• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 3
  • 2
  • 1
  • Tagged with
  • 24
  • 24
  • 24
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modeling and analysis of a two loop controlled boost regulator in a satellite application

Sable, Daniel Mark January 1985 (has links)
M.S.
22

Current-mode control of a magnetic amplifier post regulator

Keller, Lisa A. 13 February 2009 (has links)
An analysis is presented on current-mode control of a magnetic amplifier post regulator. Small-signal models for a magnetic amplifier reset method are developed for post regulators operating in continuous conduction mode. A design procedure is given and experimental verification of the model is provided. / Master of Science
23

High power-supply rejection current-mode low-dropout linear regulator

Patel, Amit P. 08 April 2009 (has links)
Power management components can be found in a host of different applications ranging from portable hand held gadgets to modern avionics to advanced medical instrumentations, among many other applications. Low-dropout (LDO) linear regulators are particularly popular owing to their: ease of use, low cost, high accuracy, low noise, and high bandwidth. With all its glory, however, it tends to underperform switched-mode power supplies (SMPS) when with comes to power conversion efficiency, although the later generates a lot of ripple at its output. With the growing need to improve system efficiency (hence longer battery life) without degrading system performance, many high end (noise sensitive) applications such as data converters, RF transceivers, precision signal conditioning, among others, use high efficiency SMPS with LDO regulators as post-regulators for rejecting the ripple generated by SMPS. This attribute of LDO regulators is known as power supply rejection (PSR). With the trend towards increasing switching frequency for SMPS, to minimize PC board real estate, it is becoming ever more difficult for LDO regulators to suppress the associate high frequency ripple since at such high frequencies, different parasitic components of the LDO regulator start to deteriorate its PSR performance. There have been a handful of different techniques suggested in the literature that can be used to achieve good PSR performance at higher frequencies. However, each of these techniques suffers from a number of drawbacks ranging from reduced efficiency to increased cost to increased solution size, and with the growing demand for higher efficiency and smaller power supplies, these techniques have their clear limitations. The objective of this research project is to develop a novel current-mode LDO regulator that can achieve good high frequency PSR performance without suffering from the afore mentioned drawbacks. The proposed architecture was fabricated using a proprietary 1.5 um Bipolar process technology, and the measurement results show a PSR improvement of 20dB (at high frequencies) over conventional regulators. Moreover, the proposed LDO regulator requires a small 15nF output capacitor for stability, which is far smaller than some of the currently used techniques.
24

A comparative analysis of proportional-integral compensated shunt active power filters

Gray, Matthew Alan. January 2004 (has links)
Thesis (M.S.) -- Mississippi State University. Department of Electrical and Computer Engineering. / Title from title screen. Includes bibliographical references.

Page generated in 0.0815 seconds