• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicación de espectroscopía de masas (Esi-Tof/MS) al estudio de polímeros inorgánicos de aluminio involucrados en la nucleación y crecimiento de nanopartículas ambientales de hidrobasaluminita

Moraga Garay, Sergio Danilo January 2016 (has links)
Geólogo / La nanogeociencia así como la mineralogía ambiental son áreas de investigación que gracias a nuevos avances tecnológicos se están expandiendo rápidamente en múltiples direcciones enfocadas en la detección, caracterización y comprensión de fases no cristalinas, pobremente cristalinas y fases mixtas amorfo-cristalinas, así como también materiales nanométricos. En este contexto, los procesos no clásicos de nucleación y crecimiento cristalino presentes en soluciones acuosas representan un campo emergente que surge como alternativa al enfoque clásico con el cual ha sido abordado este tema (diferentes etapas de unión de monómeros básicos -átomos, iones o moléculas- entre sí). Estos procesos utilizan polímeros y nanopartículas más pequeñas como unidades básicas precursoras del crecimiento cristalino. La formación de nanopartículas de aluminio (comunes tanto en entornos naturales como procesos industriales), y más concretamente la precipitación de hidrobasaluminita (Al4SO4(OH)10 · 12-36H2O), puede ser considerada como el proxy perfecto para el estudio de estos procesos no clásicos. Para caracterizar las especies poliméricas generadas durante la síntesis acuosa de nanopartículas de hidrobasaluminita la metodología utilizada en este trabajo es el análisis mediante ionización por electrospray acoplada a un espectrómetro de masas de tiempo de vuelo (ESI-TOF/MS). Esta técnica fue aplicada a cuatro soluciones de Al2(SO4)3 · 18H2O resultando en la identificación de 38 especies poliméricas catiónicas, ratificando la utilidad de esta técnica en el estudio de estos procesos no clásicos de cristalización permitiendo generar un primer volumen de datos para la elaboración de una base de datos con la masa y la fórmula de los polímeros de aluminio más comunes detectados en el sistema acuoso Al-S-O-H. Los resultados mostraron una especiación variable, donde las especies reconocidas abarcan polímeros basados en Al, Al2, Al3, Al4, Al5, Al6 y algunos más complejos como Al11 o Al13. Dentro de los parámetros estudiados el efecto del pH fue el más notable de todos. Observándose una clara dependencia de este factor en la formación de complejos de mayor tamaño y carga. Por otra parte, la concentración de Al en la solución también mostró injerencia sobre la especiación de las muestras. Finalmente, la metodología y resultados obtenidos, a pesar de las limitaciones asociadas, permiten acercarse a una caracterización más certera de los procesos que rigen la precipitación de hidrobasaluminita y la naturaleza de las especies que participan en éstos.
2

LC-ESI-TOF-MS Analysis of the Polar Metabolome of Sinorhizobium Meliloti

Deglint, Elna Dawn 09 1900 (has links)
The goal of this thesis is to determine if Sinorhizobium meliloti can be useful as a sentinel soil microorganism for assessing the impacts of contaminant stressors on the metabolome of a microorganism. Not only is a good deal known about this organism, but it is an important organism in agriculture. Moreover, the currently available gene array and a large library of gene fusion can be used as facile pathways to explore genetic and genomic impacts in addition to metabolomic impacts of contaminants, should such studies be deemed worthwhile. In this study, the polar metabolome of the soil microorganism, Sinorhizobium meliloti, has been analyzed by LC-ESI-MS using a HILIC column coupled to a medium mass resolution time-of-flight mass spectrometer. This approach has resulted in the retention (k' > 0.7) of over 300 polar metabolites as detected in both positive ion and negative ion modes. These data do not include ions corresponding to adduct ions, isotopic features or ions resulting from in-source decay processes. The retained peaks showed excellent linear responses and did not suffer from ion suppression, a common problem in flow-injection ESI analysis. This methodology has been applied to the analysis of S. meliloti exposed to fluorene, a common PAH contaminant, and to a coal tar fraction containing low molecular mass PAHs. Multiple cultures of S. meliloti were grown on M9 glucose minimal medium in the absence and presence of fluorene (0.14 mg/L and 1.4 mg/L) and a PAH mixture (total PAH concentrations of 0.14 mg/L and 1.4 mg/L). Analyses of biological replicates were performed in pentuplicate. The retention times of the resulting chromatograms were aligned, peak areas determined and the resulting data processed using PCA and OPLS-DA methods. The retention time reproducibilities of peaks were within ± 10 seconds and the biological variabilities of over 700 components averaged 23% ± 15% (n=25) . The impacts of fluorene exposures and PAH mixture exposures on the S. meliloti metabolomes (polar) caused significant changes in the metabolome. The lower concentration exposures had less of an impact than the higher dosages. Low dosages of both fluorene and the PAH mixture produced a similar metabolic response in S. meliloti, while at higher dosages the responses were more specific to each toxin. The use of SUS plots coupled with S-plots of the OPLS-DA analysis were particularly advantageous for the identification of metabolites of interest. Changes were seen in the levels of adenine, adenosine, glutamate, and aspartate, among others. In the future, the profiles of the non-polar metabolites of each of sample will be analyzed using a previously developed 'shotgun lipidomics' method. / Thesis / Master of Science (MS)
3

Développement et évaluation d’une méthode LC-MS/MS pour l’analyse de résidus de tir en criminalistique/Development and assessment of a LC-MS/MS method for the analysis of gunshot residues in criminalistics

Laza, Désiré 16 February 2007 (has links)
Ce travail de thèse rentre dans le cadre d’un projet de recherche appliquée mené à l’Institut National de Criminalistique et de Criminologie s’intitulant « développement d’un système intégral de détection et d’identification de résidus de tir » visant à doter le laboratoire de balistique chimique d’un outil performant pour la recherche et la caractérisation des résidus de tir aussi bien inorganiques qu’organiques. Comme nous l’expliquons dans le chapitre 1, l’analyse des résidus de tir est aujourd’hui essentiellement basée sur la mise en évidence par microscopie électronique à balayage des particules métalliques provenant de l’amorce. Cette pratique a des limites. Introductif, ce chapitre met en lumière la relation entre criminologie et criminalistique, donne un aperçu de la classification des armes et décrit les relations entre les armes de poing, les munitions, les résidus de tir et la criminalistique. La motivation de l’analyse de résidus organiques et plus particulièrement des stabilisants pour poudres propulsives y est aussi expliquée. Le but principal de ce travail étant le développement d’une méthode d’analyse des stabilisants par spectrométrie de masse en tandem couplée à la chromatographie liquide à haute performance (LC-MS/MS), ce premier chapitre aborde de façon détaillée le principe de fonctionnement d’un spectromètre de masse quadripolaire, qu’il soit avec simple quadripôle ou en tandem, et traite avec une attention particulière les aspects relatifs à la production d’ions, l’acquisition des données et la détection des ions. Le chapitre 2 est consacré aux résultats et discussions. Comme point de départ de tous les travaux ultérieurs, l’optimisation du fonctionnement du spectromètre et plus particulièrement la détermination des « ions précurseurs » et des « ions produits » y est traitée en détails. De plus, l’étude de la fragmentation des ions précurseurs y occupe une place prépondérante et conditionne l’établissement d’une méthode de détection et d’acquisition des données. Dans ce même chapitre sont successivement traités la mise au point de la méthode chromatographique pour l’analyse des stabilisants par LC-MS/MS, le couplage LC-MS/MS, la collecte et préparation des échantillons, dont l’extraction sur phase solide (SPE). Disposant des procédures de traitement des échantillons et d’une méthode LC-MS/MS, il nous a été possible de mener l’étude de faisabilité de l’analyse des stabilisants dans les échantillons prélevés sur les mains d’un tireur. Cette étude fait l’objet d’une proposition de publication jointe en annexe. Pour être exploitable en criminalistique, ce travail est complété par une étude sur les fréquences d’observation des stabilisants pour poudres propulsives sur les mains des non-tireurs. L’ensemble des résultats nous permet de dresser un bilan et proposer des perspectives décrites dans le chapitre 3. A cet égard, nous proposons de poursuivre les essais relatifs aux tests de persistance des résidus de stabilisant sur les mains des tireurs et d’entamer une étude sur la caractérisation des résidus de tir de la nitrocellulose. Du point de vue de l’exploitation des acquis de ce travail, nous suggérons que les méthodes et procédures développées soient mises à l’épreuve dans les affaires nécessitant l’analyse des prélèvements effectués sur les vêtements d’un suspect ou d’une victime. Cette mise à l’épreuve permettra de comparer l’efficacité de la méthode LC-MS/MS à celle de la technique SEM/EDX habituellement utilisée. Le chapitre 4 est consacré aux matériels et méthodes détaillant notamment les procédures de collectes et de traitement des échantillons, les paramètres de fonctionnement du spectromètre de masse et les méthodes analytiques. <br> <br> This thesis deals with a research project entitled "Development of an integral system of detection and identification of gunshot residues”, carried out at the Belgian National Institute of Criminalistics and Criminology (NICC). This project aims at providing the Laboratory of Chemical Ballistics, a powerful tool to detect and identify organic gunshot residues. For instance, the analyses of gunshot residues is presently performed mainly for characterizing metallic particles originating from the primer, using scanning electron microscopy coupled to energy dispersive X-ray microanalysis (SEM-EDX). However this technique has its limits and the goal of the thesis was the development of a method for the analysis of the stabilizers (and their derivatives) present in propellant powders with the use of tandem mass spectrometry coupled to high performance liquid chromatography (LC-MS/MS). The introduction highlights the relations between Criminology and Criminalistics; it gives an outline of the classification of weapons, and describes how handguns, ammunitions, gunshot residues and Criminalistics can be linked when investigating criminal cases. The motivation of the analysis of organic gunshot residues and in particular the propellant powder stabilizers is also explained. Chapter 1 deals in detail with the working principle of a quadrupole mass spectrometer, whether it is with a single quadrupole or composed of a tandem mass spectrometer. Important aspects connected with the ion production, the data acquisition and the ion detection are also considered. Chapter 2 presents the results and discussions. It begins with the optimization of the operating conditions of the spectrometer, and focuses more specifically on the determination of “precursor ions" and "daughter ions”. The study of the precursor ion is more important because it is required for the choice of parameters involved in the data acquisition mode. The development of a liquid chromatography (LC) method and the procedures for collecting and preparing the samples are explained. Moreover, Chapter 2 summarizes the results of a feasibility study of the analyses of stabilizers in samples collected from the hands of a shooter. This study was published in a peer reviewed journal [1]. A complementary study on the frequencies of observation of stabilizers on the hands of non-shooter persons is reported at the end the Chapter. The results allow also proposing perspectives which are described in Chapter 3. In this respect, the characterization of nitrocellulose residues and the study of the persistence of stabilizer residues on the hands of shooters should be undertaken. From the practical point of view, the developed methods and procedures should be tested in real cases which involve the analyses of the samples taken from the clothing of suspects and/or victims. These tests should allow an assessment of the LC-MS/MS method compared to the efficiency of the SEM/EDX technique currently used. Chapter 4 is dedicated to the materials and methods; the sample collection and treatment procedures, as well as the working parameters of the mass spectrometer and the analytical methods are explained in detail. [1]. Désiré Laza, Ph.D.; Bart Nys, Ph.D.; Jan De Kinder, Ph.D.; Andrée Kirsch - De Mesmaeker, Ph.D.; and Cécile Moucheron, Ph.D. Development of a Quantitative LC-MS/MS Method for the Analysis of Common Propellant Powder Stabilizers in Gunshot Residue. J. Forensic Sci, July 2007, Vol. 52, N° 4, 842-850.
4

Développpement et évaluation d'une méthode LC-MS/MS pour l'analyse de résidus de tir en criminalistique / Development and assessment of a LC-MS/MS method for the analysis of gunshot residues in criminalistics

Laza, Désiré 16 February 2007 (has links)
Ce travail de thèse rentre dans le cadre d’un projet de recherche appliquée mené à l’Institut National de Criminalistique et de Criminologie s’intitulant « développement d’un système intégral de détection et d’identification de résidus de tir » visant à doter le laboratoire de balistique chimique d’un outil performant pour la recherche et la caractérisation des résidus de tir aussi bien inorganiques qu’organiques. Comme nous l’expliquons dans le chapitre 1, l’analyse des résidus de tir est aujourd’hui essentiellement basée sur la mise en évidence par microscopie électronique à balayage des particules métalliques provenant de l’amorce. Cette pratique a des limites. Introductif, ce chapitre met en lumière la relation entre criminologie et criminalistique, donne un aperçu de la classification des armes et décrit les relations entre les armes de poing, les munitions, les résidus de tir et la criminalistique. La motivation de l’analyse de résidus organiques et plus particulièrement des stabilisants pour poudres propulsives y est aussi expliquée. Le but principal de ce travail étant le développement d’une méthode d’analyse des stabilisants par spectrométrie de masse en tandem couplée à la chromatographie liquide à haute performance (LC-MS/MS), ce premier chapitre aborde de façon détaillée le principe de fonctionnement d’un spectromètre de masse quadripolaire, qu’il soit avec simple quadripôle ou en tandem, et traite avec une attention particulière les aspects relatifs à la production d’ions, l’acquisition des données et la détection des ions.<p>Le chapitre 2 est consacré aux résultats et discussions. Comme point de départ de tous les travaux ultérieurs, l’optimisation du fonctionnement du spectromètre et plus particulièrement la détermination des « ions précurseurs » et des « ions produits » y est traitée en détails. De plus, l’étude de la fragmentation des ions précurseurs y occupe une place prépondérante et conditionne l’établissement d’une méthode de détection et d’acquisition des données. Dans ce même chapitre sont successivement traités la mise au point de la méthode chromatographique pour l’analyse des stabilisants par LC-MS/MS, le couplage LC-MS/MS, la collecte et préparation des échantillons, dont l’extraction sur phase solide (SPE). Disposant des procédures de traitement des échantillons et d’une méthode LC-MS/MS, il nous a été possible de mener l’étude de faisabilité de l’analyse des stabilisants dans les échantillons prélevés sur les mains d’un tireur. Cette étude fait l’objet d’une proposition de publication jointe en annexe. Pour être exploitable en criminalistique, ce travail est complété par une étude sur les fréquences d’observation des stabilisants pour poudres propulsives sur les mains des non-tireurs.<p>L’ensemble des résultats nous permet de dresser un bilan et proposer des perspectives décrites dans le chapitre 3. A cet égard, nous proposons de poursuivre les essais relatifs aux tests de persistance des résidus de stabilisant sur les mains des tireurs et d’entamer une étude sur la caractérisation des résidus de tir de la nitrocellulose. Du point de vue de l’exploitation des acquis de ce travail, nous suggérons que les méthodes et procédures développées soient mises à l’épreuve dans les affaires nécessitant l’analyse des prélèvements effectués sur les vêtements d’un suspect ou d’une victime. Cette mise à l’épreuve permettra de comparer l’efficacité de la méthode LC-MS/MS à celle de la technique SEM/EDX habituellement utilisée. <p>Le chapitre 4 est consacré aux matériels et méthodes détaillant notamment les procédures de collectes et de traitement des échantillons, les paramètres de fonctionnement du spectromètre de masse et les méthodes analytiques.<p><p><br><p><br><p><p>This thesis deals with a research project entitled "Development of an integral system of detection and identification of gunshot residues”, carried out at the Belgian National Institute of Criminalistics and Criminology (NICC). This project aims at providing the Laboratory of Chemical Ballistics, a powerful tool to detect and identify organic gunshot residues. For instance, the analyses of gunshot residues is presently performed mainly for characterizing metallic particles originating from the primer, using scanning electron microscopy coupled to energy dispersive X-ray microanalysis (SEM-EDX). However this technique has its limits and the goal of the thesis was the development of a method for the analysis of the stabilizers (and their derivatives) present in propellant powders with the use of tandem mass spectrometry coupled to high performance liquid chromatography (LC-MS/MS).<p>The introduction highlights the relations between Criminology and Criminalistics; it gives an outline of the classification of weapons, and describes how handguns, ammunitions, gunshot residues and Criminalistics can be linked when investigating criminal cases. The motivation of the analysis of organic gunshot residues and in particular the propellant powder stabilizers is also explained.<p>Chapter 1 deals in detail with the working principle of a quadrupole mass spectrometer, whether it is with a single quadrupole or composed of a tandem mass spectrometer. Important aspects connected with the ion production, the data acquisition and the ion detection are also considered.<p>Chapter 2 presents the results and discussions. It begins with the optimization of the operating conditions of the spectrometer, and focuses more specifically on the determination of “precursor ions" and "daughter ions”. The study of the precursor ion is more important because it is required for the choice of parameters involved in the data acquisition mode. The development of a liquid chromatography (LC) method and the procedures for collecting and preparing the samples are explained. Moreover, Chapter 2 summarizes the results of a feasibility study of the analyses of stabilizers in samples collected from the hands of a shooter. This study was published in a peer reviewed journal [1]. A complementary study on the frequencies of observation of stabilizers on the hands of non-shooter persons is reported at the end the Chapter.<p>The results allow also proposing perspectives which are described in Chapter 3. In this respect, the characterization of nitrocellulose residues and the study of the persistence of stabilizer residues on the hands of shooters should be undertaken. From the practical point of view, the developed methods and procedures should be tested in real cases which involve the analyses of the samples taken from the clothing of suspects and/or victims. These tests should allow an assessment of the LC-MS/MS method compared to the efficiency of the SEM/EDX technique currently used.<p>Chapter 4 is dedicated to the materials and methods; the sample collection and treatment procedures, as well as the working parameters of the mass spectrometer and the analytical methods are explained in detail. <p>[1]. Désiré Laza, Ph.D. Bart Nys, Ph.D. Jan De Kinder, Ph.D. Andrée Kirsch - De Mesmaeker, Ph.D. and Cécile Moucheron, Ph.D. Development of a Quantitative LC-MS/MS Method for the Analysis of Common Propellant Powder Stabilizers in Gunshot Residue. J. Forensic Sci, July 2007, Vol. 52, N° 4, 842-850.<p> / Doctorat en Sciences / info:eu-repo/semantics/nonPublished

Page generated in 0.0437 seconds