• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Characterization of a Novel Tubular Carbon Fibre Based Electrode for Dopamine Detection with Fast Scan Cyclic Voltammetry / Karakterisering av en ny tubformad kolfiberbaserad elektrod för dopamindetektion med fast scan cyclic voltammetry

Hansson, Sofia January 2022 (has links)
Fast Scan Cyclic Voltammetry (FSCV) is an electrochemical technique, based on ramping a voltage through a microelectrode and measuring the resulting redox current to obtain information about an electroactive molecule. FSCV can be used for the detection of dopamine, which is a vital neurotransmitter. Dopamine is central to conditions such as Parkinson’s disease. The purpose of this thesis was to evaluate if a new type of highly biocompatible microelectrode, called tube electrode, can be used to detect dopamine using FSCV and determine how they compare to standard carbon fibre microelectrodes (CFMEs). In order to achieve this, three main tasks were set and fulfilled. First, a station for in-vitro FSCV was set up and CFMEs of varying sizes were used to detect dopamine at different concentrations. Secondly, the same trials were done with tube electrodes. Finally, the results of the tubes were compared to the CFMEs. In total, four CFMEs and four tube electrodes were investigated. The dopamine concentrations ranged from 20 nM to 40 μM. In short, the results indicate that the tubes generally have lower sensitivity than the CFMEs but better linearity between the increasing dopamine concentration and the resulting current. The tubes also had a marginally higher concentration threshold for dopamine detection. The main challenge encountered was a decrease in sensitivity over time. Here, further investigations are necessary to map the causes responsible. In conclusion, the tube electrodes are able to detect dopamine in-vitro, with concentrations relevant for in-vivo sensing, with a performance comparable to CFMEs. However, further studies are necessary before the tube electrodes can be used for dopamine detection in-vivo. / Fast Scan Cyclic Voltammerey (FSCV) är en elektrokemisk teknik, baserad på att ändra en spänning genom en mikroelektrod och sedan mäta den resulterande redox-strömmen för att få information om en elektroaktiv molekyl. FSCV kan användas för detektering av dopamin, som är en livsviktig signalsubstans. Dopamin har en central roll vid tillstånd så som Parkinsons sjukdom. Syftet med detta examensarbete var att utvärdera om en ny typ av mycket biokompatibel mikroelektrod, kallad tubelektrod, kan användas för att detektera dopamin genom FSCV och fastställa hur de jämför sig med vanliga kolfibermikroelektroder (KFME). För att uppnå detta sattes och uppfylldes tre huvuduppgifter. Först upprättades en station för in-vitro FSCV där KFME med varierande storlek användes för att detektera olika koncentrationer dopamin. Sedan gjordes samma försök med tubelektroder. Slutligen jämfördes resultaten med de från KFME. Totalt testades fyra KFME och fyra tubelektroder. Dopaminkoncentrationerna sträckte sig från 20 nM till 40 μM. Kort sagt indikerar resultaten att tuberna generellt hade lägre känslighet än KFME men bättre linjäritet mellan den ökande dopaminkoncentrationen och den resulterande strömmen. Tuberna hade även något högre koncentrationströskel för detektionen av dopamin. Den största utmaningen som påträffades var en minskning i känslighet över tid. Här krävs vidare undersökningar för att helt förstå de bakomliggande anledningarna. Slutsatsen är att tuberna kan detektera dopamin in-vitro, med koncentrationer som är relevanta för mätningar in-vivo, och med en prestation jämförbar med den för KFME. Dock krävs mer studier innan tubelektroderna kan användas för att detektera dopamin in-vivo.
2

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Ivama, Viviane Midori 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V ≤ Eapl ≤ 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 ≤ ν ≤ 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, ν = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 ± 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 ± 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 ≤ E ≤ 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 ≤ v ≤ 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 ± 0.2) A mo1-1 L cm-2 and detection limit of (2.5 ± 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
3

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Viviane Midori Ivama 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V ≤ Eapl ≤ 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 ≤ ν ≤ 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, ν = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 ± 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 ± 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 ≤ E ≤ 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 ≤ v ≤ 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 ± 0.2) A mo1-1 L cm-2 and detection limit of (2.5 ± 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
4

Estudos de adsorção e equilíbrio nos sistemas Cd(II) / SCN-/ C6H12N4 e Cd(II)/I-/SCN-. aperfeiçoamento de métodos e eletrodo / Adsorption and equilibrium studies of the systems Cd(II)/SCN-/C6N12H14 and Cd(II)/I-/SCN-. Improvement of methods and of the electrode

Angnes, Lucio 07 December 1987 (has links)
Na presente tese investigou-se a adsorção induzida de um cátion metálico (cádmio(II)) na presença simultânea de dois ligantes (um pseudo-haleto e uma amina ou haleto) na interface eletrodo de mercúrio/solução aquosa, com vistas a uma melhor compreensão desse processo. Os estudos de adsorção foram precedidos por estudos de equilíbrio dos compostos de coordenação formados em solução aquosa. Medidas experimentais foram feitas por potenciometria com eletrodo de amálgama, em força iônica 1,00 M, ajustada com NaCl04. Análise dos dados por programas computacionais adequados levou à quantificação das constantes de estabilidade de 7 espécies binárias e 9 espécies mistas para o sistema Cd(II)/ SCN-/C6H12N4 e de 8 espécies binárias e 6 mistas para o sistema Cd(II)/I-/SCN-, sendo todas estas espécies mononucleares. Para possibilitar um maior grau de automação das medidas cronocoulométricas de adsorção, o eletrodo de gota pendente de mercúrio, anteriormente desenvolvido no IQ-USP, teve seu sistema mecânico aperfeiçoado e passou a ser controlado por computador. O \"software\" se incumbe de calcular e comandar o tempo de abertura da micro-válvula do eletrodo para gerar gotas com a área solicitada. Aproveitando a possibilidade de realizar aquisição (de dados de carga durante e após a formação das gotas de mercúrio, introduziu-se um novo método para corrigir a componente faradaica que interfere nos experimentos de determinação da carga absoluta do eletrodo por extrusão. Após provar o bom funcionamento do método, conseguiu-se a combinação inédita do método de extrusão de gotas com acronocoulometria num único experimento automatizado feito com a mesma gota de mercúrio. Com as informações assim geradas, torna-se possível conhecer e optar entre o potencial e a carga absoluta como parâmetro que define o estado elétrico da interface eletrodo/solução. Com esta combinação de técnicas, foi investigada a adsorção de cádmio induzida por tiocianato e hexametilenotetramina. Este sistema apresentou um interessante comportamento: a hexametilenotetramina, ao contrário do tiocianato, não induz a adsorção de ions cádmio, mas na presença desse pseudo-haleto provoca um intenso reforço na adsorção induzida que pode alcançar um fator de 50 vezes. Também foi possível realizar estimativas sobre as espécies que adsorvem preferencialmente, e da área média ocupada pelos complexos na condição de máxima adsorção. A energia livre de adsorção pode ser estimada pela isoterma de Henry, para baixas concentrações de ligantes. A adsorção de cádmio induzida por iodeto e tiocianato foi investigada de maneira preliminar. Nos estudos deste sistema ficou bem evidenciada a importância da utilização da carga como variável independente, ao invés do potencial. / The induced adsorption of a metallic cation (cadmium (II)) in the presence of two ligands, simultaneously (a pseudo-halide and an amine or halide), has been investigated at the mercury electrode/aqueous solution interface with the purpose of gaining a better understanding about such kind of process. The adsorption studies have been preceded by studies of the equilibria of the coordination compounds formed in aqueous solutions. Experimental measurements have been made by potentiometry with an amalgam electrode with 1,00 M ionic strength adjusted with NaClO4. Analysis of the data with adequated software allowed the quantification of the stability constants of 7 binary and 8 mixed species for the system Cd(II)/ SCN-/C6H12N4</sub and 8 binary and 6 mixed species for the system Cd(II)/I-/SCN-, all species being mononuclear. To provide a greater degree of automation of the chronocoulometric measurements of adsorption, the hanging drop mercury electrode, formely developed at the Chemistry Institute-USP, has had its mechanical parts perfectioned and wasput under computer control. A software was written to calculate and control the opening and closure of the micro-solenoid valve of the electrode to generate drops with the required area. A new method for the correction of the faradaic component that interferes with the absolute electrode charge during extrusion experiments was introduced and applied to charge measurements obtained making data aquisition during and shortly after the drop formation. Once proved that the method works, efforts were directed to combine the extrusion with the chronocoulometric measurements in one automated experiment dane with the same mercury drop. As a result, it is now a simple matter to make a choice between potential or charge on the electrode to define the electric state of the electrode/solution interface. With this combination of techniques, the adsorption of cadmium(II) induced by thiocyanate and hexamethylenetetramine has been investigated. An interesting behavior whas observed: the hexamethylenetetramine alone, doesn\'t induce adsorption of cadmium (II) as does the thiocyanate but provides a strong reinforcement (up to a factor of 50) of the induced adsorption when it is present simultaneously with the pseudo-halide. Some estimatives about the species that can adsorb preferentially has been made, as well as an evaluation of the mean area ocupied by the complexes at the maximum adsorption condition. The free energy of adsorption has been calculated, considering an Henry isotherm for the lowest concentration range. Preliminary studies of the induced adsorption of the Cd(II)/I-/SCN- system revealed a slight reinforcement of the adsorption, when both ligands are presente. The iodide always controls the process. The advantage of using the charge in place of potential as the independent variable is evident for this system.
5

Estudos de adsorção e equilíbrio nos sistemas Cd(II) / SCN-/ C6H12N4 e Cd(II)/I-/SCN-. aperfeiçoamento de métodos e eletrodo / Adsorption and equilibrium studies of the systems Cd(II)/SCN-/C6N12H14 and Cd(II)/I-/SCN-. Improvement of methods and of the electrode

Lucio Angnes 07 December 1987 (has links)
Na presente tese investigou-se a adsorção induzida de um cátion metálico (cádmio(II)) na presença simultânea de dois ligantes (um pseudo-haleto e uma amina ou haleto) na interface eletrodo de mercúrio/solução aquosa, com vistas a uma melhor compreensão desse processo. Os estudos de adsorção foram precedidos por estudos de equilíbrio dos compostos de coordenação formados em solução aquosa. Medidas experimentais foram feitas por potenciometria com eletrodo de amálgama, em força iônica 1,00 M, ajustada com NaCl04. Análise dos dados por programas computacionais adequados levou à quantificação das constantes de estabilidade de 7 espécies binárias e 9 espécies mistas para o sistema Cd(II)/ SCN-/C6H12N4 e de 8 espécies binárias e 6 mistas para o sistema Cd(II)/I-/SCN-, sendo todas estas espécies mononucleares. Para possibilitar um maior grau de automação das medidas cronocoulométricas de adsorção, o eletrodo de gota pendente de mercúrio, anteriormente desenvolvido no IQ-USP, teve seu sistema mecânico aperfeiçoado e passou a ser controlado por computador. O \"software\" se incumbe de calcular e comandar o tempo de abertura da micro-válvula do eletrodo para gerar gotas com a área solicitada. Aproveitando a possibilidade de realizar aquisição (de dados de carga durante e após a formação das gotas de mercúrio, introduziu-se um novo método para corrigir a componente faradaica que interfere nos experimentos de determinação da carga absoluta do eletrodo por extrusão. Após provar o bom funcionamento do método, conseguiu-se a combinação inédita do método de extrusão de gotas com acronocoulometria num único experimento automatizado feito com a mesma gota de mercúrio. Com as informações assim geradas, torna-se possível conhecer e optar entre o potencial e a carga absoluta como parâmetro que define o estado elétrico da interface eletrodo/solução. Com esta combinação de técnicas, foi investigada a adsorção de cádmio induzida por tiocianato e hexametilenotetramina. Este sistema apresentou um interessante comportamento: a hexametilenotetramina, ao contrário do tiocianato, não induz a adsorção de ions cádmio, mas na presença desse pseudo-haleto provoca um intenso reforço na adsorção induzida que pode alcançar um fator de 50 vezes. Também foi possível realizar estimativas sobre as espécies que adsorvem preferencialmente, e da área média ocupada pelos complexos na condição de máxima adsorção. A energia livre de adsorção pode ser estimada pela isoterma de Henry, para baixas concentrações de ligantes. A adsorção de cádmio induzida por iodeto e tiocianato foi investigada de maneira preliminar. Nos estudos deste sistema ficou bem evidenciada a importância da utilização da carga como variável independente, ao invés do potencial. / The induced adsorption of a metallic cation (cadmium (II)) in the presence of two ligands, simultaneously (a pseudo-halide and an amine or halide), has been investigated at the mercury electrode/aqueous solution interface with the purpose of gaining a better understanding about such kind of process. The adsorption studies have been preceded by studies of the equilibria of the coordination compounds formed in aqueous solutions. Experimental measurements have been made by potentiometry with an amalgam electrode with 1,00 M ionic strength adjusted with NaClO4. Analysis of the data with adequated software allowed the quantification of the stability constants of 7 binary and 8 mixed species for the system Cd(II)/ SCN-/C6H12N4</sub and 8 binary and 6 mixed species for the system Cd(II)/I-/SCN-, all species being mononuclear. To provide a greater degree of automation of the chronocoulometric measurements of adsorption, the hanging drop mercury electrode, formely developed at the Chemistry Institute-USP, has had its mechanical parts perfectioned and wasput under computer control. A software was written to calculate and control the opening and closure of the micro-solenoid valve of the electrode to generate drops with the required area. A new method for the correction of the faradaic component that interferes with the absolute electrode charge during extrusion experiments was introduced and applied to charge measurements obtained making data aquisition during and shortly after the drop formation. Once proved that the method works, efforts were directed to combine the extrusion with the chronocoulometric measurements in one automated experiment dane with the same mercury drop. As a result, it is now a simple matter to make a choice between potential or charge on the electrode to define the electric state of the electrode/solution interface. With this combination of techniques, the adsorption of cadmium(II) induced by thiocyanate and hexamethylenetetramine has been investigated. An interesting behavior whas observed: the hexamethylenetetramine alone, doesn\'t induce adsorption of cadmium (II) as does the thiocyanate but provides a strong reinforcement (up to a factor of 50) of the induced adsorption when it is present simultaneously with the pseudo-halide. Some estimatives about the species that can adsorb preferentially has been made, as well as an evaluation of the mean area ocupied by the complexes at the maximum adsorption condition. The free energy of adsorption has been calculated, considering an Henry isotherm for the lowest concentration range. Preliminary studies of the induced adsorption of the Cd(II)/I-/SCN- system revealed a slight reinforcement of the adsorption, when both ligands are presente. The iodide always controls the process. The advantage of using the charge in place of potential as the independent variable is evident for this system.

Page generated in 0.0717 seconds