Spelling suggestions: "subject:"eletromiografia"" "subject:"eletromiografica""
141 |
Estudo eletromiografico de musculos do sistema estomatognatico durante a mastigação de diferentes materiaisBiasotto, Daniela Aparecida 02 November 2000 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T03:24:01Z (GMT). No. of bitstreams: 1
Biasotto_DanielaAparecida_M.pdf: 2842575 bytes, checksum: feb2616d252c3d3743c0889f8eeb8923 (MD5)
Previous issue date: 2000 / Resumo: O objetivo deste estudo foi comparar o comportamento de alguns dos principais músculos da mastigação (M. temporal, porção anterior, M. masséter e MM. suprahióideos), com a utilização de duas marcas comerciais de goma de mascar A e B e dois materiais insípidos, Rolinho de Algodão e Parafilm.M.@, através de análise dos sinais eletromiográficos. Participaram deste estudo dez (10) voluntários, do sexo feminino, adulto/jovem, com idade variando 18 a 27 anos, com normo oclusão, e sem história de disfunção craniomandibular. A atividade mastigatória foi realizada com o voluntário sentado com o plano de Frankfurt posicionado paralelo ao solo. Para tanto, foram realizados exames eletromiográficos dos mm. temporais, porção anterior e masséteres, bilaterais e supra-hióideos, bilateralmente; utilizando-se mini eletrodos passivos de superfície. Os voluntários foram orientados a mastigar bilateral e simultaneamente cada um dos produtos, em seqüência aleatória. Para o estudo da atividade mastigatória os traçados eletromiográficos foram tratados através de retificação, envoltório linear e normalização, de forma que o coeficiente de variação resultante do processamento fosse analisada comparativamente. Todos os dados foram tratados pela Análise de Variância Univariada e Multivariada. Os resultados do estudo demostrou que não existiu diferença estatística fortemente significativa entre o material Rolinho de Algodão e Parafilm. Estes produtos revelam que no contexto geral ambos são indicados para execução do exame eletromiográfico, pois apresenta menor variação com relação aos demais produtos / Abstract: The purpose of this study was to investigate and to compare the behavior of the chewing muscles (M.Temporales, anterior portion, M.Masseter and M.Suprahyoid), through the use to two chewing gums commercial A and B and two insipid product, Cotton Sal! and Parafilm.M.@, with the objective of analysis of the electromyographyc trace. A total of 10 young adults subjects, of the female sex, with an age ranger from 18 to 27 years, with normal Angle's class I occlusion assessed by intra-oral examination. No signs or symptoms of stomatognathic dysfunctions or other general disease affecting the neuromuscular system were presented. The chewing activity was accomplished with subjects were confortably seat in straight-backed chairs with head unsupported and positioned so that the Frankfort plane was parallel to the floor. For this EMG took place, using bipolar electrodes surface, positioned on the anterior temporal, masseter, bilateral!y, and suprahyod muscles. The subjectives were guided to chew bilaterally and simultaneously each one of the products, in aleatory sequence. For study for the masticatory activity were the electromyographyc signals were processed by fullwave rectification, linear enveloped and normalisation, so that the coefficient of variation (CV%) of chewing activity. The statistic method used was the data based on by the Analysis of Variation. The results of this research demonstrated that didn't exist statistical significant difference between the Cotton Sal! And Parafilm.M.@ / Mestrado / Anatomia / Mestre em Biologia e Patologia Buco-Dental
|
142 |
Avaliação eletromiografica computadorizada dos musculos masseter e temporal fasciculo anterior de pacientes com alterações funcionais do sistema estomatognatico, tratados com aparelhos de superficie oclusal planaLandulpho, Alexandre Brait 27 November 2000 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T06:51:00Z (GMT). No. of bitstreams: 1
Landulpho_AlexandreBrait_M.pdf: 3747636 bytes, checksum: 1d917df938000228d24744d6fbcfb77c (MD5)
Previous issue date: 2000 / Resumo: A proposta do estudo foi avaliar a efetividade da terapia por aparelhos oclusais, em pacientes com alterações funcionais do sistema estomatognático, através da eletromiografia computadorizada. Foram examinados vinte e dois pacientes com sinais e sintomas de alterações funcionais do sistema estomatognático, de ambos os sexos, com idade entre 18 e 53 anos.As avaliações eletromiográficas foram realizadas antes do tratamento e após 90, 120, e 150 dias de utilização dos aparelhos de superfície oclusal plana, sendo que os mesmos receberam modificações (guia em canino e em grupo) nos dias 90 e 120 respectivamente. Os dados coletados foram agrupados em quadros e submetidos à análise estatística de regressão polinomial. Os resultados obtidos revelaram que: na posição de repouso, para o músculo temporal anterior, houve uma redução significativa na atividade eletromiográfica durante o período de tratamento; no fechamento da mandíbula sem resistência, para os músculos masseter e temporal anterior, houve reduções significativas na atividade eletromiográfica; e no fechamento da mandíbula com resistência, para o músculo masseter, houve uma redução significativa na atividade eletromiográfica. A guia em grupo produziu uma menor atividade eletromiográfica, em repouso para o músculo temporal anterior, no fechamento sem resistência para os músculos masseter e temporal anterior, e Fno fechamento com resistência para o músculo masseter / Abstract: The purpose of this study was to evaluate, through computerized electromyography, the effectiveness of occlusal splints therapy, used by patients with functional alterations of the stomatognatic system. Twenty two patients, of both sex, aged between 18 and 53 years old, with signs and symptoms of the refered functional alterations, were examinated. The electromyographic evaluations were realized before the beginning of the treatment and 90, 120, 150 days after using the occlusal plane surface splints. It is important to emphasize that these splints received canine guidance and group function modification at the 90th and 120th day, respectively. The collected informations were submited to statistical analysis of polinomial regression, and revealed that the anterior temporal muscle, in rest position, had an expressive reduction in electromyographic activity during the treatment. The same fact occurried for the masseter and anterior temporal muscles, in movements of closing the mandible with no resistence. Even the masseter muscle, during the movement of closing with resistence, had a significant reduction in electromyographic activity. The group guidance produced a minor electromyographic activity for the anterior temporal muscle, in rest position. It also produced the same situation at closing movement, with no resistence, for the masseter and anterior temporal muscles, and at closing movement with resistence, for the masseter muscle / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
143 |
Avaliação eletrognatografica e eletrosonografica computadorizada de pacientes tratados com aparelhos de superficie oclusal planaSantos, Sidney Saint'Clair 14 March 2001 (has links)
Orientador : Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T03:52:05Z (GMT). No. of bitstreams: 1
Santos_SidneySaint'Clair_M.pdf: 3614938 bytes, checksum: 9b9aafc94d4daca6a82f4cc7c4178290 (MD5)
Previous issue date: 2001 / Resumo: Este trabalho consistiu em avaliar a amplitude dos ruídos nas articulações temporomandibulares, através de eletrosonografia computadorizada e a máxima abertura no plano sagital e os desvios laterais no plano frontal, por meio de eletrognatografia computadorizada. Ambas análises realizadas em pacientes portadores de alterações funcionais do sistema estomatognático, tratados com aparelhos de superfície oclusal plana, com guias em canino e em incisivo. A amostra estudada foi composta de 15 pacientes, 3 do sexo masculino e 12 do sexo feminino, entre 18 e 50 anos, selecionados e encaminhados ao CET ASE (Centro de Tratamento das Alterações do Sistema Estomatognático). As avaliações foram realizadas antes e com 30, 60, 90, 120 dias após a instalação dos aparelhos oclusais. Os dados obtidos foram agrupados em tabelas e submetidos à análise estatística através de regressão polinomial. Os resultados obtidos demonstraram que houve diferenças estatisticamente significativas para os valores de abertura máxima, registrados antes e após o tratamento. Os desvios laterais registrados no plano frontal, tanto para o lado esquerdo quanto para o direito, não demonstraram diferenças significativas. Com relação à amplitude dos ruídos articulares houve diminuição em função da terapêutica instituída, entretanto, diferenças estatisticamente significativas foram constatadas apenas nas articulações do lado esquerdo / Abstract: The aim of this study was to evaluate the amplitude of the the temporomandibular joint sounds, by means of a computerized eletrosonograph; and the amplitude, on the saggital plane and deviations, on the frontal plane; through computerized kinesiograph on patients with temporomandibular disorders treated with occlusal splints. A group of 15 patients was studied, 3 males and 12 females, between 18 and 50 years-old, selected and sent to CETASE (Temporomanibular Disorders Treatment Center). The patients had painful symptoms of temporomandibular disorders, and were treated with occlusal splints, modified through the treatment, receiving incisor and canine guidance. Evaluations were carried out before, 30, 60, 90 and 120 days after the occlusal splints placement. The results showed a statistically significant difference higher amplitude on maximal open mouth. For the lateral deviations, both right and left, a reduction was noticed, however, there were no statistical significant differences. For the amplitude of the temporomandibular noises, a reduction was noticed, h oweve r, only the left joint presented statistical significant differences. In conclusion, the occlusal splints proved to be effective in the temporomandibular disorders treatment, regarding the amplitude on maximal open mouth and on the reduction of joint noises / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
144 |
Analise eletromiografica dos musculos masseter e temporal durante atividade mastigatoria em portadores de disfunção temporomandibularCaria, Paulo Henrique Ferreira, 1972- 10 October 2001 (has links)
Orientador : Heloisa A. Lima Castro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:39:08Z (GMT). No. of bitstreams: 1
Caria_PauloHenriqueFerreira_D.pdf: 2506387 bytes, checksum: 4ed6b549186513c6cfadd7c6a14e251c (MD5)
Previous issue date: 2001 / Resumo: O objetivo da presente pesquisa foi avaliar a atividade, o padrão, a freqüência mediana e o coeficiente de inclinação da reta de regressão linear do espectrograma (SLOPE) do sinal eletromiográfico dos músculos masseter e porção anterior do temporal de voluntários portadores de disfunção temporomandibular (DTM) e clinicamente normais. Foram avaliados 20 voluntários do sexo feminino, divididos em dois grupos. O grupo DTM foi constituído por dez portadores de DTM miogênica, com idade entre 20 e 33 anos (x=24,6 e DP=4,19) e o grupo CONTROLE, indivíduos considerados clinicamente normais em avaliação prévia, com idade entre 21 e 27 anos (x=23,8 e DP=1,68). Todos assinaram o consentimento formal de participação (CNS 196/96). Os sinais eletromiográficos foram captados por eletrodos ativos diferencias de superfície com impedância de entrada de lOGO, CMRR de 130 dB e 2 picofaraday, e ganho de 100 vezes. Os traçados eletromiográficos foram registrados utilizando-se um eletromiógrafo composto por módulo condicionador de sinas de 16 canais, e placa AID de 12 bites de resolução de faixa dinâmica, filtro do tipo Butterworth, de passa-baixa de 509 Hz, de passa-alta de 10,6 Hz, ganho 10 vezes e freqüências de amostragem de 1.000 Hz. Para observar o comportamento das diferentes variáveis estudadas, os sinais esletromiográficos foram tomados em 3 diferentes intervalados do tempo que incluíram sempre 3 ciclos mastigatórios do abaixamento a elevação da mandíbula. O primeiro intervalo de tempo compreendeu os três primeiros ciclos completos compreendidos entre o instante inicial do registro até 4 segundos. No segundo intervalo foram calculados os valores de amplitude eletromiográfica dos 3 ciclos mastigatórios completos registrados após o 5° segundo de coleta. Por fim, o terceiro intervalo de análise, incluiu os três últimos ciclos mastigatórios completos compreendidos entre o 11° e 15° segundos. Foram avaliados os valores da Root Mean Square (RMS), da freqüência mediana, o SLOPE e o padrão de ativação dos músculos estudados, utilizando os testes estatísticos de Kolmogorov-Smirnov, para avaliar a nonna1idade de distribuição dos dados; o teste T de Student não pareados, para comparar valores entre os dois grupos de estudo; e o teste de Kruskal-Wallis para análise de variância dos dados de cada um dos grupos de estudo. Foram considerados valores de p significativos aqueles menores que 5%. Quando os valores médios de RMS normalizados pela contração isométrica voluntária máxima e freqüência mediana, do grupo DTM e CONTROLE, foram comparados entre músculos nenhuma diferença estatística significativa foi observadas para nenhum dos intervalos de tempo selecionados (p> 0.05). Os valores de RMS normalizados e de freqüência mediana, de cada um dos músculos, também foram pareados por músculos do grupo CONTROLE e DTM e nenhuma diferença estatisticamente significativa (p> 0.05) foi encontrada em nenhum dos trechos de tempo estudados. Os valores do SLOPE do grupo CONTROLE apresentaram um padrão regular entre os músculos, sendo negativos no primeiro intervalo de análise, positivo no segundo e novamente negativo no fim do registro. O grupo DTM apresentou, em todos os intervalos de tempo analisados, valores negativos de SLOPE. A avaliação dos coeficientes de variação dos envoltórios lineares mostrou elevada variação no padrão de ativação dos diferentes músculos estudados tanto no grupo CONTROLE quanto no grupo DTM. Nestas condições experimentais é possível concluir que um período de 15 segundos de mastigação não foi suficiente para evidenciar sinais de fadiga muscular, em nenhum dos grupos de estudo, de acordo com o comportamento das variáveis estudadas. Os valores do SLOPE encontrados neste estudo sugerem que o grupo DTM e o grupo controle apresentam diferente tendências de recrutamento das unidades motoras dos músculos mastigatórios, ou ainda um alteração na proporção de unidades motoras do tipo I e do tipo II. A não diferença dos valores de RMS entre os grupos de estudo ressalta a grande variedade de combinações de músculos hipoativos e hiperativos em portadores de DTM e a necessidade de uma abordagem individualizada na assistência destes pacientes. A grande variação nos padrões de ativação ao longo dos registros sugere diferentes estratégias para a realização de uma mesma tarefa motora e merece mais estudos que compare a eficiência da mastigação entre grupos clinicamente normais e com DTM / Doutorado / Doutor em Biologia Buco-Dental
|
145 |
Estudo eletromiografico dos musculos orbiculares da boca e mentoniano, em portadores de maloclusão classe II, divisão 1 de Angle tratados com aparelhos ortopedico de BimlerTeixeira, Luis Fernando Lorenzi 14 August 2018 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas . Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T20:07:46Z (GMT). No. of bitstreams: 1
Teixeira_LuisFernandoLorenzi_M.pdf: 2824595 bytes, checksum: 15811f9b54de270d9a55308913ca2f5f (MD5)
Previous issue date: 1997 / Resumo: Analisou-se o comportamento eletromiográfico dos músculos orbiculares superior e inferior da boca, porção medial e mentoniano em indivíduos jovens portadores de maloclusão Classe" divisão 1 de Angle com e sem o uso do aparelho ortopédíco funcional de BIMLER. Para tanto foram selecionados 5 pacientes sendo 1 do sexo masculino e 4 do sexo feminino com idade variando entre 10 e 12 anos. As atividades eletromiográficas destes músculos foram feitas em oclusão habitual e durante a deglutição de saliva nos perfodos de 18 hora, 1 semana, 1 mês, 3 meses e 6 meses. Os dados obtidos foram submetidos à análise de variâncía e para a comparação das médias duas a duas foi usado o teste de Tukey. Foram feitas também distribuição de frequências baseadas na escala de níveis de intensidade em microvolts segundo BASMAJIAN ( 1974 ). Os resultados revelaram que, existem diferenças no foncionamento dos músculos orbiculares da boca, porção medial, segmento superior e inferior entre os indivíduos classe li, divisão 1 de Angle durante o uso do aparelho; o segmento inferior tem uma participação mais efetiva em relação ao músculo orbicular superior, tanto em oclusão habitual quanto em deglutiçAo de saliva; durante a deglutlção de saliva os pacientes apresentaram uma atividade muito forte dos músculos mentoniano e segmento Inferior do orblcular da boca. Os músculos estudados revelaram, que em oclusão habitual e com o aparelho, as suas atividades- elétricas aumentam no 1° mês e diminuem significativamente no 3° e 6° mês de uso. Os pacientes sem o uso do aparelho funcional de BIMLER sempre mostraram que os potenciais de ação são menores que aqueles verificados com o aparelho, em todos os períodos estudados. Existe uma tendência de adaptação da atividade elétrica dos músculos peribucais ( orbiculares superior e inferior e mentoniano ) após o 6° mês do uso do aparelho funcional de BIMLER. / Abstract: Analysis of eletromiographic function of the mouth superior and inferior orbicular muscles, middle portion and mentonian in young patients with malocclusion class li, division 1 according to Angle with and without an ortopedic functional device of BIMLER. For This purpose 5 patients were selected, 1 male and 4 female with ages between 10 and 12. Muscular eletromiography activities were measured in usual oclussion and while swallowing saliva in the periods of 1 day, 1 week, 1 month, 3 months and 6 months. Data were submitted to varation analysis and results compared two by two according to Tukey. Iso the frequency distribution based in a intensity levels scale in microvolts according to Basmajian (, 1974 ) was made. Results showed significant differents in the activity of moutt1 orbicular muscle, middle portion, superior and inferior segments among the patients class 11, division 1 according to Angle while wearing the device, the inferior segment has a more effective function in relation to the superior orbicular muscle, as in usual occlusion as while swallowing saliva; in this period patients showed a very strong mentonian muscle and inferior segment of mouth orbicular activity. The studied muscles showed that in usual occlusion and with the device, electrial activltjes increase in the first month and decrease a lot in the 3rd and 6th month of use. Patients IIÍthout the BIMLER functional device showed action potentials smaller tha" the ones with the device, in ali the periods studied. There is a tendency to adapt the electrial activity from peribucal muscles ( superior and inferior o,picular and mentonian ) after the 6th month of use of the BIMLER functional device. / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Ciências
|
146 |
Mechanism of Muscle Vibrations During Stimulated and Voluntary Isometric Contractions of Mammalian Skeletal MuscleVaz, Marco Aurelio January 1996 (has links)
When a muscle contracts it produces vibrations. The origin of these vibrations is not known in detail. The purpose of this study was to determine the mechanism associated with muscle vibrations. Mechanisms which have been proposed in the literature were described as theories (cross-bridge cycling, vibrating string and unfused motor unit theories). Specific predictions were derived from each theory, and tested in three conceptually different studies. In the first study, the influence of recruitment strategies of motor units (MUs) on the vibromyographic (VMG) signal was studied in the in-situ cat soleus using electrical stimulation of the soleus nerve. VMG signals increased with increasing recruitment and decreased with increasing firing rates of MUs. Similar results were obtained for the human rectus femoris (RF) muscle using percutaneous electrical stimulation of the femoral nerve. The influence of MU activation on muscle vibrations was studied in RF by analyzing VMG signals at different percentages (0-100%) of the maximal voluntary contraction (MVC). In our second study, we tested the effects of changing the material properties of the in-situ cat soleus (through muscle length changes) on the VMG signal. The magnitude of the VMG signal was higher for intermediate muscle lengths compared to the longest and the shortest muscle lengths. The decreased magnitude of the VMG signal at the longest and at the shortest muscle lengths was associated with increased passive stiffness and with decreased force transients during unfused contractions, respectively. In the third study, the effect of fatigue on muscle vibrations was studied in human RF and vastus lateralis (VL) musc1es during isometric voluntary contractions at a leveI of 70% MVC. A decrease in the VMG signal magnitude was observed in RF (presumably due to derecruitment of MUs) and an increase in VL (probably related to the enhancement of physiological tremor, which may have occurred predorninantly in a mediolateral direction) with fatigue. The unfused MU theory, which is based on the idea that force transients produced by MUs during unfused tetanic contraction is the mechanism for muscle vibrations, was supported by the results obtained in the above three studies.
|
147 |
Efeitos da manipulação na articulação sacroilíaca e transição lombossacral sobre os sinais de indivíduos portadores de instabilidade do tornozelo / Effects of manipulation on sacroiliac joint anda lumbossacral transition on the signs in individuals with ankle sprainBortolazzo, Gustavo Luiz, 1980- 24 August 2018 (has links)
Orientador: Delaine Rodrigues Bigaton / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T17:15:09Z (GMT). No. of bitstreams: 1
Bortolazzo_GustavoLuiz_D.pdf: 1200256 bytes, checksum: d8f50a900626544be31afd4b832b338b (MD5)
Previous issue date: 2014 / Resumo: A manipulação articular é uma técnica utilizada na área de reabilitação física com o objetivo de aumentar a mobilidade articular e gerar respostas reflexas para diminuir a dor, melhorar o controle motor e a flexibilidade. Indivíduos com instabilidade do tornozelo apresentam alteração do controle motor no membro inferior homolateral ao tornozelo instável e alteração do controle postural, o que pode alterar a simetria entre os músculos posturais. A tese está apresentada em formato alternativo, com apresentação de 3 artigos, que têm como objetivos avaliar o efeito da técnica de manipulação articular na sacroilíaca e transição lombossacral sobre a atividade elétrica dos músculos que movem o tornozelo e a coluna lombar, sobre o limiar de dor à pressão, sobre a flexibilidade e sobre a assimetria dos músculos paravertebrais lombares ao nível de L5. Vinte voluntários foram divididos aleatoriamente em grupo experimental (n=10), em que os voluntários receberam manipulação na articulação sacroilíaca e transição lombossacral e grupo placebo (n=10), em que os voluntários receberam manobra sem efeitos terapêuticos. Foi realizada avaliação eletromiográfica dos músculos paravertebrais lombares ao nível de L5, do tibial anterior e fibular longo homolaterais ao tornozelo instável. Foi realizado teste de dor à pressão com algômetro no processo espinhoso de L5, tubérculo de S1, cabeça da fíbula e maléolo lateral, bilateralmente e foram realizados testes de flexibilidade com banco de Wells, teste de Schober, teste de Stibor e teste de elevação do membro inferior estendido. Foram encontrados, na análise intragrupo, para o GE, na condição de isometria dos paravertebrais, aumento significativo da simetria entre os paravertebrais direitos e esquerdos na comparação entre os períodos pré intervenção e pós tardio (p= 0,03) e na comparação entre os períodos pós imediato e pós tadio (p= 0,04) e efeitos moderados da técnica sobre o sinal elétrico de músculos estudados, porém não houve alteração na flexibilidade e na algometria. O aumento da simetria entre os paravertebrais ocorreu, provavelmente, por dois efeitos da manipulação. Houve estímulo dos mecanorreceptores articulares, que, via neurológica, podem melhorar o controle motor dos músculos inervados pelo nível manipulado e provavelmente houve melhora postural dos voluntários, o que pode gerar diminuição das assimetrias dos músculos posturais. Conclui-se que a manipulação aumentou a simetria dos paravertebrais lombares, alterou o sinal elétrico de músculos estudados, não melhorou a flexibilidade e não alterou a algometria em indivíduos que apresentam instabilidade do tornozelo / Abstract: Joint manipulation has been used in physical therapy to increase joint mobility and generate reflexive responses for a consequent reduction in pain and improvement in motor control and flexibility. Individuals with ankle instability exhibit altered motor control in the lower limb ipsilateral to the unstable ankle as well as altered postural control, which can affect the symmetry of postural muscles. The aim of these three studies was to evaluate the effect of the manipulation of the sacroiliac joint and lumbosacral transition on electrical activity in the muscles that move the ankle and lumbar spine, the pain pressure threshold, flexibility and asymmetry of the lumbar paravertebral muscles at L5. Twenty volunteers were allocated to either an experimental group (n = 10), which was submitted to manipulation of the sacroiliac joint and lumbosacral transition, or a control group (n = 10), which was submitted to a maneuver with no therapeutic effect. Electromyographic evaluations were performed of the L5 paravertebral, tibialis anterior and fibularis longus muscles ipsilateral to the unstable ankle. The pressure pain threshold was determined using an algometer over the L5 spinous process, S1 tubercle, head of the fibula and lateral malleolus bilaterally. Flexibility was determined with the Wells battery of tests, Schober test, Stibor test and elevation of the extended lower limb. Moderate effect size were found in the electromyographic signal of two muscles studied, no significant changes were found on flexibility or algometry. In the intra-group analysis, however, a significant increase in the symmetry of the right and left paravertebral muscles was found in the experimental group during isometric contraction between the pre-intervention and late post-intervention evaluations (p = 0.03) as well as between the immediate post-intervention and late post-intervention evaluations (p = 0.04). This increase in symmetry in the paravertebral muscles likely occurred due to two effects of manipulation: 1) the stimulus of joint mechanoreceptors, which improved the motor control of the innervated muscles at the level manipulated through the neurological pathway; and 2) an improvement in posture, which led to a reduction in the asymmetry of the postural muscles. In conclusion, manipulation of the sacroiliac joint and lombosacral transition led to an improvement in the symmetry of lumbar paravertebral muscles in individuals with ankle instability, alters the electromyographic signal of two muscles studied, but exerted no effects on flexibility or the pressure pain threshold / Doutorado / Anatomia / Doutor em Biologia Buco-Dental
|
148 |
Caracterização multifatorial de uma população de portadores de desordens temporomandibularesOliveira, Anamaria Siriani de 04 September 2002 (has links)
Orientador : Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T09:47:12Z (GMT). No. of bitstreams: 1
Oliveira_AnamariaSirianide_D.pdf: 3982282 bytes, checksum: d15affaaab83aa187198342d34706fb1 (MD5)
Previous issue date: 2002 / Resumo: A presente pesquisa teve por objetivo descrever os achados clínicos mais comuns do índice clínico diagnóstico, ficha de avaliação fisioterápica, questionário de dor e exame eletromiográfico, de pacientes portadores de DTM:, da cidade de Araraquara e região. Para tanto, trabalho foi selecionado um grupo de 23 pacientes, sendo 21 mulheres e 2 homens, com faixa etária entre 17 a 55 anos de idade (média de 28 anos :t11), da cidade de Araraquara e região, que procuraram
a Clínica de Fisioterapia UNIARA para atendimento fisioterápico em um período de 14 meses. À todos os voluntários foram esclarecidos os objetivos da pesquisa e solicitado o preenchimento do consentimento formal de participação. Foram utilizados o questionário do índice clínico de FONSECA (1992) e para avaliação da dor o Br-MPQ, seguidos da realização da avaliação fisioterápica e exame eletromiográfico. Para o registro eletromiográfico foram utilizados: (1) Módulo
Condicionador de Sinais com 12 bites de resolução de faixa dinâmica filtro do tipo Butterworth, de passa-baixa de 509 Hz e passa-alta de 10,6 Hz e ganho de 50 vezes; (2) placa conversora A/D de 12 bites e amostragem de 1000 Hz e (3) software para registro e armazenagem dos sinais. Todos os pacientes foram classificados como portadores de desordem temporomandibular do tipo severa (n=15) ou moderada (n=8), sendo que os resultados dos achados da ficha de avaliação, questionário de dor e variáveis eletromiográficas foram comparados entre estes dois grupos. A avaliação fisioterápica revelou, para ambos os grupos de pacientes, elevada presença de hábitos parafuncionais combinados, desvios do alinhamento da coluna cervical, pontos gatilhos nas regiões da cintura escapular e cervical, alterações do trofismo da musculatura da face e presença de ruídos articulares. Os valores da amplitude de movimento mandibular obtidos mostraram algum grau de restrição, independente do grau de severidade dos grupos estudados. No grupo de DTM: severa a região dolorosa mais indicada pelos portadores foi sobre a ATM, enquanto que o grupo de DTM moderada indicou mais freqüentemente a região cervical. Entre os músculos da mastigação, o temporal foi o mais indicado como área de dor, por ambos os grupos. Para o padrão temporal da dor, 50% dos pacientes do grupo com DTM moderada anotaram que suas queixas tinham uma característica ritmada, periódica, intermitente. No grupo com DTM severa a anotação mais freqüente foram contínua, estável, constante. A análise do PPI no momento da avaliação revelou que o grupo DTM severa concentrou seus índices em níveis de intensidade menores que aqueles do grupo DTM moderada. Os valores médios dos PRIs ponderados em cada uma das dimensões da dor escolhidos por ambos os grupos foram similares e os valores da dimensão de palavras mistas foram
discretamente maiores. Os valores de amplitude, coeficientes de variação dos envoltórios lineares, freqüências medianas e coeficientes de inclinação da reta do espectrograma não mostraram nenhuma diferença significativa (p>0.05) dependente da severidade da desordem temporomandibular quanto comparada através do teste de Mann-Witney. Por fim, nestas condições esperimentais, concluiu-se que requisitos de inclusão de pacientes em pesquisas clínicas devem seguir avaliações criteriosas e conter o maior número possível de informações sobre a amostra, uma vez que, um grande número de sinais e
sintomas podem estar associados no quadro clínico de um portador de desordem temporomandibular / Abstract: Not informed. / Doutorado / Doutor em Biologia Buco-Dental
|
149 |
Analise eletromiografica do musculo orbicular do olho em pacientes portadores de protese ocular antes e apos a instalação proteicaRegalo, Simone Cecilio Hallak 07 June 2000 (has links)
Orientador : Mathias Vitti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T15:08:40Z (GMT). No. of bitstreams: 1
Regalo_SimoneCecilioHallak_M.pdf: 5418943 bytes, checksum: 74c2c0355f69e4d09e59c615b8f044d1 (MD5)
Previous issue date: 2000 / Resumo: Além da função primária de proteção das cavidades da face, os músculos cutâneos são de suma importância na estética e na expressão facial para o homem. São músculos que se apresentam localizados superficialmente na face e seus estudos eletromiográficos têm contribuído para sua melhor descrição. O objetivo do presente trabalho é o de analisar comparativamente por meio de exame eletromiográfico o músculo orbicular do olho de pacientes controles e pacientes com indicação para receber prótese ocular (pacientes tratados). Para este trabalho foram estudados o músculo orbicular do olho de 24 pacientes do sexo masculino, com a idade média de 32,5 anos, que foram divididos em dois grupos: o primeiro grupo formado por 12 pacientes portadores de problemas oculares do lado esquerdo (ausência do globo ocular esquerdo), com indicação para receber prótese ocular, o segundo grupo formado por: 12 pacientes controles. Todos os pacientes indicados para receber prótese ocular tiveram perda do globo ocular causada por diferentes tipos de acidentes como: explosivos, projéteis, bola, farpas de madeira e acidente de trânsito, exceto um, que teve toxoplasmose, mas foram todos considerados normais na anamnese física e psicológica. Os exames foram realizados com o Eletromiógrafo K6-I EMG Light Channel Surface Electromyography (Myo-tronics CO. Seattle, WA, EUA) de oito canais. Diante dos resultados encontrados, nas condições do presente trabalho, é lícito concluir que: 1. O uso da prótese ocular melhora as condições estéticas do paciente mutilado de face. 2. A perda do globo ocular, leva a um aumento da atividade eletromiográfica do músculo orbicular do olho. 3. O uso da prótese ocular, por um período de tempo de 7 dias ( uma semana), não foi suficiente para diminuir esta atividade muscular, mesmo constatando-se clinicamente, perfeita adaptação da prótese. 4. O uso da prótese ocular não interferiu na condição clínica de Abertura e Fechamento Forçado da Pálpebra (A/FF) / Abstract: Besides the primary function of protecting the facial cavities, the cutaneous muscles are of paramount importance concerning esthetics and facial expression of the human being. They are muscles superficially localized in the face and the electromyographic studies have contributed a lot for their better description. The aim of this study was to comparatively analyze through electromyographic examination the orbicular muscle of normal subjects and of patients indicated to receive ocular prosthesis. In this investigation the orbicular muscles of 24 male subjects were studied. Their mean age was 32.5 years and they were allocated into two groups as follows: The first group was made up by: 12 patients with ocular problems in the left side (absence of the left eyeball) indicating an ocular prosthesis. The second group was formed by: 12 normal subjects. All the patients indicated for ocular prosthesis had lost their eyeballs due to different kinds of accidents as: explosives, projectiles, balls, wooden splinters and traffic accidents, the exception being one who had toxoplasmosis. Notwithstanding, all of them were considered normal in the physical and psychological anamnesis. The determinations were carried out using the eight channel Electromyograph K6-I - Light Channel Surface Electromyography (Myotronic CO. Seattle, W A, USA). Considering the results found under the conditions of this study, we may conclude that: 1. The use of the ocular prosthesis improves the esthetic condition of patients mutilated in the face. 2. The loss of the eyeball increases the orbicular muscle electromyographic activity. 3. The use of the ocular prosthesis during 7 days (one week) has not been sufficient to diminish this muscular activity, even when a perfect adaptation of the prosthesis has been clinically observed. 4. The use of the ocular prosthesis did not interfere with the Forced Opening and Closure of the Eyelids (AJFF) clinical condition / Mestrado / Mestre em Biologia e Patologia Buco-Dental
|
150 |
Características da mastigação, força de mordida e atividade elétrica dos músculos masseteres em laringectomizadosKarla Bezerra Oliveira Nascimento, Gerlane 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T22:59:50Z (GMT). No. of bitstreams: 2
arquivo2821_1.pdf: 3583064 bytes, checksum: 6e2dc953c2a19f763c10bc12f7dc3610 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Introdução: O câncer de laringe é um dos mais comuns a atingir a região de cabeça e
pescoço, representando cerca de 25% dos tumores malignos que acometem esta área e 2% de
todas as doenças, estando associado ao tabagismo e/ou etilismo. O tratamento indicado nos
casos mais avançados dessa patologia é a laringectomia total, resultando na perda da voz
laríngea e modificações anatômicas da região cervical. A laringectomia total promove
mutilações que geram mudanças nos padrões morfofisiológicos, fazendo com que o
laringectomizado seja submetido a adaptações, acomodações e compensações da musculatura
envolvida na força de mordida, mastigação e amplitude de movimento do complexo articular
da mandíbula. Objetivo: Caracterizar o lado de preferência mastigatória e força de mordida
em laringectomizados totais e observar se existe relação com a atividade elétrica do músculo
masseter e a simetria facial. Método: A coleta de dados foi realizada no setor de
Fonoaudiologia do Hospital de Câncer de Pernambuco (HCP) entre fevereiro e junho de 2010,
e contou com a participação de quinze voluntários laringectomizados totais do gênero
masculino com idade média de 64 anos. Para a verificação da força de mordida solicitou-se a
execução da máxima intercuspidação habitual em célula de carga com duração de cinco
segundos cada uma e intervalos de dez segundos entre elas para repouso. A célula esteve
localizada entre os incisivos centrais e pré-molares dos lados direito e esquerdo das arcadas
dentárias em momentos distintos para cada posição; a avaliação da mastigação constou da
filmagem do ato mastigatório de forma habitual, com finalidade de se identificar o lado de
preferência mastigatória; a avaliação da atividade elétrica foi realizada por meio de registros
eletromiográficos dos músculos masseteres direito e esquerdo, durante os momentos de
contração voluntária máxima e na função de mastigação habitual e unilateral (direita e
esquerda). Valores da antropometria facial foram averiguados para otimizar as correlações das
variáveis. Com auxílio de um paquímetro digital as distâncias entre os pontos ex (canto
externo da fissura palpebral) e ch (cheilion) nas duas hemifaces foram obtidas. Resultados:
Na análise dos dados foram obtidas as medidas estatísticas: média, mediana e desvio padrão e
o coeficiente de correlação de Pearson. O programa utilizado para a digitação dos dados e
obtenção dos cálculos estatísticos foi o SPSS (Statistical Package for the Social Sciences) na
versão 15. Em 46,7% dos voluntários houve preferência mastigatória no lado direito e em
53,3% deles a preferência foi do lado esquerdo. As médias das distâncias entre os pontos ex e
ch foram 68,48mm no lado direito e 68,93mm no lado esquerdo. Os valores de força
encontrados durante a incisão apresentaram média de 25,77 Kgf. Nas mordidas unilaterais
direita e esquerda em região de molares os valores médios encontrados foram 23,53 Kgf e
30,54Kgf, respectivamente. O maior valor das correlações entre a força de mordida do lado
direito e esquerdo e as atividades elétricas durante as etapas de mastigação foi igual a 0,207
(p= 0,459) e 0,362 (p= 0,185), respectivamente. Conclusão: Há diferença significativa entre
os valores percentuais de atividade elétrica do masseter direito em relação ao esquerdo
durante a mastigação unilateral direita. Há relação estatisticamente comprovada entre o lado
de preferência mastigatória e o lado da face com menor medida antropométrica. O lado de
preferência da mastigação parece não relacionar-se com o lado da maior atividade elétrica na
mastigação. Ao associar os valores de atividade elétrica dos masseteres com a força de
mordida, não foram evidenciadas correlações significativas
|
Page generated in 0.0496 seconds