• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1282
  • 19
  • 9
  • 1
  • Tagged with
  • 1312
  • 1312
  • 1036
  • 911
  • 227
  • 210
  • 193
  • 151
  • 127
  • 102
  • 88
  • 88
  • 81
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Modelagem numérica da interface tubulação/revestimento em poços de petróleo / Numerical simulation of tubing/coating interface in oil-wells

Neto, José Felix da Silva 13 August 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:42Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 4158784 bytes, checksum: 614ac248aca292bc7e1a840fb03f4a7f (MD5) Previous issue date: 2012-08-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Oil has become one of the greater sources of energy in the contemporary world and ensures that its extraction is done without loss of production wells and structurally reliable is essential. Cementitious coatings of oil wells are used in order to ensure structural support of the wells and corrosion protection. In these structures, the adhesion between steel and cementitious material is responsible for ensuring the mechanical and the thermodynamical efficiencies, protecting them against corrosion, preventing the escape of fluids inside and isolating the hydraulic structure against infiltrations. The push-out test is used to measure the adherence between steel and cement. In this work, the numerical simulation of steel-cement interface was carried. For reproducing the mechanical behavior of this interface, a cohesive-zone model, formulated from the perspective of Damage Mechanics, combined with Coulomb's law for friction were used. The proposed model was implemented in CAST3M software. The numerical results obtained with the proposed model were compared with experimental results of push-out tests made with three different interface conditions. The comparison between the force versus displacement curves obtained experimentally and numerically validated the proposed model. / O petróleo tornou-se uma das principais fontes de energia do mundo contemporâneo e garantir que sua extração seja feita sem que haja perdas de produção e com poços estruturalmente confiáveis é fundamental. Os revestimentos cimentícios dos poços de petróleo são utilizados no intuito de garantir suporte estrutural aos poços e proteção contra corrosão. Nessas estruturas, a adesão entre o aço e o material cimentício é responsável por garantir a eficiência tanto do ponto de vista mecânico, garantindo suporte estrutural, quanto da estabilidade termodinâmica dos aços, protegendo-os contra a corrosão, impedindo a fuga de fluidos de seu interior e isolando hidraulicamente a estrutura contra infiltrações. O ensaio de arrancamento, também conhecido como push-out test, é utilizado no intuito de mensurar o nível de aderência entre o aço e o cimento. Neste trabalho, a simulação numérica da interface aço-cimento foi realizada. Para a reprodução do comportamento mecânico desta interface, utilizou-se um modelo de zona coesiva formulado sob a ótica da Mecânica do Dano combinado com a lei de Coulomb para o atrito. O modelo proposto foi implementado no software CAST3M. Os resultados numéricos obtidos com o modelo proposto foram comparados com resultados experimentais de ensaios de arrancamento feitos com três diferentes condições de interface: Tubo de aço limpo e seco (LS), tubo de aço borrifado com solução de NaCl em água (NaCl) e tubo de aço revestido por um cimento geopolimérico (GEO). A comparação entre as curvas força versus deslocamento, obtidas experimentalmente e numericamente, validaram o modelo proposto.
302

Controle de vazão PID para sistemas de refrigeração por absorção com o par água-brometo de lítio / Pid flow control for absorption refrigeration systems with pair water lithium bromide

Cézar., Kleber Lima 30 July 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:43Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2758359 bytes, checksum: c74021a7f64457575b424f6ec8ce4f59 (MD5) Previous issue date: 2012-07-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This approach describes the development of a flow control system for absorption refrigeration units with the pair lithium bromide-water. This system will include refrigeration units that operate at negative pressure, where the measurement of flow by intrusive methods is not tolerated and the recirculation is promoted by low-power single-phase pumps, which require unconventional methods for shift rotations. For that, was achieved through theoretical and informational researches, a testing bench reproducing the conditions required for the flow of saline water-lithium bromide. The same was properly instrumented for monitoring and intervention devices, whose correct adjustment and configuration were observed according to the achievement of preliminary testing of the water. The interaction with the testing bench took place with the aid of a previous virtual instrument control, implemented in the graphical language LabVIEW (Laboratory Virtual Instrument Engineering Workbench), evidencing the communication and management of the devices mentioned. Then was implemented in the same language, a system of closed-loop control, with PID controller (Proportional-Integral-Derivative), whose first evaluation occurred by testing with water, which allowed attest to the flow control and become familiar with methods of tuning. After appropriate precautions, tests were conducted with the solution water-lithium bromide, from which was conducted the adaptations that culminated in the success of this approach. / A presente abordagem descreve o desenvolvimento de um sistema de controle de vazão para unidades de refrigeração por absorção com o par água-brometo de lítio. Este sistema contemplará unidades de refrigeração que operam a pressões negativas, onde a aferição de vazão por métodos intrusivos não é tolerada e a recirculação é promovida por bombas monofásicas de baixa potência, as quais exigem métodos não convencionais na alteração de suas rotações. Para tanto foi alcançada, mediante levantamento teórico e informacional, uma bancada experimental reproduzindo as condições necessárias ao escoamento da solução salina água-brometo de lítio. A mesma foi devidamente instrumentada por dispositivos de monitoramento e intervenção, cujo correto ajuste e configuração foram evidenciados segundo a consecução de testes preliminares para a água. A interação com a bancada experimental se deu com o auxílio de um prévio instrumento virtual de controle, implementado na linguagem gráfica labVIEW (Laboratory Virtual Instrument Engineering Workbench), constatando-se a comunicação e o gerenciamento dos dispositivos mencionados. Em seguida foi implementado, na mesma linguagem, um sistema de controle em malha fechada, de ação controladora PID (Proporcional-Derivativo-Integral), cuja primeira avaliação ocorreu mediante ensaios com água, os quais permitiram atestar o controle de vazão e familiarizar-se com os métodos de sintonia do controlador. Depois de tomadas as devidas precauções, foram realizados ensaios com a solução água-brometo de lítio, a partir dos quais efetivaram-se as adequações que culminaram no êxito da presente abordagem.
303

Estudo teórico e experimental do calor específico e da cinética de sorção em reator fixo / THEORETICAL AND EXPERIMENTAL STUDY OF THE SPECIFIC HEAT AND THE SORPTION KINETICS IN FIXED REACTOR.

Amorim., Joselma Araújo de 13 April 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:43Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3231556 bytes, checksum: dbeb38d3575cc8d87938d6de158f2b05 (MD5) Previous issue date: 2012-04-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work has as objective to realize out a theoretical and experimental study of the specific heat and the sorption kinetics in a fixed reactor. The specific heat experiment was conducted at materials laboratory at UFPB and experimental bench of the kinetic of sorption in fixed reactor was mounted in the solar energy laboratory, both located in the city João Pessoa. The experimental apparatus consisting of fixed bed filled with silica gel and subjected to a flow of moist air. For the theoretical study realized in a fixed bed, was developed a computer code with the purpose of identifying various physical and geometrical parameters, which could influence the dynamics of sorption, allowing simulating the processes of dehumidification and regeneration in fixed beds. The computational code was validated comparing the numerical results with experimental results. Studies were also performed to determine the specific heat in the adsorbed phase using the DSC method and from these results, it was determined an equation general through least squares regression for the calculation of the specific heat in the adsorbed phase. The Results were presented about pressure drop in the adsorptive bed, the mass profile of adsorbed to investigate the time of saturation of the bed, the temperature profiles and absolute humidity at the output of a fixed bed and also the experimental results of the specific heat the adsorbed phase with various concentrations . With this study we can conclude that the computer code developed is an important tool for the design of fixed bed adsorption, because without this tool would require a very high cost to modify the configuration in a fixed bed, defining a better choice of experimental setup. / O presente trabalho tem como objetivo realizar um estudo teórico e experimental do calor específico e da cinética de sorção em reator fixo. O experimento do calor específico foi realizado no laboratório de materiais da UFPB e a bancada experimental da cinética de sorção em reator fixo foi montada no Laboratório de Energia Solar (LES), ambos, localizados na cidade de João Pessoa. O aparato experimental consiste em um leito fixo preenchido com sílica gel e submetido a um fluxo de ar úmido. Para o estudo teórico realizado no leito fixo, foi desenvolvido um código computacional com o intuito de se verificar diversos parâmetros físicos e geométricos, que poderiam influenciar na dinâmica de sorção, permitindo simular processos de desumidificação e regeneração em leitos fixos. O código computacional desenvolvido foi validado, comparando-se os resultados obtidos numericamente com os resultados experimentais. Foram também realizados estudos para determinar o calor específico na fase adsorvida utilizando o método DSC e a partir desses resultados, determinou-se uma equação geral através de uma regressão por mínimos quadrados, para o cálculo do calor específico na fase adsorvida. Foram apresentados resultados da perda de carga no leito adsortivo, perfis de massa adsorvida para investigar o tempo de saturação do leito, perfis de temperatura e umidade absoluta na saída do leito fixo, como também, resultados experimentais do calor específico na fase adsorvida com várias concentrações. Com este estudo podê-se concluir que o código computacional desenvolvido é uma ferramenta importante para o dimensionamento de leitos fixos adsortivos, pois sem esta ferramenta seria necessário um custo muito alto para modificar a configuração no leito fixo, podendo-se com ele definir uma melhor opção de montagem experimental.
304

Análise numérica da integridade estrutural de vasos de pressão com corrosão usando a Norma API 579. / Numerical analysis of the structural integrity of pressure vessels with corrosion using the standard API 579.

Almeida, Jayann Ismar Lira 06 November 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:44Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 3775255 bytes, checksum: 1b99107cee89e4bce6bbab2b485dac91 (MD5) Previous issue date: 2012-11-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Fitness-for-service (FFS) assessment is a quantitative engineering evaluation of operational components. In the context of pressure vessels and piping systems FFS assessment is performed periodically to ensure the operational safety and structural integrity. The evaluation of structural integrity of equipment is crucial to avoid failure and thereby obtain the best possible performance of mechanical components under corrosion, in turn, is one of the greatest dangers to pressure vessels. The evaluation of structural integrity of a component service that contains general damage or failure is given in Level 4 described in API 579. Nondestructive testing by ultrasound was used to obtain measurements of the loss of thickness wall of the pressure vessel for the model developed to numerical analysis using finite element. The objective is to analyze and evaluate the values of Maximum Allowable Working Pressure (MAWP) provided by the Fitness for Service assessment with the values found in numerical analysis. Results of PMTA are compared when it takes into account several variables that API 579 considers, the Future Corrosion Allowance (FCA) due to evolution of corrosion, the thickness uniform loss (LOSS) of the internally corroded areas and the changes of temperature affecting the structural integrity of the equipment. / A avaliação da integridade estrutural de equipamentos é de fundamental importância para se evitar falhas e assim obter o maior rendimento possível dos componentes mecânicos presente em vários setores industriais e a corrosão, por sua vez, constitui um dos maiores perigos para os vasos de pressão. A capacidade de analisar a integridade estrutural de um componente em serviço que contém danos ou falha é apresentada na norma API 579 (FFS - Fitness for Service). Utilizando o ensaio por ultrassom para obter medições de perda de espessura na área sob corrosão da parede de vasos de pressão e aplicando a análise da API 579 seção 4 que recomenda a adequação ao uso do equipamento com a presença de perda de metal generalizada, faz-se uma correlação com a análise numérica utilizando elementos finitos do vaso com a mesma área de corrosão obtida do ensaio de ultra-som. O objetivo é analisar e avaliar os valores de Pressão Máxima de Trabalho Admissível (MAWP - Maximum Allowable Working Pressure) fornecida pela API 579 para adequação ao uso do equipamento com os valores encontrados na análise numérica. Resultados de valores da MAWP são comparados quando leva-se em consideração algumas variáveis que a API 579 considera como, a perda de espessura futura (FCA - Future Corrosion Allowance) devido a evolução da corrosão, a perda de espessura unifome (LOSS) da área corroída internamente e mudanças de temperaturas que afetam a integridade estrutural desses equipamentos.
305

Análise estática de dutos enterrados pelo acoplamento entre o método dos elementos finitos e o método dos elementos de contorno. / Static analysis of buried pipes using coupling between finite element method and boundary element method.

Menezes Junior, Raimundo Aprigio de 30 October 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:44Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 3772690 bytes, checksum: e032df086ce22dd8ceaa668979d9ed25 (MD5) Previous issue date: 2012-10-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work deals with the analysis of soil-structure interaction modeling of pipeline problems in static behavior using the coupling between Finite Element Method (FEM) and Boundary Element Method (BEM).The representation of the pipe is made by MEF using two finite elements in the cylindrical panel: The first, formulated from the classical theory of cylindrical shells by assumptions of Donnel and initially proposed by Djoudi & Bahai, using the Assumed Strain Based Model. The second formulated from the theory of equivalent discrete layers (Layerwise Theory), proposed by J. N. Reddy. The soil is represented by elastic continum infinite or semi-infinite and modeled using boundary elements with special curved surface, associated with cylindrical panel, used to represent the soil-structure interaction within the soil, especially at the contact surface with the pipe. Besides the mathematical representation of the model, this work propose a library DLL (Dynamic Link Library) written using the object-oriented programming (OOP) for processing soil structure interaction problems and a user-friendly environment built using the ObjectARX library for customizing AutoCAD. / Neste trabalho aborda-se a análise da interação solo-estrutura para modelagem de problemas de dutos em regime estático através do acoplamento entre o método dos Elementos Finitos (MEF) e o método dos elementos de contorno (MEC). A representação do duto homogêneo ou laminado é feita pelo MEF utilizando-se dois elementos finitos na forma de um painel cilíndrico: O primeiro foi desenvolvido a partir do modelo isotrópico homogêneo proposto inicialmente por Djoudi e Bahai, que utiliza a filosofia do modelo de deformações assumidas (Assumed Strain Based Model). O segundo foi proposto por Reddy e é baseado na teoria de camadas equivalentes discretas (Layerwise Theory). O solo é admitido ser um contínuo elástico infinito ou semi-infinito e modelado pelo MEC onde elementos de contorno especiais são propostos com superfície curva ou bordos curvos para representar a interação solo-estrutura principalmente nas superfícies de contato com o duto. Além da representação matemática do modelo da interação solo-estrutura, é proposta uma biblioteca DLL (Dynamic Link Library) escrita utilizando-se a filosofia de programação orientada a objetos (POO) para o processamento de problemas de interação solo estrutura e um ambiente amigável ao usuário construído a partir da biblioteca ObjectARX para customização do AutoCAD.
306

Modelo computacional de otimização para dimensionamento de redes de distribuição de água abastecidas por múltiplos bombeamentos. / Computational model of optimization for sizing of water distribution networks supplied by multiple pumping.

Gouveia, Roberta Macêdo Marques 20 September 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:45Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 7182461 bytes, checksum: a98f0cc042311821ced96a1784670e80 (MD5) Previous issue date: 2012-09-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The high costs involved in water distribution systems, particularly with regard to the design and operation thereof, reflect the importance of studying ways to minimize the loss of water and electricity, in order to increase the efficiency of these systems. In an attempt to minimize and avoid such loss, This study commit to investigate and propose a model optimized sizing of networks, with emphasis on hydraulic efficiency, energy and economic. The main objective is to minimize system costs, understood by the network pipe costs, the energy of pumping main (main system of impulsion) and the energy of pumping secondary, represented by boosters. The proposed methodology for the sizing considers the energy costs of multiple pumping, plus the cost of implantation of the pipes. Using this methodology it is possible to achieve a design with lower pressures and longer appropriate, with consequent reduction in energy and water losses throughout the system. To achieve the proposed objectives, the methodology used in this study comprehend an iterative algorithm and dynamic of optimization. The said algorithm originated the program Toolkit of Sizing Optimized (TDO), that have been implemented using the EPANET Programmer's Toolkit. To validate the theory, case studies were conducted with three water distribution networks: network Grande Setor Expanded , network R9 Adapted and network Hanoi The results obtained, using the TDO, demonstrate that the sizing most suitable for operation of the networks studied were obtained using sectorization, through the inclusion of secondary pumping. / Os altos custos envolvidos nos sistemas de distribuição de água, particularmente no que diz respeito aos projetos e operação dos mesmos, refletem a importância de se estudar meios de minimizar os desperdícios de água e energia elétrica, a fim de elevar a eficiência desses sistemas. Na tentativa de minimizar e evitar tais desperdícios, este trabalho empenha-se em investigar e propor um modelo de dimensionamento otimizado de redes, com ênfase na eficiência hidráulica, energética e econômica. O principal objetivo é minimizar os custos do sistema, compreendido pelos custos das tubulações da rede, da energia do bombeamento principal (sistema principal de impulsão) e da energia dos bombeamentos secundários, representados por boosters. A metodologia proposta para o dimensionamento considera os custos energéticos dos múltiplos bombeamentos, além do custo de implantação das tubulações. Com o emprego desta metodologia pode-se alcançar um dimensionamento com pressões menores e mais adequadas, com a consequente diminuição das perdas de água e energia em todo o sistema. A fim de alcançar os objetivos propostos, a metodologia empregada neste trabalho compreende um algoritmo iterativo e dinâmico de otimização. O referido algoritmo deu origem ao programa Toolkit de Dimensionamento Otimizado (TDO), tendo sido implementado utilizando o toolkit de programação do simulador hidráulico EPANET 2.0. Para validar o trabalho, realizaram-se alguns estudos de casos com três redes de distribuição de água: rede Grande Setor Expandida, rede R9 Adaptada e rede Hanoi. Os resultados alcançados, pelo TDO, demonstram que os dimensionamentos mais adequados para operação das redes estudadas foram obtidos com a setorização, por meio da inclusão dos bombeamentos secundários.
307

Utilização das equações de Navier Stokes com a parametrização convectiva BMJ para prognóstico de temperatura, umidade e vento sobre diferentes condições de estabilidade atmosférica utilizando o modelo regional ETA / Use of the Navier - Stokes BMJ with convective parameterization for forcast temperature, moisture and wind on different conditions of atmospheric stability using ETA regional model

Araújo, Janduy Guerra 26 October 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:46Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2136442 bytes, checksum: 3d0ee50f2ecd5dc62121187d1ce4c080 (MD5) Previous issue date: 2012-10-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Here an approach is made on the impact of convective parameterization Bettes - Miller - Janjic (BMJ) on temperature, moisture and wind predicted by the model ETA. There are several papers in the literature that focus on this topic, few directed in particular to the state of Paraiba, but none of them uses the methodology described herein. It is known that below the cloud base (850hPa) profiles of temperature and moisture are not affected by the BMJ parameterization scheme because it does not consider the downdrafts of cold air to lower levels. Given this assumption, the methodology implemented in this work is to compare temperature, moisture and wind series provided by ETA with the respective synoptic analyzes of convective ERA-INTERIM/ECMWF for two contrasting situations. The model was configured with a horizontal resolution of 12 km and 30 vertical levels, covering the northeastern Brazil and the adjacent Atlantic and the focus of analysis is for three cities in the state of Paraiba. The results revealed that the predicted temperature to Joao Pessoa was slightly underestimated for low levels, while for the other two cities the model significantly overestimated the temperature at 1000 mb and slightly underestimated in 900 and 800mb. The predictions of moisture and wind were considered satisfactory when compared with the Analysis, and the best results were found at low levels. There were no significant differences between the estimates in both contrasting situations. / Nesta pesquisa é feita uma abordagem sobre o impacto da parametrização convectiva de Bettes Miller Janjic (BMJ) na temperatura, umidade e vento prognosticados pelo modelo ETA. Há vários trabalhos na literatura que focalizam este tema, poucos direcionados, em particular, para o estado da Paraíba, mas nenhum deles usa a metodologia descrita neste. É sabido que abaixo da base da nuvem (850hPa) os perfis de temperatura e umidade não são afetados pelo esquema de parametrização BMJ, pois ele não considera as correntes descendentes de ar frio para os baixo níveis. Diante deste pressuposto, a metodologia executada neste trabalho consiste em comparar as séries de temperatura, umidade e vento previstas pelo ETA com os respectivos dados sinóticos das análises do ERA-INTERIM/ECMWF para duas situações convectivas contrastantes. O modelo foi executado com resolução horizontal de 12 km e 30 níveis verticais, cobrindo o nordeste brasileiro e Oceano Atlântico adjacente e o foco das análises é para três cidades do estado da Paraíba. Os resultados revelaram que a temperatura prevista para João Pessoa foi ligeiramente subestimada para baixos níveis, enquanto que para as outras duas cidades o modelo superestimou significativamente a temperatura em 1000 mb e ligeiramente subestimou em 900 e 800mb. Os prognósticos de umidade e vento foram considerados satisfatórios quando comparados com as Analises, sendo que os melhores resultados foram encontrados em baixos níveis. Não houve diferenças significativas entre as previsões nos dois períodos analisados.
308

Obtenção e evolução da fase icosaedral quasicristalina em ligas Al-Cu-Fe e Al-Cu-Fe-B por Melt-Spinnin / OBTAINING AND EVOLUTION OF PHASE ICOSAHEDRAL QUASICRISTALINA IN ALLOYS Al-Cu-Fe AND Al-Cu-Fe-B BY MELT-SPINNING

Feitosa, Francisco Riccelly P. 03 March 2009 (has links)
Made available in DSpace on 2015-05-08T14:59:46Z (GMT). No. of bitstreams: 1 parte1.pdf: 1839351 bytes, checksum: 34e86046fc8cf8f52125675d2e7267f6 (MD5) Previous issue date: 2009-03-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Melt spinnng processing is one of the most common processes to obtaining quasicrystaline structures. This is because of the fast cooling rate it imposes on the system, favoring such type of structure. This work deals with the production of quasycristaline phases (Al60Cu27,5Fe12,5 e Al57Cu27,5Fe12,5B3) via melt-spinning. The alloys were initially cast via induction melting under atmospheric air, with the designed chemical composition of the quasicrystals. Hence, the ribbons were produce by melt-spinning were characterized by means of x-ray diffraction and scanning electron microscopy. The results indicate that the icosahedral ψ - Al65Cu20Fe15 phase formed in both types of starting compositions. It seams that the boron contributes to stabilize the icosahedral phase. / O processo melt-spinning por imprimir altas taxas de resfriamento, é um dos principais meios para a obtenção de ligas com estrutura quasicristalinas, sendo o primeiro método utilizado para produzir materiais quasicristalinos. Neste trabalho utilizou-se este processo para a elaboração das ligas quasicristalinas Al(60-x)Cu25Fe15Bx, Al(60-x)Cu27,5Fe12,5Bx e Al(65-x)Cu20Fe15Bx (x=0 e x=3%at de boro). As ligas foram previamente fabricadas, por fusão, em atmosfera de argônio, em forno à indução, para em seguida serem submetidas ao processo melt-spinning , onde se obteve o material na forma de fita. As amostras foram caracterizadas por difração de raios-x e microscopia eletrônica de varredura. Os resultados indicaram a formação da fase icosaedral ψ - Al65Cu20Fe15 nas composições estudadas e uma provável contribuição do boro na produção dessa fase icosaedral
309

Estudo experimental e teórico de um resfriador de água por adsorção usando energia solar / Experimental and theoretical study of an adsorption chiller water by using solar energy

Vieira, Herbert Melo 25 March 2013 (has links)
Made available in DSpace on 2015-05-08T14:59:46Z (GMT). No. of bitstreams: 1 ArquivoTotal.pdf: 9428315 bytes, checksum: 48c140981cf20867371ca9c0ebfcfec7 (MD5) Previous issue date: 2013-03-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The respective thesis aims to develop a cooling system that uses an adsorptive chiller for cooling water and subsequent use of this cold water for air conditioning environment, theoretically and experimentally verifying the performance of adsorption refrigeration system, these devices have several advantages, among them, the use of clean energy such as solar. Brazil is a country with high rates of stroke, with an average capacity 16-20 MJ / year / h, so it becomes quite conducive to harnessing this energy, and to be contributing to the reduction of fossil fuel consumption and reduction of harmful gases to the environment. The proposed system consists of flat solar collectors, which are used to convert solar energy into thermal, being last transferred to a heat transfer fluid that circulates through the collector which is then stored in a boiler, or a thermal fluid, to be used whenever required for heating the bed adsorptive a chiller, which is composed of bed adsorptive the finned annular ducts involved with the adsorbent (silica gel). Many studies have been developed with the aim of increasing the performance of these systems, these studies have focused primarily on increasing the mass transfer and heat of adsorption beds and using systems which run continuously through the use of two adsorption beds which work in different phases. Experimental studies in porous beds featuring different configurations were performed, observing thus which present higher rates adsorbent, and subsequently applied this setting in the construction of the porous bed adsorptive chiller. A computational model was developed theoretically allowing you to check your system's performance. / O respectivo trabalho de tese visa desenvolver um sistema de refrigeração que utiliza um chiller adsortivo para resfriamento de água e posterior uso desta água fria para climatização de ambiente, verificando teoricamente e experimentalmente o desempenho do sistema de refrigeração por adsorção, estes dispositivos apresentam várias vantagens, entre elas, o uso de energia limpa, como a solar. O Brasil é um país que apresenta grande índice de insolação, com uma capacidade média de 16 a 20 MJ/ano/h, desta forma torna-se bastante propício o aproveitamento desta energia, além de estar contribuindo para a redução do consumo de combustíveis fósseis e redução de gases nocivos ao meio-ambiente. O sistema proposto é composto por coletores solares planos, que são usados para converter a energia solar em térmica, sendo está última transferida para um fluido térmico que circula pelo coletor que posteriormente é armazenado em um boiler, podendo este fluido térmico, ser usado sempre que necessário para o aquecimento do leito adsortivo de um chiller, sendo este leito adsortivo composto por dutos aletados na forma anular envolvidos com o adsorvente (sílica gel). Muitos trabalhos vem sendo desenvolvidos com o intuito de aumentar o desempenho destes sistemas, estes estudos estão concentrados basicamente no aumento da transferência de massa e calor dos leitos adsortivos e utilização de sistemas que funcione continuamente através do uso de dois leitos adsortivos que trabalham em fases diferentes. Ensaios experimentais com leitos porosos apresentando configurações diferentes foram realizados, observando deste modo, qual apresentaria maiores taxas adsortivas, sendo posteriormente aplicada esta configuração na construção do leito poroso do chiller adsortivo. Um modelo computacional foi desenvolvido permitindo verificar teoricamente o desempenho do sistema.
310

Estimação das propriedades termofísicas de leite integral através da técnica analítico-experimental. / Estimation of whole milk thermophysical properties by experimental-analytical technique

Oliveira, Edilma Pereira 31 July 2013 (has links)
Made available in DSpace on 2015-05-08T14:59:47Z (GMT). No. of bitstreams: 1 ArquivoTotalEdilma.pdf: 3342457 bytes, checksum: ab038da16334ba7acdbbca9aab59c08b (MD5) Previous issue date: 2013-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The estimation of the thermodynamic and transport properties have been studied by many researchers due to the need to input data in calculations and optimization equipment projects that involve adding and removing energy. Transient methods are widely used for determination of thermal transport properties. Usually, these methods are used in homogeneous materials to measure various thermophysical properties, simultaneously or separately. This work deals with the solution of an inverse problem, to estimate thermal properties parameters of whole milk. The direct problem is solved analytically using the Classical Integral Transform Technique (CITT). The proposed algorithm allows the estimation of the thermal conductivity at the interface of a medium composed of three layers through measurements of temperature distribution in one surface, resulting from a transient thermal pulse on the opposite surface. The thermal perturbation of the sample was done using a device known as micro flash LFA model 457, manufactured by Netzsch. The results are shown in terms of thermal diffusivity and thermal conductivity and are compared with values available in the literature for products of the same nature, thus providing thermal properties data of whole milk to be applied in dimensioning calculations of industrial processes. / A estimação das propriedades termodinâmicas e de transportes tem sido objeto de estudo de diversos pesquisadores devido à necessidade de seu conhecimento para alimentar os códigos de cálculos de otimização e projetos de equipamentos que envolvam adição e remoção de energia. Métodos transientes são largamente utilizados para determinação de propriedades térmica de transporte. Normalmente estes métodos são usados em meios homogêneos para mensurar várias propriedades termofísicas, simultaneamente ou separadamente. A análise de materiais compostos de múltiplas camadas é mais complicada. O algoritmo proposto permite a estimativa da difusividade térmica na interface de um meio composto de três camadas através da medida da distribuição detemperatura transiente resultante de um pulso térmico na superfície oposta. Esse trabalho trata da solução de um problema inverso de estimação de parâmetros para estimar as propriedades térmicas de produtos lácteos. O problema direto é resolvido analiticamente utilizando a Técnica da Transformada Integral Clássica (CITT). O procedimento experimental consiste de submeter as amostra de produtos lácteos confinada em uma cavidade cilíndrica a uma perturbação térmica de curta duração em uma das faces (anterior) e medir a evolução da temperatura transiente na outra face (face posterior). Para a perturbação térmica da amostra foi utilizado um dispositivo, denominado de micro-flash, modelo LFA 457, fabricado pela Netzsch. O pulso de curta duração é originário de um sistema de potencia que libera uma energia equivalente a 15 Joules por pulso e registra a evolução da temperatura através de um sensor infravermelho, tipo InSb-IR. Esseequipamento dispõe de um sistema de geração de pulso laser. Os resultados são mostradosem termos da difusividade térmica e da condutividade térmica e são comparados com osvalores disponíveis na literatura para produtos da mesma natureza.

Page generated in 0.0205 seconds