• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 11
  • 6
  • 6
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Especiação de mercurio em solos contaminados por analise de termodessorção acoplada a absorção atomica

Windmoller, Claudia Carvalhinho 21 July 2018 (has links)
Orientador: Wilson de Figueiredo Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-21T09:43:18Z (GMT). No. of bitstreams: 1 Windmoller_ClaudiaCarvalhinho_D.pdf: 3136554 bytes, checksum: 5c92be66556b1873f44c96fdda3b07ca (MD5) Previous issue date: 1996 / Doutorado
2

"Determinação quantitativa de compostos peraloginados do tipo CxBryCL2(onde x=1 ou 2; y+z=4 ou 6) por cromatografia liquida de alta eficiencia

Morgano, Marcelo Antonio 21 July 2018 (has links)
Orientador: Carol Hollingworth Collins / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-21T15:48:01Z (GMT). No. of bitstreams: 1 Morgano_MarceloAntonio_M.pdf: 1698018 bytes, checksum: 76570abe50e9f7104334fedca574d2ba (MD5) Previous issue date: 1996 / Mestrado
3

Desenvolvimento metodologico para quantificação de minociclina em plasma humano : analise realizada pela tecnica de High Performance Liquid Chromatography (HPLC) acoplada a espectrometria de massas

Araujo, Marcus Vinicius Ferreira de 12 May 2002 (has links)
Orientador: Gilberto de Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T01:29:51Z (GMT). No. of bitstreams: 1 Araujo_MarcusViniciusFerreirade_M.pdf: 3547174 bytes, checksum: c313e1b0eb5e1f1fee5ad91c8cd8b066 (MD5) Previous issue date: 2002 / Resumo: o objetivo deste trabalho foi desenvolver um método sensível para quantificar minociclina em plasma humano. A minociclina foi quantificada em plasma humano pela técnica de cromatografia líquida acoplada ao espectrômetro de massas (LC-MS/MS), usando a claritromicina como padrão interno. A minociclina e o padrão interno - claritromicina, foram extraídos de plasma humano através de uma extração líquido-líquido composta de Diethyléter/diclorometano (70:30). Após a retirada do solvente, os fármacos foram dissolvidos em um pequeno volume de fase móvel, sendo que uma alíquota desta amostra foi analisada por cromatografia líquida de fase reversa acoplada ao espectrômetro de massas sequencial no modo "eletrospray" positivo, sendo o íon filho monitorado, previamente selecionado no modo de monitoração de reação múltipla (MRM). O método foi considerado rápido ( extração líquida simples e tempo de corrida inferior a 3 minutos) e sensível ( limite de quantificação de 5 ng/mL), e sendo empregado em estudo de bioequivalencia de duas formulações de concentração 100 mg em 24 voluntários sadios / Abstract: The objective of this work was to develop a suitable method for measurement of minocycline in human plasma. Minocycline was determined in human plasma by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) using clarithromycin as an internal standard. Minocycline and the internal standard Clarithromycin are extracted from human plasma by liquid-liquid extraction using a mixture of Dlethyl-eter/Diclorometane (70:30). Afier removal of the solvent, the analytes were dissolved in a small volume of mobile phase, an aliquot of which was analyzed by combined reversed phase liquid chromatography tandem mass spectrometry with positive ion electrospray ionization using selected daughter ion monitoring (MRM). The method was considered fast (single liquid extraction and run time of < 3 min) and sensitive (limit of quantitation of 5 ng/ml) and it was employed in a bioequivalence study of two 100mg tablet formulations in 24 healthy volunteers / Mestrado / Farmacologia / Mestre em Farmacologia
4

Determinação por cromatografia gasosa de alguns poluentes halogenados pouco volateis em agua

Rocha, Eduardo Carasek da 19 July 2018 (has links)
Orientador : Antonio Luiz Pires Valente / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-19T03:05:56Z (GMT). No. of bitstreams: 1 Rocha_EduardoCarasekda_M.pdf: 5109549 bytes, checksum: 78572e4290a3ae50d886e555bec8167e (MD5) Previous issue date: 1994 / Mestrado
5

Manipulação gravimetrica automatica de soluções

Cunha, Ildenize B. S 19 July 2018 (has links)
Orientador : Celio Pasquini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-19T09:32:16Z (GMT). No. of bitstreams: 1 Cunha_IldenizeB.S_D.pdf: 5906129 bytes, checksum: 0f1152ff9ea91e411c561d088124cbfb (MD5) Previous issue date: 1994 / Doutorado
6

Análise químico-farmacêutica da buspirona / Chemical-pharmaceutical analysis of buspirone

Haraguchi, Toshio 12 September 1990 (has links)
A buspirona, ansiolítico da segunda geração usada no tratamento de ansiedade, foi analisada fisico-quimica e quimicamente, com o objetivo de fornecer subsídios para a respectiva monografia. Fizeram-se os seguintes testes de caracterização deste fármaco: faixa de fusão, análise elementar, pH, umidade e solubilidade. Realizaram-se igualmente as provas de identificação constante de: análise cromatográfica, ensaio de cloreto, espectro no infravermelho, espectro no ultravioleta, espectro de ressonância magnética protônica, espectro de massa, espectro de carbono-13, termogravimetria, calorimetria exploratória diferencial e cromatografia líquida de alta resolução. Efetuaram-se, também, determinações quantitativas pelos seguintes métodos: micro-Kjeldahl, gravimétrico, potenciométrico com nitrato de prata, doseamento com ácido perclórico em meio acetico por volumetria e potenciometria e espectrofotométrico no ultravioleta. Concluiu-se que: 1) o teste de caracterização mais indicado e o ponto de fusão; 2) das provas de identificação, as mais simples e rápidas são as seguintes: identificação de cloreto, infravermelho e ultravioleta; 3) dos métodos de determinação quantitativa, mais prático e o doseamento com ácido perclórico em meio acético, usando como indicador o vermelho de quinaldina. / Buspirone, a new non-benzodiazepine anxiolytic agent which is effective in the treatment of anxiety, was analyzed by physicochemical and chemical methods, having in mind a monograph of this drug. The fo1lowing characterization tests of this drug were performed: melting range, elementary analysis, pH, loss in drying, solubility. The following identification tests were also carried out: chromatographic analysis, identification of chloride, infrared absorption, ultraviolet absorption, protonic magnetic resonance spectra, mass spectrum, carbon 13C NMR spectroscopy, thermogravimetry and high performance liquid chromatography. Quantitative determinations were obtained through the following methods: micro-Kjeldahl, gravimetry, potenciometry, non-aqueous titration with perchloric acid and ultraviolet spectrometry. The following conclusions were reached: 1) the best characterization test is the melting range; 2) the simplest and quickest tests of identification are: identification of chloride, infrared and ultraviolet spectrophotometry; 3) the most practical method is the non-aqueous assay with perchloric acid.
7

Análise químico-farmacêutica da buspirona / Chemical-pharmaceutical analysis of buspirone

Toshio Haraguchi 12 September 1990 (has links)
A buspirona, ansiolítico da segunda geração usada no tratamento de ansiedade, foi analisada fisico-quimica e quimicamente, com o objetivo de fornecer subsídios para a respectiva monografia. Fizeram-se os seguintes testes de caracterização deste fármaco: faixa de fusão, análise elementar, pH, umidade e solubilidade. Realizaram-se igualmente as provas de identificação constante de: análise cromatográfica, ensaio de cloreto, espectro no infravermelho, espectro no ultravioleta, espectro de ressonância magnética protônica, espectro de massa, espectro de carbono-13, termogravimetria, calorimetria exploratória diferencial e cromatografia líquida de alta resolução. Efetuaram-se, também, determinações quantitativas pelos seguintes métodos: micro-Kjeldahl, gravimétrico, potenciométrico com nitrato de prata, doseamento com ácido perclórico em meio acetico por volumetria e potenciometria e espectrofotométrico no ultravioleta. Concluiu-se que: 1) o teste de caracterização mais indicado e o ponto de fusão; 2) das provas de identificação, as mais simples e rápidas são as seguintes: identificação de cloreto, infravermelho e ultravioleta; 3) dos métodos de determinação quantitativa, mais prático e o doseamento com ácido perclórico em meio acético, usando como indicador o vermelho de quinaldina. / Buspirone, a new non-benzodiazepine anxiolytic agent which is effective in the treatment of anxiety, was analyzed by physicochemical and chemical methods, having in mind a monograph of this drug. The fo1lowing characterization tests of this drug were performed: melting range, elementary analysis, pH, loss in drying, solubility. The following identification tests were also carried out: chromatographic analysis, identification of chloride, infrared absorption, ultraviolet absorption, protonic magnetic resonance spectra, mass spectrum, carbon 13C NMR spectroscopy, thermogravimetry and high performance liquid chromatography. Quantitative determinations were obtained through the following methods: micro-Kjeldahl, gravimetry, potenciometry, non-aqueous titration with perchloric acid and ultraviolet spectrometry. The following conclusions were reached: 1) the best characterization test is the melting range; 2) the simplest and quickest tests of identification are: identification of chloride, infrared and ultraviolet spectrophotometry; 3) the most practical method is the non-aqueous assay with perchloric acid.
8

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Ivama, Viviane Midori 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V &#8804; Eapl &#8804; 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 &#8804; &#957; &#8804; 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, &#957; = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 &#177; 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 &#177; 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 &#8804; E &#8804; 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 &#8804; v &#8804; 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 &#177; 0.2) A mo1-1 L cm-2 and detection limit of (2.5 &#177; 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
9

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Viviane Midori Ivama 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V &#8804; Eapl &#8804; 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 &#8804; &#957; &#8804; 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, &#957; = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 &#177; 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 &#177; 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 &#8804; E &#8804; 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 &#8804; v &#8804; 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 &#177; 0.2) A mo1-1 L cm-2 and detection limit of (2.5 &#177; 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
10

Emprego de análise por injeção seqüencial (SIA) com detecção eletroquímica na determinação de metais pesados extraíveis de sedimentos / The use of sequential injection analysis with electrochemical detection for determination of heavy metals extractable from sediments

Silva, Clóvis Lúcio da 26 March 1999 (has links)
Estudou-se a especiação dos metais pesados (Cu, Cd, Cr, Zn, Pb e Ni) em sedimentos do rio Tietê, coletados nos reservatórios de Rasgão, Tecelagem e Barra Bonita. Para isto, adotou-se o protocolo de extração seqüencial proposta por Community Bureau of Reference (BCR), que consiste em três etapas de tratamento, as soluções extratores utilizados foram: etapa 1, solução de ácido acético 0,11 mol/L; Etapa 2, solução de cloridrato de hidroxilamina 0,1 mol/L pH 2 (ajustado com HNO3); Etapa 3, ataque com peróxido de hidrogênio em meio ácido e posterior extração dos metais com solução de acetato de amônio pH 2 (ajustado com HNO3). Nas mesmas amostras efetuou-se uma extração com ácido clorídrico 0,1 mol/L, no sentido de avaliar a concentração de metais potencialmente biodisponíveis. Realizou-se ainda a determinação do teor total de metais. Tanto a extração seqüencial como a extração parcial em ácido diluído foram conduzidas em ambientes anaeróbico (mantendo o EH da amostra) e aeróbicos (após secagem em estufa - simulando material dragado e depositado às margens do rio). As concentrações dos metais presentes nos extratos foram determinadas através das técnicas de absorção atômica, espectrometria de emissão atômica, voltametria de redissolução anódica com eletrodo de gota pendente e a técnica proposta por este trabalho, voltametria de redissolução anódica com eletrodo de filme de mercúrio acoplada ao sistema de injeção seqüencial. A técnica de voltametria de redissolução anódica acoplada ao sistema de injeção sequencial apresentou vantagens em relação a voltametria de redissolução com eletrodo de gota pendente, apresentando maior reprodutibilidade e sensibilidade, redução do tempo de análise e consumo de reagentes, e completa automação dos parâmetros instrumentais, como: vazão, número de reagentes, volumes e seqüência dos reagentes aspirados. / Speciation of heavy metals (Cu, Pb, Cd, Zn, Ni and Cr) in sediments of the Tietê river (SP), collected at Rasgão, Tecelagem e Barra Bonita reservoirs, was studied by the sequential extraction protocol proposed by the Community Bureau of Reference (BCR). This protocol is composed of three steps, that use the following reagent extractors. Step1: 0,11 mol/L acetic acid. Step 2: Hydroxylamine hydrochloride, acidified to pH 2 with nitric acid. Step 3: Oxidation with acidified 30 % (v/v) hydrogen peroxide followed by extraction with 1mol/L ammonium acetate acidified to pH 2 with nitric acid. Samples were also extracted with 0.10 mol/l hydrochloric acid in order to evaluate the bioavailable metal concentrations. The total concentration of metals was also determined. The sequential extraction and the extraction with hydrochloric acid were performed in anoxic (keeping the negative Eh of samples, as in the time of sampling) and oxidant conditions (after drying samples at 60&#186;C in the atmosphere, simulating dredged material). Metal determination was performed by Flame Atomic Absorption Spectrometry (FAAS), Induced Coupled Plasma-Atomic Emission Spectrometry (ICP-EAS), Anodic Stripping Voltammetry with the Mercury Hanging Drop Electrode (ASV-HMDE), and the technique proposed in this work: ASV automated by Sequential Injection (ASV-SI) using the Thin Film Mercury Electrode (TFME). The proposed technique presented improved reproducibility and shorter time of analysis in comparison to conventional ASV-HMDE. In addition, the ASV-SI permits easy and fast change of operational parameters such as flow rate and sample volume, that have direct influence on the deposition time.

Page generated in 0.1289 seconds