• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise dos usos finais de energia elétrica na produção do frango de corte no Oeste do Paraná / Analysis of the end uses of electricity in broiler production in western Paraná

Rovaris, Solles Augusto 09 November 2015 (has links)
Made available in DSpace on 2017-07-10T15:14:34Z (GMT). No. of bitstreams: 1 DissertacaoSollesRovaris.pdf: 3539464 bytes, checksum: 89279d74c1996e8268639ae354b6fc47 (MD5) Previous issue date: 2015-11-09 / This study aimed to evaluate the consumption of electricity in two aviaries in dark house system, in 43 days period (corresponding period the accommodation of a batch of broilers). Both aviaries are located in the rural area of the municipality of São Miguel do Iguaçu, Paraná state's western region. The study was conducted to evaluate the energy consumption in final use electrical equipment installed in the aviary in lighting, air conditioner and power in the broiler production systems. In the two aviaries were measured the energy consumption, using gauges of electrical parameters Landis Gyr+ and Smart Meter IMS. The electricity consumption is calculated consumed by broiler, by broiler mass live and aviary unit area. The main results showed that during the whole broiler development period in the poultry 1 it was consumed 4510.94 kWh in total electricity energy. In the poultry 2, it was consumed 3756 kWh in total electricity energy utilized. These results support the conclusion that the aviary 2 became more economical in power consumption for the broilers production / O presente trabalho teve como objetivo avaliar o consumo de energia elétrica em dois aviários dark house, no período de 43 dias (período correspondente ao alojamento de um lote de frango de corte). Ambos os aviários estão localizados na área rural do município de São Miguel do Iguaçu, região Oeste do Estado do Paraná. O trabalho foi desenvolvido avaliando o consumo de energia elétrica no uso final de equipamentos elétricos utilizados no aviário em sistemas de iluminação, climatização e alimentação na produção de frangos de corte. Nos dois aviários foram medidos o consumo de energia elétrica em kWh, utilizando-se medidores de grandezas elétricas Landis Gyr+ e o Smart Meter IMS. Calculou-se o consumo de energia elétrica consumida por ave alojada, por massa de frango vivo e por unidade de área do aviário. Os principais resultados, permitiram concluir que durante todo o período de alojamento dos frangos de corte, no aviário 1 consumiu-se 4510,94 kWh no total de energia elétrica utilizada, No aviário 2, consumiu-se 3756 kWh no total de energia elétrica utilizada. Estes resultados, permitem concluir que o aviário 2 tornou-se mais econômico no consumo de energia elétrica para a produção de frangos de corte.
2

Elektros įrenginių saugos parametrų tyrimas / The investigation of security parameters of electrical equipment

Kneižys, Nerijus 20 June 2006 (has links)
In the present study, there was performed a research of safety parameters of electrical devices, there were performed various measurements and calculations, comparisons of received results, considered problems, associated with these parameters. There was considered condition of equipment before and after repairs.. Proposed suggestions regarding installation of unconventional devices as well as calculating during the process of design, there was described a research of dependence of resistances of grounders on deepening in earth, performing measurements. Also, upon selection of calculation methodology, there were performed calculations of grounded resistances. The results of calculations were compared with the measured ones. There was touched on a subject of solution of some problems of grounder installation - i.e. installation of unconventional grounder. There was provided the method of installation of such grounder, peculiarities of its equipment. There were analysed results of measurement of screws, they were compared with the results of conventional grounders. There was developed the methodology of calculations of grounders and there was provided data of calculations as well as comparison with the measured ones. There was described application of this method as well as its benefit and advantages. There were considered peculiarities of results of measurement of resistances of transitive contacts, positioned in chemically aggressive environment. There was analysed the... [to full text]
3

Σχεδίαση και ανάπτυξη μιας ολοκληρωμένης πλατφόρμας διαχείρισης δικτύων οικιακής/κτιριακής αυτοματοποίησης σε τοπικό ή απομακρυσμένο περιβάλλον

Τοπάλης, Ευάγγελος 22 June 2010 (has links)
- / -
4

[en] A BAYESIAN PROCEDUCE TO ESTIMATE THE INDIVIDUAL CONTRIBUTION OF INDIVIDUAL END USES IN RESIDENCIAL ELECTRICAL ENERGY CONSUMPTION / [pt] MODELO BAYESIANO PARA ESTIMAR AS CONTRIBUIÇÕES INDIVIDUAIS DE APARELHOS ELETRODOMÉSTICOS NO CONSUMO RESIDENCIAL DE ENERGIA ELÉTRICA

LUIS ALBERTO NAVARRO HUAMANI 19 July 2006 (has links)
[pt] Esta dissertação investiga a utilização do Modelo de Regressão Multivariada Seemingly Unrelated sob uma perspectiva Bayesiana, na estimação das curvas de carga dos principais eletrodomésticos. Será utilizada uma estrutura de Demanda Condicional (CDA), consideradas de especial interesse no setor comercial e residencial para o gerenciamento pelo lado da demanda (Demand Side Management) dos hábitos dos consumidores residenciais. O trabalho envolve três partes principais: uma apresentação das metodologias estatísticas clássicas usadas para estimar as curvas de cargas; um estudo sobre Modelos de Regressão Multivariada Seemingly Unrelated usando uma aproximação Bayesiana. E por último o desenvolvimento do modelo num estudo de caso. Na apresentação das metodologias clássicas fez-se um levantamento preliminar da estrutura CDA para casos univariados usando Regressão Múltipla, e multivariada usando Regressão Multivariada Seemingly Unrelated, onde o desempenho desta estrutura depende da estrutura de correlação entre os erros de consumo horário durante um dia específico; assim como as metodologias usadas para estimar as curvas de cargas. No estudo sobre Modelos de Regressão Multivariada Seemingly Unrelated a partir da abordagem Bayesiana considerou-se um fator importante no desempenho da metodologia de estimação, a saber: informação a priori. No desenvolvimento do modelo, foram estimadas as curvas de cargas dos principais eletrodomésticos numa abordagem Bayesiana mostrando o desempenho da metodologia na captura de ambos tipos de informação: estimativas de engenharia e estimativas CDA. Os resultados obtidos avaliados pelo método acima comprovaram superioridade na explicação de dados em relação aos modelos clássicos. / [en] The present dissertation investigates the use of multivariate regression models from a Bayesian point of view. These models were used to estimate the electric load behavior of household end uses. A conditional demand structure was used considering its application to the demand management of the residential and commercial consumers. This work is divided in three main parts: a description of the classical statistical methodologies used for the electric load prediction, a study of the multivariate regression models using a Bayesian approach and a further development of the model applied to a case study. A preliminary revision of the CDA structure was done for univariate cases using multiple regression. A similar revision was done for other cases using multivariate regression (Seemingly Unrelated). In those cases, the behavior of the structure depends on the correlation between a minimization of the daily demand errors and the methodologies used for the electric load prediction. The study on multivariate regression models (Seemingly Unrelated) was done from a Bayesian point of view. This kind of study is very important for the prediction methodology. When developing the model, the electric load curves of the main household appliances were predicted using a Bayesian approach. This fact showed the performance of the metodology on the capture of two types of information: Engineering prediction and CDA prediction. The results obtained using the above method, for describing the data, were better than the classical models.
5

Seguridad de equipos electromédicos: regulación sanitaria para la protección de la salud

Esquivel-Yániz, Sonia Hildelisa January 2011 (has links)
Submitted by Maria Creuza Silva (mariakreuza@yahoo.com.br) on 2013-05-13T14:15:28Z No. of bitstreams: 1 Tese Doutorado. Sonia Esquivel 13.05.13.pdf: 1914763 bytes, checksum: 0d2a2adda91a2994333e555aca4c7da2 (MD5) / Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-05-13T14:15:46Z (GMT) No. of bitstreams: 1 Tese Doutorado. Sonia Esquivel 13.05.13.pdf: 1914763 bytes, checksum: 0d2a2adda91a2994333e555aca4c7da2 (MD5) / Made available in DSpace on 2013-05-13T14:15:46Z (GMT). No. of bitstreams: 1 Tese Doutorado. Sonia Esquivel 13.05.13.pdf: 1914763 bytes, checksum: 0d2a2adda91a2994333e555aca4c7da2 (MD5) Previous issue date: 2011 / Trata-se de um estudo cujo objeto é a regulação sanitária de equipamentos eletromédicos, entendida como o controle sanitário desenvolvido pelo Estado, por meio das ações de vigilância sanitária, visando o controle de riscos e a segurança desses equipamentos. Tem como objetivo descrever e analisar o sistema regulatório brasileiro desses equipamentos a partir das instituições que o compõem, seus instrumentos e processos no exercício do controle sanitário, nos diferentes momentos regulatórios. Trata-se de um estudo de caso, tipo exploratório, tendo-se tomado como traçadores dois equipamentos eletromédicos: o ventilador pulmonar e o mamógrafo. Para a produção de dados foram utilizadas as técnicas de análise documental, entrevistas semi-estruturadas com informantes-chave e observação direta que permitiram descrever as bases normativas, os instrumentos e processos de controle sanitários aplicados ao longo do ciclo de vida dos equipamentos, pelos órgãos de vigilância sanitária e outras entidades que participam do controle. Também foram registradas considerações de fabricantes e usuários sobre as ações de controle sanitário e as limitações em sua execução. Os dados foram classificados e ordenados em uma matriz construída a partir do marco referencial do estudo e das categorias analíticas e operacionais definidas. Os resultados descrevem e analisam os componentes do processo regulatório brasileiro dos equipamentos eletromédicos, as instituições que compõem o sistema regulatório, seus instrumentos, processos e práticas, dificuldades e limites no exercício da regulação sanitária, nos diferentes momentos, bem como caracteriza a relação entre o sistema brasileiro e as normativas recomendadas por organizações internacionais. Foram evidenciadas dificuldades no exercício da regulação sanitária desses produtos, em face da dependência científica e tecnológica do Brasil, dos estágios iniciais dessa atividade no país e a pouca expertise dos profissionais de vigilância sanitária e de outras instituições reguladoras no relativo ao controle de riscos. / Salvador
6

Wireless transformer condition monitoring system

Zandberg, Hermanus Andries Jakobus January 2013 (has links)
The Department of Electrical Engineering in fulfilment of the requirements for the Magister Technologiae in Electrical Engineering at the Cape Peninsula University of Technology November 2013 / Pole mounted transformers (PMT) in rural areas present an opportunity for local utilities to do current monitoring on these systems. These transformers are exposed to abnormal amounts of stress due to the vast power demand in these areas. The aim of this study is to develop a more cost-effective condition monitoring system. Transformer current monitoring can be a dangerous practice if not done by suitably trained utility electricians. Hence this study is partly aimed at the elimination of hazardous working environments associated with manual electrical measurements. An investigation to determine a safe and cost-effective way to obtain the electrical measurements required from PMTs is undertaken. Although current measurements can be done with a current clamp-on meter, these measurements still take place at the phases of the transformer and are unsafe. The possibility of implementing wireless data gathering on current clamp-on meters is therefore investigated. This is made possible by a wireless sensor node (WSN) which gathers information and transmits it wirelessly to a WSN base station. This wireless solution is battery powered, necessitating battery replacements, therefore leading to the investigation of magnetic fields, magnetic materials and magnetic induction. A current clamp able to generate a high voltage (HV) output with minimal magnetic field strength is developed. The magnetic fields produced by the transformer’s phase cables are used to generate an alternating voltage. With the help of a microcontroller and an energy harvesting circuit, this voltage is converted and used to charge supercapacitors. The magnetic fields are also used to determine the current flow in the transformer phase cables when the device is not in energy harvesting mode. The device will then undergo comprehensive laboratory testing to determine its accuracy and durability, and is then used to do ‘real life’ current measurements, the results of which are compared against an off-the-shelf current monitoring device.
7

Gerenciamento de risco aplicado a procedimentos de ensaios de equipamentos eletromédicos. / Risk management applied to testing procedures medical electrical equipment.

Rosa, Diego Antonio de Oliveira 16 May 2012 (has links)
Os laboratórios de ensaios, para melhor avaliarem os equipamentos eletromédicos, precisarão implantar no seu sistema de gestão, o processo de Gerenciamento de Risco. Este novo tema está prescrito na edição da Norma ABNT NBR IEC 60601-1:2010 Requisitos Gerais para Segurança Básica e Desempenho Essencial que entrará em vigor a partir de 2012 no Brasil. A presente pesquisa tem como objetivo apresentar resumidamente as etapas do processo utilizado para implantar o Gerenciamento de Risco nos procedimentos de ensaios de equipamentos eletromédicos, visando atender aos novos requisitos da série de Normas ABNT NBR IEC 60601/80601 objetivando a melhoria contínua do Sistema de Gestão de laboratórios de ensaios acreditados pelo INMETRO. O método utilizado para o desenvolvimento deste trabalho consistiu no estudo detalhado das duas edições brasileiras da Norma Geral, de Normas Colaterais, a da Norma Particular de bomba de infusão e controladores, bem como a Norma ABNT NBR ISO 14971:2009. Após o estudo destas Normas, foram analisados alguns arquivos de Gerenciamento de Risco fornecidos por fabricantes de equipamentos eletromédicos e realizado o estudo de algumas ferramentas utilizadas para o desenvolvimento do Gerenciamento de Risco como, por exemplo, FMEA, FTA e HAZOP. Também foram realizados treinamentos com a equipe do laboratório de ensaio para sua capacitação. Com esta série de atividades, foi possível o desenvolvimento e implantação dos necessários procedimentos de ensaios na DEC-LEB/EPUSP e a validação dos mesmos. Para a validação desses procedimentos foi utilizada uma bomba de infusão, juntamente com todos os seus documentos acompanhantes. O resultado final obtido foi a capacitação da DEC-LEB/EPUSP para a realização de ensaios conforme as novas edições das Normas que incorporam Gerenciamento de Risco em suas prescrições, concluindo-se que os laboratórios de ensaios deverão incluir os devidos procedimentos com cuidado e capacitação de seus recursos humanos. / To better evaluate the medical electrical equipment the laboratories for testing will need to deploy in its management system, the process of Risk Management. This new theme is prescribed in the edition of ABNT NBR IEC 60601-1:2010, which will take effect from 2012 in Brazil. This research aims to show brief the process used to implement the Risk Management procedures for testing medical electrical equipment, to meet the new requirements of the series of ABNT NBR IEC 60601/80601 aiming at continuous improvement of the management systems of laboratories for testing accredited by INMETRO. The method used for the development of this research was the detailed study of two Brazilian editions of the General Standard, Collateral Standards, Particular Standard of infusion pumps and controllers, as well as the ABNT NBR ISO 14971:2009. After studying these Standards, some Risk Management files provided by manufacturers of medical electrical equipment were analyzed and performed the study of some tools used for the development of Risk Management, for example, FMEA, FTA and HAZOP. Trainings were also conducted to the whole laboratory for testing team. With these activities, it was possible to develop and deploy the necessary testing procedures in DEC-LEB/EPUSP and validate procedures for testing. An infusion pump for the validation of these procedures was used, along with all its accompanying documents. The final result was the training of DEC-LEB/EPUSP team for testing as new editions of the standards that incorporate Risk Management in their prescriptions, concluding that laboratories for testing must include appropriate procedures and training of their human resources.
8

Gerenciamento de risco aplicado a procedimentos de ensaios de equipamentos eletromédicos. / Risk management applied to testing procedures medical electrical equipment.

Diego Antonio de Oliveira Rosa 16 May 2012 (has links)
Os laboratórios de ensaios, para melhor avaliarem os equipamentos eletromédicos, precisarão implantar no seu sistema de gestão, o processo de Gerenciamento de Risco. Este novo tema está prescrito na edição da Norma ABNT NBR IEC 60601-1:2010 Requisitos Gerais para Segurança Básica e Desempenho Essencial que entrará em vigor a partir de 2012 no Brasil. A presente pesquisa tem como objetivo apresentar resumidamente as etapas do processo utilizado para implantar o Gerenciamento de Risco nos procedimentos de ensaios de equipamentos eletromédicos, visando atender aos novos requisitos da série de Normas ABNT NBR IEC 60601/80601 objetivando a melhoria contínua do Sistema de Gestão de laboratórios de ensaios acreditados pelo INMETRO. O método utilizado para o desenvolvimento deste trabalho consistiu no estudo detalhado das duas edições brasileiras da Norma Geral, de Normas Colaterais, a da Norma Particular de bomba de infusão e controladores, bem como a Norma ABNT NBR ISO 14971:2009. Após o estudo destas Normas, foram analisados alguns arquivos de Gerenciamento de Risco fornecidos por fabricantes de equipamentos eletromédicos e realizado o estudo de algumas ferramentas utilizadas para o desenvolvimento do Gerenciamento de Risco como, por exemplo, FMEA, FTA e HAZOP. Também foram realizados treinamentos com a equipe do laboratório de ensaio para sua capacitação. Com esta série de atividades, foi possível o desenvolvimento e implantação dos necessários procedimentos de ensaios na DEC-LEB/EPUSP e a validação dos mesmos. Para a validação desses procedimentos foi utilizada uma bomba de infusão, juntamente com todos os seus documentos acompanhantes. O resultado final obtido foi a capacitação da DEC-LEB/EPUSP para a realização de ensaios conforme as novas edições das Normas que incorporam Gerenciamento de Risco em suas prescrições, concluindo-se que os laboratórios de ensaios deverão incluir os devidos procedimentos com cuidado e capacitação de seus recursos humanos. / To better evaluate the medical electrical equipment the laboratories for testing will need to deploy in its management system, the process of Risk Management. This new theme is prescribed in the edition of ABNT NBR IEC 60601-1:2010, which will take effect from 2012 in Brazil. This research aims to show brief the process used to implement the Risk Management procedures for testing medical electrical equipment, to meet the new requirements of the series of ABNT NBR IEC 60601/80601 aiming at continuous improvement of the management systems of laboratories for testing accredited by INMETRO. The method used for the development of this research was the detailed study of two Brazilian editions of the General Standard, Collateral Standards, Particular Standard of infusion pumps and controllers, as well as the ABNT NBR ISO 14971:2009. After studying these Standards, some Risk Management files provided by manufacturers of medical electrical equipment were analyzed and performed the study of some tools used for the development of Risk Management, for example, FMEA, FTA and HAZOP. Trainings were also conducted to the whole laboratory for testing team. With these activities, it was possible to develop and deploy the necessary testing procedures in DEC-LEB/EPUSP and validate procedures for testing. An infusion pump for the validation of these procedures was used, along with all its accompanying documents. The final result was the training of DEC-LEB/EPUSP team for testing as new editions of the standards that incorporate Risk Management in their prescriptions, concluding that laboratories for testing must include appropriate procedures and training of their human resources.
9

Obtenção de fios em ligas de cobre para utilização em linhas de transmissão e em eletrodos para contatos elétricos / Obtation of cooper-chromium-zirconium alloy wires for use in electrical transmission lines and electrodes for electrical contacts

SAFRA, LEANDRO C.P.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
10

Obtenção de fios em ligas de cobre para utilização em linhas de transmissão e em eletrodos para contatos elétricos / Obtation of cooper-chromium-zirconium alloy wires for use in electrical transmission lines and electrodes for electrical contacts

SAFRA, LEANDRO C.P.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / O objetivo do presente trabalho consistiu no desenvolvimento de fios de liga de cobre-cromo-zircônio (CuCrZr) em uma composição estabelecida em Cu-0,7%Cr- 0,1%Zr (em massa). Nas etapas desenvolvidas, foram feitos botões de cobrecromo (CuCr) e cobre-zircônio (CuZr) em um forno a arco elétrico de eletrodo não consumível, sendo esses botões, posteriormente, fundidos junto com cargas de cobre em um cadinho de alumina (Al2O3) inserido no interior de um vaso de aço inoxidável, que serviu como suporte. Após a fusão dos botões e cargas, o banho foi vazado em uma coquilha de cobre, obtendo-se os tarugos da liga de cobre. Dos tarugos em estado bruto de fusão, foram retiradas amostras para ensaios de dureza Vickers. Nesses tarugos foi feito um tratamento térmico de homogeneização a 910 °C por 2 h. Os tarugos foram posteriormente trabalhados mecanicamente a frio por forjamento rotativo seguido de trefilação, para obtenção final dos fios no calibre de 2,174 mm. Os fios passaram por dois tratamentos térmicos de recristalização, um a 510 °C por 1 h e outro de 480 °C por 5 h. Os fios foram caracterizados mecanicamente por ensaios de tração e de dureza e os resultados foram comparados com dados experimentais da literatura. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0932 seconds