accumulate Cu, Zn and Pb to the same degree as the Pacific oyster. In fact, soldier crabs can accumulate more Ni than Pacific oysters, better reflecting the conditions of the ambient environment. These phenomena, as well as the fact that the soldier crab is able to accumulate relatively high levels of Cu, Zn, Pb and Ni, suggest that this crab is a potential biomonitor of Pb and Ni pollution in aquatic ecosystems. Only in the case at site A of Pb sex related difference could be detected. In general mean Pb level in male soldier crabs were higher than in female. There are no significant sex related differences of Cu, Zn, Cd and Ni in soldier crab among three sites. The lead mean concentration in reproduction season and pre- reproduction season were higher than non-reproduction seasons. The highest concentrations of lead were found in carapace and the gonad in reproduction season. The results presented that the metal concentration in soldier crabs vary significantly not only because of season change in polluted sites, but also it may be influenced by the sex-related and size-related difference of organisms. After eliminating size effect, sex effect by analyzing 0.7 g~ 1.0 g and male soldier crabs to monitor the pollution status, the Cu and Zn concentrations in soldier crabs along the Changhua coastline(site A and site B) is stable¡F The higher concentrations of Pb and Cd in soldier crabs existed in 2002 and 2003. We suggested that the polluted sources of Pb and Cd along the Changhua coastline in 2002 is abundant, and of Pb contents from 2003 to 2006 and Cd content from 2003 to 2007 are decreasing. Therefore, it is essential to take size effect, sex, season, and polluted status into account in comparative biomonitoring studies using soldier crabs as metals biomonitor. The baseline concentration of soldier crabs were 21.4 £gg g-1 wet wt. Cu, 20.1 £gg g-1 wet wt. Zn, 0.13 £gg g-1 wet wt. Pb, 0.12 £gg g-1 wet wt. and 0.91 £gg g-1 wet wt..
634

Manufacturihng of heavy rings and large copper canisters by plastic deformation

Ssemakula, Hamzah January 2003 (has links)
<p>Plastic deformation processes transform material fromas-received state to products meeting certain requirements inproperties, microstructure and shape. To achieve thistransformation, the relationship between material response andprocess conditions should be understood. This is usuallycomplicated by the complex conditions describing the actualprocess. Numerous techniques including empirical, physical,analytical and numerical can be employed.</p><p>In this thesis, numerical technique supported by lab- andfull-scale experiments has been employed to analyse the formingparameters. The first part of the thesis is focused on the useof such parameters to predict occurrence of material poresduring manufacturing of bearing rings. The second part dealswith the influence of forming parameters on the grain sizeduring fabrication of large copper canisters for encapsulationof nuclear waste. The primary task has been to study with thehelp of commercial FE-codes the magnitude and distribution offorming parameters such as accumulated effective strain,temperature, instantaneous hydrostatic pressure and materialflow at different stages of the forming process. In the firstpart, two types of ring manufacturing routes, which result inpore free and pore loaded rings are studied and compared.Material elements located in different areas of the workpiecehave been traced throughout the process. Results of theaccumulated strain and instant hydrostatic pressure have beenanalysed and presented in pressure-strain space. It’sassumed that high hydrostatic pressures together with higheffective strains are favourable for pore closure. Area of theworkpiece with unfavourable parameters have been identified andcompared with ultrasonic test results. Good agreement has beenobtained. Based on the results of this analysis, a new conceptfor avoiding pores in manufacturing of yet heavier rings hasbeen presented. The concept proposes a lighter upsetting in theinitial stage of the process and a more efficient piercingwhich results in higher hydrostatic pressure and bigger andbetter distributed effective strain.</p><p>In the second part of the thesis, the influence of formingparameters such as effective strain and temperature on thefinal grain size of the product has been studied in laboratoryscale. As-cast billets of cylindrical shape were extruded atdifferent temperatures and reductions. It has been shown thatthe grain size in the final product should be small in order toenable ultrasonic tests and to guarantee resistance towardscreep and corrosion. Simulations for different materialelements located at different distances from the axis ofsymmetry of the initial cylindrical workpiece have been carriedout. In this way, the parameters describing the deformationhistory of the elements have been determined as functions oftime. Experimentally obtained pre- and post deformation grainsize in the corresponding locations of the material weredetermined. It’s concluded that low temperature coupledwith high effective strain are conducive for obtaining a smallgrain size. Based on the beneficial conditions for extrusion ofcopper, a more detailed FE-analysis of a full-scale industrialprocess is carried out. A coarse-grained cast ingot of purecopper is heated and by upset forging formed into a cylinder,which is then punched into a hollow blank for subsequentextrusion. The blank is extruded over a mandrel through a45-degree semi-angle die. Accumulated effective strain andtemperatureas functions of the tubular wall thickness havebeen studied at five different locations along the tubularaxis. Forming load requirement as function of tool displacementfor each stage of the process has been determined. Strain andtemperature levels obtained have been related to the grain sizeinterval obtained in the earlier work. It has been concludedthat the levels reached are within the interval that ensures asmall grain size. A similar analysis has been carried out forforging of large copper lids and bottoms. Die designmodifications to improve the grain size in the lid and tooptimise the forging process with respect to forging load andmaterial yield have been proposed. A method requiring a smallforging load for fabrication of the lids has been analysed</p><p><b>Keywords:</b><i>Pores; grain size; low forging load; effective strain;temperature; hydrostatic pressure; extrusion; forging;canister; lid; rings</i></p>
635

Thermophoretic force measurements of spherical and non-spherical particles /

Zheng, Feng, January 2000 (has links)
Thesis (Ph. D.)--University of Washington, 2000. / Vita. Includes bibliographical references (leaves 111-116).
636

Project SHAPE : an experimental evaluation of a group versus computer-based intervention to improve food portion size estimation skills /

Ayala, Guadalupe Xochitl. January 2002 (has links)
Thesis (Ph. D.)--University of California, San Diego and San Diego State University, 2002. / Vita. Includes bibliographical references (leaves 242-255).
637

Preemptive power analysis for the consulting statistician novel applications of internal pilot design and information based monitoring systems /

Sawrie, David Franklin. January 2007 (has links) (PDF)
Thesis (Ph.D.)--University of Alabama at Birmingham, 2007. / Title from PDF title page (viewed on Feb. 19, 2010). Includes bibliographical references.
638

A microfluidic Coulter counting device for metal wear detection in lubrication oil

Veeravalli Murali, Srinidhi. January 2008 (has links)
Thesis (M.S.)--University of Akron, Dept. of Mechanical Engineering, 2008. / "December, 2008." Title from electronic thesis title page (viewed 12/9/2009) Advisor, Jiang John Zhe; Faculty Readers, Joan Carletta, Dane Quinn; Department Chair, Celal Batur; Dean of the College, George K. Haritos; Dean of the Graduate School, George R. Newkome. Includes bibliographical references.
639

Self-designing optimal group sequential clinical trials /

Thach, Chau Thuy. January 2000 (has links)
Thesis (Ph. D.)--University of Washington, 2000. / Vita. Includes bibliographical references (leaves 107-111).
640

Utvärdering av regnmätning och droppstorleksfördelning från en distrometer / Evaluation of Rain Measurement and Drop Size Distribution from a Disdrometer

Wennerdahl, Emelie January 2015 (has links)
Nederbördsmätning är viktigt inom många områden och en relativt ny teknik är enoptisk distrometer som med hjälp av laserteknik mäter nederbördspartiklarnasdroppstorlek och fallhastighet. Syftet med detta arbete var att undersöka hur välThies distrometer stämmer överens med nederbördsmätning från ett vippkärl ochmanuella mätningar från institutionen för geovetenskaper vid Uppsala universitet.Institutionen för geovetenskaper överväger att gå över till denna teknik och därmedbehövdes distrometern utvärderas för olika faktorer som kan påverka instrumentet.Vid jämförelse mellan instrumenten visade det sig att distrometern totalt sett samladein mer nederbörd än de andra mätarna. Det är svårt att avgöra vad skillnaden mellaninstrumenten kan bero på men felkällor så som avdunstning och vätning hos vippkärletoch manuella mätningar kan ge mindre nederbörd. En annan orsak kan varafelkalibrering av datan från distrometern. Inga samband hittades för vindhastighet,vindriktning och typ av nederbörd mellan de tre instrumenten. En vidare undersökning gjordes för droppstorleksfördelningen för att ge exempelpå fördelar med en distrometer. Droppstorleksfördelningen från distrometernjämfördes med exponentialfördelningen framtagen av Marshall &amp; Palmer (1948).Resultatet visade sig stämma överens med tidigare studier, fördelningen stämmerbra överens för stratiforma väder, men sämre för konvektiva och snö. / Measuring precipitation is important in many areas of research. A relatively newtechnology for measuring precipitation is the optical disdrometer, which measures thefalling velocity and drop size of particles by using lasers. The purpose of this workwas to compare data from a disdrometer with data from a tipping bucket and amanual measurement series from the Department of Earth Sciences at UppsalaUniversity. The comparison between the instruments showed that the disdrometermeasured more precipitation than the tipping bucket and the manual measurements.A reason for this can be due to evaporation and wetting from the tipping bucket andmanual measurement. Errors in calibration of data from the disdrometer may alsohave influence. Furthermore, an analysis of the drop size distribution was done in order todetermine areas of special use for the device. The drop size distribution calculatedfrom the distrometer was compared with the Marshall and Palmer (1948) distribution.The results showed that the MP-distribution was a good fit for stratiform weather;however, for convective clouds and snow the fit was not satisfactory and some otherrelationship should be used instead.

Page generated in 0.0511 seconds