• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 2
  • 1
  • Tagged with
  • 34
  • 34
  • 17
  • 12
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Águas de processo da REPLAN = qualidade e aplicação de processos oxidativos avançados / Process water from a Petroleum Refinery (REPLAN) : quality and application of advanced oxidation process

Gasparini, Mirthys Cozzett 18 August 2018 (has links)
Orientadores: José Roberto Guimarães, Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-18T03:12:06Z (GMT). No. of bitstreams: 1 Gasparini_MirthysCozzett_M.pdf: 1574617 bytes, checksum: 879f212f74e005fca5974d6f943a790e (MD5) Previous issue date: 2011 / Resumo: No presente trabalho foi realizada a caracterização de várias correntes de águas de processo da REPLAN (Refinaria de Paulínia), bem como a avaliação dos processos de fotólise (UV), peroxidação (H2O2), peroxidação assistida por radiação ultravioleta (H2O2/UV), reagente de Fenton (H2O2/Fe2+) e foto-Fenton (H2O2/Fe2+/UV) no tratamento de um dos efluentes, principalmente na degradação dos compostos orgânicos. Analisando-se os dados de caracterização dos diferentes efluentes foi possível sugerir alternativas de reuso no processo de refino, como também selecionar a corrente de água ácida retificada para aplicação dos processos físico-químicos de tratamento. A eficiência dos ensaios de tratabilidade foi baseada na redução da concentração do carbono orgânico dissolvido (COD). Dentre os processos estudados, os processos oxidativos avançados (POA) H2O2/UV e foto-Fenton apresentaram 95 % de eficiência após 150 minutos de ensaio. As condições ótimas foram obtidas na relação mássica COD: H2O2 de 1:7 para o processo peroxidação assistida por radiação UV, e de 1:5 e concentração de Fe2+ de 31 mg/L para o processo foto-Fenton. O efluente tratado pelo processo H2O2/UV poderia ser reutilizado como água de reposição no sistema de resfriamento, já que esta é responsável por 49 % do total de água utilizada na refinaria / Abstract: In the present study was performed the characterization of various process water from REPLAN (Paulínia Refinery) as well as an assessment of 5 processes to treat one of the effluents: photolysis (UV), peroxidation (H2O2), peroxidation assisted by ultraviolet radiation (H2O2/UV), Fenton reagent (H2O2/Fe2+) and photo-Fenton (H2O2/Fe2+/UV), in order to degrade the organic compounds. Effluents characterization results provided reuse possibilities in the process refining and also selected the stripped sour water stream for application of physical-chemical treatments. The processes efficiency was evaluated by the dissolved organic carbon (DOC) reduction. Among the processes studied, the advanced oxidation processes (AOPs) H2O2/UV and photo-Fenton reached 95 % efficiency after 150 minutes of reaction. The optimum conditions were obtained in a mass ratio COD: H2O2 of 1:7 for peroxidation assisted by UV radiation, and of 1:5 with 31 mg/L of Fe2+ for photo-Fenton. The effluent treated by AOP H2O2/UV could be reused as make-up water in cooling systems, since it is responsible for 49 % of the total water used in the refinery / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
22

Avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliester / Toxicity identification evaluation of polyester resin manufacturing wastewater

Caffaro Filho, Roberto Augusto 06 May 2008 (has links)
Orientador: Lucia Regina Durrant / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-10T19:47:18Z (GMT). No. of bitstreams: 1 CaffaroFilho_RobertoAugusto_D.pdf: 3860538 bytes, checksum: 5e0a12a4a24fb8f37e470a346d8bc95a (MD5) Previous issue date: 2008 / Resumo: Os processos industriais são geradores de uma ampla variedade de contaminantes que estão presentes nas águas residuarias. A seleção de processos de tratamento baseia-se nas características do efluente a ser tratado. Neste trabalho investigou-se um efluente tóxico da fabricação de resinas de poliéster. Existem poucas informações na literatura sobre este tipo de água residuaria. Procedeu-se a caracterização do efluente, efetuando-se a avaliação e identificação de constituintes tóxicos presentes no mesmo por meio de uma abordagem orientada por toxicidade. Foi utilizado bioensaio respirometrico em lodo ativado para avaliar a toxicidade do efluente bruto. Então, foram efetuados tratamentos físicos e químicos para fracionamento do efluente, e apos cada um deles, realizou-se o mesmo bioensaio. Dessa maneira, avaliou-se qual técnica de fracionamento foi a mais efetiva na redução da toxicidade. A maior redução de toxicidade foi observada apos o fracionamento do efluente por arraste com ar em pH 11 (62,5 %). Este resultado demonstrou que uma fração significativa da toxicidade do efluente para lodos ativados era causada por compostos orgânicos volatilizados em pH 11. Isso indica que o tratamento do efluente por arraste com ar em pH básico pode ter impacto positivo em um tratamento biológico aeróbio subseqüente. Uma vez determinado o tipo de compostos no efluente que provocam efeitos tóxicos (Compostos Organicos Volateis - COVs), procedeu-se a esforços analíticos visando a identificação dos mesmos. Analises por headspace do efluente por cromatografia gasosa e espectrometria de massa identificaram a presença de aldeidos insaturados (congeneres de acroleina). Tais compostos tinham relacao direta com o efeito tóxico observado. Foram também realizados bioensaios utilizando microrganismos anaerobios. Para tanto, mediu-se o volume de gas produzido por uma biomassa anaerobia em contato com o efluente bruto e com o efluente fracionado por arraste com ar em pH 11. Não se observou redução na toxicidade do efluente mesmo com este fracionamento. Comparando-se esses resultados aos obtidos com lodo ativados, foi verificado que os compostos removidos por arraste com ar em pH 11 não apresentaram o mesmo grau de toxicidade para esta biomassa anaerobia. Tais resultados indicam que a utilização de processo de tratamento biológico anaerobio seria uma opção adequada para a condução de futuros estudos de tratabilidade deste efluente. Os resultados obtidos neste trabalho de avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliéster ratificam a abordagem utilizada como uma valorosa ferramenta na caracterização de efluentes industriais tóxicos, principalmente nos casos onde não se encontram disponíveis informações especificas relacionadas ao efluente estudado / Abstract: Industrial processes generate a vast range of contaminants that are present in wastewaters. Treatment process selection is based on wastewater characteristics. In this work a toxic polyester resin manufacturing wastewater was investigated. Specific literature on this kind of wastewater is rare. The characterization of this wastewater was conducted, evaluating and identifying toxicity by applying a toxicity-oriented approach. An activated sludge respirometric bioassay was used to assess effluent toxicity. Then, physical and chemical treatments were performed for effluent fractionation. After each fractionation, the same bioassay was conducted. In this way, it was assessed which fractionation technique was the most effective in reducing effluent toxicity. The greater toxicity reduction was observed after effluent fractionation with air stripping in pH 11 (62.5 %). This result showed that a significant fraction of wastewater toxicity for activated sludge was caused by organic compounds volatilized in pH 11. This indicates that effluent treatment by air stripping in basic pH could have a positive impact in a conjugated aerobic biological treatment. Once the type of compounds causing wastewater toxicity has been determined (Volatile Organic Compounds ¿ VOCs), analytical efforts aiming the identification of these compounds were made. Wastewater headspace gas chromatographic analyses coupled with mass spectrometry identificated the presence of a,ß-unsaturated aldehydes (acrolein congeners). These compounds were directly related to the observed toxic effect. Bioassays using anaerobic microorganisms were also conducted. To that purpose, the volume of gas produced by an anaerobic biomass in contact with the baseline effluent and with the fractionated effluent by air stripping in pH 11 was measured. No toxicity reduction was observed with this fractionation. By comparing this result with the one obtained with the respirometric bioassay, it was found that the compounds removed by air stripping in pH 11 did not inhibit this kind of biomass in the same degree which they inhibited activated sludge. This indicates that the use of an anaerobic treatment process would be an adequate option for conducting future treatability studies in this wastewater. The results obtained in this research of toxicity identification evaluation of a polyester resin manufacturing effluent confirm that the toxicity-oriented approach is a valuable tool for the characterization of toxic industrial wastewaters, especially in cases when specific information related to the studied wastewater is lacking / Doutorado / Doutor em Ciência de Alimentos
23

Tratamento de efluente líquido da indústria de vidros com semente de moringa oleífera / Wastewater treatment of the glass industry with Moringa oleifera

Zampero, Rosangela 09 December 2011 (has links)
Made available in DSpace on 2016-05-02T13:54:10Z (GMT). No. of bitstreams: 1 RosangelaZampero-dissertacaocompleta.pdf: 820803 bytes, checksum: ec31de7b8b2d172d25dda29c7917c9ef (MD5) Previous issue date: 2011-12-09 / The use of biopolymers extracted from plants in the clotting process has several advantages compared with chemical salts. Among the advantages: low cost and variation in the nature of the alkalinity of the water in the process, because the sludge generated after treatment has lower volume compared with the sludge generated with the use of chemical constituents. The specific study of wastewater generated in the industry of glass quenching calls attention to the high rate of waste sludge. The effluent is a major concern regarding the disposal or reuse. In this case, the hardening process studied uses 110,000 liters of water per month, which generates 40 tons / month of solid waste and consequently large volumes of wastewater. During the study the objective was to check the behavior of Moringa oleifera seeds as natural coagulant in the effluent liquid from the glass industry and water reuse in the process. / O uso de biopolímeros extraídos de vegetais no processo de coagulação tem várias vantagens em comparação com os sais químicos. Dentre as vantagens, destaca-se o baixo custo e o fato que não existe variação na natureza da alcalinidade da água no processo, pois o lodo gerado após tratamento apresenta menor volume quando comparado com o lodo gerado com uso de constituintes químicos. O estudo dos efluentes líquidos gerados na indústria de têmpera de vidros chamou a atenção pelo alto índice de lodos residuais. Este efluente é a grande preocupação quanto ao seu descarte ou reuso. Neste caso, o processo de têmpera estudado utiliza 110 mil litros de água por mês, que gera 40 ton./mês de efluentes sólidos e consequentemente grande volume de efluente líquido. No decorrer do estudo objetivou-se verificar o comportamento das sementes de Moringa oleifera como coagulante natural no efluente líquido da indústria de vidros e reuso da água no processo.
24

Tratamiento de efluentes de la industria alimentaria por coagulación-floculación utilizando almidón de Solanum tuberosum L. ‘papa’ como alternativa al manejo convencional

Molano Linares, Jazmin Desider January 2016 (has links)
Se evaluó el tratamiento de efluentes de la industria alimentaria por coagulación-floculación utilizando almidón de Solanum tuberosum L. „papa‟ como alternativa al manejo convencional. Los ensayos se realizaron a escala de laboratorio realizando la prueba de jarras con dos coagulantes: sulfato de aluminio y policloruro de aluminio, y dos floculantes: poliacrilamida aniónica y almidón gelatinizado, con variaciones en relación a dosis, concentración y velocidad. Para determinar los parámetros ideales se utilizaron las siguientes variables respuesta: índice de Willcomb, absorbancia, turbidez y demanda química de oxígeno. El mejor tratamiento fue con el coagulante policloruro de aluminio y el floculante poliacrilamida aniónica alcanzándose un porcentaje de reducción de DQO de 83,05%. Aun así, los resultados al utilizar almidón sugieren que se puede reemplazar la poliacrilamida aniónica por el almidón de S. tuberosum al aplicar un tratamiento primario a un efluente industrial no doméstico de una empresa alimentaria ubicada en el distrito de Ate en la ciudad de Lima, Perú para cumplir los Valores máximos admisibles del Decreto Supremo N°021-009-Vivienda, en el aspecto de la carga orgánica presente.Treatment of industrial wastewater was evaluated through coagulation-floculation using starch of Solanum tuberosum L. „potato‟ as an alternative to the conventional management. Assays were performed in a laboratory scale by performing Jar Test with two coagulants: aluminum sulfate and aluminum polychloride, and two flocculants: anionic polyacrylamide and gelatinized starch, making variations in dose, concentration and speed. To determine the ideal parameters, the following response variables were used: Willcomb index, absorbance, turbidity and chemical oxygen demand. The best treatment was when using aluminum polychloride as coagulant and anionic polyacrylamide as flocculant, reaching a reduction percentage of 83,05% in chemical oxygen demand. Even then, the results suggest that can the anionic polyacrylamide can be replaced by starch of S. tuberosum when applying a primary treatment to industrial wastewater from a food company located in the district of Ate in Lima, Perú to meet the admisible values set in the Supreme Decree No. 021-009-VIVIENDA, in the aspect of organic matter present in it.
25

Tratamento de efluentes da produção de tintas industriais, automotivas e de  repintura por irradiação com feixe de elétrons / Treatment of effluent from industrial automotive and refinish paints by electron beam irradiation

Nascimento, Fernando Codelo 09 September 2013 (has links)
Tinta pode ser conceituada como uma película ou camada de polímero utilizada para proteger, sinalizar e iluminar ou mesmo para embelezar o substrato sobre o qual ela é aplicada. Basicamente, esta mistura polimérica é formada por elementos, tais como: resinas, pigmentos, cargas, solventes e aditivos. Os resíduos e o efluente líquido gerados na produção de tintas devem ser tratados de modo que não causem contaminação de rios e das nascentes de água. A reutilização do efluente tratado é uma das possibilidades que deve ser considerada a fim de minimizar os impactos ambientais e reduzir o uso de recursos naturais. Processos de oxidação química são promissores para a degradação de compostos orgânicos tóxicos. O caminho mais eficiente para a oxidação é o ataque pelo radical hidroxila (OH), por meio do processo de oxidação avançada, POA. Um dos exemplos de POA é o que faz uso de aceleradores de feixe de elétrons, adotado por vários países para a remoção de compostos orgânicos. O objetivo deste estudo é aplicar o POA por radiação ionizante para o tratamento do efluente da fabricação de tintas para repintura automotiva, industrial e automotivo. A metodologia utilizada foi um estudo de caso, desenvolvido por meio do processamento com feixe de elétrons aplicados a esses efluentes de indústria de tintas. O estudo foi realizado em três fases. Na primeira, aplicou-se 10 kGy, 30 kGy e 50 kGy de dose absorvida; na segunda, 50 kGy, 80 kGy e 100 kGy, e, na última fase, foi aplicada nas amostras uma dose de 50 kGy e dopadas com 0,005%, 0,05% e 0,5% de peróxido de hidrogénio em volume. Os principais resultados demonstraram uma redução média de cerca de 10% da Demanda Química de Oxigênio, DQO e cerca de 25% da Demanda Bioquímica de Oxigênio, DBO. Os padrões de efluentes finais definidos pelos requisitos legais, em especial pelo Decreto Estadual 8468/1976. para o descarte do corpo no rio ou reutilização em aplicações industriais, foram atendidos. / Paint can be conceptualized as a film or a layer of polymer, to protect, to signal and to illuminate or even to embellish the substrate on which it is applied. Basically, this polymeric compound is formed by elements such as: resin, pigments, fillers, solvents, and additives. Waste and wastewater generated in the production of paint, have to be treated so they do not cause the contamination of rivers and springs water. The reuse of the treated effluent is one of the possibilities that should be considered in order to minimize the environmental impacts and to reduce the use of natural resources. Chemical oxidation processes are promising for degradation of toxic organic compounds. The most efficient path for the oxidation is the attack by hydroxyl radical (OH), and the Advanced Oxidation Process, AOP, using electron beam accelerators have been adopted by several countries for the removal of organic compounds. The aim of this study is to apply the AOP by ionizing radiation to treat the effluent from the manufacture of automotive, automotive refinish and industrial paints. The methodology used was a case study, developed through the electron beam processing of these effluents. The study was developed in three phases: in the first one it was applied 10 kGy, 30 kGy and 50 kGy of absorbed dose, in the second one, 50 kGy, 80 kGy and 100 kGy, and in the last one it was applied 50 kGy in samples and doped with 0.005%, 0.05% and 0.5% of hydrogen peroxide. The main results have shown an average reduction of about 10% of Chemical Oxygen Demand, COD and about 25% of Biochemical Oxygen Demand, BOD. The final effluent standards set by legal requirements for disposal of the body in the river or reuse in industrial application.
26

Avaliação dos processos de nitrificação e desnitrificação das águas residuárias de uma indústria química / Evaluation of nitrification-denitrification processes of wastewater of chemical industry

Sassim, Márcio Nemer Machado 24 May 2001 (has links)
Um sistema de tratamento constituído de um reator anaeróbio de mistura completa e um reator anaeróbio compartimentado (ABR) foi operado durante 140 dias para estudar os efeitos do pré-tratamento das águas residuárias de uma indústria química, por carvão ativado em pó (CAP), e suas implicações nos processos de nitrificação e desnitrificação. Utilizou-se, no pré-tratamento do resíduo, duas concentrações de carvão ativado em pó. Para aplicação de 10 mg/l de CAP a remoção de DQO foi de 60% e a de NTK foi de 50%. Nesta fase, os processos de remoção de nitrogênio foram plenamente viabilizados. Para 5 mg/l de CAP a remoção de DQO foi de 44% e a remoção de NTK 46%, neste período se observou inibição por metais pesados e acúmulo de nitrito no sistema. / A treatment system composed of both an aerobic complete-mix reactor and a anaerobic baftled reactor (ABR) was operated for 140 days to study the effects of the treatment of wastewater chemical industry by powdered activate carbon (PAC) and its implications in nitrification - denitrification processes. In the residue preliminary treatment, two concentrations of PAC were used. For the application of 10 mg/l of CAP the removal of COD was 60% and the removal of TKN was 50%. In this phase, the processes of nitrogen removal were possible to be completely carried out. For 5 mg/l of CAP, the removal of COD was 44% and the removal of TKN 46%. In this period, the inhibition by heavy metaIs and nitrite accumulation in the system was observed.
27

Redução de carga orgânica recalcitrante de efluente de indústria gráfica por reação de fenton / Reduction of recalcitrant organic matter in wastewater of graphic industry by fenton reaction

Frederico José de Vaz e Paiva 18 December 2009 (has links)
A Casa da Moeda do Brasil (CMB) é uma empresa nacional, com mais de 300 anos de experiência na produção de valores e impressos de segurança. A produção de cédulas, realizada pelo Departamento de Cédulas (DECED), consiste de três etapas de impressão, off-set, calografia e tipografia, seguida de acabamento e embalagem semi-automatizado. A impressão calcográfica consome solução de limpeza, composta de soda cáustica e óleo sulfonado, para limpeza do cilindro de impressão, gerando um efluente líquido saturado de tinta. Este efluente apresenta baixa biodegradabilidade, apresentando uma relação DBO / DQO de aproximadamente 1:4. Em termos de tratabilidade, as estações de tratamento de efluentes (ETE) apresentam uma configuração convencional, por via biológica, demonstram pouca eficiência na degradação da matéria orgânica deste efluente. Com compostos recalcitrantes, torna-se necessária a inclusão de uma etapa terciária que permita sua degradação por via química, permitindo o descarte do efluente com características menos danosas ao ambiente. Neste trabalho, aplicou-se a reação de Fenton no efluente do DECED por sua capacidade de converter a matéria orgânica em gás carbônico e água ou, caso seja utilizado em pré-tratamentos, torna-os biodegradáveis. Foram estudadas diferentes condições para medir a influência de diferentes parâmetros na eficiência da reação. A reação de Fenton consiste na geração de radicais hidroxil (HO), por diferentes rotas, em quantidades suficientes para a degradação de matéria orgânica. Esses radicais são gerados a partir de peróxido de hidrogênio (H2O2) em reações com diferentes precursores como ozônio (O3), luz UV (ultravioleta), ultra-som e sais de ferro. No presente trabalho restringiu-se às reações com sais de ferro. Dentre os resultados obtidos, verificou-se o tempo mínimo para reação em 10 minutos. A relação entre íons ferro e peróxido de hidrogênio é menor do que a literatura normalmente sugere, 1:2, contra 1:3. Como a solução de sulfato ferroso é muito instável, passando os íons ferrosos a férricos, utilizou-se a adição direta do sal. Em escala industrial, a solução de sulfato ferroso deve ser preparada em poucas quantidades para que tenha baixo tempo de estocagem, a fim de não ser degradada. A temperatura, na faixa estudada (de 20C à 45C), é um parâmetro que tem pouca influência, pois a redução da eficiência da reação foi pequena (de 99,0% para 94,9%). O ferro utilizado na reação não se demonstrou uma nova fonte de transtornos para o ambiente. Nas condições utilizadas, a concentração de ferro residual esteve próxima ao limite permitido pela legislação no efluente tratado, necessitando apenas de alguns ajustes para a correção do problema / The Brazilians Mint (CMB) is a national enterprise, with more than 300 years of experience in the production of values and security printings. The production of banknotes, carried out by the Departamento de Cédulas (DECED), consists of three printing stages: off-set, intaglio and typography, followed by finishing and semiautomated packing. The intaglio impression consumes cleaning solution, composed by caustic soda and sulfonated castor oil, for cleaning of the printing cylinder, producing an ink saturated wastewater. This wastewater presents low biodegradability, showing a BOD / COD ratio of approximately 1:4. In terms of treatability, the effluent treatment stations (ETS) has presented a conventional configuration, for biological means, has showed a low efficiency in the organic matter degradation of this effluent. With recalcitrant compounds, its necessary the inclusion of a tertiary stage that allows its degradation by chemical means, allowing discarding it with less harmful characteristics to the environment. In this work, the Fenton reaction was applied in the DECED industrial wastewater due to its capacity of converting the organic matter into carbonic gas and water or, if it is used in pay-treatment, turn them into biodegradable (AGUIAR et al., 2007). Different conditions have been studied to measure the influence of different parameters in the reaction efficiency. The Fenton reaction consists in the hidroxyl radicals (HO) generation, by different means, in sufficient quantities for the organic matter degradation. These radicals are produced from of peroxide hydrogen (H2O2) in reactions with different precursors like ozone (O3), UV light, ultrasound and iron salts (GOGATE and PANDIT, 2004). Here we restricted ourselves to the reactions with iron salts. Among the obtained results, it has been verified the minimun time for reaction in 10 minutes. The ratio between iron ions and hydrogen peroxide is lower than suggests the literature (1:2), against (1:3). Since the ferrous sulphate solution is very unstable, because the ferrous ions turn into ferric ions, straight addition of the salt was used. In industrial scale, the ferrous sulfate solution must be prepared in little quantities so that it has low time of stock, in order to not be degraded. The temperature, in the studied range, is a parameter that has little influence, since the efficiency reduction of the reaction was low. The iron used in the reaction did not demonstrate itself a new source of damages for the environment. In the used conditions, the iron concentration was near to maximum limit allowed by the legislation in the effluent treatment, just needing some adjustments to sort out the problem
28

Tratamento de efluentes da produção de tintas industriais, automotivas e de  repintura por irradiação com feixe de elétrons / Treatment of effluent from industrial automotive and refinish paints by electron beam irradiation

Fernando Codelo Nascimento 09 September 2013 (has links)
Tinta pode ser conceituada como uma película ou camada de polímero utilizada para proteger, sinalizar e iluminar ou mesmo para embelezar o substrato sobre o qual ela é aplicada. Basicamente, esta mistura polimérica é formada por elementos, tais como: resinas, pigmentos, cargas, solventes e aditivos. Os resíduos e o efluente líquido gerados na produção de tintas devem ser tratados de modo que não causem contaminação de rios e das nascentes de água. A reutilização do efluente tratado é uma das possibilidades que deve ser considerada a fim de minimizar os impactos ambientais e reduzir o uso de recursos naturais. Processos de oxidação química são promissores para a degradação de compostos orgânicos tóxicos. O caminho mais eficiente para a oxidação é o ataque pelo radical hidroxila (OH), por meio do processo de oxidação avançada, POA. Um dos exemplos de POA é o que faz uso de aceleradores de feixe de elétrons, adotado por vários países para a remoção de compostos orgânicos. O objetivo deste estudo é aplicar o POA por radiação ionizante para o tratamento do efluente da fabricação de tintas para repintura automotiva, industrial e automotivo. A metodologia utilizada foi um estudo de caso, desenvolvido por meio do processamento com feixe de elétrons aplicados a esses efluentes de indústria de tintas. O estudo foi realizado em três fases. Na primeira, aplicou-se 10 kGy, 30 kGy e 50 kGy de dose absorvida; na segunda, 50 kGy, 80 kGy e 100 kGy, e, na última fase, foi aplicada nas amostras uma dose de 50 kGy e dopadas com 0,005%, 0,05% e 0,5% de peróxido de hidrogénio em volume. Os principais resultados demonstraram uma redução média de cerca de 10% da Demanda Química de Oxigênio, DQO e cerca de 25% da Demanda Bioquímica de Oxigênio, DBO. Os padrões de efluentes finais definidos pelos requisitos legais, em especial pelo Decreto Estadual 8468/1976. para o descarte do corpo no rio ou reutilização em aplicações industriais, foram atendidos. / Paint can be conceptualized as a film or a layer of polymer, to protect, to signal and to illuminate or even to embellish the substrate on which it is applied. Basically, this polymeric compound is formed by elements such as: resin, pigments, fillers, solvents, and additives. Waste and wastewater generated in the production of paint, have to be treated so they do not cause the contamination of rivers and springs water. The reuse of the treated effluent is one of the possibilities that should be considered in order to minimize the environmental impacts and to reduce the use of natural resources. Chemical oxidation processes are promising for degradation of toxic organic compounds. The most efficient path for the oxidation is the attack by hydroxyl radical (OH), and the Advanced Oxidation Process, AOP, using electron beam accelerators have been adopted by several countries for the removal of organic compounds. The aim of this study is to apply the AOP by ionizing radiation to treat the effluent from the manufacture of automotive, automotive refinish and industrial paints. The methodology used was a case study, developed through the electron beam processing of these effluents. The study was developed in three phases: in the first one it was applied 10 kGy, 30 kGy and 50 kGy of absorbed dose, in the second one, 50 kGy, 80 kGy and 100 kGy, and in the last one it was applied 50 kGy in samples and doped with 0.005%, 0.05% and 0.5% of hydrogen peroxide. The main results have shown an average reduction of about 10% of Chemical Oxygen Demand, COD and about 25% of Biochemical Oxygen Demand, BOD. The final effluent standards set by legal requirements for disposal of the body in the river or reuse in industrial application.
29

Avaliação dos fatores abióticos e bióticos de uma área petroquímica da região de Paulínia, SP, e fotodocumentação dos fungos transientes isolados

Cruz, Aline da Silva [UNESP] 12 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-12Bitstream added on 2014-06-13T19:35:29Z : No. of bitstreams: 1 cruz_as_me_rcla.pdf: 2096941 bytes, checksum: e034fe58bade607f70d6be667b1b3079 (MD5) / A ocupação do solo e a demanda de água doce tem sido crescente, de maneira que pesquisas voltadas à avaliação da qualidade das águas em áreas estratégicas são consideradas fundamentais. Neste contexto, a área de estudos foi escolhida pela disponibilidade de água, distribuição demográfica e pela sua importância industrial. Com o propósito de melhor compreender o impacto causado pelo efluente do pólo petroquímico de Paulínia, SP, na qualidade das águas do rio Atibaia, os parâmetros potencial hidrogeniônico (pH), temperatura da água, sólidos totais, turbidez, oxigênio dissolvido (OD), demanda bioquímica de oxigênio (DBO), nitrogênio total (NT), íons fósforo (íons P), pluviosidade, estações seca e chuvosa, condutividade elétrica da água e concentração de cloretos foram analisados. Verificou-se, ainda, a influência dos parâmetros mencionados sobre a micobiota transiente de amostras coletadas no período entre agosto de 2007 a março de 2009. O método de plaqueamento para contagem dos fungos e as análises físicas e químicas seguiram Clesceri et al. (1998). Correlação de Pearson, análise de variância multivariada, correlação canônica para dados multivariados e análise dos componentes principais foram as análises estatísticas realizadas. Estas revelaram diferentes influências dos parâmetros independentes sobre as contagens fúngicas. A micobiota transiente detectada no período estudado foi sensível aos parâmetros cloretos, sólidos totais, condutividade elétrica da água e OD, pois estes fatores abióticos influenciaram negativamente nas contagens. Entretanto, o número de colônias de fungos foi estimulada positivamente pela pluviosidade (estação chuvosa), DBO, turbidez e NT. Das análises estatísticas, apenas a correlação de Pearson pareceu não ser eficiente para estudos ambientais sujeitos a variações diversas / The use of the soil and fresh-water has increased, so that investigations on the water quality in strategic areas are considered of fundamental importance. In this context, the study area was chosen for its water availability, demographic distribution and industrial relevance. With an eye on the water quality of the influence of an industrial effluent discharged in the Atibaia river, in the surroundings of a petrochemical refinery in Paulínia, SP, the following parameters were analyzed: pH, water temperature; total dissolved solids; turbidity; dissolved oxygen (DO); biochemical oxygen demand (BOD), total nitrogen (TN), phosphorous; rain; dry and rain seasons; water conductivity and chlorides. Also, the influence of these parameters on transient mycota between August 2007 and March 2009 was investigated. The method for counting the forming colony units of fungi was according to Clesceri et al. (1998). Pearson correlation coefficient, multivariate analysis of variance, canonical correlation to multivariate data and principal component analysis were the statistical methods employed. The results revealed differences in the influence of the independent parameters on the counting of fungal colony forming units (CFU). The fungi present in the samples were negatively affected by chloride concentration, total dissolved solids, water conductivity and DO. However, the CFU was increased by the rain, BOD, turbidity and TN. Among the statistical tests used, only Pearson correlation was not satisfactory for our studies
30

Redução de carga orgânica recalcitrante de efluente de indústria gráfica por reação de fenton / Reduction of recalcitrant organic matter in wastewater of graphic industry by fenton reaction

Frederico José de Vaz e Paiva 18 December 2009 (has links)
A Casa da Moeda do Brasil (CMB) é uma empresa nacional, com mais de 300 anos de experiência na produção de valores e impressos de segurança. A produção de cédulas, realizada pelo Departamento de Cédulas (DECED), consiste de três etapas de impressão, off-set, calografia e tipografia, seguida de acabamento e embalagem semi-automatizado. A impressão calcográfica consome solução de limpeza, composta de soda cáustica e óleo sulfonado, para limpeza do cilindro de impressão, gerando um efluente líquido saturado de tinta. Este efluente apresenta baixa biodegradabilidade, apresentando uma relação DBO / DQO de aproximadamente 1:4. Em termos de tratabilidade, as estações de tratamento de efluentes (ETE) apresentam uma configuração convencional, por via biológica, demonstram pouca eficiência na degradação da matéria orgânica deste efluente. Com compostos recalcitrantes, torna-se necessária a inclusão de uma etapa terciária que permita sua degradação por via química, permitindo o descarte do efluente com características menos danosas ao ambiente. Neste trabalho, aplicou-se a reação de Fenton no efluente do DECED por sua capacidade de converter a matéria orgânica em gás carbônico e água ou, caso seja utilizado em pré-tratamentos, torna-os biodegradáveis. Foram estudadas diferentes condições para medir a influência de diferentes parâmetros na eficiência da reação. A reação de Fenton consiste na geração de radicais hidroxil (HO), por diferentes rotas, em quantidades suficientes para a degradação de matéria orgânica. Esses radicais são gerados a partir de peróxido de hidrogênio (H2O2) em reações com diferentes precursores como ozônio (O3), luz UV (ultravioleta), ultra-som e sais de ferro. No presente trabalho restringiu-se às reações com sais de ferro. Dentre os resultados obtidos, verificou-se o tempo mínimo para reação em 10 minutos. A relação entre íons ferro e peróxido de hidrogênio é menor do que a literatura normalmente sugere, 1:2, contra 1:3. Como a solução de sulfato ferroso é muito instável, passando os íons ferrosos a férricos, utilizou-se a adição direta do sal. Em escala industrial, a solução de sulfato ferroso deve ser preparada em poucas quantidades para que tenha baixo tempo de estocagem, a fim de não ser degradada. A temperatura, na faixa estudada (de 20C à 45C), é um parâmetro que tem pouca influência, pois a redução da eficiência da reação foi pequena (de 99,0% para 94,9%). O ferro utilizado na reação não se demonstrou uma nova fonte de transtornos para o ambiente. Nas condições utilizadas, a concentração de ferro residual esteve próxima ao limite permitido pela legislação no efluente tratado, necessitando apenas de alguns ajustes para a correção do problema / The Brazilians Mint (CMB) is a national enterprise, with more than 300 years of experience in the production of values and security printings. The production of banknotes, carried out by the Departamento de Cédulas (DECED), consists of three printing stages: off-set, intaglio and typography, followed by finishing and semiautomated packing. The intaglio impression consumes cleaning solution, composed by caustic soda and sulfonated castor oil, for cleaning of the printing cylinder, producing an ink saturated wastewater. This wastewater presents low biodegradability, showing a BOD / COD ratio of approximately 1:4. In terms of treatability, the effluent treatment stations (ETS) has presented a conventional configuration, for biological means, has showed a low efficiency in the organic matter degradation of this effluent. With recalcitrant compounds, its necessary the inclusion of a tertiary stage that allows its degradation by chemical means, allowing discarding it with less harmful characteristics to the environment. In this work, the Fenton reaction was applied in the DECED industrial wastewater due to its capacity of converting the organic matter into carbonic gas and water or, if it is used in pay-treatment, turn them into biodegradable (AGUIAR et al., 2007). Different conditions have been studied to measure the influence of different parameters in the reaction efficiency. The Fenton reaction consists in the hidroxyl radicals (HO) generation, by different means, in sufficient quantities for the organic matter degradation. These radicals are produced from of peroxide hydrogen (H2O2) in reactions with different precursors like ozone (O3), UV light, ultrasound and iron salts (GOGATE and PANDIT, 2004). Here we restricted ourselves to the reactions with iron salts. Among the obtained results, it has been verified the minimun time for reaction in 10 minutes. The ratio between iron ions and hydrogen peroxide is lower than suggests the literature (1:2), against (1:3). Since the ferrous sulphate solution is very unstable, because the ferrous ions turn into ferric ions, straight addition of the salt was used. In industrial scale, the ferrous sulfate solution must be prepared in little quantities so that it has low time of stock, in order to not be degraded. The temperature, in the studied range, is a parameter that has little influence, since the efficiency reduction of the reaction was low. The iron used in the reaction did not demonstrate itself a new source of damages for the environment. In the used conditions, the iron concentration was near to maximum limit allowed by the legislation in the effluent treatment, just needing some adjustments to sort out the problem

Page generated in 0.0639 seconds